• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 206
  • 26
  • 25
  • 25
  • 25
  • 19
  • 6
  • 5
  • 5
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 224
  • 224
  • 224
  • 134
  • 111
  • 110
  • 59
  • 58
  • 45
  • 44
  • 43
  • 42
  • 35
  • 32
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação das tensões geradas nos componentes protéticos de próteses obturadoras maxilares classe I, II e IV de Aramany por meio de análise de elementos finitos / Evaluation of stress generated in maxillar obturators prosthesis of class I, II and IV of Aramany in Finite Element Analysis

Elcio Ricardo Miyashita 20 March 2013 (has links)
O tratamento cirúrgico do câncer bucal pode resultar em graves sequelas das estruturas anatômicas envolvidas na fisiologia da cavidade bucal. A extensão e a localização da ressecção cirúrgica, assim como a condição dental, são determinantes do planejamento da prótese obturadora. Este trabalho emprega a Análise de Elementos Finitos para o estudo do comportamento biomecânico de próteses obturadoras maxilares Classe I, II e IV de Aramany, em um modelo digital desenvolvido a partir de uma TC de um indivíduo adulto. O modelo tridimensional desenvolvido no programa Rhinoceros® versão 4.0 foi utilizado para a geração da malha de elementos finitos no programa Ansys Workbench 14.0®. Uma força de 120 N foi aplicada nas plataformas oclusal e incisal, correspondentes aos dentes posteriores e anteriores das próteses obturadoras, para observação das tensões geradas sobre as próteses obturadoras. Os resultados são apresentados sob a forma de análise qualitativa, indicada pelo estudo de Tensão Máxima Principal para as estruturas acrílicas da prótese e estudo de Von Mises para as estruturas metálicas da prótese, e análise quantitativa, representada por valores em Mega Pascal (MPa). Tanto nos carregamentos posteriores como nos carregamentos anteriores, foram observadas dissipações de cargas significativas localizadas na placa palatina próxima a ressecção e na junção do metal com o acrílico, sendo os maiores valores alcançados na placa de retenção metálica para retenção do acrílico localizada posteriormente na condição de carregamento posterior em ordem crescente na Classe II de Aramany com 149,17 MPa, Classe I de Aramany com 344,08 MPa e Classe IV de Aramany alcançando valor de 390,25 MPa. No acrílico da prótese obturadora, no caso de Classe I de Aramany em carregamento posterior, foi observada uma concentração de tensão principal na região correspondente ao limite lateral e anterior da junção da placa de retenção e do acrílico no valor de 19,796 MPa de tração. Na Classe IV de Aramany em carregamento posterior, foi observada uma concentração de tensão na região posterior da junção da placa de retenção e do acrílico no valor de 18,33 MPa. Na Classe II de Aramany, em carregamento posterior foi observada uma concentração de tensão na região anterior próxima ao limite da ressecção anterior no valor de 25,45 MPa de tração. Concluiu-se que os valores quantitativos alcançados neste estudo parecem não apresentar riscos de fratura sobre a armação metálica de liga de CrCo, porem podem apresentar riscos de falha na retenção metal/acrílico da prótese obturadora maxilar. A configuração de placa de recobrimento palatino proporciona uma melhor distribuição das tensões ao longo de sua superfície. / The surgical treatment of oral cancer may result in severe sequel of the anatomical structures involved in oral physiology. The extension and location of surgical resection, as well as the dental condition, determine the prosthetic planning of the obturator prostheses. This study employs the finite elements analysis to evaluate the biomechanical behavior of Aramany Class I,II andIV obturator prostheses, in a digital model developed from a computerized tomography of an adult individual. A tridimensional model was constructed applying the software Rhinoceros® version 4.0 and then it was used to develop the finite element mesh in the software Ansys Workbench 14.0 ®. A 120 N load was applied to the occlusal and incisal surfaces correspondent to the prosthetic teeth. The qualitative analysis was based on Principal Maximum stress and the quantitative analysis was expressed in Mega Pascal values. Results demonstrated that in the posterior loadings as in the anterior loadings were observed charge dissipation plate located in significant palate resection and near the junction of the metal with the acrylic and the highest values obtained in the metal retaining plate for retaining acrylic located further provided that subsequently loaded in ascending order in Class II Aramany with 149.17 MPa, Aramany with Class I and Class IV 344.08 MPa Aramany reaching value of 390.25 MPa. In acrylic prosthesis obturator in the case of Class I Aramany in subsequent loading, was observed a stress concentration in the region corresponding to the limit lateral and anterior junction of the retaining plate and the value of acrylic 19.796 MPa. Class IV for loading Aramany later, it was observed a stress concentration in the posterior region of the junction of the retaining plate of acrylic and the value of 18.336 MPa. In Class II Aramany in load was later observed a stress concentration in the anterior region near the boundary of the anterior resection worth 25.455 MPa. It was concluded that the quantitative values obtained in this study do not appear to present a risk of fracture of the metal frame CrCo alloy, but may present risks of failure in the metal retention / acrylic obturator prostesis . The configuration of palatal plate coating provides a better stress distribution along its surface.
72

Análise por meio do método dos elementos finitos de um protetor bucal para atividades esportivas / Analysis through the finite element method of a mouthguard for sports activities

Poblete, Felipe Andres Ortiz 01 July 2011 (has links)
O uso de protetores bucais na prática de esportes tem ampliado espaço no contexto da prevenção de traumas bucais, bem como apresentado melhoria no desempenho ao longo de sua história. O objetivo deste trabalho foi avaliar o comportamento do complexo buco dento alveolar (lábio, dentes, osso alveolar e ligamento periodontal) por meio do método dos elementos finitos. A metodologia utilizada foi a partir de um modelo em formato esterolitográfico oriundo de uma tomografia computadorizada, o qual foi convertido para um modelo 3D pelo programa Rhinoceros® versão 4.0 sem protetor bucal (controle) e com protetor bucal de 4.0mm de espessura em EVA (copolímero de etileno e acetato de vinila), os quais receberam três cargas diferentes (500, 1000 e 1500N) no programa ANSYS® v12 em regime quaseestático, de caráter elástico linear. Pudemos observar que houve um padrão de comportamento das estruturas envolvidas quanto à dissipação das tensões geradas e ao se comparar o modelo controle com o modelo provido de protetor bucal houve uma absorção das tensões geradas em até 50%, permitindo confirmar a ação do protetor bucal em literatura e tornando o seu uso imperativo durante a prática de esportes, em especial as modalidades de maior contato. / The use of mouthguards in the practice of sports has expanded space in the prevention of oral trauma, and presented performance improvement over its history. The aim of this study was to evaluate the behavior of complex buco dental alveolar (lip, teeth, periodontal ligament and alveolar bone) through the finite element method. The methodology used was based on a sterelithographic model come from a CT scan, which was converted to a 3D model by the program Rhinoceros® version 4.0 without a mouthguard (control) and mouthguard 4.0mm-thick EVA (copolymerof ethylene and vinyl acetate), which received three different loads (500, 1000 and 1500N) in ANSYS® v12 under quasi-static, linear elastic character. We noticed that there was a pattern of behavior of the structures involved and the dissipation of the tensions generated and compare the model with the control model was fitted with a mouthguard absorbs stresses generated by 50%, allowing to confirm the action of the mouthguard in literature and making its use mandatory for participation in sports, in particular the modalities for greater contact.
73

Análise biomecânica de próteses implantossuportadas variando a conexão, o sistema de retenção, material restaurador, tipo e o nível do tecido ósseo. Estudo pelo método dos elementos finitos tridimensionais /

Lemos, Cleidiel Aparecido Araujo. January 2019 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: Fellippo Ramos Verri / Banca: Aldiéris Alves Pesqueira / Banca: Leonardo Perez Faverani / Banca: Estevão Tomomitsu Kimpara / Banca: Eduardo Miyashita / Resumo: Este projeto teve como objetivo analisar as tensões geradas em próteses implantossuportadas fixa unitária variando o sistema de conexão implante/prótese, o sistema de retenção, material restaurador, tipo ósseo, e o nível de tecido ósseo ao redor do implante através do método dos elementos finitos tridimensionais, e realizar uma revisão sistemática com meta-análise sobre o tema osteoporose em relação a taxa de sobrevivência e perda óssea marginal ao redor dos implantes dentários. Em relação à metodologia experimental, foram simulados 24 modelos tridimensionais com ajuda dos programas de desenho assistido Rhinoceros 3D 4.0 (NURBS Modeling for Windows, USA) e SolidWorks 2011 (SolidWorks Corp, USA), e para confecção da porção óssea será utilizado o programa InVesalius (CTI, São Paulo, Brasil). Cada modelo representou uma secção de osso da região posterior maxilar, na forma de um bloco ósseo tipo IV (normal e osteoporótico), variando o nível de reabsorção do tecido ósseo (a nível do pescoço do implante; perda de 1,5 mm; perda de 3,0 mm; e perda de 4,5 mm) com a presença de um implante de 4,0 mm de diâmetro e 10 mm de comprimento com diferentes tipos de conexão (hexágono externo e cone morse), restaurado com coroas (metalocerâmicas e/ou metal free) com diferentes sistemas de retenção (cimentada e/ou parafusada). Os desenhos tridimensionais foram exportados ao programa de pré e pós processamento FEMAP v.11.2 (Siemens Product Lifecycle Management Software Inc. USA) para geração da ma... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this thesis was to perform the analysis on the stress distribution for implant-supported fixed prostheses varying the implant-abutment connection system, the fixation system, restorative material, bone type, and the level of bone tissue around the dental implant using the finite element method. Furthermore, the aim was to perform a systematic review and meta-analysis about the effect of osteoporosis in terms of implants survival rate and marginal bone loss. In relation to the experimental methodology, 24 three-dimensional models were simulated with the aid of the Rhinoceros 3D 4.0 (NURBS Modeling for Windows, USA), SolidWorks 2011, and InVesalius (CTI, São Paulo, Brazil) softwares. Each model represented a bone section of the maxillary posterior area (bone type IV) (normal and osteoporotic), varying the level of bone resorption (at the level of the implant, loss of bone tissue in 1.5 mm, loss of bone tissue in 3.0 mm and loss of bone tissue in 4.5 mm). All models containing the presence of a dental implant with 4.0 mm in diameter and 10 mm in length with two different abutment-implant connection (external hexagon and Morse taper), restored with crowns (metaloceramic and/or monolithic) with different fixation system (cemented and/or screwed). The designs were exported to FEMAP v.11.2 pre-and postprocessing software (Siemens Product Lifecycle Management Software Inc. USA) for mesh generation and loading application of 200N axial and 100N oblique (45° in the long axis... (Complete abstract click electronic access below) / Doutor
74

Modelagem Matemática do Aquecimento Indutivo de Barras de Aço Utilizadas na Produção de Hastes de Bombeio /

Tana, Luiz Fernando Bissoli. January 2016 (has links)
Orientador: Maurício Araújo Zanardi / Banca: José Antonio Perrella Balestieri / Banca: José Rui Camargo / Resumo: Neste trabalho, aborda-se a modelagem por elementos finitos de um aquecimento indutivo de barras de aço utilizadas no forjamento de hastes de bombeio, tendo como principal objetivo avaliar a variação de temperatura radial da barra de aço aquecida pelo indutor e o impacto das propriedades envolvidas no aquecimento. Uma apresentação do processo de produção de uma haste de bombeio é efetuada, descrevendo as etapas de produção, sendo o aquecimento indutivo a etapa em estudo. A técnica de aquecimento por indução trata-se de um processo com alto grau de repetição e alto volume de produtividade, utilizada para aquecimento de peças dos mais diversos formatos, sendo amplamente empregada na indústria. A base para a modelagem matemática é feita por meio das quatro equações de Maxwell relacionadas às propriedades magnéticas dos materiais. O método utilizado para os elementos finitos é de Resíduos Ponderados (Galerkin) que possui grande aproximação dos resultados. É feito um detalhamento da modelagem matemática do método aplicado no programa utilizado / Abstract: In this work, it is made an approach of finite elements modeling of an induction heating of steel bars used to forging sucker rods, seeking as the main goal to evaluate the radial thermal variation inside the bar heated by the inductor, since the impact of the variation of properties related to the heating process. A brief presentation of the production process is presented, describing all the productions steps, with the induction heating being the focus of the study. The technique of induction heating is a procedure with high repeatability and high volume productivity used for heating pieces of various kinds of formats, being widely employed in industry. The basis for the mathematical modeling is made using the four Maxwell equations related to the magnetic properties of materials. The method used to solve the equation was the finite element residues (Galerkin) which has great approximation of the results. It was made a detailed mathematical modeling of the method applied in the software used / Mestre
75

Identificação de parâmetros em sistemas rotativos utilizando funções de otimização e observadores de estado /

Oliveira, Lucas Rangel de. January 2015 (has links)
Orientador: Gilberto Pechoto de Melo / Banca: Luiz de Paula do Nascimento / Banca: Gregory Bregion Daniel / Resumo: Uma máquina rotativa é composta por muitos componentes interconectados que atuam em conjunto. Essa influência mútua pode ocasionar uma grande variedade de fenômenos durante seu funcionamento. Desbalanceamento, desalinhamento e falha em mancais de rolamento são os principais responsáveis pela vibração desses equipamentos. Uma das soluções para evitar tais problemas é o monitoramento constante de máquinas a fim de antever um dano mais grave. Nesse ambiente, há a preocupação no desenvolvimento de novas técnicas de detecção e localização de falhas. Uma das técnicas mais difundidas atualmente é a identificação de rigidez e amortecimento dos mancais e de forças de excitação do sistema. Para o desenvolvimento dessas metodologias há a necessidade de construção de modelos matemáticos capazes de representar o comportamento mecânico, sendo úteis na previsão da resposta do sistema. Neste âmbito, este projeto tem como proposta estimar a rigidez e o amortecimento dos mancais - a partir de dados experimentais - e identificar as forças de desbalanceamento utilizando três métodos diferentes: séries de Fourier, polinômios de Legendre e de Chebyshev / Abstract: A rotating machine is composed of many interconnected components working together. This mutual influence can cause a wide range of phenomena during operation. Unbalancing, misalignment and failure in ball bearings are mainly responsible for the vibration of such equipment. One solution to avoid such problems is the constant monitoring of machines in order to predict a more severe damage. In this environment, there is concern in the development of new techniques for detection and troubleshooting. One of the techniques is now widespread the identification of stiffness and damping of the bearing and the excitation forces of the system. For the development of these methods is the need to build mathematical models that represent the mechanical behavior and is useful in predicting system response. In this context, this project proposes the estimation of stiffness and damping of the bearings - from experimental data - and the identification of unbalance forces using three different methods: Fourier series, Legendre polynomials and Chebyshev / Mestre
76

Comportamento mecânico de implantes modificados na região de ápice : análise pelo método de elementos finitos, fotoelasticidade, torque de inserção e frequência de ressonância /

Sciasci, Plínio. January 2017 (has links)
Orientador: Luís Geraldo Vaz / Resumo: A proposta deste estudo foi analisar o comportamento mecânico e a distribuição de forças de diferentes geometrias de ápice em implantes cilíndricos por meio de método de elementos finitos (MEF), fotoelasticidade, torque de inserção e frequência de ressonância. Foram usinados quatro tipos de implantes: sem corte apical (A), com corte apical bi-partido (B), corte apical tri-partido (C), corte apical quadri-partido (D) e um quinto (grupo controle) implante Titamax Ti Ex (Neodent, Curitiba, Paraná, Brasil) (E), todos com dimensões (4,1 X 11,0 mm) de plataforma hexagonal externa. Para o ensaio fotoelástico, blocos de acrílico (30X30X10mm) com um implante foram copiados com Borracha Silicone. Dentro de cada molde de silicone foi vertido resina fotoelástica semi-fexível. Para o ensaio fotoelástico duas situações foram simuladas: aplicação de carga axial de 1 kgf e em outro momento aplicação do torque de 10 N.cm. As fotografias realizadas no polariscópio circular foram transferidas para um computador para leitura dos parâmetros fotoelásticos no software powerpoint (Office 2010). Para o estudo de elementos finitos, o desenho dos implantes foram reproduzidos em CAD (computer Aided design) através do software Autodesk Inventor® (versão 2015, São Paulo, Brasil) e o bloco ósseo tipo IV de dimensões (2X2X2cm) foram posteriormente processados pelo software Rhinoceros v5.0 SR8 (McNeel North America, Seattle, WA, USA). As simulações foram executadas pelo software (Ansys Workbench 10.0, Swanso... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to analyze the mechanical behavior and force distribution of five different implant designs using finite element method (FEM), photoelasticity, insertion torque and resonance frequency of different geometric modifications proposed for the apex region Of cylindrical implants. Four types of implants were machined: without apical cut (A), with a two-part apical cut (B), apical tri-split cut (C), apical cut quadri-split (D) and fifth group was composed by Titamax Ti Ex Neodent all with dimensions (4.1 X 11.0 mm). For the photoelastic test, acrylic blocks (30X30X10mm) with implant installed were copied with Blue ASB-10 Silicone Rubber (Polipox). Inside each silicone mold was poured semi-flexible photoelastic resin (Polipox). A titanium UCLA prosthetic intermediate was screwed onto the implant and a dental crown on (Ni-Cr) was fixed on the set. For the photoelastic test two situations were simulated: application of axial load of 1 kgf and torque of 10 N.cm. The photograph and the reading of the photoelastic parameters were performed in a circular polariscope. For the finite element study, the computerAided design (CAD) implants and a Type IV human bone block of dimensions (2X2X2cm) were processed by the software Rhinoceros v5.0 SR8 (McNeel North America, Seattle, WA, USA) At the Renato Archer Information Technology Center (CTI, Campinas, São Paulo - Brazil). The mechanical properties of the implant (titanium grade II) and normal bone type IV were obtai... (Complete abstract click electronic access below) / Doutor
77

Estudo comparativo de diferentes mini-implantes utilizados para mesialização de segundo molar inferior: análise por elementos finitos 3d / Study of different mini-implants used for lower molar mesialização: Analysis by finite elements 3d

Lisboa, Juliana da Costa 13 July 2018 (has links)
Submitted by Juliana da Costa Lisbôa (julianalisboa86@hotmail.com) on 2018-09-10T11:26:11Z No. of bitstreams: 1 Juliana C Lisboa.pdf: 1704367 bytes, checksum: 0a852a606d663babe8ff1cd313f64b57 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-09-10T19:21:58Z (GMT) No. of bitstreams: 1 lisboa_jc_me_sjc.pdf: 1704367 bytes, checksum: 0a852a606d663babe8ff1cd313f64b57 (MD5) / Made available in DSpace on 2018-09-10T19:21:59Z (GMT). No. of bitstreams: 1 lisboa_jc_me_sjc.pdf: 1704367 bytes, checksum: 0a852a606d663babe8ff1cd313f64b57 (MD5) Previous issue date: 2018-07-13 / A perda do primeiro molar é uma situação comum na rotina do consultório e com isso surgem alternativas de tratamento para reabilitação, sendo uma delas, o fechamento de espaço através da mesialização do segundo molar. O uso de mini- implante proporciona ancoragem máxima, costuma ser bem tolerado pelo paciente e se destaca pela facilidade de instalação e remoção, apresentando dessa maneira desempenho clínico bastante favorável. O objetivo desse estudo foi analisar a distribuição de tensões em modelo que simula a mesialização de molar inferior utilizando diferentes tipos de mini-implantes. Embasado no método dos elementos finitos foi obtido modelo ósseo de mandíbula por recomposição de uma tomografia computadorizada realizada pelo software Invesalius (CTI, São Paulo, Brasil). O desenho do segundo molar foi obtido por técnica de recomposição tomográfica. Elementos de ancoragem auto-perfurantes da marca Neodent e também auto-rosqueantes da marca Titanium Fix foram desenhados e modelados por ferramenta de revolução do perfil desenhado no software Rhinoceros 3D, inseridos ao bloco ósseo e então submetidos a cargas de 200 cN. Os resultados foram calculados e analisados pelo programa Ansys 17.0 para verificação por meio da análise de mapas de deslocamento e tensões máximas principais, principalmente do osso cortical e indicaram que, dentro do modelo experimental, o ligamento periodontal apresentou valores baixos de tensão máxima principal, porém dentro dos valores fisiológicos para prover a movimentação, com visualização de áreas de compressão e de tração com escala entre 0,1 a -0,1 MPa. Concluiu-se que a carga testada permite a deslocamento dentário porém com tendência a giroversão. / The loss of the first molar is a common situation in the routine of the dentist and with this treatment alternatives for rehabilitation arises, one of them being the closure of space through the mesialization of the second molar. The use of mini-implants provides maximum anchorage, is well tolerated by the patient and stands out for ease installation and removal, thus presenting a very favorable clinical performance. The objective of this study was to analyze the stress distribution in a model that simulates the inferior molar mesialization using different types of mini- implants. Based on the finite element method, a mandible bone model was obtained by recomposing a computerized tomography performed by invesalius software (CTI, São Paulo, Brazil). The second molar design was obtained by a technique similar to the tomographic recomposition. Neodent self-piercing anchoring elements and also Titanium Fix self-piercing anchors were designed and modeled by a revolution tool in the Rhinoceros 3D software, inserted into the bone block and then subjected to loads of up to 200 cN. The results were calculated and analyzed by the Ansys 17.0 program for verification by means of the analysis of displacement maps and main maximum stresses, mainly of the cortical bone and indicated that, within the experimental model, the periodontal ligament presented low values of main maximum tension, however within the physiological values to provide the movement, with visualization of areas of compression and traction with scale between 0.1 and -0.1 MPa. It was concluded that the load tested allows dental displacement but with a tendency to gyroversion.
78

Avaliação da distribuição das forças produzidas com arco lingual removível pelo método de elementos finitos / Evaluation of the forces produced with removable lingual arch by finite element method

Mendes, Matheus Strelow [UNESP] 27 January 2016 (has links)
Submitted by Matheus Mendes (matheus.strelow@hotmail.com) on 2016-03-18T18:31:23Z No. of bitstreams: 1 Dissertacao Matheus ultima versao.pdf: 1399576 bytes, checksum: 4c2bad16d434d17db1ee6f928b75c478 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-03-22T12:20:11Z (GMT) No. of bitstreams: 1 mendes_ms_me_arafo.pdf: 1399576 bytes, checksum: 4c2bad16d434d17db1ee6f928b75c478 (MD5) / Made available in DSpace on 2016-03-22T12:20:11Z (GMT). No. of bitstreams: 1 mendes_ms_me_arafo.pdf: 1399576 bytes, checksum: 4c2bad16d434d17db1ee6f928b75c478 (MD5) Previous issue date: 2016-01-27 / Avaliar as forças ortodônticas liberadas pelo arco lingual por meio do Método de elementos Finitos nos dentes molares inferiores. MËTODO: Através da criação de um modelo geométrico computacional, com metodologia e softwares específicos, é possível o estudo do desempenho de estruturas através do método de análise com elementos finitos. Foi utilizada uma tomografia da região da mandíbula, em cortes de 0.25 mm de altura, para um total de 428 cortes com 640 x 640 voxels cada. O exame foi salvo no formato DICOM (Digital Imaging and Communications in Medicine Standard) e importado para um programa de processamento de imagem e reconstrução digital (Simpleware 4.2, Simpleware Ltd, Exeter, United Kingdom), para obtenção das geometrias desejadas, os dentes e a superfície óssea externa foram segmentados manualmente e reconstruídos tri dimensionalmente num modelo não paramétrico, gravados no formato STL (3D Systems, Rock Hill, USA). Para possibilitar a edição posterior, mas sem distorção significativa, os modelos foram parametrizados através do programa Solidworks Premium “Scan to 3D” (Dassault Systemes, Solidworks Corps, USA). Foi confeccionado um modelo em três dimensões do dispositivo ortodôntico arco lingual através do mesmo programa. Uma simulação da ativação do arco lingual foi realizada com o programa de simulação de elementos finitos Ansys Workbench V11. (Ansys Inc., Canonsburg, PA, USA) e os resultados relativos as pressões recebidas pelo dente e ligamento periodontal foram analisados através de plotagens gráficas e numéricas. RESULTADOS: A ativação do arco lingual provocou uma movimentação no sentido mesio-lingual nos dentes molares,ao final da simulação os dentes molares tiveram uma movimentação de até 3,59 µm e o pico de pressão entre ligamento periodontal e dentina nos primeiros molares foi de 0,44 MPa. Já as tensões recebidas pelo fio de aço do arco lingual foram de até 2136 MPa. CONCLUSÃO: O Método de Elementos Finitos, é capaz de identificar as áreas de tensão do fio do arco lingual, ligamento periodontal e dente. As áreas de maior tensão na ativação bilateral do arco lingual localizaram-se próximas as bifurcações dos primeiros molares. / Evaluate the orthodontic forces released by the lingual arch through the finite elements method in lower molar teeth. Method: creating a computational geometric model with methodology and specific software the study of structural performance through the analysis of finite element method is possible. A tomographic scan of mandible was used in 0.25 mm high cuts to a total of 428 sections with 640 x 640 voxels each. The data was saved in DICOM (Digital Imaging and Communications in Medicine standard) and imported into an image processing program and digital reconstruction (Simpleware 4.2 Simpleware Ltd, Exeter, United Kingdom), to obtain the desired geometry, the teeth and the external bone surface were manually segmented and reconstructed three dimensionally in a non-parametric model, written in STL format (3D Systems, Rock Hill, USA). The models were parameterized by program Solidworks Premium "Scan to 3D" (Dassault Systemes, Solidworks Corps, USA). A model was made in three dimensions of the lingual arch orthodontic appliance using the same program. A simulation of the lingual arch activation was conducted with the simulation with ANSYS finite element Workbench V11. program (Ansys Inc., Canonsburg, PA, USA) and the results for the pressures received by the tooth and periodontal ligament were analyzed through graphical and numerical plots. RESULTS: the activation of lingual arch caused a movement in the mesio lingual direction, the molar teeth had a movement of 3.59 µm and the highest pressure between periodontal ligament and dentin in the first molars was 0, 44 MPa. Tensions received by the steel wire of lingual arch were up to 2136 MPa. CONCLUSION: The Finite Element Method, is able of identifying the areas of tension on wire lingual arch, tooth and periodontal ligament. The areas of greatest tension in lingual arch bilateral activation were located near the forks of the first molars.
79

Estudo de preparos e da forma da infraestrutura na distribuição de tensões em prótese parcial fixa

Yamamoto, Eron Toshio Colauto [UNESP] 06 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-06Bitstream added on 2014-06-13T19:20:23Z : No. of bitstreams: 1 yamamoto_etc_dr_sjc.pdf: 2267197 bytes, checksum: 537fb4ee2e9f4f60f9c4e4cdae9ad336 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi verificar o comportamento de prótese fixa de três elementos confeccionada em Zircônia e dos dentes suportes quando são utilizados diferentes preparos dos dentes suportes e diferentes formas da infra-estrutura. Simulou-se a ausência do segundo pré-molar superior e realizou-se preparos do tipo ocluso-proximal, proximal-ocluso-proximal, preparo para overlay e para coroa total nos dentes suportes. Utilizou-se dois tipos de formato de conector, o convencional e em forma de arco. Os modelos tridimensionais foram realizados em softwares CAD Rhinoceros® e 3D Studio Max®. Os modelos tridimensionais simularam uma secção da maxila na região entre primeiro pré-molar e primeiro molar e foram compostos por osso medular e cortical, ligamento periodontal, dentina e esmalte. Foi realizada análise de elementos finitos, as análises de tensões foram processadas no programa Ansys®. Os resultados foram apresentados por meio de mapas de cores de tensão/deformação, com a distribuição de tensões e valores numéricos. Os diferentes preparos dos dentes suportes não influenciaram na distribuição de tensões nos dentes suportes. O preparo de coroa total foi o único preparo que diminui a tensão sobre a infra-estrutura. O formato do conector foi significativamente diferente. O conector em forma de arco distribui melhor as tensões na infra-estrutura do que o conector convencional / The aim of this study was to investigate the behavior of three elements fixed partial denture made of three elements made of Zirconia and support teeth when use different preparations of the support teeth and different forms of framework. Simulated the absence of the superior second premolar and the support teeth preparation was occlusal-proximal, proximal-occlusal-proximal, overlay preparation and full crown. We used two types of connector format, the conventional and arc-shaped. The three-dimensional models were made in Rhinoceros CAD software and 3D Studio Max. The model was composed with maxillary first premolar and first molar, cortical and medullary bone, periodontal ligament, dentin and enamel. Analyses of stresses were processed in the program ANSYS ®. The results were presented in color maps of stress / strain, with the stress distribution and numerical values. The different preparations of the support teeth didn´t influence the stress distribution in supppot teeth. The preparation of full crown was the only preparation that reduces the strain on the infrastructure. The shape of the connector was significantly different. The arch-shaped connector was better than conventional connector in the framework stress distribution
80

Platform switching : avaliação biomecânica por meio do método de elementos finitos tridimensional /

Tabata, Lucas Fernando. January 2008 (has links)
Resumo: Introdução e Justificativa. No tratamento com implantes osseointegrados, o tecido ósseo peri-implantar sofre um processo de aposição e reabsorção, durante o primeiro ano após a restauração protética. Tem sido relatado que a platform switching reduz a remodelação óssea esperada, muito embora os mecanismos responsáveis por este processo não estejam claramente elucidados. Objetivo. O objetivo deste trabalho foi avaliar a distribuição de tensões no tecido ósseo peri-implantar, nos implantes e componente protéticos de coroa metalocerâmica implantossuportada, utilizando o conceito de platform switching e comparando-o com uma conexão regular abutment-implante, por meio do método de elementos finitos tridimensional (MEF-3D). Material e métodos. Dois modelos 3D reproduziram uma conexão regular entre abutment-implante com componentes de mesmo diâmetro (grupo Plataforma Regular - PR) e uma conexão com o conceito de platform switching (grupo Platform Switching - PS). Um implante regular (plataforma protética de 4.1mm) e um implante largo (plataforma protética de 5.0mm) foram utilizados para representar PR e PS, respectivamente, nos quais um componente protético regular de 4.1mm foi conectado para simular a coroa protética. Uma carga de 100N foi aplicada utilizando-se o programa ANSYS. Resultados. PS diminuiu a concentração de tensões no implante quando comparado com PR, alterando a distribuição das tensões na plataforma protética, o que resultou em diminuição das tensões no parafuso e tecido ósseo e aumento das tensões na coroa. Conclusões. Platform switching reduziu as tensões no tecido ósseo peri-implantar, o que pode resultar em uma diminuição da reabsorção óssea marginal. A utilização de componentes protéticos de menor diâmetro que a plataforma protética do implante diminuiu a concentração das tensões nos implantes e no parafuso, podendo ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Statement of problem. After implant insertion and loading, crestal bone usually undergoes remodeling and resorption during the first year following prosthetic restoration. It has been reported that the platform switching seems to reduce or eliminate the expected postrestoration crestal bone remodeling, although the mechanisms responsible for this process are not yet clearly drawn. Purpose. The objective of this study was to evaluate the stress distribution in periimplant bone tissue, implants and prosthetic components of single crown implantssupported with the use of platform switching concept, using three-dimensional Finite Element Analysis (3D- FEA). Material and methods. Two 3D finite element models reproduced a external hexagonal implant system with peri-implant bone tissue, in which a regular matching diameter connection of abutment-implant (Regular Platform group - RPG) and a platform switching connection (Platform Switching group - PSG) were simulated. A regular implant (prosthetic platform of 4.1mm) and a wide implant (prosthetic platform of 5.0mm) were used to represent the RPG and PSG, respectively, in which a regular prosthetic component of 4.1mm was connected to represent the crown. A load of 100N was applied on the models using ANSYS software. Results. PSG diminished the stress concentration at the implant when compared to RPG by altering the stress distribution at the prosthetic platform of the implant, which results in a decrease of stress into the screw and supporting bone and an increase of stress in the crown. Conclusions. Platform switching improved biomechanically the stress distribution in peri-implant bone tissue of implant system, which might result in a reduced marginal bone loss. The use of mismatching prosthetic components in relation to the implant prosthetic platform diameter seems to decrease stress concentration at implant and screw, which might represent less clinical complications. / Orientador: Wirley Gonçalves Assunção / Coorientador: Edson Antonio Capello Sousa / Banca: Eduardo Passos Rocha / Banca: Idelmo Rangel Garcia Júnior / Banca: Francisco de Assis Mollo Júnior / Banca: Emílio Barbosa e Silva / Doutor

Page generated in 0.1235 seconds