• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • Tagged with
  • 10
  • 10
  • 10
  • 10
  • 10
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ajustes das características eletroacústicas do aparelho de amplificação sonora individual com base em limiares auditivos tonais e resposta auditiva de estado estável / Hearing AID prescription based on audiometric thresholds and auditory steady state responses

Bosso, Janaina Regina 07 April 2009 (has links)
A impossibilidade de obtenção de dados audiológicos comportamentais em crianças deficientes auditivas faz com que seja necessária a utilização de testes objetivos como a resposta auditiva de estado estável (RAEE) para estimar os limiares auditivos. O objetivo deste estudo foi verificar as diferenças encontradas na seleção de características eletroacústicas do aparelho de amplificação sonora individual (AASI) com base nos limiares auditivos estimados por meio da resposta auditiva de estado estável (RAEE) em comparação com o mesmo processo realizado com base em limiares auditivos tonais. Foram estudados 28 indivíduos com deficiência auditiva neurossensorial: grupo A, composto por 10 adultos (média da idade 46,3 anos) e grupo B, composto por 18 crianças (média da idade 10,38 anos). O método prescritivo utilizado foi o Desired Sensation Level (DSL) i/o versão 4.1. A medida individualizada da RECD foi utilizada como transformador acústico. Três diferentes programações foram geradas considerando os limiares auditivos tonais nas freqüências de 0,25 a 6kHz (programação tonal completa - ProTC), os limiares auditivos tonais apenas nas freqüências de 0,5, 1, 2 e 4 kHz (programação tonal - ProT) e os limiares auditivos estimados na RAEE nas freqüências de 0,5, 1, 2 e 4 kHz (programação eletrofisiológica - ProE). A verificação da amplificação foi realizada em acoplador de 2cc. Foi realizada avaliação da percepção da fala na presença de ruído (grupo A e B) e julgamento da qualidade sonora (grupo A). Os resultados mostraram que os valores da resposta em orelha real amplificada prescrita (REAR P) foram maiores para programação baseada em limiares auditivos estimados pela RAEE. As diferenças encontradas foram significativas, para todas as intensidades testadas, nas freqüências de 0,5, 1 e 2 kHz no grupo A e em todas as freqüências no grupo B. A diferença entre a REAR P e a REAR medida em acoplador de 2cc (REAR M) foi inferior a 1,4 dB em todas as freqüências e intensidades estudadas, para os grupos A e B. Não foram encontradas diferenças entre a REAR M obtidas na ProTC e na ProT. Os valores de REAR M obtidos na ProE foram maiores do que os obtidos nas programações ProTC e ProT. Não foram encontradas diferençam significativas na avaliação da percepção da fala em adultos. Por outro lado, em crianças, foi encontrada diferença significativa na obtenção da relação sinal/ruído na ProE quando comparada com às programações ProTC e ProT. No julgamento da qualidade sonora, os resultados mostraram pior julgamento das dimensões avaliadas, na ProE. Entretanto apenas para a dimensão conforto auditivo foi encontrada diferença significativa. O resultado do presente estudo mostra que os limiares auditivos estimados pela RAEE podem ser utilizados na determinação das características eletroacústicas do AASI em adultos e crianças. / The impossibility for obtaining behavioral auditory data in children with hearing loss brings the necessity of applying objective tests as auditory steady state responses (ASSR) in order to evaluate the auditory thresholds. The objective of this study was to verify the differences found on the selection of the eletroacoustic characteristics of the hearing aid (AASI) based on the auditory thresholds, obtained by the auditory steady state responses (ASSR) in comparison with the same procedure realized, based on audiometric thresholds: A total of 28 people with sensorineural hearing loss were studied: group A comprised 10 adults (average age 46,3 years) and group B comprised 18 children (average age 10,38 years). The prescriptive method applied was Desired Sensation Level (DSL) i/o version 4.1. The individualized measurement of RECD was applied as acoustic transformer. Three different programs were generated considering the audiometric thresholds on the frequencies from 0,25 to 6kHz (complete tonal program- ProTC), the audiometric thresholds just on the frequencies 0,5, 1, 2 and 4 kHz (tonal program- ProT) and the auditory thresholds obtained by the ASSR on the frequencies 0,5, 1, 2 and 4 kHz (electrophysiological program ProE). The verification of the amplification was realized by a coupler of 2cc. The evaluation of speech recognition in noise (group A and B) and the judgment of sound quality (group A) was performed. The results showed that the Real Ear Aided Response prescribed (REAR P) were higher for the program based on the auditory thresholds estimated by the ASSR. The differences were significant, for all the levels of intensity tested, for the frequencies 0,5, 1, 2 and 2 kHz in group A and in all the frequencies in group B. The difference between REAR P and the REAR measured in coupler of 2cc (REAR M) was lower than 1,4dB for all the frequencies and intensities studied, for groups A and B. Differences were not found between the REAR M obtained on the ProTC and ProT. The results for REAR M obtained on the ProE were higher than the ones obtained on the programs ProTC and ProT. Significant differences were not found in the evaluation for the speech perception in adults. For children, significant differences were found for S/N on the ProE when compared to the program ProTC and ProT. On the evaluation of the sound quality, the results showed worse judgment of the dimensions evaluated, on the ProE. However, a significant difference was found for auditory comfort dimension. The outcomes of the present study shows that the auditory threshold obtained by the ASSR can be employed for the determination of the electroacoustic characteristics of the hearing aids in adults and children.
2

Uso de dexametasona tópica isolada e associada ao ácido hialurônico na preservação auditiva de pacientes submetidos à cirurgia de implante coclear / Hearing preservation using topical dexamethasone isolated and associated with hyaluronic acid in cochlear implantation

Ramos, Bernardo Faria 26 September 2013 (has links)
INTRODUÇÃO: A introdução dos princípios da soft surgery desencadeou busca constante pela preservação auditiva, principalmente após a expansão dos critérios de inclusão para a cirurgia do implante coclear. Esses princípios cirúrgicos, associados a novos modelos de eletrodos e ao uso de fármacos no intraoperatório, têm sido utilizados a partir do melhor conhecimento da anatomia da orelha interna e da repercussão dos mecanismos inflamatórios desencadeados pelo trauma de inserção dos eletrodos. O objetivo deste estudo é avaliar o efeito de dexametasona tópica isolada e associada ao ácido hialurônico no intraoperatório de pacientes com audição residual submetidos ao implante coclear na preservação dos limiares tonais dos mesmos. MÉTODO: Foram avaliados 18 pacientes adultos com surdez severaprofunda submetidos à cirurgia de implante coclear divididos em 3 grupos: Implante coclear como grupo-controle, grupo 1; implante coclear com uso de dexametasona tópica no intraoperatório, grupo 2; e implante coclear com uso de dexametasona tópica associada ao ácido hialurônico no intraoperatório, grupo 3. Foram comparadas as médias dos limiares tonais nas frequências de 125, 250 e 500 Hz e nas frequências de 1000, 2000 e 4000 Hz no pré-operatório e no pós-operatório. RESULTADOS: A diferença entre as médias dos limiares tonais nas frequências baixas obtidas no 6º mês de pós-operatório e no pré-operatório foi de 28,03 dB + 6,77 dB no grupo 1, 30 dB + 14,53 dB no grupo 2 e 7,23 dB + 6,12 dB no grupo 3. Houve diferença estatisticamente significante dos valores do grupo 3 em relação ao grupo 1 e 2 (p = 0,002). A diferença entre as médias dos limiares tonais nas frequências altas obtidas no 6º mês de pós-operatório e no pré-operatório foi de 11,12 dB (DP + 9,71 dB) no grupo 1, 22,77 dB (DP + 12,79 dB) e 3,89 dB (DP + 3,1 dB). Houve diferença estatística entre os grupos 2 e 3 (p = 0,01). CONCLUSÕES: A associação do uso tópico de dexametasona e ácido hialurônico no intraoperatório de pacientes submetidos à cirurgia do implante coclear foi significantemente superior ao grupo controle e ao grupo no qual foi utilizado apenas a dexametasona tópica na preservação dos limiares auditivos. Por outro lado, o uso isolado de dexametasona tópica não demonstrou resultados superiores na preservação dos limiares acústicos quando comparado ao grupo controle / INTRODUCTION: The expansion of candidacy criteria for cochlear implantation led to a constant care for hearing preservation. The in-depth knowledge of the anatomy and function of the inner ear as well as the inflammatory repercussion caused by the insertion trauma led to the development of soft surgery principles, new electrode designs and pharmacotherapy. The purpose of this study was to compare the effects of topical dexamethasone isolated and associated with hyaluronic acid in hearing preservation in cochlear implantation. METHOD: Eighteen severely to profoundly hearing impaired adult patients were evaluated and divided into 3 groups: Cochlear implantation as a control group in group 1, cochlear implantation using topical dexamethasone intraoperatively in group 2 and cochlear implantation using topical dexamethasone associated with hyaluronic acid intraoperatively in group 3. Preimplant and postimplant low frequency and high frequency pure-tone average (PTA) from 125, 250, 500 Hz and 1000, 2000, 4000 Hz were calculated and compared from unaided audiograms. RESULTS: The mean changes in the low frequency PTA of preoperative and postoperative thresholds were 28.03 dB + 6.77 dB in group 1, 30 dB + 14.53 dB in group 2 and 7.23 dB + 6.12 dB in group 3. There was statistical difference comparing group 3 with group 1 and 2 (p = 0.002). The mean changes in the high frequency PTA of preoperative and postoperative thresholds were 11.12 dB + 9.71 dB in group 1, 22.77 dB + 12.79 dB e 3.89 dB + 3.1 dB. There was statistical difference between group 2 and 3 (p = 0.01). CONCLUSIONS: The use of topical dexamethasone associated with hyaluronic acid intraoperatively in cochlear implant surgery demonstrated a statistically significant difference in the preservation of low frequency thresholds when compared with the use of isolated topical dexamethasone and a control group. The use of isolated topical dexamethasone was not superior in hearing preservation when compared to a control group
3

Ajustes das características eletroacústicas do aparelho de amplificação sonora individual com base em limiares auditivos tonais e resposta auditiva de estado estável / Hearing AID prescription based on audiometric thresholds and auditory steady state responses

Janaina Regina Bosso 07 April 2009 (has links)
A impossibilidade de obtenção de dados audiológicos comportamentais em crianças deficientes auditivas faz com que seja necessária a utilização de testes objetivos como a resposta auditiva de estado estável (RAEE) para estimar os limiares auditivos. O objetivo deste estudo foi verificar as diferenças encontradas na seleção de características eletroacústicas do aparelho de amplificação sonora individual (AASI) com base nos limiares auditivos estimados por meio da resposta auditiva de estado estável (RAEE) em comparação com o mesmo processo realizado com base em limiares auditivos tonais. Foram estudados 28 indivíduos com deficiência auditiva neurossensorial: grupo A, composto por 10 adultos (média da idade 46,3 anos) e grupo B, composto por 18 crianças (média da idade 10,38 anos). O método prescritivo utilizado foi o Desired Sensation Level (DSL) i/o versão 4.1. A medida individualizada da RECD foi utilizada como transformador acústico. Três diferentes programações foram geradas considerando os limiares auditivos tonais nas freqüências de 0,25 a 6kHz (programação tonal completa - ProTC), os limiares auditivos tonais apenas nas freqüências de 0,5, 1, 2 e 4 kHz (programação tonal - ProT) e os limiares auditivos estimados na RAEE nas freqüências de 0,5, 1, 2 e 4 kHz (programação eletrofisiológica - ProE). A verificação da amplificação foi realizada em acoplador de 2cc. Foi realizada avaliação da percepção da fala na presença de ruído (grupo A e B) e julgamento da qualidade sonora (grupo A). Os resultados mostraram que os valores da resposta em orelha real amplificada prescrita (REAR P) foram maiores para programação baseada em limiares auditivos estimados pela RAEE. As diferenças encontradas foram significativas, para todas as intensidades testadas, nas freqüências de 0,5, 1 e 2 kHz no grupo A e em todas as freqüências no grupo B. A diferença entre a REAR P e a REAR medida em acoplador de 2cc (REAR M) foi inferior a 1,4 dB em todas as freqüências e intensidades estudadas, para os grupos A e B. Não foram encontradas diferenças entre a REAR M obtidas na ProTC e na ProT. Os valores de REAR M obtidos na ProE foram maiores do que os obtidos nas programações ProTC e ProT. Não foram encontradas diferençam significativas na avaliação da percepção da fala em adultos. Por outro lado, em crianças, foi encontrada diferença significativa na obtenção da relação sinal/ruído na ProE quando comparada com às programações ProTC e ProT. No julgamento da qualidade sonora, os resultados mostraram pior julgamento das dimensões avaliadas, na ProE. Entretanto apenas para a dimensão conforto auditivo foi encontrada diferença significativa. O resultado do presente estudo mostra que os limiares auditivos estimados pela RAEE podem ser utilizados na determinação das características eletroacústicas do AASI em adultos e crianças. / The impossibility for obtaining behavioral auditory data in children with hearing loss brings the necessity of applying objective tests as auditory steady state responses (ASSR) in order to evaluate the auditory thresholds. The objective of this study was to verify the differences found on the selection of the eletroacoustic characteristics of the hearing aid (AASI) based on the auditory thresholds, obtained by the auditory steady state responses (ASSR) in comparison with the same procedure realized, based on audiometric thresholds: A total of 28 people with sensorineural hearing loss were studied: group A comprised 10 adults (average age 46,3 years) and group B comprised 18 children (average age 10,38 years). The prescriptive method applied was Desired Sensation Level (DSL) i/o version 4.1. The individualized measurement of RECD was applied as acoustic transformer. Three different programs were generated considering the audiometric thresholds on the frequencies from 0,25 to 6kHz (complete tonal program- ProTC), the audiometric thresholds just on the frequencies 0,5, 1, 2 and 4 kHz (tonal program- ProT) and the auditory thresholds obtained by the ASSR on the frequencies 0,5, 1, 2 and 4 kHz (electrophysiological program ProE). The verification of the amplification was realized by a coupler of 2cc. The evaluation of speech recognition in noise (group A and B) and the judgment of sound quality (group A) was performed. The results showed that the Real Ear Aided Response prescribed (REAR P) were higher for the program based on the auditory thresholds estimated by the ASSR. The differences were significant, for all the levels of intensity tested, for the frequencies 0,5, 1, 2 and 2 kHz in group A and in all the frequencies in group B. The difference between REAR P and the REAR measured in coupler of 2cc (REAR M) was lower than 1,4dB for all the frequencies and intensities studied, for groups A and B. Differences were not found between the REAR M obtained on the ProTC and ProT. The results for REAR M obtained on the ProE were higher than the ones obtained on the programs ProTC and ProT. Significant differences were not found in the evaluation for the speech perception in adults. For children, significant differences were found for S/N on the ProE when compared to the program ProTC and ProT. On the evaluation of the sound quality, the results showed worse judgment of the dimensions evaluated, on the ProE. However, a significant difference was found for auditory comfort dimension. The outcomes of the present study shows that the auditory threshold obtained by the ASSR can be employed for the determination of the electroacoustic characteristics of the hearing aids in adults and children.
4

Uso de dexametasona tópica isolada e associada ao ácido hialurônico na preservação auditiva de pacientes submetidos à cirurgia de implante coclear / Hearing preservation using topical dexamethasone isolated and associated with hyaluronic acid in cochlear implantation

Bernardo Faria Ramos 26 September 2013 (has links)
INTRODUÇÃO: A introdução dos princípios da soft surgery desencadeou busca constante pela preservação auditiva, principalmente após a expansão dos critérios de inclusão para a cirurgia do implante coclear. Esses princípios cirúrgicos, associados a novos modelos de eletrodos e ao uso de fármacos no intraoperatório, têm sido utilizados a partir do melhor conhecimento da anatomia da orelha interna e da repercussão dos mecanismos inflamatórios desencadeados pelo trauma de inserção dos eletrodos. O objetivo deste estudo é avaliar o efeito de dexametasona tópica isolada e associada ao ácido hialurônico no intraoperatório de pacientes com audição residual submetidos ao implante coclear na preservação dos limiares tonais dos mesmos. MÉTODO: Foram avaliados 18 pacientes adultos com surdez severaprofunda submetidos à cirurgia de implante coclear divididos em 3 grupos: Implante coclear como grupo-controle, grupo 1; implante coclear com uso de dexametasona tópica no intraoperatório, grupo 2; e implante coclear com uso de dexametasona tópica associada ao ácido hialurônico no intraoperatório, grupo 3. Foram comparadas as médias dos limiares tonais nas frequências de 125, 250 e 500 Hz e nas frequências de 1000, 2000 e 4000 Hz no pré-operatório e no pós-operatório. RESULTADOS: A diferença entre as médias dos limiares tonais nas frequências baixas obtidas no 6º mês de pós-operatório e no pré-operatório foi de 28,03 dB + 6,77 dB no grupo 1, 30 dB + 14,53 dB no grupo 2 e 7,23 dB + 6,12 dB no grupo 3. Houve diferença estatisticamente significante dos valores do grupo 3 em relação ao grupo 1 e 2 (p = 0,002). A diferença entre as médias dos limiares tonais nas frequências altas obtidas no 6º mês de pós-operatório e no pré-operatório foi de 11,12 dB (DP + 9,71 dB) no grupo 1, 22,77 dB (DP + 12,79 dB) e 3,89 dB (DP + 3,1 dB). Houve diferença estatística entre os grupos 2 e 3 (p = 0,01). CONCLUSÕES: A associação do uso tópico de dexametasona e ácido hialurônico no intraoperatório de pacientes submetidos à cirurgia do implante coclear foi significantemente superior ao grupo controle e ao grupo no qual foi utilizado apenas a dexametasona tópica na preservação dos limiares auditivos. Por outro lado, o uso isolado de dexametasona tópica não demonstrou resultados superiores na preservação dos limiares acústicos quando comparado ao grupo controle / INTRODUCTION: The expansion of candidacy criteria for cochlear implantation led to a constant care for hearing preservation. The in-depth knowledge of the anatomy and function of the inner ear as well as the inflammatory repercussion caused by the insertion trauma led to the development of soft surgery principles, new electrode designs and pharmacotherapy. The purpose of this study was to compare the effects of topical dexamethasone isolated and associated with hyaluronic acid in hearing preservation in cochlear implantation. METHOD: Eighteen severely to profoundly hearing impaired adult patients were evaluated and divided into 3 groups: Cochlear implantation as a control group in group 1, cochlear implantation using topical dexamethasone intraoperatively in group 2 and cochlear implantation using topical dexamethasone associated with hyaluronic acid intraoperatively in group 3. Preimplant and postimplant low frequency and high frequency pure-tone average (PTA) from 125, 250, 500 Hz and 1000, 2000, 4000 Hz were calculated and compared from unaided audiograms. RESULTS: The mean changes in the low frequency PTA of preoperative and postoperative thresholds were 28.03 dB + 6.77 dB in group 1, 30 dB + 14.53 dB in group 2 and 7.23 dB + 6.12 dB in group 3. There was statistical difference comparing group 3 with group 1 and 2 (p = 0.002). The mean changes in the high frequency PTA of preoperative and postoperative thresholds were 11.12 dB + 9.71 dB in group 1, 22.77 dB + 12.79 dB e 3.89 dB + 3.1 dB. There was statistical difference between group 2 and 3 (p = 0.01). CONCLUSIONS: The use of topical dexamethasone associated with hyaluronic acid intraoperatively in cochlear implant surgery demonstrated a statistically significant difference in the preservation of low frequency thresholds when compared with the use of isolated topical dexamethasone and a control group. The use of isolated topical dexamethasone was not superior in hearing preservation when compared to a control group
5

Avaliação da audição residual em candidatos  a implantes coclear atráves da resposta  auditiva de estado estável / Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response

Ramos, Henrique Faria 02 April 2013 (has links)
INTRODUÇÃO: A identificação e preservação da audição residual em candidatos a implante coclear vêm assumindo maior importância clínica. A resposta auditiva de estado estável (RAEE) pode fornecer informação frequência-específica sobre o limiar auditivo em níveis de intensidade máximos de 120 dB NA, possibilitando a investigação da audição residual. Os objetivos deste estudo são avaliar a audição residual em candidatos a implante coclear, comparando os limiares eletrofisiológicos da RAEE com os limiares psicoacústicos da audiometria nas frequências de 500, 1 000, 2 000 e 4 000 Hz. MÉTODO: Foram avaliados 40 candidatos a implante coclear (80 orelhas) com perda auditiva neurossensorial severa a profunda bilateral. A audiometria foi realizada com o tom \"warble\" nas frequências de 500, 1 000, 2 000 e 4 000 Hz com intensidade máxima de estimulação de 120 dB NA. A RAEE foi obtida através da estimulação dicótica de uma frequência de tons contínuos sinusoidais modulados 100% em amplitude exponencial e 20% em frequência, nas frequências portadoras de 500, 1 000, 2 000 e 4 000 Hz, com estimulação máxima de 117, 120, 119 e 118 dB NA, respectivamente. RESULTADOS: Foram obtidos limiares mensuráveis em 62,5% de todas as frequências estudadas na audiometria tonal e em 63,1% na RAEE. A RAEE apresentou sensibilidade de 96% e especificidade de 91,6% na detecção da audição residual. As diferenças médias entre os limiares da audiometria tonal e da RAEE não apresentaram significância estatística em nenhuma das frequências. As correlações entre os limiares comportamentais e da RAEE foram significantes em todas as frequências avaliadas, sendo fortes em 500, 1 000 e 2 000 Hz e moderada em 4 000 Hz, com coeficiente de correlação de Pearson entre 0,65 e 0,81. Em 90% dos casos, os limiares da RAEE foram adquiridos nos limites de 10 dB dos limiares comportamentais. CONCLUSÕES: As correlações entre os limiares tonais e da RAEE foram significantes nas frequências de 500, 1 000, 2 000 e 4 000 Hz. A RAEE apresentou alta sensibilidade e especificidade na detecção da audição residual em candidatos a implante coclear, em comparação com a audiometria tonal / INTRODUCTION: Identification and preservation of residual hearing in cochlear implantation are becoming more important lately. Auditory steadystate response (ASSR) can provide frequency-specific information regarding the auditory thresholds at maximum intensity levels of 120 dB HL, allowing investigation of residual hearing. The study objectives are to assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in ASSR with psychoacoustic thresholds of audiometry at 500, 1 000, 2 000 and 4 000 Hz. METHOD: Forty cochlear implant candidates (80 ears) with bilateral severe-to-profound sensorineural hearing loss were studied. Warble-tone audiometry was performed at the frequencies 500, 1 000, 2 000 e 4 000 Hz, with stimuli up to 120 dB HL. ASSR was obtained with dichotic single-frequency stimulation of sinusoidal continuous tones modulated in exponential amplitude of 100% and in frequency of 20%, at the carrier frequencies of 500, 1 000, 2 000 and 4 000 Hz at maximum stimulation levels of 117, 120, 119 and 118 dB HL, respectively. RESULTS: Thresholds were obtained in 62,5% of all frequencies evaluated in warbletone audiometry and in 63,1% in the ASSR. ASSR showed sensitivity of 96% and specificity of 91,6% in the detection of residual hearing. The mean difference between the thresholds of behavioral audiometry and ASSR were not statistically significant in any of the frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1 000 and 2 000 Hz and moderate in 4 000 Hz, with Pearson correlation coefficient between 0,65 and 0,81. In 90% of the occasions, ASSR thresholds were within 10 dB of behavioral thresholds. CONCLUSIONS: The correlations between behavioral and ASSR thresholds were significant at 500, 1 000, 2 000 and 4 000 Hz. ASSR showed high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates, compared to warble-tone audiometry
6

Avaliação da audição residual em candidatos  a implantes coclear atráves da resposta  auditiva de estado estável / Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response

Henrique Faria Ramos 02 April 2013 (has links)
INTRODUÇÃO: A identificação e preservação da audição residual em candidatos a implante coclear vêm assumindo maior importância clínica. A resposta auditiva de estado estável (RAEE) pode fornecer informação frequência-específica sobre o limiar auditivo em níveis de intensidade máximos de 120 dB NA, possibilitando a investigação da audição residual. Os objetivos deste estudo são avaliar a audição residual em candidatos a implante coclear, comparando os limiares eletrofisiológicos da RAEE com os limiares psicoacústicos da audiometria nas frequências de 500, 1 000, 2 000 e 4 000 Hz. MÉTODO: Foram avaliados 40 candidatos a implante coclear (80 orelhas) com perda auditiva neurossensorial severa a profunda bilateral. A audiometria foi realizada com o tom \"warble\" nas frequências de 500, 1 000, 2 000 e 4 000 Hz com intensidade máxima de estimulação de 120 dB NA. A RAEE foi obtida através da estimulação dicótica de uma frequência de tons contínuos sinusoidais modulados 100% em amplitude exponencial e 20% em frequência, nas frequências portadoras de 500, 1 000, 2 000 e 4 000 Hz, com estimulação máxima de 117, 120, 119 e 118 dB NA, respectivamente. RESULTADOS: Foram obtidos limiares mensuráveis em 62,5% de todas as frequências estudadas na audiometria tonal e em 63,1% na RAEE. A RAEE apresentou sensibilidade de 96% e especificidade de 91,6% na detecção da audição residual. As diferenças médias entre os limiares da audiometria tonal e da RAEE não apresentaram significância estatística em nenhuma das frequências. As correlações entre os limiares comportamentais e da RAEE foram significantes em todas as frequências avaliadas, sendo fortes em 500, 1 000 e 2 000 Hz e moderada em 4 000 Hz, com coeficiente de correlação de Pearson entre 0,65 e 0,81. Em 90% dos casos, os limiares da RAEE foram adquiridos nos limites de 10 dB dos limiares comportamentais. CONCLUSÕES: As correlações entre os limiares tonais e da RAEE foram significantes nas frequências de 500, 1 000, 2 000 e 4 000 Hz. A RAEE apresentou alta sensibilidade e especificidade na detecção da audição residual em candidatos a implante coclear, em comparação com a audiometria tonal / INTRODUCTION: Identification and preservation of residual hearing in cochlear implantation are becoming more important lately. Auditory steadystate response (ASSR) can provide frequency-specific information regarding the auditory thresholds at maximum intensity levels of 120 dB HL, allowing investigation of residual hearing. The study objectives are to assess residual hearing in cochlear implant candidates by comparing the electrophysiological thresholds obtained in ASSR with psychoacoustic thresholds of audiometry at 500, 1 000, 2 000 and 4 000 Hz. METHOD: Forty cochlear implant candidates (80 ears) with bilateral severe-to-profound sensorineural hearing loss were studied. Warble-tone audiometry was performed at the frequencies 500, 1 000, 2 000 e 4 000 Hz, with stimuli up to 120 dB HL. ASSR was obtained with dichotic single-frequency stimulation of sinusoidal continuous tones modulated in exponential amplitude of 100% and in frequency of 20%, at the carrier frequencies of 500, 1 000, 2 000 and 4 000 Hz at maximum stimulation levels of 117, 120, 119 and 118 dB HL, respectively. RESULTS: Thresholds were obtained in 62,5% of all frequencies evaluated in warbletone audiometry and in 63,1% in the ASSR. ASSR showed sensitivity of 96% and specificity of 91,6% in the detection of residual hearing. The mean difference between the thresholds of behavioral audiometry and ASSR were not statistically significant in any of the frequencies. Strong correlations between behavioral and ASSR thresholds were observed in 500, 1 000 and 2 000 Hz and moderate in 4 000 Hz, with Pearson correlation coefficient between 0,65 and 0,81. In 90% of the occasions, ASSR thresholds were within 10 dB of behavioral thresholds. CONCLUSIONS: The correlations between behavioral and ASSR thresholds were significant at 500, 1 000, 2 000 and 4 000 Hz. ASSR showed high sensitivity and specificity in the detection of residual hearing in cochlear implant candidates, compared to warble-tone audiometry
7

Comparação entre respostas auditivas de estado estável e avaliação comportamental em crianças candidatas ao implante coclear / Comparison between Auditory Steady-State Responses and behavioral audiometry in pediatric cochlear implant candidates

Beck, Roberto Miquelino de Oliveira 26 May 2015 (has links)
INTRODUÇÃO: As Respostas Auditivas de Estado Estável permitem avaliação frequência específica em intensidades de até 120 dB NA e a detecção de audição residual em pacientes com perda auditiva severo-profunda. O objetivo deste estudo é comparar os limiares à RAEE e os resultados da avaliação comportamental em crianças com suspeita de surdez severo-profunda. MÉTODO: Estudo transversal para comparar respostas à RAEE e por audiometria com reforço visual (VRA) em 63 crianças candidatas ao implante coclear (126 orelhas) com idade entre 6 e 72 meses. Foram incluídas crianças com otomicroscopia normal, ausência de respostas ao PEATE clique a 90 dB NA e às emissões otoacústicas. Foram excluídas crianças com malformações de orelha interna, doenças do espectro da neuropatia auditiva, ou que não completaram a avaliação comportamental ou não atingiram ruído eletroencefalográfico < 30 nV durante a RAEE. Foram utilizados estímulos com tons contínuos sinusoidais (100% AM e 20% FM) nas frequências de 500, 1000, 2000 e 4000 Hz em intensidade máxima de 110 dB NA. Os limiares à VRA foram obtidos por tom warble nas frequências de 500, 1000, 2000 e 4000 Hz em cada orelha através de fones de inserção (ER-5A) ou tipo casco (TDH-39). A intensidade máxima de estimulação foi de 120 dB NA em cada frequência. RESULTADOS: Limiares comportamentais foram obtidos em 36,7% (185/504) de todas as frequências em todas as crianças, 9% em intensidade maior que 110 dB NA. Entre as 504 medidas da RAEE em 63 indivíduos, 53 limiares foram obtidos (10,5%). Ao todo, 89,5% das frequências testadas não apresentaram nenhuma resposta em 110 dB NA. A distribuição dos limiares à RAEE foi semelhante à da avaliação comportamental. A maioria das respostas foram em 500 Hz, diminuindo nas frequências agudas. A diferença média entre os limiares à VRA e à RAEE variou entre 0,09 e 8,94 dB. Foram realizadas 27 comparações entre RAEE e VRA: 12 em 500 Hz, 9 em 1000 Hz, 5 em 2000 Hz e 1 em 4000 Hz. Respostas ausentes foram observadas em ambos os testes em 38,1% em 0,5 KHz, 52,45% em 1 KHz, 74,6% em 2 KHz e 81,0% em 4 KHZ. A especificidade foi > 90% em 1, 2 e 4 KHz. Nas orelhas sem resposta comportamental em 120 dB NA, todos os limiares à RAEE estavam na faixa de perda profunda, 90% deles > 110 dB NA. CONCLUSÃO: A ausência de respostas nas altas intensidades na RAEE foi o principal achado (especificidade > 90%) o que prediz limiares comportamentais na faixa de surdez profunda / Introduction and Objective: ASSR allows frequency-specific evaluation in intensities up to 120 dB HL and detection of residual hearing in patients with severe-toprofound hearing loss. The aim of this study was to compare ASSR thresholds and behavioral test results in children with suspected severe-to-profound hearing loss. Methods: A cross sectional study was carried out to compare ASSR and Visual Reinforcement Audiometry (VRA) responses in 63 pediatric cochlear implant candidates (126 ears) aged between 6 to 72 months. We included children with normal otomicroscopy findings, absent responses to click-ABR at 90 dB HL and otoaccoustic emissions. We excluded children with inner ear malformations, auditory neuropathy spectrum disorder or who did not complete VRA or achieve EEG noise < 30 nV during the ASSR test. Air-conduction ASSR stimuli were continuous sinusoidal tones (100% AM and 20% FM) presented at 0.5, 1, 2 and 4 kHz starting at the maximum presentation level of 110 dB HL. VRA thresholds were acquired with warble tones presented at 0.5, 1, 2 and 4 KHz in each ear through ER-tone 5A or TDH-39 phones. Maximum presentation level was 120 dB HL for each frequency. Results: Behavioral thresholds were obtained in 36.7% (185/504) of all frequencies in all subjects, 9% were in intensities > 110 dB HL. Among 504 ASSR measurements from 63 subjects, 53 thresholds were obtained (10.5%). Overall 89.5% of the tested frequencies did not show any response at 110 dB HL. The distribution of ASSR responses was similar to the behavioral test results. Most responses were at 500 Hz, decreasing among the higher frequencies. Mean differences between behavioral and ASSR thresholds varied from 0.09 to 8.94 dB. Overall, 27 comparisons of behavioral and ASSR thresholds were obtained: 12 at 0.5 KHz, 9 at 1 KHz, 5 at 2 KHz and 1 at 4 KHz. Absent responses were observed in both tests in 38.1% at 0.5 KHz, 52.4% at 1 KHz, 74.6% at 2 KHz and 81.0% at 4 KHz. The specificity was > 90% at 1, 2 and 4 KHz. In ears with no behavioral response at 120 dB HL all ASSR thresholds were in the profound hearing loss range, 90% of them were equal or > than 110 dB HL. Conclusion: Among 63 pediatric CI candidates, absent responses to high-intensity ASSR was the major finding (specificity > 90%) predicting behavioral thresholds in the profound hearing loss range. These findings can be helpful to confirm the decision for cochlear implantation
8

Análise molecular dos genes NEUROD4, FGFR1 e PROKR2 em pacientes com hipopituitarismo congênito / Comparison between Auditory Steady-State Responses and behavioral audiometry in pediatric cochlear implant candidates

Correa, Fernanda de Azevedo 28 May 2015 (has links)
INTRODUÇÃO: As Respostas Auditivas de Estado Estável permitem avaliação frequência específica em intensidades de até 120 dB NA e a detecção de audição residual em pacientes com perda auditiva severo-profunda. O objetivo deste estudo é comparar os limiares à RAEE e os resultados da avaliação comportamental em crianças com suspeita de surdez severo-profunda. MÉTODO: Estudo transversal para comparar respostas à RAEE e por audiometria com reforço visual (VRA) em 63 crianças candidatas ao implante coclear (126 orelhas) com idade entre 6 e 72 meses. Foram incluídas crianças com otomicroscopia normal, ausência de respostas ao PEATE clique a 90 dB NA e às emissões otoacústicas. Foram excluídas crianças com malformações de orelha interna, doenças do espectro da neuropatia auditiva, ou que não completaram a avaliação comportamental ou não atingiram ruído eletroencefalográfico < 30 nV durante a RAEE. Foram utilizados estímulos com tons contínuos sinusoidais (100% AM e 20% FM) nas frequências de 500, 1000, 2000 e 4000 Hz em intensidade máxima de 110 dB NA. Os limiares à VRA foram obtidos por tom warble nas frequências de 500, 1000, 2000 e 4000 Hz em cada orelha através de fones de inserção (ER-5A) ou tipo casco (TDH-39). A intensidade máxima de estimulação foi de 120 dB NA em cada frequência. RESULTADOS: Limiares comportamentais foram obtidos em 36,7% (185/504) de todas as frequências em todas as crianças, 9% em intensidade maior que 110 dB NA. Entre as 504 medidas da RAEE em 63 indivíduos, 53 limiares foram obtidos (10,5%). Ao todo, 89,5% das frequências testadas não apresentaram nenhuma resposta em 110 dB NA. A distribuição dos limiares à RAEE foi semelhante à da avaliação comportamental. A maioria das respostas foram em 500 Hz, diminuindo nas frequências agudas. A diferença média entre os limiares à VRA e à RAEE variou entre 0,09 e 8,94 dB. Foram realizadas 27 comparações entre RAEE e VRA: 12 em 500 Hz, 9 em 1000 Hz, 5 em 2000 Hz e 1 em 4000 Hz. Respostas ausentes foram observadas em ambos os testes em 38,1% em 0,5 KHz, 52,45% em 1 KHz, 74,6% em 2 KHz e 81,0% em 4 KHZ. A especificidade foi > 90% em 1, 2 e 4 KHz. Nas orelhas sem resposta comportamental em 120 dB NA, todos os limiares à RAEE estavam na faixa de perda profunda, 90% deles > 110 dB NA. CONCLUSÃO: A ausência de respostas nas altas intensidades na RAEE foi o principal achado (especificidade > 90%) o que prediz limiares comportamentais na faixa de surdez profunda / Introduction and Objective: ASSR allows frequency-specific evaluation in intensities up to 120 dB HL and detection of residual hearing in patients with severe-toprofound hearing loss. The aim of this study was to compare ASSR thresholds and behavioral test results in children with suspected severe-to-profound hearing loss. Methods: A cross sectional study was carried out to compare ASSR and Visual Reinforcement Audiometry (VRA) responses in 63 pediatric cochlear implant candidates (126 ears) aged between 6 to 72 months. We included children with normal otomicroscopy findings, absent responses to click-ABR at 90 dB HL and otoaccoustic emissions. We excluded children with inner ear malformations, auditory neuropathy spectrum disorder or who did not complete VRA or achieve EEG noise < 30 nV during the ASSR test. Air-conduction ASSR stimuli were continuous sinusoidal tones (100% AM and 20% FM) presented at 0.5, 1, 2 and 4 kHz starting at the maximum presentation level of 110 dB HL. VRA thresholds were acquired with warble tones presented at 0.5, 1, 2 and 4 KHz in each ear through ER-tone 5A or TDH-39 phones. Maximum presentation level was 120 dB HL for each frequency. Results: Behavioral thresholds were obtained in 36.7% (185/504) of all frequencies in all subjects, 9% were in intensities > 110 dB HL. Among 504 ASSR measurements from 63 subjects, 53 thresholds were obtained (10.5%). Overall 89.5% of the tested frequencies did not show any response at 110 dB HL. The distribution of ASSR responses was similar to the behavioral test results. Most responses were at 500 Hz, decreasing among the higher frequencies. Mean differences between behavioral and ASSR thresholds varied from 0.09 to 8.94 dB. Overall, 27 comparisons of behavioral and ASSR thresholds were obtained: 12 at 0.5 KHz, 9 at 1 KHz, 5 at 2 KHz and 1 at 4 KHz. Absent responses were observed in both tests in 38.1% at 0.5 KHz, 52.4% at 1 KHz, 74.6% at 2 KHz and 81.0% at 4 KHz. The specificity was > 90% at 1, 2 and 4 KHz. In ears with no behavioral response at 120 dB HL all ASSR thresholds were in the profound hearing loss range, 90% of them were equal or > than 110 dB HL. Conclusion: Among 63 pediatric CI candidates, absent responses to high-intensity ASSR was the major finding (specificity > 90%) predicting behavioral thresholds in the profound hearing loss range. These findings can be helpful to confirm the decision for cochlear implantation
9

Comparação entre respostas auditivas de estado estável e avaliação comportamental em crianças candidatas ao implante coclear / Comparison between Auditory Steady-State Responses and behavioral audiometry in pediatric cochlear implant candidates

Roberto Miquelino de Oliveira Beck 26 May 2015 (has links)
INTRODUÇÃO: As Respostas Auditivas de Estado Estável permitem avaliação frequência específica em intensidades de até 120 dB NA e a detecção de audição residual em pacientes com perda auditiva severo-profunda. O objetivo deste estudo é comparar os limiares à RAEE e os resultados da avaliação comportamental em crianças com suspeita de surdez severo-profunda. MÉTODO: Estudo transversal para comparar respostas à RAEE e por audiometria com reforço visual (VRA) em 63 crianças candidatas ao implante coclear (126 orelhas) com idade entre 6 e 72 meses. Foram incluídas crianças com otomicroscopia normal, ausência de respostas ao PEATE clique a 90 dB NA e às emissões otoacústicas. Foram excluídas crianças com malformações de orelha interna, doenças do espectro da neuropatia auditiva, ou que não completaram a avaliação comportamental ou não atingiram ruído eletroencefalográfico < 30 nV durante a RAEE. Foram utilizados estímulos com tons contínuos sinusoidais (100% AM e 20% FM) nas frequências de 500, 1000, 2000 e 4000 Hz em intensidade máxima de 110 dB NA. Os limiares à VRA foram obtidos por tom warble nas frequências de 500, 1000, 2000 e 4000 Hz em cada orelha através de fones de inserção (ER-5A) ou tipo casco (TDH-39). A intensidade máxima de estimulação foi de 120 dB NA em cada frequência. RESULTADOS: Limiares comportamentais foram obtidos em 36,7% (185/504) de todas as frequências em todas as crianças, 9% em intensidade maior que 110 dB NA. Entre as 504 medidas da RAEE em 63 indivíduos, 53 limiares foram obtidos (10,5%). Ao todo, 89,5% das frequências testadas não apresentaram nenhuma resposta em 110 dB NA. A distribuição dos limiares à RAEE foi semelhante à da avaliação comportamental. A maioria das respostas foram em 500 Hz, diminuindo nas frequências agudas. A diferença média entre os limiares à VRA e à RAEE variou entre 0,09 e 8,94 dB. Foram realizadas 27 comparações entre RAEE e VRA: 12 em 500 Hz, 9 em 1000 Hz, 5 em 2000 Hz e 1 em 4000 Hz. Respostas ausentes foram observadas em ambos os testes em 38,1% em 0,5 KHz, 52,45% em 1 KHz, 74,6% em 2 KHz e 81,0% em 4 KHZ. A especificidade foi > 90% em 1, 2 e 4 KHz. Nas orelhas sem resposta comportamental em 120 dB NA, todos os limiares à RAEE estavam na faixa de perda profunda, 90% deles > 110 dB NA. CONCLUSÃO: A ausência de respostas nas altas intensidades na RAEE foi o principal achado (especificidade > 90%) o que prediz limiares comportamentais na faixa de surdez profunda / Introduction and Objective: ASSR allows frequency-specific evaluation in intensities up to 120 dB HL and detection of residual hearing in patients with severe-toprofound hearing loss. The aim of this study was to compare ASSR thresholds and behavioral test results in children with suspected severe-to-profound hearing loss. Methods: A cross sectional study was carried out to compare ASSR and Visual Reinforcement Audiometry (VRA) responses in 63 pediatric cochlear implant candidates (126 ears) aged between 6 to 72 months. We included children with normal otomicroscopy findings, absent responses to click-ABR at 90 dB HL and otoaccoustic emissions. We excluded children with inner ear malformations, auditory neuropathy spectrum disorder or who did not complete VRA or achieve EEG noise < 30 nV during the ASSR test. Air-conduction ASSR stimuli were continuous sinusoidal tones (100% AM and 20% FM) presented at 0.5, 1, 2 and 4 kHz starting at the maximum presentation level of 110 dB HL. VRA thresholds were acquired with warble tones presented at 0.5, 1, 2 and 4 KHz in each ear through ER-tone 5A or TDH-39 phones. Maximum presentation level was 120 dB HL for each frequency. Results: Behavioral thresholds were obtained in 36.7% (185/504) of all frequencies in all subjects, 9% were in intensities > 110 dB HL. Among 504 ASSR measurements from 63 subjects, 53 thresholds were obtained (10.5%). Overall 89.5% of the tested frequencies did not show any response at 110 dB HL. The distribution of ASSR responses was similar to the behavioral test results. Most responses were at 500 Hz, decreasing among the higher frequencies. Mean differences between behavioral and ASSR thresholds varied from 0.09 to 8.94 dB. Overall, 27 comparisons of behavioral and ASSR thresholds were obtained: 12 at 0.5 KHz, 9 at 1 KHz, 5 at 2 KHz and 1 at 4 KHz. Absent responses were observed in both tests in 38.1% at 0.5 KHz, 52.4% at 1 KHz, 74.6% at 2 KHz and 81.0% at 4 KHz. The specificity was > 90% at 1, 2 and 4 KHz. In ears with no behavioral response at 120 dB HL all ASSR thresholds were in the profound hearing loss range, 90% of them were equal or > than 110 dB HL. Conclusion: Among 63 pediatric CI candidates, absent responses to high-intensity ASSR was the major finding (specificity > 90%) predicting behavioral thresholds in the profound hearing loss range. These findings can be helpful to confirm the decision for cochlear implantation
10

Análise molecular dos genes NEUROD4, FGFR1 e PROKR2 em pacientes com hipopituitarismo congênito / Comparison between Auditory Steady-State Responses and behavioral audiometry in pediatric cochlear implant candidates

Fernanda de Azevedo Correa 28 May 2015 (has links)
INTRODUÇÃO: As Respostas Auditivas de Estado Estável permitem avaliação frequência específica em intensidades de até 120 dB NA e a detecção de audição residual em pacientes com perda auditiva severo-profunda. O objetivo deste estudo é comparar os limiares à RAEE e os resultados da avaliação comportamental em crianças com suspeita de surdez severo-profunda. MÉTODO: Estudo transversal para comparar respostas à RAEE e por audiometria com reforço visual (VRA) em 63 crianças candidatas ao implante coclear (126 orelhas) com idade entre 6 e 72 meses. Foram incluídas crianças com otomicroscopia normal, ausência de respostas ao PEATE clique a 90 dB NA e às emissões otoacústicas. Foram excluídas crianças com malformações de orelha interna, doenças do espectro da neuropatia auditiva, ou que não completaram a avaliação comportamental ou não atingiram ruído eletroencefalográfico < 30 nV durante a RAEE. Foram utilizados estímulos com tons contínuos sinusoidais (100% AM e 20% FM) nas frequências de 500, 1000, 2000 e 4000 Hz em intensidade máxima de 110 dB NA. Os limiares à VRA foram obtidos por tom warble nas frequências de 500, 1000, 2000 e 4000 Hz em cada orelha através de fones de inserção (ER-5A) ou tipo casco (TDH-39). A intensidade máxima de estimulação foi de 120 dB NA em cada frequência. RESULTADOS: Limiares comportamentais foram obtidos em 36,7% (185/504) de todas as frequências em todas as crianças, 9% em intensidade maior que 110 dB NA. Entre as 504 medidas da RAEE em 63 indivíduos, 53 limiares foram obtidos (10,5%). Ao todo, 89,5% das frequências testadas não apresentaram nenhuma resposta em 110 dB NA. A distribuição dos limiares à RAEE foi semelhante à da avaliação comportamental. A maioria das respostas foram em 500 Hz, diminuindo nas frequências agudas. A diferença média entre os limiares à VRA e à RAEE variou entre 0,09 e 8,94 dB. Foram realizadas 27 comparações entre RAEE e VRA: 12 em 500 Hz, 9 em 1000 Hz, 5 em 2000 Hz e 1 em 4000 Hz. Respostas ausentes foram observadas em ambos os testes em 38,1% em 0,5 KHz, 52,45% em 1 KHz, 74,6% em 2 KHz e 81,0% em 4 KHZ. A especificidade foi > 90% em 1, 2 e 4 KHz. Nas orelhas sem resposta comportamental em 120 dB NA, todos os limiares à RAEE estavam na faixa de perda profunda, 90% deles > 110 dB NA. CONCLUSÃO: A ausência de respostas nas altas intensidades na RAEE foi o principal achado (especificidade > 90%) o que prediz limiares comportamentais na faixa de surdez profunda / Introduction and Objective: ASSR allows frequency-specific evaluation in intensities up to 120 dB HL and detection of residual hearing in patients with severe-toprofound hearing loss. The aim of this study was to compare ASSR thresholds and behavioral test results in children with suspected severe-to-profound hearing loss. Methods: A cross sectional study was carried out to compare ASSR and Visual Reinforcement Audiometry (VRA) responses in 63 pediatric cochlear implant candidates (126 ears) aged between 6 to 72 months. We included children with normal otomicroscopy findings, absent responses to click-ABR at 90 dB HL and otoaccoustic emissions. We excluded children with inner ear malformations, auditory neuropathy spectrum disorder or who did not complete VRA or achieve EEG noise < 30 nV during the ASSR test. Air-conduction ASSR stimuli were continuous sinusoidal tones (100% AM and 20% FM) presented at 0.5, 1, 2 and 4 kHz starting at the maximum presentation level of 110 dB HL. VRA thresholds were acquired with warble tones presented at 0.5, 1, 2 and 4 KHz in each ear through ER-tone 5A or TDH-39 phones. Maximum presentation level was 120 dB HL for each frequency. Results: Behavioral thresholds were obtained in 36.7% (185/504) of all frequencies in all subjects, 9% were in intensities > 110 dB HL. Among 504 ASSR measurements from 63 subjects, 53 thresholds were obtained (10.5%). Overall 89.5% of the tested frequencies did not show any response at 110 dB HL. The distribution of ASSR responses was similar to the behavioral test results. Most responses were at 500 Hz, decreasing among the higher frequencies. Mean differences between behavioral and ASSR thresholds varied from 0.09 to 8.94 dB. Overall, 27 comparisons of behavioral and ASSR thresholds were obtained: 12 at 0.5 KHz, 9 at 1 KHz, 5 at 2 KHz and 1 at 4 KHz. Absent responses were observed in both tests in 38.1% at 0.5 KHz, 52.4% at 1 KHz, 74.6% at 2 KHz and 81.0% at 4 KHz. The specificity was > 90% at 1, 2 and 4 KHz. In ears with no behavioral response at 120 dB HL all ASSR thresholds were in the profound hearing loss range, 90% of them were equal or > than 110 dB HL. Conclusion: Among 63 pediatric CI candidates, absent responses to high-intensity ASSR was the major finding (specificity > 90%) predicting behavioral thresholds in the profound hearing loss range. These findings can be helpful to confirm the decision for cochlear implantation

Page generated in 0.0829 seconds