• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 193
  • 59
  • 35
  • 9
  • 9
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • Tagged with
  • 377
  • 377
  • 99
  • 54
  • 47
  • 41
  • 35
  • 33
  • 30
  • 30
  • 22
  • 21
  • 18
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Influence of microclimate on waterfowl energetics in a willow roost complex in Northeastern Missouri /

Magee, Patrick A. January 1996 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 1996. / Typescript. Vita. Includes bibliographical references (leaves 112-119). Also available on the Internet.
182

Influence of microclimate on waterfowl energetics in a willow roost complex in Northeastern Missouri

Magee, Patrick A. January 1996 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 1996. / Typescript. Vita. Includes bibliographical references (leaves 112-119). Also available on the Internet.
183

Thermoregulation in people with spinal cord injury

Wilsmore, Bradley R. January 2007 (has links)
Thesis (Ph.D.)--University of Wollongong, 2007. / Typescript. Includes bibliographical references.
184

Histamine receptors and substance P in cutaneous active vasodilation and thermal hyperemia in humans

Wong, Brett James. January 1900 (has links)
Thesis (Ph. D.)--University of Oregon, 2005. / Includes bibliographical references (leaves 195-207). Also available online (PDF file) by a subscription to the set or by purchasing the individual file.
185

Human thermal experimentation, analysis & control

Saw, Wee Hee. January 2003 (has links)
Thesis (M.S.)--University of Missouri-Columbia, 2003. / Accompany CD-ROM contains complete dissertation in Microsoft Word documents. Typescript. Vita. Includes bibliographical references. Also available on the Internet.
186

Histamine receptors and substance P in cutaneous active vasodilation and thermal hyperemia in humans /

Wong, Brett James, January 2005 (has links)
Thesis (Ph. D.)--University of Oregon, 2005. / Typescript. Includes vita and abstract. Includes bibliographical references (leaves 195-207). Also available for download via the World Wide Web; free to University of Oregon users.
187

Cutaneous active vasodilation in humans contribution of nitric oxide and vasoactive intestinal peptide /

Wilkins, Brad W., January 2003 (has links)
Thesis (Ph. D.)--University of Oregon, 2003. / Includes bibliographical references (leaves 137-145).
188

Verificação da existência de imprecisões nos valores do índice de isolamento térmico de vestimenta da norma ISO 9920:2007

Moura, Louisi Francis 02 March 2012 (has links)
O vestuário é um dos itens considerados como equipamento de proteção individual para ambientes de trabalho. Entre vários aspectos, a roupa se caracteriza como isolante térmico interferindo, assim, na troca térmica do ser humano, entre o corpo e o ambiente. O corpo revestido pela vestimenta pode garantir que não haja troca térmica quando a necessidade é evitar a troca de calor com o ambiente. Porém, quando há essa necessidade, a vestimenta inadequada prejudica o balanço térmico. A Norma Internacional ISO 9920:2007 identifica os valores de isolamento térmico e resistência do vapor d’água das vestimentas. Esses valores, baseados em pesquisas em manequim estático e em condições padronizadas, são utilizados como Índice de Isolamento Térmico de Vestimentas como uma das variáveis que interferem no conforto térmico. Porém algumas pesquisas apontam que pode haver imprecisões nos valores tabelados pela ISO 9920, considerando que esta seja uma variável subjetiva podendo apresentar variabilidade muito maior nos padrões de ocupantes em situações reais comparando-as com as roupas padronizadas utilizadas em laboratórios, as quais têm a média de valores utilizada no cálculo do Voto Médio Estimado. Nesse contexto, essa pesquisa objetivou verificar a existência de imprecisões nos valores tabelados pela ISO 9920 do Índice de Isolamento Térmico da Vestimenta através de duas metodologias estatísticas propostas utilizando como banco de dados uma pesquisa de campo em ambiente industrial do setor metal-mecânico. Conclui-se que para esse ramo de atividade o modelo de conforto térmico apresentou-se eficiente. Entretanto, a variação do conjunto de vestimentas foi baixa, não sendo suficiente para gerar questionamentos quanto aos valores tabelados. Conclui-se também que as imprecisões significativas nos valores de Isolamento Térmico de Vestimenta e, discrepâncias entre o Voto Médio Estimado e as Sensações Térmicas Reais podem ser derivadas da não caracterização correta da roupa. Por isso, a complexidade do conjunto de vestimenta é fator relevante para o conforto térmico. / Clothing is one of those items considered as personal protective equipment for working environments. Among different features, clothing is characterized as thermal insulator interfering, therefore, in the thermal exchange between body and environment. The human body with the clothes on can assure it does not allow thermal exchange when it is necessary to avoid the heat exchange with the environment. However, when this exchange is needed, the inadequate clothing affects the thermal balance. The International Standard ISO 9920 identifies the set of garments with an adequate thermal insulation, considering the insulation itself and the water vapor resistance. The values established in the International Standard, based on researches on static mannequin and on standardized conditions, are used as index for Thermal Insulation of Clothing as one of the variables that affect the thermal comfort. Nevertheless, some studies point out that there may be inaccuracies in the values tabulated by ISO 9920, whereas this is a subjective variable and may have greater variability for the user patterns in real situations compared with the standardized clothes used in laboratories, which have the average values used calculated by the Predicted Mean Vote. In this context, this study had the objective of verifying the existence of inaccuracies in the values tabulated by ISO 9920 of the index of Thermal Insulation of Clothing through two statistical methodologies proposed, using as database a field research in an industrial environment of the metal-mechanic sector. It was concluded that the significant inaccuracies in the values of the clothing thermal insulation and the discrepancies between the Predicted Mean Vote and real thermal sensations can be derived from a lack of characterization of the clothes. Therefore, the garment complexity set is a relevant factor for the thermal comfort.
189

Avaliação da concordância entre diferentes termômetros na aferição da temperatura corporal de crianças

Freitas, Ariel Azambuja Gomes de January 2011 (has links)
Introdução: especula-se que os instrumentos e produtos químicos em cuja composição esteja o mercúrio sejam banidos para o uso comercial ou industrial devido à toxicidade deste metal ao meio ambiente e aos seres vivos. Como no nosso meio usa-se predominantemente o termômetro axilar de mercúrio para aferir a temperatura corporal, se de fato este termômetro deixar de ser usado, precisamos saber qual(is) termômetro(s) poderá(ão) substitui-lo; recentemente foram postos no mercado os termômetros eletrônicos instantâneos, como o auricular e o cutâneo frontal e já existia há mais tempo o axilar eletrônico; estes termômetros são confiáveis para substituírem os de mercúrio? Objetivo: avaliar a concordância entre os termômetros eletrônicos axilar e instantâneos (auricular e cutâneo frontal) com os termômetros eletrônico retal e axilar de mercúrio, este com três e cinco minutos de permanência, na aferição da temperatura corporal de crianças. Métodos: foi realizado um estudo transversal com amostra de conveniência de crianças internadas ou em consulta nas áreas pediátricas do Hospital de Clínicas de Porto Alegre. Foi aferida a temperatura corporal dos pacientes participantes do estudo com a utilização quase simultânea de cinco tipos de termômetros: axilar de mercúrio, axilar eletrônico, cutâneo frontal eletrônico, auricular eletrônico e termômetro retal eletrônico. O termômetro axilar de mercúrio foi avaliado com tempo de permanência de três e de cinco minutos. Os dados foram sumarizados em média e desvio padrão. Foi empregado o teste de Bland e Altman para avaliar a concordância entre os termômetros. Resultados: foram avaliadas 20 crianças febris e 43 eutérmicas, com idades entre um mês e dois anos incompletos, totalizando 633 aferições da temperatura corporal. A idade média dos participantes foi 7,5 meses (DP 5,7 meses), 55% deles eram do sexo masculino. Nenhuma criança foi rejeitada e também não houve recusa por parte dos responsáveis em autorizar a participação no estudo. O estudo mostrou que houve boa concordância entre os termômetros axilar de mercúrio aos três minutos e axilar eletrônico, com média das diferenças das temperaturas (MDT) de -0,027°C e intervalo de confiança de 95% (IC95%) de -0,062°C a 0,116°C; entre os termômetros eletrônico retal e axilar de mercúrio aos três minutos, com MDT de 0,096°C e IC95% de -0,175°C a 0,211ºC; e entre os termômetros eletrônico retal e axilar de mercúrio aos cinco minutos, com MDT de 0,038°C e IC95% de -0,149°C a 0,073°C. Houve apenas concordância parcial entre os termômetros eletrônicos retal e axilar, com MDT de -0,123°C e IC95% de 0,030°C a -0,245°C. Conclusões: os resultados indicaram o termômetro axilar eletrônico como o de melhor concordância nas aferições da temperatura corporal de crianças com hipertermia ou normotermia quando comparado com os termômetros axilar de mercúrio e eletrônico retal. Os termômetros eletrônicos instantâneos (auricular e cutâneo frontal) não mostraram boa concordância com termômetro eletrônico retal nem com o termômetro axilar de mercúrio. / Introduction: It is said that chemical products and instruments whose composition have mercury will be banned for commercial or industrial use due to the toxicity of this metal for the environment and beings. Since in our field the axillary mercury thermometer is mainly used for reading the body temperature, and if this thermometer is really banned, we need to know what thermometer(s) will replace it; recently, we can find instant electronic thermometers such as the ear and frontal ones in the market, and for longer, there have been the axillary electronic thermometer; are these thermometers reliable to replace the mercury one? Objective: to evaluate the agreement of the axillary electronic and instant (ear and frontal) thermometers with the rectal electronic and axillary mercury thermometers, the axillary mercury one staying three to five minutes, when reading the body temperature of children. Method: A transversal study was carried out with convenience sampling of hospitalized children or children with medical appointments in the pediatric areas of Hospital de Clínicas de Porto Alegre. The body temperature of the subject patients was taken with the use, almost simultaneously, of five types of thermometers: axillary mercury, axillary electronic, frontal electronic, ear electronic and rectal electronic. The axillary mercury thermometer was evaluated by staying three to five minutes. The data was stated by average and standard deviation. The Bland-Altman test was applied to evaluate the agreement between the thermometers. Result: 20 feverish children and 43 euthermic children, between the ages of one month to two incomplete years, were evaluated, totaling 633 body temperatures taken. The average age of the subjects was 7.5 months (5.7 standard deviation), 55% were male. No child was rejected and there was also no refusal by the responsible for the children to authorize their participation in the study. The study has shown that there is a good agreement between the axillary mercury thermometer at three minutes and the axillary electronic one, with an average of difference in temperature of -0.027°C and confidence interval of 95% (95%CI) of -0.062°C to 0.116°C; between the rectal electronic thermometer and the axillary mercury one at three minutes, with an average of difference in temperature of 0.096°C and 95%CI of -0.175°C to 0.211°C; and between the rectal electronic thermometer and the axillary mercury one at five minutes, with an average of difference in temperature of 0.038°C and 95%CI of 0.149°C to 0.073°. There was only partial agreement between the rectal and axillary electronic thermometers, with an average of difference in temperature of -0.123°C and 95%CI of 0.030°C and -0.245°C. Conclusion: the results have shown that the electronic axillary thermometer has the best agreement in reading the body temperature of children with hyperthermia or normothermia when compared with the axillary mercury and electronic rectal thermometers. The instant electronic thermometers (ear and frontal) have not shown good agreement with either the rectal electronic thermometer or the axillary mercury thermometer.
190

Avaliação da concordância entre diferentes termômetros na aferição da temperatura corporal de crianças

Freitas, Ariel Azambuja Gomes de January 2011 (has links)
Introdução: especula-se que os instrumentos e produtos químicos em cuja composição esteja o mercúrio sejam banidos para o uso comercial ou industrial devido à toxicidade deste metal ao meio ambiente e aos seres vivos. Como no nosso meio usa-se predominantemente o termômetro axilar de mercúrio para aferir a temperatura corporal, se de fato este termômetro deixar de ser usado, precisamos saber qual(is) termômetro(s) poderá(ão) substitui-lo; recentemente foram postos no mercado os termômetros eletrônicos instantâneos, como o auricular e o cutâneo frontal e já existia há mais tempo o axilar eletrônico; estes termômetros são confiáveis para substituírem os de mercúrio? Objetivo: avaliar a concordância entre os termômetros eletrônicos axilar e instantâneos (auricular e cutâneo frontal) com os termômetros eletrônico retal e axilar de mercúrio, este com três e cinco minutos de permanência, na aferição da temperatura corporal de crianças. Métodos: foi realizado um estudo transversal com amostra de conveniência de crianças internadas ou em consulta nas áreas pediátricas do Hospital de Clínicas de Porto Alegre. Foi aferida a temperatura corporal dos pacientes participantes do estudo com a utilização quase simultânea de cinco tipos de termômetros: axilar de mercúrio, axilar eletrônico, cutâneo frontal eletrônico, auricular eletrônico e termômetro retal eletrônico. O termômetro axilar de mercúrio foi avaliado com tempo de permanência de três e de cinco minutos. Os dados foram sumarizados em média e desvio padrão. Foi empregado o teste de Bland e Altman para avaliar a concordância entre os termômetros. Resultados: foram avaliadas 20 crianças febris e 43 eutérmicas, com idades entre um mês e dois anos incompletos, totalizando 633 aferições da temperatura corporal. A idade média dos participantes foi 7,5 meses (DP 5,7 meses), 55% deles eram do sexo masculino. Nenhuma criança foi rejeitada e também não houve recusa por parte dos responsáveis em autorizar a participação no estudo. O estudo mostrou que houve boa concordância entre os termômetros axilar de mercúrio aos três minutos e axilar eletrônico, com média das diferenças das temperaturas (MDT) de -0,027°C e intervalo de confiança de 95% (IC95%) de -0,062°C a 0,116°C; entre os termômetros eletrônico retal e axilar de mercúrio aos três minutos, com MDT de 0,096°C e IC95% de -0,175°C a 0,211ºC; e entre os termômetros eletrônico retal e axilar de mercúrio aos cinco minutos, com MDT de 0,038°C e IC95% de -0,149°C a 0,073°C. Houve apenas concordância parcial entre os termômetros eletrônicos retal e axilar, com MDT de -0,123°C e IC95% de 0,030°C a -0,245°C. Conclusões: os resultados indicaram o termômetro axilar eletrônico como o de melhor concordância nas aferições da temperatura corporal de crianças com hipertermia ou normotermia quando comparado com os termômetros axilar de mercúrio e eletrônico retal. Os termômetros eletrônicos instantâneos (auricular e cutâneo frontal) não mostraram boa concordância com termômetro eletrônico retal nem com o termômetro axilar de mercúrio. / Introduction: It is said that chemical products and instruments whose composition have mercury will be banned for commercial or industrial use due to the toxicity of this metal for the environment and beings. Since in our field the axillary mercury thermometer is mainly used for reading the body temperature, and if this thermometer is really banned, we need to know what thermometer(s) will replace it; recently, we can find instant electronic thermometers such as the ear and frontal ones in the market, and for longer, there have been the axillary electronic thermometer; are these thermometers reliable to replace the mercury one? Objective: to evaluate the agreement of the axillary electronic and instant (ear and frontal) thermometers with the rectal electronic and axillary mercury thermometers, the axillary mercury one staying three to five minutes, when reading the body temperature of children. Method: A transversal study was carried out with convenience sampling of hospitalized children or children with medical appointments in the pediatric areas of Hospital de Clínicas de Porto Alegre. The body temperature of the subject patients was taken with the use, almost simultaneously, of five types of thermometers: axillary mercury, axillary electronic, frontal electronic, ear electronic and rectal electronic. The axillary mercury thermometer was evaluated by staying three to five minutes. The data was stated by average and standard deviation. The Bland-Altman test was applied to evaluate the agreement between the thermometers. Result: 20 feverish children and 43 euthermic children, between the ages of one month to two incomplete years, were evaluated, totaling 633 body temperatures taken. The average age of the subjects was 7.5 months (5.7 standard deviation), 55% were male. No child was rejected and there was also no refusal by the responsible for the children to authorize their participation in the study. The study has shown that there is a good agreement between the axillary mercury thermometer at three minutes and the axillary electronic one, with an average of difference in temperature of -0.027°C and confidence interval of 95% (95%CI) of -0.062°C to 0.116°C; between the rectal electronic thermometer and the axillary mercury one at three minutes, with an average of difference in temperature of 0.096°C and 95%CI of -0.175°C to 0.211°C; and between the rectal electronic thermometer and the axillary mercury one at five minutes, with an average of difference in temperature of 0.038°C and 95%CI of 0.149°C to 0.073°. There was only partial agreement between the rectal and axillary electronic thermometers, with an average of difference in temperature of -0.123°C and 95%CI of 0.030°C and -0.245°C. Conclusion: the results have shown that the electronic axillary thermometer has the best agreement in reading the body temperature of children with hyperthermia or normothermia when compared with the axillary mercury and electronic rectal thermometers. The instant electronic thermometers (ear and frontal) have not shown good agreement with either the rectal electronic thermometer or the axillary mercury thermometer.

Page generated in 0.0697 seconds