• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da poluição de águas superficiais causadas pelo lançamento de percolado, provenientes do aterro controlado da Muribeca

ALMEIDA, Rosana Batista 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T17:36:48Z (GMT). No. of bitstreams: 2 arquivo2294_1.pdf: 1608202 bytes, checksum: c070af226ab41eadf46703c5dda68530 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A disposição inadequada dos resíduos sólidos urbanos, em lixões e aterros controlados, vem acarretando impactos à qualidade dos recursos hídricos superficiais. O percolado, proveniente dos Aterros de Resíduos Sólidos, quando lançado em corpos hídricos na bacia hidrográfica de influência, ocasiona alterações físicas, químicas e biológicas na qualidade da água. A implementação de Programa de monitoramento de percolado nos Aterros e nas águas superficiais é imprescindível à caracterização e avaliação dos diversos tipos de poluição hídrica, bem como na proposição de ações preventivas, corretivas e mitigadoras. O Aterro da Muribeca, localizado no município de Jaboatão dos Guararapes, no estado de Pernambuco, recebe cerca de 2.800T diárias de lixo, provenientes dos municípios de Jaboatão dos Guararapes, Moreno e Recife. O objetivo desta pesquisa é estudar o comportamento de parâmetros químicos (DBO, DQO, pH, nitritos, nitratos, sulfatos, cloretos, e metais Fe, Co, Cd, Cr, Cu, Mn e Zn), ao longo do período de 1994 a 2005, da qualidade das águas dos Rios Jaboatão dos Guararapes (Classe 3) e de seu afluente, Muribequinha (Classe 1), devido à influência do lançamento do chorume sobre esses corpos hídricos. O período de análise foi subdividido em 1º (primeiro), de agosto de 1994 a setembro de 2002; e 2º (segundo), de outubro de 2002 a agosto de 2005. Vale salientar que os dados dos parâmetros apresentam descontinuidades. As coletas de água e chorume foram distribuídas em cinco pontos: um, no chorume efluente do Aterro; dois, no Rio Jaboatão dos Guararapes e dois, no Rio Muribequinha. A poluição das águas dos Rios foi avaliada baseando-se nos padrões exigidos pelas Resoluções Conama nº 20/86 e Conama nº 357/05. No Rio Muribequinha, à jusante do recebimento do riacho de chorume, as concentrações dos parâmetros, de maneira geral, assumiram valores maiores do que as do Rio Jaboatão (em P-14). A partir do momento em que o chorume bruto deixou de ser lançado nesse Rio, houve um decréscimo nas concentrações dos parâmetros Potássio, Magnésio, Cloretos, Demanda Bioquímica de Oxigênio e Demanda Química de Oxigênio. Ao longo do período estudado, foi observada poluição pelo metal pesado Cádmio. No 2º período de análise, com exceção do Manganês, foi observada a poluição pelos demais metais. No Rio Jaboatão, a partir de outubro de 2002, a quantidade de oxigênio, necessária à degradação bioquímica da matéria orgânica, manteve-se, em quase sua totalidade, acima dos limites de referência (coleta de água em P-14), contrapondo-se com as concentrações do parâmetro que estiveram, em sua predominância, abaixo ou iguais a 10mg/L no período em que o chorume bruto era lançado diretamente no Rio Muribequinha. O percolado póstratamento, portanto, parecia ainda influenciar na poluição orgânica desse corpo hídrico. Observaram-se que as altas concentrações de fósforo podem estar relacionadas com as mais significativas precipitações total mensal e diárias, devido a possibilidade de lavagem de teores excessivos desse nutriente. Existe uma relação entre os dados de precipitação e o comportamento dos parâmetros da qualidade da água nos dois corpos hídricos O Rio Jaboatão dos Guararapes não apresentou poluição pelos metais Zinco, Ferro e Manganês, a partir dos dados disponíveis
2

Medidas da emissão de gases em oito aterros de resíduos sólidos urbanos do Estado de São Paulo - Brasil / Measurements of gas emissions at eight solid waste landfills of the state of São Paulo - Brazil

José Berto Neto 18 December 2009 (has links)
Os aterros de disposição de resíduos sólidos urbanos são equipamentos que, necessariamente, devem ser integrados ao sistema de saneamento e proteção à saúde pública das municipalidades. Independentemente se bem planejados, construídos e operados, os mesmos oferecem impactos ambientais aos locais onde estão implantados e ao seu entorno. Os referidos aterros são fontes de emissão antropogênica de gases indutores do efeito estufa global, como o metano (\'CH IND.4\') e o dióxido de carbono (\'CO IND.2\'). O presente trabalho teve por objetivo medir, estimativamente, in situ, a contribuição destes equipamentos no fluxo destes gases na natureza. Para isso, foram desenvolvidas duas campanhas em oito aterros de municípios do estado de São Paulo (Brasil) nos anos de 2006 e 2007. Foram medidas a concentrações de \'CH IND.4\' e \'CO IND.2\' no ar ambiente dos aterros, a emissão solo-ar e o fluxo a partir dos dissipadores verticais, quando presentes. As amostras coletadas do GAS foram analisadas por cromatografia gasosa. Os resultados evidenciaram que as concentrações de \'CH IND.4\' e \'CO IND.2\' na atmosfera dos aterros foram de 18.000 ppm e 5.500 ppm, respectivamente. Estes valores corresponderam a dez mil vezes e quinze vezes maiores que aquelas medidas em locais distantes dos aterros (background). Os resultados das medidas do fluxo solo-ar apontaram para uma grande variabilidade desta emissão, entre os sítios da coleta, entre os aterros e entre as campanhas. As taxas médias de emissão solo-ar variaram de 5,66 g/\'M POT.2\'.d a 148,20 g/\'M POT.2\'.d para \'CH IND.4\' e de 17,78 g/\'M POT.2\'.d a 223,04 g/\'M POT.2\'.d para \'CO IND.2\'. A emissão estimada solo-ar para os aterros variou de 276,82 a 75.730,20 toneladas por ano de \'CH IND.4\' e de 501,02 a 76.312,74 toneladas por ano para o \'CO IND.2\'. A emissão estimada para os aterros a partir dos dissipadores verticais variou de 73,52 a 307,31 toneladas para \'CH IND.4\' e de 165,83 a 692,32 toneladas por ano para o \'CO IND.2\'. Os resultados também evidenciaram que a concentração dos gases no ar ambiente dos aterros e a emissão solo-ar, especialmente, pareceram independer da operação dispensada: caso aterros sanitários, controlados ou lixões. Todos apresentaram muitas semelhanças no processo de emissão. Mesmo a presença do sistema de sucção do GAS para alimentar a usina termoelétrica (UTEB) no aterro Bandeirantes, São Paulo, Capital, não o diferenciou dos demais. De modo geral, não foi possível correlacionar variáveis que apontassem para tendências gerais na emissão destes sistemas de disposição de RSU. Com base nos resultados supracitados, este trabalho sugere futuras perspectivas de pesquisas. / Urban solid waste disposal landfills are equipments that must be integrated with the drainage and protection of the public health of municipalities system. Regardless of whether they are well planned, built and operated, they offer environmental impacts to the areas where they are deployed and their surroundings. The present work aimed at measuring, as estimates, in situ, the contribution of the aforementioned equipments in the flux of these gases in nature. The research was developed in 2006 and 2007 in two campaigns in eight municipal solid waste landfills in the state of São Paulo, Brazil. Concentrations of \'CH IND.4\' and \'CO IND.2\' were measured in the air from landfills; the ground-air emission and the flux from vertical drains, when present. The samples collected of the GAS were analyzed utilizing gas chromatography. The results showed that the concentrations of \'CH IND.4\' and \'CO IND.2\' in the atmosphere from landfills were 18,000 ppm and 5,500 ppm, respectively. These values correspond to ten thousand and fifteen times greater than those measured on places far away from landfills (background). The results of the ground-air flux indicated a great variability of this emission, not only among the collection sites, but also among the landfills and between the campaigns. The average ground-air emission ranged from 5.66 g/\'M POT.2\'.d to 148.20 g/\'M POT.2\'.d for \'CH IND.4\' and from 17.78 g/\'M POT.2\'.d to 223,04 g/\'M POT.2\'.d for \'CO IND.2\'. The estimated ground-air emission for the landfills ranged from 276.82 to 75,730.20 tons per year of \'CH IND.4\' and from 501.02 to 76,312.74 tons per year for \'CO IND.2\'. The estimated emission for the landfills from the vertical drains ranged from 73.52 to 307.31 tons per year for \'CH IND.4\' and from 165.83 to 692.32 tons per year for \'CO IND.2\'. The results also showed that concentration of gases in the environment air of landfills and the emission, especially ground-air, seems to be independent of the operation given: whether it is sanitary landfill, controlled landfill, or dump. They all presented many similarities in the emission process, and major differences among them were not elucidated. Even the presence of the suction system of the GAS to feed the thermoelectric plant (UTEB) at the Bandeirantes landfill, located at the capital of São Paulo, did not differentiate it from the other landfills from the \'CH IND.4\' and \'CO IND.2\' emission perspective. In a nutshell, it was not possible to correlate variables that pointed to general trends in the emissions of these USW disposal equipments. Based on these results, future prospects for research are suggested.
3

Medidas da emissão de gases em oito aterros de resíduos sólidos urbanos do Estado de São Paulo - Brasil / Measurements of gas emissions at eight solid waste landfills of the state of São Paulo - Brazil

Berto Neto, José 18 December 2009 (has links)
Os aterros de disposição de resíduos sólidos urbanos são equipamentos que, necessariamente, devem ser integrados ao sistema de saneamento e proteção à saúde pública das municipalidades. Independentemente se bem planejados, construídos e operados, os mesmos oferecem impactos ambientais aos locais onde estão implantados e ao seu entorno. Os referidos aterros são fontes de emissão antropogênica de gases indutores do efeito estufa global, como o metano (\'CH IND.4\') e o dióxido de carbono (\'CO IND.2\'). O presente trabalho teve por objetivo medir, estimativamente, in situ, a contribuição destes equipamentos no fluxo destes gases na natureza. Para isso, foram desenvolvidas duas campanhas em oito aterros de municípios do estado de São Paulo (Brasil) nos anos de 2006 e 2007. Foram medidas a concentrações de \'CH IND.4\' e \'CO IND.2\' no ar ambiente dos aterros, a emissão solo-ar e o fluxo a partir dos dissipadores verticais, quando presentes. As amostras coletadas do GAS foram analisadas por cromatografia gasosa. Os resultados evidenciaram que as concentrações de \'CH IND.4\' e \'CO IND.2\' na atmosfera dos aterros foram de 18.000 ppm e 5.500 ppm, respectivamente. Estes valores corresponderam a dez mil vezes e quinze vezes maiores que aquelas medidas em locais distantes dos aterros (background). Os resultados das medidas do fluxo solo-ar apontaram para uma grande variabilidade desta emissão, entre os sítios da coleta, entre os aterros e entre as campanhas. As taxas médias de emissão solo-ar variaram de 5,66 g/\'M POT.2\'.d a 148,20 g/\'M POT.2\'.d para \'CH IND.4\' e de 17,78 g/\'M POT.2\'.d a 223,04 g/\'M POT.2\'.d para \'CO IND.2\'. A emissão estimada solo-ar para os aterros variou de 276,82 a 75.730,20 toneladas por ano de \'CH IND.4\' e de 501,02 a 76.312,74 toneladas por ano para o \'CO IND.2\'. A emissão estimada para os aterros a partir dos dissipadores verticais variou de 73,52 a 307,31 toneladas para \'CH IND.4\' e de 165,83 a 692,32 toneladas por ano para o \'CO IND.2\'. Os resultados também evidenciaram que a concentração dos gases no ar ambiente dos aterros e a emissão solo-ar, especialmente, pareceram independer da operação dispensada: caso aterros sanitários, controlados ou lixões. Todos apresentaram muitas semelhanças no processo de emissão. Mesmo a presença do sistema de sucção do GAS para alimentar a usina termoelétrica (UTEB) no aterro Bandeirantes, São Paulo, Capital, não o diferenciou dos demais. De modo geral, não foi possível correlacionar variáveis que apontassem para tendências gerais na emissão destes sistemas de disposição de RSU. Com base nos resultados supracitados, este trabalho sugere futuras perspectivas de pesquisas. / Urban solid waste disposal landfills are equipments that must be integrated with the drainage and protection of the public health of municipalities system. Regardless of whether they are well planned, built and operated, they offer environmental impacts to the areas where they are deployed and their surroundings. The present work aimed at measuring, as estimates, in situ, the contribution of the aforementioned equipments in the flux of these gases in nature. The research was developed in 2006 and 2007 in two campaigns in eight municipal solid waste landfills in the state of São Paulo, Brazil. Concentrations of \'CH IND.4\' and \'CO IND.2\' were measured in the air from landfills; the ground-air emission and the flux from vertical drains, when present. The samples collected of the GAS were analyzed utilizing gas chromatography. The results showed that the concentrations of \'CH IND.4\' and \'CO IND.2\' in the atmosphere from landfills were 18,000 ppm and 5,500 ppm, respectively. These values correspond to ten thousand and fifteen times greater than those measured on places far away from landfills (background). The results of the ground-air flux indicated a great variability of this emission, not only among the collection sites, but also among the landfills and between the campaigns. The average ground-air emission ranged from 5.66 g/\'M POT.2\'.d to 148.20 g/\'M POT.2\'.d for \'CH IND.4\' and from 17.78 g/\'M POT.2\'.d to 223,04 g/\'M POT.2\'.d for \'CO IND.2\'. The estimated ground-air emission for the landfills ranged from 276.82 to 75,730.20 tons per year of \'CH IND.4\' and from 501.02 to 76,312.74 tons per year for \'CO IND.2\'. The estimated emission for the landfills from the vertical drains ranged from 73.52 to 307.31 tons per year for \'CH IND.4\' and from 165.83 to 692.32 tons per year for \'CO IND.2\'. The results also showed that concentration of gases in the environment air of landfills and the emission, especially ground-air, seems to be independent of the operation given: whether it is sanitary landfill, controlled landfill, or dump. They all presented many similarities in the emission process, and major differences among them were not elucidated. Even the presence of the suction system of the GAS to feed the thermoelectric plant (UTEB) at the Bandeirantes landfill, located at the capital of São Paulo, did not differentiate it from the other landfills from the \'CH IND.4\' and \'CO IND.2\' emission perspective. In a nutshell, it was not possible to correlate variables that pointed to general trends in the emissions of these USW disposal equipments. Based on these results, future prospects for research are suggested.

Page generated in 0.0558 seconds