• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • Tagged with
  • 17
  • 17
  • 17
  • 9
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do tipo de preparo e sistema adesivo na resistência de união à dentina bovina /

Silva, Melissa Aline da. January 2010 (has links)
Resumo: Este estudo avaliou a resistência de união entre dentina bovina e três sistemas adesivos: um de condicionamento total e dois autocondicionantes, variando-se o tipo de preparo da dentina. Foram utilizados 108 dentes bovinos onde as raízes foram removidas e a dentina coronária vestibular foi exposta. As superfícies foram preparadas com os seguintes métodos: pontas diamantadas de granulação média em turbina de alta rotação, pontas CVD acopladas em aparelho de ultra-som e laser Er:YAG. Os grupos foram subdivididos para aplicação dos seguintes sistemas adesivos de acordo com as recomendações do fabricante: Clearfil SE Bond (Kuraray), Adper SE Plus (3M ESPE), autocondicionantes, e Adper Single Bond 2 (3M ESPE), de condicionamento ácido total. Os espécimes foram restaurados com resina composta Filtek 250 (3M ESPE) com espessura de 4 mm. A resina foi inserida em incrementos de 2 mm e fotopolimerizada por 20 s. Em seguida, os espécimes foram armazenados em água destilada a 37 °C por 24 h e então seccionados em formato de palito com aproximadamente 1mm2 de área na interface adesiva. Foi realizado o teste de microtração em máquina de ensaio universal com velocidade de 1.0 mm/min. Os resultados foram submetidos aos testes estatísticos de análise de variância paramétrica de 2 fatores (ANOVA) e o teste de Tukey empregando um nível de significância de 5% (p<0,05). Espécimes adicionais foram preparados para observação em microscópio eletrônico de varredura. Os resultados mostraram que a ponta CVD obteve menores valores de resistência adesiva, enquanto a ponta diamantada e o laser obtiveram valores semelhantes, porém mais elevados. O sistema adesivo Single Bond obteve valores equivalentes ao Adper SE Plus e significativamente diferentes quando comparados ao sistema adesivo Clearfil SE Bond . O estudo concluiu que o método de preparo e o tipo de sistema adesivo influenciaram na resistência de união / Abstract: The aim of this study was to compare the microtensile bond strength of two self-etching adhesive systems and one total-etching, with different methods of dentin preparation. A hundred and eight bovine teeth, stored in freezer -18ºC, were used. The buccal face dentine was exposed and prepared with three different methods: Diamond tip (DT) with high speed; CVD tip with ultrasound advice (CVD) and Er:YAG laser (LA). Three different adhesive systems were used: Adper Single Bond 2 (SB) (3M ESPE), total etch; Adper SE Plus (AS) (3M ESPE) and Clearfil SE Bond (CS) (Kuraray), both self-etching. After dentin preparation, the adhesives systems were applied according to manufacturer's instructions. Blocks of composite resin (Filtek Z250 - 3M ESPE) with 4 mm high were prepared using the incremental technique. After storage in distilled water for 24h at 37ºC, serial mesio-distal and bucco-lingual cuts were made and stick-like specimens were obtained, with transversal section of 1,0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (Mpa) were subjected to ANOVA and Tukey tests (5%). The results showed lower bond strength in groups prepared with CVD tip. LA and DT groups obtained similar values of bond strength and higher than CVD. The adhesive systems SB and AS showed values higher than CS. It was concluded that the method of dentine preparation and adhesive system tested influenced in bond strength / Orientador: Rebéca Di Nicoló / Coorientador: Alessandra Bühler Borges / Banca: Marcelo José Strazzeri Bönecker / Banca: César Rogério Pucci / Mestre
2

Análise da influência de diferentes tratamentos superficiais de sistemas cerâmicos na resistência de união adesiva /

Vasconcellos, Walison Arthuso. January 2005 (has links)
Resumo: A cimentação é vital para o sucesso clínico de restaurações cerâmicas puras e é dependente de muitos fatores como a composição dos materiais cerâmicos, tratamento de superfície, e agente cimentante. O objetivo deste estudo foi investigar a influência de diferentes tratamentos superficiais (microjateamento, microjateamento + condicionamento com ácido fluorídrico e silicatização) de diferentes materiais cerâmicos (Duceram Plus - Degussa, IPS Empress 2 - Ivoclar Vivadent, In-Ceram Alumina - Vita) na resistência de união adesiva, usando o teste de microtração. Dezoito terceiros molares humanos superiores recém extraídos foram usados. Os dentes foram limpos e mantidos em solução salina com timol a 0.2% em temperatura ambiente. A superfície oclusal foi cortada perpendicular ao longo eixo do dente com disco diamantado em baixa rotação em máquina de corte. Os dentes foram aleatoriamente divididos em três grupos (n=6) da seguinte forma: Grupo I. Duceram Plus - Degussa; Grupo II. IPS Empress 2 - Ivoclar Vivadent; and Grupo III. In-Ceram Alumina - Vita. Moldagens foram feitas em todos os dentes com silicona de adição e obtidos troquéis em gesso tipo IV. Cada grupo foi dividido em três subgrupos (n=2), em função do tratamento superficial (A, B e C). Tratamento A: microjateamento com óxido de alumínio 50 mm. Tratamento B: microjateamento com óxido de alumínio 50 mm, seguido de condicionamento com ácido fluorídrico a 10%. Tratamento C: microjateamento com partículas de alumina com 100 mm (Rocatec pré), seguido por jateamento com partículas de alumina modificada por sílica (Rocatec plus)... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The cementation is vital for the clinical success of all-ceramic restorations and is dependent of many factors as composition of the ceramic materials, surface treatment and luting agent The purpose of the current study was to investigate the influence of different surface treatment (micro etching, micro etching + etching with fluoric acid and tribochemical silica coating process) of different ceramic materials (Duceram Plus - Degussa, IPS Empress 2 - Ivoclar Vivadent, In-Ceram Alumina - Vita) on bond strength at dentin, using the micro-tensile test. Eighteen freshly extracted human maxillary molars were used. The teeth were cleaned and stored in saline solution with timol 0.2% at room temperature. The occlusal surfaces were flattened perpendicular to long axis of the teeth with slow-speed diamond saw sectioning machine. The teeth were randomly divided into three groups (n=6 each) as follows: Group I. Duceram Plus - Degussa; Group II. IPS Empress 2 - Ivoclar Vivadent; and Group III. In-Ceram Alumina - Vita. Impressions were made of all teeth preparations with vinyl polysiloxane impression material and poured in a vacuum-mixed die material. Each of the 3 groups was divided into 3 sub-groups (n=2 each), in function of surface treatment (A, B e C). Treatment A: micro etching with 50 mm alumina particles. Treatment B: micro etching with 50 mm alumina particles + etching with 10% hydrofluoric acid. Treatment C: micro etching with 100 mm alumina particles (Rocatec pre) and 100 mm alumina particles modified with silica (Rocatec plus). All specimens were rinsed under running tap water and a silane solution was applied on ceramics specimens... (Complete abstract, click electronic address below). / Orientador: Alexandre Henrique Susin / Coorientador: José Roberto Cury Saad / Banca: Osmir Batista de Oliveira Júnior / Banca: Maria Salete Machado Cândido / Banca: Edson Alves de Campos / Banca: Rodrigo de Castro Albuquerque / Doutor
3

Resistência de união de cimentos resinosos, ao cisalhamento, variando o substrato e o material restaurador /

Ariki, Eurípedes Kaizo. January 2009 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Eduardo Galera da Silva / Banca: Marco Antonio Meloncini / Resumo: O objetivo deste estudo foi avaliar a resistência de união ao cisalhamento de três diferentes tipos de agentes cimentantes: auto-condicionante (Panavia F / P), convencional (RelyX ARC - R) e auto-adesivo (RelyX U100 - U), usando dois tipos de substratos (esmalte / E e dentina / D) e dois tipos de materiais restauradores (cerâmica - C e resina composta laboratorial - R). Foram utilizados cento e vinte incisivos bovinos incluídos em resina acrílica, de modo que uma parte da face vestibular ficasse exposta. Os dentes foram desgastados até se obter uma área lisa e plana, de aproximadamente de 25 mm2, em metade dos espécimes foi exposto esmalte, na outra metade dentina. Uma fita adesiva com um orifício no centro com 3 mm de diâmetro foi colada sobre estas áreas, delimitando a área a ser usada no teste. Foram confeccionados sessenta cilindros de cerâmica a base de dissilicato de lítio (IPS e.max) e sessenta cilindros de resina composta (SR Adoro) com dimensões de 3mm de diâmetro e 3mm de altura. Os cilindros foram cimentados aos substratos com os três tipos de cimento resinoso, formando doze grupos experimentais: G1(PEC); G2(PER); G3(PDC); G4(PDR); G5(REC), G6(RER); G7(RDC); G8(RDR): G9(UEC); G10(UER); G11(UDC) e G12(UDR). Após um período de uma semana, os corpos-de-prova foram levados à máquina de ensaios universais para a realização do teste de cisalhamento com velocidade de 0,5 mm/min. Os resultados (foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey em nível de 5% de significância. Verificou-se que o maior valor médio obtido foi do G5 (17,46 MPa) diferindo significativamente dos demais grupos, exceto do G1 (14,60 MPa). O G12 (1,03 MPa) apresentou o menor valor de resistência, não apresentando semelhança estatística com os outros grupos. A adesão em esmalte... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study was to evaluate the shear bond strength of three types of luting agents: self-etching (Panavia F, P), conventional (Rely X ARC, R) and self-adhesive (Rely X U100, U), using enamel (E) or dentin (D) as substrates and two types of restorative materials (ceramic, C and laboratorial composite, R). One hundred and twenty-five bovine incisors were embedded in acrylic resin leaving their bucal side exposed. The teeth were ground flat until a 5mm2 area was created. Half of the specimens had enamel exposed and the other half had dentin exposed. A piece of tape with a 3 mm hole was used to delimitate the bonding area. Sixty cylinders of ceramic (IPS E.max Press) and sixty of composite (SR Adoro), 3 mm in diameter and 3 mm in height, were confectioned. The cylinders were luted to the substrates, forming twelve groups: G1 (PEC); G2 (PER); G3 (PDC); G4 (PDR); G5 (REC), G6 (RER); G7 (RDC); G8(RDR): G9 (UEC); G10(UER); G11(UDC) and G12(UDR). After one week, the specimens were subjected to a shear test in a universal testing machine at a crosshead speed of 0,5 mm/min. The results were submitted to both the Anova and Tukey tests (p<0.05) for statistical analysis. It was observed that the mean of G5 (17,46 MPa) was significantly different from the other groups means, except for G1 (14,60 MPa). Statistically G12 (1,03) had the lowest bond strength differing from the other groups. Bondings between was ceramic and enamel determined the highest bond strength for all luting agents. Due to the low bond strength and the failures between cement and substrate, using the self-adhesive cement and laboratorial composite to make bonds is not advisable. / Mestre
4

Avaliação de tratamentos de superfície em diferentes sistemas cerâmicos e seu efeito na resistência de união a um cimento resinoso /

Ribeiro, João Gustavo Rabelo. January 2005 (has links)
Orientador: José Cláudio Martins Segalla / Banca: Regina Helena Barbosa Tavares da Silva / Banca: Marcos Ribeiro Moysés / Resumo: O objetivo deste estudo foi avaliar o efeito de três tratamentos superficiais na resistência de união de um cimento resinoso a três cerâmicas dentais: Duceram Plus (DP), IPS Empress II (IPS) e In-Ceram Alumina (INC), e analisar a topografia superficial dessas cerâmicas submetidas aos mesmos tratamentos superficiais. Para o teste de resistência de união foram confeccionadas 18 amostras de cada material (7,5mm de diâmetro x 3,0mm de espessura), incluídas em resina acrílica e polidas até lixa nº 600. As amostras foram divididas em três grupos: a) jateamento com partículas de óxido de alumínio de 50 æm; b) condicionamento com ácido fluorídrico 10%; c) associação de "a" e "b". As amostras foram lavadas e secas. A área de adesão da cerâmica foi delimitada com matriz metálica perfurada (5,0mm de diâmetro e 3,0mm de espessura). Foi aplicado silano, adesivo e cimento resinoso Variolink II, fotoativado por 40 segundos. As amostras receberam 1000 ciclos térmicos de 5 a 55°C. O ensaio de cisalhamento foi realizado em máquina de ensaios MTS 810, com célula de carga de 10 kN e velocidade de 0,5 mm/min. Para a topografia superficial foram confeccionados um coping de IPS, um do INC e uma coroa de DP, seguindo as recomendações dos fabricantes. Cada coping ou coroa foi cortado com disco diamantado em quatro partes: uma delas não recebeu nenhum tratamento, e as demais receberam um dos tratamentos acima descritos. Fotomicrografias foram obtidas por meio de microscopia eletrônica de varredura e a análise foi feita de acordo com a característica da superfície. Pode-se concluir que: o tratamento associado não ofereceu vantagens em relação ao condicionamento ácido, para os materiais DP e IPS; para o INC o tratamento associado não ofereceu vantagens em relação ao jateamento. A DP e o IPS apresentaram resultados melhores em relação ao INC, independentemente dos tratamentos ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of three surface treatments on the shear bond strength of a resin luting cement to three ceramics materials: Duceram Plus (DP), IPS Empress II (IPS) and In-Ceram Alumina (INC), and to assess its surface topography after these treatments. Eighteen specims were fabricated to each material (7,5 mm in diameter x 3,0 mm in thickness), embebed in acrylic resin and ground up to 600 grit. The specims were randomly divided into 3 groups of 6 specims: (a) airborne particle abrasion with 50 æm aluminum oxide; (b) 10% hydrofluoric acid etching; (c) "a" and "b" treatments. The specims were cleaned and dried. Silane, adhesive and resin luting cement Variolink were applied in 5,0 mm in diameter and 3,0 mm height to ceramic surface and then light cured. All specims were termocycled (1000, 5-55°C). The shear bond strength was then measured in a testing machine MTS 810, at a crosshead speed of 0,5 mm/min. To asses the surface topography, one coping each of IPS and INC, and a DP crown were fabricated following the manufacturer's instructions. Each coping or crown was sectioned into 4 equal parts by a diamond disk. One part didn't receive any treatment, and the others, received treatments as above described. Photomicrographs were obtained by a SEM, and the superficial characteristic was described. In conclusion, the associate treatment didn't offer advantages in relation to the acid etching, for DP and IPS; for INC the associate treatment didn't offer advantages in relation to the airborne. DP and IPS presented the best results, independently of the superficial treatments. The photomicrographs showed compatible correlation of the superficial characteristic with the bond strength values. / Mestre
5

Efeito de desinfecções sucessivas com energia de microondas na resistência de união entre dentes artificiais e resinas para bases de próteses /

Chuqui, Roberta. January 2005 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Ana Lucia Machado / Banca: Hércules Jorge Almilhatti / Resumo: Este estudo avaliou o efeito de desinfecções sucessivas por meio da utilização de microondas sobre a resistência de união entre dentes artificiais (incisivos centrais superiores: Biotone - DB, modelo 264 e Vivodent - DV, modelo A15) e resinas para bases (QC20 - QC, Acron MC - AC e Lucitone 550 - L). Os dentes artificiais foram posicionados em anéis de PVC (20 mm de diâmetro e 20 mm de altura) preenchidos com cera. Cada anel foi incluído em silicone por condensação para facilitar posteriormente a remoção das amostras polimerizadas. Esses moldes de silicone foram então incluídos em mufla dental com gesso. A cera foi eliminada com água em ebulição, sendo o molde preenchido com resina acrílica, manipulada e polimerizada de acordo com as instruções do fabricante. Quarenta corpos-de-prova foram obtidos para as três resinas de base com as duas marcas de dentes avaliados. Todas as amostras foram divididas aleatoriamente em quatro grupos. G1 (controle) - amostras imersas em água destilada a 37ºC por 48 horas; G2 - imersas por 48 horas e submetidas a dois ciclos de desinfecção por 6 minutos a 650 W; G3 - imersas por 48 horas em água destilada e submetidas a sete ciclos de desinfecção (um por dia) por 6 minutos a 650 W, estando as amostras imersas em água a 37ºC entre as desinfecções; G4 - imersas em água destilada por 8 dias (controle). O teste de cisalhamento foi realizado em máquina de ensaios MTS - 810 com a força aplicada na superfície palatina dos dentes em ângulo de 45º e velocidade de 0,5 mm/min. As superfícies de fratura foram observadas em lupa esteroscópica com um aumento de 10 vezes para determinar a natureza da falha (adesiva, coesiva ou mista). Adicionalmente, foi realizada microscopia eletrônica de varredura. Os dados (MPa) foram analisados utilizando ANOVA, teste de Tukey e teste t de Student (P=0,05)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of microwave disinfection on the bond strength of denture teeth (maxillary central incisors: Biotone - DB, model 264 and Vivodent - DV, model A15) to acrylic resins (QC20 - QC, Acron MC - AC and Lucitone 550 - L). Denture teeth were positioned within polyvinylchloride tubes (20 mm diameter and 20 mm length) filled with melted wax. The tubes were invested in silicone rubber to facilitate removal of the processed specimens from the flask. These silicone moulds were then invested in the usual denture flasks in dental stone. The wax was boiled out, the mould was packed with denture resin and polymerized according to the manufacturer's instructions. Forty specimens were formed from each of the three denture base resin with the two brands of denture teeth. All specimens were randomly divided into four groups to provide a sample size of 10. G1 (control group) - immersed in distilled water at 37ºC for 48 hours; G2 - immersed in distilled water at 37ºC for 48 hours and microwaved twice at 650W for 6 minutes; G3 - immersed in distilled water at 37ºC for 48 hours and microwaved (650 W for 6 minutes) daily for 7 days, being stored in water at 37ºC between exposures; G4 (control group) - immersed in distilled water at 37ºC for 8 days. Shear load was applied with a load testing machine at 45 degrees from the long axis of each denture tooth on the palatal surface at a crosshead speed of 0.5mm/min until fracture. Fracture surfaces were evaluated with an optical stereomicroscope under x 10 magnifications to determine the nature of the failure (adhesive, cohesive or combination). In addition, a representative sample of each experimental group was evaluated with a scanning Electron Microscopy (SEM). The data (MPa) were analyzed statistically using 3-way ANOVA, Tukey's test and Student's t test (P=0.05)...(Complete abstract, click electronic address below) / Mestre
6

Análise in vitro da resistência de união da resina composta à dentina tratada com diferentes sistemas adesivos /

Xavier, Cláudia Cristina Galvão. January 2005 (has links)
Orientador: Sizenando de Toledo Porto Neto / Banca: Marcelo Ferrarezi de Andrade / Banca: Maria Salete Machado Cândido / Banca: Alberto Magno Gonçalves / Banca: Edson Alves de Campos / Resumo: Este trabalho teve como objetivo avaliar in vitro a força de união da resina composta à dentina tratada com quatro adesivos dentinários, sendo dois sistemas universais simplificados (G1- Prime & Bond® NT/ Dentsply, G2- Single Bond/ 3M) e dois auto-condicionantes (G3- AdheSE® / Vivadent, G4- Adper- PromptL-Pop/ 3M). Para a realização deste estudo, foram selecionados 20 terceiros molares humanos íntegros e livres de cárie, que tiveram suas superfícies oclusais cortadas em 3mm. Após o corte, cada grupo de dentes receberam seus respectivos sistemas de tratamento adesivo, pré-selecionados. Todas as amostras de dentes foram restauradas com a resina composta Tetric Ceram® / IvoclarVivadent, termocicladas em 550 ciclos e cortadas. Dessa forma, obtendo-se espécimes de 1,0mm2 l0,1mm2 que foram levados a uma Máquina de Teste Universal onde foi realizado o ensaio de microtração. Os tipos de fraturas foram analisados, mediante microscopia óptica (40X) e as fraturas mais representativas foram levadas à microscopia eletrônica de varredura. Os resultados mostraram que os sistemas universais simplificados (G1 e G2) apresentaram valores de resistência de união mais elevados do que os sistemas auto-condicionantes (G3 e G4). A maioria das fraturas encontradas foram do tipo adesiva para os grupos G3 e G4, enquanto nos grupos G1 e G2 87% dos modos de fraturas foram distribuídas entre adesivas e coesivas da resina. / Abstract: This work had with aim to evaluate "in vitro" the bond strength of composite resin to dentine bonded with four dentin adhesives. In this study, were used two one-step adhesive systems (G1- Prime & Bond® NT/Dentsply, G2-Single Bond/ 3M)and two self-etching adhesive systems (G3- AdheSE® /Vivadent, G4- Adper Prompt L-Pop/3M). For this, were chosen twenty human healthy third molars, that had their oclusal surfaces cut in 3mm. After the cut, each group of teeth received their respectives adhesive systems, even then chosen. All the samples were restored with the composite Tetric Ceram® / IvoclarVivadent, thermocycled 550 times and cut. Then, obtaining specimens of 1,0mm2 l 0,1mm2 that were made a test of micro tensile bond strength in a Universal Test Machine. The fractures were analyzed in a optical microscope (40X), and the more representative fractures were then analyzed at scanning electronic microscope. The results revealed that the one-step adhesive systems (G1 and G2) showed higher values of bond strength compared to the self-etching adhesive systems (G3 and G4). The fractures more commum were the adhesive type in the G3 and G4 groups, while in the G1 and G2 groups, 87% of the fractures were the adhesive and cohesion of resin types. / Doutor
7

Influência de sistemas adesivos e da região do dente na durabilidade da união entre dentina e pino de fibra /

Melo, Renata Marques de. January 2009 (has links)
Orientador: Marco Antonio Bottino / Banca: Luiz Felipe Valandro / Banca: Marcelo Giannini / Banca: Marcela Rocha de Oliveira Carrilho / Banca: Maximiliano Piero Neisser / Resumo: Esse estudo avaliou a performance de dois adesivos com condicionamento ácido prévio (All- Bond 2 e One-step Plus - Bisco) e dois sistemas adesivos autocondicionantes (Clearfil SE Bond- Kuraray e Xeno III- Dentsply) quanto à resistência de união à dentina coronária e do canal radicular, penetração do adesivo na dentina desmineralizada e influência sobre o grau de conversão do cimento resinoso. Também foi determinada, com mecânica da fratura, a tenacidade da interface pino/cimento/dentina formada com o adesivo All-Bond 2. O canal radicular de 80 dentes humanos anteriores superiores foi instrumentado e, em seguida, preparado com brocas do sistema de pinos FRC Postec (Ivoclar). A dentina foi tratada com um dos sistemas adesivos e o pino foi cimentado com cimento Duo-link (Bisco). Oito grupos foram formados de acordo com o sistema adesivo e o tempo de armazenagem em saliva artificial (7 d ou 4 m). Seis secções transversais (~1,0 mm) foram obtidas das regiões compreendidas entre 4 mm acima da JEC até 4mm do ápice radicular, isto é, dentina coronária e do canal radicular. Três destas seis secções foram submetidas ao teste de pushout em máquina de ensaio universal Instron (1 mm/min, 50 Kgf). Nas secções restantes foram avaliados o grau de conversão do cimento e a penetração do adesivo na dentina com μ-Espectroscopia Raman. As amostras de tenacidade consistiram de dois hemi-discos de resina reforçada por fibra (pino) cimentados a duas fatias de dentina da câmara pulpar, formando um sanduíche (espécime Brazil nut). Os resultados do teste Anova 3-fatores de medida repetida (p<0.05) indicam que, apenas, a "região" exerceu efeito significante sobre a resistência de união (MPa). Na porção coronária (4,20 MPa) a resistência foi maior que nas regiões média (3,45 MPa) e apical (3,26 MPa) (Tukey, 5%). A tenacidade de fratura da interface cimento-dentina foi maior... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the performance of two etch-and-rinse (All-Bond 2 andOne-step Plus- Bisco) and two self-etch adhesive systems (Clearfil SE Bond- Kuraray and XenoIII-Dentsply) concerning their bonding durability to coronal and root canal dentin, infiltration onto dentin and influence on the degree of cure of a dual-cure cement. It was also determined the interfacial fracture toughness of the post/cement/dentin interface forme with All-Bond 2. The root canals of 80 human incisors and canines were instrumented and prepared with burs (FRC Postec System, Ivoclar). Dentin was treated with one of the four adhesives and FRC Postec posts (Ivoclar) were cemented to the root canal with Duo-link dual-cure resin cement (Bisco). Eight groups were formed according to the adhesive system employed and the aging time in water (7 or 4 m). Six transverse sections (~1.0 mm) were cut from 4 mm above the CEJ up to 4 mm short of the root canal apex, comprising coronal and root canal dentin. Three out of the six sections were submitted to push-out testing in an Instron machine (1 mm/min, 50 Kgf). The degree of conversion of the cement and the infiltration of the adhesive were evaluated in the remaining sections through Raman μ-Spectroscopy. The fracture toughness specimens were made out of two half disks of fiber-reinforced composite (post) cemented to dentin pieces, forming the Brazil nut specimen. The analisys obtained with the 3-way Anova of repeated measures test (p<0.05) showed that only the "region" had statistically significant effects on the bond strengths (MPa). Comparison of the means achieved in each region (Tukey, p < 0.05) revealed that the coronal portion (4.20 MPa) was higher than the cervical (3.45 MPa) and middle portions (3.26 MPa) of the root, which were not statistically different. The interfacial fracture toughness was higher for the cement-dentin interface than... (Complete abstract click electronic access below) / Doutor
8

Resistência adesiva de um sistema auto-condicionante e um convencional simplificado, aplicados à dentina tratada com diferentes condicionadores /

Jacques, Paula. January 2002 (has links)
Orientador: Josimeri Hebling / Banca: Ricardo Marins de Carvalho / Banca: Elisa Maria Aparecida Giro / Resumo: A resistência adesiva de um sistema auto-condicionante e um convencional simplificado, Clearfil SE Bond e Single Bond, respectivamente, quando aplicados à dentina superficial tratada com diferentes agentes condicionadores, foi avaliada por meio de ensaios mecânicos de microtração. Superfícies planas de dentina, obtidas removendo-se a superfície oclusal de 30 terceiros molares humanos foram polidas com lixa de granulação 600 antes da aplicação de diferentes agentes condicionadores, SE Primer, ácido fosfórico ou EDTA. O primer acidificado SE Primer foi aplicado sobre a superfície por 20 segundos, seguido de suave secagem com jatos de ar. O ácido fosfórico a 37% foi aplicado por 15 segundos, seguido de lavagem e remoção do excesso de água com papel absorvente e a solução de EDTA 0,5M pH7,2 foi aplicada por 30 segundos, também seguida de lavagem e secagem. Com exceção das superfícies que receberam a aplicação do primer acidificado, as demais foram mantidas úmidas para a posterior aplicação dos sistemas adesivos avaliados. Sobre a superfície coberta pelo sistema adesivo foi construída uma coroa em resina composta Z250 e os dentes foram mantidos em água a 37% por 24h. Após 500 ciclos térmicos em temperaturas de 5o e 55oC, cortes paralelos no sentido mesio-distal e cortes perpendiculares aos primeiros, no sentido vestibulo-lingual, permitiram a obtenção de amostras com área de secção transversal quadrangular de 1,0mm2 em número mínimo de 10 para cada dente. Cada amostra foi colada a um dispositivo especialmente desenvolvido, e este foi acoplado à uma máquina universal de testes operada à velocidade de 0,5mm/min. O lado correspondente à dentina de aproximadamente 50% das superfícies fraturadas após o ensaio mecânico foi analizado em MEV. Os resultados mostraram que o maior valor médio de resistência adesiva foi observado para a associação SE Primer... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: Microtensile bond strength of a self-etching primer and a conventional one-bottle system, Clearfi SE Bond and Single Bond, respectively, bonded to superficial dentin treated with different conditioners was investigated. Flat dentin surfaces obtained by removing the occlusal enamel with a diamond saw were ground with 600-grit SiCs under wet conditions to create the smear layer before the conditioners application. Three different dentin conditioning was performed, SE Primer, phosphoric acid and EDTA. The SE Primer was applied on dentin for 20 seconds followed by slight air-drying. Phosphoric acid (37%) was applied for 15 seconds followed by rinsing. EDTA 0.5M pH7.2 was applied for 30 seconds, also followed by water rinsing. Except for the surfaces that received the SE Primer conditioner, the surfaces were left moist by blot-drying the excess water. The adhesive systems were applied and a 5mm high composite resin (Z250) was built up covering the whole surface. After 24h of storage in water at 37oC the teeth were thermocycled for 500 cycles at preset temperatures of 5o and 55oC. The teeth were sectioned with a diamond saw, perpendicular to the adhesive interface to produce beams with 1.0mm2 of adhesive area. These specimens were then attached to a testing apparatus and a tensile load was applied by a universal machine at a crosshead speed of 0.5mm/min. After the micro-tensile bond test, the dentin side of 50% of the fractured surfaces was examined under a scanning electron microscope. The highest tensile bond strength mean was found for the association of SE Primer and Single Bond, 58.51MPa, followed by the association Clearfil SE Bond and EDTA, 47.81MPa. The remaining associations showed mean tensile bond strength statistically similar, except for the association Single Bond and EDTA, which showed the lowest... (Complete abstract, click electronic address below). / Mestre
9

Resistência adesiva e citotoxicidade "In vitro" de diferentes gerações de adesivos dentinários /

Silva, João Maurício Ferraz da. January 2010 (has links)
Orientador: José Roberto Rodrigues / Banca: Eduardo Shigueyuki Uemura / Banca: Carlos Henrique Ribeiro Camargo / Banca: George Miguel Spyrides / Banca: Gorgulho Zanet / Resumo: O objetivo do estudo foi avaliar quatro diferentes sistemas adesivos (Multi- Purpose, Single Bond, SE Plus e Easy Bond - 3M ESPE) no que se refere à resistência adesiva ao microcisalhamento na dentina bovina. Além de avaliar a citotoxicidade desses novos sistemas adesivos por meio do teste de barrerira dentinária e ensaio de MTT em fibroblastos pulpares bovinos. Para o teste de microcisalhamento 80 dentes bovinos tiveram suas raízes seccionadas, foram embutidos em resina acrílica e tiveram a superfície vestibular desgastada expondo-se a dentina, sendo que em 40 dentes a espessura de dentina remanescente foi de 500μm e nos outros 40 de 200μm. Os cdp receberam então o procedimento adesivo de acordo com as instruções do fabricante e com auxílio de uma matriz metálica, cilindros de resina (Z 250 - 3M ESPE) de 0,8 mm de diâmetro e 1mm de altura foram construídos. Após 24h os cdp foram então submetidos ao ensaio de microcisalhamento. Para avaliar a citotoxicidade foi usado o teste de barreira dentinária. Células pulpares bovinas transformadas foram cultivadas em redes de nylon por 2 semanas, obtendo-se uma cultura de 3 dimensões. Essas culturas celulares foram separadas dos materiais testados por fatias de dentina de 500 e 200μm em um dispositivo de perfusão celular. Os materiais foram aplicados na porção cavitária do dispositivo de acordo com as instruções do fabricante, e um material de moldagem a base de silicona (President, Coltene) foi usado como controle negativo (100% de viabilidade celular). Após 24 h de periodo de exposição, a viabilidade celular foi mensurada fotometricamente (teste MTT). Por meio de estatística descritiva verificou-se que a melhor eficiência adesiva foi apresentada pelo adesivo auto-condicionante de um passo só, Easy Bond (21,06 MPa - 200μm; 27,01 MPa- 500μm) seguido pelo Single Bond (15,64 MPa - 200μm; 23,45 MPa- 500μm), SE Plus... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate four different adhesive systems (Multi- Purpose, Single Bond, SE Bond Plus and Easy - 3M ESPE) with regard to microshear bond strength to bovine dentin. In addition evaluate the cytotoxicity of these new adhesive systems by means of a dentin barrier test. To test microshear 80 bovine teeth had their roots sectioned and were embedded in acrylic resin. The buccal surface had been worn to expose the dentin, in 40 teeth the remaining dentin thickness was 500μm and 200μm in the other 40. The specimes received the adhesive procedure according to the manufacturer's instructions and with the aid of a metal matrix, cylinders of resin (Z 250 - 3M ESPE) from 0.8 mm in diameter and 1mm in height were built. After 24h the specimes were then subjected to the microshear testing To evaluate the cytotoxicity, a dentin barrier test was used. SV3NeoB transfected bovine pulp derived cells were grown on nylon meshes for 2 weeks achieving a 3-dimensional cell culture as described. These cell cultures were separated from the test materials by dentin slices of 200 or 500μm thickness in a cell cultures perfusion chamber. The materials were applied into the cavity part of the device according to manufacturer's instruction, and a silicon impression material (President, Coltene) served as a negative control material (100% cell viability). After a 24h exposure period, cell viability was measured photometrically (MTT test). Median values (plus 25% and 75% percentiles) of cell viability measurements (n=10) were statistically analyzed (Mann-Whitney test, = 0.05). Descriptive statistics found that the best bonding performance was presented by the single step adhesive Easy Bond (21.06 - 200μm, 27.01 - 500μm) followed by Single Bond (15.64 - 200μm; 23.45 - 500μm), SE Plus (18.23 - 200μm; 20.07 - 500μm) and Multi Purpose (15.24 - 200μm; 17.99 - 500μm). Moreover, it was... (Complete abstract click electronic access below) / Doutor
10

Avaliação "in vitro" da resistência de união em dentina irradiada com o laser de Er:Yag, mediante a aplicação de diferentes sistemas adesivos /

Guzmán Sierpinski, Liz Marie. January 2002 (has links)
Resumo: O objetivo deste trabalho foi avaliar a influência que o laser de Er:YAG exerce sobre a resistência de união do material restaurador ao substrato dentinário, associando-se a diferentes sistemas adesivos. Para isto foram avaliados 30 molares humanos livres de cárie divididos em três grupos experimentais, utilizando o laser de Er:YAG com uma energia de 260 mJ/10Hz e três grupos controles, em que foram aplicados os seguintes tratamentos: G1) laser, ácido fosfórico a 37%, Excite/Vivadent; G2) controle, ácido fosfórico a 37%, Excite/Vivadent; G3) laser, sistema adesivo Prompt L-pop/Espe; G4) controle, Prompt L-pop;/Espe; G5) laser, ácido fosfórico a 37%, Single Bond/3M; G6) controle, ácido fosfórico a 37%, Single Bond/3M. Todas as amostras foram restauradas com a resina composta Tetric Ceram/Vivadent, termocicladas em 550 ciclos e cortadas, obtendo-se espécimes de mais ou menos 1mm,2 para serem levados a uma Máquina de Testes Universal onde foi realizado o ensaio de microtração. Os tipos de fraturas ocorridos foram analisados mediante microscopia óptica digital e as fraturas mais representativas foram levadas à microscopia eletrônica de varredura. Os resultados mostraram que o sistema laser de Er:YAG apresentou as menores médias de tensão de ruptura, independente do sistema adesivo utilizado. O sistema adesivo Prompt l-pop mostrou resistência adesiva estatisticamente menor em relação aos outros sistemas adesivos estudados. Não houve diferença estatística entre os sistemas adesivos Single Bond e Excite. A maior parte das fraturas encontradas para todos os grupos foram do tipo adesiva. / Abstract: The aim of this study is to evaluate the influence of the laser Er:YAG to the junction resístance between the tooth surface and the restorative material , using different adhesives . For this study were used 30 human healthy molars, divided in three experimental groups and three control groups. The experimental groups were exposed to a laser of Er:YAG with 260 mJ/10Hz of energy. The six groups were: G1) laser, phosforic acid at 37%, Excite/ Vivadent. G2) control, phosforic acid at 37 % , Excite/ Vivadent. G3) laser, adhesive system Prompt L-pop/ Espe. G4) control, adhesive system Prompt L-pop/ Espe. G5) laser, phosforic acid 37% , Single Bond/ 3M. G6) control, Single Bond/ 3M. All the teeth were restored with the composite Tetric Ceram/ Vivadent. Then thermocycled 550 times and cut in specimens of 1mm2. In these specimens was made a test of micro tensile bond strength in a Universal Test Machine. The fractures were analyzed in a digital optical microscope, and more representative fractures were then analyzed in a electronic microscope. The results revealed that the groups treated with laser Er:YAG presented less tensile bond strengh, independently to the adhesive system used. The adhesive Promp 1-pop presented less tensile bond strengh compared to the other adhesives evaluated. There no was difference between the groups of Single Bond and Excite. The fractures more commun were the adhesive type. / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Vanderlei Salvador Bagnato / Banca: Osmir Batista de Oliveira Júnior / Banca: Alberto Magno Gonçalves / Mestre

Page generated in 0.0915 seconds