• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 100
  • 30
  • 9
  • Tagged with
  • 137
  • 56
  • 23
  • 17
  • 16
  • 14
  • 14
  • 13
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Analyse locale des sensibilités des lectures angulaires, spectroscopiques et ellipsométriques de la Résonance des Plasmons de Surface en vue de la miniaturisation des biocapteurs optiques

Legay, Guillaume 08 September 2006 (has links) (PDF)
Les puces à ADN, dont la détection est réalisée par fluorescence, ont démontré leur efficacité pour l'identification du génome depuis plusieurs années. Cependant, si on s'intéresse à l'analyse fine des interactions mises en jeu, c'est à dire visualiser en temps réel la cinétique de l'interaction, le marquage est susceptible de changer la distribution de charges et par la même de modifier l'affinité des sites de reconnaissance. Parmi les approches s'affranchissant du marquage fluorescent, notre choix s'est porté sur une détection optique, par ellipsométrie spectroscopique et / ou par la lecture de la résonance des plasmons de surface (RPS), des interactions, présentant le compromis le plus intéressant entre sensibilité et capacité de miniaturisation. <br /><br />Ces techniques optiques reposant sur la mesure couplée de l'épaisseur et des indices optiques de la couche adsorbée. Dans une première étape, la détermination statistique par Microscopie à Force Atomique de microstructures lithographiées et fonctionnées par des monocouches biomimétiques a permis d'estimer les variations d'épaisseurs nanométriques induites par l'adsorption des molécules étudiées. Si l'ellipsométrie spectroscopique présente une très grande sensibilité ex situ à l'indice optique, l'étude angulaire de réflectivité RPS s'avère être la technique optique la plus sensible en milieu liquide. Nous avons montré, par ailleurs que la lecture spectroscopique du déphasage de la réflectivité RPS est 100 x plus sensible que l'étude angulaire et permet de déterminer séparément les épaisseurs, le modèle d'indices optiques (gradient, fraction volumique) de la couche biologique.<br /><br /> Le passage d'une analyse monocapteur à une lecture multicapteurs a été étudié par deux modes de microscopies RPS : <br />- l'imagerie en champ lointain par CCD permet outre la rapidité d'acquisition, d'intégrer 1 000 capteurs / cm2 <br />- la microscopie spectroscopique ellipsométrique à balayage, compte de tenu de la convolution du faisceau incident avec la surface microstructurée est limitée à 256 capteurs / cm2 mais présente l'avantage d'acquérir localement un spectre qui servira à une analyse paramétrique (indices optiques, fraction volumique, épaisseur).
52

Contribution à l'évaluation de l'impact sur les écosystèmes de la valorisation de résidus de procédés thermiques en BTP

Barthet, Lucile Perrodin, Yves Durrieu, Claude. January 2004 (has links)
Thèse doctorat : Sciences et Techniques du Déchet : INSA LYON : 2003. / Titre provenant de l'écran-titre. Bibliogr. p. 203-213.
53

Bio-inspired protein nanowire : electrical conductivity and use as redox mediator for enzyme wiring / Nanofils bio-inspirés constitués de protéines : conductivité électrique et utilisation comme médiateur redox

Altamura, Lucie 27 January 2015 (has links)
Nous avons développé un nano-fil conducteur, constitué uniquement de protéines et bio-inspiré des nano-fils bactériens conducteurs. Pour cela, une protéine chimère a été créée par l'association d'une protéine prion capable de s'auto-assembler en fibre et d'une métalloprotéine, une rubrédoxine, capable d'effectuer des transferts d'électrons. Comme montré par des techniques de microscopies et de spectroscopies (absorbance UV-visible et RPE), la protéine chimère est capable de former des fibres à la surface desquelles on retrouve les rubrédoxines. Les propriétés électroniques des nano-fils ont été caractérisées par des mesures courant-tension sur des échantillons secs et par électrochimie. Les mesures courant-tension ont montré que la conduction se faisait par plusieurs mécanismes. Les acides aminés aromatiques présents au centre du domaine prion semblent impliqués dans un des mécanismes de conduction. Les mesures électrochimiques ont quant à elles montré une conduction par sauts entre rubrédoxines. De plus, nous avons utilisé les nano-fils comme interface entre une enzyme, la laccase, et une électrode. Un courant électrocatalytique dû à la réduction de l'oxygène a été obtenu prouvant ainsi la capacité de nos nano-fils à agir comme médiateurs d'électrons. Les nano-fils conducteurs faits de protéines sont une structure intéressante pour comprendre le transport de charges dans les systèmes biologiques et sont également très prometteurs pour le développement de la bioélectronique et plus particulièrement de biocapteurs et de biopiles enzymatiques / The discovery of bacterial nanowires able to transport electrons on long range within biofilms and transfer them to electrodes is very promising for the development of bioelectronics and bio-electrochemical interfaces. However, their assembling process, their molecular composition and the electron transport mechanism are not fully understood yet. We took inspiration from bacterial nanowires to design conductive protein nanowires. We fused the sequence of a rubredoxin, an electron transfer iron-sulfur protein, to the sequence of HET-s(218-289), a prion domain that forms amyloid fibril by self-assembling under well-defined conditions. The resulting chimeric protein forms amyloid fibrils and displays redox proteins organized on the surface as shown by microscopy techniques and UV-Vis and EPR spectroscopy. Electron transfer mechanisms were studied in “dry state” current-voltage (I-V ) measurements and as hydrated film by electrochemistry. Dry state measurements allowed to evidence several conduction pathways with a possible role of aromatic residues in the conduction. Electrochemistry revealed electron transport by hopping between adjacent redox centers. This property allowed the use of our protein as mediator between a multicopper enzyme (laccase) and an electrode for electrocatalytic reduction of oxygen. These protein nanowires are interesting structures for the study of charge transport mechanisms in biological systems but are also very promising for the design of biosensors and enzymatic biofuel cells.
54

Étude de la régulation de la concentration extracellulaire de D-sérine et de son implication dans l'excitotoxicité

Maucler, Caroline 04 April 2013 (has links) (PDF)
La D-sérine, co-agoniste endogène du récepteur N-Méthyl D-Aspartate, est impliquée à la fois dans des fonctions physiologiques telles que l'apprentissage et le vieillissement et dans des pathologies psychiatriques et neurodégénératives comme la schizophrénie ou la sclérose latérale amyotrophique. Ce travail de thèse est composé de deux parties. Premièrement, je me suis intéressée aux mécanismes de régulation de la D-sérine extracellulaire. A l'aide de biocapteurs enzymatiques développés au laboratoire, nous avons évalué, in vivo, la diffusion de la D-sérine à travers la barrière hématoencéphalique et estimé sa concentration dans différents compartiments. Nous avons aussi montré que la recapture de la D-sérine est assurée par les transporteurs de type ASC et que sa dégradation est effectuée par la D-amino acide oxydase dans le cervelet et par la sérine racémase dans le cortex. Deuxièmement, j'ai étudié l'implication de la D-sérine dans le status épilepticus, un modèle présentant une forte excitotoxicité avérée. Nous avons tout d'abord développé une méthode de comptage automatique pour quantifier précisément la mort neuronale. Puis nous avons enregistré les concentrations de D-sérine et de glutamate extracellulaires lors du status épilepticus et nous avons montré que ces deux transmetteurs ont leur concentration augmentée dans le cortex piriforme/amygdale, zones fortement touchées par l'excitotoxicité. En revanche dans le cortex où il n'y a pas de perte neuronale excitotoxique, leur concentration reste inchangée. Mieux comprendre la régulation de la D-sérine et son rôle pathologique est essentiel pour développer et adapter des traitements
55

Conception et fabrication de capteurs et de leur technique d'interrogation pour des applications dans les domaines de la santé et de l'environnement

Sanogo, Yacouba 10 December 2012 (has links) (PDF)
Le besoin croissant de biocapteurs optiques compacts, sélectifs, ultrasensibles, rapides et bas coût dans les domaines médical et environnemental a engendré une émergence de solutions technologiques, notamment les capteurs à bases de microrésonateurs optiques. Ces types de biocapteurs sont capables de fournir une détection sélective de très faibles concentrations de biomolécules si leurs surfaces sont fonctionnalisées. En revanche, les deux méthodes optiques d'interrogation actuelles, balayage spectral et variation de l'intensité, ne peuvent ni fournir la sensibilité de la phase du signal optique propagé dans le capteur, ni les paramètres opto-géométriques (perte par propagation, l'indice effectif, coefficient de couplage, etc) nécessaires pour une modélisation de la réponse du capteur. Pour accéder à ces informations, nous avons proposé d'utiliser l'interféromètre optique à faible cohérence sensible à la phase comme une technique alternative d'interrogation et de caractérisation de microrésonateurs. La première partie des travaux de cette thèse est consacrée à l'étude de conception et de réalisation de microrésonateurs monomodes possédant un facteur de qualité supérieur à 20000 dans l'eau. Cette étude a été validée par la réalisation technologique, à l'aide des procédés de photolithographie classique et de gravure sèche au plasma d'oxygène, de microrésonateurs polymères possédant des facteurs de qualité allant jusqu'à 38 200. La deuxième partie des travaux de thèse est dédiée à l'adaptation du dispositif PS-OLCI, initialement développé au Laboratoire National de Métrologie et d'Essais (LNE) pour interroger les composants des télécommunications optiques, pour la caractérisation de microrésonateurs optiques. Les résultats obtenus en évaluant les performances spatiales et spectrales de différents microrésonateurs ont montré que le dispositif PS-OLCI n'est pas seulement un outil d'interrogation et de caractérisation mais aussi un véritable outil d'aide à la conception de microrésonateurs optiques. Une modélisation, validée par l'ajustement des mesures expérimentales, de la réponse PS-OLCI d'un microrésonateur, met en évidence la relation existant entre l'interférogramme et les intégrales de Fresnel. La dernière partie de nos travaux concerne l'association du dispositif PS-OLCI et d'un composant optofluidique, constitué de microrésonateurs et d'un circuit microfluidique en polymères, pour la détection d'espèces biologiques. A cet effet, la molécule de glucose a été choisie pour démontrer la détection homogène ou volumique en solution aqueuse en obtenant respectivement les limites de détection de l'ordre de 50 µg/ml et de 2 µg/ml en exploitant l'intensité ou la phase des mesures PS-OLCI. Ces performances démontrent la capacité de notre capteur à déceler des biomolécules en faible concentration ainsi que la pertinence de la mesure de la phase, d'où l'intérêt du dispositif PS-OLCI. Pour remédier au problème de sélectivité du capteur en détection homogène, la méthode de détection surfacique est utilisée. La problématique de chimie de surface des polymères, c'est à dire la fonctionnalisation des surfaces des guides polymères en vue d'une détection surfacique, a d'abord été effectuée. Les limites de détection obtenues en détection surfacique sont ensuite évaluées à leur tour pour différents types de molécules particulièrement les protéines telles que la streptavidine ou la biotine. Les performances de détection de streptavidine obtenues sont au moins 10 fois meilleures que celles obtenues à l'aide de la technique de Résonance de Plasmons de Surface considérée à ce jour comme la technique de référence en biodétection sans marqueur. Ces premiers résultats, présentant des marges importantes d'amélioration, contribuent à démontrer que les capteurs à base de microrésonateurs optiques sont des candidats potentiels très prometteurs pour la détection de très faibles concentrations de biomolécules pour l'analyse biochimique.
56

MEMS à veine fluidique intégrée pour la caractérisation et la pesée d'échantillons liquides / MEMS with an embedded microchannel for characterization and weighing of fluidic samples

Hadji, Céline 04 November 2016 (has links)
Les systèmes MEMS et NEMS permettent, par résonance mécanique, des mesures de masse avec une sensibilité et une résolution propices à la caractérisation d'objets de taille micro- et nanométrique. Ces dispositifs, adaptés à une intégration dans des systèmes d'analyse miniatures plus complexes, sont d'intérêt pour la recherche biomédicale et la détection de particules. Toutefois la caractérisation en milieu liquide reste à ce jour délicate, principalement à cause de phénomènes dissipatifs associés à la mise en mouvement du fluide environnant le dispositif vibrant.Afin de lever ce verrou, l’équipe au sein de laquelle s’est déroulée cette thèse a développé des MEMS fluidiques sous forme de plaques minces mises en vibration dans leur plan de manière à limiter l'excitation du fluide environnant. Chaque plaque comporte un canal microfluidique permettant la circulation d'un liquide dont la masse moyenne est précisément déterminée par la fréquence de résonance du système. A terme, l'ambition de ces systèmes est de parvenir à révéler, par un décalage en fréquence, le passage au sein de la plaque vibrante d’une particule unique transportée par le liquide.Deux objectifs ont été atteints dans le cadre de cette thèse. D'une part, le comportement de ces structures en présence de divers liquides a été finement caractérisé ce qui a permis d’évaluer leurs performances réelles en fonction des conditions d'excitation. La résolution mesurée pour ces capteurs est de l’ordre de quelques g.L-1, pour une sensibilité d’environ 100 Hz.(g.L-1)-1.D'autre part, une nouvelle génération de capteurs aux caractéristiques innovantes a été conçue en vue d’abaisser le seuil de détection en diminuant la masse des résonateurs et en améliorant le bruit en fréquence.Ce manuscrit sera articulé autour de quatre chapitres. Le premier propose un état de l’art des techniques existantes pour la caractérisation de particules en fluide, et détaille ensuite les solutions MEMS et NEMS développées à cette fin dans la littérature. Le second chapitre livre les résultats issus de la caractérisation d’une première génération de MEMS fluidiques. Le troisième décrit les observations et mesures réalises, et propose des perspectives d’amélioration de ces composants ainsi que de leur protocole de caractérisation. Enfin, on présente dans le dernier chapitre une nouvelle génération de NEMS conçue et fabriquée au cours de cette thèse ; pour finir sont discutés les choix réalisés et les perspectives d’évolution attendues pour ces composants. / MEMS and NEMS allow sensitive and precise mass detection consistent with micro- and bio- objects analysis. These systems are promising for biomedical research and particle metrology, and can be easily integrated in miniaturized multifunctional systems. Thererfore, characterization in liquid media remains tricky due to viscous dissipation consequent to the movement induced in the fluidic environment.In order to overcome this technological lock, our laboratory previously designed and fabricated specific MEMS devices for fluidic analysis; these thin plate resonators with and embedded microchannel are actuated in liquid media, with four capacitive electrodes providing both actuation and detection. The circulating fluid mass can be precisely measured by monitoring the device’s resonant frequency. The long-term objective is to be able to detect and weigh one single particle transported by the fluid.Two main objectives were fulfilled during these three years. First, the MEMS behaviour in presence of various liquids was evaluated, providing a fine-grained analysis of their performances as mass sensors. The measured resolution of our sensors is about a few g.L-1 with a sensitivity of 100 Hz.(g.m-3)-1.Meanwhile, a new generation of NEMS sensors with innovative features was designed; the objective is to decrease the effective mass and reduce the frequency noise, both for a better mass resolution.This thesis includes four chapters. The first one consists in a review of the existing techniques for particles characterization in fluid as well as MEMS and NEMS solutions for particles metrology described in the litterature. The second part of the manuscript presents the results of the experimental characterizations carried out on the first generation of sensors. The third chapter gathers the conclusions of these measurements and gives an outlook on possible improvements on both the design and the characterization of the sensors. At last, the fourth part describes the new generation of devices and discusses their characteristics in terms of expected resolution and applications.
57

Electrodes en diamant pour la fabrication de microsystèmes électrochimiques pour applications biologiques / Diamond based electrodes for the design of electrochemical microsystems for biological applications

Kiran, Raphael 21 September 2012 (has links)
Le diamant dopé bore (BDD) est un matériau extrêmement prometteur pour applications biomédicales par son unique combinaison de propriétés. Cette thèse a visé le développement de nouvelles structures de micro-électrodes en BDD et l'étude de leur intérêt et leurs performances pour des applications électroanalytiques et électrophysiologiques. En dépit de leurs propriétés électroanalytiques très supérieures à d'autres matériaux d'électrodes plus conventionnels, les électrodes BDD sont sujettes au «fouling», i.e. l'apparition d'un film à la surface du diamant qui réduit la réactivité électrochimique. Ceci est très compromettant dans des milieux complexes comme l'urine, les eaux stagnantes, des boissons, le plasma sanguin etc. Ici, un nouveau traitement d'activation a été développé pour nettoyer la surface des électrodes et recouvrir leur réactivité initiale, donc il permet leur usage pour de longues périodes d'enregistrement sans dégradation du signal. Ceci permet l'usage de ce type d'électrodes, pour des domaines d'applications, pour le suivi continu d'analytes, sans entretien spécifique, en solutions complexes. La grande originalité de ces techniques d'activation est qu'elle peut être menée directement dans l'analyte lui-même. En comparaison avec leurs équivalents en macro-électrodes, les microélectrodes permettent d'obtenir de plus grandes sensibilités, des courants résiduels moindre, des pertes ohmiques moindres, et donc des rapports signal à bruit meilleurs. Un procédé robuste et fiable a été optimisé pour la fabrication de réseaux de microélectrodes (MEA MicroElectrode Arrays) et d'ultra micro-électrodes, permettant par lithographie sur 4 pouces d'offrir une large flexibilité de fabrication. Par exemple, parmi d'autres prototypes, des microélectrodes BDD ont été utilisées pour applications de biocapteurs pour quantifier l'acide urique en temps quasi-réel. Bien que le diamant possède une très bonne biocompatibilité et des propriétés électrochimiques excellentes, la faible relative capacité de double couche limite leur application pour des applications électrophysiologiques. Des procédés de nanostructuration ont ainsi été mis au point pour accroitre les limites d'injection de charge. Parmi les approches, des procédés hybrides à base de polypyrrole se sont révélés prometteurs, de même que des procédés de gravure pour former de la «nano-herbe» diamant, très intéressantes pour la fabrication de MEAs en BDD. Ces matériaux à fort rapport d'aspect apparaissent comme d'excellents candidats pour applications d'interfaces neuronales et notamment pour la fabrication d'implants rétiniens.STAR / Boron doped diamond (BDD) electrodes are extremely promising in the field of biomedical applications as they exhibit a unique combination of properties. The thesis aims at developing new types of BDD microelectrodes and exploring their interests for electro-analytical and electrophysiological applications. Despite their superior electro-analytical properties, BDD electrodes are prone to fouling, which leads to a loss of electrode reactivity when used in biological fluids such as urine, waste waters, drinks, blood plasma, etc. A novel electrochemical treatment was developed to clean the electrode surface and to retrieve the initial reactivity, thereby enabling the use of BDD electrodes to long periods of measurements without degradation of the signal, thus significantly extending the field of monitoring and surveying applications up to domains where continuous analysis is required. The real novelty of the technique is that it does not require the use of a specific media and thus can be directly performed in the probed (bio-)fluid. Microelectrodes in comparison with macro-electrodes offer higher sensitivity, lower background current, lower ohmic losses and higher signal-to-noise ratio. A robust, high-yield, reliable, and reproducible process for fabricating a thin-film BDD micro and ultra-microelectrode arrays (MEA) was developed using a novel lithographic technique, based on clean room processing on 4 inch substrates, thus offering wide flexibility. For example, among other prototypes, BDD microelectrodes were developed as biosensors to quantify uric acid in human urine in quasi-real time. Although diamond film possesses good biocompatibility and excellent electrochemical properties, the low double-layer capacitance limits its application in electrophysiological applications. Increasing the charge injection limit was investigated by surface modification and nano-structuring. These include the synthesis of hybrid diamond-polypyrrole electrodes and nanograss BDD MEAs. Such high aspect ratio materials appear as excellent candidates for neurointerfacing applications such as for retinal implants.
58

Fonctionnalisation de surfaces hétérogènes or / silice pour l'ancrage sélectif de biomolécules et colloïdes sur biocapteurs LSPR / Surface functionalization of heterogeneous gold / silica substrates for the selective anchoring of biomolecules and colloids onto LSPR biosensors

Palazon, Francisco 18 September 2014 (has links)
La fonctionnalisation chimique de surfaces hétérogènes (fonctionnalisation orthogonale) est une méthode efficace pour diriger l’ancrage de diverses cibles (biomolécules ou nano-objets) sur des zones précises prédéfinies sur un substrat. Ceci est particulièrement intéressant dans le domaine des biocapteurs à plasmons localisés (LSPR) où la transduction ne peut se faire que sur des nano- structures métalliques. L’enjeu est alors d’assurer que les molécules à détecter se fixent spécifiquement sur ces nanostructures et ne s’adsorbent pas sur la surface diélectrique environnante. Dans ce but, nous avons développé dans cette thèse des fonctionnalisations orthogonales de surfaces micro et nanostructurées d’or sur silice à l’aide de divers thiols et silanes. Par rapport à l’état de l’art dans ce domaine, nous avons notamment proposé un protocole en une seule étape et démontré la bonne orthogonalité de ces fonctionnalisations par différentes méthodes de caractérisation chimique de surface (notamment PM-IRRAS, XPS et ToF-SIMS). De plus, ces fonctionnalisations sélectives ont permis l’ancrage spécifique de diverses nanoparticules de latex sur des micro et nanostructures d’or entourées de silice, démontré par MEB. Actuellement, cette méthodologie est en cours d’application dans deux composants photoniques différents où l’on attend d’une part des effets d’exaltation de fluorescence par couplage de nano-antennes et nanobilles marquées et d’autre part un gain en sensibilité d’un biocapteur LSPR pour la détection de différentes biomolécules. / Orthogonal surface chemical functionalization is an efficient method for the selective trapping of different targets (biomolecules or nano-objects) onto predefined regions of a patterned substrate. This is specially interesting in the field of localized surface plasmon resonance (LSPR) biosensors, where transduction only occurs on metallic nanostructures. The aim is thus to ensure that the target molecules can be selectively anchored onto these nanostructures and not adsorbed on the surroun- ding dielectric surface. Thus, we have developped during this PhD different orthogonal functio- nalizations of micro and nanopatterned gold on silica surfaces with thiols and silanes. In regards to the state of the art in this topic, we have proposed a single-step protocol and demonstrated the good orthogonality of such functionalizations by extensive surface chemical characterization including PM-IRRAS, XPS and ToF-SIMS analysis. Furthermore, these functionalizations have been used for the selective anchoring of different latex nanoparticles onto micro and nanopatterns of gold surrounded by silica, as shown by SEM. At the moment, this methodology is being applied in two different photonic devices where we expect on the one hand a coupling between fluorescent nano- beads and plasmonic nano-antennas and, on the other hand, the increase in sensitivity of an LSPR biosensor for detecting different biomolecules.
59

Gold surface nanostructuring for separation and sensing of biomolecules / Nanostructuration des surfaces d'or pour la séparation et la détection de biomolécules

Bedford, Erin 15 November 2016 (has links)
La détection de molécules biologiques dans les environnements physiologiques est essentielle aux soins de santé et la surveillance de l'environnement. Dans ces travaux de thèse, nous étudions et utilisons des surfaces d'or pour la détection de biomolécules, avec l'inclusion de composants nanométriques-spécifiquement, des monocouches auto assemblées (SAMs) d'alcane-thiol et des coquilles d'or nanostructurées-dans l'intention d'améliorer les méthodes de détection biomoléculaire. La fonctionnalisation des surfaces d'or avec des SAMs permet un contrôle de la densité et de l'orientation des biomolécules immobilisées. En utilisant la spectroscopie infrarouge de surface, la spectroscopie de photoelectrons X (XPS) ainsi que la modélisation, utilisant la théorie de la fonctionnelle de la densité (DFT), nous avons trouvé que les SAMs à base de chaînes courtes et de chaînes longues des alcane-thiols ont eu des environnements de l'accroche des atomes de soufre différents. De plus, nous avons trouvé que l'immobilisation et la reconnaissance de protéines varie avec la longueur de la chaîne de SAMs ainsi qu'avec la présence d'un réticulant. Dans la seconde partie des travaux, nous avons synthétisé des coquilles d'or nanostructurées sur des particules magnétiques afin de combiner la séparation magnétique et la détection de biomolécules. Nous avons montré qu'elles pouvaient être utilisés comme substrats pour la spectrométrie Raman exaltée de surface (SERS). Afin d'établir une preuve de concept, nous avons réalisé des tests dans lesquels ces particules ont été utilisées pour détecter l'immobilisation d'oligonucléotides et l'hybridation avec SERS. / Detecting biomolecules in physiological environments is critical to health care and environmental monitoring. In this work, we study and use gold surfaces for biomolecule detection while incorporating nanoscale components—specifically, self-assembled monolayers (SAMs) of alkanethiols and gold nanostructured shells—with the goal of improving biomolecule detection methods. Using SAMs to functionalize gold surfaces can offer control over biomolecule binding density and orientation while still keeping the biomolecules near the sensing surface. Using surface IR spectroscopy, x-ray photoelectron spectroscopy (XPS), and density functional theory (DFT) modeling, we found that SAMs of short-chain and long-chain amine-terminated alkanethiols on gold had different sulphur binding environments. We also found that protein binding and recognition on the two different SAMs varied with SAM chain length and was also influenced by the presence of a cross-linker. In the second part of this work, we synthesized gold nanostructured shells on magnetic particles for combined separation and detection of biomolecules. We demonstrated their use as substrates for surface-enhanced Raman spectroscopy (SERS) As a proof-of-concept, we demonstrated the use of these particles to detect oligonucleotide binding and hybridization with SERS using a Raman-tagged oligonucleotide hairpin probe.
60

Optical detection of (bio)molecules / Détection optique des (bio)molécules

Jia, Kun 10 December 2013 (has links)
Les biocapteurs optiques ont connu une évolution sans précédent au cours des dernières années, principalement en raison de la forte interaction entre la biotechnologie, l’optique et la chimie des matériaux. Dans cette thèse, deux différentes plates-formes de biocapteurs optiques ont été conçues pour la détection sensible et spécifique des biomolécules. Plus précisément, le premier système de détection optique est construit sur la base de la bioluminescence de cellules bactériennes d'Escherichia coli génétiquement modifiées. L’émission de lumière induite par cette interaction peut donc être utilisée pour la détection des substances toxiques. Le second système utilise des nanoparticules de métaux précieux (or et argent) aux propriétés plasmoniques accordables qui permettent de sonder les interactions des biomolécules spécifiques à l'interface nano-bio par la résonance plasmonique de surface (LSPR). Ces nanoparticules ont été obtenues par traitement thermique à haute température d’un film métallique déposé sur du verre à l’aide d’une grille de TEM ou déposé sur une couche de bactéries fixée sur le verre. Après une optimisation appropriée des nanostructures métalliques en termes de morphologie et de fonctionnalisation, une sensibilité élevée et une grande spécificité peuvent être simultanément obtenues avec ces immunocapteurs plasmonique. Ces deux plateformes ont été utilisées pour détecter des pesticides comme le carbofuran et l’atrazine / Optical biosensors have witnessed unprecedented developments over recent years, mainly due to the lively interplay between biotechnology, optical physics and materials chemistry. In this thesis, two different optical biosensing platforms have been designed for sensitive and specific detection of (bio)molecules. Specifically, the first optical detection system is constructed on the basis of bioluminescence derived from engineered Escherichia coli bacterial cells. Upon stressed by the toxic compounds, the bacterial cells produce light via a range of complex biochemical reactions in vivo and the resulted bioluminescent evolution thus can be used for toxicant detection. The bacterial bioluminescent assays are able to provide competitive sensitivity, while they are limited in the specificity. Therefore, the second optical detection platform is built on the localized surface plasmon resonance (LSPR) immunosensors. In this optical biosensor, the noble metal (gold and silver) nanoparticles with tunable plasmonic properties are used as transducer for probing the specific biomolecules interactions occurred in the nano-bio interface. These nanoparticles were obtained after a high temperature thermal treatment of an initially thin-metallic film deposited on a glass substrate through a TEM grid or on a bacteria layer fixed on the glass. After appropriate optimization on metal nanostructures morphology and surface biomodification, the applicable sensitivity and specificity can be both guaranteed in this LSPR immunosensor

Page generated in 0.0839 seconds