Mechanical and Electrical Properties of Single-walled Carbon Nanotubes Synthesized by Chemical Vapor Deposition

Yang, Yuehai 17 May 2013 (has links)
Despite the tremendous application potentials of carbon nanotubes (CNTs) proposed by researchers in the last two decades, efficient experimental techniques and methods are still in need for controllable production of CNTs in large scale, and for conclusive characterizations of their properties in order to apply CNTs in high accuracy engineering. In this dissertation, horizontally well-aligned high quality single-walled carbon nanotubes (SWCNTs) have been successfully synthesized on St-cut quartz substrate by chemical vapor deposition (CVD). Effective radial moduli (Eradial) of these straight SWCNTs have been measured by using well-calibrated tapping mode and contact mode atomic force microscopy (AFM). It was found that the measured Eradial decreased from 57 to 9 GPa as the diameter of the SWCNTs increased from 0.92 to 1.91 nm. The experimental results were consistent with the recently reported theoretical simulation data. The method used in this mechanical property test can be easily applied to measure the mechanical properties of other low-dimension nanostructures, such as nanowires and nanodots. The characterized sample is also an ideal platform for electrochemical tests. The electrochemical activities of redox probes Fe(CN)63-/4-, Ru(NH3)63+, Ru(bpy)32+ and protein cytochrome c have been studied on these pristine thin films by using aligned SWCNTs as working electrodes. A simple and high performance electrochemical sensor was fabricated. Flow sensing capability of the device has been tested for detecting neurotransmitter dopamine at physiological conditions with the presence of Bovine serum albumin. Good sensitivity, fast response, high stability and anti-fouling capability were observed. Therefore, the fabricated sensor showed great potential for sensing applications in complicated solution.
92

Towards label-free biosensing in compact disk technologies f or point-of-need analysis

Avellà Oliver, José Miguel 01 September 2017 (has links)
This thesis explores new analytical advances using compact disk biosensing technologies, and comprises six scientific publications distributed along four chapters. Special attention is herein payed to Thermochromic Etching Disks (TED) technology (Chapter 1), rational design of disk-based biorecognition assays (Chapter 2), and label-free detection systems for point-of-need analysis (Chapters 3 and 4). First, insights into a novel light-mediated signal developing system for biorecognition assays (based on TED disks and drives) are provided together with an overview of the state-of-the art and future trends in photo- and thermochromic biosensing. This signal developing approach exploits photo- and thermochromism for biosensing in an original manner and represents a potential strategy to simplify signaling processes in bioanalytical systems. Then, how to transform TED technology into lab-on-a-disk systems is addressed. TED has proven to be a very versatile tool to perform sensitive analysis of biorecognition assays, using platforms and scanners easily obtained from regular disks and drives, respectively. Biologically relevant assays of different nature (microarray, cell culture, immunofiltration, turbidimetry, etc.) have been arrayed in a single disk and sensitively analyzed by imaging. Regarding rational design, a theoretical-experimental method (INSEL) based on kinetics and mass-transport modelling for optimizing biorecognition assays and exploring their behavior is presented. INSEL has been implemented as an in silico tool that enables to characterize biointeractions with minimal experimentation, to perform optimizations directed towards custom objectives defined by the user, and to easily compute the effect of critical variables without further experiments. In another study included in this thesis, polycarbonate grooved structures obtained from standard recordable disks (CD-R and DVD-R) were coated with silver and tailored to become SERS-active. This strategy represents a cost-effective and industrially scalable alternative to the SERS substrates typically used for bioanalysis. These disk-based materials have presented tunable plasmonic responses, significant Raman enhancement, and have allowed complex biological targets (such as proteins and exosomes) to be analyzed by SERS without using labeled reagents as tracers. In addition to introduce inexpensive and large-scale SERS substrates for biosensing, this study also suggests the development of prospective Raman scanners based on disk drives. Another approach herein presented addresses the implementation of diffraction-based sensing (DBS) in TED technology in order to conceive disk-based label-free biosensors based on standard disks and drives. At first, a comprehensive experimental assessment of the analytical possibilities offered by DBS is presented. Then, the fabrication of arrays of diffractive protein networks on TED disks is investigated, with which sensitive analysis of antibodies in label-free conditions has been demonstrated, using adapted drives as scanners. This investigation provides important insights into cost-effective and industrially scalable functional materials and detection setups that exploit consumer electronics for label-free biosensing. / Esta tesis explora nuevos avances en química analítica usando tecnologías de biosensado basadas en sistemas de disco compacto y comprende seis publicaciones científicas distribuidas a lo largo de cuatro capítulos. Los estudios se han centrado en la tecnología Thermochromic Etching Disks (TED) (Capítulo 1), el diseño racional de ensayos de bioreconocimiento en discos compactos (Capítulo 2), y la detección sin marcaje para realizar análisis in situ (Capítulos 3 y 4). Primero, enmarcado en una discusión del estado del arte y futuras tendencias en biosensado foto y termocrómico, se presenta un nuevo sistema (basado en discos y lectores TED) mediado por luz para el desarrollo de señales en ensayos de bioreconocimiento. Ésta constituye una estrategia novedosa para aprovechar el foto y termocromismo en biosensado, y presenta un gran potencial para simplificar los procesos de desarrollo de señal en sistemas bioanalíticos. A continuación, se aborda cómo transformar la tecnología TED en sistemas analíticos integrados basados en discos compactos. TED ha demostrado ser una herramienta muy versátil para analizar, de forma sensible, ensayos de bioreconocimiento usando plataformas y escáneres fácilmente obtenidos a partir de discos y lectores convencionales, respectivamente. Un único disco ha mostrado poder albergar varios ensayos biológicos importantes y de distinta naturaleza (micromatriz, cultivos celulares, inmunofiltración, turbidimetría, etc.), para ser analizados de forma sensible a través de imágenes En cuanto al diseño racional, se presenta un método teórico-experimental (INSEL), basado en modelos cinéticos y de transporte de masa, para optimizar ensayos de bioreconocimiento y explorar su comportamiento. INSEL se ha implementado como una herramienta in silico que permite caracterizar biointeracciones mediante mínima experimentación, realizar optimizaciones dirigidas a objetivos particulares definidos por el usuario, y computar el efecto de variables críticas de forma sencilla y sin experimentos adicionales. En otro estudio incluido en esta tesis, nanoestructuras en forma de surco obtenidas a partir de discos regrabables convencionales (CD-R y DVD-R) fueron recubiertas con plata y adaptadas para ser activas en SERS. Esta estrategia supone una alternativa, económicamente efectiva e industrialmente escalable, a los sustratos SERS típicamente usados en bioanálisis. Estos materiales han mostrado respuestas plasmónicas sintonizables, una amplificación Raman significativa, y han permitido analizar muestras biológicas complejas (como proteínas y exosomas) mediante SERS sin usar marcadores. Además de introducir sustratos SERS grandes y baratos, este trabajo también sugiere el desarrollo de escáneres Raman basados en lectores de disco. Otra aproximación presentada en esta tesis aborda la implementación de DBS (diffraction-based sensing) en tecnologías TED, con el fin de desarrollar biosensores para detección sin marcaje basados en discos y lectores convencionales. Primero, se presenta una amplia evaluación experimental de las posibilidades analíticas ofrecidas por DBS. A continuación, se investiga la fabricación de multitud de redes difractivas de proteínas sobre discos TED, con las que se ha demostrado la determinación sensible y sin marcaje de anticuerpos, usando lectores adaptados como escáneres analíticos. Esta investigación introduce avances importantes que apuntan al desarrollo de materiales funcionales y sistemas de detección, baratos e industrialmente escalables, que aprovechen las tecnologías de consumo para realizar biosensado sin marcaje. / Aquesta tesi explora nous avanços en la química analítica usant tecnologies de biosensat basades en sistemes de disc compacte, i comprèn sis publicacions científiques distribuïdes en quatre capítols. Els estudis s'han centrat en la tecnologia Thermochromic Etching Disks (TED) (Capítol 1), el disseny racional d'assajos de bioreconeixement en discos compactes (Capítol 2), i la detecció sense marcatge per realitzar anàlisi in situ (Capítols 3 i 4). Primer, dins del marc d'una discussió de l'estat de l'art i tendències futures en biosensat foto i termocròmic, es presenta un nou sistema (basat en discos i lectors TED) per al desenvolupament de senyals mitjançant llum, en assajos de bioreconeixement. Aquesta constitueix una nova estratègia per aprofitar el foto i termocromisme en biosensat, mentre que també presenta una gran potencial per simplificar els processos de desenvolupament de senyal en sistemes bioanalítics. Tot seguit, s'aborda com transformar la tecnologia TED en sistemes analítics integrats basats en discos compactes. TED ha demostrat ser una eina molt versàtil per analitzar, de forma sensible, assajos de bioreconeixement usant plataformes i escàners fàcilment obtinguts a partir de discos i lectors convencionals, respectivament. Un únic disc ha mostrat poder albergar diversos assajos biològicament importants i de distinta naturalesa (micromatrius, cultius cel·lulars, immunofiltració, turbidimetria, etc.), per a ser analitzats de forma sensible a través d'imatges. Pel que fa al disseny racional, es presenta un mètode teòric-experimental (INSEL), basat en models cinètics i de transport de massa, per optimitzar assajos de bioreconeixement i explorar el seu comportament. INSEL s'ha implementat com a una eina in silico que permet caracteritzar biointeraccions amb mínima experimentació, realitzar optimitzacions dirigides cap a objectius particulars definits per l'usuari, i computar l'efecte de variables crítiques de forma senzilla i sense experiments addicionals. En un altre estudi inclòs en aquesta tesi, nanoestructures en forma de solc obtingudes a partir de discos compactes regravables convencionals (CD-R i DVD-R) van ser recobertes amb plata i adaptades per a ser actives en SERS. Aquesta estratègia suposa una alternativa, econòmicament efectiva i industrialment escalable, als substrats SERS típicament usats en bioanàlisi. Aquests materials han mostrat respostes plasmòniques sintonitzables, una amplificació Raman significativa, i han permès analitzar mostres biològiques complexes (com proteïnes i exosomes) mitjançant SERS sense usar marcadors. A més d'introduir substrats SERS grans i barats, aquest treball també suggereix el desenvolupament d'escàners Raman basats en lectors de disc. Una altra aproximació presentada en aquesta tesi aborda la implementació de DBS (diffraction-based sensing) en tecnologies TED, per tal de desenvolupar biosensors basats en discos i lectors convencionals que permeten detecció sense marcatge. Primer, es presenta una amplia avaluació experimental de les possibilitats analítiques que ofereix aquesta tècnica. A continuació, s'investiga la fabricació de multitud de xarxes difractives de proteïnes sobre discos TED, amb les quals s'ha demostrat la determinació sensible i sense marcatge d'anticossos, usant lectors adaptats com a escàners analítics. Aquesta investigació introdueix avanços importants que apunten cap al desenvolupament de materials funcionals i sistemes de detecció, barats i industrialment escalables, que aprofiten les tecnologies de consum per dur a terme bioanàlisi sense marcatge. / Avellà Oliver, JM. (2017). Towards label-free biosensing in compact disk technologies f or point-of-need analysis [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/86128 / TESIS
93

Development of high sensitivity photonic sensing structures based on porous silicon substrates

Caroselli, Raffaele 10 September 2018 (has links)
La salud y el bienestar siempre han sido el centro de atención de muchas instituciones de investigación y empresas de todo el mundo. Esto llevó a la tecnología a desarrollarse en los campos químico, biológico, médico y clínico con el objetivo de proporcionar una mejor protección al ser humano. Como consecuencia, ha surgido una competición entre el tiempo necesario para que la enfermedad progrese y el tiempo necesario para que el hombre trate dicha enfermedad. Para ganar esta competición, es necesario actuar con anticipación, cuando la enfermedad aún no está demasiado desarrollada. Esto es posible realizando una detección precoz de la enfermedad. El logro de este objetivo allana el camino para el desarrollo de dispositivos ópticos de biosensado capaces de detectar la presencia de ciertas moléculas en concentraciones extremadamente bajas. Entre ellos, las estructuras integradas fotónicas están teniendo un gran éxito debido a su considerablemente alta sensibilidad. Sin embargo, el mecanismo de detección de estas estructuras se basa en la interacción entre la onda evanescente, que se propaga a lo largo de la superficie de la estructura, y el analito a detectar. De esta forma, no todo el campo que se propaga en la estructura fotónica se usa con fines de detección, sino solo una pequeña cantidad de éste. Esto representa una limitación crucial de los sensores basados en fotónica integrada. El objetivo de esta tesis doctoral es superar esta limitación y desarrollar estructuras fotónicas de sensado más sensibles que sean capaces de detectar las concentraciones más bajas posibles. Con este objetivo, nos centramos en el estudio del silicio poroso como plataforma para el desarrollo de estructuras ópticas con sensibilidades extremadamente altas gracias a que la interacción de sensado se realiza directamente dentro de la propia estructura, lo que permite explotar todo el campo que se propaga. / Health and well-being have always been the center of attention of many research institutions and companies around the world. This led the technology to develop in the chemical, biological, medical and clinical fields with the aim to provide a better protection to the human being. As a consequence, a competition is born between the time necessary to the disease to progress and the time necessary to man to treat such disease. In order to win this competition, it is necessary to act with anticipation, when disease is not too developed yet. This is possible by performing an early-detection. The achievement of this goal paves the way for the development of optical biosensing devices able to detect the presence of certain molecules at extremely low concentrations. Among them, photonic integrated structures are finding a great success due to their considerably high sensitivity. However, the sensing mechanism of these structures is based on the interaction between the evanescent wave, propagating along the structure surface, and the target analyte to detect. In this way, not all the field propagating in the photonic structure is used for sensing purposes, but rather only a small amount of it. This represents a crucial limitation of the integrated photonics based sensors. The aim of this PhD Thesis is to overcome this limitation and to develop more sensitive photonic sensing structures able to detect the lowest concentration possible. To this aim, we focused on the study of porous silicon as platform for the development of optical structures with extremely high sensitivities thanks to the fact that the sensing interaction takes place directly inside the structure itself, allowing to exploit all the field propagating in the structure. / La salut i el benestar sempre han sigut el centre d'atenció de moltes institucions de recerca i empreses de tot el món. Açò va portar a la tecnologia a desenvolupar-se en els camps químic, biològic, mèdic i clínic amb l'objectiu de proporcionar una millor protecció a l'ésser humà. Com a conseqüència, ha sorgit una competició entre el temps necessari per que la malaltia progresse i el temps necessari per que l'home tracte aquesta malaltia. Per a guanyar aquesta competició, és necessari actuar amb anticipació, quan la malaltia encara no està massa desenvolupada. Açò és possible realitzant una detecció precoç de la malaltia. L'assoliment d'aquest objectiu facilita el camí per al desenvolupament de dispositius òptics de biosensat capaços de detectar la presència de certes molècules en concentracions extremadament baixes. Entre ells, les estructures fotòniques integrades estan tenint un gran èxit a causa de la seua considerablement alta sensibilitat. No obstant açò, el mecanisme de detecció d'aquestes estructures es basa en la interacció entre l'ona evanescent, que es propaga al llarg de la superfície de l'estructura, i l'analit a detectar. D'aquesta forma, no tot el camp que es propaga en l'estructura fotònica s'usa amb finalitats de detecció, sinó solament una xicoteta quantitat d'aquest. Açò representa una limitació crucial dels sensors basats en fotònica integrada. L'objectiu d'aquesta tesi doctoral és superar aquesta limitació i desenvolupar estructures fotòniques de sensat més sensibles que siguen capaces de detectar les concentracions més baixes possibles. Amb aquest objectiu, ens centrem en l'estudi del silici porós com a plataforma per al desenvolupament d'estructures òptiques amb sensibilitats extremadament altes gràcies a que la interacció de sensat es realitza directament dins de la pròpia estructura, el que permet explotar tot el camp que es propaga. / Caroselli, R. (2018). Development of high sensitivity photonic sensing structures based on porous silicon substrates [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/107318 / TESIS
94

Nanoplasmonic Sensing of Disease-associated Extracellular Vesicles - An Ultrasensitive Diagnosis and Prognosis Approach

January 2020 (has links)
abstract: Extracellular vesicles (EVs) are membranous particles that are abundantly secreted in the circulation system by most cells and can be found in most biological fluids. Among different EV subtypes, exosomes are small particles (30 – 150 nm) that are generated through the double invagination of the lipid bilayer membrane of cell. Therefore, they mirror the cell membrane proteins and contain proteins, RNAs, and DNAs that can represent the phenotypic state of their cell of origin, hence considered promising biomarker candidates. Importantly, in most pathological conditions, such as cancer and infection, diseased cells secrete more EVs and the disease associated exosomes have shown great potential to serve as biomarkers for early diagnosis, disease staging, and treatment monitoring. However, using EVs as diagnostic or prognostic tools in the clinic is hindered by the lack of a rapid, sensitive, purification-free technique for their isolation and characterization. Developing standardized assays that can translate the emerging academic EV biomarker discoveries to clinically relevant procedures is a bottleneck that have slowed down advancements in medical research. Integrating widely known immunoassays with plasmonic sensors has shown the promise to detect minute amounts of antigen present in biological sample, based on changes of ambient optical refractive index, and achieve ultra-sensitivity. Plasmonic sensors take advantage of the enhanced interaction of electromagnetic radiations with electron clouds of plasmonic materials at the dielectric-metal interface in tunable wavelengths. / Dissertation/Thesis / Doctoral Dissertation Biomedical Engineering 2020
95

Studies toward the mechanism of allosteric activation in phenylalanine hydroxylase

Soltau, Sarah Rose 22 January 2016 (has links)
Phenylalanine hydroxylase (PAH, EC: 1.14.16.1) is a non-heme iron tetrahydropterin-dependent monooxygenase that maintains phenylalanine (L-Phe) homeostasis via conversion of L-Phe to L-Tyr. PAH is an allosteric enzyme that converts from an inactive T-state to an active R-state upon addition of substrate, L-Phe. Allosteric activation is correlated with physical and structural changes within the enzyme and a large activation energy. Crystal structures of PAH have not identified the location of the allosteric effector binding site. Herein, we report computational protein mapping efforts using the FTmap algorithm and experimental site-directed mutagenesis studies designed to define and screen possible L-Phe allosteric binding sites. Mass spectroscopic analysis of PAH proteolytic fragments obtained after photo-crosslinking with 2-azido-3-phenylpropanoate overlapped with one computationally derived allosteric binding pocket containing residues 110-120 and 312-317. Ligand docking studies, fluorescence measurements, binding affinity and activity assays on wild-type and mutant enzymes further characterized the shape and specificity of this pocket. Thermodynamic studies using surface acoustic wave (SAW) biosensing determined the affinity of L-Phe for the allosteric site. Two L-Phe binding sites were observed upon SAW titrations, corresponding to the active and allosteric sites respectively ( K D,app^on 113 ± 12 µM active site, K D,app^on 680 ± 20 µM allosteric site). Site-directed mutagenesis was performed to prepare mutant enzymes containing a single tryptophan (L-Trp) residue. The fluorescence signatures of each of the three native L-Trp residues in PAH were determined by titrations with L-Phe. Trp187 primarily reports L-Phe induced allosteric conformational changes, while Trp120 reports active site L-Phe binding. Trp326 reports small signals of both active and allosteric site changes. Variable temperature stopped-flow fluorescence kinetic studies elucidated a working mechanism for L-Phe allosteric activation of PAH. Fluorescent signals from wild-type, single, and double L-Trp PAH mutants have been used to build kinetic mechanisms for the L-Phe binding in each subunit and subsequent active site reorganization or allosteric conformational change. In these mechanisms, the enzyme has reduced activity (1-2% of wtPAH) until both L-Phe induced active and allosteric site conformational changes have occurred. Failure of either activation step prevents enzyme turnover and is the chemical-based cause of the metabolic condition phenylketonuria.
96

SERS spektroskopie modelových biomolekul pro SERS biosenzing / SERS spectroscopy of model biomolecules for SERS biosensing

Šubr, Martin January 2014 (has links)
Title: SERS spectroscopy of model biomolecules for SERS biosensing Author: Martin Šubr Department: Institute of Physics of Charles University Supervisor: doc. RNDr. Marek Procházka, Dr., Institute of Physics of Charles University Abstract: The main requirement for surface enhanced Raman scattering (SERS)-based biomolecular sensing is high sensitivity and spectral reproducibility. For this purpose, ordered silver and gold nanostructures fabricated by magnetron sputtering and lithography methods at cooperating institutes were tested in this work. Reproducible SERS spectra of employed model biomolecules (amino acids, lysozyme and albumin) were obtained on ordered silver surfaces at concentrations 10-4 M - 10-6 M and as low as ≈ 10-7 M in the case of porphyrins. SERS spectra of certain biomolecules were also compared to spectra measured on silver colloid. The limit of detection provided by hydroxylamine-reduced silver colloid, using KCl as an aggregating agent, is substantially lower (on the order of 10-8 M for cysteine), but with lower spectral reproducibility. The main drawback of SERS spectra measured on silver surfaces was the occurrence of spurious bands resulting from the preparation procedure. In the case of sputter-deposited silver surfaces, it was found that keeping the substrates several hours in...
97

Development of Gene Regulatory Elements for Biosensing Applications

Bates, Mallory N. 01 June 2022 (has links)
No description available.
98

Synthetic Metabolic Circuits for Bioproduction, Biosensing and Biocomputation / Circuits métaboliques synthétiques pour la bioproduction, la biodétection et le biocalcul

Pandi, Amir 27 September 2019 (has links)
La biologie synthétique est le domaine de la bioingénierie permettant de concevoir, de construire et de tester de nouveaux systèmes biologiques en réécrire le code génétique. Les circuits biologiques synthétiques sont des outils sophistiqués permettant de construire des réseaux biologiques pour des applications médicales, industrielles et environnementales. Cette thèse de doctorat porte sur le développement de voies métaboliques synthétiques conçues à l'aide d'outils informatiques. Ces voies métaboliques sont intégrées à la couche de régulation transcriptionnelle pour développer des biocircuits pour la bioproduction, la biodétection et la biocalcul dans des systèmes cellulaires et acellulaires. Les résultats obtenus durant cette thèse de doctorat révèlent le nouveau potentiel des voies métaboliques dans l'établissement de biocircuits synthétiques. Le volet bioproduction-biodétection de la thèse vise à développer un nouveau biocapteur pour un sucre rare utilisé pour améliorer l'activité catalytique d’enzyme dans la cellule (in vivo). Ce biocapteur a ensuite été implémenté dans un système acellulaire (in vitro) pour découvrir et optimiser le comportement de biocapteurs à base de répresseurs. Une fois optimisé en système acellulaire, notre biocapteur a été utilisé pour surveiller la production enzymatique de sucre rare. Le développement de biocapteurs procaryotes acellulaires, qui reposent principalement sur des répresseurs, permet d'accélérer et de rendre plus efficace le cycle “design-build-test” dans le prototypage des voies métaboliques dans les systèmes acellulaires. L'application de la biodétection des circuits métaboliques pour le diagnostic est la mise en œuvre et l'optimisation des transducteurs métaboliques dans le système acellulaire. Les transducteurs sont des voies métaboliques composées d'au moins une enzyme catalysant un métabolite indétectable en un inducteur transcriptionnel, augmentant ainsi le nombre de petites molécules biologiquement détectables. En tant que nouvelle approche pour effectuer des biocalculs, des circuits métaboliques ont été appliqués pour construire des additionneurs métaboliques et des perceptrons métaboliques. Dans la cellule, trois transducteurs métaboliques et un additionneur métabolique ont été construits et caractérisés. Les systèmes acellulaires permettent d’accélérer la caractérisation de circuits biologiques, de finement régler le niveau d’expression d’un ou plusieurs gènes et facilite l’expression de plusieurs plasmides simultanément. Ceci a permis de construire de multiples transducteurs pondérés et des additionneurs métaboliques. Le modèle basé sur des données expérimentales a permis de concevoir un perceptron métabolique pour construire des classificateurs binaires à quatre entrées. Les additionneurs, perceptrons et classificateurs peuvent être utilisés dans des applications avancées telles que la détection de précision et dans le développement de souches pour le génie métabolique ou la thérapeutique intelligente. / Synthetic biology is the field of engineerable life science and technology to design-build-test novel biological systems through reprogramming the code of DNA. Synthetic biocircuits are sophisticated tools to reconstruct biological networks for medical, industrial, and environmental applications. This doctoral thesis focuses on the development of synthetic metabolic pathways designed by computer-aided tools integrated with the transcriptional regulatory layer enabling bioproduction, biosensing, and biocomputation in whole-cell and cell-free systems. The achievements of this doctoral thesis bring attention to new potentials of metabolic pathways in the development of synthetic biocircuits. The bioproduction-biosensing section of the thesis is to build a novel sensor for a rare sugar used to improve the catalytic activity of its producing enzyme in the whole-cell system (in vivo). This sensor was then implemented in a TX-TL cell-free system (in vitro) as a proof of concept of a repressor based biosensor to discover and optimize the behavior of repressor based biosensors in the cell-free system that suffer from low fold repression. The optimized cell-free biosensor was then used to monitor the enzymatic production of the rare sugar. The development of cell-free prokaryotic biosensors which are mostly relying on repressors enables faster and more efficient design-build-test cycle in metabolic pathways prototyping in cell-free systems. The biosensing application of the metabolic circuits for diagnosis is the implementation and optimization of cell-free metabolic transducers. The transducers are metabolic pathways composed of at least one enzyme catalyzing an undetectable metabolite to a transcriptional inducer, hence expanding the number of biologically detectable small molecules in cell-free systems. Finally, as a radical approach to perform biocomputation, metabolic circuits were applied to build metabolic adders and metabolic perceptrons. In whole-cell system, three metabolic transducers and a metabolic adder (multiple transducers receiving multiple input metabolites and transform them into a common metabolite) were built and characterized. By taking advantage of cell-free systems in rapid characterization, high tunability, and the possibility of using tightly controlled multiple DNA parts, multiple weighted transducers and metabolic adders were implemented. The integrated model trained on the experimental data enabled the designing of a metabolic perceptron for building four-input binary classifiers. The adders, perceptrons and classifiers can be applied in advanced applications such as multiplex detection/precision medicine and in the development of designer strains for metabolic engineering or smart therapeutics.
99

Biocompatible noble metal nanoparticle substrates for bioanalytical and biophysical analysis of protein and lipids

Bruzas, Ian R. 07 June 2019 (has links)
No description available.
100

Engineering Nanoparticles Surface for Biosensing: "Chemical Noses" to Detect and Identify Proteins, Bacteria and Cancerous Cells

Miranda-Sanchez, Oscar Ramon 01 February 2011 (has links)
Rapid and sensitive detection of biomolecules is an important issue in nanomedicine. Many disorders are manifested by changes in protein levels of serum and other biofluids. Rapid and effective differentiation between normal and cancerous cells is an important challenge for the diagnosis and treatment of tumor. Likewise, rapid and effective identification of pathogens is a key target in both biomedical and environmental monitoring. Most biological recognition processes occur via specific interactions. Gold nanoparticles (AuNPs) feature sizes commensurate with biomacromolecules, coupled with useful physical and optical properties. A key issue in the use of nanomaterials is controlling the interfacial interactions of these complex systems. Modulation of these physicochemical properties can be readily achieved by engineering nanoparticles surface. Inspired by the idea of mimicking nature, a convenient, precise and rapid method for sensing proteins, cancerous cells and bacteria has been developed by overtaking the superb performance of biological olfactory systems in odor detection, identification, tracking, and location. On the fundamental side, an array-based/`chemical nose' sensor composed of cationic functionalized AuNPs as receptors and anionic fluorescent conjugated polymers or green fluorescent proteins or enzyme/substrates as transducers that can properly detect and identify proteins, bacteria, and cancerous cells has been successfully fabricated.