• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 301
  • 56
  • 10
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 425
  • 425
  • 230
  • 136
  • 95
  • 94
  • 92
  • 84
  • 78
  • 75
  • 71
  • 71
  • 71
  • 62
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Resistência de união entre o titânio fundido e cimentos resinosos, comparada com a de uma liga de níquel-cromo. / Tensile bond strength of titanium and a nickel-chromium alloy cemented with resin cements.

França, Rodrigo de Oliveira 29 August 2000 (has links)
O objetivo da pesquisa foi avaliar a resistência de união entre o titânio fundido e cimentos resinosos, comparada com a de uma liga de níquel-cromo. Os fatores estudados foram: cimentos (Enforce, Cimento de resina 3M, Cement-it); conjugação liga/ revestimento ( titânio obtido com revestimento com a case e sem a case e liga de níquel-cromo, com fosfatado); tratamento superficial ( jateamento com óxido de alumínio e sistema Siloc); desgaste (cimentação antes do desgaste e depois). Para os espécimes foram obtidos discos por fundição, que foram jateados com óxido de alumínio. A metade foi cimentada depois desse tratamento e outra após a aplicação do Siloc. A armazenagem foi por 5 dias fazendo-se termociclagem (1.000 ciclos). Após o rompimento dos espécimes, por ensaio de tração, as superfícies cimentadas foram desgastadas com lixa n o 200 e novamente cimentadas. As conclusões foram: houve grande diferença entre cimentos; o titânio e o níquel-cromo nas devidas condições apresentaram retentividades semelhantes; o Siloc aumentou muito a retenção; o desgaste só influiu um pouco no titânio a case. / The Purpose of the research was to evaluate tensile bond strength of cemented titanium and nickel-chromium alloy cast discs. Factors studied were: Cements (Enforce, Resin cement 3M, Cement-it); Combination alloy/investment ( titanium obtained with a case and without a case investments, and nickel-chromium alloys); surface treatment (sandblasting with Al2O3 and Siloc application): surface abrading (test before and after).Cast discs with fixing stem were sandblasted and half of them were luted in this stage and the other one were luted after Siloc treatment. Specimens were stored for 5 days and thermalcycled (1,000 cycles). After tensile strength test surfaces were abraded and discs were luted again. The conclusions were: cements presented different bond strength; titanium and nickel-chromium alloy, under given condition, presented similar strength; Siloc system presented at least double strength; abrading of a case, titanium enhance only a little bond strength.
102

Estudo da distribuição de tensões e da resistência à tração de interfaces adesivas dentina-resina de duas formas de espécimes submetidos a diferentes protocolos de envelhecimento acelerado / Study of stress distribution and tensile bond strength of dentin-resin adhesive interfaces of two types of specimens submitted to different protocols of accelerated aging

Sanches, Luciana Katty Figueiredo 08 July 2011 (has links)
O acelerado e freqüente desenvolvimento de novos materiais e técnicas restauradoras tornam necessárias avaliações rápidas que estimem seus desempenhos clínicos. Este estudo avaliou protocolos de envelhecimento acelerado, in vitro, capazes de simular o desempenho de restaurações adesivas frente aos desafios inerentes ao ambiente oral. Foram utilizados 36 molares hígidos, cortados ao meio e divididos aleatoriamente em 12 grupos. Em todos os grupos foi realizada a exposição da superfície dentinária, delimitação da área de adesão e condicionamento ácido da superfície, seguida a aplicação do Sistema Adesivo Scotchbond Multiuso, e colocação da resina composta Z100, em incrementos. Foram confeccionados 6 grupos em formato de palito e 6 grupos em formato de haltere: dois grupos não foram submetidos à ciclagem térmica e mecânica (STSM-P e STSM-H); outros dois foram submetidos à ciclagem térmica (1.000 ciclos; 5-55ºC; 1min em cada banho) e não a mecânica (CTSM-P e CTSM-H); dois ainda foram submetidos à ciclagem mecânica com dispositivo Nova Ética e não a térmica (STNE-P e STNE-H); dois foram submetido à ciclagem mecânica com dispositivo Nova Ética (500.000 ciclos), acrescido de ciclagem térmica (CTNE-P e CTNE-H); outros dois por fim, foram submetidos à ciclagem mecânica por Microrotação (105 ciclos, aproximadamente por 7 horas), e não a térmica (STMR-P e STMR-H); por fim os dois últimos grupos foram submetido à ciclagem mecânica por Microrotação acrescido de ciclagem térmica (CTMR-P e CTMR-H). Todos os grupos foram preparados para teste de microtração. Com as medidas de resistência de união dos palitos e halteres de cada dente foi realizada análise de variância e teste de Tukey. A interação tripla Formato -FORM- (Palito ou haltere) X Ciclagem Térmica- T- (Com e Sem) X Ciclagem Mecânica-M- (Nova Ética e Microrotação) não foi significante (p=0,698), bem como a interação 2 a 2 dos mesmos fatores: FORMxT (p=0,391); TxM (p=0,477); FORM x M (p=0,746). O fator Formato do espécime (Palito ou Haltere) teve diferença extremamente significante (p=0,000), sendo que os valores dos halteres foram maiores que os dos palitos. O fator Ciclagem Térmica (Com e Sem) não foi estatisticamente significante (p=0,2), bem como o fator Ciclagem Mecânica (Nova Ética e Microrotação) (p=0,587). Pode-se concluir que: a ciclagem térmica, bem como as ciclagens mecânicas sistema Nova Ética e Microrotação não foram capazes de reduzir significativamente os valores de resistência de união das interfaces adesivas, nem quando aplicadas isoladamente, nem quando associadas; os espécimes com formato de palito apresentaram valores de resistência de união menores do que os em formato de haltere; não foi possível estabelecer nenhum padrão de degradação entre os grupos através da microscopia eletrônica de varredura; os elementos finitos identificaram uma distribuição mais homogênea das tensões geradas na interface dos espécimes em formato de haltere. / The rapid and frequent development of new materials and restorative techniques necessitate rapid assessments to estimate their clinical outcomes. This study sought to evaluate protocols for accelerated aging, in vitro, capable of simulating the performance of adhesive restorations with challenges inherent to the oral environment. The study included 36 molars that were randomly divided into 12 groups. In all groups were exposed dentin surface, defining the area of adhesion and etching the surface, then the application of Scotchbond Multipurpose Adhesive System, and placement of composite resin Z100, in increments. Six groups were fabricated in the shape of sticks and six other groups in dumbbell shape: the first was not subjected to thermal cycling and mechanical (STSM-P and STSM-H), the second was subjected to thermal cycling (10,000 cycles, 5-55 ° C) and not the mechanics (CTSM-P and CTSM-H); the third was subjected to mechanical cycling device with new Ethics (500,000 cycles) and not thermal (STNE-P and STNE-H); the fourth was subjected to mechanical cycling device with new Ethics, plus thermal cycling (CTNE-P and CTNE-H); the fifth was submitted the mechanical cycling device for Microrotation (105 cycles), but not thermal (STMR-P and STMR-H) and finally the sixth was subjected to mechanical cycling device for Microrotation plus thermal cycling (CTMR-P and CTMR-H). All groups were prepared for microtensile bond-strength test. With the measures of bond strength of each tooth was performed statistical analysis (ANOVA and Tukey test). Random samples of specimens were evaluated by SEM. The triple interaction format (stick or dumbbell-shaped) X Thermal cycling (with and without) X Cycling Mechanics (New Ethics and Microrotation) was not significant (p = 0.698), as well as the interaction 2-2 of the same factors: FORMXT (p = 0.391); TXM (p = 0.477); FORMxM (p = 0.746). With regard to factor Format specimen is observed that the bond strength values obtained for the dumbbell-shaped are higher than those obtained for the sticks (p = 0.000). With regard to factor Thermal cycling was observed that the difference was not statistically significant (p = 0.2). As for factor Cycling Mechanics, the values of groups without cycling were very similar to those obtained in groups cycled through the system New Ethics, and the system by Microrotation, no significant difference between any of them (p = 0.587). The conclusions were that the stick-shaped specimens showed values of bond strength lower than the dumbbell-shaped; thermocycling and mechanical cycling were not able to significantly reduce the values of bond strength of adhesive interfaces, even when applied alone or when associated. It could not be establish any pattern of degradation among the groups by SEM; the finite element identified a more homogeneous distribution of stresses generated at the interface of dumbbell shaped specimens.
103

Bond Behavior of Fiber Reinforced Polymer Bars Under Hinged Beam Conditions

Sandstrom, Ryan James 01 January 2011 (has links)
The research provided in this report examines the behavior of fiber reinforced polymer (FRP) reinforcing bars, embedded in normal weight concrete (NWC) hinged beam-end specimens, tested in accordance with two laboratory conditions. Reinforcing bars of different diameter, material configuration, and finished surface preparation were tested for bond strength parameters determined in accordance with ACI Committee Report 440.3. Bond strength parameters under the first condition were tested within NWC beams at a relatively low compressive strength and minimum embedment length; the second condition allowed testing within NWC beams at twice the design compressive strength of the first condition and moderate embedment length. The load-slip curves developed show the differences that occur under the specified conditions. The influence of embedment length, bar diameter, material configuration, finished surface preparation, and concrete compressive strength are reported in detail. Furthermore, the testing arrangement selected for this study was proven to have a significant influence on bond behavior when compared to conventional pullout test methods.
104

Laser keyhole welding for microlaminating a high-temperature microchannel array

Lajevardi, Babak 14 September 2012 (has links)
Microchannel process technology (MPT) components are chemical unit operations which exploit highly-parallel arrays of microchannels to process large fluid volumes for portable and distributed applications. Microchannel heat exchangers (MCHXs) have demonstrated 3 to 5 times higher heat fluxes when compared to conventional heat exchangers resulting in proportionate reductions in size and weight. The most common fabrication approach for producing MPT components is microchannel lamination, or microlamination, in which thin layers of metal or polymer are patterned with microchannel features, registered, and bonded to produce monolithic components. Currently, the most common microlamination architecture involves the photochemical machining and diffusion bonding of metal foils. Prior work has established that the yields in diffusion bonding often drive the costs of MCHXs. Laser keyhole welding has been proposed as an alternative bonding technology providing the potential for faster cycle times, smaller weld widths and layer-to-layer evaluation of hermeticity leading to higher yields. Furthermore, laser weldments have small heat-affected zones providing excellent mechanical strength. In this study, efforts are made to evaluate the feasibility of using laser welding in the microlamination of a high-temperature counter-flow heat exchanger made of a Ni superalloy. Preliminary efforts were focused on the development and validation of weld strength estimation models. These models were then used to narrow down the range of process parameters and a final set of process parameters was determined through the use of a full factorial experiment with weld strength, joining efficiency and weld gap as response variables. The most acceptable parameter set was used to demonstrate the fabrication of a Haynes 214 microchannel array with adequate bond strength and hermeticity and minimal thermal warpage. / Graduation date: 2013
105

Influência da presença de um filme fino de platina na resistência de união titânio-cerâmica

Rodrigues, Flávia Pires [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T19:16:39Z : No. of bitstreams: 1 rodrigues_fp_me_guara.pdf: 4184618 bytes, checksum: edb4c6c9b5b186971c9e548252d87136 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Problemas com a resistência de união metal-cerâmica têm sido encontrados quando o titânio é utilizado em Odontologia. A proposta deste estudo foi aumentar a resistência na interface titânio-cerâmica pela aplicação de um filme fino de platina na superfície do titânio, por meio da utilização da técnica de deposição por pulverização catódica. Dez padrões (1.0 x 4.0 x 30 mm) foram obtidos por meio de cortes de placas de resina acrílica e incluídos em um revestimento à base de zircônia. As fundições de titânio para preenchimento dos moldes foram realizadas em uma máquina de fundição centrífuga. As amostras foram lixadas até as dimensões finais (0.50 x 3.0 x 30 mm) para a remoção da camada -case e jateadas com pó de alumina (grupo controle) e de dióxido de titânio (grupo experimental). Uma cerâmica de ultrabaixa temperatura de fusão foi aplicada no centro da superfície (8.0 x 1.0 x 3 mm). A resistência de união foi determinada pelo teste de flexão de três pontos em uma máquina universal de ensaios com uma velocidade de 0,5mm/min. As amostras foram analisadas por meio de microscopia óptica e microscopia eletrônica de varredura antes e após os ensaios mecânicos. Os resultados revelaram valores maiores de união entre o titânio e a cerâmica quando o filme de platina foi aplicado (25,70 l 4,54 MPa), mas não houve diferença estatística significante em relação ao grupo controle (24,32 l 3,11 MPa), o que indica que o primeiro grupo também possui uma resistência de união suficiente para uso clínico. / Problems with metal-ceramic bond strength have been encountered when titanium is used in prosthetic dentistry. The purpose of this study was increase the bond strength of titanium-ceramic interface applying a platinum film on the titanium surface using DC-sputtering deposition technique. Ten 1.0 x 4.0 x 30 mm patterns were cut from sheet of acrylic resin and invested in a zirconia-based investment material. Titanium castings were made using a centrifugal casting machine. Specimens were grinded to final dimensions (0.50 x 3.0 x 30 mm) to remove the -case layer and blasted with alumina (control group) and titanium dioxide (experimental group) powders. An ultra low-fusing dental ceramic was applied to the center of the surface (8.0 x 1.0 x 3 mm). The bond strength was determined by three-point bending test. at a universal testing machine with a loading rate of 0,5mm/min.The samples were analyzed using Optical Microscopy and Scanning Electron Microscopy before and after the mechanical testing.The results showed greater values of adherence between titanium and ceramic when the platinum film was applied (25,70 l 4,54 MPa), but there were no statistic differences to those of the controls (24,32 l 3,11 MPa) that indicates that the first one has also sufficient bond strength for clinical use.
106

Avaliação de tratamentos de superfície em diferentes sistemas cerâmicos e seu efeito na resistência de união a um cimento resinoso

Ribeiro, João Gustavo Rabelo [UNESP] 03 March 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-03-03Bitstream added on 2014-06-13T19:16:51Z : No. of bitstreams: 1 ribeiro_jgr_me_arafo.pdf: 3291389 bytes, checksum: 7433b8057e44c506b548538c7a3e997e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar o efeito de três tratamentos superficiais na resistência de união de um cimento resinoso a três cerâmicas dentais: Duceram Plus (DP), IPS Empress II (IPS) e In-Ceram Alumina (INC), e analisar a topografia superficial dessas cerâmicas submetidas aos mesmos tratamentos superficiais. Para o teste de resistência de união foram confeccionadas 18 amostras de cada material (7,5mm de diâmetro x 3,0mm de espessura), incluídas em resina acrílica e polidas até lixa nº 600. As amostras foram divididas em três grupos: a) jateamento com partículas de óxido de alumínio de 50 æm; b) condicionamento com ácido fluorídrico 10%; c) associação de a e b. As amostras foram lavadas e secas. A área de adesão da cerâmica foi delimitada com matriz metálica perfurada (5,0mm de diâmetro e 3,0mm de espessura). Foi aplicado silano, adesivo e cimento resinoso Variolink II, fotoativado por 40 segundos. As amostras receberam 1000 ciclos térmicos de 5 a 55°C. O ensaio de cisalhamento foi realizado em máquina de ensaios MTS 810, com célula de carga de 10 kN e velocidade de 0,5 mm/min. Para a topografia superficial foram confeccionados um coping de IPS, um do INC e uma coroa de DP, seguindo as recomendações dos fabricantes. Cada coping ou coroa foi cortado com disco diamantado em quatro partes: uma delas não recebeu nenhum tratamento, e as demais receberam um dos tratamentos acima descritos. Fotomicrografias foram obtidas por meio de microscopia eletrônica de varredura e a análise foi feita de acordo com a característica da superfície. Pode-se concluir que: o tratamento associado não ofereceu vantagens em relação ao condicionamento ácido, para os materiais DP e IPS; para o INC o tratamento associado não ofereceu vantagens em relação ao jateamento. A DP e o IPS apresentaram resultados melhores em relação ao INC, independentemente dos tratamentos... / The aim of this study was to evaluate the effect of three surface treatments on the shear bond strength of a resin luting cement to three ceramics materials: Duceram Plus (DP), IPS Empress II (IPS) and In-Ceram Alumina (INC), and to assess its surface topography after these treatments. Eighteen specims were fabricated to each material (7,5 mm in diameter x 3,0 mm in thickness), embebed in acrylic resin and ground up to 600 grit. The specims were randomly divided into 3 groups of 6 specims: (a) airborne particle abrasion with 50 æm aluminum oxide; (b) 10% hydrofluoric acid etching; (c) a and b treatments. The specims were cleaned and dried. Silane, adhesive and resin luting cement Variolink were applied in 5,0 mm in diameter and 3,0 mm height to ceramic surface and then light cured. All specims were termocycled (1000, 5-55°C). The shear bond strength was then measured in a testing machine MTS 810, at a crosshead speed of 0,5 mm/min. To asses the surface topography, one coping each of IPS and INC, and a DP crown were fabricated following the manufacturer's instructions. Each coping or crown was sectioned into 4 equal parts by a diamond disk. One part didn't receive any treatment, and the others, received treatments as above described. Photomicrographs were obtained by a SEM, and the superficial characteristic was described. In conclusion, the associate treatment didn't offer advantages in relation to the acid etching, for DP and IPS; for INC the associate treatment didn't offer advantages in relation to the airborne. DP and IPS presented the best results, independently of the superficial treatments. The photomicrographs showed compatible correlation of the superficial characteristic with the bond strength values.
107

Resistência de união de cimentos resinosos, ao cisalhamento, variando o substrato e o material restaurador

Ariki, Eurípedes Kaizo [UNESP] 19 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-19Bitstream added on 2014-06-13T20:58:49Z : No. of bitstreams: 1 ariki_ek_me_sjc.pdf: 497007 bytes, checksum: 903e217ecb5b3b29845a544edd5e4640 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a resistência de união ao cisalhamento de três diferentes tipos de agentes cimentantes: auto-condicionante (Panavia F / P), convencional (RelyX ARC - R) e auto-adesivo (RelyX U100 - U), usando dois tipos de substratos (esmalte / E e dentina / D) e dois tipos de materiais restauradores (cerâmica - C e resina composta laboratorial - R). Foram utilizados cento e vinte incisivos bovinos incluídos em resina acrílica, de modo que uma parte da face vestibular ficasse exposta. Os dentes foram desgastados até se obter uma área lisa e plana, de aproximadamente de 25 mm2, em metade dos espécimes foi exposto esmalte, na outra metade dentina. Uma fita adesiva com um orifício no centro com 3 mm de diâmetro foi colada sobre estas áreas, delimitando a área a ser usada no teste. Foram confeccionados sessenta cilindros de cerâmica a base de dissilicato de lítio (IPS e.max) e sessenta cilindros de resina composta (SR Adoro) com dimensões de 3mm de diâmetro e 3mm de altura. Os cilindros foram cimentados aos substratos com os três tipos de cimento resinoso, formando doze grupos experimentais: G1(PEC); G2(PER); G3(PDC); G4(PDR); G5(REC), G6(RER); G7(RDC); G8(RDR): G9(UEC); G10(UER); G11(UDC) e G12(UDR). Após um período de uma semana, os corpos-de-prova foram levados à máquina de ensaios universais para a realização do teste de cisalhamento com velocidade de 0,5 mm/min. Os resultados (foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey em nível de 5% de significância. Verificou-se que o maior valor médio obtido foi do G5 (17,46 MPa) diferindo significativamente dos demais grupos, exceto do G1 (14,60 MPa). O G12 (1,03 MPa) apresentou o menor valor de resistência, não apresentando semelhança estatística com os outros grupos. A adesão em esmalte... / The aim of the present study was to evaluate the shear bond strength of three types of luting agents: self-etching (Panavia F, P), conventional (Rely X ARC, R) and self-adhesive (Rely X U100, U), using enamel (E) or dentin (D) as substrates and two types of restorative materials (ceramic, C and laboratorial composite, R). One hundred and twenty-five bovine incisors were embedded in acrylic resin leaving their bucal side exposed. The teeth were ground flat until a 5mm2 area was created. Half of the specimens had enamel exposed and the other half had dentin exposed. A piece of tape with a 3 mm hole was used to delimitate the bonding area. Sixty cylinders of ceramic (IPS E.max Press) and sixty of composite (SR Adoro), 3 mm in diameter and 3 mm in height, were confectioned. The cylinders were luted to the substrates, forming twelve groups: G1 (PEC); G2 (PER); G3 (PDC); G4 (PDR); G5 (REC), G6 (RER); G7 (RDC); G8(RDR): G9 (UEC); G10(UER); G11(UDC) and G12(UDR). After one week, the specimens were subjected to a shear test in a universal testing machine at a crosshead speed of 0,5 mm/min. The results were submitted to both the Anova and Tukey tests (p<0.05) for statistical analysis. It was observed that the mean of G5 (17,46 MPa) was significantly different from the other groups means, except for G1 (14,60 MPa). Statistically G12 (1,03) had the lowest bond strength differing from the other groups. Bondings between was ceramic and enamel determined the highest bond strength for all luting agents. Due to the low bond strength and the failures between cement and substrate, using the self-adhesive cement and laboratorial composite to make bonds is not advisable.
108

Avaliação da resistência adesiva e da atividade antimicrobiana de diferentes sistemas de colagem de bráquetes associados à clorexidina e ao flúor

Ribeiro, Jorge Luís de Oliveira January 2006 (has links)
121f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T18:12:49Z No. of bitstreams: 2 Dissertacao Jorge Ribeiro2.pdf: 5452461 bytes, checksum: 42c5f38b042e314e1265214af3e8f68c (MD5) Dissertacao Jorge Ribeiro1.pdf: 51427 bytes, checksum: 32ae2c485acbca7fce04dfdc7745eaf0 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T12:02:53Z (GMT) No. of bitstreams: 2 Dissertacao Jorge Ribeiro2.pdf: 5452461 bytes, checksum: 42c5f38b042e314e1265214af3e8f68c (MD5) Dissertacao Jorge Ribeiro1.pdf: 51427 bytes, checksum: 32ae2c485acbca7fce04dfdc7745eaf0 (MD5) / Made available in DSpace on 2013-05-08T12:02:54Z (GMT). No. of bitstreams: 2 Dissertacao Jorge Ribeiro2.pdf: 5452461 bytes, checksum: 42c5f38b042e314e1265214af3e8f68c (MD5) Dissertacao Jorge Ribeiro1.pdf: 51427 bytes, checksum: 32ae2c485acbca7fce04dfdc7745eaf0 (MD5) Previous issue date: 2006 / O objetivo deste estudo in vitro foi avaliar a influência da incorporação de clorexidina e flúor na resistência adesiva e na atividade antimicrobiana de diferentes sistemas de colagem de bráquetes (Sistema Transbond XT / 3M-Unitek e Sistema Enlight / Ormco) cujos respectivos adesivos foram pré misturados ao verniz de flúor (Fluor Protector / Ivoclar- Vivadent) e/ou verniz de clorexidina (Cervitec / Ivoclar-Vivadent). A amostra utilizada foi constituída por pré-molares humanos, extraídos por indicações ortodônticas e divididos em oito grupos experimentais: G1 – Sistema Transbond XT conforme prescrito pelo fabricante; G2 – Sistema Transbond XT associado a verniz de clorexidina; G3 – Sistema Transbond XT associado a verniz de flúor; G4 – Sistema Transbond XT associado, simultaneamente, aos vernizes de clorexidina e flúor; G5 – Sistema Enlight conforme prescrito pelo fabricante; G6 - Sistema Enlight associado a verniz de clorexidina; G7 - Sistema Enlight associado a verniz de flúor; G8 - Sistema Enlight associado, simultaneamente, aos vernizes de clorexidina e flúor. A avaliação da resistência adesiva foi realizada pelo teste de cisalhamento; também foi realizada a observação do Índice de Adesivo Remanescente (IAR) na superfície do esmalte dental, após a descolagem dos bráquetes. Além disso, os corpos-de-prova foram submetidos à ciclagem de pH, visando simular desafio cariogênico e, também foram incluídos em meios de cultura contendo Staphylococcus aureus, a fim de avaliar a possibilidade desses sistemas de colagem, associados a flúor e/ou clorexidina, proporcionarem proteção à desmineralização do esmalte dental e/ou impedirem o crescimento bacteriano, sobretudo nas áreas localizadas ao redor dos bráquetes. A partir dos resultados obtidos pôde-se concluir que a resistência adesiva não foi alterada, de forma estatisticamente significante, nos grupos experimentais que utilizaram o sistema Transbond XT (G2, G3 e G4), bem como, no grupo que utilizou o sistema Enlight associado ao verniz de clorexidina (G6); já nos grupos que utilizaram o sistema Enlight associado ao verniz de flúor isoladamente (G7) e/ou simultaneamente ao verniz de clorexidina (G8), as resistências adesivas foram reduzidas de forma estatisticamente significante, quando comparados ao respectivo grupo controle (G5). A avaliação do Índice de Adesivo Remanescente (IAR) demonstrou predominância do “escore 3” em todos os grupos experimentais que utilizaram o Sistema Transbond XT e do “escore 2” para todos os grupos experimentais que utilizaram o Sistema Enlight e, portanto, fraturas adesivas na interface adesivo-bráquete e fraturas mistas (adesiva e coesiva), respectivamente. Além disso, observando-se a formação de halos de inibição de crescimento bacteriano nos meios de cultura, 24 horas após a inclusão dos corpos-de-prova, constatou-se que os sistemas adesivos acrescidos unicamente por verniz de clorexidina (G2 e G6) foram os únicos a demonstrarem atividade antimicrobiana de forma estatisticamente significante. Nenhum grupo experimental mostrou-se eficaz na prevenção à desmineralização do esmalte dental após a simulação do desafio cariogênico, através da ciclagem de pH. / Salvador
109

Resistência de união em dentes decíduos erodidos / Microshear bond strength of self-etch and etch-and-rinse adhesives to eroded primary teeth

Santos, Nicole Marchioro dos January 2016 (has links)
O objetivo deste estudo foi avaliar a resistência de união (RU) do esmalte e da dentina decídua após desafio erosivo utilizando sistemas adesivos convencionais e autocondicionantes. Noventa e seis molares decíduos foram seccionados mesio-distalmente para obtenção de blocos de esmalte, foram embebidos em resina epóxi e polidos com lixas de carbeto de silício (600, 1200, 2400 e 4000). As amostras foram randomizadas e divididas entre os 4 sistemas adesivos utilizados: SB (Adper Single Bond 2), SBU (Single Bond Universal), OBFL (Optibond FL) e BF (Bond Force). Metade das amostras (grupo teste, n=48) foram submetidas a desafio erosivo/abrasivo (50 mL de Coca-Cola®, pH 2,6, 1 min, 4x ao dia, 5 dias, seguido de escovação por 1 min com dentifrício fluoretado, NaF 1450 ppm e saliva artificial). A outra metade dos blocos (grupo controle) foi mantida imersa em saliva artificial. Em seguida foram realizadas restaurações de resina flow (Tetric Flow) utilizando matrizes de polivinil siloxano com diâmetro de 0,9mm e 1mm de altura. As amostras foram colocadas na máquina de ensaio universal e foi aplicada força de cisalhamento com velocidade de 1,0mm/min até que a fratura ocorresse. Os mesmos blocos tiveram suas superfícies de dentina expostas, em seguida, as mesmas etapas foram realizadas (restaurações e RU). Foram utilizados os testes ANOVA de duas vias e Tukey (p=0,05). No esmalte, os grupos teste e controle não apresentaram diferença estatística, independentemente dos sistemas adesivos utilizados. Na dentina, o BF apresentou melhores valores de no grupo teste (p=0,04). O fator adesivo foi significativo na análise fatorial (p<0,001) assim como a interação entre desafio erosivo/abrasivo e os sistema adesivo utilizado (p=0,046). Somente o substrato dentinário teve influência significativa na RU (p=0,395). Conclui-se que a RU ao esmalte decíduo não foi afetada pelo desafio erosivo/abrasivo para todos os sistemas adesivos utilizados, enquanto a RU na dentina decídua somente foi afetada pelo sistema adesivo autocondicionante contendo flúor. / The aim of this in vitro study was to evaluate the microshear bond strength of four adhesive systems on eroded or sound primary teeth. Methods: Ninety-six primary molars were cut mesio-distally, embedded, ground and polished with SiC papers (600, 1200, 2400 and 4000). Specimens were randomly divided according to 4 adhesive systems: SB (Adper Single Bond2®), SBU (Universal Single Bond®), OBFL (OptibondFL®) and BF (BondForce®). Half of the specimens were exposed to erosive/abrasive challenge, and the other half (control group; n=48) remained immersed in artificial saliva. Erosive challenge consisted of specimen immersion in Coca-Cola® (pH 2.6, 50ml, 1min, 4x, 5 days). Once a day, the specimens were brushed using an electric toothbrush with a slurry (artificial saliva and NaF toothpaste, 1450 ppm) for 1 minute. Polyvinyl siloxane molds with a perforation 0.9 mm in diameter and 1 mm in height were placed over the specimens in order to build restorations with flowable resin composite. The molds were cut with surgical blades and removed to allow for microshear bond strength testing. Bonded specimens were attached to an universal testing machine and a shear load was applied with a steel wire at a crosshead speed of 1.0 mm/min until failure occurred. After the tests in enamel, dentin was exposed and polished to perform the same tests in this substrate. Two-way ANOVA and Tukey tests were performed (p=0.05). Results: No statistically significant difference was found between the eroded and sound enamel for any of the adhesives. BF was statistically significant better in eroded dentin than sound dentin (p=0.04). A factorial analysis indicated that the factor adhesive was significant (p<0.001) as was the interaction between adhesive and erosive tooth wear (p=0.046). Only the dentin substrate had a significant influence on microshear bond strength (p=0.395). Conclusion: Bond strength to primary enamel was not affected by erosive/abrasive challenge for all the adhesives systems, while in primary dentin the bond strength was affected only after the use of self-etch adhesive containing fluoride.
110

BOND STRENGTH EVALUATION IN ADHESIVE JOINTS USING NDE AND DIC METHODS

Poudel, Anish 01 May 2015 (has links)
Adhesive bonding of graphite epoxy composite laminates to itself or traditional metal alloys in modern aerospace and aircraft structural applications offers an excellent opportunity to use the most efficient and intelligent combination of materials available thus providing an attractive package for efficient structural designs. However, one of the major issues of adhesive bonding is the occasional formation of interfacial defects such as kissing or weak bonds in the bondline interface. Also, there are shortcomings of existing non-destructive evaluation (NDE) methods to non-destructively detect/characterize these interfacial defects and reliably predicting the bond shear strength. As a result, adhesive bonding technology is still not solely implemented in primary structures of an aircraft. Therefore, there is a greater demand for a novel NDE tool that can meet the existing aerospace requirement for adhesive bondline characterization. This research implemented a novel Acoustography ultrasonic imaging and digital image correlation (DIC) technique to detect and characterize interfacial defects in the bondline and determine bond shear strength in adhesively bonded composite-metal joints. Adhesively bonded Carbon Fiber Reinforced Plastic (CFRP) laminate and 2024-T3 Aluminum single lap shear panels subjected to various implanted kissing/weak bond defects were the primary focus of this study. Kissing/weak bonds were prepared by controlled surface contamination in the composite bonding surface and also by improperly mixing the adhesive constituent. SEM analyses were also conducted to understand the surface morphology of substrates and their interaction with the contaminants. Morphological changes were observed in the microscopic scale and the chemical analysis confirmed the stability of the contaminant at or very close to the interface. In addition, it was also demonstrated that contaminants migrated during the curing of the adhesive from CFRP substrate which caused a decrease of bond shear strength in single lap shear test samples. Through-transmission ultrasonics (TTU) Acoustography at 3.8 MHz showed promising results on the detectability of bondline defects in adhesively bonded CFRP-Al lap shear test samples. A correlation between Acoustography ultrasonic attenuation and average bond shear strength in CFRP-Al lap shear panels demonstrated that differential attenuation increased with the reduction of the bond shear strength. Similarly, optical DIC tests were conducted to identify and quantify kissing bond defects in CFRP-Al single lap shear joints. DIC results demonstrated changes in the normal strain (εyy) contour map of the contaminated specimens at relatively lower load levels (15% ~ 30% of failure loads). Kissing bond regions were characterized by negative strains, and these were attributed to high compressive bending strains and the localized disbonding taking placed at the bondline interface as a result of the load application. It was also observed that contaminated samples suffered from more compressive strains (εyy) compared to the baseline sample along the loading direction and they suffered from less compressive strains (εxx) compared to the baseline sample perpendicular to the loading direction. This demonstrated the adverse effect of the kissing bond on the adhesive joint integrity. This was a very significant finding for the reason that hybrid ultrasonic DIC is being developed as a faster, more efficient, and more reliable NDE technique for determining bond quality and predicting bond shear strength in adhesively bonded structures.

Page generated in 0.0707 seconds