• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo comparativo da resistência adesiva da interface resina/bráquete, sob esforços de cisalhamento, empregando três resinas compostas e três tipos de tratamentos na base do bráquete / Comparative study of the shear bond strenght of the resin/bracket interface, using three different resin composites and three different treatments in the bracket-base

Mondelli, Adriano Lia 28 May 2004 (has links)
Analisando o fato de que até o momento a união bráquete/resina é conseguida mecânica e quimicamente, decidiu-se avaliar: 1) a resistência adesiva da interface resina/bráquete sob esforços de cisalhamento, empregando três marcas comerciais de resina composta, Concise Ortodôntico (polimerização química), Transbond XT (fotopolimerizada) e Filtek TM Z-250 (fotopolimerizada); 2) o efeito, nesta resistência adesiva, do jateamento com oxido de alumínio, aplicado na base do bráquete metálico, associado ou não ao sistema adesivo resinoso dentário; 3) a eficiência da metodologia empregada para avaliação da força de união da interface resina/bráquete. Foi utilizado o bráquete da Abzil-lancer código U1L-281-002X, cuja área de colagem linear é de 12,5 mm2. Os testes de cisalhamento foram realizados em máquina Universal Kratos. De acordo com a metodologia empregada e após a análise e discussão dos resultados obtidos, pôde-se concluir: as resinas compostas Concise Ortodôntico, Transbond XT e FiltekTM Z-250, quando aplicadas nas bases metálicas dos bráquetes Abzil, sem nenhum tratamento prévio (grupos controle), apresentaram valores similares de resistência adesiva sob esforços de cisalhamento; no tratamento que inclui aplicação do adesivo específico + resina composta na base do bráquete, o Concise Ortodôntico e o Transbond XT apresentaram resultados mecanicamente semelhantes, porém superiores, estatisticamente, ao Filtek Z-250, para adesão na interface resina/bráquete; o jateamento com óxido de alumínio na base do bráquete é mais efetivo, estatisticamente, para as resinas compostas Concise Ortodôntico e Transbond XT do que para o sistema restaurador FiltekTM Z-250; o tratamento que inclui jateamento com óxido de alumínio + adesivo específico + resina composta na base do bráquete foi mais efetivo, estatisticamente, para os sistemas Concise Ortodôntico e Transbond XT do que para o sistema restaurador FiltekTM Z-250; de maneira geral, a ocorrência 12.5 % de fraturas coesivas pode ser considerada mínima, indicando que a metodologia empregada pode ser considerada confiável para avaliar especificamente a força de união da interface resina/bráquete. / Analyzing the fact that, todays, the bracket/resin union is mecanic and chemically gotten, we decided to evaluate: 1) shear bond strenght of the resin/bracket interface using three commercial marks of resin composites: Concise Orthodontic (chemical-cured), Transbond XT (light-cured) and Filtek TM Z-250 (light-cured); 2) the effect, in this bond strenght, of the sandblasting with aluminum-oxide in the metallic bracket-base, associated or not to a resin adhesive system; 3) the efficiency of the methodology used for evaluate the bond strenght of the resin/bracket interface. The Abzil bracket code was U1L- 281-002X, whose lineal collage area is 12,5 mm2. In agreement with the methodology used and after analysis and discussion of the obtained results, the conclusions were: Concise Orthodontic, Transbond XT and FiltekTM Z- 250 resin composites, when applied in the Abzil metallic brackets-bases, without any previous treatment (control groups) presented similar shear bond strenght values; the treatment with an specific adhesive + resin composite in the bracket-base, Concise Orthodontic and Transbond XT presented similar results, but statistically superiors to Filtek Z-250 for adhesion in the resin/bracket interface; the sandblasting with aluminum-oxide in the bracketbase is statistically more effective, for the Concise Orthodontic and Transbond XT resins composites, than FiltekTM Z-250; the sandblasting with aluminumoxide + specific adhesive + resin composite in the bracket-base was statistically more effective for the Concise Orthodontic and Transbond XT systems, than the FiltekTM Z-250; in a general way, 12.5% of cohesive fractures can be considered minimal, indicating that the methodology used can be considered reliable to evaluate the specific resin/bracket interface bond strenght.
2

Estudo comparativo da resistência adesiva da interface resina/bráquete, sob esforços de cisalhamento, empregando três resinas compostas e três tipos de tratamentos na base do bráquete / Comparative study of the shear bond strenght of the resin/bracket interface, using three different resin composites and three different treatments in the bracket-base

Adriano Lia Mondelli 28 May 2004 (has links)
Analisando o fato de que até o momento a união bráquete/resina é conseguida mecânica e quimicamente, decidiu-se avaliar: 1) a resistência adesiva da interface resina/bráquete sob esforços de cisalhamento, empregando três marcas comerciais de resina composta, Concise Ortodôntico (polimerização química), Transbond XT (fotopolimerizada) e Filtek TM Z-250 (fotopolimerizada); 2) o efeito, nesta resistência adesiva, do jateamento com oxido de alumínio, aplicado na base do bráquete metálico, associado ou não ao sistema adesivo resinoso dentário; 3) a eficiência da metodologia empregada para avaliação da força de união da interface resina/bráquete. Foi utilizado o bráquete da Abzil-lancer código U1L-281-002X, cuja área de colagem linear é de 12,5 mm2. Os testes de cisalhamento foram realizados em máquina Universal Kratos. De acordo com a metodologia empregada e após a análise e discussão dos resultados obtidos, pôde-se concluir: as resinas compostas Concise Ortodôntico, Transbond XT e FiltekTM Z-250, quando aplicadas nas bases metálicas dos bráquetes Abzil, sem nenhum tratamento prévio (grupos controle), apresentaram valores similares de resistência adesiva sob esforços de cisalhamento; no tratamento que inclui aplicação do adesivo específico + resina composta na base do bráquete, o Concise Ortodôntico e o Transbond XT apresentaram resultados mecanicamente semelhantes, porém superiores, estatisticamente, ao Filtek Z-250, para adesão na interface resina/bráquete; o jateamento com óxido de alumínio na base do bráquete é mais efetivo, estatisticamente, para as resinas compostas Concise Ortodôntico e Transbond XT do que para o sistema restaurador FiltekTM Z-250; o tratamento que inclui jateamento com óxido de alumínio + adesivo específico + resina composta na base do bráquete foi mais efetivo, estatisticamente, para os sistemas Concise Ortodôntico e Transbond XT do que para o sistema restaurador FiltekTM Z-250; de maneira geral, a ocorrência 12.5 % de fraturas coesivas pode ser considerada mínima, indicando que a metodologia empregada pode ser considerada confiável para avaliar especificamente a força de união da interface resina/bráquete. / Analyzing the fact that, todays, the bracket/resin union is mecanic and chemically gotten, we decided to evaluate: 1) shear bond strenght of the resin/bracket interface using three commercial marks of resin composites: Concise Orthodontic (chemical-cured), Transbond XT (light-cured) and Filtek TM Z-250 (light-cured); 2) the effect, in this bond strenght, of the sandblasting with aluminum-oxide in the metallic bracket-base, associated or not to a resin adhesive system; 3) the efficiency of the methodology used for evaluate the bond strenght of the resin/bracket interface. The Abzil bracket code was U1L- 281-002X, whose lineal collage area is 12,5 mm2. In agreement with the methodology used and after analysis and discussion of the obtained results, the conclusions were: Concise Orthodontic, Transbond XT and FiltekTM Z- 250 resin composites, when applied in the Abzil metallic brackets-bases, without any previous treatment (control groups) presented similar shear bond strenght values; the treatment with an specific adhesive + resin composite in the bracket-base, Concise Orthodontic and Transbond XT presented similar results, but statistically superiors to Filtek Z-250 for adhesion in the resin/bracket interface; the sandblasting with aluminum-oxide in the bracketbase is statistically more effective, for the Concise Orthodontic and Transbond XT resins composites, than FiltekTM Z-250; the sandblasting with aluminumoxide + specific adhesive + resin composite in the bracket-base was statistically more effective for the Concise Orthodontic and Transbond XT systems, than the FiltekTM Z-250; in a general way, 12.5% of cohesive fractures can be considered minimal, indicating that the methodology used can be considered reliable to evaluate the specific resin/bracket interface bond strenght.
3

Resistência à remoção de braquetes ortodônticos sob ação de diferentes cargas contínuas

Francischone, Carla Giannini 14 June 2006 (has links)
O objetivo deste trabalho foi: 1 - testar se existe alteração na resistência adesiva de dois cimentos utilizados na colagem de acessórios ortodônticos ao esmalte dental bovino, sendo um de polimerização química (Concise Ortodôntico) e outro fotpolimerizável (Transbond XT), após a aplicação de cargas contínuas, mediante testes de cisalhamento, 2 - observar se há diferença entre as cargas utilizadas e 3 - analisar o tipo de falha que ocorrida no momento do deslocamento dos braquetes para os dois cimentos testados. Foram utilizados para este estudo 80 dentes bovinos, 80 braquetes metálicos (Morelli Ortodontia - Braquete Edgewise/ Rickets para colagem), e pesos com 30g, 70g e 120g. O esmalte bovino foi condicionado com ácido fosfórico a 37% por 1 minuto e depois lavado e seco. A aplicação dos adesivos, manipulação e aplicação dos dois cimentos foram feitas de acordo com as instruções dos fabricantes. Para a padronização da espessura de cimento sob o braquete, foi utilizada uma Agulha Maior de Gilmore, posicionada sobre o braquete, de modo a fazer pressão durante a presa dos cimentos. Após 24 horas, os 80 braquetes colados com Concise e Transbond XT aos dentes foram submetidos às cargas contínuas de 30g, 70g e 120g, além do grupo controle onde os espécimes não receberam carga alguma, sendo 10 corpos de prova para cada teste. Os espécimes ficaram imersos em água filtrada por 28 dias dentro de uma estufa a 37°C. Depois deste período, as amostras foram submetidas a testes de cisalhamento em uma Máquina de Ensaios Universal Kratos, através de um dispositivo com alça metálica acoplado à célula de carga com 500kgf a uma velocidade de 0,5mm/min. Os resultados foram registrados e enviados para análise estatística dos resultados através do teste de Análise de Variância a dois critérios de classificação. Ficou concluído que: 1 - o cimento Concise apresentou maior resistência à remoção que o cimento Transbond XT para todas as cargas utilizadas, 2 - não houve diferença estatisticamente significante entre as três cargas utilizadas para os dois cimentos testados; 3 - com relação ao tipo de falha ocorrida no momento da fratura, conforme ocorreu o aumento da carga, a porcentagem de fratura do esmalte diminuiu para o Concise, ao contrário do cimento Transbond XT , onde a porcentagem de fratura de esmalte se manteve constante com o aumento das cargas. Os dois cimentos testados obtiveram resultados aceitáveis para a utilização clínica. / The aim of this study was: 1) to test differences on bond strength between auto-cured (Concise) and light-cured (Transbond XT) cements after static loading and shear test; 2) to observe whether differences exist among static loads and 3) to analyze failure mode after bracket displacement. Eighty bovine teeth and metallic orthodontic brackets (Morelli Ortodontia Braquete Edgewise/Rickets) were tested after static loads of 30, 70 and 120 grs. Bovine enamel was conditioned with 37% phosphoric acid gel for one minute, rinsed and dried. Adhesives were applied and brackets were bonded according to manufacturer\' s instructions. Cement thickness was standardized with the use of a heavier Gilmore needle. After 24 hours, half of the specimens were submitted to the static loads of 30, 70 and 120grs. Control groups remained unloaded. Then, specimens were immersed in distilled water for 28 days at 37oC. Afterwards, orthodontic brackets were attached to a loop wire and submitted to a shear force (Máquina de Ensaios Kratos Universal Kratos) under a crosshead speed of 0.5mm/min and load cell of 500Kgf. A two-way ANOVA test (?=0.05) was used to detect significant interactions between cements and static loads. It was concluded that: 1) The Concise cement showed more statistically significant bond strength values than the TransbondXT cement for all static loads; 2) No statistically significant differences were observed regarding static loads for all cements tested and 3) Higher static loads provided less enamel fracture in the Concise group after shear test, whereas in the Transbond XT the rate of enamel fracture remained unchanged regardless of previous load applied. The two tested cements provided acceptable results for clinical application.
4

Resistência à remoção de braquetes ortodônticos sob ação de diferentes cargas contínuas

Carla Giannini Francischone 14 June 2006 (has links)
O objetivo deste trabalho foi: 1 - testar se existe alteração na resistência adesiva de dois cimentos utilizados na colagem de acessórios ortodônticos ao esmalte dental bovino, sendo um de polimerização química (Concise Ortodôntico) e outro fotpolimerizável (Transbond XT), após a aplicação de cargas contínuas, mediante testes de cisalhamento, 2 - observar se há diferença entre as cargas utilizadas e 3 - analisar o tipo de falha que ocorrida no momento do deslocamento dos braquetes para os dois cimentos testados. Foram utilizados para este estudo 80 dentes bovinos, 80 braquetes metálicos (Morelli Ortodontia - Braquete Edgewise/ Rickets para colagem), e pesos com 30g, 70g e 120g. O esmalte bovino foi condicionado com ácido fosfórico a 37% por 1 minuto e depois lavado e seco. A aplicação dos adesivos, manipulação e aplicação dos dois cimentos foram feitas de acordo com as instruções dos fabricantes. Para a padronização da espessura de cimento sob o braquete, foi utilizada uma Agulha Maior de Gilmore, posicionada sobre o braquete, de modo a fazer pressão durante a presa dos cimentos. Após 24 horas, os 80 braquetes colados com Concise e Transbond XT aos dentes foram submetidos às cargas contínuas de 30g, 70g e 120g, além do grupo controle onde os espécimes não receberam carga alguma, sendo 10 corpos de prova para cada teste. Os espécimes ficaram imersos em água filtrada por 28 dias dentro de uma estufa a 37°C. Depois deste período, as amostras foram submetidas a testes de cisalhamento em uma Máquina de Ensaios Universal Kratos, através de um dispositivo com alça metálica acoplado à célula de carga com 500kgf a uma velocidade de 0,5mm/min. Os resultados foram registrados e enviados para análise estatística dos resultados através do teste de Análise de Variância a dois critérios de classificação. Ficou concluído que: 1 - o cimento Concise apresentou maior resistência à remoção que o cimento Transbond XT para todas as cargas utilizadas, 2 - não houve diferença estatisticamente significante entre as três cargas utilizadas para os dois cimentos testados; 3 - com relação ao tipo de falha ocorrida no momento da fratura, conforme ocorreu o aumento da carga, a porcentagem de fratura do esmalte diminuiu para o Concise, ao contrário do cimento Transbond XT , onde a porcentagem de fratura de esmalte se manteve constante com o aumento das cargas. Os dois cimentos testados obtiveram resultados aceitáveis para a utilização clínica. / The aim of this study was: 1) to test differences on bond strength between auto-cured (Concise) and light-cured (Transbond XT) cements after static loading and shear test; 2) to observe whether differences exist among static loads and 3) to analyze failure mode after bracket displacement. Eighty bovine teeth and metallic orthodontic brackets (Morelli Ortodontia Braquete Edgewise/Rickets) were tested after static loads of 30, 70 and 120 grs. Bovine enamel was conditioned with 37% phosphoric acid gel for one minute, rinsed and dried. Adhesives were applied and brackets were bonded according to manufacturer\' s instructions. Cement thickness was standardized with the use of a heavier Gilmore needle. After 24 hours, half of the specimens were submitted to the static loads of 30, 70 and 120grs. Control groups remained unloaded. Then, specimens were immersed in distilled water for 28 days at 37oC. Afterwards, orthodontic brackets were attached to a loop wire and submitted to a shear force (Máquina de Ensaios Kratos Universal Kratos) under a crosshead speed of 0.5mm/min and load cell of 500Kgf. A two-way ANOVA test (?=0.05) was used to detect significant interactions between cements and static loads. It was concluded that: 1) The Concise cement showed more statistically significant bond strength values than the TransbondXT cement for all static loads; 2) No statistically significant differences were observed regarding static loads for all cements tested and 3) Higher static loads provided less enamel fracture in the Concise group after shear test, whereas in the Transbond XT the rate of enamel fracture remained unchanged regardless of previous load applied. The two tested cements provided acceptable results for clinical application.
5

Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido / The effectiveness of aluminum oxide sandblasting and aluminum oxide discs on shear bond strenght of metal brackets bonded in eroded enamel

Leão, Luciana de Vasconcelos 08 February 2017 (has links)
Dental erosion is a result of the demineralization of enamel surface by the action of acids that soften it, and it may affect bracket adhesion to enamel. This research aimed to assess the effect of the application of aluminum oxide sandblasting and aluminum oxide discs on bond strength of metal brackets rebonded on artificially eroded enamel. Fifty-four crowns of bovine incisors were divided into group functions: Control (artificial saliva), Ox Al (aluminum oxide sandblasting), and SL (aluminum oxide discs Sof-Lex Pop On, 3M ESPE). The crowns were fixed in PVC tubes and enamel surface was flattened with carborundum discs (#320, 600, and 1200 Al2O3 discs; Buehler, Lake Bluff, IL, USA) in metallographic polisher (APL4, Arotec). Knoop microhardness was assessed for the standardization of enamel surfaces (HMV-2000; Shimadzu Corporation, Tokyo, Japan). Next, Ox Al and SL teeth were subjected to the erosive action, submerged in Coca-Cola™ for 1 minute, 3x a day for 7 days. Kirium metal brackets, specific for upper right central incisors, slot 022, Roth prescription (3M/Abzil, São José do Rio Preto, São Paulo, Brazil) were bonded on the buccal aspect of teeth. Shear strength was measured with a universal testing machine EMIC (DL200, EMIC, São José dos Pinhais, Paraná, Brazil) at speed of 0.5 mm/min. The Adhesive Remnant Index (ARI) was performed in samples after shear through a magnifying glass (10x). Kolmogorov-Smirnov, Levene, and homoscedasticity tests were used, as well as ANOVA, for the assessment of microhardness and shear strength. The three groups presented no significant differences for microhardness and shear, but the control group had the highest microhardness mean. There were no statistically significant differences among the three groups for shear bond strength (p=0.163). However, the Ox Al group showed higher values for bond strength. The assessment of ARI of groups showed statistically significant difference when comparing the Control group with Ox Al and SL groups. The ARI values showed the prevalence of ARI 3 (50%) for the control group, followed by ARI 4 (22%) and 5 (22%). For Ox Al and SL, ARI 1 and 2 prevailed. The use of aluminum oxide sandblasting and aluminum oxide discs did not increase bond strength of brackets when they were bonded on artificially eroded enamel. The Adhesive Remnant Index indicated that eroded teeth present higher resin adhesion to enamel. / O objetivo desta pesquisa foi avaliar o efeito da aplicação do microjateamento de óxido de alumínio e de discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte erodido artificialmente. Cinquenta e quatro coroas de incisivos bovinos foram divididas em função dos grupos: Controle (Saliva Artificial), Ox Al (Microjateamento com óxido de alumínio) e SL (discos de óxido de alumínio (Sof-Lex Pop On, 3M ESPE). As coroas foram fixadas em tubos de PVC e a superfície do esmalte foi planificada com discos de carborundum (numerações 320, 600 e 1200 discos de Al2O3; Buehler, Lake Bluff, IL, USA), em Politriz Metalográfica (APL4, Arotec). A microdureza Knoop foi aferida para padronização das superfícies de esmalte (HMV-2000; Shimadzu Corporation, Tokyo, Japan). Após aferição os dentes de OxAl e SL foram submetidos ao desafio erosivo, submersos em Coca-Cola® por 1 minuto, 3X ao dia, por 7 dias. Foram colados braquetes metálicos Kirium específicos para incisivos centrais superiores direitos, slot 022”, prescrição Roth [(3M/Abzil, São José do Rio Preto, São Paulo, Brasil)] na face vestibular do dente. A força de cisalhamento foi mensurada por meio de uma máquina de teste universal EMIC (DL200, EMIC, São José dos Pinhais, Paraná) com velocidade 0,5mm/min. O Índice de Remanescente Adesivo (IRA) foi obtido nas amostras utilizando-se lupa (10X). Foram aplicados os testes de Kolmogorv-Smirnov, de Levene e a homocedasticidade e ANOVA para avaliação da microdureza e força de cisalhamento. Não houve diferenças estatisticamente significantes entre os três grupos quando avaliadas microdureza (p=0,163). Porém, ao avaliar o IRA entre grupos, houve diferença estatisticamente significativa ao comparar o grupo Controle com o OxAl e SL. Sendo a prevalência de IRA 3 (50%) para o grupo controle, seguido de IRA 4 (22%) e 5 (22%), respectivamente. Para OxAl e SL, IRA 1 e 2 prevaleceram. Concluiu-se que o uso de microjateamento de óxido de alumínio e discos de óxido de alumínio não aumentaram positivamente a resistência adesiva dos braquetes quando colados em esmalte erodido artificialmente. O índice de remanescente adesivo indicou que dentes erodidos apresentam uma maior adesão da resina ao esmalte.

Page generated in 0.0395 seconds