The use of dioxy MP 14 (stabilized aqueous chlorine dioxide) to control environmental airborne microorganismsMbamalu, Oluchi Nneka January 2009 (has links)
Magister Pharmaceuticae - MPharm / Dioxy MP 14 is a locally developed form of stabilized chlorine dioxide in an aqueous medium. It has all the sanitizing properties of chlorine dioxide gas, a neutral compound of chlorine in the +IV oxidation state, which has been used extensively as a non-toxic sterilizing agent with various applications. In this study, Dioxy MP14 was tested in a commercial chicken pen to determine its effectiveness as an environmental sanitizing agent. Control of environmental microbes in a chicken pen is important to ensure healthy birds and optimum egg production. The biocide was introduced via an overhead misting system with a variable dosing pump at various daily frequencies.The effectiveness of environmental microorganism control was determined with air settle plates. The health and performance of the chickens were evaluated and compared to chickens in a control pen.The results show a decrease in airborne microbial load in the treated pen. Better egg production and lower mortality of the chickens in the treated pen compared to the control pen, indicate effective environmental microbial control was achieved with a residual 7.46 ppm Dioxy MP 14 at a daily dose given for 5 minutes every 2 hours.This study was a pilot study, with encouraging results, for an extended study to investigate the feasibility of introducing Dioxy MP 14 through a misting system in a clinical environment (clinics and hospitals) to control airborne pathogens like Mycobacterium tuberculosis thereby reducing the infection risks for clinical workers and medical staff.
|
2 |
Reduzierung der Keim- und Staubbelastung der Stallluft in der Schweinehaltung mit UVC-kombinierter UmluftfiltrationEisenlöffel, Lisa 07 June 2022 (has links)
Einige Krankheitserreger, die für hohe wirtschaftliche Verluste in der Schweineindustrie sorgen, können über mehrere Kilometer über die Luft übertragen werden. Staub und daran gebundene Mikroorganismen können sowohl bei Tieren, als auch bei Menschen, die in der Landwirtschaft arbeiten, zu gesundheitlichen Beeinträchtigungen führen. Um den aerogenen Erregereintrag und die Belastung der Gesundheit durch Stallstaub zu reduzieren, können Filtertechniken, wie Umluftfiltration, zum Einsatz kommen. In mehreren Studien konnte beim Einsatz von Umluftfiltration im Schweinestall ein positiver Einfluss auf die Lungengesundheit der Tiere verzeichnet werden. Auf diesen Erkenntnissen aufbauend, war es Gegenstand dieser Arbeit die positiven Effekte der Umluftfiltration mit der keimtötenden Wirkung von UVC-Strahlen zu kombinieren und somit den Keimgehalt der Stallluft zu reduzieren. Das Ziel der vorliegenden Arbeit war es, die Effizienz von UVC-kombinierter Umluftfiltration hinsichtlich der Reduktionsrate luftgetragener Mikroorganismen im Labormaßstab zu untersuchen. Im zweiten Teil der Studie wurde ein UVC-Umluftfiltermodul in einen kleinen Stall integriert, um dessen Einfluss auf die Qualität der Stallluft bzw. auf die Staub- und Bakterienmenge im Vergleich zu einem Referenzstall zu überprüfen. Für Testdurchläufe im Labormaßstab wurden Aerosole mit Staphylococcus aureus, Ac-tinobacillus pleuropneumoniae, dem Virus des seuchenhaften Spätaborts (PRRSV) und dem Porcinen Parvovirus (PPV) erzeugt. In einem Luftfilterprüfstand wurden mit jedem Erreger je fünf unabhängige Testläufe mit und ohne UVC-Bestrahlung durchgeführt. Bei einigen Test-durchläufen wurde die relative Luftfeuchtigkeit (rLF) verändert, um den Einfluss einer erhöh-ten rLF auf die UVC-Wirksamkeit zu bewerten. Die Reduktionsrate entsprach der Differenz der infektiösen Partikel gemessen vor dem Luftfilter und hinter dem Luftfilter. Um das Überleben von Krankheitserregern im Filtermaterial zu untersuchen, wurden die Filter in ge-trennten Plastiktüten aufbewahrt. Nach bestimmten Zeitintervallen wurden Filterproben ent-nommen, gepoolt und inkubiert. Es folgte eine Virustitration bzw. eine Zählung der Bakterien.
Die Feldstudie fand in einem kleinen Instituts-eigenen Stall statt, der aus zwei getrennten Stallabteilen bestand. Es wurden wöchentlich Luftmessungen über einen Zeitraum von 13 Wochen bzw. 16 Wochen in jedem Stallabteil durchgeführt. Die Staub- und Bakterienmenge der Stallluft wurde an drei verschiedenen Probennahmestellen gemessen. Zusätzlich wurden Luft-Proben direkt vor und hinter dem UVC-Modul entnommen. Weiterhin wurde die Ammoniak- und CO2-Konzentration, sowie Temperatur und rLF aufgezeichnet. Die Reduktionsraten der Staub- und Bakterienmenge der Stallluft wurde durch Berechnung der Werteverhältnisse (Ratios) der Messwerte aus Stall 1 (UVC-Modul) verglichen zu Stall 2 (Referenzstall) bestimmt. Ratios kleiner als eins entsprachen einer relativen Verringerung der Bakterienzahl bzw. Staubmenge. Durch logarithmische Transformierung der Ratios wurden annähernd normalverteilte Werte gewährleistet. Unter Verwendung eines t-Tests mit einer Probe auf einem Signifikanzniveau von 5 % wurden Nullhypothesen von unveränderten mittleren Bakterien- bzw. Staubwerten geprüft. Zusätzlich wurden 95 %ige Konfidenzintervalle für die geschätzten Stichprobenmittelwerte berechnet.
Bei Tests im Labormaßstab führte das UVC-kombinierte Filtersystem zu einer Reduzierung der viralen und bakteriellen Partikel um mehr als 99 %. Die rLF hatte keinen Einfluss auf die UVC-Effizienz. Die Lebensfähigkeit der Pathogene im Filtermaterial variierte in Abhängigkeit vom verwendeten Pathogen und der rLF, wobei sich S. aureus und PPV am resistentesten darstellten. In der Feldstudie erreichten wir in der Stallluft von Stall 1 (mit dem UVC-Modul) eine signifikant niedrigere Bakterienmenge im Vergleich zum Referenzstall (Stall 2). Die Bakterienkonzentration der Stallluft konnte durchschnittlich auf 37 % reduziert werden, während die Staubmenge in viel geringerem Maße (auf 78 %) verringert werden konnte. Messungen unmittelbar vor und hinter dem UVC-Modul ergaben in der Stallluft eine Reduktion von 99,4 % für Bakterien und von 95,0 % für Staub. Wir konnten die Wirksamkeit von UVC-Strahlung zur Luftdesinfektion im Labormaßstab mit einer Reduktionseffizienz von >99 % für ausgewählte Viren und Bakterien erfolgreich demonstrieren. Darüber hinaus erwies sich die Kombination von UVC-Strahlung und Umluftfiltration als erfolgreich bei der Reduzierung der Bakterien- und Staubmenge der Stallluft in einem kleinen Schweinbestand. Der Einsatz dieser Technologie könnte die allgemeine Stallluftqualität in Nutztierställen verbessern.:1 Einleitung
2 Literaturübersicht
2.1 Ausgewählte Pathogene in der Schweinehaltung
2.1.1 Viren
2.1.1.1 Porcine reproductive and respiratory syndrome virus (PRRSV)
2.1.1.2 Ungulate protoparvovirus 1 (Porcines Parvovirus, PPV)
2.1.2 Bakterien
2.1.2.1 Actinobacillus pleuropneumoniae (APP)
2.1.2.2 Methicillin-resistente Staphylococcus aureus (MRSA)
2.2 UVC-Strahlung
2.2.1 Allgemeines
2.2.2 Luftdesinfektion mit UVC-Strahlung
2.3 Luftfiltration
2.3.1 Grundlagen der Filtration
2.3.2 Filterklassen
2.3.3 Luftfiltration in der Tierhaltung
2.4 Stallklima
2.4.1 Zusammensetzung der Stallluft
2.4.1.1 Organische Komponenten
2.4.1.1.1 Staub
2.4.1.1.2 Mikrobielle Zusammensetzung der Stallluft
2.4.1.2 Chemische und physikalische Komponenten
2.4.1.2.1 Temperatur, relative Luftfeuchtigkeit (rLF), Luftgeschwindigkeit
2.4.1.2.2 Ammoniak (NH3)
2.4.1.2.3 Kohlendioxid (CO2)
3 Veröffentlichung
3.1 Eigenanteil
3.2 Fremdanteil
4 Diskussion
5 Zusammenfassung
6 Summary
Literaturverzeichnis
Danksagung / Some pathogens, which cause high economic losses in the swine industry, can be transmitted over several kilometres via the airborne route. Dust and microorganisms bound to dust can lead to serious health problems for animals, as well as for human beings working in the agricultural environment. In order to reduce airborne pathogen burden and to lower the negative health impact of stable dust, air filtration technologies such as recirculating air filtration can be used. In several studies, a positive impact on swine lung health was seen, when recirculating air filtration was implemented in the pig barn. Filtration of supply air can minimize the risk of introducing airborne pathogens to indoor air. Based on this knowledge, the aim of this study was to combine the positive effects of recirculating air filtration with the germicidal effect of UVC-irradiation, and thus to reduce germ content of stable air. The aim of the current study was, to assess the efficiency of UVC irradiation combined to air filtration in reducing airborne microorganisms at laboratory scale. In a second part, a UVC-combined recirculating air filtration module (UVC module) was implemented in a small animal facility in order to assess its improvement of air quality with regard to airborne bacteria and dust. Tests at laboratory scale were performed using aerosols of Staphylococcus aureus, Actinobacillus pleuropneumoniae, porcine reproductive and respiratory syndrome virus (PRRSV) and porcine parvovirus (PPV). Five independent test runs were performed in a test chamber with each pathogen, with and without UVC irradiation, respectively. Relative humidity (RH) was manipulated in some test runs to evaluate the influence of increased RH to UVC-efficacy. Reduction efficiencies were calculated by numbers of pathogens entering and leaving the test chamber. To investigate the survival of pathogens in the filter material, the filters were stored in separated plastic bags. Filter samples were taken after certain time intervals, pooled and incubated, followed by virus titration or counting of bacteria. Our field study occurred in a small pig facility consisting of two separated barns. Weekly air measurements were conducted over a period of 13 weeks (10 piglets) and 16 weeks (11 piglets) in each barn, respectively. Airborne dust and bacteria amount was sampled and calculated at three different sampling points. Furthermore, samples were taken right in front and behind the UVC-module. In addition, ammonia, CO2, temperature and RH were recorded. Relative reduction of airborne dust and bacteria amount was determined by calculating ratios of values in barn 1 (UVC-module) compared to barn 2 (reference). Ratios smaller than one correspond to a relative reduction of bacterial counts/dust amount. Ratios were log-transformed to guarantee approximately normally distributed values. Null hypotheses of unchanged mean bacterial or dust counts (i.e., mean ratios equal one) were tested using one sample t-tests on a significance level of 5 %. In addition, 95 % confidence intervals (CI) were calculated for the estimated sample means. UVC-combined air filtration in tests at laboratory scale resulted in a more than 99 % reduction of viral and bacterial particles. RH had no influence on UVC efficiency. Viability in the filter matter varied depending on the pathogen used and RH with S. aureus and PPV being most resistant. In the field study, airborne bacterial numbers were significantly lower in the barn equipped with the UVC module compared to the reference barn. On average, a reduction to 37 % of reference values could be achieved for bacteria, whereas the amount of total dust was reduced to a much lesser extent (i.e. to 78 % of reference values). Measures taken in front of and behind the UVC module revealed a reduction of 99.4 % for airborne bacteria and 95.0 % for total dust. We successfully demonstrated the effectiveness of air disinfection using UVC irradiation at laboratory scale with reduction efficiencies of >99 % for certain viruses and bacteria. Moreo-ver, combining UVC irradiation to recirculating air filtration proved to be successful in reduc-ing airborne bacteria and dust in a small animal facility. The implementation of such devices might improve the overall environmental quality in animal facilities.:1 Einleitung
2 Literaturübersicht
2.1 Ausgewählte Pathogene in der Schweinehaltung
2.1.1 Viren
2.1.1.1 Porcine reproductive and respiratory syndrome virus (PRRSV)
2.1.1.2 Ungulate protoparvovirus 1 (Porcines Parvovirus, PPV)
2.1.2 Bakterien
2.1.2.1 Actinobacillus pleuropneumoniae (APP)
2.1.2.2 Methicillin-resistente Staphylococcus aureus (MRSA)
2.2 UVC-Strahlung
2.2.1 Allgemeines
2.2.2 Luftdesinfektion mit UVC-Strahlung
2.3 Luftfiltration
2.3.1 Grundlagen der Filtration
2.3.2 Filterklassen
2.3.3 Luftfiltration in der Tierhaltung
2.4 Stallklima
2.4.1 Zusammensetzung der Stallluft
2.4.1.1 Organische Komponenten
2.4.1.1.1 Staub
2.4.1.1.2 Mikrobielle Zusammensetzung der Stallluft
2.4.1.2 Chemische und physikalische Komponenten
2.4.1.2.1 Temperatur, relative Luftfeuchtigkeit (rLF), Luftgeschwindigkeit
2.4.1.2.2 Ammoniak (NH3)
2.4.1.2.3 Kohlendioxid (CO2)
3 Veröffentlichung
3.1 Eigenanteil
3.2 Fremdanteil
4 Diskussion
5 Zusammenfassung
6 Summary
Literaturverzeichnis
Danksagung
|
Page generated in 0.0784 seconds