• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 491
  • 26
  • 2
  • 1
  • 1
  • Tagged with
  • 538
  • 285
  • 101
  • 100
  • 71
  • 56
  • 45
  • 37
  • 35
  • 34
  • 34
  • 33
  • 33
  • 32
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
411

Dispositivos micromecânicos para caracterização de materiais: instrumentação e análise térmica de polí­meros. / Micromechanical devices for materials characterization: instrumentation and polymer thermal analysis.

Gustavo Marcati Alexandrino Alves 28 November 2018 (has links)
A miniaturização de elementos mecânicos como pontes e vigas por meio de processos de fabricação antes utilizados exclusivamente em microeletrônica, levou ao desenvolvimento de sensores físicos que hoje são onipresentes no dia-dia. Desses elementos, o cantilever, ou viga engastada, é a estrutura mais simples, porém, quando miniaturizado em escala micrométrica, suas propriedades mecânicas como frequência de ressonância e curvatura são muito sensíveis a eventos que ocorrem em sua superfície. Stresses superficiais mínimos, como aqueles gerados pela adsorção de monocamadas na superfície, causam deflexões em uma escala que é facilmente medida com técnicas relativamente simples. Além disso, a frequência de ressonância que é característica da estrutura, é proporcional à mudanças relativas de massa do dispositivo, sendo possível assim, a medida de massa em baixíssimas escalas. Nesse trabalho, estudou-se a utilização do microcantilever como uma plataforma para estudo de materiais, mais especificamente, materiais poliméricos. Depositando-se uma quantidade muito pequena de polímero na superfície de um microcantilever de silício, essa estrutura se curvará devido à diferenças nos coeficientes de expansão térmico entre os materiais. Medindo-se essa curvatura em função da temperatura, é possível detectar eventos térmicos que esse polímero venha sofrer. Esse efeito foi utilizado para estudar como a absorção de água afeta o evento térmico de transição vítrea do polímero PLGA. Observou-se que essa caracterização é muito mais rápida utilizando microcantilever se comparado às técnicas convencionais, além de ser também, muito sensível às variações de quantidade de água. Para a realização desses estudos, foi desenvolvido um sistema de medidas que utiliza pick-up de CDROM, retirada de um leitor comum, para medir a deflexão dos dispositivos. Esse tipo de arranjo é capaz de medir diferenças de nanômetros de deslocamento com um custo mínimo. Explorou-se a capacidade de controle de temperatura e leitura de deslocamento aplicando-se a técnica de modulação de temperatura nos estudos de eventos térmicos do PLGA. Observou-se que a modulação de temperatura é aplicável a esse tipo de medida e resultados muito semelhantes àqueles obtidos com técnicas convencionais são obtidos com uma quantidade muito menor de material. Como essas medidas foram realizadas utilizando sensores comerciais, realizamos a construção de matrizes de cantileveres no laboratório para demonstrar completo desenvolvimento desse tipo de plataforma de sensor. Empregando um polímero fotossensível relativamente novo para o desenvolvimento dessas matrizes, às utilizamos para caracterizações das propriedades mecânicas desse material. / The miniaturization of mechanical elements such as bridges or beams employing fabrication process previously used exclusively in microelectronics, resulted in the development of ubiquous physical sensors used today. The cantilever, or single supported beam is the most simple of these structures, but, when miniaturizated in the micrometer scale, the properties of the structure are highly dependent on events that takes place in its surface. Minimal superficial stresses like the ones generated by the adsorption of monolayers causes deflection of the structure in a scale that are easily measured by simple techniques. Moreover, the resonant frequency is highly dependent on relative mass changes of the device, making it a very sensitive microbalance. In this work, it was studied the application of microcantilevers as a platform for the study of materials properties, more specifically thermal analysis of polymeric material. When a very small quanitity of polymer is deposited in the surface of a silicon microcantilever, the structure will bend due to the mismatch of thermal expansion between the materials. Measuring the beam curvature in function of temperature enables the detection of thermal events suffered by the polymer. This effect was used to measure how the water absorption by the polymer affect the glass transition thermal event of the PLGA polymer. It was observed that this technique is faster if compared to traditional thermal chracterization techniques. To enable those characterizations, it was developed a measurement systems based on CDROM pick-up that can read the nanometer scale cantilever deflection with a minimum cost. The full capabilities of this system was then used to apply temperature modulation to the thermal studies of PLGA, we observed similar responses if compared to traditional approaches but with much less material use. Comercial sensors were used on these characterization, but, to present complet domain of cantilever sensor platform, we developed a fabrication process of polymeric cantilever array at the lab. These arrays were then used to extract mechanical information about the polymer used in its construction.
412

Hidroxiapatita associada a gentamicina: um estudo da influencia da gelatina no meio da precipitação e do processo de secagem na inibição do crescimento bacteriano

Moreira, Jussany Maria de Barros 27 October 2009 (has links)
Made available in DSpace on 2017-07-24T19:38:01Z (GMT). No. of bitstreams: 1 dissertacao - parte liberada.pdf: 1154549 bytes, checksum: d7a9809bce797a5c245ab7132bbf659b (MD5) Previous issue date: 2009-10-27 / Several studies have demonstrated that hydroxyapatite outstands amongst bioceramics, since it presents excellent biocompatibility with human bone mineral phase, stoichiometric formula (Ca10(PO4)6(OH)2 ), with Ca/P ratio equal 1,67. It also has the capability of bonding chemically with the tissue, which makes it a bioactive material. Despite the structure and properties of bone tissue representing one of the major fields of study, nowadays the interest is in the possibility of incorporating drugs to such biomaterials. In this work, HA and HA:Gel composites were prepared through the precipitation method, which consisted of the mixture of a Ca(OH)2 (2 mol.L-1 ) solution to a H3PO4 (1,2 mol.L-1) solution, in constant agitation, heating and pH control. The precipitate obtained were put to age for a day and later one part of them was dried in oven at 100ºC and another part lyophilized for 48 hours. Powders were then sieved, calcined and had gentamicin sulfate (C21H43N5O7.2,5H2SO4) added to them in 0,25, 0,5, 1,0 e 2,0% in mass concentrations. These powders were characterized through: infrared absorption spectroscopy, X-ray diffractometry, scanning electronic microscopy (SEM), transmission electronic microscopy (TEM), granulometric analyses, specific superficial area by the BET method, differential thermal analysis (DTA) and thermogravimetry (TG). In all samples analyzed, the mineral part was characterized as carbonated hydroxyapatite. It was observed that the morphology and crystal size are influenced by the drying method and gelatin addition. The Ca/P ratio found was above the desired one for the stoichiometric hydroxyapatite. Through the SEM and TEM analysis, the presence of agglomerates, characteristic to apatites was noticed. The samples microbiological activity evaluation with saliva, with 0,5, 1,0 e 2,0% gentamicin sulfate in mass resulted in UFC equal zero, and samples with 0,25% of the same drug in mass presented sharp decrease in the colonies development, however, only the HA:Gel dried in oven, the UFC remained equal zero. Microbiological analysis results confirm the antibiotic inhibitor action when impregnating the hydroxyapatite. / Estudos demonstram que a hidroxiapatita, vem se destacando entre as biocerâmicas, pois apresenta excelente biocompatibilidade com a fase mineral do osso humano, de fórmula estequiométrica (Ca10(PO4)6(OH)2 ), com razão Ca/P igual a 1,67. Tem a capacidade de unir-se quimicamente com o tecido, o que a torna um material bioativo. Apesar da estrutura e propriedades do tecido ósseo representar um dos maiores campos de estudo, na atualidade o interesse está na possibilidade de incorporação de drogas a esses biomateriais. Neste trabalho foram preparados compósitos de HA e HA:Gel pelo método da precipitação, que consistiu na mistura de uma solução de Ca(OH)2 (2 mol.L-1) com uma solução de H3PO4 (1,2 mol.L-1), sob agitação constante,aquecimento e controle de pH. Os precipitados obtidos foram envelhecidos por um dia e posteriormente uma parte deles foi seco em estufa à 100ºC e a outra parte foi liofilizada por 48 horas. Os pós foram peneirados, calcinados e em seguida adicionados sulfato de gentamicina (C21H43N5O7.2,5H2SO4) em concentrações de 0,25, 0,5, 1,0 e 2,0% em massa. Os pós obtidos foram caracterizados por: espectroscopia de absorção na região do infravermelho; difratometria de Raios X; microscopia eletrônica de varredura (MEV-EDS), microscopia eletrônica de transmissão (MET), análises granulométricas, área superficial específica pelo método BET; análise térmica diferencial (DTA) e termogravimetria (TG). Em todas as amostras analisadas a parte mineral foi caracterizada como hidroxiapatita carbonatada. Foi verificado que a morfologia e o tamanho dos cristais são influenciados pelo tipo de secagem e pela adição de gelatina. A razão Ca/P encontrada foi superior a desejada para hidroxiapatita estequiométrica. Através das análises de MEV e MET observa-se a presença de aglomerados, característicos as apatitas. A avaliação da atividade microbiológica das amostras frente à saliva, com impregnação de 0,5, 1,0 e 2,0% em massa de sulfato de gentamicina obteve-se a contagem de Unidade Formadora de Colônia (UFC) igual a zero, sendo que nas amostras com 0,25% em massa do mesmo antibiótico houve uma grande diminuição no crescimento de colônias, porém apenas na amostra de HA:Gel seca em estufa, a contagem de UFC, permaneceu igual a zero. Os resultados das análises microbiológicas comprovam a ação inibidora do antibiótico quando impregnados a hidroxiapatita.
413

SÍNTESE E CARACTERIZAÇÃO DE ORTOFOSFATOS DE CÁLCIO DOPADOS COM NIÓBIO (V) POR MEIO DA ROTA HIDROTÉRMICA E AVALIAÇÃO DE CITOCOMPATIBILIDADE

Simomukay, Elton 05 September 2013 (has links)
Made available in DSpace on 2017-07-24T19:38:14Z (GMT). No. of bitstreams: 1 Elton Simomukay.pdf: 7491521 bytes, checksum: 371fd9b9e8a72e2e30452ec70f1b869b (MD5) Previous issue date: 2013-09-05 / This study aimed to obtain potential biomaterials synthesized through hydrothermal reaction between monohydrated calcium ethanoate and the anhydrous ammonium monophosphate with addition of 57.6, 288 and 576 ppm niobium ion precursor (V), the ammonium niobate oxo-tris (oxalate) niobium complex and trihydrated hydrogen that so far has not been often used in biomaterial synthesis. In such an area of increasing innovations, this addition enables to obtain calcium orthophosphates with new perspectives in the biomaterial field in relation to the characteristics of morphological and structural biocompatibility. The synthesis was carried out at temperatures ranging from 100 to 200°C for 24 hours with the use of diaminomethanal to control the precipitation pH and the 2-hydroxy-1,2,3 propano tricarboxylic monohydrated as a regulator of the synthesis initial pH and as a chelating agent for the metallic ions. X-ray diffraction (XRD) was used to characterize the phases formed in the samples, and these phases were confirmed through the Fourier transform infrared spectroscopy (FT-IR) and Raman spepctroscopy (RS). The scanning electronic microscopy coupled with X-ray dispersive energy (SEM-XDE) and, transmission electronic microscopy (TEM) were employed to visualize the format of the particles and map the elements present while the laser diffraction granulometric analysis (GDL) and dynamic light scattering analysis (DLS) characterized the distribution of particle sizes. Thermal analysis (TG and DTA) were carried out to verify the thermal behavior and the chemical composition was determined through X-ray fluorescence (XRF). The sample roughness was evaluated through the atomic force microscopy technique (AFM). These materials were submitted to toxicity tests through tests with the Tripan blue dye, MTT reduction measurement and, neutral red dye uptake measurement in order to characterize it initially as a biomaterial. Results obtained in this study enable to conclude that the predominant phase in the samples is the hydroxyapatite, Ca5(PO4)3OH. The increase in the addition of niobium ions precursor (V) from 228 ppm on provokes the appearance of minority phases of niobium compounds and the same precursor affects the morphology and growth of particles originating flower like agglomerates also known as self-structured, and these agglomerates are mainly round with micrometric dimensions formed by nanometric crystallites. The samples kept thermal stability up to 1000°C without forming other calcium orthophosphates besides the hydroxyapatite. The presence of niobium ions (V) was identified in all added samples. The citoxicity of samples could be confirmed by the results of in vitro tests which presented reasonable results enabling other biocompatibiliity characterizations to be carried out to define the use of the samples obtained as biomaterial. / Este trabalho teve como objetivo a obtenção de possíveis biomateriais sintetizados pela reação hidrotérmica entre o etanoato de cálcio monohidratado e o monofosfato de amônio anidro aditivados com 57.6, 288 e 576 ppm de um precursor de íons nióbio (V), o complexo de nióbio oxo-tris (oxalato) niobato de amônio e hidrogênio trihidratado que até o momento é pouco empregado na síntese de biomateriais. Em uma área de crescentes inovações, esta aditivação possibilita a obtenção de ortofosfatos de cálcio com novas perspectivas no campo dos biomateriais em relação às características de biocompatibilidade, morfológicas e estruturais.A síntese foi realizada com temperaturas variando de 100 a 200 °C durante 24 horas com o emprego do diaminometanal para controle do pH de precipitação e do ácido 2-hidroxi-1,2,3 propanotricarboxílico monohidratado como regulador do pH inicial da síntese e como agente quelante para os íons metálicos.Para a caracterização das fases formadas nas amostras obtidas foi utilizada a técnica de difração de raios X (DRX) sendo estas fases confirmadas pelas técnicas espectroscópicas de espectroscopia de absorção na região do infravermelho por transformada de Fourier (IV-TF) e espectroscopia Raman.As técnicas de microscopia eletrônica de varredura acoplada com detector de energia dispersiva de raios X (MEV-EDX) e, de microscopia eletrônica de transmissão (MET) foram empregadas para visualização do formato das partículas e mapeamento de elementos presentes enquanto as técnicas de análise granulométrica por difração de laser (DL) e, de análise por espalhamento dinâmico de luz (EDL) caracterizaram a distribuição do tamanho de partículas. Análises térmicas (TG e ATD) foram realizadas para verificar o comportamento térmico e a composição química foi determinada através da fluorescência de raios X (FRX).A rugosidade da amostras foi avaliada através da técnica de microscopia de força atômica (AFM).Estes materiais foram submetidos a testes de citotoxicidade através dos ensaios do emprego do corante azul de Tripan, medida da redução do MTT e, medida da captação do corante vermelho neutro a fim de inicialmente caracterizá-lo como um biomaterial.Os resultados obtidos neste estudo permitem concluir que a fase predominante nas amostras é a hidroxiapatita, Ca5(PO4)3OH.O aumento da aditivação do precursor de íons nióbio (V) a partir de 288 ppm provoca o surgimento de fases minoritárias de compostos de nióbio e o mesmo precursor afeta a morfologia e o crescimento das partículas originando aglomerados do tipo flower também conhecidas como morfologias auto-estruturadas sendo estes aglomerados predominantemente arredondados com dimensões micrométricas formados por cristalitos nanométricos.As amostras mantiveram estabilidade térmica até 1000 °C sem a formação de outros ortofosfatos de cálcio além da hidroxiapatita.A presença dos íons nióbio (V) foram identificados em todas as amostras aditivadas. A citotoxicidade das amostras pode ser comprovada pelos resultados nos ensaios in-vitro que apresentaram resultados aceitáveis para a possibilidade de realização de outras caracterizações de biocompatibilidade de modo a definir o emprego das amostras obtidas como biomateriais.
414

Expressão das proteínas citoesqueléticas actina e tubulina em células osteogênicas cultivadas sobre vidro e vitrocerâmica bioativos / Expression of the cytoskeletal proteins actin and tubulin in osteogenic cells cultured on bioactive glass-based surfaces

Carolina Scanavez Martins 03 August 2012 (has links)
A implantação de materiais vítreos e vitrocerâmicos bioativos representa estratégia terapêutica importante para se promover a formação de matriz extracelular mineralizada em defeitos ósseos críticos. Quando expostos a fluidos biológicos, estes biomateriais sofrem alterações químicas e topográficas de superfície que afetam as interações de células com sua superfície, reduzindo o espraiamento celular e alterando o padrão de marcação de proteínas do citoesqueleto. O objetivo deste estudo foi avaliar se as alterações no padrão de marcação para as proteínas citoesqueléticas actina e tubulina observadas in vitro em células osteogênicas sobre superfícies do vidro Bioglass® 45S5 e da vitrocerâmica Biosilicato®, são decorrentes de redução quantitativa na expressão do RNAm e das proteínas correspondentes. Células osteogênicas foram obtidas a partir da digestão enzimática de calvárias de ratos Wistar recémnascidos e plaqueadas sobre superfícies de Bioglass® 45S5, Biosilicato® e borosilicato (controle bioinerte) para a avaliação dos seguintes parâmetros: 1) detecção de actina e tubulina por microscopia de fluorescência; 2) expressão de RNAm para actina e tubulina por reação em cadeia da polimerase em tempo real (Real time PCR); 3) quantificação de actina e tubulina por ensaio imunoenzimático direto (ELISA), e 4) análise da morfologia celular por microscopia eletrônica de varredura (MEV). Aos 3 e 7 dias, células crescidas sobre borosilicato exibiam padrões de marcação para actina e tubulina típicos de células aderidas e espraiadas sobre substratos planos in vitro, enquanto que sobre Bioglass® 45S5 e Biosilicato® as células apresentavam áreas circulares destituídas de marcação para essas proteínas. Nos mesmos períodos, culturas crescidas sobre os materiais bioativos apresentavam alterações significantes da expressão de RNAm para actina e tubulina, embora fossem observadas apenas discretas variações na quantidade das proteínas correspondentes em relação ao borosilicato. Além disso, apenas para culturas crescidas sobre borosilicato observava-se correlação positiva entre RNAm e proteína e correspondência entre as observações por epifluorescência e os dados quantitativos. Aos 3 dias, imagens de MEV revelaram células aderidas e espraiadas sobre os materiais bioativos, parcial ou totalmente recobertas por acúmulos de material de aspecto semelhante ao da topografia do substrato, por vezes impedindo a visualização dos limites celulares. Com base nos resultados obtidos, conclui-se que as superfícies bioativas de Bioglass® 45S5 e Biosilicato® afetam a expressão de RNAm para actina e tubulina, mas não de proteína. Assim, as alterações nos padrões de marcação por fluorescência para essas proteínas devem ser atribuídas, pelo menos em parte, a acúmulos de material sobre as células, possivelmente decorrentes das reações de superfície a que estão submetidos Bioglass® 45S5 e Biosilicato® quando em contato com fluidos biológicos. / Bioactive glasses and glass-ceramics have been successfully applied in various therapeutic strategies to promote the formation of mineralized matrix in bone defects. The exposure of these materials to biological fluids results in chemical and topographical modifications that may affect the interactions of cells with the biomaterial surface, with potential effects on cytoskeletal protein expression and/or organization and cell spreading. The aim of the present study was to evaluate whether changes in the labelling pattern for the cytoskeletal proteins actin and tubulin in osteogenic cells cultured on bioactive Bioglass® 45S5 and Biosilicate® are due to altered mRNA and protein expression levels. Osteogenic cells were obtained by enzymatic digestion of newborn Wistar rat calvarial bone and plated on Bioglass® 45S5, Biosilicate® and borosilicate (bioinert control) for periods of up to 7 days. The following parameters were assayed: i) qualitative epifluorescence analysis of actin and tubulin distribution; ii) quantitative mRNA expression for actin and tubulin by real time polymerase chain reaction (real time PCR); iii) quantitative actin and tubulin expression by enzymelinked immunoabsorbent assay (ELISA), and iv) qualitative analysis of cell morphology by scanning electron microscopy (SEM). At days 3 and 7, cells grown on borosilicate showed typical actin and tubulin labeling patterns of adherent and spread cells on flat, rigid substrates, whereas those on Bioglass® 45S5 and Biosilicate® showed dark areas devoid of fluorescent signals for the cytoskeletal proteins. At the same time points, cultures grown on the bioactive materials showed significant changes in mRNA expression for actin and tubulin, although only slight differences in the amount of actin and tubulin were detected compared with borosilicate. Moreover, a positive correlation between mRNA and protein expression levels as well as a correspondence between epifluorescence imaging and the quantitative data were only detected for cultures grown on borosilicate. SEM analysis revealed that cells cultured on bioactive surfaces were partly or totally covered with material accumulations, whose characteristics resembled the ones for the substrate topography, and which, in some cases, prevented the visualization of the cell limits. In conclusion, Bioglass® 45S5 and Biosilicate® affect actin and tubulin mRNA levels, but not the corresponding protein expression, in osteogenic cell cultures. Thus, the observed changes in the labeling pattern for these proteins should be attributed, at least in part, to the accumulation of materials on the cell surface, likely due to substrate reactions that take place on Bioglass® 45S5 and Biosilicate® when exposed to the cell culture medium.
415

Desenvolvimento de membranas de látex natural para aplicações médicas / Development of natural rubber latex membranes for medical applications

Herculano, Rondinelli Donizetti 28 April 2009 (has links)
O objetivo principal deste trabalho consiste na incorporação de substâncias de interesse biológico (fármacos) em filmes de látex natural (NRL). Assim, estudou-se a liberação destes, visando no futuro usar estes filmes como membrana oclusiva e como sistema de liberação controlada (SLC) de substâncias para aplicações odontológicas e ortopédicas, que envolvem a cicatrização óssea guiada. Estudamos o comportamento do SLC utilizando albumina de soro bovina (BSA) como modelo de proteína e o metronidazol (MTZ) como modelo de antibiótico. Diferentes tratamentos térmicos foram aplicados durante a confecção dos filmes a fim de gerar diferentes porosidades e com isso estudar-se a taxa de liberação destes fármacos. A taxa de liberação dos fármacos foi monitorada e quantificada utilizando o método de Lowry e o método UVVIS. Microscopia Eletrônica de Varredura (MEV) e a Microscopia de Força Atômica (AFM) determinaram a morfologia do SLC. Em outro parte deste trabalho desenvolvemos um sistema para liberação do óxido nítrico (NO) agregando-se o complexo (FeDETC) ao NRL, pois esta substância atua como spin trapp para este radical. A taxa de liberação do NO pelo sistema NRL-FeDETC-NO foi caracterizada pela Ressonância Paramagnética Eletrônica (EPR). A escolha destas substâncias para este estudo deve-se pelo fato que auxiliam no processo de regeneração óssea (MTZ e NO). Entretanto, a BSA foi utilizada porque possui peso molecular da mesma magnitude e é mais barata que as proteínas morfogenéticas ósseas (BMP). As BMP´s são excelentes estimuladores do crescimento ósseo. / In this work, we have tested Natural Rubber Latex (NRL) as an occlusive membrane for GBR with promising results. One possible way to accelerate bone regeneration would be to incorporate proteins bone morphogenetic protein (BMPs) in NRL. BMPs have strong bone-inductive activity. However since bone healing takes place in weeks to months, it is important that BMPs are released in these time scales. Instead of using BMPs, in our study we used BSA that has similar molecular weight however is less expensive. Moreover, we also employed the metronidazole (MTZ) and nitric oxide (NO) as drug delivery model. MTZ is a used antibiotic for treatment of infections in the skin, fabrics and bones. Initially, we study the BSA delivery system behavior and MTZ delivery system using different thermal treatments during the membranes polymerization. The thermal treatments control the size of the pores of the SLC and release rate of the BSA and MTZ. These membranes were characterized by Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), as well as the Lowry Method to measure the BSA release. Finally, we propose a NO delivery system made of a spin trap (iron(II)-diethyldithiocarbamate complex, FeDETC) encapsulated in a NRL matrix. NO is an early mediator of the increase in bone formation. NO delivery system presents high stability by Electron Paramagnetic Resonance. The results indicate that natural rubber latex could be used in the future as an active membrane for accelerated bone healing.
416

Redução da biocarga e garantia de esterilidade em implantes mamários de silicone / Bioburden reduction and sterility assurance in silicone gel breast implants

Santos, Glaucia Cristina Mello 16 December 2009 (has links)
Os implantes mamários de silicone constituem-se em biomateriais os quais têm sido amplamente utilizados em cirurgias para reconstituição da mama após ocorrência de câncer, acidentes, correção do tamanho dos seios quando há uma diferença de volume entre eles, ou até mesmo, para o aumento do tamanho da mama por motivos estéticos. Com o intuito de conferir segurança em sua aplicação, intimamente ligada à saúde dos pacientes, grande atenção tem sido dada aos processos de esterilização aplicados a biomateriais. Ao avaliar o processo produtivo de implantes mamários de silicone, um dos processos de esterilização mais comumente empregados é o calor seco, que necessita de elevadas temperaturas por longo tempo para o sucesso da esterilização. A exposição do implante a tais condições potencialmente pode ocasionar alterações de suas características. De outro lado, uma etapa preliminar do processo produtivo do implante é a vulcanização, que consiste no aquecimento do implante a temperaturas da ordem de 165 ± 5°C por aproximadamente 9 horas. Considerando tempo e temperatura empregados nesta etapa, o objetivo deste estudo foi avaliar a carga microbiana dos implantes mamários de silicone antes do processo de vulcanização, assim como o decaimento da carga microbiana neste processo e também confirmar a esterilidade do gel contido internamente à membrana. Desta forma, foi possível observar que o nível de contaminação microbiana dos implantes gelatinosos é relativamente baixo e que a vulcanização foi um processo que possibilitou a inativação de até 108 esporos, a concentração de esporos mais alta utilizada no estudo. Os resultados mostraram que a vulcanização possibilitou não só a redução da carga microbiana, mas também consiste em mecanismo para garantir a esterilidade do gel interno ao produto. Desta forma, o processo esterilizante final teve como contribuição elevar o Nível de Garantia de Esterilidade (SAL ou Sterility Assurance Level), condição interessante ao se considerar a tendência de adoção da liberação paramétrica, assim como o conceito de validação combinado bioburden/indicador biológico em vez de sobre-morte. Avaliação complementar foi feita ao quantificar endotoxina nos implantes antes e após o processo de esterilização (calor seco e óxido de etileno), verificando-se que os processos considerados não alteram significativamente a quantidade de endotoxina. Ainda assim, em todas as situações foram obtidos níveis aceitáveis, conforme USP 31. / Silicone breast implants consist of biomaterials widely used in breast reconstitution surgeries after the occurrence of cancer, accidents, breast size correction (in case of different volume between both breasts)or in mammary augmentation for esthetic reasons. With a view to confer security in its application, directly related to patients health, great attention has been given to sterilization processes applied to biomaterials. Among these, dry heat is one of the most often employed. For a successful sterilization, it requires high temperatures for a long period, what may give rise to alteration of the implant characteristics. On the other hand, a preliminary stage of the implant production process is vulcanization, which consists of heating the implant to 165 ± 5°C for approximately 9 hours. Taking into account the time and temperature used in this stage, the aim of this work was to evaluate the bioburden of silicone breast implants prior to the vulcanization process and the decline in bioburden due to this process, and to confirm the sterility of the gel contained in the membrane. This study led us to the conclusion that the level of microbial contamination of gel implants is relatively low, and that vulcanization allowed for the inactivation of up to 100 million spores, the highest concentration of spores used in this study. The results obtained showed that vulcanization enabled not only the reduction of the microbial load, but also guaranteed the sterility of the gel inside the product. Thus, the final sterilizing process contributed to an increase in the Sterility Assurance Level, an interesting phenomenon if we consider the tendency toward adoption of parametric release and the concept of a combined validation bioburden/biological indicator rather than overkill. Complement evaluation was made measuring endotoxins in the implants before and after the sterilization process (dry heat and ethylene oxide), verifying that the considered processes do not modify the amount of endotoxin significantly, as expectation. Still thus, in all the situations had been gotten acceptable levels, as USP 31.
417

Dispositivos micromecânicos para caracterização de materiais: instrumentação e análise térmica de polí­meros. / Micromechanical devices for materials characterization: instrumentation and polymer thermal analysis.

Alves, Gustavo Marcati Alexandrino 28 November 2018 (has links)
A miniaturização de elementos mecânicos como pontes e vigas por meio de processos de fabricação antes utilizados exclusivamente em microeletrônica, levou ao desenvolvimento de sensores físicos que hoje são onipresentes no dia-dia. Desses elementos, o cantilever, ou viga engastada, é a estrutura mais simples, porém, quando miniaturizado em escala micrométrica, suas propriedades mecânicas como frequência de ressonância e curvatura são muito sensíveis a eventos que ocorrem em sua superfície. Stresses superficiais mínimos, como aqueles gerados pela adsorção de monocamadas na superfície, causam deflexões em uma escala que é facilmente medida com técnicas relativamente simples. Além disso, a frequência de ressonância que é característica da estrutura, é proporcional à mudanças relativas de massa do dispositivo, sendo possível assim, a medida de massa em baixíssimas escalas. Nesse trabalho, estudou-se a utilização do microcantilever como uma plataforma para estudo de materiais, mais especificamente, materiais poliméricos. Depositando-se uma quantidade muito pequena de polímero na superfície de um microcantilever de silício, essa estrutura se curvará devido à diferenças nos coeficientes de expansão térmico entre os materiais. Medindo-se essa curvatura em função da temperatura, é possível detectar eventos térmicos que esse polímero venha sofrer. Esse efeito foi utilizado para estudar como a absorção de água afeta o evento térmico de transição vítrea do polímero PLGA. Observou-se que essa caracterização é muito mais rápida utilizando microcantilever se comparado às técnicas convencionais, além de ser também, muito sensível às variações de quantidade de água. Para a realização desses estudos, foi desenvolvido um sistema de medidas que utiliza pick-up de CDROM, retirada de um leitor comum, para medir a deflexão dos dispositivos. Esse tipo de arranjo é capaz de medir diferenças de nanômetros de deslocamento com um custo mínimo. Explorou-se a capacidade de controle de temperatura e leitura de deslocamento aplicando-se a técnica de modulação de temperatura nos estudos de eventos térmicos do PLGA. Observou-se que a modulação de temperatura é aplicável a esse tipo de medida e resultados muito semelhantes àqueles obtidos com técnicas convencionais são obtidos com uma quantidade muito menor de material. Como essas medidas foram realizadas utilizando sensores comerciais, realizamos a construção de matrizes de cantileveres no laboratório para demonstrar completo desenvolvimento desse tipo de plataforma de sensor. Empregando um polímero fotossensível relativamente novo para o desenvolvimento dessas matrizes, às utilizamos para caracterizações das propriedades mecânicas desse material. / The miniaturization of mechanical elements such as bridges or beams employing fabrication process previously used exclusively in microelectronics, resulted in the development of ubiquous physical sensors used today. The cantilever, or single supported beam is the most simple of these structures, but, when miniaturizated in the micrometer scale, the properties of the structure are highly dependent on events that takes place in its surface. Minimal superficial stresses like the ones generated by the adsorption of monolayers causes deflection of the structure in a scale that are easily measured by simple techniques. Moreover, the resonant frequency is highly dependent on relative mass changes of the device, making it a very sensitive microbalance. In this work, it was studied the application of microcantilevers as a platform for the study of materials properties, more specifically thermal analysis of polymeric material. When a very small quanitity of polymer is deposited in the surface of a silicon microcantilever, the structure will bend due to the mismatch of thermal expansion between the materials. Measuring the beam curvature in function of temperature enables the detection of thermal events suffered by the polymer. This effect was used to measure how the water absorption by the polymer affect the glass transition thermal event of the PLGA polymer. It was observed that this technique is faster if compared to traditional thermal chracterization techniques. To enable those characterizations, it was developed a measurement systems based on CDROM pick-up that can read the nanometer scale cantilever deflection with a minimum cost. The full capabilities of this system was then used to apply temperature modulation to the thermal studies of PLGA, we observed similar responses if compared to traditional approaches but with much less material use. Comercial sensors were used on these characterization, but, to present complet domain of cantilever sensor platform, we developed a fabrication process of polymeric cantilever array at the lab. These arrays were then used to extract mechanical information about the polymer used in its construction.
418

Redução da biocarga e garantia de esterilidade em implantes mamários de silicone / Bioburden reduction and sterility assurance in silicone gel breast implants

Glaucia Cristina Mello Santos 16 December 2009 (has links)
Os implantes mamários de silicone constituem-se em biomateriais os quais têm sido amplamente utilizados em cirurgias para reconstituição da mama após ocorrência de câncer, acidentes, correção do tamanho dos seios quando há uma diferença de volume entre eles, ou até mesmo, para o aumento do tamanho da mama por motivos estéticos. Com o intuito de conferir segurança em sua aplicação, intimamente ligada à saúde dos pacientes, grande atenção tem sido dada aos processos de esterilização aplicados a biomateriais. Ao avaliar o processo produtivo de implantes mamários de silicone, um dos processos de esterilização mais comumente empregados é o calor seco, que necessita de elevadas temperaturas por longo tempo para o sucesso da esterilização. A exposição do implante a tais condições potencialmente pode ocasionar alterações de suas características. De outro lado, uma etapa preliminar do processo produtivo do implante é a vulcanização, que consiste no aquecimento do implante a temperaturas da ordem de 165 ± 5°C por aproximadamente 9 horas. Considerando tempo e temperatura empregados nesta etapa, o objetivo deste estudo foi avaliar a carga microbiana dos implantes mamários de silicone antes do processo de vulcanização, assim como o decaimento da carga microbiana neste processo e também confirmar a esterilidade do gel contido internamente à membrana. Desta forma, foi possível observar que o nível de contaminação microbiana dos implantes gelatinosos é relativamente baixo e que a vulcanização foi um processo que possibilitou a inativação de até 108 esporos, a concentração de esporos mais alta utilizada no estudo. Os resultados mostraram que a vulcanização possibilitou não só a redução da carga microbiana, mas também consiste em mecanismo para garantir a esterilidade do gel interno ao produto. Desta forma, o processo esterilizante final teve como contribuição elevar o Nível de Garantia de Esterilidade (SAL ou Sterility Assurance Level), condição interessante ao se considerar a tendência de adoção da liberação paramétrica, assim como o conceito de validação combinado bioburden/indicador biológico em vez de sobre-morte. Avaliação complementar foi feita ao quantificar endotoxina nos implantes antes e após o processo de esterilização (calor seco e óxido de etileno), verificando-se que os processos considerados não alteram significativamente a quantidade de endotoxina. Ainda assim, em todas as situações foram obtidos níveis aceitáveis, conforme USP 31. / Silicone breast implants consist of biomaterials widely used in breast reconstitution surgeries after the occurrence of cancer, accidents, breast size correction (in case of different volume between both breasts)or in mammary augmentation for esthetic reasons. With a view to confer security in its application, directly related to patients health, great attention has been given to sterilization processes applied to biomaterials. Among these, dry heat is one of the most often employed. For a successful sterilization, it requires high temperatures for a long period, what may give rise to alteration of the implant characteristics. On the other hand, a preliminary stage of the implant production process is vulcanization, which consists of heating the implant to 165 ± 5°C for approximately 9 hours. Taking into account the time and temperature used in this stage, the aim of this work was to evaluate the bioburden of silicone breast implants prior to the vulcanization process and the decline in bioburden due to this process, and to confirm the sterility of the gel contained in the membrane. This study led us to the conclusion that the level of microbial contamination of gel implants is relatively low, and that vulcanization allowed for the inactivation of up to 100 million spores, the highest concentration of spores used in this study. The results obtained showed that vulcanization enabled not only the reduction of the microbial load, but also guaranteed the sterility of the gel inside the product. Thus, the final sterilizing process contributed to an increase in the Sterility Assurance Level, an interesting phenomenon if we consider the tendency toward adoption of parametric release and the concept of a combined validation bioburden/biological indicator rather than overkill. Complement evaluation was made measuring endotoxins in the implants before and after the sterilization process (dry heat and ethylene oxide), verifying that the considered processes do not modify the amount of endotoxin significantly, as expectation. Still thus, in all the situations had been gotten acceptable levels, as USP 31.
419

Sistemas de esterilização por plasma: estudos de compatibilidade em polímeros e eficácia esterilizante em produtos médico-hospitalares de calibres reduzidos e longa extensão / Plasma sterilization: study of polymer compatibility and sterilization effectiveness in long and narrow lumen medical devices

Débora Cristina de Oliveira 19 March 2007 (has links)
Recentes avanços nas ciências médicas têm contribuído significativamente para que novas tecnologias de materiais e processos tecnológicos ganhem espaço. No âmbito da esterilização de materiais poliméricos termossensíveis, empregados na fabricação de ampla gama de produtos médico-hospitalares, os processos que operam sob temperaturas compatíveis com estes materiais, gás óxido de etileno e radiação ionizante, agregam desvantagens importantes envolvendo, respectivamente, aspectos de toxicidade ocupacional, ambiental e ao paciente, bem como alterações intrínsecas aos mesmos. O processo inovador e potencialmente compatível por gás plasma representa promissora alternativa, onde o agente letal agrega entidades altamente reativas provenientes de gás ionizado por aplicação de descarga elétrica e originalmente desprovido de atividade microbicida. O presente trabalho teve por objetivo proceder a estudos que permitam conhecimento da eficácia esterilizante de processos empregando plasma de O2 puro e sua mistura com H2O2 em produtos médico-hospitalares de natureza polimérica, configuração tubular, longa extensão e calibre reduzido. Os lumens desses materiais foram preenchidos com suportes vítreos (lamínulas de 8 x 18mm) intencionalmente contaminados com biocargas restritas de Bacillus subtilis var. niger ATCC 9372, que atuaram como biosensores, constituindo os monitores biológicos. Esses dispositivos foram submetidos a ciclos por plasma sob distintas combinações de parâmetros envolvendo distintos sistemas (RIE e ICP), potências de rádio-freqüência e tempos de exposição sub-letais. Após os ciclos esterilizantes, os monitores biológicos foram abertos e submetidos à análise microbiológica para a enumeração de possíveis esporos sobreviventes, usando o método do número mais provável (NMP), possibilitando o cálculo dos valores D (principal parâmetro de resistência de uma população microbiana). Adicionalmente, foram objeto de investigação polímeros distintos utilizados na confecção de produtos médico-hospitalares, a fim de esclarecer a influência do plasma sobre as características intrínsecas desses materiais. Foram selecionados o poli (cloreto de vinila) - PVC, polietileno de alta densidade (HDPE), polipropileno (PP), poliuretano (PUR) e policarbonato (PC). As amostras foram expostas em ambos sistemas de plasma (RIE e ICP) usando gás O2 puro e sua mistura gasosa O2/H2O2, potências de RF de 150W e 300W e tempo de exposição de 30 min. As amostras foram submetidas a espectroscopia fotoacústica no infravermelho, microscopia eletrônica de varredura, microanálise e perfilometria a fim de avaliar possíveis danos aos polímeros expostos, assim como citotoxicidade in vitro para esclarecer sobre a biocompatibilidade dos mesmos. Os resultados demonstraram que a eficácia esterilizante do plasma foi dependente do calibre dos monitores biológicos e das potências de RF aplicadas. Os menores valores D foram obtidos para os monitores biológicos de maior calibre (7mm) e potências de 150W/300W em ambos sistemas RIE e ICP, respectivamente. A mistura gasosa O2/H2O2 apresentou maior efeito microbicida quando comparada ao O2 puro em ambos sistemas de plasma. Paralelamente, a exposição ao plasma levou à modificação em nível superficial (oxidação e aumento da rugosidade) para todos os polímeros expostos. Foi observado efeito mais agressivo quando usando plasma gerado em sistema ICP usando mistura gasosa O2/H2O2. Os dados sugerem que a massa interna ou bulk de todos as amostras não foi afetada, assim como as alterações observadas não promoveram modificação na biocompatibilidade dos polímeros estudados. / The sterilization of heat sensitive materials like medical devices made of polymers has been under intense investigation regarding new technologies and sterilization agents, as far as mechanical problems and innocuity of currency processes such as ionizing radiation and ethylene oxide gas, respectively, are concerned. Plasma sterilization of medical devices is emerging as an attractive substitute to conventional sterilization technologies, once is recognized as an atoxic and low-temperature process. It uses different gases that are activated by an electrical discharge, generating reactive species which promote lethal effect on microorganisms. In this work, it was performed experimental studies to evaluate the sterilization effectiveness of pure O2 and O2/H2O2 mixture gas plasma against a standard load of 103 Bacillus subtilis var. niger ATCC 9372 spores inoculated on 8 x 18mm glass carriers placed inside and in central position of PVC catheters 64cm long with internal diameters of 7mm and 1mm. These assemblages simulated the challenge of medical devices as biological monitors. The gas plasma sterilization efficiency was studied as a function of plasma systems (RIE and ICP), radio frequency powers and sub-lethal exposition times. After sterilization, the biological monitors were disassembled and the survivors were growth in trypticase soy broth using the most probable number (MPN) technique. Hence, it was possible to calculate the time D required to decrease a given population by a factor of 10 (90% reduction). On the other hand, there was a need to evaluate the safety of plasma sterilization in terms of polymer damage. Materials used in this study were: polyvinylchloride (PVC), high density polyethylene (HDPE), polypropylene (PP), polyurethane (PUR) and polycarbonate (PC). Samples were exposed to pure O2 and O2/H2O2 plasma sterilization using both plasma systems (RIE and ICP), radio frequency powers of 150W/300W and exposition time of 30 minutes. Fourier transform infrared photoacoustic spectroscopy (FT-IR/PAS), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and profilometry, which are surface and bulk characterization techniques, were used to study plasma sterilization polymers compatibility, as well as \"in vitro\" citotoxicity to acess the biocompatibility of exposed polymers. The results demonstrated that plasma antimicrobial activity depended on the inside catheters diameter and radio frequency powers. The smallest D values were obtained when using biological monitors of 7mm of internal diameter and 150W/300W of RF powers, in, respectively, RIE/ICP systems. The mixture O2/H2O2 exhibited higher microbicidal efficacy than pure O2 in both plasma systems. In addition, both plasma systems led to near-surface layers modification, with the increase of roughness and surface oxidation of all the polymers studied. ICP system and O2/H2O2 mixture were more effective to induce the surface modifications observed. The bulk of all polymers showed not to be affected by all plasma conditions used and the surface alterations did not affected the biocompatibility of all the polymers studied.
420

Obtenção de biopolímeros de gelatina por radiação ionizante / Obtention of gelatin biopolymers by ionizing radiation

Patrícia Yoko Inamura Takinami 19 March 2014 (has links)
A gelatina (GEL) é um biopolímero biodegradável e biocompatível que forma naturalmente coloides semissólidos ou hidrogéis em soluções aquosas. Sendo um polímero hidrofílico, a GEL possui propriedades estruturais e físico-mecânicas que a distinguem de polímeros hidrofílicos sintéticos. São essas características que inspiraram o desenvolvimento do presente trabalho. Para analisa-las foram desenvolvidos filmes e hidrogéis de GEL utilizando radiação ionizante mediante diferentes técnicas: irradiação por 60Co, feixe de elétrons (EB) e/ou EB pulsado. Na elaboração de filmes a base de GEL foram incorporados diferentes aditivos, tais como glicerol (GLY), álcool polivinílico (PVA), hidroxitolueno butilado (BHT), acrilamida e/ou fibra vegetal. Esse produto filmes a base de GEL foi analisado quanto às suas propriedades mecânicas, cor, absorção de água, entre outros; e irradiado com doses de 10 a 60 kGy, dependendo do aditivo. Na síntese radioinduzida de nano-hidrogéis de GEL, polietileno glicol (PEG) e a mistura (MIX) de ambos os aditivos, GEL e PEG, foram analisados a dimensão, massa molar e morfologia das nanopartículas. Houve aumento significativo da fração gel com o aumento da dose de radiação nas amostras de GEL/fibra. Os filmes a base de GEL com 10% PVA irradiados a 20 kGy apresentaram a maior resistência à perfuração. A adição de antioxidante BHT influenciou em algumas das propriedades dos filmes a base de GEL nas condições aplicadas. Em relação aos nano-hidrogéis houve redução do raio hidrodinâmico da MIX irradiada com 60Co de 68 ± 25 nm (2 kGy) para 35 ± 4 nm (5 kGy). Tanto nos filmes quanto nos nano-hidrogéis de GEL, a radiação mostrou ser uma ferramenta conveniente na modificação de materiais poliméricos. / The gelatin (GEL) is a biocompatible and biodegradable biopolymer, which naturally forms semi-solid colloids or hydrogels in aqueous solutions. As a hydrophilic polymer, the GEL has structural and physico-mechanical properties that distinguish it from synthetic hydrophilic polymers. The study of these properties led to the development of the present work. Thus, GEL-based films and hydrogels were developed using ionizing radiation technology by different techniques: irradiation with 60Co, electron beam (EB) and/or pulsed EB. The GEL based-films enriched with different additives, such as glycerol (GLY), polyvinyl alcohol (PVA), butylated hydroxytoluene (BHT), acrylamide and/or vegetal fiber, were irradiated with doses from 10 to 60 kGy, depending on the additive; some parameters like mechanical properties, color, and water absorption were analyzed. In the radio-induced synthesis of GEL nanohydrogels, polyethylene glycol (PEG) and the mixture (MIX) of additives, PEG and GEL, the size, molar mass and surface morphology of the nanohydrogels were analyzed. There was a significant increase of gel fraction with increase of the radiation dose for the GEL/fiber samples. The GEL based-films with 10% PVA irradiated at 20 kGy showed the highest puncture strength. The addition of antioxidant BHT affected on some GEL based-films properties on applied conditions. Regarding the nanohydrogels, there was a decrease of hydrodynamic radius of MIX irradiated with 60Co from 68 ± 25 nm (2 kGy) to 35 ± 4 nm (5 kGy). The radiation proved to be a convenient tool in the modification of polymeric materials for both, GEL films and hydrogels.

Page generated in 0.0532 seconds