• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 22
  • 12
  • 12
  • 9
  • 6
  • Tagged with
  • 89
  • 59
  • 29
  • 24
  • 23
  • 15
  • 13
  • 13
  • 12
  • 11
  • 11
  • 11
  • 9
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Stereotactic vacuum-assisted biopsy (SVAB) of nonpalpable breast microcalcifications: advantage of clip placement (prospective study)

Liu, Fang. January 2008 (has links)
Ulm, Univ., Diss., 2008.
2

Les Onychomycoses, apport de la biopsie ungueale : à propos de 2 373 cas étudiés au Laboratoire de Mycologie médicale du C.H.U. de Nancy.

Weisbecker, Christine Mauss, January 1900 (has links)
Th.--Méd.--Nancy 1, 1984. N°: 209.
3

Cryobiopsie pulmonaire transbronchique et biopsie pulmonaire chirurgicale : étude prospective multicentrique de concordance

Fortin, Marc 26 March 2024 (has links)
Thèse ou mémoire avec insertion d'articles. / Les cryobiopsies transbronchiques (cBTB) ont démontré des résultats prometteurs dans l'investigation des maladies pulmonaires interstistielles (MPI), mais les données les comparant à l'étalon-d'or, la biopsie pulmonaire chirurgicale (BPC), sont conflictuelles. Nous avons donc mené une étude multicentrique prospective ayant pour but d'évaluer la concordance diagnostique intra et inter centre au niveau histopathologique ainsi qu'au niveau de la discussion pluridisciplinaire (DPD) entre les diagnostics obtenus par CBTB et BPC lors de l'investigation des MPI. Vingt patients ont subi des CBTB et BPC appariées qui ont démontré une concordance diagnostique intra centre en DPD chez 37 des 60 cas appariés (61.7%) (k = 0,46 (IC95 0,29-0,63)). Notre étude démontre une concordance diagnostique modérée entre le DPD obtenu par CBTB lorsque comparé au diagnostic obtenu par l'étalon-d'or, la BPC / Transbronchial cryobiopsies (TBCB) for the investigation of interstitial lung disease (ILD) obtained promising early results but data comparing them to the gold standard, surgical lung biopsies (SLB), are conflicting. We performed a prospective multicenter study to evaluate concordance between and with in center in histopathologic and multidiscriplinary discussion (MDD) diagnosis obtained with TBCB and SLB in the investigation of ILD. Twenty patients underwent contemporaneous TBCB and SLB. Within center diagnostic concordance at MDD was obtained in 37 of 60 matched cases (61.7%) (k = 0,46 (IC95 0,29-0,63)). This study demonstrates moderate diagnostic concordance at MDD between TBCB and, gold standard, SLB
4

Vakuumstanzbiopsie nonpalpabler mammographischer Befunde mit manueller Führung / Manually guided vacuum-assisted biopsy of nonpalpable mammographic findings

Völker, Nina January 2007 (has links) (PDF)
Zur Abklärung malignitätsverdächtiger Befunde in der Brust benötigt man eine effektive minimal-invasive Methode. Diese retrospektive Studie evaluiert die Wertigkeit der Vakuumstanzbiopsie mit manueller Führung. Es zeigt sich, dass hier eine unkomplizierte und ausreichende Gewinnung von Gewebe und somit eine zuverlässige Einschätzung von mammographischen Auffälligkeiten möglich ist. / The clarification of suspect mammographic findings requires an efficient minimal-invasive method. In this dissertation the manually guided vacuum-assisted breast biopsy is evaluated. It proves to be an uncomplicated and sufficient tissue extraction technique allowing a reliable clarification of mammographic findings.
5

Methodology and implications of lymphatic mapping and sentinel lymphadenectonomy

Tanis, Pieter Job, January 2002 (has links)
Proefschrift Universiteit van Amsterdam. / Met bibliogr., lit. opg. - Met samenvatting in het Nederlands en Spaans.
6

Développement d'une sonde de spectroscopie de réflectance diffuse résolue spatialement pour la caractérisation de tissus épithéliaux

De Tillieux, Philippe 23 September 2024 (has links)
La spectroscopie de réflectance diffuse résolue spatialement (SRDrs) est une méthode de biopsie optique qui cherche à estimer les spectres des propriétés d'absorption et de diffusion d'un tissu. Ces spectres contiennent une information riche sur la composition biochimique du tissu sondé ainsi que sur son histoarchitecture. Un des domaines d'applications est la dermatologie, où la SRDrs s'avère particulièrement adaptée à la détection de mélanomes. Une détection précoce des mélanomes est étroitement liée à un meilleur pronostic de la maladie. Puisque les tissus cancéreux ont une composition biochimique et une histoarchitecture différente des tissus sains, la SRDrs est un outil efficace pour assister les médecins au moment du diagnostic. Le principal avantage de la SRDrs par rapport à d'autres méthodes de biopsie optique est que l'instrumentation est très simple, ce qui permet de développer des montages compacts, portables et peu dispendieux. De plus, le signal spectral rétrodiffusé permet d'estimer simultanément les spectres d'absorption et de diffusion. Le principal inconvénient de la SRDrs est sa résolution spatiale. En effet, il est difficile de sonder un tissu très localement car le signal lumineux est typiquement envoyé par une fibre optique d'illumination et est collecté par plusieurs fibres de détection situées à différentes distances de la fibre d'illumination. Cette disposition offre peu de contrôle sur le volume échantillonné par la lumière. Ce volume dépend du positionnement des fibres d'illumination et de détection ainsi que des propriétés du milieu. Plus le volume échantillonné est grand, plus la lumière risque d'interagir avec différentes structures dans le tissu. Ceci est problématique puisque le milieu est généralement considéré comme homogène lors de la modélisation numérique de la propagation des photons. Cette approximation n'est pas appropriée pour les tissus épithéliaux qui présentent généralement une structure en couches. L'objectif de ce projet est de développer une sonde de SRDrs pour l'évaluation quantitative des spectres des propriétés optiques de milieux bicouches, en particulier pour la détection de mélanomes. La première partie de ce projet investigue la profondeur échantillonnée minimale qu'il est possible d'atteindre en SRDrs tout en respectant les conditions de validité des approximations du modèle numérique. Lorsque les conditions de validité des approximations ne sont pas respectées, l'estimation des propriétés optiques est alors qualitative plutôt que quantitative. Une estimation qualitative peut être suffisante pour assister au diagnostic, mais une estimation quantitative permet d'améliorer la connaissance sur la composition biochimique et l'histoarchitecture des tissus. De plus, des mesures quantitatives permettent de comparer les résultats entre différents montages expérimentaux. Pour évaluer la profondeur échantillonnée minimale en SRDrs, une méthodologie est développée pour définir les distances minimales et maximales entre les fibres d'illumination et de détection nécessaires à une évaluation quantitative des propriétés optiques. Afin de réduire au minimum la profondeur échantillonnée, le cas de fibres inclinées par rapport à la surface est considéré. La deuxième partie du projet consiste en une analyse numérique du problème inverse en SRDrs. L'objectif est de concevoir la géométrie d'une sonde qui permet d'estimer quantitativement les spectres des propriétés optiques d'un milieu bicouche. Pour ce faire, un modèle numérique pour estimer les propriétés optiques d'un milieu bicouche à partir de mesures de réflectance est développé. Le coût de calcul de ce modèle est très élevé. Diverses stratégies telles que l'utilisation de simulations de Monte Carlo à l'aide de cartes graphiques et la parallélisation massive sur des serveurs externes sont utilisées pour réduire le temps de calcul. Le modèle numérique est ensuite utilisé pour analyser l'effet de chaque paramètre géométrique de la sonde sur l'estimation des propriétés optiques. Les paramètres tels que le nombre de fibres optiques, leur positionnement et leur inclinaison sont successivement testés. Une géométrie de la sonde qui optimise la précision et la robustesse de l'estimation des propriétés optiques est développée. La géométrie choisie respecte les contraintes du modèle numérique présentées à la première partie et les contraintes expérimentales liées à la détection de mélanomes. Cette géométrie de sonde est ensuite validée numériquement en simulant des données artificielles bruitées. Les capacités et les limites de la sonde à estimer les propriétés de milieux bicouches sont caractérisées. Dans la troisième partie du projet, la sonde est fabriquée et intégrée à un montage expérimental de SRDrs. Des méthodes de traitement de signal et d'étalonnage sont développées à partir de mesures expérimentales. Des fantômes optiques homogènes et bicouches de propriétés connues sont utilisés pour valider les résultats numériques obtenus précédemment. La sonde et le modèle numérique d'estimation associé estiment les coefficients optiques de chacune des couches ainsi que la position de l'interface des fantômes optiques bicouches avec une erreur de moins de 20% pour des épaisseurs de la couche superficielle variant de 0.1 à 1.5 mm. Des mesures in vivo sur la peau sont acquises afin de démontrer l'intérêt de la sonde pour des applications dermatologiques. L'épaisseur estimée de l'épiderme concorde avec les valeurs rapportées dans la littérature. / Spatially resolved diffuse reflectance spectroscopy (srDRS) is an optical biopsy method that seeks to estimate a tissue's absorption and diffusion spectra. These spectra contain rich information about the biochemical composition of the tissue and its histoarchitecture. One area of application of srDRS is dermatology, where it is particularly well suited for detecting melanoma. Early detection of melanoma is closely related to a better prognostic. Because cancerous tissues have a biochemical composition and a histoarchitecture different from those of healthy tissues, srDRS is an efficient tool to assist medical practitioners during the diagnostic. The main advantage of srDRS compared to other optical biopsy methods is that the optical setup is simple, which allows the development of compact, portable, and cheap setups. Additionally, the backscattered spectral signal is used to simultaneously estimate the absorption and the scattering properties of the tissue. The main drawback is the spatial resolution because it is difficult to probe the sample in a very localized manner. This is because the light signal is typically sent from an illumination optical fiber and is collected by several detection fibers placed at different distances from the illumination fiber. This geometry offers little control over the volume sampled by light. The sampled volume depends on fiber placement as well as the optical properties of the sample. The greater the sampled volume is, the higher the probability of light interacting with several structures. This is problematic because the sampled volume is generally assumed to be homogeneous while modeling photon propagation inside the tissue. This assumption is not adequate for epithelial tissues, which often present a layered structure. The goal of this project is to develop an srDRS probe to quantitatively estimate the spectra of optical properties in bilayered media. The primary considered application for the probe is melanoma detection. The first part of the project is to investigate the minimal sampled depth that is achievable in srDRS while respecting the conditions for which the approximations in the numerical model are valid. When these conditions are not respected, the estimation of the optical properties can only be qualitative, as opposed to quantitative. A qualitative estimation may be sufficient to assist in the diagnostic, but a quantitative estimation can improve our knowledge of tissue structure and composition and has the added benefit of being comparable across different optical setups. To evaluate the minimal sampled depth in srDRS, a methodology is developed to define the minimal and maximal distances between the illumination and detection fibers that are required to obtain a quantitative estimation of the optical properties. To reduce as much as possible the sampled depth, fibers tilted with respect to the tissue's surface are considered. The second part of the project consists in a numerical analysis of the inverse problem in srDRS, where the goal is to design a probe geometry that allows a quantitative estimation of the optical properties' spectra in a bilayered medium. To carry out this analysis, a numerical model to estimate the optical properties of a bilayered medium from reflectance measurements is developed. The computation cost for this model is very high, so several strategies, such as using GPUs for the Monte Carlo simulations and massively parallelizing the problem on computing clusters, are used to reduce the computation time. The numerical model is then used to analyze the effect of each geometrical parameter of the probe on the estimation of the optical properties. The effect of each parameter, such as the number of optical fibers, their placement, and tilt angles are iteratively tested. A probe geometry is chosen to optimize the precision and robustness of the estimation of the optical properties. The chosen geometry satisfies the constraints of the numerical model presented in the first part as well as the experimental constraints related to melanoma detection. The chosen geometry is then numerically validated. By using synthetic noisy data, the capacities and limits of the probe to estimate the properties of bilayer media are characterized. In the third part, the probe is built and integrated into an experimental srDRS setup. A signal processing and a calibration scheme are developed and applied to experimental measures. Homogeneous and bilayer optical phantoms with known optical properties are used to validate the numerical results obtained in the second part of the project. The probe and the numerical model estimate the optical properties of each layer as well as the position of the interface between the two layers in bilayer phantoms with an estimation error of less than 20% when the thickness of the superficial phantom is between 0.1 and 1.5 mm. In vivo measures on the skin are acquired to demonstrate the capabilities of the probe for dermatological applications. The estimated epidermal thickness corresponds to the values reported in the literature.
7

L'Artérite temporale de Horton : étude morphologique à propos de 69 biopsies, comparaison avec les lésions de l'artère temporale sénescente.

Archen, Jacques, January 1900 (has links)
Th.--Méd.--Nancy 1, 1983. N°: 11.
8

Role aspirinu v prevenci rakoviny kolorektálního karcinomu / The role of Aspirin in the prevention of Colorectal Cancer

Galas, Ron Eric January 2009 (has links)
Non-steroidal Antiinflammatory Drugs have been shown to play an important role in the chemotherapeutic prevention of Colorectal Cancer. Their mechanism in doing so has been proven as far as scientific works today allow results and an understanding of this mechanism. Without a doubt, many aspects of this drug in terms of chemotherapy tailored to the treatment of Colorectal Cancer remain to be illuminated and are subject to further investigations. Whether a cyclooxygenase inhibitor can be used as a chemopreventive agent needs to be assessed in each case individually and the whole view of a patient must be taken into account considering his overall status of health and the exclusion of the potential harm of side effects. Given the fact that these drugs provide protection of Colorectal Cancer to a certain extent, their use will most probably increase in countries where they are easily accessable.
9

Small- und Large-fiber-Beteiligung bei Morbus Parkinson / Small- and large-fiber-neuropathy in Parkinson's disease

Ebert, Sönke January 2015 (has links) (PDF)
Die hier vorliegende Forschungsarbeit überprüfte eine mögliche Beteiligung des peripheren Nervensystems bei M. Parkinson und den atypischen Parkinson-Syndromen. 31 Patienten mit einem idiopathischen Parkinson-Syndrom (IPD-Patienten) und neun Patienten mit einem atypischen Parkinson-Syndrom (APD-Patienten) sowie 35 altersentsprechende Kontrollprobanden wurden zwischen 2011 und 2012 für diese Studie rekrutiert. Neben der Eigenanamnese und der neurologischen Untersuchung erhielten die Patienten eine Suralisneurographie zur Überprüfung der large fibers und eine Quantitative sensorische Testung (QST) zur Detektion einer möglichen Small-fiber-Dysfunktion. Die Vitamin-Bestimmung diente der Untersuchung möglicher Zusammenhänge zwischen der Levodopa-Therapie, eventuell daraus resultierenden Vitamin-Mangelzuständen und einer reduzierten intraepidermalen Nervenfaser-Dichte (IENF-Dichte) beim M. Parkinson. Für die histologische Auswertung der IENF-Dichte und der dermalen, myelinisierten Nervenfaserbündel (PGP 9.5- / MBP- Doppelfärbung) sowie für die immunohistochemische Untersuchung der Nervenfasersubtypen (anti-alpha-CGRP- und anti-Substanz P-Antikörper) wurden bei jedem Probanden vier Hautbiopsien von den Extremitäten und dem Körperstamm entnommen. Sieben IPD-Patienten und ein Proband mit einem atypischen Parkinson-Syndrom wiesen ein vermindertes sensorisches Nervenaktionspotenzial (SNAP) in der Suralisneurographie auf. Dagegen war eine pathologisch reduzierte Nervenleitgeschwindigkeit nur bei einem IPD-Patienten nachweisbar. Auffällig war zudem eine negative Korrelation zwischen der Erkrankungsdauer und dem SNAP (Korrelationskoeffizient -0,367, p<0,03). In der Auswertung der Hautbiopsien konnte eine statistisch signifikante Reduktion der myelinisierten Bündel am Unterschenkel der IPD-Patienten festgestellt werden. Bei zehn von 30 IPD-Patienten, jedoch bei keinem der Probanden mit einem atypischen Parkinson-Syndrom, konnte eine verminderte IENF-Dichte nachgewiesen werden. In der statistischen Überprüfung wurde außerdem am Unterschenkel ein signifikanter Unterschied zwischen den IPD-Patienten und der Kontrollkohorte sowie eine negative Korrelation zwischen der Krankheitsdauer und der IENF-Dichte (Korrelationskoeffizient -0,320, p<0,05) festgestellt. Die QST konnte dagegen keinen statistisch signifikanten Unterschied zwischen den einzelnen Kohorten aufzeigen. Im Kontrast dazu fand sich eine längenunabhängige Reduktion der CGRP-positiven und der Substanz P-positiven IENF-Dichte bei den Patienten mit einem idiopathischen Parkinson-Syndrom. Bemerkenswert war zudem eine signifikante Verminderung der Substanz P-positiven intraepidermalen Nervenfasern am Oberschenkel und Rücken bei den APD-Patienten. Eine statistisch signifikante Abweichung der CGRP- und Substanz P-positiven Bündel konnte dagegen nicht festgestellt werden. In der laborchemischen Untersuchung war ein Zusammenhang zwischen den bestimmten Vitamin-Spiegeln und der kumulativen Levodopa-Dosis sowie zwischen den Vitaminen und der IENF-Dichte lediglich bei dem Vitamin B6 nachweisbar. Zusammengefasst erscheint eine Beteiligung des peripheren Nervensystems beim idiopathischen Parkinson als wahrscheinlich, wohingegen bei den atypischen Parkinson-Syndromen vor allem von einer zentralen Genese ausgegangen werden kann. Basierend auf den Ergebnissen der Suralisneurographie und der Bestimmung der myelinisierten Bündel erscheint eine krankheitsbedingte Large-fiber-Beeinträchtigung beim M.Parkinson möglich. Die nachgewiesene längenabhängige Small-fiber-Reduktion bei IPD-Patienten wird vermutlich durch eine axonale Transportstörung verursacht. Einen krankheitsbedingten Erklärungsansatz für die längenunabhängige Reduktion der CGRP-positiven und der Substanz P-positiven IENF-Dichte bei IPD-Patienten liefert der Nachweis von neurotoxischem α-Synuclein in den sensiblen Spinatganglien mit einem daraus resultierenden Untergang von sensorischen Nervenfasern. Aufgrund der geringen Anzahl an Parkinson-Patienten mit sensiblen Symptomen und dem fehlenden Nachweis eines statistisch signifikanten Unterschiedes in der QST liegt der Verdacht nahe, dass die ermittelte intraepidermale Nervenfaserreduktion der IPD-Patienten nicht stark genug ausgeprägt ist, um eine signifikante Abweichung der QST-Ergebnisse zu verursachen. Weiterhin konnte kein Zusammenhang zwischen der kumulativen Levodopa-Menge, den Vitaminen B12, Methylmalonsäure sowie Homocystein und dem Auftreten einer Nervenfaserverminderung nachgewiesen werden, was gegen eine iatrogene Beteiligung des peripheren Nervensystems als Nebenwirkung der Levodopa-Therapie spricht. Das idiopathische Parkinson-Syndrom geht mit einer Reduktion der kleinen Nervenfasern einher, welche vermutlich auf die Grunderkrankung selbst zurückzuführen ist. Die Untersuchung der Haut erscheint somit vielversprechend für die Erforschung der Pathogenese und für die Differentialdiagnostik des M. Parkinson. / Small- and large-fiber-neuropathy in Parkinson's disease
10

Exploration biologique de l'atteinte rénale du lupus érythémateux disséminé.

Moussu, Marie-Agnès. January 1976 (has links)
Thèse--Méd.--Reims, 1976. N°: N° 102. / Bibliogr. f. 76-82.

Page generated in 0.057 seconds