Spelling suggestions: "subject:"bisfenol"" "subject:"bisfenola""
71 |
Desenvolvimento e validação de metodologia cromatográfica para determinação de bisfenol A em simulantes de alimentos de ensaios de migração / Development and validation of chromatographic method for the determination of bisphenol A in food simulants of migration tests.Linhares Junior, Gilberto Ferreira January 2012 (has links)
LINHARES JUNIOR, Gilberto Ferreira. Desenvolvimento e validação de metodologia cromatográfica para determinação de bisfenol A em simulantes de alimentos de ensaios de migração. 2012. 101 f. : Dissertação (mestrado) - Universidade Federal do Ceará, Centro de Ciências Agrárias, Departamento de Tecnologia de Alimentos, Fortaleza-CE, 2012 / Submitted by Nádja Goes (nmoraissoares@gmail.com) on 2016-06-08T15:09:14Z
No. of bitstreams: 1
2012_dis_gflinharesjunior.pdf: 1691103 bytes, checksum: 0abb8d914beb4b36dee06bc962679c7b (MD5) / Approved for entry into archive by Nádja Goes (nmoraissoares@gmail.com) on 2016-06-08T15:09:30Z (GMT) No. of bitstreams: 1
2012_dis_gflinharesjunior.pdf: 1691103 bytes, checksum: 0abb8d914beb4b36dee06bc962679c7b (MD5) / Made available in DSpace on 2016-06-08T15:09:30Z (GMT). No. of bitstreams: 1
2012_dis_gflinharesjunior.pdf: 1691103 bytes, checksum: 0abb8d914beb4b36dee06bc962679c7b (MD5)
Previous issue date: 2012 / This study aimed to develop and chromatographic method for the determination of bisphenol A in four different food simulants using high performance liquid chromatography and diode array detector (PDA) to support in enasios migration. The simulating used were A (purified water), B (solution aquosade 3% acetic acid), C (aqueous 10% ethanol) and D (aqueous 95% ethanol). Preliminary assessment of the analytical conditions was conducted in order to establish those that confer the best results, which were the system of mobile phase acetonitrile-water in the ratio 70:30 by volume, 40 ° C oven and length of the column wavelength of 201 nm. The retention time of the bisphenol A was found to be 3.25 minutes. For simulating the method of treatment consists of evaporation of sample 1 ml of sample at 60 ° C with duration of 1 hour and 45 minutes (A and C), 2 hours (B) and 1 hour (D). In sequence, the method was evaluated with respect to the parameters of analytical validation, including linearity, limit of detection and quantification, repeatability, intermediate precision between different analysts and between different days, recovery, selectivity and robustness. The method for simulating the coefficient for determining (r ²) or greater than 0.9988 in the range tested (50 to 2000 ppb); detection limit and quantitation, respectively, 14.7 ppb and 48.9 ppb; coefficient variation in repeatability of 2.07% for the inter-day precision of 1.05% and the accuracy of inter-Analyst 1.76%, recovery of 97.9% (CV = 1.3%) (50 ppb ), 99.2% (CV = 0.7%) (1000 ppb) and 103.6% (CV = 0.4%). The results for the simulant B includes coefficient of determination (r ²) 0.9972 or higher; limit of detection and quantification, respectively, 7.8 ppb and 26.0 ppb; coefficients of variation for repeatability of 3.74%, inter day precision, accuracy and 0.14% cross-Analyst 0.2%, 94.8% recovery (CV = 4.8%) (50 ppb) and 99.8% (CV = 0.2% ) (1000 ppb) and 92.3% (CV = 1.2%) (2000 ppb). For the simulant C results include a coefficient of determination (r ²) 0.9988 or higher; limit of detection and quantification, respectively, 4.8 ppb and 16.1 ppb, coefficient of variation for repeatability of 2.84%, accuracy inter-day precision of 1.37% and inter-analysts of 0.14%; de104 recovery, 6% (CV = 2.5%) (50 ppb), 99.8% (CV = 1.3%) ( 1000 ppb) to 102.5% (CV = 2.9%) (2000 ppb). The results for simulating D was 0.9984 r ² or more, detection limit and quantitation, respectively, 13.7 ppb and 45.6 ppb; coefficient of variation of 2.0% to repeatability, accuracy of an inter-day 9% and accurate inter-de1 analysts, 2%; recuperção 92.6% (CV = 1.76%) (50 ppb) and 99.9% (CV = 0.9%) (1000 ppb) and 104 8% (CV = 2.7%) (2000 ppb). There were no significant interferences to the method tested and proved to be robust. / Este trabalho teve como objetivo o desenvolvimento e metodologia cromatográfica para a determinação de bisfenol A em quatro diferentes simulantes de alimentos utilizando cromatografia líquida de alta eficiência e detector de arranjo de diodo (PDA) para suporte em enasios de migração. Os simulantes utilizados foram A (água purificada), B (solução aquosade ácido acético a 3%), C (solução aquosa de etanol a 10%) e D (solução aquosa de etanol a 95%). A avaliação preliminar das condições de análise foi conduzida com a finalidade de estabelecer aquelas que conferem os melhores resultados, os quais foram o sistema de fase móvel acetonitrila-água na proporção volumétrica 70:30, temperatura de 40°C do forno da coluna e comprimento de onda em 201 nm. O tempo de retenção do bisfenol A encontrado foi de 3,25 minutos. Para os simulantes, o método de tratamento consistiu da evaporação de 1 ml de amostra amostra a 60°C com duração de 1 hora e 45 minutos (A e C), 2 horas (B) e 1 hora (D). Em sequência, o método foi avaliado com relação aos parâmetros de validação analítica, incluindo linearidade, limite de detecção e de quantificação, repetibilidade, precisão intermediária entre analistas diferentes e entre dias diferentes, recuperação,seletividade e robustez. O método desenvolvido para o simulante A apresentou coeficiente de determinação (r²) 0,9988 ou superior no intervalo testado (50 a 2000 ppb); limite de detecção e de quantificação , respectivamente, 14,7 ppb e 48,9 ppb; coeficiente de variação para repetibilidade de 2,07%, para a precisão inter-dias de 1,05% e para a precisão inter-analistas de 1,76%; recuperação de 97,9% (CV= 1,3%) (50 ppb), 99,2% (CV= 0,7%) (1000 ppb) e 103,6% (CV= 0,4%). Os resultados obtidos para o simulante B incluem coeficiente de determinação (r²) 0,9972 ou superior; limite de detecção e de quantificação, respectivamente, 7,8 ppb e 26,0 ppb; coeficientes de variação para repetibilidade de 3,74%, precisão inter-dias de 0,14% e precisão inter-analistas de 0,2%; recuperação de 94,8% (CV= 4,8%) (50 ppb), 99,8% (CV= 0,2%) (1000 ppb) e 92,3% (CV= 1,2%) (2000 ppb). Para o simulante C os resultados incluem coeficiente de determinação (r²) 0,9988 ou superior; limite de detecção e de quantificação, respectivamente, 4,8 ppb e 16,1 ppb; coeficiente de variação para repetibilidade de 2,84%, precisão inter-dias de 1,37%e precisão inter-analistas de 0,14%; recuperação de104,6% (CV= 2,5%) (50 ppb), 99,8% (CV= 1,3%) (1000 ppb) e 102,5% (CV= 2,9%) (2000 ppb). Os resultados para o simulante D foram r² 0,9984 ou superior; limite de detecção e de quantificação,respectivamente, 13,7 ppb e 45,6 ppb; coeficiente de variação para repetibilidade de 2,0%, precisão inter-dias de 1,9% e precisão inter-analistas de1,2%; recuperção de 92,6% (CV= 1,76%) (50 ppb), 99,9% (CV= 0,9%) (1000 ppb) e 104,8% (CV= 2,7%) (2000 ppb). Não foram observados interferentes importantes para o método testado, mostrando-se robusto.
|
72 |
Construção, caracterização e aplicação analítica de microdispositivos enzimáticosCerqueira, Marcos Rodrigues Facchini 09 September 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-03-21T18:21:21Z
No. of bitstreams: 1
marcosrodriguesfacchinicerqueira.pdf: 6161892 bytes, checksum: a58d0d5ce0d0b333fd8a3b50155105e4 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-22T12:39:49Z (GMT) No. of bitstreams: 1
marcosrodriguesfacchinicerqueira.pdf: 6161892 bytes, checksum: a58d0d5ce0d0b333fd8a3b50155105e4 (MD5) / Made available in DSpace on 2017-03-22T12:39:49Z (GMT). No. of bitstreams: 1
marcosrodriguesfacchinicerqueira.pdf: 6161892 bytes, checksum: a58d0d5ce0d0b333fd8a3b50155105e4 (MD5)
Previous issue date: 2016-09-09 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O foco deste trabalho foi o desenvolvimento e aplicação de microreatores enzimáticos, visando sua aplicação em sistemas de análise por injeção em fluxo. Em cima disso, dois substratos poliméricos foram utilizados para a avaliação de imobilização enzimática: um à base de poli (metil metacrilato) (PMMA) e outro em uma resina do éter diglicídico do bisfenol-A (BADGE). Uma impressora à laser de CO2 foi utilizada para confeccionar os dispositivos nas dimensões desejadas. Para o sucesso da imobilização, os sistemas foram previamente tratados com polietilenoimina (PEI) visando a introdução de grupamentos funcionais reativos na superfície dos materiais de partida. Num primeiro estudo, baseado na modificação de PMMA, a ativação do material foi conseguida após tratamento dos microcanais com PEI em meio de dimetilsulfóxido (DMSO). Já no segundo caso o tratamento com PEI envolveu a simples mistura mecânica dos materiais, objetivando a cura da resina empregada. Após a ativação dos materiais com PEI, as enzimas foram imobilizadas após passagem de uma mistura de glutaraldeído (um agente espaçador) e as enzimas. Dentre as enzimas estudadas estão a glicose oxidase (GOx), a ascorbato-oxidase (AAO), a catalase (CAT), a glutamato dehidrogenase (GDH), além de um sistema híbrido baseado na imobilização simultânea das enzimas glicose oxidase (GOx) e horseradish peroxidase (HPR). A caracterização dos sistemas desenvolvidos foi feita primordialmente por meio da espectroscopia Raman. Além disso, a aplicação de alguns dos sistemas frente a amostras reais e o cálculo de parâmetros cinéticos e operacionais dos microreatores confeccionados foram reralizados. Essas avaliações foram feitas baseadas em sistemas de detecção desenvolvidos no laboratório por técnicas eletroquímicas e por espectroscopia no visível. Como grande benefício dos sistemas desenvolvidos, podem ser destacados a velocidade e a simplicidade de implementação do processo de imobilização e operação. / The focus of this work is the development and application of enzymatic microreactors aiming their application through flow injection analysis systems. On top of that, two polymeric substrates were used for the evaluation of enzyme immobilization: one based on poly (methyl methacrylate) (PMMA) and another baed on a bisphenol-A diglycidyl ether resin (BADGE). A CO2 laser printer was used to fabricate the devices at the desired dimensions. For the success of the immobilization systems have been pretreated with polyethyleneimine (PEI) in order to introduce reactive functional groups on the surface of the starting materials. In a first study, based on PMMA modification, the activation of the material was achieved after treating microchannels with PEI in dimethylsulfoxide (DMSO). In the second case, treatment with PEI involved simply a mechanical mixture of the two materials, in order to cure the resin. After activation of materials with PEI, the enzymes were immobilized after passage of a mixture of glutaraldehyde (a spacer agent) and enzymes. Among the enzymes studied are glucose oxidase (GOx), ascorbate oxidase (AAO), catalase (CAT), dehydrogenase glutamate (GDH), and a hybrid system based on the simultaneous immobilization of the enzymes glucose oxidase (GOx) and horseradish peroxidase (HPR). The characterization of the developed systems was primarily done by Raman spectroscopy. Moreover, application of some of the proposed systems to real samples and calculation of kinetic and operational parameters are presented during the study. These evaluations were made with detection systems based on electrochemical and visible spectroscopy techniques, all developed at the laboratory. One great benefit of the developed systems, are the speed and simplicity of implementation the immobilization process and operation of the devices.
|
73 |
Retardéry hoření a jejich průnik do terestrického ekosystému / Flame retardants and their penetration into the terrestrial ecosystemChytil, Václav January 2014 (has links)
This diploma thesis was focused on the analysis of four compounds from brominated flame retardants group, namely pentabromoethylbenzene, hexabromocyclododecane, hexabromobenzene and tetrabromobisphenol A. Matrices were represented by four soil samples and four seat of fire samples. In addition, bisphenol A was also determined. First of all, process of extraction of analytes from matrices was optimized. Three different extraction techniques were tested (pressurized solvent extraction, microwave-assisted extraction and ultrasound-assisted extraction). Next step was to verify stability of target compounds in strongly acidic conditions and to optimize clean-up of extract by column chromatography. Gas chromatography with electron capture detection (GC-ECD) was chosen as an appropriate analytical method for the determination of brominated flame retardants. Bisphenol A was determined by gas chromatography with mass spectrometric detection (GC-MS). The derivatization of phenolic analytes before their final analytical determination was also essential.
|
74 |
Bisfenol A ve vodním ekosystému / Bisphenol A in water ecosystemNohelová, Gabriela January 2014 (has links)
This diploma thesis deals with Bisphenol A, especially with its impact on the aquatic ecosystem. Information about its properties, production and current use are summarized here. Its harmful impact on the environment, especially on the aquatic ecosystem and the human body is characterized. Also the methods of its degradation within the aquatic environment have been described. A summary of the options of a determination of Bisphenol A in water samples is incorporated and the method of gas chromatography with mass spectrometry (GC/TOF MS) and comprehensive two-dimensional gas chromatography with mass spectrometry (GCxGC/TOF-MS) is compared in the experimental part. Analytical determination precedes the isolation of the analyte from the water samples by solid phase extraction (SPE) using SupelcleanTM ENVITM - 18 and derivatization using the silylation reagent, N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA). The result of this work is the analysis of a series of real samples from wastewater treatment plants Brno Modřice and Luhačovice by a two-dimensional gas chromatography with mass spectrometry (GCxGC/TOF-MS).
|
75 |
Aplikace ligninolytických hub na pevných substrátech pro degradace endokrinních disruptorů / Application of ligninolytic fungi on solid substrates for degradation of endocrine disruptersSlavíková - Amemori, Anna January 2012 (has links)
Today a lot of attention is focused on compounds called endocrine disrupters (EDs) among substances released to environment by humans. They are a group of substances which can disturb function of hormonal system of organisms including humans. Their poor removal at wastewater treatment plants (WwTP) were shown at various studies, thus they can reach the environment in water. A prospective way for the degradation of EDs at WwTP can be their removal by ligninolytic fungi. They are able to degrade lots of lignin-like aromatic substances because of their highly nonspecific enzymes. In this work growth and enzyme production capability of four ligninolytic fungal strains were monitored on three solid substrates (straw pellets, poplar sawdust mixed with straw pellets, oak sawdust with straw pellets), which may be suitable substrates for fungal growth in bioreactors for wastewater treatment. Ability of these enzymes to degrade EDs were tested in in-vitro degradation experiment. Trametes versicolor was found as best degrading strain with 20 μg/ml of bisphenol A, 17 α- ethynylestradiol and nonylphenol degraded below a quantification limit within 24 hours. Fungal strains degraded EDs well on all of the three substrates but wood sawdust seemed to be a better substrate for fungal growth because straw pellets...
|
76 |
Comportamiento térmico y mecánico del poli(etilén tereftalato) (PET) modificado con resinas poliméricas basadas en bisfenol-ASánchez Mora, Johan José 07 November 2003 (has links)
Se realizó el estudio de las propiedades térmicas y mecánicas de mezclas de Poli(Etilén Tereftalato) (PET) con resinas poliméricas basadas enl Bisfenol-A: Poli(Carbonato de Bisfenol-A) (PC) y Poli(Hidroxi-Éter de Bisfenil-A) (PHEB), en contenidos no superiores a un 30% en peso de estos polímeros y preparadas por extrusión doble-husillo.Una evaluación físico-química (ft-IR, densidad y MVR) de ambos sistemas indicó que pueden ocurrir reacciones de transesterificación, principalmente entre el PET y el PC y verificado vía DSC y DMTA, mientras que dichas reacciones tienen una baja extensión en el caso del PHEB, principalmente evidenciado en la pérdida de la capacidad de cristalización del PET (sin mayores cambios en su transición vítrea) en presencia de PC y casi invariabilidad al adicionar PHEB. Con el apoyo de SEM se verificó la presencia de fases ricas de ambos componentes en las mezclas en todo el rango de composiciones, verificándose el carácter inmiscible de ambos sistemas.A través de un fraccionamiento térmico por Autonucleaciones y Recocidos Sucesivos (SSA) y medidas del MVR, ensayos que favorecieron la transesterificación, se estableció que ésta promueve un aumento de la masa molecular en ambos sistemas, donde en las mezclas PET/PC esto se da por reacciones de extensión de cadena y que en las mezclas PET/PHEB conducen a la formación de ramificaciones largas y entrecruzamientos.Las propiedades mecánicas a tracción y flexión indicaron un aumento de la resistencia mecánica y deformabilidad a mayor contenido de fase bisfenólica, al observarse un aumento de los parámetros característicos de estos ensayos, donde módulos elásticos y tensiones siguieron generalmente una desviación positiva de la "Ley Aditiva de Mezcla" (LAM). Tales tendencias indicaron un efecto rigidizante de la fase bisfenólica combinado con interacciones fuertes entre los componentes que favoreció la transmisión de tensiones y la deformabilidad de la mezcla, existiendo una compatibilidad mecánica aceptable al menos a bajas velocidades de deformación, principalmente en las mezclas PET/PC en donde hay evidencias de un aumento en la tenacidad. Se verificó que hay mejoras en la Resistencia al Impacto tanto caída de dardo como pendular al menos hasta un 20% de PC, superando a las mezclas PET/PHEB las cuales manifestaron una fuerte sensibilidad a la entalla.En el análisis de la fractura a través de la Mecánica de la Fractura Elástico Lineal (LEFM) a altas velocidades y el Trabajo Esencial de Fractura (EWF) a bajas velocidades de solicitación, para contenido no superiores a 10% de fase PC y PHEB donde la morfología de fases fue comparable (partículas), se tiene que los parámetros de fractura fueron siempre superiores para las mezclas PET/PC, con una tendencia general de que el PC aporta mejoras a estos parámetros respecto al PET, mientras que el PHEB no los afecta o tiende a disminuirlos. Esto sugiere que que la adhesión interfacial es un factor determinante que favorece la transmisión de tensiones, particularmente favorable en las mezclas PET/PC por su mayor reactividad.A mayores contenidos de fase bisfenólica, el comportamiento es más complejo como consecuencia del particular balance entre tamaño, geometría y orientación de la fase dispersa que tiende a dominar sobre la adhesión interfacial, detectándose procesos de cavitación en la mayoría de las condiciones de ensayos que promovieron pocas mejoras o decaimiento en los parámetros de fractura respecto al PET. Cabe destacar que los parámetros de fractura LEFM indicaron que todos los materiales presentaron una fractura en condiciones mixtas con una componente importante de tensión plana, con excepción de las mezclas PET/PHEB que corresponderían a condiciones de deformación plana, todo lo cual fue corroborado a través del análisis fractográfico.
|
Page generated in 0.0411 seconds