11

Étude expérimentale du transport des aérosols dans un espace clos ventilé et impact des principales stratégies d'épuration microbiologique de l'air sur l'exposition des occupants

Delaby, Stéphane 09 July 2008 (has links)
L’exposition aux aérosols microbiologiques présents dans les environnements clos est susceptible de provoquer, chez les occupants, diverses pathologies telles que des infections, des toxi-infections et des allergies. Pour s’en prémunir, diverses stratégies passant notamment par l’emploi de dispositifs épurateurs d’air, ont été développées et commercialisées par les industriels de la ventilation et du traitement de l’air. Cependant, à ce jour, aucune méthodologie d’évaluation y compris normative ne permet d’évaluer la pertinence de ces stratégies. Ce travail de recherche se propose, d’une part, d’appréhender le devenir des aérosols microbiologiques au sein des espaces clos : de la source à l’individu exposé, en explorant le rôle de la ventilation dans ce transport et, d’autre part, d’explorer le gain apporté par les nouvelles technologies de traitement microbiologique de l’air sur l’exposition des occupants. Pour ce dernier point de l’étude, une démarche globale d’évaluation en 3 volets a été adoptée avec l’étude de l’efficacité du ou des principes d’épuration mis en oeuvre, la détermination du rendement intrinsèque en condition dynamique de ces systèmes et l’évaluation du gain apporté par ces derniers sur l’exposition des occupants. Les travaux menés avec les dispositifs épurateurs (filtration et photocatalyse) ont montré que les efficacités intrinsèques des systèmes ne permettent pas de préjuger de leur gain vis-à-vis du niveau de l’exposition des individus lorsqu’ils sont mis en oeuvre en environnement intérieur. Les résultats obtenus ont également mis en évidence que la prise en compte des flux aérauliques et du transport des particules induit par la ventilation et le dispositif épurateur est indispensable à la définition d’une stratégie cohérente de traitement d’air / Exposure to bioaerosols in indoor environments is associated with a wide range of adverse effects on health including infectious diseases, acute toxic effects and allergies. In order to guard against this phenomenon, the ventilation and air treatment industry has developed and marketed many air control strategies. However, at present, there is no methodology adapted to the evaluation of the relevance of these strategies. The aim of this research work was to characterize, in a first time, the progress of microbiological aerosol from the original source, to their eventual inhalation by person exposed, considering their dissemination through the indoor environments. Secondly, the work consisted of determining the efficiency of air cleaner devices applied to control indoor air quality. For this point, a global approach of evaluation in 3 steps was adopted, consisting of studying the efficiency of the epuration principle implemented, determining the intrinsic performance of the systems in dynamic conditions and their impact on the exposure level of the exposed persons. The tests carried out with air cleaner devices (filtration and photocatalysis) have shown that the intrinsic performance wasn’t able to estimate the beneficial impact of these systems on the exposure level of people when there were applied in indoor environments. So the intrinsic performance of devices is not the single impact factor, the airflow promoted by the device is also a factor to consider. Moreover, the characterization of indoor airflows and airborne particles transport is essential to define a coherent strategy of air treatment
12

Estudo da melhoria do desempenho de sistemas de resfriamento evaporativo por micro aspersão de água / Study of improvement the evaporative cooling system performance by water misting systems

Zapaterra, Cássio Luiz Ianni 29 September 2016 (has links)
Disponibilidade dos recursos energéticos junto com o despertar da consciência ambiental criaram um interesse por uma condição climática sensível compatível com os recursos disponíveis. Dentro desse cenário o trabalho se volta à necessidade de se criarem e manterem ambientes industriais termicamente adequados aos processos de produção para minimizar as interferências que as condições ambientais exercem sobre os custos dos processos de produtivos e sobre o consumo energético. Os sistemas de resfriamento evaporativo, por sua vez, têm sido a ferramenta de maior potencial de aplicação na criação de ambientes termicamente adequados aos processos. Este modelo revisto de conforto térmico nos coloca um passo à frente para o aumento eficiência energética na construção de projeto de climatização vinculados a temperaturas interiores que atendam conjuntamente tanto aos ocupantes como às atividades que desenvolvem no interior da área climatizada. Apesar de esse sistema apresentar vantagens operacionais, quando comparado a outros sistemas convencionais, existem certas limitações no seu desempenho. Uma das maiores dificuldades das instalações destes sistemas reside na existência de incertezas em qualquer resultado. Possibilitar um controle dos parâmetros, minimizando os erros de aplicação, evitando criar no ambiente um desconforto de tal grau que inviabilize sua aplicação, é o fundamento deste trabalho. A busca passa a ser pela garantia da aceitabilidade dos resultados do sistema projetado e seus limites de aplicabilidade. O estudo das variáveis que interferem no processo do resfriamento por micro aspersão permitiu desenvolver um processo que alterara esses parâmetros durante o funcionamento do sistema, interferindo, conforme a necessidade no seu desempenho, garantindo a completa evaporação da água micro aspergida. / Energy resources along with an environmental conscience awakening has created an interest in sensitive climate together with a more understanding regarding the use of available resources. Inside this scenario our work focus on the needs of creating and maintaining industrial environments thermally suited to these production processes that seeking to minimize interference that environmental conditions have on the costs of production processes and energy consumption. Evaporative cooling systems, in turn, has been a interesting tool to be used in the creation of thermally suitable environments to these processes. This new revised thermal comfort model puts us a step forward to increase energy efficiency in elaborating air treatment projects linked to indoor temperatures that meet both the occupants and the activities that develop inside the controlled area. Although this system has operational advantages when compared to other conventional systems, there are some limitations in their performance. A major difficulty of the installation envolving these systems is about the existence of uncertainty in any results. To allow the control of these parameters in order to minimize the errors in this kind of application and to avoid creating environmental discomfort to such a degree that prevent the implementation, it is the foundation of this work. The search is to ensure the acceptability of the results of the system designed and their limits of applicability. The study of the variables that affect the cooling process by misting allowed us to develop a process that altered these parameters during operation of the system, interfering, as required in its performance, ensuring complete evaporation of water applied by misting in the area.
13

Conception, développement et caractérisation de microréacteurs pour la dégradation des composés organiques volatils par oxydation catalytique sur platine : application à l’acétone, à la méthyléthylcétone et au toluène / Design, development and characterization of microreactors for Volatile Organic Compounds abatement by catalytic oxidation over platinum : application to acetone, methyl-ethyl-ketone and toluene

Rachedi, Fahima 24 March 2014 (has links)
Durant ces dernières années les contraintes environnementales, au niveau national et international, obligent les industriels à maitriser leurs rejets d’effluents liquides et gazeux notamment leurs émissions de Composés Organiques Volatils (COV). Les COV sont des composés dangereux pour la santé de l’homme et pour son environnement à cause de leur persistance dans l’air et de leur capacité à se transformer en d’autres molécules encore plus dangereuses. Ils sont également classés comme gaz à effet de serre directs et indirects (précurseurs d’ozone). L’oxydation catalytique est un procédé destructif très intéressant et largement employé pour l’élimination des COV, il présente plusieurs avantages telles qu’une conversion élevée et une grande sélectivité par rapport au CO2. De plus, les températures de fonctionnement sont très modérées par rapport à la combustion thermique. Cependant, cette réaction fortement exothermique, extrêmement rapide, est généralement mise en œuvre dans des réacteurs à lits fixes conventionnels, et se déroule en présence de fortes limitations par le transfert de matière. Ce procédé est donc très demandeur en termes de conception de nouveaux réacteurs qui peuvent permettre d’intensifier les transferts pour atteindre l’efficacité requise au moindre coût. Les travaux présentés dans ce manuscrit concernent ainsi la conception et le développement de microréacteurs pour la dégradation des COV, trois molécules ont été étudiées : l’acétone, la méthyléthylcétone et le toluène. Les microréacteurs développés dans cette étude sont des réacteurs microstructurés à multiples canaux parallèles, basés sur le principe d’empilement de plaques en silicium recouvertes du catalyseur (platine). Les microréacteurs possèdent de part leurs dimensions micrométriques, des ratios S/V très élevés par rapport aux réacteurs conventionnels. Les ratios S/V des quatre microréacteurs, conçus dans ces travaux, varient de 14000 à 60000 m2/m3 alors qu’à titre d’exemple, la cuve agitée possède des ratios de 100-1000 m2/m3. Les microréacteurs étudiés se distinguent par leur conception. Les microréacteurs de 1re génération, dont le chauffage se fait par conduction avec des cartouches résistives insérées dans une enceinte métallique (acier INOX), se différencient par les dimensions de leurs microcanaux (200x500, 200x100 et 100x50 µm2). L’originalité du microréacteur de 2e génération (200x100 µm2) est liée à son système d’alimentation mais surtout à son mode de chauffage intégré constitué d’une plaque en silicium, comportant résistance et capteurs de température, insérée au milieu des plaques catalytiques. Les résultats obtenus en termes de performance catalytique sont très prometteurs (65-100 % de conversion) sur une large gamme de concentration des COV (250-11700 ppmV) et des GHSV très élevées (18700-314000 h-1). Il a également été constaté que, outre la température, les conditions opératoires (GHSV et concentration) avaient une influence importante sur les performances catalytiques. Le microréacteur de 2e génération a conduit à de meilleures conversions que les microréacteurs de 1re génération, en particulier aux températures élevées. Un ordre de réactivité entre les molécules qui dépend de leurs concentrations a également été établi. Concernant la caractérisation des écoulements dans les microréacteurs, les écoulements observés sont laminaires dans les microcanaux et les écoulements dans les microréacteurs correspondent probablement à un modèle piston à dispersion axiale malgré des valeurs du nombre de Bodenstein trés élevées. La continuité du milieu fluide a été étudiée dans les microréacteurs et un éventuel effet de raréfaction a été relevé dans le plus petit réacteur (100x50 µm2). Finalement, une étude des limitations par le transfert de matière a permis d’écarter d’éventuelles limitations dues au transfert de matière interne et de mettre en évidence la difficulté d’évaluer les limitations par le transfert de matière externe. / During last years the environmental constraints applied at national and international level, have led the manufacturers to control their pollutants released into atmosphere especially the Volatiles Organic Compounds (VOCs). The VOCs are harmful to human health and environment because of their persistence in air and their ability to be transformed to more dangerous molecules. They are also recognized as direct and indirect greenhouse gases as ozone precursors. Catalytic oxidation is a very interesting destructive process for VOCs removal. It presents a lot of advantages like high combustion efficiency (high conversion and CO2 selectivity). Furthermore, this process occurs at lower temperatures than the combustion. However, this very exothermic and very fast reaction, generally implemented in conventional fixed bed reactors exhibits strong mass transfer limitations. This process is consequently very demanding in terms of design of reactors with transfer intensification ability in order to achieve the required efficiency as well as lower the costs of the process. The present research works concern the design and the development of microreactors for VOCs removal and three molecules were tested: acetone, methyl-ethyl-ketone and toluene. The microreactors developed in this study, are parallel multichannel structured reactors, based on stacking of silicon platelets coated by the catalyst (platinum). The micrometric dimensions confer to microreactors much higher S/V ratios than conventional reactors with an important potential of transfer intensification as a consequence. The four microreactors exhibit S/V ratios with a range of 14000 to 60000 m2/m3, in comparison the S/V ratios of the stirred tank do not exceed 1000 m2/m3. These microreactors are distinguished in terms of design as 1st and 2nd generation reactors. The 1st generation ones present the same stainless steel housing equipped with four resistive cartridge heaters but the microchannels dimensions are different (200x500, 200x100 and 100x50 μm2). The 2nd generation microreactor (200x100 μm2) has the particularity to integrate platinum electrical heating resistance and sensors between the catalytic platelets. The results of the study in terms of catalytic performances are very promising (65 to 100 % of conversion) in a large scale of VOCs concentration (250-11700 Vppm) and very high space velocities (18700-314000 h-1). It was observed that not only temperature but also experimental parameters (GHSV and concentration) have an important effect on catalytic performances. However, it was shown that the 2nd generation microreactor is more efficient than the 1st generation ones in particular at high temperatures. An order of molecules reactivity was also established according to their concentrations. Regarding the gas flow in the microreactors, the flow laminarity in microchannels has been confirmed and the flow through the microreactors follows probably a plug-flow axial-dispersion model in spite of high Bodenstein numbers. The continuity of the gas flow was also investigated and an eventual rarefaction effect was noticed on the smallest microreactor (100x50 μm2). Finally, a transfer limitation study allowed dismissing the control of the reaction by internal diffusion and highlighted difficulties to evaluate the external mass transfer limitations.
14

Estudo da melhoria do desempenho de sistemas de resfriamento evaporativo por micro aspersão de água / Study of improvement the evaporative cooling system performance by water misting systems

Cássio Luiz Ianni Zapaterra 29 September 2016 (has links)
Disponibilidade dos recursos energéticos junto com o despertar da consciência ambiental criaram um interesse por uma condição climática sensível compatível com os recursos disponíveis. Dentro desse cenário o trabalho se volta à necessidade de se criarem e manterem ambientes industriais termicamente adequados aos processos de produção para minimizar as interferências que as condições ambientais exercem sobre os custos dos processos de produtivos e sobre o consumo energético. Os sistemas de resfriamento evaporativo, por sua vez, têm sido a ferramenta de maior potencial de aplicação na criação de ambientes termicamente adequados aos processos. Este modelo revisto de conforto térmico nos coloca um passo à frente para o aumento eficiência energética na construção de projeto de climatização vinculados a temperaturas interiores que atendam conjuntamente tanto aos ocupantes como às atividades que desenvolvem no interior da área climatizada. Apesar de esse sistema apresentar vantagens operacionais, quando comparado a outros sistemas convencionais, existem certas limitações no seu desempenho. Uma das maiores dificuldades das instalações destes sistemas reside na existência de incertezas em qualquer resultado. Possibilitar um controle dos parâmetros, minimizando os erros de aplicação, evitando criar no ambiente um desconforto de tal grau que inviabilize sua aplicação, é o fundamento deste trabalho. A busca passa a ser pela garantia da aceitabilidade dos resultados do sistema projetado e seus limites de aplicabilidade. O estudo das variáveis que interferem no processo do resfriamento por micro aspersão permitiu desenvolver um processo que alterara esses parâmetros durante o funcionamento do sistema, interferindo, conforme a necessidade no seu desempenho, garantindo a completa evaporação da água micro aspergida. / Energy resources along with an environmental conscience awakening has created an interest in sensitive climate together with a more understanding regarding the use of available resources. Inside this scenario our work focus on the needs of creating and maintaining industrial environments thermally suited to these production processes that seeking to minimize interference that environmental conditions have on the costs of production processes and energy consumption. Evaporative cooling systems, in turn, has been a interesting tool to be used in the creation of thermally suitable environments to these processes. This new revised thermal comfort model puts us a step forward to increase energy efficiency in elaborating air treatment projects linked to indoor temperatures that meet both the occupants and the activities that develop inside the controlled area. Although this system has operational advantages when compared to other conventional systems, there are some limitations in their performance. A major difficulty of the installation envolving these systems is about the existence of uncertainty in any results. To allow the control of these parameters in order to minimize the errors in this kind of application and to avoid creating environmental discomfort to such a degree that prevent the implementation, it is the foundation of this work. The search is to ensure the acceptability of the results of the system designed and their limits of applicability. The study of the variables that affect the cooling process by misting allowed us to develop a process that altered these parameters during operation of the system, interfering, as required in its performance, ensuring complete evaporation of water applied by misting in the area.
15

Perception et confort acoustiques des systèmes de traitement d'air / Acoustic perception and comfort of air-treatment systems

Minard, Antoine 26 March 2013 (has links)
Cette thèse a pour but d’étudier le confort acoustique ressenti par les usagers de systèmes de traitement d’air (STA), tels que les systèmes de climatisation installés en bureaux de différentes tailles, en prenant en compte les facteurs environnementaux liés au contexte particulier d’usage de ces produits. À l’origine s’est présenté le besoin industriel d’une norme fiable d’évaluation des sons émis par les STA, pour offrir une représentation plus fidèle de la perception que le seul standard existant aujourd’hui : le niveau acoustique émis exprimé en dBA. Ce contexte impose en premier lieu une étude approfondie de la perception des sons de STA tels qu’émis par les appareils. Ainsi, une démarche rigoureuse a été suivie allant du recueil d’un nombre conséquent d’enregistrements de sons de STA jusqu’à l’établissement d’une métrique robuste de prédiction de la qualité sonore perçue. Pour ce faire, ont tout d’abord été établies les différentes familles perceptives qui constituent l’ensemble des enregistrements de sons de STA effectués. De cet ensemble de familles a été extrait un corpus de travail permettant une complète représentativité des différents types de sons émis par les STA. Les attributs auditifs pertinents pour la description perceptive de ce corpus sonore ont ensuite été identifiés en appliquant les principes de l’étude du timbre musical, déjà adoptés avec succès pour la description d’autres types de sons de l’environnement. Ces attributs auditifs ont enfin servi de base descriptive pour expliquer les préférences des auditeurs vis-à-vis des sons de STA afin d’établir un prédicteur efficace de la qualité sonore à l’aide de descripteurs audio. Dans un second temps, afin de prendre en considération le contexte écologique des STA, l’influence de deux facteurs environnementaux sur l’évaluation de la qualité sonore des STA a été étudiée dans le but d’en évaluer l’importance sur le ressenti des usagers. D’une part, comme les STA étudiés sont des appareils exclusivement installés en intérieur (bureaux), l’effet de la réverbération sur l’évaluation de la qualité sonore a été étudié à l’aide d’un système d’auralisation permettant de reproduire virtuellement la réponse acoustique d’une salle. D’autre part, l’influence du contexte attentionnel des auditeurs sur la qualité sonore perçue a été évaluée à l’aide d’une étude comparative de différentes situations d’écoute. En effet, on observe que la perception du son émis par les STA se traduit typiquement par une forme de perturbation de leur occupation quotidienne.. Il est donc apparu pertinent d’évaluer à quel point le degré d’attention portée sur le son influe sur l’évaluation de la qualité sonore par les auditeurs. Ainsi nous avons pu établir dans quelles mesures et selon quelles limites le prédicteur de qualité sonore établi peut représenter fidèlement le confort ressenti par les usagers dans un contexte offrant un meilleur degré de validité écologique que les conditions habituelles de laboratoire. / This thesis addresses the perceived acoustic comfort of Air-Treatment Systems (ATS), such as air-conditioners installed in offices, by taking into account the environmental factors related to the specific context of ATS usage. The only existing standard to evaluate the sounds emitted by ATS, which is the emitted sound level in dBA, is only loosely related to perception. Therefore, the need of manufacturers for a more reliable standard arises. This implies a thorough study of the perception of the sound of ATS as it is emitted. A precise methodology was then followed: it includes first collecting a high number of ATS sound recordings, up to finally developing a robust metrics to predict the perceived sound quality. For that purpose, different perceptual categories were first identified to constitute the recording database of ATS sounds. A corpus considered as fully representative of the different types of emitted sounds was then extracted from the recording database. Current principles of musical timbre description have already proved to be adequate to other types of environmental sounds; by applying these principles, the relevant auditive attributes for the corpus perceptual description were identified. In order to develop an efficient sound quality predictor through audio features calculation, prominent features based on these auditive attributes were identified that explain the listeners’ preferences among ATS sounds. The ecological context of ATS was examined in a second step. Two environmental factors were addressed in the context of ATS sound quality evaluation to ponder their importance in the listeners’ perception. As the ATS under study are exclusively indoor systems designed for offices, the effect of reverberation on sound quality evaluation was first studied; for that purpose, an auralization tool was used to simulate room acoustic response. The influence of listeners’ attention context on perceived sound quality was then evaluated through a comparative study of various listening conditions. As a matter of fact, the sound emitted by ATS in real conditions is perceived as a perturbation of current activities. It is therefore relevant to evaluate how deeply the degree of attention related to the sound affects listeners as regards their perception of acoustic quality. Eventually, the relevance of the proposed sound quality predictor to comfort perception was assessed in conditions more ecologically representative than usual laboratory environment.
16

Développement de nouveaux solvants de lavage pour l'absorption des Composés Organiques Volatils / Development of new solvents for Volatile Organic Compounds' absorption

Moufawad, Tarek 19 November 2019 (has links)
L(objectif de cette thèse a été de développer de nouveaux solvants d'absorption des composés organiques volatils (COV). Ces derniers sont des polluants atmosphériques primaires généralement utilisés comme solvants et émis directement par les industries. Ils induisent des effets nocifs pour la santé, et certains d'entre eux, sont classés comme cancérogènes. La réduction des émissions de ces polluants reste donc une préoccupation majeure. L'objectif de notre travail a été d'évaluer les solvants eutectiques profonds (DES) comme absorbants pour les COV. Les DES représentent une nouvelle génération de solvants. Ils sont formés par simple mélange de 2 ou plusieurs composés. Ils peuvent être produits à partir de composés économiques, naturels et biodégradables. La préparation de ces solvants est facile et permet une économie d'atome de 100%. Le travail a été divisé en trois parties.La première partie a été consacrée à la caractérisation des propriétés physico-chimiques des DES, telles que la densité et la viscosité. L'analyse des spectres infrarouge des DES et de leurs composés purs a montré une implication des liaisons hydrogène dans la formation des DES. La polarité a été étudiée à l'aide de la sonde Nile red. Enfin, la solubilité de gaz (CO₂, CH₄ and Ar) a été mesurée dans les DES en fonction de la température. La deuxième partie a porté sur l'évaluation de la capacité d'absorption des DES en utilisant la technique d'headspace statique couplée à la chromatographie en phase gazeuse. Ceci nous a permis de déterminer le coefficient de partage gaz/liquide pour les COV dans les DES à différentes températures. L'influence des mélanges de COV sur les capacités d'absorption des DES a été également déterminée. Ces derniers ont montré des capacités d'absorption élevées pour la variété de COV, sans saturation même à forte concentration. Un nouveau système DES-cyclodextrine a également été évalué. Les capacités d'absorption ont été améliorées grâce au rôle de molécule cage de la cyclodextrine. La deuxième partie a été tournée vers l'application industrielle. Nous avons évalué les capacités d'absorption des DES à l'aide d'un montage dynamique qui simule une colonne d'absorption industrielle. Cette installation permet de moduler le débit du COV, les teneurs en eau ainsi que la température de la colonne. Enfin, la régénération des DES a été effectuée par plusieurs cycles absorption/désorption sans perte de capacité d'absorption. En conclusion, l'ensemble des résultats obtenus a montré que les DES possédaient de nombreux atouts leur permettant d'être considérés comme des solvants prometteurs pour l'absorption des COV. / The aim of this thesis was to develop new solvents for the absorption of volatile organic compounds (VOC). VOC are primary air pollutants generally used as solvents and emitted directly from industries. They have adverse health effects and some of them are classified as carcinogenic. Consequently, the reduction of the emissions of these pollutants remains a major challenge to reduce air pollution. Hence, our objective was to evaluate deep eutectic solvants (DES) as absorbents for VOCs. DESs represent a new generation of solvents that is formed by simply mixing two or more compounds. They can be produced from cheap, natural and biodegradable compounds. The preparation of these solvents is easy and is 100% atom efficient. This work was divided into three parts.The first part focused on the physicochemical properties of DES, such as density and viscosity. Analysis of the infrared spectra of DES and their pure compounds showed that hydrogen bonds are essential for the formation of DES. Their polarity was studied using the Nile red probe. In addition, solubility of various gases (CO₂, CH₄ and Ar) was measured as a function of temperature. The second part dealt with the evaluation of the aborsption capacity of DESs using static headspace coupled with gas chromatography. The determination of gas/liquid partition coefficient was performed for various VOC and DES at different temperatures. In addition, the influence of VOC mixtures on DES absorption capacities was determined. DES showed high absorption capacities for a variety of VOCs, without saturation even at high concentration. A new DES-cyclodextrin system was developed and showed improved absorption capacities due to the complexation ability of the cyclodextrin. The last part was oriented towards the industrial application of DESs. The absorption capacities of DESs were evaluated using a dynamic set-up which simulated an industrial absorption column. This set-up allows the modulation of the VOC flow rate, water content and column temperature. Finally, the regeneration of the absorbent was carried out by several absorption/desorption cycles without loss of absorption capacity. In conclusion, the overall results showed that DES have characteristics that allow them to be considered as promising solvents for VOC absorption.
17

Evaluation of the performance of photocatalytic systems for the treatment of indoor air in medical environments / Evaluation de la performance des systèmes photocatalytiques pour le traitement de l'air intérieur en milieu médical

Whyte, Henrietta Essie 07 December 2018 (has links)
La photocatalyse est une technologie d’oxydation avancée qui peut être utilisée pour améliorer la qualité de l'air dans les environnements intérieurs et pourrait être mise en œuvre dans les milieux médicaux. Dans les hôpitaux, les salles d'opération sont très exigeantes en matière de qualité de l'air intérieur et nécessitent des systèmes qui minimisent les concentrations des polluants générés par les différentes activités. Dans ce travail, le devenir de deux polluants spécifiques des blocs opératoires, l’acrylonitrile (produit chimique trouvé dans la fumée chirurgicale) et l'isoflurane (gaz anesthésique) lorsqu'ils passent dans un dispositif de traitement d’air photocatalytique est étudié. Tout d'abord, une évaluation paramétrique de la dégradation de l'isoflurane et de l'acrylonitrile en étudiant l'influence de la vitesse de l'air, de l'intensité lumineuse, de la géométrie du média photocatalytique, de la concentration initiale en polluants, de la présence de co-polluants chimiques, de la présence de particules et l’humidité relative sur leur efficacité de dégradation est réalisée. En second lieu, l’innocuité de l’utilisation de ce procédé pour la dégradation de l’isoflurane et de l’acrylonitrile par l’identification des éventuels intermédiaires formés au cours de leur dégradation est étudiée. Les expériences sont menées dans un réacteur dynamique en boucle fermée conçu pour étudier les polluants à faibles concentrations. Enfin, pour mieux comprendre comment le changement de géométrie du média photocatalytique influence l'efficacité de la dégradation, des simulations avec ANSYS14.5 sont effectuées et discutées au regard des résultats expérimentaux. / Photocatalytic oxidation (PCO) is an advanced air cleaning technology that is used asa means to improve air quality in indoor environments and could potentially be used inthe operating rooms (OR). In hospitals, operating rooms (ORs) are very demanding interms of the indoor air quality (IAQ) and require systems that minimize the concentrations of pollutants. In this work, the fate of two OR pollutants acrylonitrile (chemical found insurgical smoke) and isoflurane (anesthetic gas) when they go through a PCO device was investigated. Firstly, a parametric evaluation on the degradation of isoflurane and acrylonitrile by studying the influence of air velocity, light intensity, the change in media geometry, initial pollutant concentration, presence of chemical co-pollutants, presence of particles (bioaerosols) and relative humidity on their degradation efficiencies is performed. Secondly the safety of the use of PCO for the degradation of isoflurane and acrylonitrile through the identification of possible intermediates formed during their degradation is evaluated. The experiments were conducted in a closed loop reactor which has been designed to study low concentration air pollutants and has also been recently modeled. Finally, to better understand how the change in media geometry influenced the degradation efficiency, simulations with ANSYS 14.5 were performed and discussed.
18

Optimalizace distribuce vzduchu bazénových hal / Optimization of air distribution in swimming pool halls

Blasinski, Petr January 2014 (has links)
The work deals with solution of air distribution in swimming pool halls with regard to the dominant influences, which are creating a microclimate in these areas. Results of this work are graphs with evaporation of water and chemicals dependents on changing boundary con-ditions. There is followed with optimal design of air distribution, which is reflecting the critical specific effects of swimming pool halls.
19

Dépollution de l'air intérieur par catalyse économe en énergie sur catalyseurs en film mince chauffés par leur support métallique / Cleaning indoor air using low energy consumption thin film catalysts heated by their metal support

Leclercq, Jérôme 19 December 2013 (has links)
Ce travail montre la mise en œuvre d'une technique originale pour le chauffage rapide et bien contrôlé de catalyseurs sous forme de films minces déposés sur un structurant métallique. L'utilisation d'un système à induction électromagnétique adapté à un réacteur catalytique de type annulaire nous a permis d'étudier un certain nombre de matériaux catalytiques, déposés sur acier inoxydable, dans une perspective d'oxydation totale en CO2 et H2O de composés organiques volatiles (COV) présents dans l'air. La combustion de l'isopropanol et du toluène par l'oxygène de l'air a été étudiée en utilisant différents catalyseurs déposés sous forme de films minces: 1%Pt/Al2O3, 0,3%Pt/SnO2, 1%Pt/SnO2 et 1%Pt/YSZ. Les solides ont été préparés par imprégnation des oxydes correspondants par H2PtCl6 puis ont été déposés sur le support d'acier inoxydable par électrophorèse. Les principaux paramètres relatifs au mode de chauffage ont été étudiés de même que l'influence sur la conversion des COV de différents facteurs tels que la quantité de catalyseur, le pourcentage de platine ou la nature du support oxyde employé. Les informations fournies par ce système innovant ont également été comparées pour validation à celles obtenues à l'aide d'un système classique (microréacteur en quartz à lit traversé chauffé de manière conventionnelle) pour une réaction de référence qui est l'oxydation de CO en CO2. Le système décrit dans cette étude présente d'une part un intérêt pratique pour le traitement rapide de contaminations accidentelles de l'air ambiant, mais est aussi un très bon moyen d'obtenir des paramètres cinétiques fiables dans le domaine des catalyseurs en films minces utilisés dans de nombreux réacteurs structurés / This study shows the development of an innovative technique for a fast and well-controlled heating of catalysts deposited as thin films on a metallic support. The use of an electromagnetic induction system fitted to an annular catalytic reactor enabled us to study some catalytic materials deposited on stainless steel. The target application was the abatement of volatile organic compounds (VOCs) in the air. Isopropyl alcohol and toluene combustion by the oxygen was studied on various thin films catalysts, i.e. : 1%Pt/Al2O3, 0,3%Pt/SnO2, 1%Pt/SnO2 et 1%Pt/YSZ. Solids were prepared by wet impregnation of the corresponding oxides by H2PtCl6 and were deposited on the stainless steel support using an electrophoretic deposition technique. The main parameters of the heating system were investigated as well as the influence on VOCs abatement of various parameters such as the thickness of catalyst film, the platinum amount and the nature of the oxide. For validation purpose, the data provided by this innovative system were also compared to the ones provided by a classical one (quartz plug-through microreactor heated in a conventional way) in a reference reaction which was CO oxidation into CO2. The system described in this study shows on the one hand a real practical interest for fast remediation of indoor air polluted by VOCs, and on the other hand is a very powerful tool for obtaining kinetic data about thin layer catalysts used in many structured reactors
20

Pollution de l’air intérieur : mesure, impact sur la santé et traitement par méthodes photochimiques. / Indoor air pollution : measurement, health impact and photochemical methods treatment.

Le Bechec, Mickael 20 October 2016 (has links)
L’accroissement de la population humaine, l’agriculture intensive et le développement industriel créent une pollution de l’air qui aujourd’hui devient préoccupante pour notre santé et notre environnement. Si la qualité de l’air extérieur fait l’objet depuis plusieurs décennies de règlementations qui permettent aujourd’hui de constater une diminution globale de la pollution dans les grandes agglomérations européennes, la pollution de l’air intérieur a quant à elle été longtemps sous-estimée. En effet, avec le développement de matériaux composites pour la construction et l’ameublement, la gamme de polluants de l’air intérieur s’est très largement agrandie et les concentrations ont globalement augmenté. Plusieurs études ont ainsi montré que de nombreux composés organiques volatils étaient détectés dans l’air intérieur à des concentrations bien plus élevées qu’à l’extérieur. D’autre part, la modification des modes de vie sédentaires et citadines ont pour conséquence une augmentation du temps passé dans des espaces confinés comme les logements, les lieux de travail et les transports en commun. Le simple renouvellement de l’air intérieur par de l’air extérieur devenant de moins en moins satisfaisant dans les grandes agglomérations, de nouvelles méthodes de traitement sont actuellement développées pour diminuer les concentrations de ces polluants tout en limitant la consommation d’énergie. La photocatalyse, en tant que procédé d’oxydation avancé fait partie des technologies intéressantes pour minéraliser des composés organiques volatils (COV). Après un rapide rappel du contexte sociétal de la pollution atmosphérique, les conditions de mesures et les méthodes possibles pour le traitement de cette pollution sont présentées. Le chapitre suivant regroupe les résultats sur le développement de matériaux photocatalytiques innovants et la mesure de leur efficacité. La première partie de ce chapitre fait le bilan des réacteurs photocatalytiques adaptés à l’étude de réactions à l’interface solide-gaz et résume les nombreuses difficultés liées à l’évaluation des performances de divers matériaux dans des conditions le plus souvent difficilement comparables. Dans la seconde partie, un premier matériau composite constitué de film polymère et de dioxyde de titane a été caractérisé par sa capacité à oxyder un composé volatil, le diméthyle disulfure, utilisé en agriculture pour la fumigation. Le développement d’un second matériau photocatalytique original, constitué de fibres de TiO2 pur a, quant à lui, été caractérisé par sa capacité à minéraliser des COV représentatifs de la pollution de l’air intérieur (acétone, heptane, toluène). Les deux dernières parties de ce chapitre se situent à l’interface entre la photochimie et la biologie. Dans un premier temps, la capacité d’inactivation bactérienne d’un textile « intelligent » sur lequel sont fixées des particules de dioxyde de titane couplées à un photosensibilisateur a été étudiée et l’efficacité sous rayonnement visible de ce tissu original a été analysée. L’impact de la pollution de l’air intérieur sur des cellules de la peau fait l’objet de la dernière partie de ce chapitre. Pour cela un montage permettant d’exposer des cellules de kératinocytes en culture, mais également des biopsies de peau humaine, à des concentrations contrôlées en COV a été mis au point. Nous avons ainsi pu mettre en évidence une réponse cellulaire à ce stress environnemental et préciser l’origine de ce stress. Enfin ce travail se termine par une ouverture sur des projets de recherche actuellement en cours ayant pour objet la mesure des espèces réactives de l’oxygène impliquées dans les réactions photochimiques et le développement de nouveau matériaux hybrides polymère/photosensibilisateurs. Des idées de projets à l’interface de la photochimie et de la biologie ouvrent de nouvelles perspectives à la suite de ces premiers résultats. / The increase of human population, the modern agriculture and industrial development generate air pollution, which is nowadays worrying for health and environment. Since several decades, outdoor air pollution has been regulated giving rise a global decrease of pollution in the most important European cities. However indoor air pollution was neglected for a long time. Indeed with development of composite materials for building and furnishing, the number of air pollutants strongly increased together with their concentrations. Several studies have thus demonstrated that numerous volatile organic compounds (VOC) were detected indoor at much higher concentration than outdoor. Moreover, due to the modification of sedentary and urban lifestyles, the time spent in confined spaces like housing, working places and public transportation increases. It is less and less satisfactory to simply renew indoor air with outdoor air in most of urban agglomerations. Accordingly, new processes for air treatment are developed in order to decrease indoor air pollutant concentrations while limiting energetic consumption. Photocatalysis is an advanced oxidation process potentially interesting for VOC removal. After a short reminder on the societal context of atmospheric pollution, measurement and treatment methods are presented in chapters I and II. The following chapter gathers the results obtained on the development of new photocatalytic materials and on the measure of their efficiency. The first part of this chapter is devoted to an overview of photocatalytic reactors for gas solid reactions and summarizes the numerous problems arising from the comparison of different materials under various conditions, which are not always similar. In the second part, a composite material made of titanium dioxide encapsulated in a polymer film is characterized and used for the oxidation of a volatile compound used for agricultural fumigation, dimethyl disulfide. The spectroscopic analysis led to the optimization of the material as a function of its thickness and its titanium dioxide loading. A second innovative photocatalytic material made of pure TiO2 fibers is characterized by its mineralization ability of representative indoor air VOC (acetone, heptane, and toluene). The performance of this material is compared to that of a commercial one, Quartzel ® made of TiO2 deposited on quartz fibers, under strictly identical conditions. The two last parts of this chapter are at the interface between photochemistry and biology. In a first strep, bacterial inactivation by a smart textile where titanium dioxide particles coupled with a photosensitizer is studded under visible light. In the last part, the impact of indoor air pollution on skin cells is presented. A dedicated device allowing keratinocytes culture cells and skin biopsies exposures to controlled VOC concentrations is developed. It is thus possible to evidence and to determine the origin of the cellular response to this environmental stress. At last, new research projects for a near future are then presented. They concern the determination of reactive oxygen species involved in photochemical reactions and the development of new hybrid polymers encapsulating photosensitizing molecules. Prospective ideas at the interface of photochemistry and biology conclude this memory.