• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • Tagged with
  • 7
  • 7
  • 6
  • 6
  • 5
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Teleaudiology: Clinical Outcomes from Adults with Hearing Loss

Fedt, Lauren Alexandra, Fedt, Lauren Alexandra January 2017 (has links)
Outside of major metropolitan areas, Arizona has limited options for hearing healthcare. The Arizona Affordable Hearing Aid Task Force proposed the development of a statewide program to provide low-cost hearing aids and audiologic care to low-income residents. The purpose of this review was to determine the status of the literature on the clinical outcomes of teleaudiology services for evaluations and hearing aid fittings which could be used to serve inhabitants of rural counties and address the goals of the Task Force. A literature search was performed to identify articles with original research in teleaudiology in the areas of evaluation and treatment and yielded 234 results. After exclusion criteria were applied, there were 15 articles for review; 10 articles focused on audiological evaluation and 5 articles focused on verification, validation, and counseling for hearing aid fittings. Evaluation-related articles showed that pure-tone air conduction testing was generally within the ± 5 dB acceptable range of variability, with little evidence on bone conduction or speech testing reliability. Studies reporting real-ear measurements with probe microphones were shown to yield similar results in traditional and teleaudiology fitting sessions and validation measures documented similar or better outcomes from teleaudiology fittings. Based on the literature, it is concluded that the use of teleaudiology is feasible for hearing aid fittings and counseling in rural areas, if associated barriers related to costs and limitations related to the availability of technology are overcome.
2

Identificação auditiva em crianças de 3 a 12 meses de idade com fissura labiopalatina. / Hearing identification in 3- to 12-month-old children with cleft lip and palate.

Piazentin-Penna, Sílvia Helena Alvarez 21 November 2002 (has links)
Objetivos: Verificar a ocorrência de emissões otoacústicas evocadas por estímulo transiente (EOAT) em crianças com fissura labiopalatina (FLP) e associar esses resultados com os da entrevista audiológica (EA), medidas de imitância acústica (IMIT), audiometria de observação comportamental (AOC) e audiometria de reforço visual (VRA). Local: Setor de Fonoaudiologia e de Genética Clínica - HRAC - USP. Participantes: 82 crianças com FLP não operada, de ambos os gêneros, idade entre 3 e 12 meses. Intervenções: EA, meatoscopia, AOC, VRA, IMIT, EOAT. Resultados: Os achados mostraram: presença de indicadores de risco, além da FLP, em 77% das crianças do grupo 1 (fissura transforame e pós-forame incisivo, N=48), 52% do grupo 2 (fissura pré-forame incisivo, N=29) e 40% do grupo 3 (fissura de palato submucosa, N=5); maior ocorrência de alteração na IMIT nas crianças com fissura transforame e pós-forame incisivo e a partir dos 6 meses de idade; AOC alterada em 50% das crianças do grupo 1 e 14% do grupo 2; maior ocorrência de alteração na VRA nas crianças do grupo 1, seguidas pelo grupo 2; ocorrência de EOAT em 1% das crianças do grupo 1, 55% do grupo 2 e 70% do grupo 3. Conclusões: verificamos maior ocorrência de EOAT nas crianças com fissura de palato submucosa e pré-forame incisivo; a associação entre os resultados da EOAT com os dos outros procedimentos, mostrou diferença estatisticamente significante na associação das EOAT com as IMIT das crianças de 3 a 6 meses de idade dos grupos 2 e 3 ; o uso das EOAT não mostrou ser um método adequado para a avaliação da audição de bebês com fissura de palato não operada. / Objectives: To determine the occurrence of transient evoked otoacoustic emissions evoked (TEOA) in infants with cleft lip (CL)and palate (P) and to correlate these results with those of the audiologic interview (AI), acoustic imitance (IMIT) measurements, behavioral observation audiometry (BOA), and visual reinforcement audiometry (VRA). Place: Sector of Speech Pathology and Audilogy and Clinical Genetics - HRAC - USP. Participants: 82 infants of both sexes with non-operated CLP aged 3 to 12 months. Interventions: AI, meatoscopy, BOA, VRA, IMIT, TEOA. Results: The findings showed the presence of risk indicators in addition to CLP in 77% of group 1 infants (CLP, N=48), 52% of infants of group 2 (CL, N=29 ) and 40% of children in group 3 (submucous cleft, N=5 ); a more frequent occurrence of altered IMIT in children with CLP and CP and starting at 6 months of age; altered BOA in 50% of group 1 children and 14% of group 2 children; a more frequent occurrence of altered VRA in group 1 children, followed by group 2; occurrence of EOAT in 1% of group 1 children, in 55% of group 2 children, and in 70% of group 3 children. Conclusions: we detected a more frequent occurrence of EOAT in children with submucous and CL. TEOA was significantly correlated with IMIT in children aged 3 to 6 months of groups 2 and 3; the use of TEOA did not prove to be an adequate method to assess the hearing of babies with non-operated CP.
3

Timpanometria em lactentes utilizando sonda de multifrequência / Multifrequency tympanometry in infants

Moraes, Tâmyne Ferreira Duarte de 28 February 2011 (has links)
O objetivo deste trabalho foi realizar a caracterização das medidas de imitância acústica de lactentes de zero a três meses de idade utilizando timpanometria de multifrequência. Foram avaliados 54 lactentes sem queixas auditivas e com presença de emissões otoacústicas evocadas transientes, por meio de entrevista audiológica, inspeção visual do meato acústico externo e medidas de imitância acústica nas frequências de 226Hz, 678Hz e 1000Hz, coletando-se os registros timpanométricos relacionados ao efeito de oclusão, à forma da curva timpanométrica, à pressão de pico timpanométrico, ao volume equivalente do meato acústico externo e ao pico compensado da admitância acústica estática. Os resultados indicaram presença de efeito de oclusão nas três frequências: 2,88% em 226Hz; 4,81% em 678Hz e 3,85% em 1000Hz; predomínio de curva timpanométrica em pico único (65,35% em 226Hz, 81,82% em 678Hz e 77,00% em 1000Hz); pressão de pico timpanométrico variando de -150 a 180daPa, com valores considerados normais; aumento do volume equivalente do meato acústico externo com aumento da frequência da sonda (0,64ml em 226Hz, 1,63mmho em 678Hz e 2,59mmho em 1000Hz), assim como os valores do pico compensado da admitância acústica estática (0,51ml em 226Hz, 0,55mmho em 678Hz e 1,20mmho em 1000Hz). Foram classificados como normais 93,06% dos timpanogramas realizados com 226Hz, 80,81% em 678Hz e 82,00% em 1000Hz. Por meio destas avaliações e resultados encontrados foi possível caracterizar as medidas de imitância acústica dos lactentes. / The aim of this study was to characterize acoustic immittance measures of infants from zero to three months of age using multifrequency tympanometry. 54 infants without hearing complaint and with transient evoked otoacoustic emissions presence were evaluated by an audiologic interview, a visual inspection of the ear canal and measures of acoustic immittance in the frequencies of 226Hz, 678Hz and 1000Hz, where tympanometric records of the occlusion effect, tympanometric curve type, tympanometric peak pressure, equivalent ear canal volume and peak compensated static acoustic admittance were collected. The results indicated presence of occlusion effect in three frequencies: 2.88% at 226Hz, 4.81% at 678Hz and 3.85% at 1000Hz; predominance of tympanometric curve with single peak ( 65.35% at 226Hz, 81.82% at 678Hz and 77.00% at 1000Hz), tympanometric peak pressure ranging from -155 to 180daPa with normal limits, equivalent ear canal volume increase with the frequency of the probe increase (0.64ml at 226Hz, 1.63mho at 678Hz and 2.59mmho at 1000Hz) and the increase of the peak compensated static acoustic admittance values with the frequency increase (0.51ml at 226Hz, 0.55mmho at 678Hz and 1.20mmho at 1000Hz). 93.06% of tympanograms were classified as normal at 226Hz, 81.82% at 678Hz and 77.00% at 1000Hz. Considering these evaluations and results it was possible to characterize the acoustic immittance measures of infants.
4

Identificação auditiva em crianças de 3 a 12 meses de idade com fissura labiopalatina. / Hearing identification in 3- to 12-month-old children with cleft lip and palate.

Sílvia Helena Alvarez Piazentin-Penna 21 November 2002 (has links)
Objetivos: Verificar a ocorrência de emissões otoacústicas evocadas por estímulo transiente (EOAT) em crianças com fissura labiopalatina (FLP) e associar esses resultados com os da entrevista audiológica (EA), medidas de imitância acústica (IMIT), audiometria de observação comportamental (AOC) e audiometria de reforço visual (VRA). Local: Setor de Fonoaudiologia e de Genética Clínica - HRAC - USP. Participantes: 82 crianças com FLP não operada, de ambos os gêneros, idade entre 3 e 12 meses. Intervenções: EA, meatoscopia, AOC, VRA, IMIT, EOAT. Resultados: Os achados mostraram: presença de indicadores de risco, além da FLP, em 77% das crianças do grupo 1 (fissura transforame e pós-forame incisivo, N=48), 52% do grupo 2 (fissura pré-forame incisivo, N=29) e 40% do grupo 3 (fissura de palato submucosa, N=5); maior ocorrência de alteração na IMIT nas crianças com fissura transforame e pós-forame incisivo e a partir dos 6 meses de idade; AOC alterada em 50% das crianças do grupo 1 e 14% do grupo 2; maior ocorrência de alteração na VRA nas crianças do grupo 1, seguidas pelo grupo 2; ocorrência de EOAT em 1% das crianças do grupo 1, 55% do grupo 2 e 70% do grupo 3. Conclusões: verificamos maior ocorrência de EOAT nas crianças com fissura de palato submucosa e pré-forame incisivo; a associação entre os resultados da EOAT com os dos outros procedimentos, mostrou diferença estatisticamente significante na associação das EOAT com as IMIT das crianças de 3 a 6 meses de idade dos grupos 2 e 3 ; o uso das EOAT não mostrou ser um método adequado para a avaliação da audição de bebês com fissura de palato não operada. / Objectives: To determine the occurrence of transient evoked otoacoustic emissions evoked (TEOA) in infants with cleft lip (CL)and palate (P) and to correlate these results with those of the audiologic interview (AI), acoustic imitance (IMIT) measurements, behavioral observation audiometry (BOA), and visual reinforcement audiometry (VRA). Place: Sector of Speech Pathology and Audilogy and Clinical Genetics - HRAC - USP. Participants: 82 infants of both sexes with non-operated CLP aged 3 to 12 months. Interventions: AI, meatoscopy, BOA, VRA, IMIT, TEOA. Results: The findings showed the presence of risk indicators in addition to CLP in 77% of group 1 infants (CLP, N=48), 52% of infants of group 2 (CL, N=29 ) and 40% of children in group 3 (submucous cleft, N=5 ); a more frequent occurrence of altered IMIT in children with CLP and CP and starting at 6 months of age; altered BOA in 50% of group 1 children and 14% of group 2 children; a more frequent occurrence of altered VRA in group 1 children, followed by group 2; occurrence of EOAT in 1% of group 1 children, in 55% of group 2 children, and in 70% of group 3 children. Conclusions: we detected a more frequent occurrence of EOAT in children with submucous and CL. TEOA was significantly correlated with IMIT in children aged 3 to 6 months of groups 2 and 3; the use of TEOA did not prove to be an adequate method to assess the hearing of babies with non-operated CP.
5

Timpanometria em lactentes utilizando sonda de multifrequência / Multifrequency tympanometry in infants

Tâmyne Ferreira Duarte de Moraes 28 February 2011 (has links)
O objetivo deste trabalho foi realizar a caracterização das medidas de imitância acústica de lactentes de zero a três meses de idade utilizando timpanometria de multifrequência. Foram avaliados 54 lactentes sem queixas auditivas e com presença de emissões otoacústicas evocadas transientes, por meio de entrevista audiológica, inspeção visual do meato acústico externo e medidas de imitância acústica nas frequências de 226Hz, 678Hz e 1000Hz, coletando-se os registros timpanométricos relacionados ao efeito de oclusão, à forma da curva timpanométrica, à pressão de pico timpanométrico, ao volume equivalente do meato acústico externo e ao pico compensado da admitância acústica estática. Os resultados indicaram presença de efeito de oclusão nas três frequências: 2,88% em 226Hz; 4,81% em 678Hz e 3,85% em 1000Hz; predomínio de curva timpanométrica em pico único (65,35% em 226Hz, 81,82% em 678Hz e 77,00% em 1000Hz); pressão de pico timpanométrico variando de -150 a 180daPa, com valores considerados normais; aumento do volume equivalente do meato acústico externo com aumento da frequência da sonda (0,64ml em 226Hz, 1,63mmho em 678Hz e 2,59mmho em 1000Hz), assim como os valores do pico compensado da admitância acústica estática (0,51ml em 226Hz, 0,55mmho em 678Hz e 1,20mmho em 1000Hz). Foram classificados como normais 93,06% dos timpanogramas realizados com 226Hz, 80,81% em 678Hz e 82,00% em 1000Hz. Por meio destas avaliações e resultados encontrados foi possível caracterizar as medidas de imitância acústica dos lactentes. / The aim of this study was to characterize acoustic immittance measures of infants from zero to three months of age using multifrequency tympanometry. 54 infants without hearing complaint and with transient evoked otoacoustic emissions presence were evaluated by an audiologic interview, a visual inspection of the ear canal and measures of acoustic immittance in the frequencies of 226Hz, 678Hz and 1000Hz, where tympanometric records of the occlusion effect, tympanometric curve type, tympanometric peak pressure, equivalent ear canal volume and peak compensated static acoustic admittance were collected. The results indicated presence of occlusion effect in three frequencies: 2.88% at 226Hz, 4.81% at 678Hz and 3.85% at 1000Hz; predominance of tympanometric curve with single peak ( 65.35% at 226Hz, 81.82% at 678Hz and 77.00% at 1000Hz), tympanometric peak pressure ranging from -155 to 180daPa with normal limits, equivalent ear canal volume increase with the frequency of the probe increase (0.64ml at 226Hz, 1.63mho at 678Hz and 2.59mmho at 1000Hz) and the increase of the peak compensated static acoustic admittance values with the frequency increase (0.51ml at 226Hz, 0.55mmho at 678Hz and 1.20mmho at 1000Hz). 93.06% of tympanograms were classified as normal at 226Hz, 81.82% at 678Hz and 77.00% at 1000Hz. Considering these evaluations and results it was possible to characterize the acoustic immittance measures of infants.
6

O Processo de Indicação e Adaptação de Aparelho de Amplificação Sonora Individual para crianças abaixo de três anos de idade / The process of indication and adaptation of hearing aid for chidren below of three years of age

Cordeiro, Gerissa Neiva de Moura Santos 23 February 2007 (has links)
Made available in DSpace on 2016-04-27T18:12:18Z (GMT). No. of bitstreams: 1 Gerissa Neiva de Moura Santos Cordeiro.pdf: 1391551 bytes, checksum: 3e2c4d833bd78c98e1174ab84d86e2d0 (MD5) Previous issue date: 2007-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Introduction. The process of audiologic evaluation is very important and dynamic. It occurs then the characterization of the auditory loss (degree, type and configuration), the determination of the necessities and expectations, the election of the hearing aid, being chosen its physical and eletroacustics characteristics. After that, the verification of the amplification prescribed during the programming of the hearing aid is carried through and, finally, the validation, to verify the effect in the auditory perception and the development of speaks. With this they stand out the importance of the diagnosis and the establishment of necessary auditory thresholds in the indication and adaptation of the hearing aid in children and the necessity of a knowledge deepened on the subject, that subsidizes the improvement of the politics and services of attention to the auditory health. Objetivo.Discribed and to argue the process of lapsing, verification and validation in the adaptation of hearing aid (Device of Individual Sonorous Amplification) for children of 3 the 36 months of age, inserted in a service of auditory health. Methodology. They had been selected and considered for it analyzes 10 citizens that were in attendance in the Centro Audição na Criança (CeAC), had been collected the data in the handbook of the service on the audiológico diagnosis, the indication and adaptation of the amplification and had been gotten given through measures in situ, audiometria with visual reinforcement with AASI and test of perception of speaks; in each specific case. From it analyzes had been chosen 2 citizens that had better allowed the quarrel of: Establishment of the auditory thresholds for the lapsing of characteristics acoustics of the AASI.The process of verification of the lapsing of the characteristics of the AASI: waited and the found one. Results. The results gotten with the quarrels of the two cases had disclosed that the determination of the audiométricos thresholds in the studied cases was determinative in the lapsing of the characteristics of the AASI. We presented different values of RECD in the two ears, being justified by the asymmetry of external acoustic meato that was visualized through the auricular mold. In the studied cases the value indicated in the software of the company does not correspond to the values gotten in the process of verification in coupler 2 cc. Reaction for the sounds was observed of says in both the casesConclusion. This study it allowed some reflections on the determination of the thresholds for the lapsing of the amplification. The mensuração of the RECD must be measured in the two ears when the anatomical difference will be visualized in the auricular mold. Adjustments of until 20dB had been necessary so that the parameters prescribed for software were gotten in the coupler 2cc. These results confirm the necessity of the process of verification in the coupler in the routine of the indication of AASI. The organization of a protocol with all the carried through procedures made possible one better understanding of the process and was basic in the decisions in such a way in the establishment of the thresholds as in the verification and validation of the characteristics of the AASI. It made possible the organization of a protocol suggestion that can contribute for the clinical interpretation of the available examinations in the first year of life / Introdução. O processo de avaliação audiológica é muito importante e dinâmico. Ocorre então a caracterização da perda auditiva (grau, tipo e configuração), a determinação das necessidades e expectativas, a seleção do AASI, sendo escolhidas suas características físicas e eletroacústicas. Em seguida, é realizada a verificação da amplificação prescrita durante a programação do AASI e, por último, a validação, para se verificar o efeito na percepção auditiva e no desenvolvimento de fala.Com isso ressaltam a importância do diagnóstico e do estabelecimento de limiares auditivos precisos na indicação e adaptação do AASI em crianças e a necessidade de um conhecimento aprofundado sobre o tema, que subsidie o aprimoramento das políticas e serviços de atenção à saúde auditiva. Objetivo.Descrever e discutir o processo de prescrição, verificação e validação na adaptação de AASI (Aparelho de Amplificação Sonora Individual) para crianças de 3 a 36 meses de idade, inseridas em um serviço de saúde auditiva.Metodologia. Foram selecionados e considerados para analise 10 sujeitos que estavam em atendimento no Centro Audição na Criança (CeAC), foram coletados os dados no prontuário do serviço sobre o diagnóstico audiológico, sobre a indicação e adaptação da amplificação e foram obtidos dados através de medidas in situ, audiometria com reforço visual com AASI e teste de percepção de fala; em cada caso específico.A partir da analise foram escolhidos 2 sujeitos que melhor permitiram a discussão de: Estabelecimento dos limiares auditivos para a prescrição de características acústicas do AASI.O processo de verificação da prescrição das características do AASI: o esperado e o encontrado.Resultados. Os resultados obtidos com as discussões dos dois casos revelaram que a determinação dos limiares audiométricos nos casos estudados foi determinante na prescrição das características do AASI. We apresentou valores de RECD diferentes nas duas orelhas, sendo justificada pela assimetria de meato acústico externo que foi visualizado através do molde auricular. Nos casos estudados o valor indicado no software da empresa não correspondem aos valores obtidos no processo de verificação no acoplador 2 cc.Foi observada reação para os sons de fala em ambos os casos Conclusão.Este estudo permitiu algumas reflexões sobre a determinação dos limiares para a prescrição da amplificação. A mensuração do RECD deve ser medido nas duas orelhas quando for visualizado no molde auricular a diferença anatômica..Ajustes de até 20dB foram necessários para que os parâmetros prescritos pelo software fossem obtidos no acoplador 2cc.Estes resultados confirmam a necessidade do processo de verificação no acoplador na rotina da indicação de AASI. A organização de um protocolo com todos os procedimentos realizados possibilitou uma melhor compreensão do processo e foi fundamental nas decisões tanto no estabelecimento dos limiares como na verificação validação das características do AASI. Possibilitou a organização de uma sugestão de protocolo que pode contribuir para a interpretação clínica dos exames disponíveis no primeiro ano de vida
7

Processos de (inter)compreensão nas afasias : um estudo neurolinguístico na perspectiva bakhtiniana / (Inter)comprehension in aphasia : neurolinguistic study in the bakhtinian perspective

Fugiwara, Renata Viana Ensinas, 1979- 12 May 2013 (has links)
Orientador: Rosana do Carmo Novaes Pinto / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Estudos da Linguagem / Made available in DSpace on 2018-08-24T05:21:21Z (GMT). No. of bitstreams: 1 Fugiwara_RenataVianaEnsinas_D.pdf: 14015900 bytes, checksum: 719265ec3811cf0c6699c0fd25a5ada2 (MD5) Previous issue date: 2013 / Resumo: Este trabalho visa abordar o tema da (inter) compreensão no campo das afasias, pautado na perspectiva bakhtiniana, que a concebe como compreensão ativo-responsiva, já que, para Bakhtin, compreender é atribuir às palavras do Outro palavras próprias. Trata-se de uma abordagem que questiona, já de inicio, a dicotomia entre produção e compreensão que caracteriza os estudos neuropsicológicos tradicionais e também as noções de decodificação ou de identificação subjacentes aos modelos de processamento de linguagem. Para ampliarmos o olhar para as dificuldades de compreensão nas afasias, incorporamos questões relativas ao funcionamento auditivo, que pode ser considerado uma das facetas do processo de compreensão - a sua interface sensorial. Avaliamos sujeitos fluentes e não-fluentes em tarefas metalinguísticas elaboradas para testar a compreensão, utilizando subtestes das baterias de Boston (Boston Diagnostic Aphasia Examination), de Goodglass & Kaplan (1995) e PALPA (Psycholinguistic Assessments of Language Processing in Aphasia), de Kay, Lesser e Coltheart (1992), visando observar dificuldades dos sujeitos com relação às unidades da língua. Posteriormente, analisamos um conjunto de dados que emergiram em episódios interativos entre sujeitos afásicos e não-afásicos, em sua maioria nas sessões coletivas do Grupo III do CCA (Centro de Convivência de Afásicos) ou em sessões de acompanhamento individual. A reflexão foi respaldada pelos resultados de análises de cunho microgenético, buscando evidenciar não apenas as dificuldades, mas também as possibilidades de (inter) compreensão construídas pelos sujeitos afásicos e pelos não-afásicos nos processos interativos, pelo trabalho que ambos operam sobre os enunciados uns dos outros. Buscamos refletir, por fim, sobre questões éticas que orientam o trabalho clínico com sujeitos afásicos e as pesquisas desenvolvidas na área de Neurolinguística Discursiva, no Instituto de Estudos da Linguagem, UNICAMP / Abstract: This work addresses the issue of (inter) comprehension in the field of aphasia based on the Bakhtinian perspective, which conceives comprehension as an active-responsive act, considering that, for Bakhtin, to comprehend is to attribute one¿s own words to the Other¿s words. It is, therefore, an approach which questions the dichotomy between production and comprehension which usually characterizes the traditional Neuropsychological studies, as well as the notions of decoding or of identification underlying the language processing models. In order to broaden the view of the difficulties of comprehension in aphasia, we incorporated issues related to the auditory functioning, which can be considered one of the facets of the phenomenon of comprehension ¿ its sensory interface. We have evaluated fluent and non-fluent individuals with aphasia in metalinguistic tasks elaborated to test comprehension, using subtests of the Boston Assessment Battery (Boston Diagnostic Aphasia Examination; Goodglass & Kaplan, 1995) and of PALPA (Psycholinguistic Assessments of Language Processing in Aphasia; Kay, Lesser and Coltheart, 1992), aiming to observe the subjects' difficulties regarding language units. After that, we have analyzed a set of data which emerged in interactive episodes among aphasic and non-aphasic subjects, mostly in the sessions of Group III of CCA (Center for Aphasic Subjects), or in individual sessions. The reflection was grounded by the results of the microgenetic analysis, seeking to highlight not only the difficulties, but also the possibilities of (inter) comprehension built by the aphasic and by the non-aphasic subjects in interactive processes, through the work which both operate on the utterances of each other. Finally, we reflected on ethical issues that guide the clinical work with aphasic subjects and the research carried out in the area of Discursive Neurolinguistics, at the Language Studies Institute, UNICAMP / Doutorado / Linguistica / Doutora em Linguística

Page generated in 0.1221 seconds