Influência do confinamento na resistência e ductilidade de pilares curtos de concreto de ultra alta resistência submetidos à compressão centrada / Influence of confinement on strength and ductility of short ultra high strength concrete columns subjected to compressive force

Viapiana, Lincoln Grass 17 March 2016 (has links)
Neste estudo foram analisados experimentalmente o comportamento de 24 pilares curtos de Concreto de Ultra Alta Resistência - CUAR, confinados por armaduras helicoidais, avaliando especificamente os acréscimos de resistência e ductilidade obtidos com diferentes níveis de pressão lateral de confinamento. Na etapa experimental foram realizados ensaios de pilares curtos de CUAR com as seguintes características: - seção circular de 7,2 cm de diâmetro e comprimento de 23 cm, e quatro níveis de resistência à compressão do concreto sendo eles, 165, 175, 200 e 229 MPa, dosados sem e com adição de fibras metálicas; - diferentes espaçamentos das armaduras helicoidais, de modo que fossem obtidas situações com baixo, médio e alto índice de confinamento e taxa de armadura longitudinal fixa. Os ensaios de compressão centrada foram realizados com controle de deslocamento, de modo que foram obtidas as curvas força x deslocamento completas. Constatou-se que a seção resistente dos pilares de CUAR é a formada pelo núcleo de concreto confinado, área delimitada pelo eixo da armadura transversal. Observou-se que o CUAR com fibras metálicas apresenta maior deformação do núcleo de concreto confinado em relação ao núcleo de concreto confinado de CUAR sem adição de fibras metálicas, indicando dessa forma, que os pilares de CUAR com fibras metálicas apresentam comportamento mais dúctil. Para as situações de alto confinamento foram gerados ao concreto do núcleo confinado significativos acréscimos de resistência e deformação axial, aumentando a resistência do concreto confinado em relação a resistência do concreto não confinado em: 82,26%, 75,34%, 90,46% e 70,51%, respectivamente, e as deformações axiais do concreto confinado em relação a deformação axial do concreto não confinado em: 433%, 474%, 647% e 550%. Finalmente, acredita-se que os resultados obtidos poderão trazer subsídios para aplicações futuras desta técnica de confinamento na construção de novos elementos estruturais e no reforço de pilares submetidos a elevados níveis de solicitação axial. / This study evaluated experimentally the behavior of 24 short columns of Ultra High Strength Concrete - UHSC confined by helical transverse reinforcement, specifically evaluating strength increases and ductility obtained with different levels of lateral pressure of confinement. In the experimental phase short UHSC columns with the following characteristics were tested: - circular cross section of 7.2 cm diameter and 23 cm length, four levels of concrete strength (165, 175, 200 and 229 MPa), with and without addition of metallic fibers; - different spacing of transverse reinforcement, so that situations were obtained with low, medium and high level of confinement, while the longitudinal reinforcement ratio was fixed. The centered compression tests were conducted with displacement control, so that complete force x displacement curves were obtained. It was found that the resistant section of UHSC columns is formed by the confined concrete core delimited by the axis of the transverse reinforcement. It was observed that the axial displacement reached in columns with steel fibers was higher than without fibers, indicating that columns with steel fibers exhibit more ductile behavior. For high confinement levels significant axial strength and displacement increases were observed. Increases of axial strength of confined concrete in comparison to unconfined concrete were 82.26%, 75.34%, 90, 46% and 70.51%. Axial displacements were increased by 433%, 474%, 647% and 550%. Finally, it is believed that the results could provide information for future applications of this technique in construction of a new type of columns or in strengthening of columns subjected to high levels of axial force.
2

Resistência e ductilidade das ligações laje-pilar em lajes-cogumelo de concreto de alta resistência armado com fibras de aço e armadura transversal de pinos / Resistance and ductiliy of slab-column connections on high strength concrete flat slabs with steel fibers and shear reinforcement

Azevedo, Aline Passos de 22 April 1999 (has links)
Neste trabalho analisa-se a resistência à punção e a ductilidade das ligações laje-pilar em doze modelos de lajes-cogumelo de concreto armado, nas quais se efetuam combinações de emprego de concreto de alta resistência, diferentes volumes de fibras de aço e uso de armadura transversal na forma de conectores de aço tipo pino. Todas as lajes são quadradas com 1160 mm de lado e 100 mm de espessura. A armadura de flexão foi composta de barras de aço de 10 mm espaçadas de tal forma a resistir a um momento fletor único em ambas direções. Os conectores, quando utilizados, foram dispostos radialmente e compostos de barras de aço de 6.6 mm soldadas a segmentos de ferro chato nas duas extremidades. Para avaliar a capacidade resistente dos modelos de ligação laje-pilar e observar o ganho de ductilidade que as fibras proporcionam, foram ensaiados segmentos-de-laje, os quais representam uma faixa destes modelos de ligação laje-pilar. Foi utilizado um sistema de ensaio dotado de atuador hidráulico servo-controlado, programado para ensaio com deformação controlada e aquisição contínua dos dados, o que permitiu a avaliação do comportamento pós-pico de resistência e a realização de medições de resistência residual. Várias hipóteses de cálculo foram utilizadas para avaliar a resistência última das ligações laje-pilar. Empregou-se um critério de classificação para caracterizar o tipo de ruptura em: punção ou flexão predominante ou uma combinação de punção-flexão. Constatou-se que o emprego de concreto de alta resistência, juntamente com armadura transversal, aumenta substancialmente a resistência da ligação laje-pilar, e quando combinado com fibras de aço, consegue-se um considerável aumento da ductilidade. / This work analyses the punching shear resistance and ductility of slab-column connections on twelve concrete flat slab models. The model characteristics resulted from combinations of the application of high or ordinary strength concrete, different steel fiber volume fractions and use or not of shear reinforcement. All the slabs are square with 1,160 mm of side and 100 mm of thickness. The main flexural reinforcement was composed of 10 mm steel bars spaced in such a way to resist to the same bending moment in both directions. When used, the shear reinforcement of steel studs were disposed in radial directions and consisted of 6.6 mm steel bars welded to flat steel segments in their ends. To evaluate the resistant capacity of slab-column connection models and to observe the ductility that the fibers provide, they were rehearsed segments-of-slab, which represents a strip of these slab-column connection models. A testing system with a servo-controlled hydraulic jack was used and it was programmed for a controlled deformation test and continuous data acquisition. This method allowed the evaluation of the post-peak strength behavior and the measurement of residual resistance forces. Several calculations hypotheses were used to evaluate the ultimate strength of the slab-column connections. A classification criterium was applied to characterize the failure type as: predominant punching or flexure or a combination of punching-flexure. It was verified that the application of high strength concrete, together with shear reinforcement, increases substantially the slab-column connection strength, and, when combined with steel fibers, a considerable ductility increase is achieved.
3

Resistência e ductilidade das ligações laje-pilar em lajes-cogumelo de concreto de alta resistência armado com fibras de aço e armadura transversal de pinos / Resistance and ductiliy of slab-column connections on high strength concrete flat slabs with steel fibers and shear reinforcement

Aline Passos de Azevedo 22 April 1999 (has links)
Neste trabalho analisa-se a resistência à punção e a ductilidade das ligações laje-pilar em doze modelos de lajes-cogumelo de concreto armado, nas quais se efetuam combinações de emprego de concreto de alta resistência, diferentes volumes de fibras de aço e uso de armadura transversal na forma de conectores de aço tipo pino. Todas as lajes são quadradas com 1160 mm de lado e 100 mm de espessura. A armadura de flexão foi composta de barras de aço de 10 mm espaçadas de tal forma a resistir a um momento fletor único em ambas direções. Os conectores, quando utilizados, foram dispostos radialmente e compostos de barras de aço de 6.6 mm soldadas a segmentos de ferro chato nas duas extremidades. Para avaliar a capacidade resistente dos modelos de ligação laje-pilar e observar o ganho de ductilidade que as fibras proporcionam, foram ensaiados segmentos-de-laje, os quais representam uma faixa destes modelos de ligação laje-pilar. Foi utilizado um sistema de ensaio dotado de atuador hidráulico servo-controlado, programado para ensaio com deformação controlada e aquisição contínua dos dados, o que permitiu a avaliação do comportamento pós-pico de resistência e a realização de medições de resistência residual. Várias hipóteses de cálculo foram utilizadas para avaliar a resistência última das ligações laje-pilar. Empregou-se um critério de classificação para caracterizar o tipo de ruptura em: punção ou flexão predominante ou uma combinação de punção-flexão. Constatou-se que o emprego de concreto de alta resistência, juntamente com armadura transversal, aumenta substancialmente a resistência da ligação laje-pilar, e quando combinado com fibras de aço, consegue-se um considerável aumento da ductilidade. / This work analyses the punching shear resistance and ductility of slab-column connections on twelve concrete flat slab models. The model characteristics resulted from combinations of the application of high or ordinary strength concrete, different steel fiber volume fractions and use or not of shear reinforcement. All the slabs are square with 1,160 mm of side and 100 mm of thickness. The main flexural reinforcement was composed of 10 mm steel bars spaced in such a way to resist to the same bending moment in both directions. When used, the shear reinforcement of steel studs were disposed in radial directions and consisted of 6.6 mm steel bars welded to flat steel segments in their ends. To evaluate the resistant capacity of slab-column connection models and to observe the ductility that the fibers provide, they were rehearsed segments-of-slab, which represents a strip of these slab-column connection models. A testing system with a servo-controlled hydraulic jack was used and it was programmed for a controlled deformation test and continuous data acquisition. This method allowed the evaluation of the post-peak strength behavior and the measurement of residual resistance forces. Several calculations hypotheses were used to evaluate the ultimate strength of the slab-column connections. A classification criterium was applied to characterize the failure type as: predominant punching or flexure or a combination of punching-flexure. It was verified that the application of high strength concrete, together with shear reinforcement, increases substantially the slab-column connection strength, and, when combined with steel fibers, a considerable ductility increase is achieved.
4

Influência do confinamento na resistência e ductilidade de pilares curtos de concreto de ultra alta resistência submetidos à compressão centrada / Influence of confinement on strength and ductility of short ultra high strength concrete columns subjected to compressive force

Lincoln Grass Viapiana 17 March 2016 (has links)
Neste estudo foram analisados experimentalmente o comportamento de 24 pilares curtos de Concreto de Ultra Alta Resistência - CUAR, confinados por armaduras helicoidais, avaliando especificamente os acréscimos de resistência e ductilidade obtidos com diferentes níveis de pressão lateral de confinamento. Na etapa experimental foram realizados ensaios de pilares curtos de CUAR com as seguintes características: - seção circular de 7,2 cm de diâmetro e comprimento de 23 cm, e quatro níveis de resistência à compressão do concreto sendo eles, 165, 175, 200 e 229 MPa, dosados sem e com adição de fibras metálicas; - diferentes espaçamentos das armaduras helicoidais, de modo que fossem obtidas situações com baixo, médio e alto índice de confinamento e taxa de armadura longitudinal fixa. Os ensaios de compressão centrada foram realizados com controle de deslocamento, de modo que foram obtidas as curvas força x deslocamento completas. Constatou-se que a seção resistente dos pilares de CUAR é a formada pelo núcleo de concreto confinado, área delimitada pelo eixo da armadura transversal. Observou-se que o CUAR com fibras metálicas apresenta maior deformação do núcleo de concreto confinado em relação ao núcleo de concreto confinado de CUAR sem adição de fibras metálicas, indicando dessa forma, que os pilares de CUAR com fibras metálicas apresentam comportamento mais dúctil. Para as situações de alto confinamento foram gerados ao concreto do núcleo confinado significativos acréscimos de resistência e deformação axial, aumentando a resistência do concreto confinado em relação a resistência do concreto não confinado em: 82,26%, 75,34%, 90,46% e 70,51%, respectivamente, e as deformações axiais do concreto confinado em relação a deformação axial do concreto não confinado em: 433%, 474%, 647% e 550%. Finalmente, acredita-se que os resultados obtidos poderão trazer subsídios para aplicações futuras desta técnica de confinamento na construção de novos elementos estruturais e no reforço de pilares submetidos a elevados níveis de solicitação axial. / This study evaluated experimentally the behavior of 24 short columns of Ultra High Strength Concrete - UHSC confined by helical transverse reinforcement, specifically evaluating strength increases and ductility obtained with different levels of lateral pressure of confinement. In the experimental phase short UHSC columns with the following characteristics were tested: - circular cross section of 7.2 cm diameter and 23 cm length, four levels of concrete strength (165, 175, 200 and 229 MPa), with and without addition of metallic fibers; - different spacing of transverse reinforcement, so that situations were obtained with low, medium and high level of confinement, while the longitudinal reinforcement ratio was fixed. The centered compression tests were conducted with displacement control, so that complete force x displacement curves were obtained. It was found that the resistant section of UHSC columns is formed by the confined concrete core delimited by the axis of the transverse reinforcement. It was observed that the axial displacement reached in columns with steel fibers was higher than without fibers, indicating that columns with steel fibers exhibit more ductile behavior. For high confinement levels significant axial strength and displacement increases were observed. Increases of axial strength of confined concrete in comparison to unconfined concrete were 82.26%, 75.34%, 90, 46% and 70.51%. Axial displacements were increased by 433%, 474%, 647% and 550%. Finally, it is believed that the results could provide information for future applications of this technique in construction of a new type of columns or in strengthening of columns subjected to high levels of axial force.
5

Contribuição à análise da resistência à força cortante em lajes de concreto estrutural sem armadura transversal / Contribution to the analysis of shear strength in structural concrete slabs without transverse reinforcement

Sousa, Alex Micael Dantas de 18 March 2019 (has links)
A resistência à força cortante em lajes de pontes sem armadura transversal têm sido um aspecto preocupante nas verificações de estruturas de concreto estrutural construídas décadas passadas e está diretamente relacionado aos modelos de cálculo de resistência à força cortante e de largura colaborante empregados no caso de cargas parcialmente distribuídas próximas do apoio. Entretanto, não existem ainda estudos nacionais relacionados ao nível de acurácia e precisão das abordagens geralmente empregadas na prática de projetos de pontes no Brasil. Por esta razão, propõem-se apresentar uma contribuição às análises de resistência à força cortante em lajes de pontes com ênfase no modelo de cálculo da ABNT NBR 6118:2014. Para isto foram comparados os resultados experimentais e teóricos utilizando diferentes modelos de resistência à força cortante e uma base de dados construída a partir de 642 resultados experimentais. Posteriormente, alguns modelos experimentais foram explorados por meio de simulações numéricas em elementos finitos no intuito de avaliar o nível de aproximações desta abordagem e investigar a influência de parâmetros como mísulas na proximidade dos apoios. Dentre os principais resultados desta pesquisa destaca-se que o valor médio da relação entre a resistência à força cortante teórica e experimental Vexp/Vcal utilizando a ABNT NBR 6118:2014 variou de 2,145 a 1,140 conforme o modelo de largura colaborante utilizado. Enquanto isso, os modelos numéricos calibrados apresentaram relação Vexp/VMEF variando entre 0,95 e 1,01 e com coeficientes de variação menores que 15%. De maneira geral, identificou-se que os modelos de resistência à força cortante apresentam elevados níveis de dispersão entre resultados teóricos e experimentais no caso de lajes e faixas de laje e que os modelos mais usuais de definição da largura colaborante não são precisamente adequados para o caso de cargas parcialmente distribuídas próximas do apoio. / The shear strength in bridge slabs without transverse reinforcement has been a matter of concern in structural concrete structures checks built in the past decades and is directly related to the shear force and effective width calculation models employed in the case of partially distributed loads close to the support. However, there are still no national studies related to the level of accuracy and precision of the approaches commonly used in the practice of bridge projects in Brazil. For this reason, it is proposed to contribute to the shear strength analyzes in bridge slabs with emphasis on the calculation model of ABNT NBR 6118: 2014. For this, we compared the experimental and theoretical results using different models of shear strength and a database constructed from 642 experimental results. Subsequently, some experimental models were explored by means of numerical simulations in finite elements in order to evaluate the level of approximations of this approach and to investigate the influence of parameters such as greater thickness close to the supports. Among the main results of this research, it is worth noting that the average value of the relationship between theoretical and experimental shear strength Vexp/Vcal using ABNT NBR 6118: 2014 varied from 2,145 to 1,140 according to the effective width model used. Meanwhile, the calibrated numerical models showed Vexp/VMEF ratio varying between 0.95 and 1.01 and with coefficients of variation lower than 15%. In general, it was identified that the shear strength models present high levels of dispersion between theoretical and experimental results in the case of slabs and slab strips and that the most usual models of defining the effective width are not precisely adequate for the partially distributed loads close to the support in slabs.
6

Estudo de colunas curtas de concreto confinadas / Study of confined concrete short columns

Rivetti, Marianna Luna Sousa 27 June 2013 (has links)
The confinement of concrete structures has been used for reinforcement and rehabilitation of compressed structural elements, with the objective of increasing their strength capacity and ductility. Various types of reinforcement are used: metal pipes, fiber reinforced polymers, transverse reinforcement, among others. Understanding the stress-strain behavior of confined concrete columns is an important aspect to be considered in the design of these structural elements. This work presents a study of short columns of concrete confined by transverse reinforcement and fiber reinforced polymers subjected to the centered load, employing a nonlinear theoretical model that allows obtaining the stress-strain curves. Concrete columns with various strength levels and different cross-sectional shapes are considered. The employed model is modified according with the type of analyzed problem and a comparative analysis is carried out to verify the performance of the models, considering the experimental results from several examples of short columns confined available in the literature. / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / O confinamento de estruturas de concreto vem sendo utilizado no reforço e reabilitação de peças comprimidas, com o objetivo de aumentar sua capacidade resistente e dutilidade. Vários tipos de reforços são usados: tubos metálicos, polímeros reforçados com fibras, armaduras transversais, entre outros. A compreensão do comportamento tensão-deformação de colunas de concreto confinadas é um aspecto importante a considerar para um projeto confiável desses elementos estruturais. Este trabalho apresenta um estudo de colunas curtas de concreto confinadas por armadura transversal e polímeros reforçados com fibras submetidas à carga centrada, empregando um modelo teórico não linear que permite a obtenção das curvas tensão-deformação. São considerados concretos de variadas resistências e diferentes formas de seção transversal. O modelo empregado é modificado se adequando aos diversos casos analisados, e para verificação do desempenho deste é realizada uma análise comparativa considerando os resultados experimentais provenientes de vários exemplos de colunas curtas confinadas disponíveis na literatura.