• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 564
  • Tagged with
  • 564
  • 564
  • 564
  • 564
  • 158
  • 158
  • 134
  • 130
  • 121
  • 114
  • 100
  • 98
  • 89
  • 87
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Áreas de solo exposto intensificam o processo de eutrofização no semiárido brasileiro / Exposed soil areas intensify the eutrophization process in the brazilian semiarid

Morais Neto, João Vieira de 16 March 2018 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-05-02T23:26:11Z No. of bitstreams: 1 JoaoVieiraDeMoraisNeto_DISSERT.pdf: 1165479 bytes, checksum: 412ff7f46c2ad81faf783aa60209e190 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-05-07T23:19:31Z (GMT) No. of bitstreams: 1 JoaoVieiraDeMoraisNeto_DISSERT.pdf: 1165479 bytes, checksum: 412ff7f46c2ad81faf783aa60209e190 (MD5) / Made available in DSpace on 2018-05-07T23:19:31Z (GMT). No. of bitstreams: 1 JoaoVieiraDeMoraisNeto_DISSERT.pdf: 1165479 bytes, checksum: 412ff7f46c2ad81faf783aa60209e190 (MD5) Previous issue date: 2018-03-16 / A substituição da vegetação nativa por atividades antrópicas em uma bacia hidrográfica, geralmente resulta no aumento do carreamento de nutrientes aos ecossistemas aquáticos, reduzindo a qualidade da água destes ambientes. A região semiárida do Nordeste brasileiro atende a esta regra e por possuir solos jovens, é ainda mais susceptível a erosão, o que pode agravar o problema. Identificar as variáveis que podem comprometer a qualidade da água de mananciais é de suma importância para a gestão das bacias, visando gerar políticas públicas de proteção aos mananciais hídricos. Este trabalho tem como objetivo avaliar o poder preditivo das variáveis ambientais de uso e ocupação do solo sobre as variáveis limnológicas de trinta e três reservatórios inseridos nas bacias dos rios Piranhas-Açu e Apodi-Mossoró no semiárido brasileiro (Rio Grande do Norte – RN). A delimitação das sub-bacias, bem como as análises de uso e ocupação do solo foram realizadas através de ferramentas de geoprocessamento como Taudem e o plugin SCP aplicados no software Quantum Gis, separando as classes em: vegetação densa, vegetação esparsa, solo exposto, urbano, agricultura e água. Os dados de qualidade da água foram obtidos junto a um programa estadual de monitoramento de águas superficiais e as variáveis selecionadas foram: fósforo total, nitrogênio total, Demanda Bioquímica de Oxigênio e clorofila-a. Foram realizadas análises estatísticas de correlação de Pearson e Análise de Componentes Principais (PCA) entre os dados limnológicos e do uso do solo para o ano de 2009. Foram encontradas altas correlações positivas significativas (p<0,01) entre as áreas de solo exposto com as variáveis limnológicas nitrogênio total e fósforo total. A PCA confeccionada mostrou que a relação entre o uso do solo e a qualidade da água do reservatório é mais pronunciada na bacia Apodi-Mossoró. Portanto, esses resultados evidenciam que a redução da porcentagem da vegetação nativa e o aumento das áreas de solo exposto tendem a piorar a qualidade da água pela intensificação do processo de eutrofização podendo ocasionar florações de cianobactérias, além do que segundo outros estudos nesta região aponta que estas áreas estão associadas as atividades agrícolas e de pecuária extensiva, e os tipos de solo presentes nas bacias também são variáveis fundamentais no entendimento do processo de enriquecimento dos corpos hídricos. / The replacement of native vegetation by anthropic activities in a watershed usually results in the transport of nutrients to aquatic ecosystems, reducing the water quality of these environments. The semi-arid region of the Brazilian Northeast meets this rule and, because it has young soils, is even more susceptible to erosion, which can exacerbate the problem. Identifying the variables that can compromise the water quality of springs is of utmost importance for the management of the basins, aiming to generate public policies of protection to the water sources. The objective of this study was to evaluate the predictive power of the environmental variables of soil use and occupation on the limnological variables of thirty-three reservoirs inserted in the Piranhas-Açu and Apodi-Mossoró river basins in the Brazilian semi-arid region (Rio Grande do Norte - RN). The delimitation of the sub-basin, as well as the analyzes of land use and occupation were carried out using geoprocessing tools such as Taudem and the SCP plugin applied in the Quantum Gis software, classifying uses in: dense vegetation, sparse vegetation, exposed soil, urban, agriculture and water. The water quality data were obtained from a state program for monitoring surface water and the selected variables were: total phosphorus, total nitrogen, Biochemical Oxygen Demand and chlorophyll a. Statistical analyzes of Pearson correlation and Principal Component Analysis (PCA) were performed between limnological and soil use data for the year 2009. Significant positive correlations (p <0.01) were found between the exposed soil areas with limnological variables total nitrogen and total phosphorus. The PCA made showed that the relationship between the use of the soil and the water quality of the reservoir is more pronounced in the Apodi-Mossoró basin. Therefore, these results show that the reduction of the native vegetation percentage and the increase of the exposed soil areas tend to worsen the water quality by intensifying the eutrophication process, which may lead to cyanobacteria blooms, and according to other studies in this region, these areas are associated with agricultural and extensive livestock activities, and the soil types present in the basins are also fundamental variables in the understanding of the process of enrichment of the water bodies.
72

Virulência e resistência antimicrobiana de Enterococcus sp. isolados de amostras de água / Virulence and antimicrobial resistance of Enterococcus sp. isolated from water samples

Roberto, Sharise Beatriz 17 December 2015 (has links)
Capes / Enterococcus sp. são bactérias caracterizadas como cocos Gram-positivos, frequentemente encontradas na microbiota normal do trato gastrointestinal de humanos e animais, além de serem encontradas em plantas, solo e na superfície da água. Embora sejam considerados microrganismos comensais, Enterococcus sp. podem estar relacionados a uma grande variedade de infecções humanas, e com o rápido crescimento de cidades, muitas vezes sem saneamento básico, a água de superfície serve como disseminação de doenças de veiculação hídrica. Este trabalho apresenta como objetivo, o isolamento e identificação de espécies de Enterococcus de água de superfície da nascente do córrego Jaboti e sua foz, ribeirão Biguaçu e represa do Barreiro, na cidade de Apucarana – PR, além da determinação da sensibilidade desta bactéria a antimicrobianos e fatores de virulência. Os enterococos isolados foram testados quanto à sua resistência a 12 antibióticos através do método de disco difusão, além de análises genotípicas de fatores de virulência e de resistência a antimicrobianos, utilizando a reação em cadeia da polimerase (PCR). Foram confirmados quarenta (40) isolados para o gênero Enterococcus, sendo que as espécies identificadas foram E. italicus (n= 8); E. casseliflavus e E. flavescens (n= 4); E. gallinarum (n= 4); E. seriolicida (n= 3) e E. faecium (n= 2). As taxas de resistência dos isolados foram observadas em 57,5%; 55,0%; 50,0%; 47,5% e 35,0% para eritromicina, penicilina, teicoplanina, vancomicina e ampicilina respectivamente. Genes de resistência encontrados nos isolados foram vanA (37,5%), erm(B) (25,0%), aac (6’)-le-aph(2’’)-la (22,0%); tet(L) (20.0%) e tet(M) (2,5%). Nenhum dos isolados pesquisados apresentaram o gene vanB. Determinantes de virulência dos isolados foram detectados a uma taxa de 17,5 e 2,5% para asa1 e cylA. Não foram identificados os genes gelE, ace agg e cpd nos isolados analisados. A presença de Enterococcus sp. na água representa um problema de saúde pública, uma vez que esta pode servir como disseminação desta bactéria para seres humanos. / Enterococcus sp. are Gram-positive cocci bacteria often found in the normal microflora of the gastrointestinal tract of humans and animals; and also in plants, soil and surface water. Although these microorganisms are considered commensals, Enterococcus sp. can be related to a wide variety of human infections. With the rapid growth of cities, often without basic sanitation, surface water serves as the spread of waterborne diseases through the Enterococcus sp. This work presents as objective the isolation and identification of species of Enterococcus of surface water samples collected from three lakes: Jaboti, Lake Biguaçu and Lake Barreiro, all in the Apucarana City – PR. The virulence factors and sensitivity to antibiotics are were also determined. The isolates were tested for their resistance to 12 antibiotics by disk diffusion method; and the genotypic analysis of virulence factors and antimicrobial resistance genes was carried out using the Polymerase Chain Reaction (PCR). Forty (40) isolates for the genus Enterococcus were confirmed and species were identified as follows: E. italicus (n= 8); E. casseliflavus/E.flavescens (n= 4); E. gallinarum (n=4); E. seriolicida (n= 3) and E. faecium (n= 2). The resistance rates of the isolates were observed of 57,5%; 55,0%; 50,0%; 47,5% and 35,0% for erythromycin, penicillin, teicoplanin, vancomycin and ampicilin respectively. Genes found among isolates were vanA (37,5%); erm(B) (25,0%); aac (6 ') - aph-le (2') – la (22,5%); tet(L) (20,0%) and tet(M) (2,5%). None of the studied isolates presented vanB gene. Virulence determinants of the isolates were detected at a rate of 17,5 and 2,5% for asa1 and cylA. The genes gelE, agg, ace and cpd were not detected among the isolates. The presence of Enterococcus sp. in water is a public health problem since it can spread virulent and antibiotic resistant bacteria to humans.
73

Tratamento de efluentes de lavagem de ônibus e de lavanderia por flotação por ar dissolvido e filtração visando o reúso de água / Laundry and bus washing effluent treatment by dissolved air flotation and filtration for water reuse

Araujo, Ana Paula Cosso Silva 17 February 2017 (has links)
Capes / A cadeia de transporte de ônibus intermunicipal e interestadual necessita de serviços associados à lavagem veicular e a lavanderia, para a lavagem de capas de poltronas e cobertores. Desta forma, este segmento demanda um elevado consumo de água, aliado a utilização de produtos químicos que podem comprometer a qualidade dos recursos hídricos. O reúso de água é uma técnica que visa reduzir o consumo de água potável para fins que não necessitem de tal qualidade. As empresas de transporte de ônibus podem implantar o sistema de reúso nas unidades de lavagem de ônibus. Entretanto, deve-se realizar um tratamento adequado do efluente para que a qualidade de água produzida não cause impacto negativo nas atividades da unidade onde está sendo reutilizada, bem como à saúde dos operadores. Assim, este trabalho teve como objetivo promover o tratamento de efluentes provenientes de uma empresa de transporte de ônibus rodoviário localizado na cidade de Londrina, Paraná. Os efluentes empregados neste trabalho são gerados nos setores de lavagem de ônibus e lavanderia, ambas atividades realizadas na empresa. Os sistemas de tratabilidade foram avaliados em escala de bancada, sendo estes: A) sistema de coagulação/floculação/FAD; B) coagulação/floculação/FAD seguido de pós-tratamento por filtração em meio granular sob pressão; C) coagulação/floculação/filtração em meio granular sob pressão e D) filtração direta em meio granular sob pressão, utilizando os coagulantes AQUAFLOC/LS e AQUA-PAC, visando o reúso do efluente tratado na lavagem dos ônibus. O delineamento estatístico aplicado aos ensaios de coagulação/floculação/FAD foi o Delineamento Composto Central Rotacional (DCCR). As variáveis independentes aplicadas foram: concentração do coagulante AQUAFLOC/LS, concentração do coagulante AQUA-PAC, concentração do polímero e pH de coagulação. As condições de coagulação/floculação aplicadas para os ensaios de FAD foram: Gmr 800 s-1, G1ml 90 s-1, G2ml 50 s-1 e G3ml 30 s-1, correspondendo aos tempos de rotação de 1; 10; 5 e 5 minutos, respectivamente. A Pressão na câmara de saturação foi de 6 bar, A Taxa de recirculação utilizada de 20% e as taxas de aplicação superficial foram 35, 70, 120 e 150 m3 m-2 dia-1. Para os ensaios de coagulação/floculação/filtração as condições de coagulação/floculação foram: Gmr 800 s-1 e G1ml 50 s-1. Para os ensaios de filtração, foi confeccionado um filtro de meio granular sob pressão em escala de bancada contendo como material filtrante areia e cascalho. Os sistemas de tratabilidade foram avaliados com relação à remoção de matéria orgânica, sólidos, nitrogênio, fósforo e surfactantes. Por meio da aplicação do método do DCCR determinou-se uma faixa ótima de atuação dos coagulantes no tratamento dos efluentes. Ao se promover a mistura dos efluentes de ambos os setores para posterior tratamento, a faixa ótima de concentração do coagulante AQUAFLOC/LS foi de 220 a 260 mg L-1 com pH de coagulação natural, enquanto que as faixas consideradas ótimas de concentração do AQUA-PAC estão entre 50 a 200 mg Al2O3 L-1 com pH de coagulação de 6,00 a 7,50 e entre 200 a 320 mg Al2O3 L-1 com pH de coagulação de 8,30 a 9,00. Para o tratamento do efluente da lavagem dos ônibus, a concentração ótima de AQUAFLOC/LS está entre 55 e 110 mg L-1 com pH de coagulação de 6,00 a 7,20, a concentração do AQUA-PAC variou entre 65 a 85 mg Al2O3 L-1 com pH de coagulação natural. Por fim, para o tratamento do efluente da lavanderia a faixa ótima de concentração do AQUAFLOC/LS variou entre 200 e 400 mg L-1 com pH de coagulação de 8,90 a 9,00, e para o AQUA-PAC a faixa ótima de concentração variou de 600 a 700 mg Al2O3 L-1 com pH de coagulação de 7,20 a 7,60. Ao se avaliar os diferentes sistemas de tratabilidade, verificou-se que os sistemas de coagulação/floculação/FAD seguido de filtração e coagulação/floculação/filtração empregando o coagulante AQUAFLOC/LS apresentaram os maiores índices de redução dos parâmetros analisados com eficiências de redução de DQO variando entre 73% a 81%, de turbidez entre 93% a 94%, de sólidos suspensos de 16% a 100% e de surfactante de 90% a 98%. O sistema de filtração em meio granular sob pressão possibilitou a obtenção de efluentes tratados passíveis de serem reutilizados em serviços de lavagem de ônibus. / The intercity and interstate bus transportation chain requires services associated with car wash and laundry, for the washing of armchairs covers and blankets. Thus, this segment demands high consumption of water, combined to the use of chemicals that can compromise the quality of water resources. Water reuse is a technique that aims to reduce the consumption of drinking water for purposes that do not require such quality. Bus companies can deploy a reuse system in their bus wash units. However, adequate effluent treatment must be carried out so that the quality of the water produced does not negatively impact the activities of the unit where it is being reused, as well as the operators’ health. Therefore, this work aimed to promote the effluents treatment from a bus transportation company located in the city of Londrina, Paraná. The effluents used in this work are generated in the bus washing and laundry sectors, both activities carried out in the company. The treatability systems were evaluated on bench scale, being these: A) coagulation/flocculation/DAF system; B) coagulation/flocculation/DAF followed by post-treatment by granular filter media filtration under pressure; C) coagulation/flocculation/granular filter media filtration under pressure and D) granular filter media direct filtration under pressure, using the AQUAFLOC / LS and AQUA-PAC coagulants, aiming at the reuse of the treated effluent on the buses wash. The statistical design applied to the coagulation/flocculation/DAF assays was the Central Rotational Composite Design (CRCD). The independent variables applied were: AQUAFLOC/LS coagulant concentration, AQUA-PAC coagulant concentration, polymer concentration and pH coagulation. The coagulation/flocculation conditions applied for the DAF assays were: Gmr 800 s-1, G1ml 90 s-1, G2ml 50 s-1 and G3ml 30 s-1, corresponding to the rotation times of 1; 10; 5 and 5 minutes, respectively. The pressure in the saturation chamber was 6 bar, the recirculation rate used was 20% and the rates of surface application were 35, 70, 120 and 150 m3 m-2 day-1. For the coagulation/flocculation/filtration tests, the coagulation/flocculation conditions were: Gmr 800 s-1 and G1ml 50 s-1. For the filtration tests, a bench scale granular filter under pressure was prepared containing sand and gravel filter material. The treatability systems were evaluated in relation to the organic matter removal, solids, nitrogen, phosphorus and surfactants. Through the application of the CCDR method, an optimum range of coagulant action in the effluent treatment was determined. By promoting the mixing of the effluents from both sectors for subsequent treatment, the optimum concentration range of the AQUAFLOC/LS coagulant varied from 220 to 260 mg L-1 with a natural coagulation pH, while the optimum concentration range of AQUA- PAC are between 50 and 200 mg Al2O3 L-1 with coagulation pH from 6.00 to 7.50 and between 200 and 320 mg Al2O L-1 with coagulation pH from 8.30 to 9.00. For the treatment of bus washing effluent, the optimum AQUAFLOC/LS concentration varied between 55 and 110 mg L-1 with coagulation pH from 6.00 to 7.20, the AQUA-PAC concentration ranged from 65 to 85 mg Al2O3 L-1 with natural coagulation pH. Finally, for the laundry effluent treatment, the optimum AQUAFLOC/LS concentration range varied from 200 to 400 mg L-1 with a coagulation pH from 8.90 to 9.00, and for AQUA-PAC, the optimum range concentration varied from 600 to 700 mg Al2O3 L-1 with 11 coagulation pH from 7.2 to 7.6.When evaluating the different treatability systems, it was verified that the coagulation/flocculation/DAF systems followed by filtration and coagulation/flocculation/filtration using the AQUAFLOC/LS coagulant presented the highest reduction indices of the analyzed parameters with reduction efficiencies of COD ranging from 73% to 81%, turbidity between 93% and 94%, suspended solids from 16% to 100% and surfactant from 90% to 98%.The granular filter media filtration system under pressure made it possible to obtain treated effluents that could be reused in bus washing services.
74

Composição microbiológica cultivável do granizo de uma tempestade no sudoeste do Paraná / Cultivable microbiological composition of hail from a Paraná state southwestern storm

Tsay, Gabriela Salles 28 July 2017 (has links)
A queda de granizo é um fenômeno muito recorrente nas tempestades que atingem a Região Sul do Brasil, região do país que registra a maior incidência do fenômeno. Ainda assim, pouca investigação científica foi conduzida até o momento para se compreender as principais características do fenômeno e os mecanismos nele envolvidos. Desta forma, o presente trabalho tem como objetivo apresentar, pela primeira vez, uma caracterização da composição microbiológica cultivável do granizo de uma tempestade ocorrida no sudoeste do estado do Paraná. Após terem seus diâmetro, massa e volume mensurados fisicamente, amostras de granizo de uma tempestade ocorrida em julho de 2016 foram submetidas a um protocolo de descontaminação estabelecido neste trabalho, e cultivadas em meio MHA para o isolamento de bactérias. As UFC foram caracterizadas e contabilizadas e os 76 isolados representativos obtidos foram submetidos a análise morfotintorial com a técnica coloração de Gram. Um agrupamento fenotípico utilizando o software UPGMA permitiu a seleção de 22 isolados representativos para serem enviados ao sequenciamento genético. O DNA total destes isolados foi extraído por kit comercial e na sequência foi realizada PCR para amplificação da região 16S de RNA ribossômico (RNAr). O amplicon gerado foi encaminhado para sequenciamento em empresa especializada, e as sequências genéticas obtidas foram submetidas a buscas de similaridades com sequências gênicas presentes no GenBank, por meio do BLAST. Como resultado foram identificadas 11 espécies de bactérias pertencentes a 8 gêneros distintos, todas características de ambiente natural, com predominância de espécies em formato de bacilo, Gram-positivas e formadoras de esporos. Os gêneros Bacillus e Paenibacillus representaram 50% das espécies identificadas e foram apontados em outros estudos como potenciais nucleadores de gelo. Identificou-se ainda o gênero Sporosarcina como o único não encontrado em buscas feitas na literatura para estudos relacionados a amostras de ar, água de nuvem ou granizo. Com relação às propriedades físicas, as pedras de granizo apresentaram diâmetros médios entre 1,15 e 1,75cm, e densidades médias variando entre 0,8 a 1,0g/mL, condizentes com a literatura. Por fim, sugestões para estudos futuros foram apresentadas nas conclusões. / The hailfall is a recurrent phenomenon in storms that reach Brazil´s South Region. Nevertheless, little scientific investigation has been conducted in order to understand the main characteristics and involved mechanisms. Physical, chemical and microbiological characterization of hailstones consists on an important stage to understand processes associated to events that culminate in hail. Thus, this work aims to present, for the first time, a characterization of microbiological composition of hail from a hailstorm occurred in southwestern of Paraná state. Hailstones from a storm occurred in July 2016 were physically characterized (mass, diameter, volume, density), and submitted to a decontamination protocol established in this work. Melt hailstone water was plated to grow in MHA medium for bacteria isolation. We counted and characterized CFU, resulting in 76 representative isolates that were submitted to morphotintorial analysis by Gram stain technique. UPGMA software delivered a phenotypic grouping that enabled the selection of 22 representative isolates to be forwarded to the genetic sequencing service. We extracted total DNA from these isolates by commercial extraction kit and performed a PCR for amplification of ribosomal RNA (rRNA) 16S region. A specialized company provided the genetic sequences to the generated amplicon. The genetic sequences were submitted to BLAST for similarity search in GenBank. As a result, we identified 8 genera and 11 species of environmental bacteria, which were predominantly rod-shaped, Gram-positive, and spore-forming. Bacillus and Paenibacillus represented 50% of the species identified and they were mentioned in other studies as potential ice nucleators. Sporosarcina was the only genus that could not be found in our literature searches regarding air, cloud water or hail samples. Regarding the physical properties, hailstones had average diameters between 1.15 and 1.75cm, and mean densities ranging from 0.8 to 1.0g / mL, consistent with the literature. Finally, we present suggestions for future studies in the conclusion.
75

Avaliação de cobre e zinco em água, sedimento e peixes do rio Apucaraninha na região da terra indígena Apucarana (Tamarana, PR) / Copper and zinc evaluation in water, sediment and fish of Apucaraninha river in the area of Apucarana indigenous land (Tamarana, PR)

Dornelles, Fernanda Nasser 12 September 2016 (has links)
As concentrações médias (mg/kg) de Cobre (Cu) e Zinco (Zn) foram determinadas em amostras de água e sedimento coletadas no rio Apucaraninha no inverno de 2015 e no verão de 2016 em pontos a montante da Terra Indígena Apucarana (Tamara – PR), em função do uso e ocupação do solo potencialmente poluidores do rio no âmbito do território mencionado. Foram determinadas também as concentrações médias de Cu e Zn nas espécies Astyanaxaltiparanae, OligosarcusparanensiseGeophagus brasiliensis coletadas junto à comunidade indígena, conforme suas próprias rotinas de pesca. Foram analisadas as variações das concentrações de Cu e Zn nos sedimentos nos diferentes pontos de amostragem. Na espécie A. altiparanae foram analisadas as variações nas concentrações de Cu e Zn entre diferentes classes de tamanho e entre os anos de coleta (2013, 2015 e 2016). As concentrações de Cu nas amostras de água e nos peixes estiveram abaixo do limite de detecção da técnica de análise. No sedimento, as concentrações de Cu estiveram acima do níveldo nível abaixo do qual se prevê baixa probabilidade de efeitos adversos à biota estabelecido por Resolução do Conselho Nacional do Meio Ambiente (CONAMA) nº 344 de 2004, enquanto às de Zn se revelaram inferiores a mesma Resolução. Houve variação significativa entre os pontos de amostragem. As três espécies de peixes analisadas apresentaram concentrações de Zn acima do limite permissível para peixes e produtos de pesca segundo a Portaria nº 685 de 1998 da Secretária de Vigilância Sanitária do Ministério da Saúde (BRASIL, 1998). Houve variações significativas nas concentrações entre diferentes classes de tamanho da espécie A. altiparanae, bem como decréscimo acentuado entre os anos de 2013 e 2016, o qual pode estar relacionado com o esvaziamento do reservatório em 2014, que influenciou os níveis desse elemento traço no material sedimentado e, dessa forma, na sua biodisponibilidade para a biota. A despeito do Cu e Zn serem metaismicroessenciais, ambos estão presentes nesse recurso hídrico em níveis que despertam a atenção quanto aograu de contaminaçãoambiental desse meio. Na localidade estudada essa exposição é preocupante, pois os peixes compõem a rotina alimentar da comunidade indígena, uma vez que a prática da pesca é muito comum entre as famílias, sendo parte essencial da sua cultura e subsistência. / Average concentrations (mg/kg) of copper (Cu) and zinc (Zn) were determined in water and sediment samples collected in Apucaraninha river in winter 2015 and summer 2016 at downstream sites of Indigenous Land Apucarana (Tamara - PR), depending on the potentially polluting use and occupation of the basin in the mentioned territory. They also determined the average concentrations in the species Astyanaxaltiparanae, Oligosarcusparanaense and Geophagusbrasiliensis collected by the indigenous community from their fishing routines. The variations between the concentrations of Cu and Zn were analyzed in the sediment at different sites. Variations in the concentrations of Cu and Zn were analyzed in the species A. altiparanaeamong different size classes and the sampling years (2013,2015 and 2016).The concentration of Cu in the samples of water and fish were below the detection limit of the analytical technique. In the sediment, the Cu concentrations were above the level, while the Zn proved lower level below which provides low probability of adverse effects to biota established by Resolution of the National Environmental Council (CONAMA), revealing significant variation between sampling sites. The three species of fish analyzed showed Zn concentrations above the allowable limit for fish and fishery products according to Ordinance No. 685 of 1998 of the Secretary of Health Surveillance, Ministry of Health. There were significant variations in concentrations among different size classes of A. altiparanae and decrease along of the years 2013 to 2016, which may be related to the emptying of the reservoir in 2014, which influenced the levels of this trace element in the material sedimented. Despite the Cu and Zn are micronutrients trace metals, both are present in this hydric resources at levels that attract the attention by the degree of environmental contamination of the basin. In the studied locality this exposure is worrisome because fish make up the feeding routine of the indigenous community, since the practice of fishing is very common among families, being an essentntl component of their culture and livelihood.
76

Avaliação dos efeitos da contaminação de cobre no solo sobre Mentha crispa L. / Evaluation of the effects of copper contamination in soil on Mentha crispa L.

Boldarini, Maria Theresa Bettin 23 February 2017 (has links)
Fundação Araucária / O estudo realizado neste trabalho visou avaliar os efeitos causados na Menta crispa L., cultivada em solos contaminados com doses crescentes de cobre. O experimento foi realizado com oito concentrações diferentes de cobre em cinco replicatas, totalizando 40 amostras. Realizou-se o estudo sob condições naturais de luz e temperatura, em casa de vegetação no intervalo de julho a setembro de 2016, respeitando o período de 120 dias de crescimento da Mentha crispa L. Foram realizadas análises físicas e químicas do solo, caracterizando-o como Latossolo Vermelho Distroférrico, e foi determinada a capacidade máxima de adsorção de cobre (529,03 mg kg-1) no solo a partir da Isoterma de Freundlich. A partir da capacidade máxima, foram definidas as concentrações de cobre utilizadas no experimento, de C0 a C7, sendo C0 sem adição de cobre (controle), C1 com 1/8 da capacidade máxima, C2 com 1/6, C3 com 1/4, C4 com 1/2, C5 capacidade máxima, C6 o dobro e C7 o quádruplo. Durante o período determinado para o experimento foram realizadas contagens quinzenais do número de folhas e brotos, assim como a medição do comprimento da planta e a sintomatologia visual. Passado este período a planta foi retirada do recipiente, devidamente limpa e seca, seguindo para preparação e digestão das amostras. Realizou-se a determinação de cobre usando um espectrômetro de absorção atômica com atomização em forno de grafite, com correção de fundo baseado no efeito Zeeman e auxílio de modificador permanente (Paládio). Foram calculados os fatores de Bioacumulação e Translocação para cobre na Mentha crispa L e foram realizadas análises estatísticas ANOVA e MANOVA para análise e validação dos resultados encontrados. Observou-se durante o período de cultivo os efeitos como clorose e diminuição no crescimento da planta, nas concentrações mais altas de cobre. A redução no crescimento em relação ao controle variou de 20 a 25%; a diminuição no número de brotos e folhas chegou a 40% para C7 para ambos os parâmetros. Considerando a concentração do metal na menta, este se acumula principalmente nas raízes, sendo aproximadamente 6 vezes maior em C6 e C7 do que no controle (C0). Para os fatores de bioacumulação e translocação, os valores encontrados foram menores que 1, o que caracteriza a planta como sendo tolerante ao metal e mostrando que o mesmo fica retido na raiz. Nas maiores concentrações, C6 e C7, o acúmulo médio do metal foi de 235 mg.kg-1, valor muito superior ao considerado tóxico pelos padrões europeus de limite seguro de concentração de cobre em solo (140 mg.kg-1). Os resultados apresentados indicam fortemente o potencial da Mentha crispa L. como planta fitoestabilizadora, podendo ser utilizada como opção para a retirada do excesso de Cu do solo, fato que pode ser de suma importância às lavouras e o desenvolvimento das plantas em geral. / The objective of this study was to evaluate the effects of copper on Mentha crispa L., cultivated in soils contaminated with increasing doses of this metal. The experiment was carried out with eight different concentrations of Cu in five replicates, totalling 40 samples. The study was carried out under natural light and temperature conditions, in the vegetation house, from July to September 2016, respecting the 120-day growth period of Mentha crispa L.. Soil analyses were carried out to verify the physical and chemical factors characterizing the soil (Dystroferric Red Latosol), to determine the maximum Cu adsorption capacity (529.02877 mg kg-1) through the Freundlich's isotherm. From the maximum adsorption, was defined the increasing doses of contamination used in the experiment, C0 to C7, were C0 without addition of copper (control), C1 with 1/8 of the maximum capacity, C2 with 1/6, C3 with 1/4, C4 with 1/2, C5 maximum capacity, C6 double and C7 quadruple. During the period determined for the experiment, biweekly counts of the number of leaves and shoots were taken, as well as the measurement of plant length and visual symptomatology. After this period, the plant was removed from the pot, duly cleaned and dried, for then, prepare and digest the samples. The copper determination was carried out using a graphite furnace atomic absorption spectrometer, and background correction based on the Zeeman effect, with the aid of a permanent modifier (Palladium). Bioaccumulation and Translocation Factor was calculated for copper on Mentha crispa L. and statistical analysis, ANOVA and MANOVA, were carried out to analysis and validation of the results found. Effects such as chlorosis and decrease in plant growth were observed during the growing period at the highest concentrations of copper. The reduction in growth in relation to the control ranged from 20 to 25%. The decrease in the number of shoots and leaves reached 40% for C7 for both parameters. Considering the concentration of the metal in the peppermint, it accumulates mainly in the roots, being approximately six times greater in C6 and C7 than in the control (C0). For FB and FT the values found were lower than 1, which characterizes the plant as being tolerant to the contaminant and showing that it is retained in the root. At the highest concentrations C6 and C7, the average metal accumulation was 235 mg.kg-1, which is much higher than the Europeans safe limits for copper in soil (140 mg.kg-1). The results presented strongly indicate the potential of Mentha crispa L. as a phytostabilizing plant, and can be used as an option for the removal of excess Cu from the soil, a fact that can be of great importance to the crops and the development of the plants in general.
77

Sistema alagado construído como pós-tratamento do flotador de indústria de laticínios / Constructed wetlands as post treatment of the dairy industry float

Oliveira, Danielle Martins Cassiano de 22 February 2017 (has links)
Capes / A indústria de laticínios utiliza grande quantidade de água para sua produção, em consequência deste fato, gera proporcionalmente elevadas quantidades de efluentes em suas atividades. As águas residuárias dos processos envolvidos em laticínios, possuem alta carga de matéria orgânica e de nutrientes como nitrogênio e fósforo. Os Sistemas Alagados Construídos (SAC) são uma opção de baixo custo de manutenção e operação, além de serem eficazes em sistemas de tratamento de efluentes. Desta forma, foi construído um sistema alagado construído de fluxo vertical, com fundo saturado em escala piloto em uma indústria de laticínios no município de Londrina. As dimensões do SAC foram de 0,6 x 1,7 x 2,6 m, preenchido com substrato de brita 0 (perfil de 0,20 m), 1 (perfil de 0,25 m) e 2 (perfil de 0,15 m) de forma descendente. O tempo de detenção hidráulico utilizado para dimensionamento de 3 dias com taxa de irrigação média de 60 L.d-1.m-2. Utilizou-se a planta Cyperus papyrus para realizar o tratamento do efluente de laticínio proveniente do flotador por ar dissolvido (FAD) da indústria, que removia a alta carga orgânica presente no efluente. As variáveis estabelecidas para este trabalho foram cor aparente, turbidez, demanda química de oxigênio (DQO), pH, condutividade elétrica, alcalinidade, série de sólidos, nitrogênio total (NTK) e fósforo total. Cartas de controle foram utilizadas para verificar se o processo estava sob controle estatístico. No FAD, as variáveis que estiveram sob controle foram o fóforo, sólidos totais, sólidos dissolvidos e sólidos suspensos; no SAC foram a condutividade elétrica, turbidez, DQO, e sólidos suspensos. O índice de capacidade de processo (Cp) foi aplicado aos parâmetros de pH, DQO, fósforo total, NTK e sólidos suspensos para verificar se o tratamento foi capaz de atender aos padrões de lançamento especificados pela legislação ambiental. As variáveis capazes de atender a legislação foram o pH e os sólidos suspensos. Ensaios hidrodinâmicos do SAC foram realizados ao longo do processo de tratamento para avaliar a vazão e a colmatação durante o experimento. Não foi constatada colmatação no SAC. Também foi avaliado o crescimento das plantas no meio filtrante como efluente tratado advindo do FAD. Pode-se averiguar que as macrófitas se adaptaram ao sistema com um crescimento adequado. Os resultados obtidos de eficiência do SAC permitem concluir que o sistema é capaz de remover a matéria orgânica após o FAD, porém não apresenta controle de processo nas demais variáveis analisadas. / The dairy industry uses a large amount of water for its production. As a consequence, it generates proportionally high amounts of effluent in its activities. Wastewater from processes involved in dairy products has high organic matter and nutrients such as nitrogen and phosphorus. Constructed Alachate Systems (SACs) are a low-cost option for maintenance and operation, as well as being effective in effluent treatment systems. In this way, a flood system was installed, built with a vertical flow, with a saturated bottom on a pilot scale in a dairy industry in the city of Londrina. SAC dimensions were 0.6 x 1.7 x 2.6 m, filled with substrate gravel 0 (profile of 0.20 m), 1 (profile of 0.25 m) and 2 (profile of 0, 15 m) in descending order. The hydraulic detention time used for 3-day sizing with an average irrigation rate of 60 L.d-1.m-2. The Cyperus papyrus plant was used for the treatment of the dairy effluent from the float by dissolved air (FAD) of the industry, in order to remove the high organic load present in the effluent. The variables established for this work were apparent color, turbidity, chemical oxygen demand (COD), pH, electrical conductivity, alkalinity, solids series, total nitrogen (NTK) and total phosphorus. Control charts were used to verify if the process was under statistical control. In the FAD, the variables that were under control were the phosphorus, total solids, dissolved solids and suspended solids; In SAC were the electrical conductivity, turbidity, COD, and suspended solids. The process capacity index (Cp) was applied to the pH, COD, total phosphorus, NTK and suspended solids parameters to verify if the treatment is able to meet the release standards specified by the environmental legislation. The variables capable of complying with the legislation were pH and suspended solids. SAC hydrograph tests were carried out along the treatment process to evaluate the flow and the filling during the experiment, without verification of the sealing process in the SAC. The growth of the plants in the filter medium as treated effluent from FAD was also evaluated. It can be verified that macrophytes have adapted to the system with adequate growth. The results of SAC efficiency allow to conclude that the system is able to remove organic matter after FAD, but does not present process control in the other analyzed variables.
78

Influência da vazão e da posição do jato de água na transferência de oxigênio por tubos venturi / Influence of flow rate and water jet position on oxygen transfer by venturi tubes

Gianjacomo, Carlos Henrique 28 April 2017 (has links)
O objetivo desse trabalho foi avaliar o potencial de reoxigenação da água por meio de tubos de Venturi. Os experimentos foram realizados em dois tanques: horizontal (TH) e vertical (TV), com volumes úteis de 100 L e 63 L, respectivamente. Os testes seguiram delineamento experimental associado a metodologia de superfície de respostas, tendo como variáveis independentes a vazão da água (Qágua) e a posição de entrada do jato (Pjato), para um único tubo de Venturi e dois tubos associados em paralelo. Como respostas, foram determinados os coeficientes globais de transferência de oxigênio do ar para a água (KLa) e as eficiências de oxigenação (EO). Os resultados indicam que a vazão da água influenciou significativamente os valores de KLa e EO, enquanto que a posição do jato só teve efeito quando os tubos de Venturi foram associados em paralelo, em ambos os tanques. De maneira geral, os melhores resultados do KLa, de até 50 h-1, foram obtidos para vazões de água mais elevadas e a jato posicionado 15 cm acima da superfície da água. Eficiências de oxigenação de até 2 kgO2 kW-1 h-1 foram observadas para baixos valores de vazão de água. Considerando-se valores experimentais de densidade de potência (DP) e volume de ar injetado por minuto na massa de água, o tanque vertical apresentou desempenho de KLa e EO ligeiramente superior ao horizontal. Os dados experimentais podem ser satisfatoriamente representados pelos modelos matemáticos obtidos. / The objective of this work was to evaluate the reoxygenation potential of water using Venturi tubes. The experiments were performed in two tanks: Horizontal (HT) and vertical (VT), with useful volumes of 100 L and 63 L, respectively. The tests followed the statistical design associated with the surface methodology of responses, having as independent variables the water flow (Qwater) and the inlet position of the jet (Pjet), for a single Venturi tube and two associated tubes in parallel. Were determined as response the global oxygen transfer coefficients from air to water (KLa) and oxygenation efficiencies (OE). The results indicate that the water flow significantly influenced the values of KLa and OE, whereas the position of the jet only had effect when the Venturi tubes were associated in parallel, in both tanks. In general, the best KLa results, up to 50 h-1, were obtained for higher water flows and a jet positioned 15 cm above the water surface. Oxygenation efficiencies of up to 2 kgO2 kW-1 h-1 were observed at low water flow rates. Considering experimental values of power density (DP) and volume of air injected per minute, the vertical tank showed a performance of KLa and EO slightly higher than vertical. The experimental data can be satisfactorily represented by the mathematical models obtained.
79

Avaliação do desenvolvimento de Mentha crispa L. em solo contaminado com cádmio / Evaluation of the development of Mentha crispa L. on soil contaminated with cadmium

Zemiani, Adriana 23 February 2017 (has links)
Capes / O objetivo deste trabalho foi avaliar o desenvolvimento de Mentha crispa L. (Hortelã Jardim) em um solo contaminado com diferentes concentrações de Cd. O delineamento experimental foi feito em cinco repetições, distribuído em oito tratamentos (C0(controle), C1(1,15 g.kg-1), C2(1,53 g.kg-1), C3(2,30 g.kg-1), C4(4,60 g.kg-1), C5(9,21 g.kg-1), C6(18,25 g.kg-1) e C7(36,87 g.kg-1)). O tratamento C5 usou a concentração máxima de metal absorvido pelo solo, determinado pela isoterma de adsorção usando o modelo de Langmuir. As plantas foram cultivadas durante 120 dias, no período de junho a agosto de 2016, e a cada 15 dias foram coletados dados como altura, número de folhas e número de brotos. Foram feitos registros para avaliação da sintomatologia visual observando o comportamento da planta em cada tratamento ao longo do período de experimento. Ao final do tratamento as plantas foram coletadas e separadas em três partes (folhas, caule e raiz) e submetidas à digestão ácida assistida por micro-ondas para determinação de cádmio através da Espectrometria de Absorção Atômica. Observou-se que a altura, número de brotos e número de folhas diminuíram conforme aumentavam as concentrações de Cd nos tratamentos. Sintomas da toxicidade do Cd foram observados nas plantas, como: clorose, envergamento da folha e murchamento. As plantas do tratamento C6 e C7 morreram com 48 horas em contato com solo contaminado. Considerando a quantidade total de cádmio absorvida pela planta, a maior parte foi retida pelas raízes e uma parte insignificante foi translocada para a parte aérea (caule e folhas). O fator de bioacumulação calculado em todos os tratamentos foi maior que um, indicando que a planta é capaz de acumular Cd. O fator de translocação da planta foi menor que um em todos os tratamentos, demonstrando que apesar de a Mentha crispa L. acumular Cd, ela não pode ser classificada como hiperacumuladora e sim como Fitoestabilizadora. Portanto, a Mentha crispa L. pode ser usada para imobilizar o metal em locais contaminados. O fato do metal praticamente não ter sido translocado para a parte aérea pode ser um ponto favorável na escolha da planta para ser usada na fitorremediação, já que a Mentha crispa L., do ponto de vista econômico, pode ter valor agregado na extração do óleo essencial que é produzido pelas folhas. / The objective of this work was to evaluate the behavior of Mentha crispa L. (Garden Mint) in a soil contaminated with different concentrations of Cd. The experimental design was done with five replicates distributed in eight treatments (C0 (control), C1 (1.15 g.kg-1), C2 (1.53 g.kg-1), C3 (2.30 g.kg-1), C4 (4,60 g.kg-1), C5 (9.21 g.kg-1), C6 (18.25 g.kg-1) and C7 (36.87 g.kg-1)). The C5 treatment used the maximum concentration of metal absorbed by the soil, determined through the adsorption isotherm using the Langmuir equation model. The plants were cultivated for 120 days, from June to August 2016, and every 15 days data were collected such as height, number of leaves and number of shoots. Records were made to evaluate the visual symptomatology observing the behavior of the plant in each treatment throughout the experiment period. At the end of the treatment the plants were collected and separated into three parts (leaves, stem and root) and submitted to microwave assisted acid digestion to determine cadmium through Atomic Absorption Spectrometry. It was observed that the height, number of shoots and number of leaves decreased as the concentrations of Cd increased in the treatments. Symptoms of Cd toxicity were observed in plants, such as: chlorosis, leaf blight and wilting. Plants fromC6 and C7 treatments died within 48 hours after contact with contaminated soil. Considering the total amount of cadmium absorbed by the plant, most were retained by the roots and an insignificant part was translocated to the aerial part (stem and leaves). The bioaccumulation factors were calculetd in all treatments and they was greater than one, indicating that the plant is able to accumulate Cd. The plant translocation factor was lower than one in all treatments demonstrating that although a Mentha crispa L. accumulates Cd, it can not be classified as hyperaccumulating, but as phytoextabilizing. Therefore, the Mentha crispa L. can be used to immobilize the metal in contaminated sites. The fact that the metal has pratically not been translocated to the aerial part can be a favorable point in the choice of the plant to be used in the phytoremediation, since the Mentha crispa L., from the economic point of view, may have added value in the extraction of the essential oil, which is produced by the leaves.
80

Consumo de pescado proveniente do Lago Igapó (Londrina/PR) por pescadores amadores: uma eventual exposição à contaminação por chumbo / Consumption of fish from Lake Igapó (Londrina/PR) by amateur fishermen: possible exposure to lead contamination

Silva, Cassiano Andrade 26 April 2017 (has links)
A crescente poluição ambiental nas últimas décadas vem tornando os metais tóxicos uma ameaça constante aos seres vivos. Entre estes, o chumbo é um dos mais importantes, devido à quantidade de áreas contaminadas e seus efeitos deletérios para saúde humana. Determinadas espécies de pescado representam valiosos aliados na nutrição humana e, por serem considerados um importante recurso proteico e fazerem parte da composição alimentar humana, os peixes representam uma das principais fontes de ingestão de metais para o homem via cadeia alimentar. Estudos prévios identificaram a presença de chumbo em concentrações acima do nível permitido pela legislação em diversos pontos ao longo do Ribeirão Cambé, na cidade de Londrina/PR. Devido à importância do Lago Igapó para a população local para a prática de atividades de pesca e recreação, o presente estudo teve como objetivo analisar o potencial de contaminação por chumbo que esta população que utiliza o pescado proveniente do local para consumo pode, eventualmente, estar sendo exposta. Com a finalidade de avaliar aspectos socioeconômicos, hábitos de pesca, analisar quantitativa e qualitativa do produto de pesca, foram aplicados questionários com os praticantes de pesca amadora no Lago Igapó e realizada a biometria e identificação das espécies capturadas pelos entrevistados. A análise dos dados mostrou que 59% dos entrevistados praticavam a pesca de subsistência, visando exclusivamente o consumo do pescado. Além disso, 15% dos pescadores revelaram fazer a pesca recreativa e, eventualmente, o consumo do produto da pesca. A frequência de consumo de peixe entre os entrevistados também foi alta (2,35 dias/ semana), sendo este consumo de origem praticamente exclusiva do Lago Igapó (2,20 dias/ semana). Dentre as espécies identificadas, Tilapia rendalli foi consideravelmente mais abundante (quase 90% dos exemplares), o que mostra que esta espécie é uma das mais consumidas pelos pescadores locais. Esse dado é preocupante visto que estudos prévios realizados no Lago Igapó mostraram concentração de chumbo cerca de 13 vezes acima do limite permitido pela legislação nessa espécie. Os resultados refletem a importância do produto da pesca proveniente do Lago Igapó como fonte de proteína na alimentação dos pescadores e sua família e confirma a preocupação relativa à eventual exposição da população à contaminação por chumbo. / Increasing environmental pollution in recent decades has made toxic metals a constant threat to living creatures. Lead is among the most important ones due to contaminated areas extension and its deleterious effect on human health. Certain fish species are very important to human nutrition because they are considered a major protein source and are part of human food composition. Fish represent one of the main sources of metal intake for humans in the food chain. Previous studies have identified lead presence in concentrations above the maximum level admitted by the legislation at several points along the Ribeirão Cambé, in the city of Londrina / PR Brazil. As Lake Igapo is important to the local population for fishing and recreation activities, the present study aims to analyze the potential lead contamination that this population could be exposed when fishing and consuming fishes from the lake. A questionnaire was designed to evaluate socioeconomic aspects and fishing habits, a quantitative and qualitative analysis was done. Amateur fishermen of Lago Igapó answered the questionnaire, and biometrics and identification of the specimens captured by the interviewees were carried out. Data shows that 59% of the interviewees practice subsistence fishing, oriented to fish consumption exclusively. In addition, 15% of fishermen have revealed that they are engaged in recreational fishing and consume the fishery product occasionally. Interviewees fish consumption frequency is high (2.35 days / week), and this consumption is primarily from Lago Igapó (2.20 days / week). Tilapia rendalli is considerably more abundant (almost 90% of the specimens) among the species identified; it shows that this species is one of the most consumed by local fishermen. This data is worrisome once previous studies showed a lead concentration around thirteen times the limit allowed by the legislation for this species. The result reflects the importance of the fishery product from Lake Igapó as a source of protein in the diet of fishermen and their families and confirms the concern regarding the possible exposure of the population to lead contamination.

Page generated in 0.0411 seconds