• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 1
  • Tagged with
  • 12
  • 12
  • 8
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

CARACTERIZA??O DA COBERTURA DE SINAIS NA FAIXA DE 700 MHZ EM AMBIENTES INTERNOS CONSIDERANDO OS EFEITOS DA POLARIZA??O E DO AZIMUTE DA ANTENA DIRETIVA

Fraz?o, Maria do Carmo de Luna Malheiros 07 1900 (has links)
Submitted by Alex Sandro R?go (alex@ifpb.edu.br) on 2016-11-23T14:05:28Z No. of bitstreams: 1 CARACTERIZA??O DA COBERTURA DE SINAIS NA FAIXA DE 700 MHZ EM AMBIENTES INTERNOS CONSIDERANDO OS EFEITOS DA POLARIZA??O E DO AZIMUTE DA ANTENA DIRETIVA.pdf: 3166825 bytes, checksum: 661cc825c83146a571ccfe6ff55de464 (MD5) / Approved for entry into archive by Alex Sandro R?go (alex@ifpb.edu.br) on 2016-11-23T14:06:22Z (GMT) No. of bitstreams: 1 CARACTERIZA??O DA COBERTURA DE SINAIS NA FAIXA DE 700 MHZ EM AMBIENTES INTERNOS CONSIDERANDO OS EFEITOS DA POLARIZA??O E DO AZIMUTE DA ANTENA DIRETIVA.pdf: 3166825 bytes, checksum: 661cc825c83146a571ccfe6ff55de464 (MD5) / Made available in DSpace on 2016-11-23T14:06:22Z (GMT). No. of bitstreams: 1 CARACTERIZA??O DA COBERTURA DE SINAIS NA FAIXA DE 700 MHZ EM AMBIENTES INTERNOS CONSIDERANDO OS EFEITOS DA POLARIZA??O E DO AZIMUTE DA ANTENA DIRETIVA.pdf: 3166825 bytes, checksum: 661cc825c83146a571ccfe6ff55de464 (MD5) Previous issue date: 2015-07 / Com o aparecimento dos sistemas de comunica??o pessoal, tornou-se importante a caracteriza??o da propaga??o em ambientes fechados. A atenua??o no espa?o livre, a propaga??o por multipercurso e as intera??es que a onda mant?m com obst?culos s?o fen?menos mais relevantes associados ? propaga??o em ambientes interiores. Entretanto, se o canal indoor for bem caracterizado os efeitos das perdas de propaga??o eletromagn?ticas podem ser minimizadas, atrav?s da varia??o angular da antena do transmissor, a fim de encontrar a posi??o adequada para a localiza??o do transmissor. No contexto de uma rede sem fio, um ambiente interno difere de um ambiente externo em dois aspectos: menor raio de cobertura e maior variabilidade no ambiente. Constata-se, na pr?tica, que a propaga??o dentro de edifica??es ? influenciada por aspectos espec?ficos, tais como sua arquitetura e pelos materiais usados na constru??o. Nas ?ltimas d?cadas foram desenvolvidos e aperfei?oados v?rios modelos de predi??o que consideram as caracter?sticas do ambiente interno. O presente trabalho tem por objetivo estabelecer a caracteriza??o da cobertura de sinais de comunica??o sem fio em ambientes interiores na faixa de frequ?ncia em torno de 700 MHz. Essa banda foi escolhida devido a sua destina??o para ser utilizada pelos sistemas de comunica??o em banda larga 4G/LTE no Brasil. Os resultados simulados foram obtidos utilizando o programa comercial WinProp?, com base no m?todo do Tra?ado de Raios. Durante as simula??es foi proposto um m?todo simplificado de predi??o de cobertura, onde foram considerados transmissores virtuais, posicionados pr?ximos ?s paredes de in?cio de cada corredor transversal (situa??o sem visada entre transmissor e receptor), que consideraram como pot?ncias de sa?das as mesmas pot?ncias aferidas naqueles pontos ou locais, a partir do transmissor real. As campanhas de medi??es para a caracteriza??o experimental da cobertura de sinal foram realizadas, obtendo-se valores m?dios do sinal em intervalos regularmente espa?ados, de modo a se garantir uma menor influ?ncia do fen?meno de desvanecimento r?pido e uma maior espacialidade entre elas. Deste modo, os resultados obtidos mostraram uma boa concord?ncia entre os valores simulados, medidos e te?ricos, calculados a partir da f?rmula de Friis, nas situa??es com visada e sem visada direta.
2

Avaliação da qualidade do ar em ambientes internos: biblioteca pública / Indoor air quality investigation: public library

Nascimento, Guilherme Caetano do 01 April 2011 (has links)
Ao longo de quinze meses, foram monitorados na Biblioteca Pública Amadeu Amaral, da cidade de São Carlos, SP, os níveis de temperatura, umidade relativa, ruído, intensidade luminosa, contaminação por dióxido de carbono, material particulado total (MPT) e suas frações respiráveis (MP1, MP2,5, MP7 e MP10), avaliação da taxa de ventilação e ocupação, concentração de bioaerossóis e sua identificação. Além disso, foi aplicado um questionário aos ocupantes do local com o intuito de levantar as principais reclamações e queixas relacionadas à qualidade do ar interior. Os resultados mostraram o desconforto térmico do local em todas as salas monitoradas, altos níveis de ruído proveniente do ambiente externo, inadequações relativas à iluminação do local e necessidade de uma atenção especial à taxa de ocupação do prédio. Durante alguns momentos das medições, os níveis de ruído ultrapassaram a barreira dos 80 dB(A), que é um valor bem acima do recomendado em normas, revelando-se um fator de risco para seus usuários e funcionários. Não foram encontrados problemas relacionados à contaminação biológica do local, analisando a concentração de bactérias e fungos. A taxa de ventilação possui valor adequado para o piso 1 e a concentração de gás carbônico se manteve de acordo com os padrões estabelecidos em normas. As respostas dos questionários confirmam os principais resultados encontrados para a Biblioteca, como os altos níveis de ruído, o desconforto térmico do local e as inadequações da iluminação. As recomendações são pautadas na necessidade de realização de ensaios gravimétricos da concentração de material particulado e o desenvolvimento de estudos específicos para a adoção de medidas mitigadores da poluição sonora e, também, da adequação das salas para o conforto térmico dos ocupantes. / Over fifteen months, levels of temperature, humidity, noise, light intensity, contamination by carbon dioxide, total suspended particles (TSP) and respirable fractions (PM1, PM2.5, PM7 and PM10) were monitored at the Public Library Amadeu Amaral at São Carlos, SP. Investigation of the ventilation rate and occupancy, concentration of bioaerosols and identification were also performed. In addition, a questionnaire was handed over to the occupants of the site in order to raise the main complaints related to indoor air quality. The results showed the discomfort of the place at all rooms monitored, high levels of noise from the outside environment, inadequacies relating to the site illumination and special attention to the building occupancy. During some measurements, the noise levels exceeded the barrier of 80 dB (A), which is above the recommended standards and proved to be a risk factor for its users and employees. No problems were found related to the site biological contamination, analyzing the concentration of bacteria and fungi. The ventilation rate has adequate value to the first floor and carbon dioxide concentration was maintained in accordance with the standards. The questionnaire responses confirm the main findings to the library, such as high noise levels, thermal discomfort and the illumination problem. The main recommendations are based on the need of gravimetric particulate matter investigation and development of specific studies for the adoption of mitigation measures on noise pollution and also the suitability of the rooms to the thermal comfort of occupants.
3

Uma plataforma adapt?vel para localiza??o em ambientes internos / An adaptable platform for indoor location

Melo Neto, M?rio Andrade Vieira de 22 February 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-07-08T20:47:19Z No. of bitstreams: 1 MarioAndradeVieiraDeMeloNeto_DISSERT.pdf: 5443325 bytes, checksum: 58107dcaa8860d62298373922e29468e (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-07-11T20:52:07Z (GMT) No. of bitstreams: 1 MarioAndradeVieiraDeMeloNeto_DISSERT.pdf: 5443325 bytes, checksum: 58107dcaa8860d62298373922e29468e (MD5) / Made available in DSpace on 2016-07-11T20:52:07Z (GMT). No. of bitstreams: 1 MarioAndradeVieiraDeMeloNeto_DISSERT.pdf: 5443325 bytes, checksum: 58107dcaa8860d62298373922e29468e (MD5) Previous issue date: 2016-02-22 / Os sistemas de localizac?a?o te?m se tornado cada vez mais parte integrante da vida das pessoas. Em ambientes externos, o GPS se apresenta como tecnologia padra?o, largamente difundida e utilizada. No entanto, as pessoas costumam passar a maior parte do seu tempo dia?rio dentro de ambientes internos, como: hospitais, universidades, fa?bricas, edi- fi?cios, entre outros. Nesses ambientes, o GPS tem seu funcionamento comprometido na?o obtendo um posicionamento preciso. Atualmente, para realizar a localizac?a?o de pessoas ou objetos em ambientes internos na?o existe nenhuma tecnologia que consiga atingir os mesmos resultados obtidos pelo GPS em ambientes externos. Devido a isso, e? necessa?rio considerar a utilizac?a?o de informac?o?es provenientes de diversas fontes fazendo uso de di- ferentes tecnologias. Dessa forma, esse trabalho tem como objetivo geral construir uma plataforma Adapta?vel para localizac?a?o ambientes internos. Baseado nesse objetivo, e? pro- posta a plataforma Indolor. Essa plataforma tem como objetivos permitir o recebimento de informac?o?es provenientes de diferentes fontes, ale?m de realizar o processamento, fusa?o, armazenamento e disponibilizac?a?o dessas informac?o?es. / Location systems have become increasingly part of people's lives. For outdoor environments, GPS appears as standard technology, widely disseminated and used. However, people usually spend most of their daily time in indoor environments, such as: hospitals, universities, factories, buildings, etc. In these environments, GPS does not work properly causing an inaccurate positioning. Currently, to perform the location of people or objects in indoor environments no single technology could reproduce for indoors the same result achieved by GPS for outdoors environments. Due to this, it is necessary to consider use of information from multiple sources using diferent technologies. Thus, this work aims to build an Adaptable Platform for Indoor location. Based on this goal, the IndoLoR platform is proposed. This platform aims to allow information reception from diferent sources, data processing, data fusion, data storage and data retrieval for the indoor location context.
4

Localização em ambientes internos utilizando PDR e Wi-Fi

Santos, Marco Aurélio dos, 9292212626 16 April 2018 (has links)
Submitted by marco aurélio santos (marrco.santos@gmail.com) on 2018-07-30T01:42:52Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) msc_dissertacao_marcoSantos.pdf: 6142716 bytes, checksum: 17219663e0f7676d5c438178de493d89 (MD5) / Approved for entry into archive by Secretaria PPGI (secretariappgi@icomp.ufam.edu.br) on 2018-07-30T18:34:28Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) msc_dissertacao_marcoSantos.pdf: 6142716 bytes, checksum: 17219663e0f7676d5c438178de493d89 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2018-07-31T18:29:17Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) msc_dissertacao_marcoSantos.pdf: 6142716 bytes, checksum: 17219663e0f7676d5c438178de493d89 (MD5) / Made available in DSpace on 2018-07-31T18:29:17Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) msc_dissertacao_marcoSantos.pdf: 6142716 bytes, checksum: 17219663e0f7676d5c438178de493d89 (MD5) Previous issue date: 2018-04-16 / Internal positioning systems allow the localization of people or certain objects indoors, as well as assist in navigation and orientation. Proposals for indoor location systems based on only one technology have achieved unsatisfactory performance in localization, mainly due to the limitations in relation to the conflicting characteristics present in these environments. This work aims at the development of a hybrid location system, integrating the PDR and Wi-Fi technologies, which aims to provide the location of a user in an internal environment, allowing the user to move around and visualize their current location through a representation on a map. The results were satisfactory, including the direct influence of factors such as: physical characteristics (height, body mass, size of the past), smartphone location, speed of the adopted march and adoption of constant movements. / Os sistemas de posicionamento internos permitem a localização de pessoas ou certos objetos em ambientes internos, assim como ajudam na navegação e orientação. As propostas de sistemas de localização para ambientes internos baseados em somente uma tecnologia tem alcançado desempenho insatisfatório na localização, principalmente, devido às limitações em relação às características conflitantes presentes nesses ambientes. Este trabalho tem como objetivo o desenvolvimento de um sistema híbrido de localização, integrando as tecnologias PDR e Wi-Fi, que visa fornecer a localização de um usuário em um ambiente interno, permitindo ao usuário locomover-se e visualizar a sua localização corrente através de uma representação em um mapa. Os resultados obtidos foram satisfatórios, constando-se a direta influência de fatores como: características físicas (altura, massa corporal, tamanho da passada) do usuário, localização do smartphone, velocidade da marcha adotada e adoção de movimentos constantes.
5

Avaliação da qualidade do ar em ambientes internos: biblioteca pública / Indoor air quality investigation: public library

Guilherme Caetano do Nascimento 01 April 2011 (has links)
Ao longo de quinze meses, foram monitorados na Biblioteca Pública Amadeu Amaral, da cidade de São Carlos, SP, os níveis de temperatura, umidade relativa, ruído, intensidade luminosa, contaminação por dióxido de carbono, material particulado total (MPT) e suas frações respiráveis (MP1, MP2,5, MP7 e MP10), avaliação da taxa de ventilação e ocupação, concentração de bioaerossóis e sua identificação. Além disso, foi aplicado um questionário aos ocupantes do local com o intuito de levantar as principais reclamações e queixas relacionadas à qualidade do ar interior. Os resultados mostraram o desconforto térmico do local em todas as salas monitoradas, altos níveis de ruído proveniente do ambiente externo, inadequações relativas à iluminação do local e necessidade de uma atenção especial à taxa de ocupação do prédio. Durante alguns momentos das medições, os níveis de ruído ultrapassaram a barreira dos 80 dB(A), que é um valor bem acima do recomendado em normas, revelando-se um fator de risco para seus usuários e funcionários. Não foram encontrados problemas relacionados à contaminação biológica do local, analisando a concentração de bactérias e fungos. A taxa de ventilação possui valor adequado para o piso 1 e a concentração de gás carbônico se manteve de acordo com os padrões estabelecidos em normas. As respostas dos questionários confirmam os principais resultados encontrados para a Biblioteca, como os altos níveis de ruído, o desconforto térmico do local e as inadequações da iluminação. As recomendações são pautadas na necessidade de realização de ensaios gravimétricos da concentração de material particulado e o desenvolvimento de estudos específicos para a adoção de medidas mitigadores da poluição sonora e, também, da adequação das salas para o conforto térmico dos ocupantes. / Over fifteen months, levels of temperature, humidity, noise, light intensity, contamination by carbon dioxide, total suspended particles (TSP) and respirable fractions (PM1, PM2.5, PM7 and PM10) were monitored at the Public Library Amadeu Amaral at São Carlos, SP. Investigation of the ventilation rate and occupancy, concentration of bioaerosols and identification were also performed. In addition, a questionnaire was handed over to the occupants of the site in order to raise the main complaints related to indoor air quality. The results showed the discomfort of the place at all rooms monitored, high levels of noise from the outside environment, inadequacies relating to the site illumination and special attention to the building occupancy. During some measurements, the noise levels exceeded the barrier of 80 dB (A), which is above the recommended standards and proved to be a risk factor for its users and employees. No problems were found related to the site biological contamination, analyzing the concentration of bacteria and fungi. The ventilation rate has adequate value to the first floor and carbon dioxide concentration was maintained in accordance with the standards. The questionnaire responses confirm the main findings to the library, such as high noise levels, thermal discomfort and the illumination problem. The main recommendations are based on the need of gravimetric particulate matter investigation and development of specific studies for the adoption of mitigation measures on noise pollution and also the suitability of the rooms to the thermal comfort of occupants.
6

Caracteriza??o de Cobertura de Sinais em Ambientes Internos com Mais de Um Pavimento na Faixa de 700 MHz

Santos, Alexandre Ferreira dos 23 November 2016 (has links)
Submitted by Alex Sandro R?go (alex@ifpb.edu.br) on 2016-11-23T17:29:43Z No. of bitstreams: 1 Caracteriza??o de Cobertura de Sinais - Alexandre Ferreira dos Santos.pdf: 2003492 bytes, checksum: 2fb564ef825a2732e63662f5c7c238dc (MD5) / Approved for entry into archive by Alex Sandro R?go (alex@ifpb.edu.br) on 2016-11-23T17:35:45Z (GMT) No. of bitstreams: 1 Caracteriza??o de Cobertura de Sinais - Alexandre Ferreira dos Santos.pdf: 2003492 bytes, checksum: 2fb564ef825a2732e63662f5c7c238dc (MD5) / Made available in DSpace on 2016-11-23T17:35:45Z (GMT). No. of bitstreams: 1 Caracteriza??o de Cobertura de Sinais - Alexandre Ferreira dos Santos.pdf: 2003492 bytes, checksum: 2fb564ef825a2732e63662f5c7c238dc (MD5) Previous issue date: 2016-11-23 / A demanda por comunica??es pessoais, que estabele?am conex?es nas mais diversas situa??es do dia-a-dia, est? estimulando o desenvolvimento de novas t?cnicas de rede que supram a necessidade dos usu?rios m?veis em rela??o ?s transmiss?es de voz e dados ao se movimentarem atrav?s de pr?dios, cidades ou pa?ses. Isso torna o estudo sobre a caracteriza??o da ?rea de cobertura fundamental. Logo, em ambientes internos com mais de um pavimento e quando n?o h? uma linha de visada entre o transmissor e o receptor a propaga??o depende da reflex?o, difra??o, refra??o e, em menor escala, da dispers?o da onda eletromagn?tica. Este trabalho tem como objetivo caracterizar a cobertura de sinais em ambientes internos com mais de um pavimento na faixa de frequ?ncia de 700 MHz, em virtude da sua destina??o para o uso dos sistemas de comunica??o em banda larga 4G/LTE no Brasil. Para se obter os resultados simulados foi desenvolvida uma planta em 3D reproduzindo os ambientes analisados. Em seguida a planta foi importada pelas ferramentas que comp?em a su?te WinProp? para a realiza??o das simula??es. Durante esta etapa, foi utilizada uma metodologia simplificada de predi??o de cobertura utilizando o m?todo do Tra?ado de Raios, onde foram considerados transmissores virtuais, posicionados no in?cio dos tr?s corredores analisados do pavimento superior, que consideraram como pot?ncias de sa?da as mesmas encontradas naqueles pontos ou locais, a partir da realiza??o da simula??o. Para a etapa experimental do trabalho foi desenvolvida uma base m?vel, em poliestireno expandido, para transportar o receptor ao longo dos ambientes analisados. As campanhas de medi??es foram realizadas, obtendo-se valores m?dios do sinal em intervalos regularmente espa?ados, para garantir uma menor influ?ncia do fen?meno de desvanecimento r?pido e uma maior espacialidade entre elas. Por fim, os resultados simulados, medidos e calculados a partir da f?rmula de Friis apresentaram um comportamento concordante.
7

Cacacteriza??o da Cobertura de Sinais na faixa de 700 MHZ em Ambientes Internos considerando os Efeitos da Polariza??o e do Azimute da Antena Diretiva

Fraz?o, Maria do Carmo de Luna Malheiros 06 December 2016 (has links)
Submitted by Alex Sandro R?go (alex@ifpb.edu.br) on 2016-12-06T13:13:30Z No. of bitstreams: 1 15- Maria do Carmo de Luna Malheiros Fraz?o - CARACTERIZA??O DA COBERTURA DE SINAIS NA FAIXA DE 700 MHZ EM AMBIENTES INTERNOS CONSIDERANDO OS EFEITOS DA POLARIZA??O E DO AZIMUTE D.pdf: 3902705 bytes, checksum: 36e170471d2e520bd62d1b40bdd640a9 (MD5) / Approved for entry into archive by Alex Sandro R?go (alex@ifpb.edu.br) on 2016-12-06T13:14:04Z (GMT) No. of bitstreams: 1 15- Maria do Carmo de Luna Malheiros Fraz?o - CARACTERIZA??O DA COBERTURA DE SINAIS NA FAIXA DE 700 MHZ EM AMBIENTES INTERNOS CONSIDERANDO OS EFEITOS DA POLARIZA??O E DO AZIMUTE D.pdf: 3902705 bytes, checksum: 36e170471d2e520bd62d1b40bdd640a9 (MD5) / Made available in DSpace on 2016-12-06T13:14:04Z (GMT). No. of bitstreams: 1 15- Maria do Carmo de Luna Malheiros Fraz?o - CARACTERIZA??O DA COBERTURA DE SINAIS NA FAIXA DE 700 MHZ EM AMBIENTES INTERNOS CONSIDERANDO OS EFEITOS DA POLARIZA??O E DO AZIMUTE D.pdf: 3902705 bytes, checksum: 36e170471d2e520bd62d1b40bdd640a9 (MD5) Previous issue date: 2016-12-06 / Com o aparecimento dos sistemas de comunica??o pessoal, tornou-se importante a caracteriza??o da propaga??o em ambientes fechados. A atenua??o no espa?o livre, a propaga??o por multipercurso e as intera??es que a onda mant?m com obst?culos s?o fen?menos mais relevantes associados ? propaga??o em ambientes interiores. Entretanto, se o canal indoor for bem caracterizado os efeitos das perdas de propaga??o eletromagn?ticas podem ser minimizadas, atrav?s da varia??o angular da antena do transmissor, a fim de encontrar a posi??o adequada para a localiza??o do transmissor. No contexto de uma rede sem fio, um ambiente interno difere de um ambiente externo em dois aspectos: menor raio de cobertura e maior variabilidade no ambiente. Constata-se, na pr?tica, que a propaga??o dentro de edifica??es ? influenciada por aspectos espec?ficos, tais como sua arquitetura e pelos materiais usados na constru??o. Nas ?ltimas d?cadas foram desenvolvidos e aperfei?oados v?rios modelos de predi??o que consideram as caracter?sticas do ambiente interno. O presente trabalho tem por objetivo estabelecer a caracteriza??o da cobertura de sinais de comunica??o sem fio em ambientes interiores na faixa de frequ?ncia em torno de 700 MHz. Essa banda foi escolhida devido a sua destina??o para ser utilizada pelos sistemas de comunica??o em banda larga 4G/LTE no Brasil. Os resultados simulados foram obtidos utilizando o programa comercial WinProp?, com base no m?todo do Tra?ado de Raios. Durante as simula??es foi proposto um m?todo simplificado de predi??o de cobertura, onde foram considerados transmissores virtuais, posicionados pr?ximos ?s paredes de in?cio de cada corredor transversal (situa??o sem visada entre transmissor e receptor), que consideraram como pot?ncias de sa?das as mesmas pot?ncias aferidas naqueles pontos ou locais, a partir do transmissor real. As campanhas de medi??es para a caracteriza??o experimental da cobertura de sinal foram realizadas, obtendo-se valores m?dios do sinal em intervalos regularmente espa?ados, de modo a se garantir uma menor influ?ncia do fen?meno de desvanecimento r?pido e uma maior espacialidade entre elas. Deste modo, os resultados obtidos mostraram uma boa concord?ncia entre os valores simulados, medidos e te?ricos, calculados a partir da f?rmula de Friis, nas situa??es com visada e sem visada direta.
8

Poluição do ar por compostos orgânicos voláteis (COV) em ambiente interno hospitalar / Air pollution by volatile organic compounds (VOCs) inside hospital

Petroni, Ivan Alexandre 07 August 2009 (has links)
A quantificação de 11 compostos carbonílicos (formaldeído, acetaldeído, acetona, acroleína, propionaldeído, crotonaldeído, butiraldeído, benzaldeído, isovaleraldeído, valeraldeído e 2,5-dimetilbenzaldeído) e a identificação de outros 43 compostos orgânicos voláteis (alcanos, alcenos, aromáticos, halogenados e nitrogenados) foram feitas em 9 ambientes diferentes de trabalho localizados em áreas internas do Hospital Universitário, USP, São Paulo. Dentre os compostos carbonílicos, os mais abundantes em ordem decrescente foram formaldeído, acetona, acetaldeído e acroleína. As maiores razões de mistura de formaldeído foram observadas nas salas de Macroscopia (169,9 e 90,2 ppbv) e Técnicas Histológicas (11,7 e 58,7 ppbv), em decorrência da atividade desenvolvida nos locais. Na sala de Macroscopia, os níveis de formaldeído encontrados foram acima do limite (100 ppbv) estabelecido por órgãos internacionais que controlam a qualidade do ar em ambientes internos não industriais. As razões de mistura entre o ambiente interno e o ambiente externo, razões I/E, permitiram indicar a predominância dos compostos carbonílicos nos ambientes internos. A acroleína foi encontrada na faixa de 6,4 a 9,3 ppbv nos ambientes internos estudados. Na área externa, entretanto, foram encontrados valores similares (6,4 e 6,8 ppbv) aos dos ambientes internos obtendo razões I/E próximas de 1. Os compostos podem ter sido emitidos por materiais de construção e acabamento, fumaça do tabaco, adesivos, via metabolismo microbiano e bacteriano ou podem ter sido transportados por correntes de ar do ambiente externo para o ambiente interno / The quantification of 11 carbonyl compounds (formaldehyde, acetaldehyde, acrolein, acetone, propionaldehyde, crotonaldehyde, butiraldehyde, benzaldehyde, isovaleraldehyde, valeraldehyde and 2,5-dimethylbenzaldehyde) and the identification of another 43 volatile organic compounds (alkanes, alkenes, aromatic, halogenated and nitrogenated compounds) have been done with samples of 9 different indoor places inside the University Hospital at USP in São Paulo. Among the carbonyl compounds, there where found higher quantities of formaldehyde, acetone, acetaldehyde and acrolein in this order. The highest ratios of formaldehyde mixture have been observed at the Macroscopic room (169.88 and 90.2 ppbv) and Histological Techniques (11.7 and 58.7 ppbv), due to the routine activities of these places. At the Macroscopy room, the level of formaldehyde identified (100 ppbv) was above the international limits established to non-industrial internal places. The ratios of the mixture of indoor and outdoor places, I/O, indicate the biggest presence of carbonyl compounds in internal places. Acrolein has been identified (6.4 to 9.3 ppbv) at indoor places. At the external area, there where found similar values (6,4 to 6,8 ppbv), and the ratio I/O obtained is near to 1. The origin of these compounds is possibly construction materials, smoke of cigarettes, adhesives, metabolism of microorganisms or they may have come from the outdoor to the indoor
9

Poluição do ar por compostos orgânicos voláteis (COV) em ambiente interno hospitalar / Air pollution by volatile organic compounds (VOCs) inside hospital

Ivan Alexandre Petroni 07 August 2009 (has links)
A quantificação de 11 compostos carbonílicos (formaldeído, acetaldeído, acetona, acroleína, propionaldeído, crotonaldeído, butiraldeído, benzaldeído, isovaleraldeído, valeraldeído e 2,5-dimetilbenzaldeído) e a identificação de outros 43 compostos orgânicos voláteis (alcanos, alcenos, aromáticos, halogenados e nitrogenados) foram feitas em 9 ambientes diferentes de trabalho localizados em áreas internas do Hospital Universitário, USP, São Paulo. Dentre os compostos carbonílicos, os mais abundantes em ordem decrescente foram formaldeído, acetona, acetaldeído e acroleína. As maiores razões de mistura de formaldeído foram observadas nas salas de Macroscopia (169,9 e 90,2 ppbv) e Técnicas Histológicas (11,7 e 58,7 ppbv), em decorrência da atividade desenvolvida nos locais. Na sala de Macroscopia, os níveis de formaldeído encontrados foram acima do limite (100 ppbv) estabelecido por órgãos internacionais que controlam a qualidade do ar em ambientes internos não industriais. As razões de mistura entre o ambiente interno e o ambiente externo, razões I/E, permitiram indicar a predominância dos compostos carbonílicos nos ambientes internos. A acroleína foi encontrada na faixa de 6,4 a 9,3 ppbv nos ambientes internos estudados. Na área externa, entretanto, foram encontrados valores similares (6,4 e 6,8 ppbv) aos dos ambientes internos obtendo razões I/E próximas de 1. Os compostos podem ter sido emitidos por materiais de construção e acabamento, fumaça do tabaco, adesivos, via metabolismo microbiano e bacteriano ou podem ter sido transportados por correntes de ar do ambiente externo para o ambiente interno / The quantification of 11 carbonyl compounds (formaldehyde, acetaldehyde, acrolein, acetone, propionaldehyde, crotonaldehyde, butiraldehyde, benzaldehyde, isovaleraldehyde, valeraldehyde and 2,5-dimethylbenzaldehyde) and the identification of another 43 volatile organic compounds (alkanes, alkenes, aromatic, halogenated and nitrogenated compounds) have been done with samples of 9 different indoor places inside the University Hospital at USP in São Paulo. Among the carbonyl compounds, there where found higher quantities of formaldehyde, acetone, acetaldehyde and acrolein in this order. The highest ratios of formaldehyde mixture have been observed at the Macroscopic room (169.88 and 90.2 ppbv) and Histological Techniques (11.7 and 58.7 ppbv), due to the routine activities of these places. At the Macroscopy room, the level of formaldehyde identified (100 ppbv) was above the international limits established to non-industrial internal places. The ratios of the mixture of indoor and outdoor places, I/O, indicate the biggest presence of carbonyl compounds in internal places. Acrolein has been identified (6.4 to 9.3 ppbv) at indoor places. At the external area, there where found similar values (6,4 to 6,8 ppbv), and the ratio I/O obtained is near to 1. The origin of these compounds is possibly construction materials, smoke of cigarettes, adhesives, metabolism of microorganisms or they may have come from the outdoor to the indoor
10

[pt] DESENVOLVIMENTO DE SISTEMA DE MONITORAMENTO MULTIPARAMÉTRICO DA QUALIDADE DO AR EM AMBIENTES INTERNOS / [en] DEVELOPMENT OF A MULTIPARAMETRIC INDOOR AIR QUALITY MONITORING SYSTEM

THIAGO LEITE CAVALCANTE 10 June 2021 (has links)
[pt] O tema qualidade do ar em ambientes internos é de suma importância para a sociedade devido ao seu impacto na saúde humana, e pela maior permanência de indivíduos em ambientes sem circulação de ar natural. Este trabalho descreve o desenvolvimento de um sistema portátil e de baixo custo para monitoramento de grandezas atmosféricas ligadas à qualidade do ar em ambientes internos, composto por sensores integrados a unidades locais, incluindo um sistema remoto hospedado na nuvem para armazenar os resultados das medições desses sensores. Apresentam-se as diretrizes e documentos normativos e regulatórios relacionados ao tema, além das tecnologias para sensoriamento utilizadas. Após o desenvolvimento e caracterização dos sensores, as unidades foram distribuídas em ambientes universitários com distintas dinâmicas de uso, onde o gradiente espacial das grandezas atmosféricas foi avaliado e analisado segundo os requisitos para qualidade do ar publicados na regulamentação vigente. Com o monitoramento multiparamétrico identificou-se a heterogeneidade da distribuição dos valores das grandezas, dependente da dinâmica de ocupação e das condições de ventilação, especialmente para as concentrações de CO2. Este parâmetro superou os valores recomendados pela agência reguladora em todos os ensaios realizados em sala de aula, e maiores valores mostraram-se fortemente associados à região do espaço mais próxima das vias aéreas superiores dos ocupantes. Os resultados apontam para a importância de monitoramento contínuo e em vários pontos de um plano posicionado a uma distância estratégica do piso, conforme a dinâmica de ocupação e posição média da emissão de gases pelo processo respiratório. / [en] The topic of indoor air quality is of paramount importance to society due to its impact on human health and the increasing number of individuals staying in environments with no natural air circulation. This work describes the development of the system, low-cost and portable, for monitoring atmospheric quantities linked to indoor air quality, composed of sensors integrated into local units, including a remote system hosted in the cloud to store the results of measurements of these sensors. The normative and regulatory guidelines and documents related to the theme are presented, in addition to the sensing technologies used. After the development and characterization of the sensors, the units were distributed in university environments with different dynamics of use, where the spatial gradient of the atmospheric quantities was evaluated and analyzed according to the requirements for air quality published in the current regulation. With multiparametric monitoring, the heterogeneity of the distribution of the values of the quantities was identified, depending on the dynamics of occupation and ventilation conditions, especially for CO2 concentrations. This parameter exceeded the values recommended by the regulatory agency in all tests performed in the classroom, and higher values were shown to be strongly associated with the region of space closest to the occupants upper airways. The results point to the importance of continuous monitoring and at various points in a plane positioned at a strategic distance from the floor, according to the dynamics of occupation and the average position of the emission of gases by the respiratory process.

Page generated in 0.1693 seconds