• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 184
  • 3
  • 1
  • Tagged with
  • 188
  • 188
  • 120
  • 118
  • 118
  • 118
  • 118
  • 118
  • 114
  • 109
  • 63
  • 44
  • 39
  • 34
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Diseño e implementación de un sistema antiséptico aplicado a la desinfección de habitaciones en hospitales mediante el uso del Ozono

Gonzales Vásquez, Carlos 22 July 2014 (has links)
Uno de los grandes problemas que ocurren en los centros de salud como hospitales, clínicas, etc. en el Perú son las enfermedades denominadas nosocomiales o conocidas como infecciones intrahospitarias. Para reducir el número de personas que adquieren estas enfermedades se cuenta con diversos mecanismos y normas que regulan el cuidado del paciente y personal de salud dentro de los hospitales. Existen muchos métodos para la desinfección de los ambientes en los hospitales, entre ellos los desinfectantes líquidos y la luz ultravioleta. El primero es el más común para la mayoría de ambientes dentro de los hospitales, sea emergencia, sala de operaciones, Unidad de Cuidados Intensivos (UCI), etc. El segundo método es menos utilizado en el Perú, dado principalmente por su alto costo. Una tercera opción, y poca explorada en nuestro país es el uso del ozono como desinfectante. Lo que plantea la presente tesis es el diseño e implementación de un sistema generador de ozono aplicado a la desinfección de habitaciones en los hospitales. El ozono debido a su alto potencial oxidante, es capaz de eliminar toda clase de bacteria, tanto en el aire como en alguna superficie. El nivel de desinfección dependerá de la concentración del ozono en un ambiente, el tipo de bacteria y el tiempo de exposición. El generador de ozono cuenta con una etapa de control con la lógica del programa y la interfaz de usuario; y una etapa de potencia para la obtención de los altos voltajes (superiores a 10 000V) conectados a un capacitador cilíndrico con una entrada de oxígeno gaseoso, el mismo que ingresará a una caja acrílica simulando un ambiente del hospital. Es ahí donde se realizará la exposición a 3 tipos de bacterias durante un tiempo determinado por la lógica de control. / Tesis
12

Diseño de un equipo para el análisis de los parámetros de la coagulación de la sangre usando el método de tromboelastografía rotativa

Vásquez Sotomayor, Flor del Milagro, Tejada Saavedra, Pablo Arturo 02 December 2011 (has links)
La sangre, el tejido de la vida, ha sido designada de esta manera porque refleja el balance de nuestro organismo en un equilibrio perfecto. Debido a sus múltiples funciones (transporte de oxígeno y nutrientes a las células, recolección de los productos de desecho, transporte de hormonas, intervención en el equilibrio de ácidos, sales, bases y agua en el interior de las células y en la regulación de la temperatura del cuerpo, defensa contra agentes externos y mecanismos de coagulación) representa una increíble fuente de información del estado biológico y químico del cuerpo y hasta la actualidad su análisis es una de las herramientas más importantes en la medicina. / Tesis
13

Propuesta de un sistema de gestión de mantenimiento de una clínica particular en la ciudad de Lima

García Urriaga, César Adolfo 04 April 2017 (has links)
En el presente trabajo se presenta una propuesta metodológica que contribuye con la optimización de los rendimientos económicos de una clínica particular a través del uso racional de sus activos tomando como herramienta un sistema de gestión de mantenimiento que ordene la misión del departamento de mantenimiento con el planeamiento estratégico de la organización. Para el desarrollo de la propuesta se ha utilizado como método el diseño de auditoría establecido en el “Radar de Mantenimiento” El modelo incorpora una propuesta de diseño y aplicación de un sistema de gestión de mantenimiento como herramienta metodológica de mejora continua que permite, por una parte, a partir de una auditoría, identificar fortalezas y debilidades de la gestión y replantear las metas y objetivos estratégicos. Por otra parte, establecer sobre la base del planeamiento estratégico, un plan anual de mantenimiento que permita alargar la vida útil de los activos y como consecuencia incrementar los márgenes de la clínica. En el sistema de gestión de mantenimiento propuesto se determinó la necesidad de desarrollar un plan de capacitación para el personal de mantenimiento en aspectos técnicos. Dado que el mantenimiento de equipos médicos, en su mayoría, es brindado por sus propios proveedores, así como la necesidad de generar estadísticas que sirvan de base para la toma de decisiones. En el desarrollo del sistema de gestión para el departamento de mantenimiento de la clínica se proponen las políticas del mantenimiento y planeamiento de la gestión, el manual de organización de funciones, las normas y procedimientos, el formato del presupuesto y los indicadores de control para medir el rendimiento. Asimismo se propone la metodología para determinar la criticidad de los equipos médicos e instalaciones de la clínica en estudio. Las proyecciones se desarrollan en un escenario aplicando el sistema de gestión de mantenimiento propuesto, dándole una política de mayor importancia e intensidad al mantenimiento preventivo desarrollado con el propósito de disminuir sensiblemente el alto gasto anual de mantenimiento cuyo principal componente es el mantenimiento reactivo. / Tesis
14

Desarrollo de un dispositivo de electroestimulación muscular para el entrenamiento y fortalecimiento de fibras musculares

Apéstegui Arriola, Aarón Marcial 27 June 2014 (has links)
El objetivo de este trabajo de tesis es el desarrollo de un dispositivo de electroestimulación muscular portátil, ligero y de bajo costo, que permita complementar el entrenamiento físico voluntario y tonifique las fibras musculares / Tesis
15

Planeamiento estratégico de la empresa Diagnóstica Peruana S.A.C

Peceros Quesada, Cesar Jesús, Vásquez Liñán, Hugo Juan, Meza Minaya, Doris Patricia, Arbildo Rabanal, Diana Katherine 28 September 2018 (has links)
En el presente documento se elabora el Planeamiento Estratégico de la empresa Diagnóstica Peruana. El plan estratégico es el resultado de un exhaustivo análisis de los factores externos e internos de la empresa, el cual permitió identificar las principales oportunidades, amenazas, fortalezas y debilidades que tiene la empresa en su sector. Asimismo, se elaboraron diferentes matrices en tres fases, a partir de las cuales se efectuó la decisión y elección de las estrategias principales, las cuales permitirán cumplir los objetivos de largo plazo y sus respectivos objetivos de corto plazo, con la finalidad de poder alcanzar la visión trazada en un horizonte de tiempo de 10 años. El sector salud en el Perú ha crecido de manera constante durante los últimos 10 años, y esto se debe a una mayor conciencia de la salud por parte de la población y esto a llevado a un incremento en los seguros particulares ya que el Estado no es capaz de cubrir las necesidades de toda la población. En líneas generales ha mostrado signos de mejora, una dinámica de cambio constante y mayor competitividad, lo cual la proyecta como un sector atractivo y en crecimiento. Las estrategias propuestas en el planeamiento estratégico se centran en aprovechar como insumo el valioso know-how del sector salud, permitiendo obtener un desarrollo sostenible de alto valor (i.e., personal calificado, infraestructura y equipamiento médico moderno, innovador y tecnológico) como ventaja competitiva y punto de diferenciación respecto de sus principales competidores (i.e., Productos Roche, Diagnóstico UAL). / In the present document, the Strategic Planning of the company “Diagnóstica Peruana” is elaborated. The strategic plan is the result of an exhaustive analysis of the external and internal factors of the company, which allowed to identify the main opportunities, threats, strengths and weaknesses of the company. Likewise, different matrices were elaborated in three phases, from which the decision and election of the main strategies were made, which will allow to fulfill the long-term objectives and their respective short-term objectives, with the purpose of being able to reach the vision traced in a time horizon of 10 years. The Peruvian health industry has grown steadily over the past 10 years, and this is due to a greater awareness of the population's health and an increase in the use of insurance. In general terms, it has shown signs of improvement, a dynamic of constant change and greater competitiveness, which projects it as an attractive industry. The strategies proposed in the strategic planning focus on taking advantage of the valuable know-how of the health industry as an input, allowing high-value sustainable development (i.e., qualified personnel, infrastructure and modern, innovative and technological medical equipment) competitive advantage and point of differentiation with respect to its main competitors (i.e., “Productos Roche”, “Diagnóstica UAL”). / Tesis
16

Diseño de un sistema de fototerapia utilizando LEDs aplicado en dermatología / Jesús Víctor Zegarra Flores

Zegarra Flores, Jesús Víctor 09 May 2011 (has links)
El objetivo general de esta tesis es presentar el diseño de un sistema de fototerapia que pueda servir como una alternativa de solución para los pacientes del área de dermatología de nuestro país y que de ese modo puedan tener una mejor calidad de atención. / Tesis
17

Sistema de medición y registro ambulatorio de presión arterial usando el método no invasivo oscilosmétrico

Piñeyro Fernández, José del Carmen Julián 09 May 2011 (has links)
El objetivo de este trabajo es diseñar un sistema de monitoreo, medición y registro de presión sanguínea ambulatorio. Este sistema estará conformado por una parte mecánica que generará la presión sobre la arteria braquial en el brazo; una parte electrónica que permitirá adquirir las presiones diastólica, sistólica y principal para mostrarlas en una pantalla y/o transferirlas a una computadora donde un programa de control permitirá configurar el equipo, transferir, procesar y presentar la información. / Tesis
18

Tralcán. Kit para aprender electrónica : kit educativo en madera para facilitar el aprendizaje de los conceptos básicos de la electrónica

Montero Capó, Pablo Esteban January 2016 (has links)
Memoria para optar al título de Diseñador Industrial
19

Efectividad de la Electrocinesis Manual en la disminucion del dolor por Cervicalgia Mecánica en el Centro Medico Naval Cirujano Mayor Santiago Távara

Rojas Chuco, Alicia Gavina January 2012 (has links)
El presente trabajo de investigación se desarrolló en el Centro Medico Naval Cirujano Mayor Santiago Távara” en el servicio de Medicina Física y Rehabilitación, en el periodo comprendido de enero a marzo 2012, con el objetivo de determinar la Efectividad de la Electrocinesis Manual en la disminución del dolor de la Cervicalgia Mecánica. Se realizó un estudio cuasi experimental, cuantitativo, prospectivo y comparativo. La muestra quedó comprendida con 40 pacientes divididos en dos grupos, 18 son varones y 22 son mujeres. Se construyó una tabla donde se evalúa la efectividad de la Electrocinesis Manual, dicha tabla se subdividió en 3 parámetros si en la última sesión el dolor disminuyó entre 100-70% el método es efectivo, si se encuentra entre 40-69% es regularmente efectivo y si se encuentra menos del 40% es no efectivo. El análisis de los datos se realizó en Excel y el análisis estadístico fue hecho en SPSS v 15. Dando como resultado en el grupo experimental, que el 90% de los participantes es efectivo y 10% es regularmente efectivo, en el grupo control, el 60% es regularmente efectivo y el 40% es no efectivo. Se concluyó que la Electrocinesis Manual constituye una técnica terapéutica efectiva con resultados positivos a corto tiempo, permitiendo al trabajador mantenerse laboralmente activo. PALABRAS CLAVES: Electrocinesis Manual, Terapia Combinada, TENS, Masaje, Frotación, Amasamiento, Effrurash.
20

Diseño e implementación de equipo regenerador de tejidos blandos basado en diodos emisores de luz y láser diodo

Romero Román, Herbert Ludwig, Manrique Solorzano, Susan Leslie 08 February 2013 (has links)
El objetivo del presente estudio es diseñar e implementar un equipo regenerador de tejidos blandos basado en diodos emisores de luz y diodo láser, con potencia luminosa regulable entre 5-100mW, en pasos de 5mW; con frecuencia de pulsación del haz de luz, generado por una onda cuadrada simétrica, variable entre 1-100Hz, en pasos de 1Hz; y tiempo de aplicación entre 1 y 15 minutos, con pasos de 1min; de esta de manera se puede controlar la energía luminosa total emitida por los diodos emisores de luz o diodo láser que contribuya en la investigación de una posible solución a la necesidad de acelerar el proceso regenerativo de los tejidos blandos. En la presente tesis se usará una longitud de onda entre 630 – 660nm, luz roja, debido a que en este rango de longitudes de onda se ha demostrado científicamente que se acelera el proceso de regeneración de las células. Se abarcan temas específicos como conocimientos teóricos y prácticos acerca del fundamento clínico de la regeneración celular. Para la implementación del equipo se hizo uso de un microcontrolador, que permitió controlar la energía luminosa emitida por los diodos emisores de luz y el láser diodo hacia los tejidos blandos, controlando la potencia, la frecuencia y el tiempo del tratamiento, además de ayudarnos a implementar un equipo interactivo con el usuario que permita su fácil uso, con una pantalla LCD y un teclado matricial. Se implementó el equipo siguiendo algunas consideraciones teóricas de la norma de seguridad eléctrica para equipos médicos, IEC60601 y la norma IEC 601-2-22, para equipos médicos eléctricos con requerimientos particulares para la seguridad del diagnóstico y terapia de equipos con láser. Se realizaron pruebas eléctricas y se verificó que el margen de error de 10% permitido por la norma no fuese superado. Las pruebas se realizaron a la corriente entregada para la potencia luminosa deseada, frecuencia y tiempo. Los resultados en potencia luminosa fueron: un error mínimo de 0.15% y máximo de 2.744% para los diodos emisores de luz, y un error mínimo de 2.338% y máximo de 8.371% para el diodo láser. Los resultados en frecuencia fueron: un error mínimo de 0.417% y máximo de 0.625%. Por último, el resultado en tiempo fue de un error del 0.01%. Se verifica que se cumplen las normas básicas para la implementación del equipo. Además se observa que el equipo deberá pasar muchas más pruebas para ser comercializado, ya que requiere experimentación clínica lo cual no es parte de esta tesis. Finalmente se realizó una tabulación del costo del proyecto. / Tesis

Page generated in 0.1018 seconds