• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • Tagged with
  • 9
  • 9
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Use of quantitative trait loci (QTL) affecting muscling in sheep for breeding

Masri, Amer January 2013 (has links)
Breeding programmes that use elite sires with the best estimated breeding values for muscling traits have achieved significant improvement in lamb production in the UK. Further acceleration of the rate of genetic gain for the desirable production traits could be achieved using DNA marker-assisted selection (MAS) breeding strategies. The underlying causal genetic variants associated with improved muscling may be unknown and lying between a cluster of genes known as quantitative trait loci (QTL) or could be single nucleotide polymorphisms (SNP). LoinMAXTM, Texel muscling QTL (TM-QTL) and c.*1232G > A myostatin mutation were genetic variants that reported to be associated with improved muscling characteristics and hence subjected to further analysis in this project. It is essential before incorporating segregating genetic variants in any breeding scheme to comprehensively evaluate their effects on carcass traits. In-vivo scanning (ultrasound scanning (US) and computed tomography scanning (CT)), and carcass video image analyses (VIA) were used in the current studies. Objective VIAprediction weights of the carcass primal cuts could be the backbone of a value-based marketing system that is suggested to replace the current Meat and Livestock Commission (MLC) carcass grades for conformation scores (MLC-C) and fat class (MLC-F). The effect of a single copy of LoinMAXTM QTL (LM-QTL) compared to noncarriers was evaluated in UK crossbred lambs out of Scottish Mule ewes. M. longissimus lumborum (MLL) width, depth and area, as measured by CT scanning, were significantly greater in lambs heterozygous for LM-QTL compared to noncarriers. VIA detected a significant effect of the LM-QTL on the predicted weight of saleable meat yield in the loin primal cut (+2.2%; P < 0.05). The effects of the ovine c.*1232G > A myostatin mutation (MM), found on sheep chromosome 2, on carcass traits in heterozygous crossbred lambs sired by Texel and Poll Dorset rams were studied. Texel crossbred lambs carrying MM had increased loin depth and area. In both crossbred lambs, MM-carriers had significantly higher CT-estimated lean weight and proportion (2 to 4%) and muscle to bone ratios (by ~3%). Poll Dorset heterozygous crossbred animals had higher muscle to fat ratio (28%) and significantly lower fat-related measurements. The c.*1232G > A (MM) mutation as well as TM-QTL effects were evaluated in a different genetic background of Texel x Welsh Mountain crossbreed lambs. Carrying two copies of MM was associated with a significant positive effect on 8 week weight, a negative effect on ultrasound fat depth, a substantial decrease in MLC-fat score, positive impact on VIA-estimated weight of the hind leg, chump and loin primal cuts, as well as the muscularity of the hind leg and loin regions with greater loin muscle width, depth and area. Two copies of MM altered lambs‟ morphological traits with significantly wider carcasses across the shoulders, breast and hind legs and greater areas of the back view of the carcass when measured by VIA. TM-QTL significantly increased US-muscle depth and TM-QTL carriers had significantly greater loin muscle width and area measurements. Comparing TM-QTL genetic groups (homozygote allele carriers (TM/TM), heterozygote carriers of paternal and maternal origin of allele (TM/+ and +/TM, respectively) and homozygote non-carriers (+/+)) and TM-QTL mode of action were then studied. TM/TM carcasses were significantly heavier than non-carriers by 1.6 kg and scored higher conformation values when compared to heterozygote groups only. TM/+ lambs had significantly higher VIA-predicted weight and muscularity in the hind leg and loin, and higher loin dimensions relative to some other genotypic groups. The effect of TM-QTL on some carcass shape measurements was significant. TM-QTL mode of action results on the loin muscling traits supports the earlier reports of polar over dominance. In the light of growing calls to replace the current subjective carcass payment system with the objective VIA system that values the carcass according to the superiority of its cuts, I investigated the ability of US and CT measurements to predict the VIAestimated weights of the carcass primal cuts. Several prediction equations were examined but the best could be achieved when ultrasound measurement, CT linear measurements and live weight were fitted in the model. Since CT scanning information of elite sires is now being used for genetic selection for carcass merit, genetic parameters and genetic relationships between CT scanning measurements and post mortem traits (VIA and MLC-FC) were estimated. However, results were not sufficiently accurate to be of practical use due to lack of data.
2

Novel Methods for Reducing Breast Dose During Computed Tomography Scans

January 2011 (has links)
Pediatric female and young adult female patients who undergo computed tomography (CT) scanning may be at higher risk for developing radiation-induced breast cancer later in life. Thus, the purpose of this thesis was to both accurately quantify dose and explore new strategies for CT breast dose reduction. In order to determine dose reduction, dose quantification was first assessed through the development and validation of an empirical model for describing attenuation in CT and second through evaluation of the precision of dosimetry-related measurements obtained using three different models of CT scanners. Breast dose-savings was evaluated using CT dose index phantoms, anthropomorphic phantoms, and Monte Carlo computer modeling. Modifications to current scanning procedures, such as proper patient centering and beginning data acquisition with the x-ray tube facing a patient's posterior, were shown to minimize breast dose. Novel techniques, including varying the x-ray tube voltage during scanning and incorporation of a dynamic x-ray beam filter over the breasts, were also found to successfully reduce breast dose.
3

Imaging calcification in aortic stenosis

Pawade, Tania Ashwinikumar January 2018 (has links)
BACKGROUND Aortic stenosis is a common and potentially fatal condition in which fibro-calcific changes within the valve leaflets lead to the obstruction of blood flow. Severe symptomatic stenosis is an indication for aortic valve replacement and timely referral is essential to prevent adverse clinical events. Calcification is believed to represent the central process driving disease progression. 18F-Fluoride positron emission tomography computed tomography (PET-CT) and CT aortic valve calcium scoring (CT-AVC) quantify calcification activity and burden respectively. The overarching aim of this thesis was to evaluate the applications of these techniques to the study and management of aortic stenosis. METHODS AND RESULTS REPRODUCIBILITY The scan-rescan reproducibility of 18F-fluoride PET-CT and CT-AVC were investigated in 15 patients with mild, moderate and severe aortic stenosis who underwent repeated 18F-fluoride PET-CT scans 3.9±3.3 weeks apart. Modified techniques enhanced image quality and facilitated clear localization of calcification activity. Percentage error was reduced from ±63% to ±10% (tissue-to-background ratio most-diseased segment (MDS) mean of 1.55, bias -0.05, limits of agreement - 0·20 to +0·11). Excellent scan-rescan reproducibility was also observed for CT-AVC scoring (mean of differences 2% [limits of agreement, 16 to -12%]). AORTIC VALVE CALCIUM SCORE: SINGLE CENTRE STUDY Sex-specific CT-AVC thresholds (2065 in men and 1271 in women) have been proposed as a flow-independent technique for diagnosing severe aortic stenosis. In a prospective cohort study, the impact of CT-AVC scores upon echocardiographic measures of severity, disease progression and aortic valve replacement (AVR)/death were examined. Volunteers (20 controls, 20 with aortic sclerosis, 25 with mild, 33 with moderate and 23 with severe aortic stenosis) underwent CT-AVC and echocardiography at baseline and again at either 1 or 2-year time-points. Women required less calcification than men for the same degree of stenosis (p < 0.001). Baseline CT-AVC measurements appeared to provide the best prediction of subsequent disease progression. After adjustment for age, sex, peak aortic jet velocity (Vmax) ≥ 4m/s and aortic valve area (AVA) < 1 cm2, the published CT-AVC thresholds were the only independent predictor of AVR/death (hazard ratio = 6.39, 95% confidence intervals, 2.90-14.05, p < 0.001). AORTIC VALVE CALCIUM SCORE: MULTICENTRE STUDY CT-AVC thresholds were next examined in an international multicenter registry incorporating a wide range of patient populations, scanner vendors and analysis platforms. Eight centres contributed data from 918 patients (age 77±10, 60% male, Vmax 3.88±0.90 m/s) who had undergone ECG-gated CT within 3 months of echocardiography. Of these 708 (77%) had concordant echocardiographic assessments, in whom our own optimum sex-specific CT-AVC thresholds (women 1377, men 2062 AU) were nearly identical to those previously published. These thresholds provided excellent discrimination for severe stenosis (c-statistic: women 0.92, men 0.88) and independently predicted AVR and death after adjustment for age, sex, Vmax ≥4 m/s and AVA < 1 cm2 (hazards ratio, 3.02 [95% confidence intervals, 1.83-4.99], p < 0.001). In patients with discordant echocardiographic assessments (n=210), CT-AVC thresholds predicted an adverse prognosis. BICUSPID AORTIC VALVES Within the multicentre study, higher continuity-derived estimates of aortic valve area were observed in patients with bicuspid valves (n=68, 1.07±0.35 cm) compared to those with tri-leaflet valves (0.89±0.36 cm p < 0.001,). This was despite no differences in measurements of Vmax (p=0.152), or CT-AVC scores (p=0.313). The accuracy of AVA measurments in bicuspid valves was therefore tested against alternative markers of disease severity. AVA measurements in bicuspid valves demonstrated extremely weak associations with CT-AVC scores (r2=0.08, p=0.02) and failed to correlate with downstream markers of disease severity in the valve and myocardium and against clinical outcomes. AVA measurements in bicuspid patients also failed to independently predict AVR/death after adjustment for Vmax ≥4 m/s, age and gender. In this population CT-AVC thresholds (women 1377, men 2062 AU) again provided excellent discrimination for severe stenosis. CONCLUSIONS Optimised 18F-fluoride PET-CT scans quantify and localise calcification activity, consolidating its potential as a biomarker or end-point in clinical trials of novel therapies. CT calcium scoring of aortic valves is a reproducible technique, which provides diagnostic clarity in addition to powerful prediction of disease progression and adverse clinical events.
4

Experimental biomechanics of trinucleid fringe pits (Trilobita)

Pearson, Kirk 10 August 2017 (has links)
No description available.
5

Development of a New 3-D Coal Mass Strength Criterion

He, Pengfei January 2016 (has links)
In this research, a novel, unique systematic procedure was implemented to investigate the influence of the fracture networks and confining stresses on the jointed coal mass strength (JCMS). Both a laboratory experimental scheme and a numerical modeling scheme were carried out at the 3-D level. The laboratory experiments were performed to achieve the following three goals. Firstly, the geomechanical properties for the intact coal and coal discontinuities were estimated through the laboratory geomechanical property tests. Secondly, naturally existing fracture networks in the cubic coal blocks were first detected by the industrial Computed Tomography (CT) scanning technique and then quantified by the fracture tensor based methodology. Thirdly, polyaxial tests were conducted on the same cubic coal blocks to obtain the JCMS values under different confining stresses. With respect to the numerical modeling, PFC^3D and 3DEC software packages were used to simulate the polyaxial compression tests for intact and jointed cubic coal blocks, respectively. From more than twenty intact rock strength criteria, nine criteria were selected for this research. The intact coal strength data bank obtained from PFC^3D modeling was used to evaluate the applicability of nine different intact rock strength criteria. A modified grid search (MGS) procedure is proposed and used to find the best fitting parameter values and calculate the coefficient of determination (R²) values for each criterion. These criteria are compared in detail using the following features: R² values, σ₁ - σ₂ plots for different σ₃, shapes on the deviatoric planes, linearity or nonlinearity on the meridian planes. The regression analysis and the MGS procedure were found to be equivalent in finding the best fitting parameter values for a certain intact rock strength criterion. Through the comparisons, the modified Wiebols-Cook and modified Lade criteria were found to provide the highest R² values and fit the intact coal strength data best on the σ₁ - σ₂ coordinate plane and meridian planes. Based on the appearances on the deviatoric plane, the nine intact rock strength criteria are categorized into three types: the single shear stress criteria, the octahedral shear stress criteria and the criteria incorporating the maximum principal shear stress and partial intermediate principal shear stress. The relative positions of the different criteria on two specific meridian planes are also discussed. The geometric model of the jointed coal block was first set up by incorporating the fracture network constructed from the CT scanning into the intact coal block using a modified fictitious joint procedure. The numerical parameter values of intact coal and coal discontinuities were then calibrated and validated through a trial and error procedure using the laboratory test results of some selected samples. Next the JCMS data bank was consummated by performing a four-phase numerical investigation on several jointed coal blocks having selected fracture networks and five additional artificial fracture networks under different confining stress combinations. Finally, a new empirical coal mass strength criterion was developed to estimate the JCMS values at the 3-D level. The developed new model is capable of capturing the scale effect and anisotropic strength behaviors. It can also be applied to rock masses having approximately orthogonal fracture systems or for masses where fracture system can be reduced to an equivalent orthogonal fracture system.The following new contributions were made in this dissertation to advance the existing state-of-art on the dissertation topic: (a) A new, unique methodology as shown in Fig. 1.1 incorporating the following aspects was used to develop a new 3-D coal mass strength criterion: a complete set of geomechanical property tests, fracture network detection and quantification, polyaxial compression tests, numerical decomposition techniques; (b) A new procedure was developed to construct the fracture network in the coal cubes starting from CT scans to perform numerical modeling using 3DEC. In this procedure, a modified fictitious joint framework was also proposed to extend the applicability of the original fictitious joint framework, which allows incorporating a large quantity of non-persistent joints with acceptable numerical calculation effort; (c) A new 3-D coal mass strength criterion was developed to incorporate the fracture network and 3-D confining stress system to capture the anisotropy and scale effect of coal mass strength. The proposed criterion not only includes the influence of the intermediate principal stress, which is ignored by some existing strength criteria, but also includes the intensity and orientation and size probability distributions of the fracture system explicitly by a fracture tensor based methodology, which is far more advanced than most of the current criteria that are based on rock mass classification systems having only scalar indices; (d) A modified grid search procedure was proposed and used to evaluate the applicability of nine different intact rock strength criteria. The best intact rock strength criteria applicable for the intact coal data obtained through PFC^3D modeling were found by performing the most detailed intact rock strength criteria evaluation incorporating σ₁ - σ₂ - σ₃ plots and behaviors on the deviatoric and meridian planes, which improves the understanding of the available intact rock strength criteria.
6

Výpočtové modelování přenosu tepla v porézních strukturách / Computational modeling of heat transfer problems in porous structures

Mráz, Kryštof January 2020 (has links)
Vrstva okují, skládající se z oxidů železa, která se tvoří na povrchu oceli při jejím tepelném zpracování, má velký vliv na tepelné metalurgické procesy. Tepelná vodivost okují je jeden z klíčových parametrů pro numerické modelování procesů odkujování a chlazení oceli. Tato vodivost je nicméně silně ovlivňována porézní strukturou okují a žádná všeobecně uznávaná materiálová data nejsou v současnosti dostupná. Cílem této práce bylo provést stacionární tepelnou analýzu za účelem stanovení tepelné vodivosti vrstvy okují. Byl vytvořen podrobný 3D MKP model vrstvy okují založený na datech získaných pomocí CT skenování. Je popsáno získání CT obrazu a jeho zpracování. Využity byly dva různé způsoby segmentace. Pravidelná krychlová výpočetní síť byla vytvořena přímo z voxelové matice zpracovaného CT obrazu. Výsledné hodnoty tepelné vodivosti získané z provedené MKP analýzy byly téměř identické pro obě metody segmentace, což prokazuje jejich vhodnost. Výsledná tepelná vodivost okují může být dále využita jako materiálová charakteristika v numerických modelech tepelného zpracování oceli
7

Fetal Developmental Anatomy of the Human Cardiovascular and Central Nervous Systems Using Lugol&#x2019;s Iodine Staining and Micro-Computed Tomography

Spaw, Alexandra J. 02 May 2014 (has links)
No description available.
8

Water Resistance of Scots Pine Joints Produced by Linear Friction Welding / Résistance à l'eau du joint de soudure par friction linéaire du Pin Sylvestre

Vaziri, Mojgan 30 September 2011 (has links)
Le soudage du bois est une technique d'assemblage sans adhésif de deux pièces de bois, leur soudure étant produite par friction mécanique sous pression des deux pièces. Ce procédé, applicable à des pièces de bois plates, d'essences identiques ou différentes, se prête à la fabrication de meubles et à la menuiserie. Cependant, le joint obtenu n'est pas de classe "extérieur", ce qui le réserve à un usage "intérieur". En effet, un joint destiné à une utilisation extérieure ou en milieu à humidité variable doit présenter une résistance élevée à l'eau. L'objectif principal de cette thèse est d'étudier la résistance à l'eau du bois soudé. A cet effet, des méthodes d'essais complémentaires et non-destructrices ont été utilisées, comme le scanner ou l'imagerie par résonance magnétique (IRM). L'influence des paramètres de soudage et des propriétés du bois sur, d'une part, la formation et la propagation des fissures dans la ligne de soudure, et sur, d'autre part, la densité et l'absorption d'eau de la soudure a été ainsi étudiée. Les expériences de cette thèse seront menées sur des échantillons de pin (Pinus sylvestris) de dimensions 200 mm x20 mm x 40 mm, coupés dans la direction longitudinale du fil du bois. La Norme Européenne EN 205 a servi de cadre pour déterminer la résistance des échantillons de pin en traction-cisaillement. Les méthodes d'essais (non-destructrices) ont été utilisées selon leur pertinence: le scanner a servi à étudier la formation et la propagation des fissures; l'imagerie par résonance magnétique (IRM) a permis quant à elle de caractériser la pénétration et l'infiltration d'eau dans le bois soudé.Le mécanisme d'adhérence du pin a été étudié grâce à la RMN MAS (spectrométrie à résonance magnétique nucléaire avec polarisation croisée et rotation à l?angle magique) du carbone13 et à la micro-densitométrie par rayons X. Ces différentes méthodes, non destructrices, offrent l'avantage d'une analyse non invasive et l'élimination de facteurs parasites liés à la préparation et à la coupe du bois. Voici en résumé les résultats obtenus les plus marquants: (1) Le scanner et l'imagerie par résonance magnétique (IRM) sont des méthodes de recherche particulièrement polyvalentes et adaptées à l'étude des bois soudés. (2) L'utilisation de bois de coeur, une pression de soudage de 1.3 Mpa et un temps de soudage de 1.5 s permettent d'augmenter la résistance à l'eau du pin soudé. (3) Des tests d'optimisation ont montré que la résistance du pin en traction-cisaillement est plus sensible aux variations de temps de soudage qu'au temps de refroidissement et qu'elle peut être optimisée à plus de 9.7 MPa en respectant une pression de 1.3 Mpa, un temps de soudage > 3.5 s et un temps de refroidissement < 60 s. (4) La résistance à l'eau du bois soudé peut être améliorée dans une certaine mesure en faisant varier paramètres de soudage et propriétés des essences, mais dans tous les cas, le recours à un imperméabilisant naturel et écologique reste nécessaire. (5) Le pin soudé possède une résistance à l'eau et en traction-cisaillement inhabituellement élevée, cela pouvant s'expliquer par une teneur en composés extractifs augmentée. (6) Des essais sous IRM ont montré que les causes de rupture du joint varient suivant l'essence: faible résistance à l'eau de la ligne de soudure dans le cas du hêtre soudé, retrait et expansion du bois dans le cas du pin soudé. (7) Les extractifs du pin améliorent nettement la résistance à l'eau du joint soudé, mais à un niveau qui ne lui permet cependant pas la certification "extérieur" sans protection. En revanche, il peut être certifié "semi-extérieur" avec protection. / Wood welding is a mechanical friction process allowing the assembly of timber without any adhesives. The process consists of applying mechanical friction, under pressure, alternately to the two wood surfaces to be welded. This process can be applied to weld two flat pieces of timber, originating from the same or different tree species, and can be used in the manufacture of furniture and wood joinery. The only limitation is that the joint is not exterior-grade, but only suitable for interior joints. Exterior use, or use in an environment with varying humidity demands water resistance of the welded joints. The main objective of this thesis is to study the water resistance of the welded wood. This is complemented with special attention to non-destructive test methods such as X-ray Computed Tomography (CT-) scanning and Magnetic Resolution Imaging (MRI). The influence of welding parameters and wood properties on crack formation and crack propagation in the weldline was investigated. The influence of these parameters on weldline density and water absorption in the weldline were also studied. Investigations in this thesis are based on welded samples of Scots pine (Pinus sylvestris) of the dimensions 200 mm × 20 mm × 40 mm which were cut in the longitudinal direction of the wood grain. The tensile-shear strength of the welded Scots pine samples were determined using European standard EN 205. Different non-destructive methods such as X-ray Computed Tomography (CT-) scanning to study crack formation and propagation, and magnetic Resolution Imaging (MRI) to characterize water penetration and the distribution mechanism in welded wood were used. Solid state CPMAS 13C NMR spectrometry and X-ray microdensitometry investigations were carried out to study the mechanism of adhesion in Scots pine. These various non-destructive methods offer the advantage of non-invasive analysis and the elimination of any artifacts present due to preparation and sectioning. The most important results are summarized as follows: (1) X-ray Computed Tomography (CT-) scanning and Magnetic Resolution Imaging (MRI) are versatile research methods applicable to investigations of welded woods. (2) Water resistance of welded Scots pine can be increased using heartwood, a welding pressure of 1.3 MPa, and a welding time of 1.5 s. (3) Optimization tests showed that the tensile-shear strength of Scots pine was more sensitive to welding time changes than holding time and could be optimized to more than 9.7 MPa using 1.3 MPa welding pressure, > 3.5 s welding time, and < 60 s holding time. (4) Changing welding parameters and wood properties can increase water resistance of welded wood to some extent, but treating the weldline with certain natural and environmentally-friendly water repellents is still necessary. (5) Welded Scots pine shows unusually high water resistance and tensile-shear strength. This may be explained by there being more extractives compounds in Scots pine. (6) MRI experiments showed that the origin of the joint failure in welded beech is poor water resistance of the weldline, while swelling and shrinkage of wood are the main reasons for joint failure of welded Scots pine. (7) Extractives in Scots pine dramatically improve water resistance of the welded joint, but not to a level to classify the joint as an unprotected exterior grade. However, it can qualify as a joint for protected semi-exterior application.
9

Phase-Contrast Imaging, Towards G2-less Grating Interferometry With Deep Silicon / Faskontrastavbildning, Mot G2-lös Gitterinterferometri med Djupt Kisel

Brunskog, Rickard January 2022 (has links)
Conventional phase-contrast imaging entails stepping an analyser grating across the detector to resolve the interference pattern caused by the x-rays after passing through a series of gratings in a so-called Talbot-Lau interferometer. However, the analyser grating in the interferometer poses a challenge, not only due to the machinery and alignment required but also due to each exposure delivering a dose to the subject. Another downside of the analyser grating is that whilst the phase-step length can be adjusted, the x-rays allowed through the grating depend on its slit-width ratio, which cannot be changed without changing the whole grating.This thesis evaluates if the analyser grating can be removed by instead using a deep silicon photon-counting detector which can determine the photon interaction position with an uncertainty of around one micrometre. It is concluded that such a high-resolution detector will not only be able to remove the need for an analyser grating and its associated challenges, but the results also imply a three-fold increase in the contrast-to-noise ratio when dose-matching the grating-based approach with the grating-less approach. Furthermore, the conventional absorption image, which is lost when using an analyser grating, will still be available using a high-resolution detector. Finally, the removal of the analyser grating shifts most of the system conditions to the source grating and the phase grating, making it possible to design a compact unit of the two gratings for integration into a CT scanner. / Konventionell faskontrast involverar att stega ett analysgitter över detektorn för att detektera interferensmönstret som skapas av röntgenstrålarna efter att de passerat genom en serie gitter i en så kallad Talbot-Lau interferometer. Analysgittret introducerar en utmaning, inte enbart på grund av maskineriet och kalibreringen som krävs, utan även då varje steg utsätter det röntgade föremålet för strålning. Ytterligare en begränsning är att även om längden på stegen kan justeras beror mängden röntgenstrålar som passerar genom analysgittret på gittrets slitsbredd, vilken inte går att ändra på utan att byta hela gittret.Den här uppsatsen utvärderar om analysgittret kan tas bort genom att istället använda en högupplöst fotonräknande djup kiseldetektor som har förmågan att uppskatta positionen av en fotoninteraktion inom en mikrometer. Slutsatsen är att en sådan detektor kommer att kunna ersätta analysgittret och resultaten tyder på en trefaldig ökning av contrast-to-noise ratio vid dosmatchning mellan metoden med analysgitter och metoden med en högupplöst detektor. Vidare behålls den konventionella absorptionsbilden då man använder en högupplöst detektor, någonting som annars går förlorat vid användandet av analysgittret. Slutligen skiftas de flesta villkoren på systemet till källgittret och fasgittret, vilket tyder på att en kompakt konstruktion av dessa två gitter skulle kunna integreras i en CT-skanner.

Page generated in 0.082 seconds