• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • Tagged with
  • 27
  • 27
  • 10
  • 8
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação de danos no material genético em anestesiologistas

Souza, Kátina Meneghetti de January 2016 (has links)
Orientador: Mariana Gobbo Braz / Resumo: A carência e a divergência de dados sobre o potencial genotóxico e mutagênico da exposição ocupacional aos anestésicos inalatórios mais modernos e mais utilizados atualmente estimularam a realização da presente pesquisa, que teve como objetivos avaliar os danos sistêmicos no DNA e os diferentes tipos celulares e biomarcadores de instabilidade genômica em células esfoliadas da mucosa oral em anestesiologistas. O estudo foi realizado em 60 médicos que atuavam no Hospital das Clínicas da Faculdade de Medicina de Botucatu – UNESP, os quais foram alocados em dois grupos: exposto, constituído por anestesiologistas expostos aos resíduos de gases anestésicos (isoflurano, sevoflurano, desflurano e óxido nitroso – N2O) e controle, constituído por médicos não expostos ocupacionalmente, os quais foram pareados por idade, sexo e estilo de vida com o grupo exposto. Amostras de sangue e de células esfoliadas orais foram coletadas de todos os participantes; os danos basais no DNA foram avaliados em linfócitos periféricos pelo teste do cometa e o teste do micronúcleo (MN) bucal foi utilizado para avaliação de diferentes parâmetros em células esfoliadas orais. As concentrações de N2O e dos halogenados foram mensuradas nas salas de operação com a utilização de espectrofotômetro infravermelho portátil. As concentrações médias de resíduos de gases anestésicos para todos os halogenados foi maior que 5 partes por milhão (ppm) e superior a 150 ppm para o N2O. Não houve diferença significativa entre ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Due to the lack and controversial data on the genotoxic and mutagenic potential of occupational exposure to the modern and most used inhaled anesthetics, the aim of the current study was to evaluate the systemic DNA damage, and the different cell types and genomic instability biomarkers in buccal exfoliated cells in anesthesiologists. The study was conducted in 60 physicians who worked in the Hospital of Botucatu Medical School - UNESP, and were allocated in two groups: the exposed group, consisted of anesthesiologists exposed to waste anesthetic gases (isoflurane, sevoflurane, desflurane and nitrous oxide - N2O) at least two years, and the control group consisted of non-exposed physicians, who were matched by age, sex and lifestyle with the exposed group. Venous blood and buccal exfoliated cells samples were collected from all participants; basal DNA damage was evaluated in peripheral lymphocytes by the comet assay, and the buccal micronucleus (MN) cytome (BMCyt) assay was used to evaluate different parameters in oral cells. The concentrations of N2O and halogenated anesthetics were measured in the operating rooms, by using of portable infrared spectrophotometer. The average concentrations of waste gases were greater than 5 parts per million (ppm) for all the halogenated anesthetics and more than 150 ppm for N2O. There was no significant difference between the groups in relation to DNA damage and there was no influence of the variables age, sex and time of exposure in the co... (Complete abstract click electronic access below) / Mestre
22

Avaliação da variação de pressão de pulso (VPP) frente a diferentes concentrações inaladas de isoflurano, desflurano e sevoflurano: modelo experimental em suínos / Evaluation of pulse pressure variation (PPV) using different concentrations of isoflurane, desflurane and sevoflurane: experimental model in pigs

Oshiro, Alexandre Hideaki 30 January 2013 (has links)
Introdução: Os anestésicos inalatórios empregados atualmente na prática clinica (isoflurano, sevoflurano e desflurano) possuem propriedades farmacocinéticas que favorecem rápida recuperação da anestesia, porém seu uso pode causar instabilidade hemodinâmica dose-dependente, relacionado à depressão direta da contratilidade miocárdica ou à hipovolemia relativa, derivado de um sequestro de sangue devido à vasodilatação do leito vascular periférico. Este estudo visa avaliar o comportamento da VPP durante a anestesia inalatória. Para tanto se utilizou três diferentes agentes inalatórios (isoflurano, sevoflurano e desflurano) em diferentes concentrações inaladas. Métodos: Foram utilizados 25 suínos divididos aleatoriamente em três grupos. Os animais foram submetidos à anestesia com o anestésico do respectivo grupo. Imediatamente após a determinação da CAM individual do agente inalatório em cada animal, ocorreu a primeira coleta de dados. O animal foi, então, exposto a diferentes níveis de CAM (1,0 CAM; 1,25 CAM) seguido por uma exposição decrescente de CAM (1,0 CAM); provocou-se então uma hemorragia correspondente a 30% da volemia e exposição a dois níveis de CAM (1,0 e 1,25), com 20 minutos em cada exposição. Ao final de cada período os valores ecocardiográficos e do VPP foram mensurados. A análise estatística foi realizada através de provas paramétricas empregando-se o método de comparações múltiplas para análise de variância com medidas repetidas (ANOVA). O grau de significância foi de 5% (p < 0,05). Resultados: Há aumento na variação de pressão de pulso com incremento de 25% na CAM dos anestésicos inalatórios (de 8±1 para 11±3% no grupo DESF, de 7±2 para 9±2 no grupo SEVO e de 9±4 para 10±3% no grupo ISO) sem diferença estatística entre os anestésicos. Apesar deste aumento na CAM e significativa hipotensão e queda no débito cardíaco, o aumento na VPP não torna o paciente responsivo a infusão de fluidos (o VPP permaneceu abaixo de 13%). Há pequena queda na PAM quando se eleva a CAM dos anestésicos em 25%, porém só há queda estatisticamente significativa no grupo DESF (de 84±7 para 68±12 mmHg). Não foram observadas alterações importantes em relação à contratilidade miocárdica. Conclusão: Observou-se que a VPP não é influenciada como o uso dos diferentes anestésicos inalatórios e apesar dos efeitos cardiovasculares esperados destes agentes, mantem-se a capacidade de demonstrar alterações de pré-carga mesmo em concentrações correspondentes a 1,25 CAM / Background: Inhalant anesthetics, such as isoflurane, sevoflurane and desflurane are widely used in daily clinical practice due to its pharmacological properties allowing a rapid recovery from anesthesia. Nevertheless, its use can lead to dose-dependent hemodynamic instability related to direct depression in myocardial contractility or to a relative hypovolemia caused by vasodilation of peripheral capillary bed. This study aims to evaluate the behavior of PPV during inhalant anesthesia. For this, three different anesthetics were used (isoflurane, sevoflurane and desflurane) with different inhaled concentrations. Methods: 25 young pigs were randomly assigned into three groups. Animals were anesthetized with its correspondent agent according to its group. After individual determination of minimal alveolar concentration (MAC), first data collection occurred. Pigs were then exposed to different MAC (1MAC and 1,25 MAC) followed by a decrease in MAC (1 MAC). At this point a 30% of estimated volemia hemorrhage was caused and pigs were exposed to a period of 1 MAC and after that 1,25 MAC. Each period lasted 20 minutes. At the end of each period, hemodynamic parameters and echocardiography were collected. Data were submitted to analysis of variance for repeated measures (ANOVA). P<0,05 was considered statistically significant. Results: There was an increase in PPV when with 1,25 MAC of all anesthetics. (from 8±1 to 11±3% in group DESF, from 7±2 to 9±2 in group SEVO and from 9±4 to 10±3% in group ISO), but without statistical difference among groups. Although there was an increase in PPV, followed by hypotension and drop in cardiac index, patients werent fluid responsive with a 25% increase in MAC, since PPV was lower than 13%. The decrease in blood pressure followed by 1,25MAC was only significant in DESF group (from 84±7 to 68±12 mmHg). No important alterations related to myocardial contractility were observed. Conclusion: PPV is not influenced by the use of different inhalant anesthetics and although there are cardiovascular effects of these agents which are expected, and were able to demonstrate alterations in preload even in concentration of 1,25 MAC
23

Avaliação da variação de pressão de pulso (VPP) frente a diferentes concentrações inaladas de isoflurano, desflurano e sevoflurano: modelo experimental em suínos / Evaluation of pulse pressure variation (PPV) using different concentrations of isoflurane, desflurane and sevoflurane: experimental model in pigs

Alexandre Hideaki Oshiro 30 January 2013 (has links)
Introdução: Os anestésicos inalatórios empregados atualmente na prática clinica (isoflurano, sevoflurano e desflurano) possuem propriedades farmacocinéticas que favorecem rápida recuperação da anestesia, porém seu uso pode causar instabilidade hemodinâmica dose-dependente, relacionado à depressão direta da contratilidade miocárdica ou à hipovolemia relativa, derivado de um sequestro de sangue devido à vasodilatação do leito vascular periférico. Este estudo visa avaliar o comportamento da VPP durante a anestesia inalatória. Para tanto se utilizou três diferentes agentes inalatórios (isoflurano, sevoflurano e desflurano) em diferentes concentrações inaladas. Métodos: Foram utilizados 25 suínos divididos aleatoriamente em três grupos. Os animais foram submetidos à anestesia com o anestésico do respectivo grupo. Imediatamente após a determinação da CAM individual do agente inalatório em cada animal, ocorreu a primeira coleta de dados. O animal foi, então, exposto a diferentes níveis de CAM (1,0 CAM; 1,25 CAM) seguido por uma exposição decrescente de CAM (1,0 CAM); provocou-se então uma hemorragia correspondente a 30% da volemia e exposição a dois níveis de CAM (1,0 e 1,25), com 20 minutos em cada exposição. Ao final de cada período os valores ecocardiográficos e do VPP foram mensurados. A análise estatística foi realizada através de provas paramétricas empregando-se o método de comparações múltiplas para análise de variância com medidas repetidas (ANOVA). O grau de significância foi de 5% (p < 0,05). Resultados: Há aumento na variação de pressão de pulso com incremento de 25% na CAM dos anestésicos inalatórios (de 8±1 para 11±3% no grupo DESF, de 7±2 para 9±2 no grupo SEVO e de 9±4 para 10±3% no grupo ISO) sem diferença estatística entre os anestésicos. Apesar deste aumento na CAM e significativa hipotensão e queda no débito cardíaco, o aumento na VPP não torna o paciente responsivo a infusão de fluidos (o VPP permaneceu abaixo de 13%). Há pequena queda na PAM quando se eleva a CAM dos anestésicos em 25%, porém só há queda estatisticamente significativa no grupo DESF (de 84±7 para 68±12 mmHg). Não foram observadas alterações importantes em relação à contratilidade miocárdica. Conclusão: Observou-se que a VPP não é influenciada como o uso dos diferentes anestésicos inalatórios e apesar dos efeitos cardiovasculares esperados destes agentes, mantem-se a capacidade de demonstrar alterações de pré-carga mesmo em concentrações correspondentes a 1,25 CAM / Background: Inhalant anesthetics, such as isoflurane, sevoflurane and desflurane are widely used in daily clinical practice due to its pharmacological properties allowing a rapid recovery from anesthesia. Nevertheless, its use can lead to dose-dependent hemodynamic instability related to direct depression in myocardial contractility or to a relative hypovolemia caused by vasodilation of peripheral capillary bed. This study aims to evaluate the behavior of PPV during inhalant anesthesia. For this, three different anesthetics were used (isoflurane, sevoflurane and desflurane) with different inhaled concentrations. Methods: 25 young pigs were randomly assigned into three groups. Animals were anesthetized with its correspondent agent according to its group. After individual determination of minimal alveolar concentration (MAC), first data collection occurred. Pigs were then exposed to different MAC (1MAC and 1,25 MAC) followed by a decrease in MAC (1 MAC). At this point a 30% of estimated volemia hemorrhage was caused and pigs were exposed to a period of 1 MAC and after that 1,25 MAC. Each period lasted 20 minutes. At the end of each period, hemodynamic parameters and echocardiography were collected. Data were submitted to analysis of variance for repeated measures (ANOVA). P<0,05 was considered statistically significant. Results: There was an increase in PPV when with 1,25 MAC of all anesthetics. (from 8±1 to 11±3% in group DESF, from 7±2 to 9±2 in group SEVO and from 9±4 to 10±3% in group ISO), but without statistical difference among groups. Although there was an increase in PPV, followed by hypotension and drop in cardiac index, patients werent fluid responsive with a 25% increase in MAC, since PPV was lower than 13%. The decrease in blood pressure followed by 1,25MAC was only significant in DESF group (from 84±7 to 68±12 mmHg). No important alterations related to myocardial contractility were observed. Conclusion: PPV is not influenced by the use of different inhalant anesthetics and although there are cardiovascular effects of these agents which are expected, and were able to demonstrate alterations in preload even in concentration of 1,25 MAC
24

Efeitos do sevoflurano administrado como pré-condicionante ou de modo contínuo nas lesões locais e sistêmicas da isquemia/reperfusão hepática. / Effects of sevoflurane preconditioning or continuously in local and systemic lesions of hepatic ischemia/reperfusion injury in the rat

Cavalcante, Fernanda Paula 28 January 2014 (has links)
INTRODUÇÃO: Lesões de isquemia/reperfusão hepáticas significativas podem ocorrer durante hepatectomias, no transplante hepático e no trauma hepático. A isquemia/reperfusão hepática pode levar à resposta inflamatória sistêmica associada a lesões locais e a distância. Estudos já demonstraram o efeito protetor do sevoflurano sobre as lesões de isquemia/reperfusão hepáticas; entretanto, nenhuma pesquisa, até o momento, estudou se esta proteção se dá por pré-condicionamento ou se depende da administração contínua do anestésico durante todo o período de isquemia/reperfusão. OBJETIVO: O objetivo deste estudo é avaliar o efeito do précondicionamento com sevoflurano ou da sua administração contínua nas lesões locais e sistêmicas da isquemia/reperfusão hepática em ratos. MÉTODOS: Os animais foram divididos em quatro grupos: grupo SHAM (n=12): animais submetidos à laparotomia mediana sem isquemia hepática; grupo Sem Tratamento (n=13): animais submetidos à isquemia/reperfusão hepática sem administração de sevoflurano; grupo Pré-condicionamento (n=13): sevoflurano foi administrado por 30 minutos e descontinuado antes da isquemia hepática; grupo Sevoflurano Contínuo (n=13): sevoflurano foi administrado por 30 minutos antes da isquemia hepática e também durante todo o período de isquemia/reperfusão. Nos três últimos grupos, ratos machos da linhagem wistar foram submetidos a modelo de isquemia hepática parcial por meio do clampeamento do pedículo hepático comum dos lobos mediano e anterolateral esquerdo. O clampe foi removido após 1 hora de isquemia e as análises realizadas após 4 horas de reperfusão. Em todos os grupos, a indução anestésica foi realizada com cetamina e xilazina, e os ratos foram intubados e submetidos à ventilação mecânica. O sangue foi coletado para dosagens de AST, ALT, TNF-alfa, IL-6 e IL-10. Os lobos hepáticos isquêmicos e não isquêmicos foram separados para estudo das funções oxidativas e fosforilativas mitocondriais, conteúdo de malondialdeído e análise histológica. Também foram avaliadas permeabilidade vascular pulmonar atividade da mieloperoxidase pulmonar. RESULTADOS: Após 4 horas de reperfusão, o grupo Sevoflurano Contínuo apresentou elevação dos níveis séricos de AST e ALT significativamente menor que os grupos Pré-condicionamento e Sem Tratamento (p < 0,05). No grupo Sevoflurano Contínuo, houve redução significativa da disfunção mitocondrial e incidência de necrose nos lobos hepáticos isquêmicos comparado aos grupos Pré-condicionamento e Sem Tratamento (p < 0,05). A permeabilidade vascular pulmonar foi menor no grupo Sevoflurano Contínuo comparado aos grupos Pré-condicionamento e Sem Tratamento (p < 0,05). Não foram encontradas diferenças no conteúdo de malondialdeído no tecido hepático, na atividade da mieloperoxidase pulmonar e nos níveis séricos de TNF-alfa, IL-6 e IL-10 entre os grupos. CONCLUSÃO: O pré-condicionamento com o sevoflurano não demonstrou proteção contra as lesões locais e sistêmicas da isquemia/reperfusão hepática. Entretanto, a administração contínua de sevoflurano reduziu ambas as lesões locais, no fígado isquêmico, e a distância, nos pulmões, associadas à isquemia/reperfusão hepática pulmonar foi menor no grupo Sevoflurano Contínuo comparado aos grupos Pré-condicionamento e Sem Tratamento (p < 0,05). Não foram encontradas diferenças no conteúdo de malondialdeído no tecido hepático, na atividade da mieloperoxidase pulmonar e nos níveis séricos de TNF-alfa, IL-6 e IL-10 entre os grupos. CONCLUSÃO: O pré-condicionamento com sevoflurano não demonstrou proteção contra as lesões locais e sistêmicas da isquemia/reperfusão hepática. Entretanto, a administração contínua de sevoflurano reduziu ambas as lesões locais, no fígado isquêmico, e a distância, nos pulmões, associadas à isquemia/reperfusão hepática / INTRODUCTION: Significant liver ischemia/reperfusion injury can occur during hepatectomies, liver transplantation, and liver trauma. Hepatic ischemia/reperfusion can trigger a systemic inflammatory syndrome associated with both local and systemic lesions. Previous studies have shown that sevoflurane protects from liver ischemia/reperfusion injury; however it was not studied yet if this protection is mediated by preconditioning or if it depends on continuous use of the anesthetic during the whole I/R injury period. AIM: It was hypothesized that sevoflurane preconditioning or continuously would protect from local and systemic lesions of liver ischemia/reperfusion injury in the rat. METHODS: Rats were divided into 4 groups: SHAM Group (n=12): animals were submitted to median laparotomy without liver ischemia; No Treatment Group (n=13): animals were submitted to I/R injury and no sevoflurane was used; Preconditioning Group (n=13): sevoflurane was used during 30 minutes and discontinued before liver ischemia; and Continuous Sevoflurane Group (n=13): sevoflurane was used 30 minutes before liver ischemia and during the whole liver I/R injury time. In the last three groups, wistar male rats underwent partial liver ischemia performed by clamping the hepatic pedicle from medium and left anterior lateral lobules. Clamp was removed after 1 hour of partial ischemia and analysis were performed after 4 hours of reperfusion. In all groups, anesthesia was induced with cetamine and xylazine and rats were intubated and mechanical ventilated. Blood was collected for determinations of AST, ALT, TNF-alfa, IL-6, and IL-10. Ischemic and non-ischemic liver tissues were assembled for mitochondrial oxidation and phosphorylation, malondialdehyde content, and histological analysis. Pulmonary vascular permeability and myeloperoxidase activity were also determined. RESULTS: Four hours after reperfusion Continuous Sevoflurane group had shown elevation of serum AST and ALT levels significantly lower than Preconditioning and No Treatment groups (p < 0.05). A significant reduction on liver mitochondrial dysfunction and liver necrosis incidence were observed in ischemic liver tissues in Continuous Sevoflurane group compared to Preconditioning and No Treatment groups (p < 0.05). A reduction on pulmonary vascular permeability was observed in Continuous Sevoflurane group compared to Preconditioning and No Treatment groups (p < 0.05). No differences in liver malondialdehyde content, pulmonary myeloperoxidase activity, and serum TNF-alfa, IL-6, and IL-10 levels were observed among these groups. CONCLUSIONS: Sevoflurane preconditioning did not show protection against local and systemic lesions associated with liver ischemia/reperfusion injury. On the other hand, continuous sevoflurane administration reduced both local lesions, in ischemic liver, and systemic lesions, in the lungs, associated with liver ischemia/reperfusion injury
25

Efeitos do sevoflurano administrado como pré-condicionante ou de modo contínuo nas lesões locais e sistêmicas da isquemia/reperfusão hepática. / Effects of sevoflurane preconditioning or continuously in local and systemic lesions of hepatic ischemia/reperfusion injury in the rat

Fernanda Paula Cavalcante 28 January 2014 (has links)
INTRODUÇÃO: Lesões de isquemia/reperfusão hepáticas significativas podem ocorrer durante hepatectomias, no transplante hepático e no trauma hepático. A isquemia/reperfusão hepática pode levar à resposta inflamatória sistêmica associada a lesões locais e a distância. Estudos já demonstraram o efeito protetor do sevoflurano sobre as lesões de isquemia/reperfusão hepáticas; entretanto, nenhuma pesquisa, até o momento, estudou se esta proteção se dá por pré-condicionamento ou se depende da administração contínua do anestésico durante todo o período de isquemia/reperfusão. OBJETIVO: O objetivo deste estudo é avaliar o efeito do précondicionamento com sevoflurano ou da sua administração contínua nas lesões locais e sistêmicas da isquemia/reperfusão hepática em ratos. MÉTODOS: Os animais foram divididos em quatro grupos: grupo SHAM (n=12): animais submetidos à laparotomia mediana sem isquemia hepática; grupo Sem Tratamento (n=13): animais submetidos à isquemia/reperfusão hepática sem administração de sevoflurano; grupo Pré-condicionamento (n=13): sevoflurano foi administrado por 30 minutos e descontinuado antes da isquemia hepática; grupo Sevoflurano Contínuo (n=13): sevoflurano foi administrado por 30 minutos antes da isquemia hepática e também durante todo o período de isquemia/reperfusão. Nos três últimos grupos, ratos machos da linhagem wistar foram submetidos a modelo de isquemia hepática parcial por meio do clampeamento do pedículo hepático comum dos lobos mediano e anterolateral esquerdo. O clampe foi removido após 1 hora de isquemia e as análises realizadas após 4 horas de reperfusão. Em todos os grupos, a indução anestésica foi realizada com cetamina e xilazina, e os ratos foram intubados e submetidos à ventilação mecânica. O sangue foi coletado para dosagens de AST, ALT, TNF-alfa, IL-6 e IL-10. Os lobos hepáticos isquêmicos e não isquêmicos foram separados para estudo das funções oxidativas e fosforilativas mitocondriais, conteúdo de malondialdeído e análise histológica. Também foram avaliadas permeabilidade vascular pulmonar atividade da mieloperoxidase pulmonar. RESULTADOS: Após 4 horas de reperfusão, o grupo Sevoflurano Contínuo apresentou elevação dos níveis séricos de AST e ALT significativamente menor que os grupos Pré-condicionamento e Sem Tratamento (p < 0,05). No grupo Sevoflurano Contínuo, houve redução significativa da disfunção mitocondrial e incidência de necrose nos lobos hepáticos isquêmicos comparado aos grupos Pré-condicionamento e Sem Tratamento (p < 0,05). A permeabilidade vascular pulmonar foi menor no grupo Sevoflurano Contínuo comparado aos grupos Pré-condicionamento e Sem Tratamento (p < 0,05). Não foram encontradas diferenças no conteúdo de malondialdeído no tecido hepático, na atividade da mieloperoxidase pulmonar e nos níveis séricos de TNF-alfa, IL-6 e IL-10 entre os grupos. CONCLUSÃO: O pré-condicionamento com o sevoflurano não demonstrou proteção contra as lesões locais e sistêmicas da isquemia/reperfusão hepática. Entretanto, a administração contínua de sevoflurano reduziu ambas as lesões locais, no fígado isquêmico, e a distância, nos pulmões, associadas à isquemia/reperfusão hepática pulmonar foi menor no grupo Sevoflurano Contínuo comparado aos grupos Pré-condicionamento e Sem Tratamento (p < 0,05). Não foram encontradas diferenças no conteúdo de malondialdeído no tecido hepático, na atividade da mieloperoxidase pulmonar e nos níveis séricos de TNF-alfa, IL-6 e IL-10 entre os grupos. CONCLUSÃO: O pré-condicionamento com sevoflurano não demonstrou proteção contra as lesões locais e sistêmicas da isquemia/reperfusão hepática. Entretanto, a administração contínua de sevoflurano reduziu ambas as lesões locais, no fígado isquêmico, e a distância, nos pulmões, associadas à isquemia/reperfusão hepática / INTRODUCTION: Significant liver ischemia/reperfusion injury can occur during hepatectomies, liver transplantation, and liver trauma. Hepatic ischemia/reperfusion can trigger a systemic inflammatory syndrome associated with both local and systemic lesions. Previous studies have shown that sevoflurane protects from liver ischemia/reperfusion injury; however it was not studied yet if this protection is mediated by preconditioning or if it depends on continuous use of the anesthetic during the whole I/R injury period. AIM: It was hypothesized that sevoflurane preconditioning or continuously would protect from local and systemic lesions of liver ischemia/reperfusion injury in the rat. METHODS: Rats were divided into 4 groups: SHAM Group (n=12): animals were submitted to median laparotomy without liver ischemia; No Treatment Group (n=13): animals were submitted to I/R injury and no sevoflurane was used; Preconditioning Group (n=13): sevoflurane was used during 30 minutes and discontinued before liver ischemia; and Continuous Sevoflurane Group (n=13): sevoflurane was used 30 minutes before liver ischemia and during the whole liver I/R injury time. In the last three groups, wistar male rats underwent partial liver ischemia performed by clamping the hepatic pedicle from medium and left anterior lateral lobules. Clamp was removed after 1 hour of partial ischemia and analysis were performed after 4 hours of reperfusion. In all groups, anesthesia was induced with cetamine and xylazine and rats were intubated and mechanical ventilated. Blood was collected for determinations of AST, ALT, TNF-alfa, IL-6, and IL-10. Ischemic and non-ischemic liver tissues were assembled for mitochondrial oxidation and phosphorylation, malondialdehyde content, and histological analysis. Pulmonary vascular permeability and myeloperoxidase activity were also determined. RESULTS: Four hours after reperfusion Continuous Sevoflurane group had shown elevation of serum AST and ALT levels significantly lower than Preconditioning and No Treatment groups (p < 0.05). A significant reduction on liver mitochondrial dysfunction and liver necrosis incidence were observed in ischemic liver tissues in Continuous Sevoflurane group compared to Preconditioning and No Treatment groups (p < 0.05). A reduction on pulmonary vascular permeability was observed in Continuous Sevoflurane group compared to Preconditioning and No Treatment groups (p < 0.05). No differences in liver malondialdehyde content, pulmonary myeloperoxidase activity, and serum TNF-alfa, IL-6, and IL-10 levels were observed among these groups. CONCLUSIONS: Sevoflurane preconditioning did not show protection against local and systemic lesions associated with liver ischemia/reperfusion injury. On the other hand, continuous sevoflurane administration reduced both local lesions, in ischemic liver, and systemic lesions, in the lungs, associated with liver ischemia/reperfusion injury
26

Efeito da umidificação dos gases anestésicos nas propriedades físicas e transportabilidade do muco respiratório durante anestesia geral / Effects of inspired gases humidity on respiratory mucus in patients under general anesthesia

Yagi, Claudia Simeire Albertini 09 October 2006 (has links)
Introdução: Em pacientes sob intubação endotraqueal os mecanismos fisiológicos de climatização do ar inspirado são anulados. Durante anestesia geral, quando os gases inspiratórios são ofertados secos e frios, a manutenção da umidade das vias aéreas é condição importante para prevenção de lesões da mucosa respiratória e ressecamento das secreções. Os sistemas de anestesia possuem propriedades de umidicação inerentes, decorrentes do sistema respiratório circular e a presença do absorvedor de CO2. Entretanto, os níveis de umidificação, durante a anestesia, dependem de vários fatores incluindo o tipo de ventilador anestésico, montagem do sistema respiratório e o fluxo de gás fresco utilizado. Porém não há dados na literatura que tenham investigado o efeito nos níveis de umidade do gás inspirado nas propriedades físicas e de transportabilidade do muco respiratório. Objetivo: Avaliar os níveis de Temperatura (T), umidade absoluta (UA) e umidade relativa (UR) do ar inspirado durante anestesia geral oferecidos pelo sistema circular valvular com absorção de CO2 e com a adição do HME em dois tipos de ventiladores (Dräger e Takaoka). Avaliar os efeitos do HME sobre os níveis de Temperatura e Umidade dos gases inspirados ofertados pelos dois equipamentos. Avaliar o impacto da umidade sobre as propriedades físicas e de transportabilidade do muco respiratório. Método: Foram selecionados 44 pacientes da Clínica Cirúrgica II do Departamento de Gastroenterologia do HCFMUSP com indicação de cirurgia abdominal eletiva e anestesia geral com duração superior a 4 horas. Os pacientes foram alocados em 4 grupos conforme o tipo do ventilador utilizado (Dräger ou Takaoka) e a presença ou ausência do HME. O muco respiratório e os dados de temperatura, UR e UA do gás ofertado foram coletados logo após a intubação endotraqueal, e a cada duas horas até o final da cirurgia. A análise do muco respiratório foi realizada através dos seguintes métodos: Transportabilidade mucociliar (MCT), em palato de rã; Transportabilidade pela tosse (TT), através da máquina simuladora da tosse e as propriedades de superfície, através do Ângulo de contato (AC). Resultado: O ventilador Dräger foi significantemente mais efetivo em ofertar níveis mais altos de T, UA e UR comparado ao ventilador Takaoka. A adição do HME aumentou a T e UA nos dois equipamentos. A UR aumentou somente no ventilador Takaoka. Houve um aumento do TMC e da TT no grupo que apresentou níveis mais altos de umidade (i.e. Dräger + HME). O AC não mostrou diferenças entre os quatro grupos. A análise longitudinal mostrou que o TMC foi positivamente afetado com o aumento da UA e UR. A TT foi positivamente afetada com a adição do HME. Conclusão: Nossos resultados mostram que o ventilador Dräger produziu níveis significantemente mais altos de umidade comparados ao ventilador Takaoka e que a adição do HME aumentou os níveis de umidade nos dois equipamentos estudados. Os equipamentos anestésicos e a adição do HME afetaram os níveis de umidade ofertados ao paciente durante a anestesia geral, e essas mudanças influenciaram a transportabilidade do muco respiratório / Background: In patients who are intubated, the natural mechanism of gas climatization by the nose and the upper airway is bypassed. During anesthesia, when the inspiratory gases are cold and dry, humidification of gases is recommended to prevent drying of the mucosal epithelium and respiratory secretions. The anesthesia systems have inherent humidifying properties as a result of the valvular rebreathing of some of the expired humidity and of the production of water in the CO2 absorber. However, the level of moisture in anesthetic ventilation is critically dependent on several factors that include the equipment, the arrangement of the circle breathing system and the fresh gas flow. To date the effect of humidity on respiratory mucus properties and transportability was not investigated. Objectives: The objective of this study was to measure the humidity and temperature of the inspired gas from a circle absorber system in two different ventilators (Dräger and Takaoka) and the effect of a heat and moisture exchanger (HME) on the inspired gas. Furthermore, we also evaluated the impact of humidity on in vitro mucus transportability and physical properties. Methods: We studied 44 patients with no pulmonary disease scheduled for elective surgery that were randomly allocated in four groups according to the anesthetic equipment (Dräger or Takaoka) and the absence or presence of HME. Respiratory mucus was collected and Temperature (T), absolute humidity (AH), relative humidity (RH) of inspired gases were recorded immediately after intubation (T0) and every 2 hours. In vitro respiratory mucus was studied by mucociliary transportability (MCT) by the frog palate method; cough clearance (CC) by the cough equipment, and contact angle (CA) by direct observation. Results: Dräger equipment delivered significantly higher levels of RH and AH when compared to Takaoka. The addition of HME increased AH and T in both equipments. RH was improved only in the Takaoka equipment. MCT, CC showed a non-significant trend to be higher in the group that provided the highest humidity (i.e Dräger + HME). CA did not change among groups. Longitudinal analysis showed that MCT was positively affected by an increase in AH and RH. CC was positively affected by the addition of HME. Conclusion: Our results showed that Dräger equipment was more effective in humidifying anesthetic gas than Takaoka. The performance of both equipments was improved when HME was added. The anesthetic equipment and the addition of HME affect the humidity delivered to the patient that in turn influences in vitro respiratory mucus transportability
27

Efeito da umidificação dos gases anestésicos nas propriedades físicas e transportabilidade do muco respiratório durante anestesia geral / Effects of inspired gases humidity on respiratory mucus in patients under general anesthesia

Claudia Simeire Albertini Yagi 09 October 2006 (has links)
Introdução: Em pacientes sob intubação endotraqueal os mecanismos fisiológicos de climatização do ar inspirado são anulados. Durante anestesia geral, quando os gases inspiratórios são ofertados secos e frios, a manutenção da umidade das vias aéreas é condição importante para prevenção de lesões da mucosa respiratória e ressecamento das secreções. Os sistemas de anestesia possuem propriedades de umidicação inerentes, decorrentes do sistema respiratório circular e a presença do absorvedor de CO2. Entretanto, os níveis de umidificação, durante a anestesia, dependem de vários fatores incluindo o tipo de ventilador anestésico, montagem do sistema respiratório e o fluxo de gás fresco utilizado. Porém não há dados na literatura que tenham investigado o efeito nos níveis de umidade do gás inspirado nas propriedades físicas e de transportabilidade do muco respiratório. Objetivo: Avaliar os níveis de Temperatura (T), umidade absoluta (UA) e umidade relativa (UR) do ar inspirado durante anestesia geral oferecidos pelo sistema circular valvular com absorção de CO2 e com a adição do HME em dois tipos de ventiladores (Dräger e Takaoka). Avaliar os efeitos do HME sobre os níveis de Temperatura e Umidade dos gases inspirados ofertados pelos dois equipamentos. Avaliar o impacto da umidade sobre as propriedades físicas e de transportabilidade do muco respiratório. Método: Foram selecionados 44 pacientes da Clínica Cirúrgica II do Departamento de Gastroenterologia do HCFMUSP com indicação de cirurgia abdominal eletiva e anestesia geral com duração superior a 4 horas. Os pacientes foram alocados em 4 grupos conforme o tipo do ventilador utilizado (Dräger ou Takaoka) e a presença ou ausência do HME. O muco respiratório e os dados de temperatura, UR e UA do gás ofertado foram coletados logo após a intubação endotraqueal, e a cada duas horas até o final da cirurgia. A análise do muco respiratório foi realizada através dos seguintes métodos: Transportabilidade mucociliar (MCT), em palato de rã; Transportabilidade pela tosse (TT), através da máquina simuladora da tosse e as propriedades de superfície, através do Ângulo de contato (AC). Resultado: O ventilador Dräger foi significantemente mais efetivo em ofertar níveis mais altos de T, UA e UR comparado ao ventilador Takaoka. A adição do HME aumentou a T e UA nos dois equipamentos. A UR aumentou somente no ventilador Takaoka. Houve um aumento do TMC e da TT no grupo que apresentou níveis mais altos de umidade (i.e. Dräger + HME). O AC não mostrou diferenças entre os quatro grupos. A análise longitudinal mostrou que o TMC foi positivamente afetado com o aumento da UA e UR. A TT foi positivamente afetada com a adição do HME. Conclusão: Nossos resultados mostram que o ventilador Dräger produziu níveis significantemente mais altos de umidade comparados ao ventilador Takaoka e que a adição do HME aumentou os níveis de umidade nos dois equipamentos estudados. Os equipamentos anestésicos e a adição do HME afetaram os níveis de umidade ofertados ao paciente durante a anestesia geral, e essas mudanças influenciaram a transportabilidade do muco respiratório / Background: In patients who are intubated, the natural mechanism of gas climatization by the nose and the upper airway is bypassed. During anesthesia, when the inspiratory gases are cold and dry, humidification of gases is recommended to prevent drying of the mucosal epithelium and respiratory secretions. The anesthesia systems have inherent humidifying properties as a result of the valvular rebreathing of some of the expired humidity and of the production of water in the CO2 absorber. However, the level of moisture in anesthetic ventilation is critically dependent on several factors that include the equipment, the arrangement of the circle breathing system and the fresh gas flow. To date the effect of humidity on respiratory mucus properties and transportability was not investigated. Objectives: The objective of this study was to measure the humidity and temperature of the inspired gas from a circle absorber system in two different ventilators (Dräger and Takaoka) and the effect of a heat and moisture exchanger (HME) on the inspired gas. Furthermore, we also evaluated the impact of humidity on in vitro mucus transportability and physical properties. Methods: We studied 44 patients with no pulmonary disease scheduled for elective surgery that were randomly allocated in four groups according to the anesthetic equipment (Dräger or Takaoka) and the absence or presence of HME. Respiratory mucus was collected and Temperature (T), absolute humidity (AH), relative humidity (RH) of inspired gases were recorded immediately after intubation (T0) and every 2 hours. In vitro respiratory mucus was studied by mucociliary transportability (MCT) by the frog palate method; cough clearance (CC) by the cough equipment, and contact angle (CA) by direct observation. Results: Dräger equipment delivered significantly higher levels of RH and AH when compared to Takaoka. The addition of HME increased AH and T in both equipments. RH was improved only in the Takaoka equipment. MCT, CC showed a non-significant trend to be higher in the group that provided the highest humidity (i.e Dräger + HME). CA did not change among groups. Longitudinal analysis showed that MCT was positively affected by an increase in AH and RH. CC was positively affected by the addition of HME. Conclusion: Our results showed that Dräger equipment was more effective in humidifying anesthetic gas than Takaoka. The performance of both equipments was improved when HME was added. The anesthetic equipment and the addition of HME affect the humidity delivered to the patient that in turn influences in vitro respiratory mucus transportability

Page generated in 0.3339 seconds