Spelling suggestions: "subject:"soleil"" "subject:"dioleil""
1 |
A eficiência do brise-soleil em edifícios públicos de escritórios : estudo de casos no Plano Piloto de BrasíliaSilva, Joene Saibrosa da January 2007 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, 2007. / Submitted by Thaíza da Silva Santos (thaiza28@hotmail.com) on 2009-12-15T21:44:27Z
No. of bitstreams: 1
Dissert_JOENE SAIBROSA DA SILVA.pdf: 23819591 bytes, checksum: 427334d737d178bc8636eafd3a763b7e (MD5) / Approved for entry into archive by Joanita Pereira(joanita) on 2010-01-06T17:06:10Z (GMT) No. of bitstreams: 1
Dissert_JOENE SAIBROSA DA SILVA.pdf: 23819591 bytes, checksum: 427334d737d178bc8636eafd3a763b7e (MD5) / Made available in DSpace on 2010-01-06T17:06:10Z (GMT). No. of bitstreams: 1
Dissert_JOENE SAIBROSA DA SILVA.pdf: 23819591 bytes, checksum: 427334d737d178bc8636eafd3a763b7e (MD5)
Previous issue date: 2007 / O conforto térmico é um dos responsáveis pela qualidade ambiental das edificações e bem estar dos usuários em áreas de trabalho, podendo ser alcançado através da adoção de sistemas passivos de controle ambiental, como por exemplo, a aplicação do brise-soleil. Esse aparato, quando bem especificado, controla ganhos térmicos, melhora a distribuição da iluminação, permite ventilação e pode diminuir o consumo energético, entre outras vantagens. Considerando esses benefícios, este trabalho analisa qualitativamente a eficiência dos brises em edifícios de escritórios públicos do Plano Piloto de Brasília. A cidade, por concentrar a administração do país, apresenta um grande número desses edifícios e, conseqüentemente, de funcionários que podem ter sua qualidade de trabalho comprometida. Para tal, fez-se inicialmente um levantamento de 138 edifícios públicos de escritórios, por meio de observação, para caracterizar as fachadas e verificar a freqüência de utilização de elementos de proteção solar, assim como as tipologias de brises (vertical, horizontal e misto) aplicadas. Em seguida, realizou-se uma análise do tipo de brise mais freqüente por orientação solar em edifícios específicos selecionados, baseando-se em critérios obtidos a partir da bibliografia existente e da carta solar como instrumento de avaliação da eficiência dos mesmos. Entre os resultados, verificou-se que o número de fachadas envidraçadas efetivamente protegidas é relativamente pequeno e que os diversos tipos de brises são utilizados independentemente da orientação. No que diz respeito ao estudo de casos, entre outras conclusões, observou-se em alguns a ausência de controle suficiente da radiação solar, devido às especificações e dimensionamento inadequados, além de problemas como o uso incorreto por parte dos usuários e falta de manutenção. A partir disso, sugerem-se subsídios para diretrizes para a adequação dos brises analisados e para projetos futuros, considerando as orientações predominantes constatadas no levantamento de campo. _______________________________________________________________________________ ABSTRACT / Thermal comfort is one of the main factors that contributes for the indoor environment quality and for the users welfare in work places, and can be attained by the adoption of passive control system, such as use of brise-soleil. This device, when correctly specified, controls thermal gains, improves the light distribution, allows ventilation and can decrease the energy consumption, among others advantages. Considering these benefits, this work analyzes qualitatively the efficiency of brises in public offices buildings of Brasília Pilot Plan. Concentrating the country administration, the city presents a great number of these buildings and, as a consequence, a great number of employees who may have a poor work environment quality . To do so, first a survey of 138 public office buildings was made, by means of observations, to characterize the façades and to verify the frequency of use of solar protection elements, as well as the types of brises (vertical, horizontal and mixed) applied. Then, the most frequently found types of brises for each solar orientation were analyzed in selected buildings, based on criteria obtained in the litterature and in using solar charts as instrument of evaluation of the efficiency. Among the results, it was verified that the number of glass façades effectively protected is small and that the various types of brises are applied regardless of the orientation. Concerning the case studies, among others conclusions, it was observed insufficient solar radiation control in some of them, due to inadequate specifications and sizing, besides other problems, such as incorrect use and lack of maintenance. Finally, subsidies for a guideline for improving the analyzed brises and for future projects are suggested, considering the predominant solar orientations found in the field survey.
|
2 |
Desenvolvimento de produto: pesquisa para proposição de brise-soleil fotovoltaico / Product development: research for project brise-soleil photovoltaicPereira, Amanda Schelgshorn 07 July 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-01-26T18:26:31Z
No. of bitstreams: 1
amandaschelgshornpereira.pdf: 8164581 bytes, checksum: bff8551485b4df0fe3e5788333e7a8b4 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-01-27T11:07:30Z (GMT) No. of bitstreams: 1
amandaschelgshornpereira.pdf: 8164581 bytes, checksum: bff8551485b4df0fe3e5788333e7a8b4 (MD5) / Made available in DSpace on 2016-01-27T11:07:30Z (GMT). No. of bitstreams: 1
amandaschelgshornpereira.pdf: 8164581 bytes, checksum: bff8551485b4df0fe3e5788333e7a8b4 (MD5)
Previous issue date: 2014-07-07 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Devido à redução dos custos de produção no mercado internacional e pelo incentivo ao uso racional dos recursos energéticos, as tecnologias fotovoltaicas apresentam inúmeras possibilidades e boas oportunidades de inovação. Neste sentido, este trabalho é baseado em pesquisa experimental, tendo por objetivo o projeto de um brise-soleil com a utilização de placas fotovoltaicas. Nesta proposição, busca-se aumentar a eficiência energética do módulo fotovoltaico ao se inserir aletas para dissipação de calor. Isto favorece ao resfriamento da superfície posterior do módulo melhorando seu desempenho energético. Para isto, foi realizada revisão detalhada da literatura; identificação das tecnologias utilizadas atualmente; e utilização de software específico para projeto de produto: prototipagem virtual. O processo de projeto foi orientado por metodologia específica da área de desenvolvimento de produtos. Os conceitos elaborados foram validados e ranqueados através do matriz de decisão e por meio de simulação virtual em modelador tridimensional com capacidade de análise de protótipos virtuais. O componente para dissipação de calor foi experimentado em laboratório com auxílio de câmera termográfica, para o registro de variações de temperatura. O brise-soleil fotovoltaico foi projetado em conformidade com o módulo fotovoltaico de modelo SX 120 U da empresa BP Solar. Posteriormente, o projeto foi aplicado em estudo no prédio da Justiça Federal no município de Juiz de Fora (MG). Este estudo foi norteado pelo método prescritivo RTQ-C (2010) – (Requisitos Técnicos da Qualidade para Nível de Eficiência Energética de Edifícios Comerciais, de Serviço e Públicos), onde foi realizada a avaliação da eficiência energética da edificação em sua situação atual, e na situação hipotética, após a experimentação virtual do brise-soleil fotovoltaico na fachada norte. Por fim, destaca-se a colaboração do trabalho para a proposição de soluções que combinam conforto ambiental e eficiência energética em edificações. / Due to the reduction of production costs in the international market and the rational use of energy resources, photovoltaic technologies present many possibilities and good opportunities for innovation. In this sense, this work is based on experimental research, aiming to design a brise-soleil with the use of photovoltaics. In this proposal, we seek to increase the energy efficiency of PV modules by inserting fins for heat dissipation. This favors the cooling of the rear surface of the module improving their energy performance. For this, detailed literature review was conducted; and use of specific software to product design; and virtual prototyping. The design process was driven by a specific methodology in the area of product development. Developed concepts were validated and unranked through the specific decision matrix and through three-dimensional virtual simulation modeler. The component for heat dissipation was tested in the laboratory with the aid of thermographic camera to record temperature changes. Importantly, the brise-soleil PV was designed in accordance with the PV module SX 120 U model company BP Solar. Subsequently, the project was applied to study at the Federal Court building in the city of Juiz de Fora (MG). This study was guided by prescriptive RTQ - C (2010) method, where the rating of the energy efficiency of the building in its current state was performed, and in the hypothetical situation, after the virtual trial brise-soleil PV on the north facade. Finally, there is the collaborative work in proposing solutions that combine environmental comfort and energy efficiency in buildings.
|
3 |
Análise de simulação de uso do Brise-Soleil como sistema de controle termal de uma fachadaGomes, Diego de Miranda Mariath January 2018 (has links)
Submitted by Gisely Teixeira (gisely.teixeira@uniceub.br) on 2018-06-16T14:19:49Z
No. of bitstreams: 1
51500353.pdf: 825277 bytes, checksum: c0a56c36defe2ac1db2657328abc32ff (MD5) / Made available in DSpace on 2018-06-16T14:19:49Z (GMT). No. of bitstreams: 1
51500353.pdf: 825277 bytes, checksum: c0a56c36defe2ac1db2657328abc32ff (MD5)
Previous issue date: 2018 / O artigo simula a instalação de brise-soleil como sistema de controle termal de uma fachada em uma residência em Brasília, Distrito Federal. Levando-se em conta as características do cômodo e sua fachada oeste, foi escolhido o modelo de brise metálico retrátil. Os dados necessários para análise foram obtidos através do aplicativo para smartphone iCelsius e do equipamento portátil FLIR ONE. Os dados obtidos foram analisados apoiando-se em descrições técnicas obtidas pelo fabricante e a partir da bibliografia existente. Os resultados da simulação foram satisfatórios, uma vez que a utilização de brise-soleil como protetor solar diminui a temperatura do ambiente promovendo conforto térmico. Conclui-se que apesar do retorno financeiro pela substituição de aparelhos refrigeradores de ar por brise-soleil, não há garantia de satisfação total e descarte do uso desses aparelhos, uma vez que o conforto térmico é relativo para cada indivíduo, que pode desejar temperaturas ainda mais amenas.
|
4 |
Análise de simulação de uso do Brise-Soleil como sistema de controle termal de uma fachadaGomes, Diego de Miranda Mariath January 2018 (has links)
Submitted by Gisely Teixeira (gisely.teixeira@uniceub.br) on 2018-06-16T14:19:49Z
No. of bitstreams: 1
51500353.pdf: 825277 bytes, checksum: c0a56c36defe2ac1db2657328abc32ff (MD5) / Made available in DSpace on 2018-06-16T14:19:49Z (GMT). No. of bitstreams: 1
51500353.pdf: 825277 bytes, checksum: c0a56c36defe2ac1db2657328abc32ff (MD5)
Previous issue date: 2018 / O artigo simula a instalação de brise-soleil como sistema de controle termal de uma fachada em uma residência em Brasília, Distrito Federal. Levando-se em conta as características do cômodo e sua fachada oeste, foi escolhido o modelo de brise metálico retrátil. Os dados necessários para análise foram obtidos através do aplicativo para smartphone iCelsius e do equipamento portátil FLIR ONE. Os dados obtidos foram analisados apoiando-se em descrições técnicas obtidas pelo fabricante e a partir da bibliografia existente. Os resultados da simulação foram satisfatórios, uma vez que a utilização de brise-soleil como protetor solar diminui a temperatura do ambiente promovendo conforto térmico. Conclui-se que apesar do retorno financeiro pela substituição de aparelhos refrigeradores de ar por brise-soleil, não há garantia de satisfação total e descarte do uso desses aparelhos, uma vez que o conforto térmico é relativo para cada indivíduo, que pode desejar temperaturas ainda mais amenas.
|
5 |
Light, Shadow and Wind in Building DesignKatyarmal, Preeti P. 21 February 2009 (has links)
Design is about understanding a space.
It is about integration of light and air in building design.
It is about light, shadow, reflection.
It is about wind, its movement and escape.
Through designing this project I was able to explore how sun, wind and light can be used effectively in a building design, in my project, in an office environment.
The fire, the Light; the energy is the inspiration behind the origin of Architecture. Energy brings architecture into the world of processes and life and Architecture brings together Fire and Shelter, Chaos and Organization. Day lighting or the use of natural light in a building is one of the fundamental elements used to bring an essential experience of visual comfort and outside world environmental stimulation for all building occupants.
The History of Architecture, said Le Corbusier, is a history of the struggle for light, the struggle for the window.
This thesis assembles the research, conceptualization and final development of the office building design with an integration of light and wind. / Master of Architecture
|
6 |
APPROCHE INVERSE POUR LA RESOLUTION DES CONTRAINTES SOLAIRES ET VISUELLES DANS LE PROJET ARCHITECTURAL ET URBAIN, DEVELOPPEMENT ET APPLICATION DU LOGICIEL SVRHOUPERT, Sylvain 06 November 2003 (has links) (PDF)
Dans cette recherche, nous tentons d'évaluer la pertinence d'une approche de simulation inverse des facteurs physiques d'ambiances dans le processus de conception en architecture et en aménagement urbain. Dans cette perspective, un outil de simulation inverse est développé et interfacé en sur-couche du logiciel de CAO AutoCAD largement utilisé dans les agences d'architectures. Il agrége les méthodes développées au Cerma ces dernières années sur la simulation inverse, de l'ensoleillement d'une part, et de la visibilité d'autre part. Dans le projet architectural ou urbain, la simulation directe solaire ou visuelle permet l'analyse d'une situation à un instant donné ou pour un point de vue donné a posteriori (après la conception d'un projet), tandis que notre démarche inverse consiste à cadrer la génération de solutions architecturales à partir des intentions d'ambiances du concepteur, et ce pour des périodes solaires et des zones de contraintes définies au début d'un projet. Les modélisations inverses de volumes de contraintes solaires et visuelles – ensembles de solutions à une contrainte donnée – ou d'uniques solutions d'ouvertures ou d'écrans sont des réponses optimales aux problèmes spatio-temporels de l'ensoleillement et de la visibilité. Ces volumes englobent l'ensemble des rayons solaires ou visuels joignant une base de contrainte (une zone à ensoleiller ou à protéger du soleil, ou un ensemble de positions potentielles d'un observateur) à une cible de contrainte (période solaire sur la "voûte solaire" ou cible visuelle du type monument, repère...). Ces volumes de contraintes sont aisément manipulables dans le modeleur géométrique. Comme les autres entités qui composent une scène numérique, il est possible de leur faire subir des opérations booléennes, des sections, des translations... Dans un premier temps, nous présentons un état de l'art de cette recherche sur les différents outils et méthodes de simulation inverse 2D puis 3D de l'ensoleillement et de la visibilité. Dans un second temps, nous développons et présentons l'outil SVR ainsi que ses applications. Enfin, nous livrons un état de l'art de quelques observations et méthodes d'observation des concepteurs à l'œuvre et nous évaluons notre logiciel par l'observation des raisonnements et comportements de onze architectes et étudiants en architecture concevant avec notre outil durant des phases d'esquisses et d'avant-projet. Pour cette évaluation, nous mettons en œuvre un protocole d'observation simultané ("think aloud protocol").
|
Page generated in 0.0424 seconds