• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 29
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 33
  • 33
  • 15
  • 12
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estimativa dos níveis de bioaerossóis e compostos orgânicos voláteis fúngicos em ambientes ocupacionais no município de Fortaleza - Ceará / Estimation of aerosols levels and volatile organic compounds fungal in occupational environments in the city of Fortaleza - Ceará

Pantoja, Lydia Dayanne Maia 20 May 2016 (has links)
PANTOJA, L. D. M. Estimativa dos níveis de bioaerossóis e compostos orgânicos voláteis fúngicos em ambientes ocupacionais no município de Fortaleza - Ceará. 2016. 169 f. Tese (Doutorado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2016-07-15T17:04:14Z No. of bitstreams: 1 2016_tese_ldmpantoja.pdf: 1775236 bytes, checksum: 8ce6e1787c0ed6b36d1e271f5b9d39e5 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-07-18T17:21:27Z (GMT) No. of bitstreams: 1 2016_tese_ldmpantoja.pdf: 1775236 bytes, checksum: 8ce6e1787c0ed6b36d1e271f5b9d39e5 (MD5) / Made available in DSpace on 2016-07-18T17:21:27Z (GMT). No. of bitstreams: 1 2016_tese_ldmpantoja.pdf: 1775236 bytes, checksum: 8ce6e1787c0ed6b36d1e271f5b9d39e5 (MD5) Previous issue date: 2016-05-20 / The search for more accurate methods of characterization of fungal composition in the air is required. It is known that when fungi develop within the structure of a building or ventilation filters, clearly there is a reasonable amount of \"hidden contamination\" can not be detected only through visual inspection. As well, the fact is that the fungi when they start to develop emit into the atmosphere Organic Compounds Fungal Volatile (COVFs), arising from the metabolic pathways or from degradation materials due to the release of enzymes produced by them. In the meantime, the goal of this thesis was to estimate the indoor air quality via bioaerosols and COVFs order improvements in monitoring and control of occupational environments in Fortaleza, Ceará. Therefore, there was the analysis of the researched environments (tertiary hospital, shopping center and public library) and application questionnaire to users in order to analyze the worker\'s understanding of the air quality. Then there was the preparation and validation of a protocol for determining COVFs. For the analysis of COVFs was used gas chromatography coupled to mass spectrometry is performed on Analysis Laboratory Trace - UFC. As for fungal samples were sent the Microbiology Laboratory - UECE, in order to identify through macro analysis and micromorphological and biochemical tests. 144 samples were analyzed front of COVFs, with nine compounds were detected in at least one of the sectors considered and only 3-octanone was not observed. In the quantitative analysis, with the highest COVFs concentrations (in g / m3) were 2-methyl-1-propanol, 3-methyl-1-butanol and 2-heptanone. At the regard to fungal findings, 72 samples were analyzed, being observed a high number of colony forming units per cubic meter (UFC.m-3) in all environments, in particular the general collection (3,497 UFC.m-3), followed by the center covered parking commercial (3245 UFC.m-3). While regarding the fungi spectrum composition airborne the three environments, it is formed predominantly by filamentous hyaline, especially the genus Aspergillus sp., and yeasts such as Candida species tropicalis. We evaluated the relationship between COVFs and fungal strains, and found the presence Six similarity groups such as 2-methyl-1-propanol which had a distribution space similar to fungi Acremonium sp., Aspergillus niger, Candida tropicalis and Penicillium sp. Also, we analyzed the distribution of the quantity of sample and COVFs Fungal by seasons, there was a significant difference between fungal samples and seasonality. The data presented mapped existence in the presence of COVFs working environments analyzed, characterizing the need for control of these compounds in ambient air indoor. Through research is expected to provide improved the current monitoring in the absence of national legislation on the COVFs, aiming in the future assist decision making managers in relation to occupational hazards, prompting further discussion in the academic and legislative environment and ultimately contribute to the systematic study of Aerobiology in the country. / A busca por métodos mais acurados de caracterização da composição fúngica no ar se faz necessária. Sabe-se que quando o fungo se desenvolve no interior da estrutura de um edifício ou em filtros de ventilação, claramente, há uma quantidade razoável de \"contaminação oculta\", não podendo ser detectada apenas através de uma inspeção visual. Bem como, é fato que os fungos quando começam a se desenvolver emitem para a atmosfera Compostos Orgânicos Voláteis Fúngicos (COVFs), que surgem das vias metabólicas ou a partir da degradação de materiais, devido à liberação de enzimas produzidas pelos mesmos. Nesse ínterim, o objetivo da presente tese foi estimar a qualidade do ar interno através de bioaerossóis e COVFs visando melhorias no monitoramento e controle de ambientes ocupacionais no município de Fortaleza, Ceará. Para tanto, houve a análise dos ambientes pesquisados (hospital terciário, shopping center e biblioteca pública) e aplicação de questionário aos usuários, visando analisar o entendimento do trabalhador sobre a qualidade do ar. Em seguida, houve a elaboração e validação de um protocolo para determinação de COVFs. Para a análise dos COVFs foi utilizada a cromatografia gasosa associada à espectrometria de massa, sendo executada no Laboratório de Análise Traço - UFC. Enquanto para as amostras fúngicas foram encaminhadas ao Laboratório de Microbiologia - UECE, visando à identificação por meio de análise macro e micromorfológica e provas bioquímicas. Foram analisadas 144 amostras frente aos COVFs, sendo que nove compostos foram detectados em pelo menos um dos setores analisados e apenas o 3-octanona não foi observado. Na análise quantitativa, os COVFs com as maiores concentrações (em μg/m3) foram 2-metil-1-propanol, 3-metil-1-butanol e 2-heptanona. No tocante aos achados fúngicos, 72 amostras foram analisadas, sendo observado um elevado número de unidades formadoras de colônia por metro cúbico (UFC.m-3) em todos os ambientes, em especial o acervo geral (3.497 UFC.m-3), seguido do estacionamento coberto do centro comercial (3.245 UFC.m-3). Enquanto a respeito da composição do espectro de fungos anemófilos dos três ambientes, este é formado predominantemente por filamentosos hialinos, com destaque para o gênero Aspergillus sp., bem como, leveduras, como a espécie Candida tropicalis. Avaliou-se a relação entre COVFs e amostras fúngicas, sendo constatado a presença de seis grupos de similaridade, como o 2-metil-1-propanol que apresentou uma distribuição espacial semelhante aos fungos Acremonium sp., Aspergillus niger, Candida tropicalis e Penicillium sp. Também, analisou-se a distribuição do quantitativo dos COVFs e das amostras fúngicas por estações climáticas, havendo diferença significativa entre amostras fúngicas e à sazonalidade. Os dados apresentados mapearam a existência da presença de COVFs nos ambientes laborais analisados, caracterizando assim a necessidade do controle desses compostos no ar ambiental de interiores. Com a pesquisa espera-se estabelecer uma melhoria no monitoramento vigente devido à ausência de legislação nacional em vigor sobre os COVFs, visando no futuro auxiliar a tomada de decisão de gestores em relação aos riscos ocupacionais, instigando uma maior discussão no meio acadêmico e legislativo e, por fim, contribuir para o estudo sistematizado da Aerobiologia no país.
2

Estudo do Fluxo de Deposição de Partículas para a Região Metropolitana da Grande Vitória usando dados de PTS

ALVES, M. R. 28 February 2011 (has links)
Made available in DSpace on 2018-08-24T22:53:14Z (GMT). No. of bitstreams: 1 tese_4953_.pdf: 5371703 bytes, checksum: a491d5faa9921bf55c5b5575a065c25a (MD5) Previous issue date: 2011-02-28 / A maior parte dos trabalhos científicos sobre a presença de material particulado na atmosfera está relacionada a partículas mais finas (menores que 2,5 μm ou menores que 10 μm), devido a seus efeitos sobre a saúde pulmonar dos seres humanos. Entretanto, partículas maiores podem causar consideráveis incômodos à população, devido a sua deposição sobre as superfícies, e a essas partículas, dá-se o nome de Material Particulado Depositado- MPD. A maior parte dos métodos experimentais para quantificação de partículas é bastante trabalhosa e onerosa, motivando o uso de métodos teóricos ou métodos indiretos de quantificação. O objetivo da aplicação da técnica indireta é reduzir o custo das medições e acelerar o tempo de obtenção dos dados. Nesse contexto, o objetivo geral deste trabalho é avaliar a hipótese da utilização de dados de Partículas Totais em Suspensão - PTS (medidos por equipamento automático) no cálculo do fluxo de deposição, substituindo o uso de medidores de deposição baseados em gravimetria. Dentro desse alvo, o presente trabalho buscou contribuir na implantação da rede de monitoramento de partículas sedimentáveis, bem como agilizar o processo de obtenção dos dados de fluxo de deposição dessas partículas. Os fluxos de deposição foram medidos no período de abril de 2009 a abril de 2010 em algumas das estações pertencentes à Rede Automática de Monitoramento da Qualidade do Ar (RAMQAR) pelo método de coleta baseado na Norma ASTM D1739 (1998). Esse mesmo fluxo foi estimado para uma das estações da rede (RAMQAR), a saber, Jardim Camburi, através de quatro modelos matemáticos. Três deles são baseados em modelos existentes na literatura e um é baseado no ajuste de curva para a obtenção da velocidade de deposição a partir dos dados experimentais de deposição. O último modelo apresentou resultados superiores aos demais. Tendo em vista o bom resultado desse último modelo, ele foi aplicado às demais estações. De forma geral, os resultados obtidos em todas as estações foram bons, conseguindo prever em 93% os valores de fluxo de deposição da região estudada. Demostrando ser uma ferramenta auxiliar para uma rápida estimativa dos fluxos de deposição onde as medições PTS estão disponíveis. No entanto, o modelo é dependente da existência de medidas de fluxo de deposição experimental para a sua calibração.
3

AVALIAÇÃO DE DESEMPENHO DO MODELO FOTOQUÍMICO CMAQ UTILIZANDO DIFERENTES CONDIÇÕES DE CONTORNO EM UMA REGIÃO URBANA E INDUSTRIALIZADA

PEDRUZZI, R. 13 April 2016 (has links)
Made available in DSpace on 2018-08-24T22:53:40Z (GMT). No. of bitstreams: 1 tese_9973_dissertacao-Rizzieri-Condicoes_Contorno_CMAQ_CORRECAO-rev-final.pdf: 10549247 bytes, checksum: eeb5475c2c5fe4865a8e58836416877c (MD5) Previous issue date: 2016-04-13 / O objetivo principal deste trabalho foi avaliar a influência das condições de contorno nas simulações com o modelo CMAQ sobre a Região Metropolitana da Grande Vitória (RMGV) para os poluentes, ozônio (O3) e material particulado inalável (MP10). Foram feitos quatro cenários de simulação para o mês de agosto de 2010 com diferentes condições de contorno. O primeiro cenário (M1) utilizando condições de contorno fixas, invariáveis com o tempo com concentrações nulas (zero) para todos os poluentes; um segundo cenário (M2) com valores fixos de concentração, invariável com o tempo com valores médios obtidos através do monitoramento das estações de qualidade da RMGV e de estações de Aracruz ao Norte e Anchieta ao sul; o terceiro cenário (M3) utilizou condições de contorno variáveis com o tempo provenientes de uma simulação prévia do CMAQ com um domínio maior, centralizado sobre a mesma área (RMGV); e por fim o quarto cenário (M4) que utilizou valores de concentrações variáveis com o tempo para as bordas oriundas de simulações com o modelo global GEOS-Chem. Todos os cenários utilizaram as mesmas condições de meteorológicas e emissões de poluentes, com condições meteorológicas geradas pelo modelo WRF versão 3.6.1 e emissões atmosféricas provenientes do inventário de emissões oficial da RMGV. As simulações de qualidade do ar foram feitas com domínio 61 x79 km centrado nas coordenadas -20,25ºS; -40,28ºW com resolução de 1 km, utilizando o CB05 e Aero6 e ainda o analisador de processos do CMAQ (PROCAN). Os resultados das simulações foram comparados com os dados medidos em estações de monitoramento da RMGV. Os resultados mostraram que para MP10 as condições de contorno não foram tão influentes nas concentrações simuladas, com pequenas variações das concentrações entre eles, porém, de um modo geral, os métodos M3 e M4 alcançaram os melhores resultados para estatística, entretanto o método M2 não está totalmente equivocado, porém deve-se ter cautela em usar esse método. Foram observados comportamentos diferentes entre as estações de monitoramento onde houve umas com valores superestimados em algumas horas e outras com valores subestimados, ocorrido provavelmente, por causa do tamanho da grade associado com as condições meteorológicas e variação temporal das emissões. Para o ozônio, notou-se que as condições de contorno influenciam diretamente nas concentrações modeladas, podendo inclusive influenciar no aumento da produção do O3 não apenas por reações químicas, mas também por processos de advecção e difusão atmosférica. Foi observado que cenário M1 faz com que as concentrações de O3 modeladas sejam bem pequenas, não representando a realidade. No cenário M2 as concentrações foram superestimadas, tanto nas estações quanto nas áreas próximas aos limites do domínio, principalmente na porção Oeste. Os cenários M3 e M4 alcançaram os melhores resultados de concentrações e estatística, sendo estes os mais aconselháveis quando o objetivo é avaliar o ozônio. Como o domínio final utilizado na modelagem do CMAQ foi de apenas 61 x 79km, observou-se que as condições de fronteira influenciam diretamente em toda grade do domínio, principalmente para ozônio, ao utilizar o processador de analises (PROCAN). Quando as concentrações de contorno são altas, independentes de serem fixas ou variantes com o tempo, os processos de advecção e difusão turbulenta promovem um incremento muito maior nas regiões de fronteira com a RMGV, aumentando a concentração.
4

Estudo do transporte atmosférico de Mp10 e SO2 com os Modelos WRF/CMAQ em regiões costeiras urbanas

Loriato, Ayres Geraldo 29 June 2015 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2016-02-24T21:09:58Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese_Ayres.pdf: 15719153 bytes, checksum: 53b0372c0a809dfc80c8f40fdd30735d (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2016-03-09T16:00:59Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese_Ayres.pdf: 15719153 bytes, checksum: 53b0372c0a809dfc80c8f40fdd30735d (MD5) / Made available in DSpace on 2016-03-09T16:00:59Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese_Ayres.pdf: 15719153 bytes, checksum: 53b0372c0a809dfc80c8f40fdd30735d (MD5) Previous issue date: 2015 / CAPES / O objetivo principal deste trabalho foi o estudo do transporte atmosférico de PM10 e SO2 em regiões costeiras urbanas usando modelos WRF/CMAQ. Duas regiões foram contempladas neste estudo. Uma é a Região da Grande Vitória (RGV), no estado do Espírito Santo, Brasil; a outra é a Região da Grande Dunkerque (RGD), no Departamento Nord Pas-de-Calais, França. A RGV é cercada por uma cadeia de montanhas paralela à costa, resultando num topografia complexa e acidentada. Já a RGD possui uma topografia muito mais suave. As entradas de dados para os modelos WRF/CMAQ englobaram o inventário de emissões de poluentes atmosféricos do IEMA-ES para a RGV, e o inventário de emissões no nível do solo de Nord Pas-de-Calais denominado ―Cadastre_totaux_3km_A2008 _M2010_V2_SNAPN2‖ para a RGD. Ambos os inventários apresentaram restrições, todavia. O inventário da RGV apresentou valores de ressuspensão em vias de tráfego elevados, em comparação com diversos estudos, e teve esses dados modificados. Os dados no nível do solo e a grande área de das células da grade (9 km2) do inventário da RGD não permitiram resultados satisfatórios de modelagem. A validação dos modelos foi realizada por comparação com resultados obtidos em duas campanhas experimentais: uma na cidade de Dunkerque, no norte da França, em setembro de 2009; a outra na cidade de Vitória, no sudeste do Brasil, em julho de 2012. Esses dados foram obtidos pelo uso de sistemas de Light Detection and Ranging (LIDAR) e Sonic Detection and Ranging (SODAR), bem como de Estações Meteorológicas de Superfície (EMS) e de monitoramento atmosférico. Os resultados deste trabalho mostraram que: a) existe uma necessidade de melhorias contínuas nos inventários regionais de emissões, adaptando-os para condições locais específicas e focando na obtenção de parâmetros necessários para modelagem fotoquímica; b) os valores de módulo e direção das velocidades obtidas na modelagem meteorológica influenciam fortemente os resultados da modelagem de concentração de poluentes; c) a qualidade do ar tanto na RGV quanto na RGD merece atenção, sobretudo no que diz respeito às concentrações de MP10. De acordo com os dados das estações de monitoramento, a situação parece mais crítica na RGD; d) a modelagem da RGV apresentou resultados mais satisfatórios do que a da RGD, de acordo com os resultados das validações; e) a entrada da brisa do mar provocou alterações significativas na concentração dos poluentes, o que pôde ser observado na análise da dinâmica da dispersão de MP10 e SO2. Esse fenômeno foi mais marcante na RGV, onde a entrada da brisa marítima provocou um movimento oscilatório na pluma de poluição, levando-a para os bairros mais densamente povoados do conglomerado urbano. Na RGD, a entrada da brisa não foi cotidiana e, no dia em que ela aconteceu, houve uma alteração de quase 180º na direção do movimento da pluma de poluição. Além do aumento da turbulência vertical, o qual já foi estudado por diversos autores, este estudo focou também na influência brisa do mar na dinâmica da pluma de dispersão de poluentes atmosféricos em regiões costeiras. / This work's main objective is to study atmospheric transportation of MP10 and SO2 in urban coastal areas using WRF/CMAQ modeling. Two main areas were chosen for this purpose. One is Great Vitória Area (GVA), in Espírito Santo State, Brasil; the other is Great Dunkerque Area (GDA), in Nord Pas-de-Calais, France. GVA is surrounded by a mountain range parallel to the coast, which makes its topography complex and rugged. On the other hand, GDA's topography is much smoother. Modeling inputs encompassed IEMA-ES' inventory of atmospheric pollutants emissions for GVA, and Nord Pas-de-Calais' inventory of ground level emissions named " Cadastre_totaux_3km_A2008 _M2010_V2_SNAPN2" for GDA. Both inventories showed restrictions, however. GVA's showed high traffic lanes resuspension in comparison with several studies, so those data were altered. Ground level data and large grid area (9 km2) of GDA inventory didn't allow for satisfying modeling results. Modeled results were validated by comparing them with two experimental campaigns: one performed in the city of Dunkerque, North of France, on September 2009; the other in Vitória, Southeast of Brazil, on July 2012. Experimental data were obtained through the use of Light Detection and Ranging (LIDAR), Sonic Detection and Ranging (SODAR), Surface Meteorological Stations (SMS) and atmospheric monitoring stations. Results of this work showed that: a) there is a need for continuous improvement on regional inventories of emissions, adapting them to specific local characteristics and focusing on obtaining parameters required for photochemical modeling; b) the direction and magnitude of velocity vectors obtained from meteorological modeling have a high impact on pollutant concentrations modeling; c) air quality in both GVA and GDA deserve attention, especially regarding MP10 concentrations. Based on monitoring stations data, the situation seems more critical in GDA; d) modeling in GVA was better than in GDA according to validation results; e) sea breeze inflow caused significant alteration on pollutants concentration, which was observed analyzing MP10 and SO2 dispersion dynamics. This phenomenon was more distinctive in GVA, where the sea breeze caused an oscillatory motion on the pollution plume, moving it to the urban agglomeration most densely populated neighborhoods. In GDA, sea breeze inflow wasn`t a daily phenomenon, and on the day when it occurred there was a change of almost 180º in the pollution plume direction of movement. In addition to vertical turbulence increase, which has already been studied by many authors, this study also focus on influence of sea-breeze of plume dynamics effects on dispersing atmospheric pollutants in coastal areas.
5

Desempenho da qualidade do ar em estudos de caso de ambientes hospitalares no contexto climático de Brasília – DF

Aguiar, João Renato Carneiro de 15 September 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismo, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-12-13T19:13:41Z No. of bitstreams: 1 2017_JoãoRenatoCarneirodeAguiar.pdf: 9426890 bytes, checksum: 54a5a7b556bd833299a84edfd6f99c45 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-02-20T20:48:38Z (GMT) No. of bitstreams: 1 2017_JoãoRenatoCarneirodeAguiar.pdf: 9426890 bytes, checksum: 54a5a7b556bd833299a84edfd6f99c45 (MD5) / Made available in DSpace on 2018-02-20T20:48:38Z (GMT). No. of bitstreams: 1 2017_JoãoRenatoCarneirodeAguiar.pdf: 9426890 bytes, checksum: 54a5a7b556bd833299a84edfd6f99c45 (MD5) Previous issue date: 2018-02-20 / Estudos demonstram os efeitos negativos das altas concentrações de partículas indesejadas no ar para a saúde humana. Normas vigentes da área de saúde preconizam a utilização de equipamentos artificiais para manter a qualidade do ar interno nos ambientes hospitalares, em detrimento de soluções passivas de ventilação. Neste sentido, a presente dissertação aborda o tema da ventilação natural em ambientes de saúde, com o objetivo principal de avaliar a renovação do ar em ambientes hospitalares no contexto climático de Brasília por meio de simulações computacionais. Como estudos de caso foram estudados 5 ambientes hospitalares de Brasília: o Hospital de Base do Distrito Federal, Hospital da Criança de Brasília, Hospital Sarah Centro, Hospital Sarah Lago e Hospital de Apoio de Brasília. A pesquisa se estruturou a partir da revisão bibliográfica com o uso das normas e legislações específicas; coleta de informações referente aos estudos de caso escolhidos; métodos para a definição da velocidade dos ventos predominantes e, por fim, a realização da simulação pelo processo computacional CFD (Computacional Fluid Dynamics – CFD Autodesk 2015) para analisar o potencial da ventilação natural nos ambientes hospitalares estudados. Os parâmetros para definição da velocidade do vento foram fornecidos pelas normais climatológicas (INMET), pela ficha bioclimática e pela fórmula matemática que avalia condicionantes do terreno e altura das aberturas. Os resultados da pesquisa apontam que o uso da ventilação natural nos ambientes é eficaz na maioria dos casos, sobretudo quando são associados a boa qualidade do ar externo e uma boa análise das condicionantes do entorno (que envolve direção dos ventos predominantes e análise de barreiras urbanas), assim sendo suficiente para promover uma boa qualidade do ar interna. / Studies demonstrate the negative effects of high concentrations of unwanted particles in the air for the human health. Currents health standards recommend the use of artificial equipment to maintain indoor air quality in hospital environments, in detriment of passive ventilations solutions. In this sense, the present dissertation aims to disseminate the topic of natural ventilation in health environments, with the main objective of evaluating the air renewal in the hospitals in the climatic context of Brasília by means of computational simulations. The case studies were 5 hospitals environments in Brasília: The Hospital de Base do Distrito Federal, Hospital da Criança de Brasília, Hospital Sarah Centro, Hospital Sarah Lago and Hospital de Apoio de Brasília. The research was structured from the bibliographical review with the use of specific norms and legislation, collection of information regarding the selected case studies, methods for definition of prevailing wind velocity and, finally a simulation performance for the CFD (Computational Fluid Dynamics – CFD Autodesk 2015) process to analyze the potential of natural ventilation in the hospitals studied. The parameters for definition the wind speed is provided by normal climatological (INMET), by bioclimatic chart and by mathematical formula that evaluates terrain conditions and height of the openings. The results of the research indicated that the use of natural ventilation in the health environments is effective in the most cases, especially when good external air quality is associated with a good analysis of the environmental conditions factors (involving predominant winds directions and analysis of urbans barriers), thus being sufficient to promote a good indoor air quality.
6

Diagrama de ventilação natural : ferramenta de análise do potencial da ventilação natural no estudo preliminar de projeto

Sales, Gustavo de Luna 11 March 2016 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, 2016. / Submitted by Camila Duarte (camiladias@bce.unb.br) on 2016-07-20T16:28:11Z No. of bitstreams: 1 2016_GustavodeLunaSales.pdf: 6698120 bytes, checksum: 0e96c1b5bde43be2b8976e3584d413ad (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-02-23T14:50:54Z (GMT) No. of bitstreams: 1 2016_GustavodeLunaSales.pdf: 6698120 bytes, checksum: 0e96c1b5bde43be2b8976e3584d413ad (MD5) / Made available in DSpace on 2017-02-23T14:50:54Z (GMT). No. of bitstreams: 1 2016_GustavodeLunaSales.pdf: 6698120 bytes, checksum: 0e96c1b5bde43be2b8976e3584d413ad (MD5) / A presente tese aborda o desenvolvimento do Diagrama de Ventilação Natural (DVN) – ferramenta de análise do potencial da ventilação natural, para favorecer a Qualidade Interna do Ar (QIA) e o Conforto Térmico Passivo (CTP) em projetos de habitações. Parte-se da hipótese de que é possível desenvolver uma ferramenta que proporcione uma análise mais simples, amigável e rápida em comparação com as atuais ferramentas disponíveis, e que seja aplicável durante as primeiras etapas do processo de projetação – mais especificamente, na etapa do Estudo Preliminar (EP). Para tanto, foram levantados na bibliografia sobre o tema os principais fatores externos e internos ao projeto que influenciam o potencial da ventilação natural em termos de QIA e o CTP. Posteriormente foram levantados os parâmetros legais mínimos exigidos pelos Códigos de Edificações e Normas Técnicas referentes à ventilação natural que, juntamente com os fatores externos e internos de projeto, foram transformados em variáveis a serem analisadas pelo DVN. Por fim, foram analisados os principais modelos que atualmente estão disponíveis para a análise da ventilação natural no projeto de arquitetura – modelos analíticos e empíricos, modelos em escala, modelo multizona e de zona, modelos computacionais de dinâmica dos fluidos. Essa análise identificou as principais deficiências das ferramentas/modelos atuais em termos de aplicação durante a etapa de Estudo Preliminar de Projeto – sendo essas: custo de aplicação, nível de habilidade técnica exigido do usuário, e interface pouco amigável. Assim, para suprir as deficiências apontadas, foi identificado que a ferramenta a ser desenvolvida deveria ser fundamentada nos princípios dos modelos gráficos – que visam justamente à simplificação do problema a ser estudado, a análise das principais variáveis influentes e a obtenção de um diagnóstico/resultado estimado por meio da combinação das variáveis identificadas. Após a estruturação do DVN, foi desenvolvida a ferramenta com linguagem simples, amigável e acessível gratuitamente na rede mundial de computadores. O DVN possibilita a quantificação do potencial da ventilação natural em favorecer a QIA e o CTP, fornece o número de renovações de ar por hora estimado para os ambientes de quarto, sala, cozinha e banheiro, além de informar ao usuário quais os aspectos que o EP cumpre em termos normativos/legais e quais as diretrizes para a melhoria de possíveis problemas. / This thesis describes the development of Natural Ventilation Diagram (NVD) - an analysis tool of the potential of natural ventilation to provide the Indoor Air Quality and Passive Thermal Comfort in the design of residential buildings. It starts with the hypothesis that it is possible develop a tool that provides more simple, user friendly, and faster analysis in comparison with the current available tools - and that is applicable during the first stages of the design process. Have been raised in the literature the major internal and external factors that influence the potential of natural ventilation associated with IAQ and PTC. Afterwards have been identified the minimum legal standards required by the Building Codes and Technical Standards relating to natural ventilation. The legal parameters and external and internal factors were transformed into variables that the user can analyze by the NVD. Finally, were analyzed the main models that are currently available for the analysis of natural ventilation in architectural design – empirical and analytical models, scale models, multizonal and zonal models, computacional computational fluid dynamics models. This analysis identified the main weaknesses of the tools / current models in terms of application for the Preliminary Design stage process - related to the cost of implementation, technical skill level required of the user, and unfriendly interface. Therefore, to fulfill the identified deficiencies, it was identified that the tool to be developed should be based on the principles of graphical models. The graphics models aim at simplification of the problem to be studied, the analysis of main influential variables and obtaining a diagnostic/result estimated by the combination of the identified variables. After structuring of NVD, it was developed the tool with simple language, friendly and available free on the World Wide Web. The NVD enable quantification of natural ventilation potential, provides an estimation of the number of air change per hour for rooms, living room, kitchen and bathroom. As well as inform the user which aspects meets in regulatory / legal terms and what the guidelines for the improvement of potential problems. / En esta tesis se describe el desarrollo del Diagrama de Ventilación Natural (DVN) - una herramienta de análisis del potencial de ventilación natural para promover la Calidad del Aire Interior (CAI) y el Confort Térmico Pasivo (CTP) en proyectos de viviendas. La posibilidad de desarrollar una herramienta que proporciona un análisis simple de usar y rápido de usuario, en comparación con las herramientas actuales disponibles, y que es aplicable durante las primeras etapas del proceso de projetação es la hipótesis inicial. En un primer momento ha planteado en la literatura sobre el tema de los principales factores externos e internos que influyen en la ventilación potencial del proyecto. Después de los estándares legales mínimos aumentaron requeridos por los códigos de construcción y normas técnicas relativas a la ventilación natural. Todos estos parámetros planteados fueron transformadas en variables para ser analizados por la herramienta propuesta. Por último, los principales modelos que están actualmente disponibles se analizaron para el análisis de la ventilación natural en el diseño arquitectónico - modelos analíticos y empíricos, modelos a escala, multi-zona y el modelo de zona, los modelos informáticos de dinámica de fluidos. Este análisis identifica las principales deficiencias de las / los modelos actuales herramientas en términos de aplicación durante la etapa de diseño preliminar del estudio - a saber: el costo de aplicación, nivel de habilidad técnica requerida del usuario, y la interfaz poco amigable. Para satisfacer las deficiencias identificadas, se identificó que la herramienta que se desarrollen deben estar basadas en los principios de los modelos gráficos. Después de estructuración de lo DVN, se desarrolló la herramienta con un lenguaje sencillo, amable y disponible gratuitamente en la World Wide Web. Lo que permite la cuantificación de la potencial de la ventilación natural en la calidad del aire favor y confort térmico; proporciona el número de renovaciones de aire por hora para la sala de estar, cocina y baño, así como informar al usuario qué aspectos se reúne en términos normativos / legales y cuáles son las pautas para la mejora de los problemas potenciales.
7

Superfícies em madeira e qualidade do ar

Silva, Bárbara Alpendre da 21 December 2012 (has links)
Resumo: Devido aos conhecidos impactos ambientais provocados pela indústria da construção civil, a busca pela sustentabilidade tem motivado o uso de materiais naturais e com impacto ambiental reduzido. Neste sentido, a madeira e os produtos derivados são alternativas coerentes com as práticas do desenvolvimento sustentável e se tornaram opções de materiais consagrados para uso na arquitetura, tanto pelo apelo de sustentabilidade quanto pela percepção e aceitação do material por parte do usuário. No entanto, o uso de tais materiais está associado ao uso de preservativos químicos e produtos para tratamento e acabamento de superfícies, os quais, quando utilizados em ambientes internos, representam uma ameaça à qualidade do ar e à salubridade. Destaca-se, portanto, o papel dos profissionais especificadores na busca de soluções práticas para os possíveis riscos que tais produtos apresentam à saúde humana. Foi realizada uma pesquisa bibliográfica a fim de oferecer atualização sobre os diferentes produtos associados ao uso da madeira no ambiente construído, considerando sua influência na qualidade do ar interior, impactos à saúde e restrições e cuidados durante o uso, e posteriormente, uma pesquisa de opinião com os profissionais da área no estado do Paraná, a fim de verificar o conhecimento destes sobre o assunto pesquisado. Todos os produtos pesquisados apresentaram alguma influência na salubridade dos ambientes, evidenciando-se a relevância da criação de espaços bem ventilados, com taxas adequadas de renovação do ar. Na pesquisa com os profissionais, observou-se que seu conhecimento ainda é insatisfatório, não havendo coerência entra suas práticas e afirmações. Além disso, a grande maioria mostra não ter conhecimento dos riscos relacionados ao uso dos produtos pesquisados e à reutilização da madeira tratada, comprovando-se a necessidade de elaboração de mais pesquisas e maior divulgação do assunto, contribuindo dessa forma com especificações conscientes para a concepção de ambientes saudáveis e mais sustentáveis.
8

Quantificação, espacialização e especiação das emissões atmosféricas de origem veicular na região metropolitana da Grande Vitória

ARAUJO, I. B. 08 July 2016 (has links)
Made available in DSpace on 2018-08-01T23:57:59Z (GMT). No. of bitstreams: 1 tese_10586_Dissert_Igor_Baptista.pdf: 1982700 bytes, checksum: 059e30cb1da7fdb9ab0d68f0e524f2c6 (MD5) Previous issue date: 2016-07-08 / O objetivo principal deste trabalho foi investigar as emissões atmosféricas de origem veicular na Região Metropolitana da Grande Vitória (RMGV), no estado do Espírito Santo, e disponibilizar as mesmas em um sistema que as caracterize quantitativamente no tempo e no espaço, bem como represente sua natureza química (especiação química) nesses dois campos. Foram recalculadas as taxas de emissões veiculares utilizando metodologia de estimativa atualizada e oficial do Brasil, disponibilizada pelo Ministério do Meio Ambiente, identificando as mudanças obtidas no inventário, frente ao inventário oficial existente. Dentro do ambiente do modelo Sparse Matrix Operator Kernel Emissions SMOKE foi realizada a especiação química de todas as fontes inventariadas, além da simulação da evolução espacial e temporal das emissões dos poluentes da RMGV, com base no inventário de fontes atualizado. Os resultados demonstraram que os veículos pesados (caminhões e ônibus) somam apenas 7% da frota, mas são responsáveis por 56%, 40% e 63% das emissões de NOX, SO2 e MP respectivamente, além do predomínio pela resuspensão veicular (48,2%) e desgaste de freios e pneus (32,7%) para MP, enquanto que MP10 e MP2,5 tem suas maiores contribuições associadas às emissões por desgaste de freios e pneus e escapamento. Esses resultados foram comparados com os dados do inventário oficial disponibilizado pelo órgão ambiental local (IEMA), onde a taxa anual das emissões calculadas para os veículos nesta pesquisa foi até 10 vezes menor (MP10) que a estimada no inventário capitaneado pelo IEMA, afetando também qualitativamente a distribuição da participação das fontes emissoras não veiculares na RMGV.
9

Qualidade do ar na area de influencia do polo industrial de Paulinia-SP : 2000-2002

Tresmondi, Ana Claudia Camargo de Lima 03 August 2018 (has links)
Orientador: Edson Tomaz / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-03T18:15:48Z (GMT). No. of bitstreams: 1 Tresmondi_AnaClaudiaCamargodeLima_D.pdf: 7453145 bytes, checksum: 2dfa466ee8d86b4ff70c49ae8353f52c (MD5) Previous issue date: 2003 / Doutorado
10

Qualidade do ar interior e condições arquitetônico-construtivas em ambientes de permanência dos animais em biotérios-estudos de casos / Indoor air quality and architectural-constructive conditions in environment of stay of animals in animal houses - Case studies

Barros, Gabriele de Almeida 26 July 2012 (has links)
Submitted by Amauri Alves (amauri.alves@ufv.br) on 2015-11-09T17:04:20Z No. of bitstreams: 1 texto completo.pdf: 2750534 bytes, checksum: 04868fe839d6a75af6ce8c9c9a13d617 (MD5) / Made available in DSpace on 2015-11-09T17:04:20Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2750534 bytes, checksum: 04868fe839d6a75af6ce8c9c9a13d617 (MD5) Previous issue date: 2012-07-26 / A presente pesquisa buscou investigar e inter-relacionar condições arquitetônico-construtivas e de qualidade do ar interior em ambientes de permanência dos animais em biotérios de uma Instituição Pública de Ensino Superior - IPES, uma vez que são ambientes fechados, de pouco ventilação e que necessitam de máximo controle ambiental devido as especificidades das suas atividades criação e manutenção de espécies utilizadas em experimentos para atender programas de pesquisa, ensino, produção e controle de qualidade de acordo com a finalidade da instituição. Para isso a estratégia metodológica utilizada foram estudos de casos, sendo as unidades de análise dois biotérios de uma IPES um de produção e um de experimentação. Os métodos utilizados foram a pesquisa bibliográfica, visitas técnicas e entrevistas, questionários e levantamentos arquitetônico- construtivos a fim de determinar as características construtivas, arquitetônicas e funcionais, além das condições de exposição ambiental relevantes a qualidade do ar interior nas unidades de análise. Além disso, foram feitas medições dos principais gases poluentes nos ambientes de permanência dos animais, amônia (NH 3 ) e dióxido de carbono (CO 2 ) e de temperatura do ar, umidade relativa do ar e velocidade do ar. Para estas medições foi feito um refinamento dos pontos de medição segundo uma malha ortogonal com pontos distribuídos uniformemente nas salas. Além disso, foram definidas duas alturas de medições a fim de analisar uma provável diferença de concentrações. Foram feitas medições de velocidade do ar, junto aos equipamentos de condicionamento ambiental e frestas das portas visando identificar a vazão de ar relacionada a possíveis infiltrações. Com os resultados foi possível identificar as principais variáveis que influenciam a qualidade do ar interior nas salas onde permanecem os animais em biotérios. / The present study sought to investigate and interrelate architectural- construction conditions and quality of indoor air environments of stay of animals in animal facilities at Public Institution of Higher Education, since they are indoors, with little ventilation and need maximum control because of the specific environmental of their activities - creation and maintenance of species used in experiments to address research programs, education, production and quality control in accordance with the purpose of the institution. For this, the methodological approach were case studies, with the units of analysis of the Public Institution of Higher Education two premises - one for production and experimentation. The methods used were literature, technical visits and interviews, questionnaires and architectural-construction surveys to determine the characteristics of construction, architectural and functional addition to the environmental exposure conditions relevant to indoor air quality in the units of analysis. In addition, measurements were made of the main gaseous environments of stay of animals, ammonia (NH 3 ) and carbon dioxide (CO 2 ) and air temperature, relative humidity and air velocity. For these measurements was made a refinement of the measurement points according to an orthogonal grid with points uniformly distributed in the rooms. Moreover, we defined two heights of measurement to analyze a possible difference in concentrations. Measurements were made of air velocity, along with environmental conditioning equipment and gaps in doors to identify the air flow related to possible leaks. The results made it possible to identify the key variables that influence indoor air quality in rooms where the animals remain in animal houses.

Page generated in 0.0645 seconds