• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Performance and strut efficiency factor of concrete deep beams reinforced with GFRP bars / Performance et facteur d'efficacité de la bielle de poutres profondes en béton armé avec des barres de PRFV

Mohamed, Khaled Ahmed January 2015 (has links)
Abstract : Deep reinforced concrete beams are commonly used as transfer girders or bridge bents, at which its safety is often crucial for the stability of the whole structure. Such elements are exposed to the aggressive environment in northern climates causing steel-corrosion problems due to the excessive use of de-icing salts. Fiber-reinforced polymers (FRP) emerged as non-corroded reinforcing materials to overcome such problems in RC elements. The present study aims to address the applicability of concrete deep beams totally reinforced with FRP bars. Ten full-scale deep beams with dimensions of 1200 × 300 × 5000 mm were constructed and tested to failure under two-point loading. Test variables were shear-span depth ratio (equal to 1.47, 1.13, and 0.83) and different configurations of web reinforcement (including vertical and/or horizontal web reinforcement). Failure of all specimens was preceded by crushing in the concrete diagonal strut, which is the typical failure of deep beams. The test results indicated that, all web reinforcement configurations employed in the tested specimens yielded insignificant effects on the ultimate strength. However, strength of specimens containing horizontal-only web reinforcement were unexpectedly lower than that of specimens without web reinforcement. The web reinforcement’s main contribution was significant crack-width control. The tested specimens exhibited reasonable deflection levels compared to the available steel-reinforced deep beams in the literature. The development of arch action was confirmed through the nearly uniform strain distribution along the length of the longitudinal reinforcement in all specimens. Additionally, the basic assumption of the strut-and-tie model (STM) was adequately used to predict the strain distribution along the longitudinal reinforcement, confirming the applicability of the STM for FRP-reinforced deep beams. Hence, a STM based model was proposed to predict the strength of FRP-reinforced deep beams using the experimental data, in addition to the available experimentally tested FRP-reinforced deep beams in the literature. Assessment of the available STMs in code provisions was conducted identifying the important parameters affecting the strut efficiency factor. The tendency of each parameter (concrete compressive strength, shear span-depth ratio, and strain in longitudinal reinforcement) was individually evaluated against the efficiency factor. Strain energy based calculations were performed to identify the appropriate truss model for detailing FRP-reinforced deep beams, hence, only four specimens with vertical web reinforcement exhibited the formation of two-panel truss model. The proposed model was capable to predict the ultimate capacity of the tested deep beams. The model was also verified against a compilation of a data-base of 172 steel-reinforced deep beams resulting in acceptable level of adequacy. The ultimate capacity and performance of the tested deep beams were also adequately predicted employing a 2D finite element program (VecTor2), which provide a powerful tool to predict the behavior of FRP-reinforced deep beams. The nonlinear finite element analysis was used to confirm some hypotheses associated with the experimental investigations. / Résumé : Les poutres profondes en béton armé (BA) sont couramment utilisées comme poutre de transfert ou coude de pont, comme quoi sa sécurité est souvent cruciale pour la sécurité de l’ensemble de la structure. Ces éléments sont exposés à un environnement agressif dans les climats nordiques causant des problèmes de corrosion de l’acier en raison de l’utilisation excessive de sels de déglaçage. Les polymères renforcés de fibres (PRF) sont apparus comme des matériaux de renforcement non corrodant pour surmonter ces problèmes dans les BA. La présente étude vise à examiner la question de l'applicabilité des poutres profondes en béton complètement renforcées de barres en PRF. Dix poutres profondes à grande échelle avec des dimensions de 1200 × 300 × 5000 mm ont été construites et testées jusqu’à la rupture sous chargement en deux points. Les variables testées comprenaient différents ratios de cisaillement porté/profondeur (égal à 1.47, 1.13 et 0.83) ainsi que différentes configurations d’armature dans l’âme (incluant un renforcement vertical avec ou sans renforcement horizontal). La rupture de tous les spécimens a été précédée par l’écrasement du béton dans le mât diagonal, ce qui est la rupture typique pour les poutres profondes en BA. Les résultats ont révélé que toutes les configurations de renforcement de l’âme employées dans les spécimens d'essais avaient un effet négligeable sur la résistance ultime. Toutefois, la résistance des spécimens contenant uniquement un renforcement horizontal était étonnamment inférieure à celle des spécimens sans renforcement. La contribution principale du renforcement de l’âme était dans le contrôle de la largeur de fissuration. Les spécimens examinés présentaient une déflexion raisonnable par rapport à ce qui est disponible pour les poutres profondes renforcées en acier dans la littérature. Le développement de l'effet d'arche a été confirmé par la distribution quasi uniforme des déformations le long du renforcement longitudinal dans tous les spécimens. En outre, l'hypothèse de base du modèle des bielles et tirants (MBT) a été utilisée adéquatement pour prédire la distribution de déformation le long du renforcement longitudinal, confirmant l'applicabilité du MBT pour les poutres profondes armées de PRF. Par conséquent, un modèle basé sur un MBT a été proposé afin de prédire la résistance des poutres profondes renforcées de PRF en utilisant les données expérimentales en plus de la mise à l'épreuve expérimentalement des poutres profondes renforcées de PRF trouvées dans la littérature. Une évaluation des MTB disponibles dans les dispositions des codes a été menée afin de déterminer les paramètres importants affectant le facteur d'efficacité de la bielle. La tendance de chaque paramètre (la résistance à la compression du béton, le ratio de cisaillement porté/profondeur, et la déformation dans le renforcement longitudinal) a été évaluée individuellement contre le facteur d'efficacité. Des calculs basés sur l’énergie des déformations ont été effectués pour identifier le modèle de treillis approprié afin de détailler les poutres profondes renforcées de PRF. Par conséquent, seulement quatre spécimens avec un renforcement vertical dans l’âme présentaient la formation de modèles avec deux panneaux de treillis. Le modèle proposé a été capable de prédire la capacité ultime des poutres profondes testées. Le modèle a également été vérifié contre une base de données de 172 poutres profondes renforcées en acier aboutissant en un niveau acceptable de pertinence. La capacité ultime et la performance des poutres profondes testées ont été également adéquatement prédites employant un programme d'éléments finis en 2D (VecTor2), ce qui fournira un puissant outil pour prédire le comportement des poutres profondes renforcées de PRF. L'analyse non linéaire par éléments finis a été utilisée afin de confirmer certaines hypothèses associées à l'étude expérimentale.
2

Behavior, strength and flexural stiffness of circular concrete columns reinforced with FRP bars and spirals/hoops under eccentric loading / Étude du comportement, de la capacité, et de la rigidité en flexion de colonnes circulaires en béton armé de barres et de spirales PRF chargées excentriquement

Mohamed, Ahmed Abdeldayem January 2017 (has links)
Abstract : Deterioration of concrete structures reinforced with steel bars can be seen daily in regions with aggressive weather as steel-corrosion problems worsen. Fiber-reinforced-polymers (FRP) reinforcement has proven its feasibility through different civil structural elements. Present guidelines for FRP structures in North-America and Europe have not yet handled axially loaded members, due to the lack of research and experiments. This research takes charge of providing experimental database as well as extensive analyses and design recommendations of circular concrete columns reinforced totally with different FRP bars and spirals/hoops (FRP-RC columns). Full-scale columns were tested under monotonic loading with different levels of eccentricity. Test variables included the eccentricity-to-diameter ratio (e/D); reinforcement type (GFRP and CFRP vs. steel); concrete strength; longitudinal and transverse reinforcement ratio; and confinement configuration. All specimens measured 305 mm diameter and 1500 mm height. Test results indicated that specimens reinforced with glass-FRP (GFRP) or carbon-FRP (CFRP) reached their peak strengths with no damages to GFRP or CFRP rebar on either side of specimens. Specimens with CFRP reinforcement (CFRP-RC) behaved very similarly to their steel counterparts, and achieved almost the same nominal axial forces. Specimens with GFRP reinforcement (GFRP-RC) exhibited, however, reduced stiffness and achieved lower nominal axial forces than their steel or CFRP counterparts. Failure of GFRP-RC and CFRP-RC specimens was dominated by concrete crushing at low levels of eccentricity (e/D ratios of 8.2% and 16.4%). Experimental strain results revealed that GFRP bars developed high levels of strains and stresses on the compression and tension sides and hence the GFRP-RC specimens could sustain constant axial load after peak for some time up to the limit of concrete crushing at higher levels of eccentricity (e/D ratios of 8.2% and 16.4%), which help to delay the full damage. At these levels, flexural–tension failure initiated in the GFRP-RC specimens resulting from large axial and lateral deformations and cracks on the tension side until secondary compression failure occurred due to strain limitations in concrete and degradation of the concrete compressive block. The failure of CFRP-RC specimens at higher levels of eccentricity (e/D ratios of 8.2% and 16.4%) was characterized as flexural–compression in which it took place in a less brittle manner. On the other hand, this research also included different studies to analyze the test results, evaluate rebar efficiency, and provide recommendations for analysis and design. It was, therefore, indicated that the axial and flexural capacities of the tested FRP-RC specimens could be reasonably predicted using plane sectional analysis, utilizing the equivalent rectangular stress block (ERSB) parameters given by the ACI 440.1R-15 or CSA S806-12. All predictions underestimated the actual strength with variable levels of conservatism ranged between 1.05 to 1.25 for the GFRP-RC specimens and between 1.20 to 1.40 for the CFRP-RC specimens. These levels were noticeably reduced to critical limits in specimens with high-strength concretes. An elaborate review was made to the available ERSB parameters in the present steel and FRP design standards and guidelines. Modified expressions of the ERSB given in ACI 440.1R-15 and CSA S806-12 were developed. The results indicated good correlation of predicted and measured strength values with enhanced levels of conservatism. Additionally, sets of axial force–bending moment (P-M) interaction diagrams and indicative bar charts are introduced, and recommendations drawn. The compressive-strength contribution of FRP reinforcement was thoroughly reviewed and discussed. The minimum GFRP and CFRP reinforcement ratios to avoid rebar rupturing were broadly examined. Finally, the flexure stiffness (EI) of the tested specimens was analytically determined and compared with the available expressions using experimental and analytical M-ψ responses. Proposed equations are developed and validated against the experimental results to represent the stiffness of GFRP-RC and CFRP-RC columns at service and ultimate levels. / La détérioration des structures en béton armé avec des barres d’armature d’acier peut être observée quotidiennement dans les régions à climat agressif. Le renforcement interne en polymères renforcés de fibres (PRF) a démontré sa faisabilité grâce à différents éléments structuraux en génie civil. Les lignes directrices actuelles pour les structures en béton armé de PRF en Amérique du Nord et en Europe n'ont pas encore gérées les sections soumises à des efforts axiaux excentrique, en raison du manque de recherches et d'expériences. Cette recherche permet d’augmenter la base de données expérimentales ainsi établir des analyses approfondies et des recommandations de conception pour les colonnes circulaires en béton armé complètement renforcées de PRF (barres et spirales). Des grandeur-nature colonnes ont été testées sous charge monotone avec différents niveaux d'excentricité. Les variables de test comprenaient le rapport excentricité / diamètre (e/D) ; le type de renfort (PRFV et PRFC comparativement à l’acier); la résistance du béton en compression; le taux d’armature longitudinal et transversal; et la configuration de l’armature de confinement. Tous les échantillons mesuraient 305 mm de diamètre et 1500 mm de hauteur. Les résultats des tests ont indiqué que les spécimens renforcés avec des PRF de verre ou des PRF de carbone atteignaient leur résistance maximale sans endommager les barres d’armature. Des deux types de renforcement, les spécimens de PRFCCFRP se comportaient de manière très similaire à leurs homologues en acier et atteignaient presque les mêmes résistances axiales. Cependant, les spécimens avec renforcement en PRFV ont présenté une rigidité réduite et des forces axiales nominales inférieures à celles de leurs homologues en acier ou en PRFC. Le mode de rupture des spécimens de PRFC et de PRFV a été dominé par l’écrasement du béton à de faibles niveaux d'excentricité (rapports e/D de 8,2% et 16,4%). Les résultats ont révélé que les barres de PRFV ont développé des niveaux élevés de déformations et de contraintes sur les faces en compression et en tension et, par conséquent, les spécimens de PRFVC pourraient supporter une charge axiale constante après la résistance ultime pendant un certain temps jusqu'à la limite de la rupture en compression du béton du noyau à des niveaux supérieurs d'excentricité (rapport e/D de 8,2% et 16,4%), ce qui contribue à retarder la dégradation. À ces niveaux, une rupture en tension a été initiée dans les spécimens de PRFV résultant à de grandes déformations axiales et latérales et des fissures du côté de la face en tension jusqu'à ce que la rupture en compression du béton. La rupture des spécimens de PRFC à des niveaux supérieurs d'excentricité (rapport e/D de 8,2% et 16,4%) a été caractérisé comme étant en compression du béton dans laquelle il s'est déroulé de manière moins fragile. D'autre part, cette recherche comprenait également différentes études pour analyser les résultats des tests, évaluer l'efficacité des barres d'armature et fournir des recommandations pour l'analyse et la conception. Il a donc été indiqué que les capacités axiales et de flexion des spécimens en PRF testées pourraient être raisonnablement prédites en utilisant une analyse en section plane, en utilisant les paramètres du bloc de contrainte rectangulaire équivalent (BCRE) donnés par l'ACI 440.1R-15 ou la CSA S806- 12. Toutes les prédictions ont sous-estimé la résistance réelle avec des niveaux de variabilité conservateur entre 1,05 et 1,25 pour les spécimens de PRFC et entre 1,20 et 1,40 pour les spécimens de PRFC. Ces niveaux ont été nettement réduits à des limites critiques dans les spécimens avec des bétons à haute résistance. Un examen approfondi a été effectué sur les paramètres du BCRE disponibles dans les normes et les directives de conception actuelles en acier et en PRF. Les expressions modifiées du BCRE fournies dans ACI 440.1R-15 et CSA S806-12 ont été développées. Les résultats indiquent une bonne corrélation entre les valeurs de résistance prédites et mesurées avec des niveaux accrus de conservatisme. La contribution de la résistance à la compression du renforcement en PRF a été soigneusement examinée et discutée. Le taux d’armature minimum de PRFV et de PRFC pour éviter la rupture de l'armature ont été largement examinés. Enfin, la rigidité en flexion (EI) des spécimens testés a été déterminée de manière analytique et comparée aux expressions disponibles dans la littérature en utilisant les réponses expérimentales et analytiques M-ψ. Les expressions modifiées de la rigidité en flexion EI apportées dans l’ACI 440.1R ont été développées et validées.

Page generated in 0.0558 seconds