• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

CARACTERIZAÇÃO Tecnológica de Blocos Cerâmicos de Alvenaria de Vedação Produzidos Por empresas Cerâmicas do Estado do Espírito Santo

POSSES, I. P. 06 November 2013 (has links)
Made available in DSpace on 2016-08-29T15:10:13Z (GMT). No. of bitstreams: 1 tese_7217_IVANA PEREIRA DAS POSSES.pdf: 3175796 bytes, checksum: 988a36e989c28c8a3313a12661011ba9 (MD5) Previous issue date: 2013-11-06 / Este trabalho tem por objetivo a caracterização tecnológica de blocos cerâmicos destinados à alvenaria de vedação, produzidos em 17 indústrias cerâmicas do estado do Espírito Santo, das quais foram avaliados blocos vazados com dimensões nominais de 90 mm X190 mm X190 mm. A contribuição deste projeto é revelar ao consumidor capixaba a qualidade dos blocos de alvenaria de vedação produzidos no Estado, e apresentar sugestões de modificações nos processos para aprimoramento dos padrões de qualidade. A caracterização das indústrias foi realizada através de visitas, aplicação de questionários, amostragem e análise das características geométricas, físicas e mecânicas dos blocos cerâmicos de acordo com a norma ABNT NBR 15.270-1 (ABNT, 2005). Os resultados indicaram que nenhuma das indústrias cerâmicas analisadas obteve seus lotes aceitos, o que nos leva a concluir pela necessidade das indústrias cerâmicas em avaliar os processos industriais e materiais utilizados. Concluimos que as correções principais se resumem em realização do sazonamento de no mínimo um ano para a matéria prima, correção das dimensões da boquilha, controle da dosagem, umidade e uniformidade da massa cerâmica, controle da intensidade e velocidade da secagem, controle da uniformidade e temperatura de queima de no mínimo 900°C.
2

Ações de controle de operações da produção de alvenaria de vedação em blocos cerâmicos : um estudo de caso em Brasília/DF / Stock control of sealing masonry block ceramic production: a case study in Brasilia/DF

Vasconcelos, Walter Segond de 15 January 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2015. / Submitted by Cristiane Mendes (mcristianem@gmail.com) on 2015-07-07T12:37:56Z No. of bitstreams: 1 2015_WalterSegondDeVasconcelos.pdf: 3697697 bytes, checksum: a2a1a8adcc4a171864388a21cce1a782 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2015-07-29T15:29:10Z (GMT) No. of bitstreams: 1 2015_WalterSegondDeVasconcelos.pdf: 3697697 bytes, checksum: a2a1a8adcc4a171864388a21cce1a782 (MD5) / Made available in DSpace on 2015-07-29T15:29:11Z (GMT). No. of bitstreams: 1 2015_WalterSegondDeVasconcelos.pdf: 3697697 bytes, checksum: a2a1a8adcc4a171864388a21cce1a782 (MD5) / Esta pesquisa aborda o processo de execução de alvenaria de vedação em blocos cerâmicos e as ações de controle sobre o mesmo. É fato que as empresas construtoras procuram me-lhorar a sua eficiência técnica e econômica e a sua eficácia por meio de sistemas de gestão da qualidade, fundamentados em requisitos do SiAC, Nível “A”. A eficácia, porém, deste sistema nem sempre é alcançada no que se refere aos objetivos organizacionais. A pesquisa demonstrou que as ações de controle exercidas pelas empresas investigadas sobre o proces-so de execução de alvenarias de vedação, não são suficientes para garantia da conformida-de da alvenaria de vedação. Chegou-se a essa conclusão a partir da comparação e avaliação das ações de controle das empresas investigadas na execução de alvenarias de vedação com as de referência, definidas a partir do Código de Práticas n. 01 da FINEP, publicado em 2009. Os resultados demonstraram que somente 39,54% das ações de controle de refe-rência encontram-se documentadas nos sistemas de gestão da qualidade das empresas in-vestigadas. Quanto ao que de fato é feito pelas empresas em suas obras, 62,10% das ações de controle de referência são aplicadas na execução das alvenarias de vedação. Tais resul-tados comprovam que muitas das ações de controle implantadas pelas empresas não se encontram documentadas, o que compromete a eficácia dos treinamentos em obra, a repe-tibilidade dos serviços e a conformidade do produto. / This research addresses the process of sealing masonry running on ceramic blocks and control actions on it. Is fact that constructions enterprises seek to improve their technical and economic efficiency and its effectiveness through quality management systems, based on SiAC requirements, Level “A”. The afficacy, however, of this system, is not always achieved in relation to the organizational objectives for the production quality of works. The research has shown that the control actions carried out by the investigated enterprises on the implementation process of sealing masonry are not sufficient for ensuring conformi-ty on it. It reached this conclusion from the comparison and evaluation of the control ac-tions of the investigated enterprises in the execution of sealing masonry with the reference set from the FINEP- Code of Practice # 1, published in 2009. The results demonstrated that only 39.54% of the reference control actions are documenteds in the quality management systems of the enterprises investigated. As to what in fact is done by enterprises in their works, 62.10% of the reference control measures are applied in the implementation of seal-ing masonry. Such results show that construction enterprises do not ensure compliance of the sealing masonry ceramic blocks the requirements applicable to them and that many of the control measures implemented by enterprises are not documented, which undermines the effectiveness of training in work, repeatability of services and product conformity.
3

Comportamento estrutural de edifícios de múltiplos andares considerando as alvenarias de vedação

Dias, Erlon Mota Barbosa 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T17:37:50Z (GMT). No. of bitstreams: 2 arquivo2412_1.pdf: 3567329 bytes, checksum: 01065a71280432db7cc14fde9a96d192 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Este trabalho tem por objetivo analisar os efeitos causados pelas alvenarias de vedação no comportamento de edifícios de múltiplos pisos. A análise tridimensional foi efetuada através de um edifício com 26 pavimentos tipo e 01 de cobertura, onde foi verificada a estrutura em concreto armado, e a estrutura em concreto armado com a presença dos painéis de alvenarias de vedação. Os painéis de alvenaria foram representados através de elementos de barra com suas larguras equivalentes, as quais foram calculadas baseadas no FEMA (Federal Emegency Management Agency) 356. Os elementos estruturais pilares e vigas foram modelados através de elementos de barras, e as lajes consideradas como diafragma rígido. As estruturas de concreto armado foram analisadas de acordo a NBR-6118/2003. Como conclusão, verificou-se que os painéis de alvenaria apresentam grande contribuição para o enrijecimento da estrutura, reduzindo-se consideravelmente os deslocamentos horizontais. Já nos casos de cargas nas fundações, e dos esforços nos pilares e nas vigas, nota-se que em alguns casos a estrutura com a presença dos painéis apresenta-se de maneira favorável, e em outros, apresenta-se de forma desfavorável, para o dimensionamento dos elementos estruturais
4

Estudo das ligações entre pilares de concreto e alvenaria cerâmica de vedação

Jodas, Marcela [UNESP] 19 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-19Bitstream added on 2014-06-13T20:13:41Z : No. of bitstreams: 1 jodas_m_me_ilha.pdf: 1356266 bytes, checksum: 018e99760788ea15eba777612fafa224 (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / As estruturas de concreto armado vêm se tornando cada vez mais esbeltas, aliadas ao menor tempo de execução das edificações e aos menores prazos de execução da fixação da alvenaria na estrutura, cada vez com mais freqüência observa-se a formação dos estados patológicos nas alvenarias. As estruturas de concreto armado apresentam progressivamente deformações mais acentuadas, fazendo com que as paredes de vedação trabalhem, oferecendo resistência a esses deslocamentos surgindo assim patologias que se apresentam na forma de fissuras na interface pilar/alvenaria. Desse modo, surge a necessidade de estudos das ligações empregadas na interface pilar/alvenaria, que têm por objetivo “solidarizar” estrutura e alvenaria, distribuindo as deformações excessivas da estrutura que se traduzem na forma de fissuras e com isso diminuir a ocorrência de patologias nas alvenarias de vedação. Para tal, foram desenvolvidos ensaios de diferentes formas de ligação da interface pilar/alvenaria de modo a avaliar a eficiência dos dispositivos empregados no mercado da construção de edifícios de São Paulo atualmente, como a tela metálica eletrosoldada. Numa primeira etapa foram realizados ensaios de arrancamento direto à tração, de modo a se estudar o comportamento do dispositivo quando submetido ao esforço de tração. Foram ensaiados também prismas de alvenaria, com diferentes dispositivos de ligação inseridos de modo a se avaliar as resistências à tração das ancoragens inseridas na junta de argamassa, e numa terceira etapa, foram realizados ensaios em pequenas paredes, para se determinar o desempenho das ancoragens na ligação de paredes e pilares de concreto armado, na situação real. / Structures of reinforced concrete are becoming more slender, associated to the short time of building construction and with the lesser periods of masonry fixation in the structure, each time with more frequency can be observed the formation of pathological state in masonry. The structures of reinforced concrete progressively presents more accentuated deformation, making masonry to work, offering strength to these displacements, creating pathology that appears like cracks in the interface of column/masonry. Thus, it is necessary to study the bonds used in the interface column/masonry, wich has as objective “join” the structure and the masonry, spreading the excessive deformations of the structure that comes up as cracks, and diminishing the occurrence of damages in the forbid masonry. In order to do this, different tests in the interface column/masonry were developed in order to evaluate the efficiency of device used in the civil construction in São Paulo, as tela metálica eletrosoldada. In the first step, pull-out tests were done to sutdy the behavior of the device when submitted to a tensile strength. Prisms were also tested, with different kinds of bond gadgets inserted in order to evaluate the resistance in a traction of devices in the anchorages inserted in the grouts, and in a third step, small walls were tested to analyze the behavior of anchorages in the bond of wall and column, in the real situation.

Page generated in 0.0739 seconds