• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 5
  • 4
  • 2
  • Tagged with
  • 18
  • 10
  • 7
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Physikalische Charakterisierung von Calciumphosphat-Pulvern zur Einstellung von Prozessparametern für die Herstellung von Knochenzement / Physical characterisation of calcium phosphate powders for the adjustment of processing parameters for the fabrication of bone cement

Hofmann, Michael Peter January 2003 (has links) (PDF)
Die Arbeit behandelt die physikalische Charakterisierung der Herstellung einer Tetracalciumphosphat (TTCP) / Calciumhydrogenphosphat (DCPA) Pulvermischung zur Anwendung als Knochenzement. Ziel war die Gewinnung einer Korrelation von Prozessparametern mit anwendungsrelevanten Zementeigenschaften, also hohe mechanische Festigkeit, definierte Abbindezeit, physiologischer pH-Wert-Verlauf und Reproduzierbarkeit. Die Einstellung eines physiologischen pH-Werts im Bereich 7-8 der Zementpaste erfordert eine geeignete Lösungsrate beider Pulverkomponenten. Dies gelingt durch Mahlung mit einer Einstellung der mittleren Partikelgröße von 10-20 µm (TTCP) und 0,5-2 µm (DCPA). DCPA wird nass gemahlen; das Suspensionsmedium dient der Agglomerationsverminderung, da bei Partikelgrößen von 0,5-2 µm interpartikuläre Kräfte gegenüber der Gewichtskraft dominieren. TTCP wurde durch Sinterung von DCPA und Calciumcarbonat bei 1500°C hergestellt und trocken vermahlen. Die Ermittlung der mittleren Partikelgrößen und relativen Breite der Partikelgrößenverteilungen, der sogenannten Spanne, nach Mahlung erfolgte durch Laserstreuung und Auswertung der Streumuster nach der Mie-Theorie. Mahlungen von TTCP führen zu Feinkornanteilen mit Partikelgrößen < 1 µm, die eine gleichmäßige Lösungsrate zu Beginn der Abbindereaktion verhindern. Durch Variation der Mahlparameter kann dieser Feinkornanteil minimiert werden. Dennoch besteht die Notwendigkeit, Abbinde-Beschleuniger auf Natriumphosphat (NaP)-Basis zu verwenden, um die erhöhte Lösungsrate der TTCP-Komponente zu kompensieren. Kriterium für die Auswahl des geeigneten Suspensionsmediums für die Nassmahlung von DCPA ist das Zetapotential von DCPA-Partikeln in flüssiger Phase, welches durch Laser-Doppler-Elektrophorese gemessen wird. Die Messungen zeigen, dass sich das Zetapotential mit Partikelgröße und Spanne korrelieren lässt. Hohe Zetapotential-Werte zu Beginn der Mahlung führen zu kleiner Endpartikelgröße. Das Zetapotential von gemahlenen DCPA-Pulvern steigt bei der Mahlung an und bestimmt die minimale Spanne. Partikelgröße und Spanne bestimmen über die effektive Viskosität außerdem das Ende des Mahlvorgangs. Als Suspensionsmedium zur Einstellung kleiner Partikelgröße bei gleichzeitig geringer Spanne eignet sich Reinstwasser, gefolgt von Ethylenglykol und Ethanol. Es lassen sich mittlere Partikelgrößen von 0,6 µm bei einer Spanne von 1,0 realisieren. Die Mahlung setzt neben der Partikelgröße die Kristallinität von DCPA und TTCP herab, durch eine mechanisch induzierte Phasenumwandlung in den amorphen Zustand. Röntgendiffraktometrische Untersuchungen, XRD, der Pulver zeigen eine Abnahme der Intensität der Beugungsreflexe um ca. 50% für TTCP und ca. 30% für DCPA nach 24h. Die Auswertung der Beugungsspektren durch Rietveld-Analyse ergibt gleichzeitig eine kontinuierliche Abnahme der mittleren Kristallitgröße. Die Bildung amorpher Anteile resultiert für TTCP in abbindefähigen, einkomponentigen Zementen, die im stark basischen Bereich mit 2.5%iger Na2HPO4-Lösung Hydroxylapatit und Calciumhydroxid bilden. Hochkristallines TTCP ist dagegen nicht reaktiv, bedingt durch die Ausbildung einer Hydroxylapatitschicht um die Partikel. Suspensionsmedium und Luftfeuchtigkeit bewirken eine Kontamination der feinkörnigen Pulver. Stickstoffadsorptions-Messungen, BET, zeigen die Lokalisation des Kontaminats auf der kompakten, nicht porösen Partikeloberfläche. Der Anteil an nicht entfernbarem Suspensionsmedium, bestimmt durch Thermogravimetrie, liegt bei 3-5% nach Trocknung an Luft und lässt sich auf < 1% bei Vakuumtrocknung reduzieren. Während organische wasserlösliche Kontaminationen keinen Einfluss auf die Lösungsrate und Reaktivität von DCPA ergeben, führt Wasser als Suspensionsmedium bzw. das Einwirken von Luftfeuchtigkeit auf die getrockneten Pulver zu einer starken Herabsetzung der Reaktivität. Ursache ist die Ausbildung einer diffusionshemmenden Hydroxylapatit-Schicht um die Partikel durch Hydrolyse der Calciumphosphate. DCPA, durch Mahlung in Wasser inaktivierend kontaminiert, zeigt die niedrigste Lösungsrate, trotz großer spezifischer Oberfläche. Die Mischung der Pulver erfolgt durch Selbstmischung bei geringer mechanischer Krafteinleitung; die hochdispersen DCPA-Partikel agglomerieren aufgrund interpartikulärer van-der-Waals-Kräfte an den großen TTCP-Partikeln. Ausgehärtete Zemente zeigen eine Korrelation zwischen der Druckfestigkeit und der Partikelgröße, sowie eine Korrelation von Zugfestigkeit und Spanne der Partikelgrößenverteilung von DCPA. Ein erhöhter Feinkornanteil des TTCP-Pulvers führt zur Reduktion der mechanischen Festigkeit. Die vorgestellte physikalische Charakterisierung der TTCP/DCPA- Pulverherstellung führt zu einem Medizinprodukt mit Druckfestigkeiten von 75 MPa und Zugfestigkeiten von 12 MPa. Abbindezeit und pH-Wert-Verlauf bei der Aushärtung lassen sich durch die Konzentration von NaP-Abbindebeschleunigern einstellen. / This thesis is about the physical characterisation of the fabrication process of a Tetracalciumphophate (TTCP) / Calciumhydrogenphosphate (DCPA) bone cement powder mixture. The goal was to achieve a correlation between processing parameters and application relevant properties of the cement matrix, i.e. high mechanical strength, defined setting time, physiological pH-value and reproducibility. For the adjustment of a physiological pH-value between 7 and 8 of the cement paste it is necessary to adjust the solubility rate of both powder components. This is done by adjusting the medium particle size of TTCP and DCPA to 10-20 µm respectively 0,5-2 µm. DCPA is wet milled; the suspension medium has to prevent agglomeration, because at particle sizes between 0,5-2 µm attractive interparticular forces dominate over the deagglomerating weight of the powder particles. TTCP is fabricated by sintering a DCPA / Calciumcarbonate mixture at 1500°C and dry milling it. The measurement of medium particle size and the relative width of the particle size distribution, the so called span, after milling were done by laser diffraction and calculation following Mie-theory. The milling of TTCP leads to a fine powder fraction with particle sizes below 1 µm, which prevents a uniform solubility rate at the beginning of the setting reaction. This fine powder fraction can be minimized by variation of the milling parameters. Nonetheless it is necessary to use sodium phosphate setting-accelerators to equalise the higher solubility rate of the TTCP-cements component. Criteria for choosing the suspension medium for the wet milling of DCPA is the zeta potential of DCPA particles in liquid phase, measured by Laser Doppler Electrophoresis (LDE). The measurements indicate that the zeta potential is correlated with particle size and span. A high zeta potential value at the start of the milling process leads to a small final particle size. The zeta potential of milled DCPA rises with the milling process and defines the minimum span. Particle size and span determine the effective viscosity and therefore the end of the milling process. For achieving a small particle size together with a small span distilled water is most suitable, followed by ethylene glycol and ethyl alcohol. A medium particle size of 0,6 µm together with a span of 1,0 can be realised. The milling process is also reducing the cristallinity of DCPA and TTCP by a mechanically induced phase change to the amorphous state. X-Ray diffraction measurements of the powders after 24h of milling show an intensity decrease of the diffraction patterns by almost 50% for TTCP and almost 30% for DCPA. The analyses of the diffraction patterns by Rietveld-analysis show a continuous decrease of the medium crystallite size at the same time. The formation of amorphous TTCP fractions results in a one component cement able to set in a high pH-regime. High cristallinity TTCP is not reactive due to the hydroxyapatite layer on the particle surface. The suspension medium and humidity are causing a contamination of the powder particles. Nitrogenadsorption measurements, BET, are showing that the contaminant is located on the compact non-porous particle surface. The fraction of not extractable suspension medium, determined by thermogravimetry, is in the region of 3-5% after drying in air and can be reduced to less than 1% by drying in vacuum. Organic watersoluble contamination does not lead to changes in solubility rate or reactivity of DCPA particles. Water as suspension medium or humidity reduces the reactivity significantly. The reason is a hydroxyapatite layer on the DCPA particles caused by hydrolysis of the calciumphosphate leading to decreased diffusion. Water milled DCPA is showing the lowest solubility rate despite having the highest specific surface area. The two powder components are literally self mixing. The disperse DCPA particles are agglomerating on the surface of the larger TTCP particles due to attractive van-der-Waals-forces. The hardened cement matrix is showing a correlation between compressive strength and particle size and between diametral tensile strength and the span of the particle size distribution. An increase of the fine powder fraction of TTCP leads to a decrease in mechanical strength. The physical characterisation of the fabrication process of a TTCP/DCPA-cement powder mixture leads to a medical device with a compressive strength of 75 MPa and a diametral tensile strength of 12 MPa. Setting time and pH-value can be adjusted by the amount of sodium phosphate setting-accelerator.
12

Rapid-Prototyping hydraulisch härtender Calcium- und Magnesiumphosphatzemente mit lokaler Wirkstoffmodifikation / Rapid-prototyping of hydraulic calcium- and magnesium phosphate cements with local drug modification

Vorndran, Elke January 2011 (has links) (PDF)
Ziel dieser Arbeit war die Herstellung individuell formbarer Strukturen mittels des 3D-Pulverdrucks auf Basis von bei Raumtemperatur hydraulisch abbindenden Knochenzementpulvern. Neben der Entwicklung neuartiger Zementformulierungen auf Basis von Magnesiumphosphaten war vor allem die gleichzeitige Ausstattung der Werkstoffe mit temperaturlabilen und bioaktiven Verbindungen ein wichtiger Entwicklungsschritt. Die Lokalisation der Wirkstoffe korreliert dabei mit entsprechenden Farbinformationen im Design der Konstrukte, die durch einen Mehrfarbendrucker physikalisch abgebildet werden. Das auf Calciumphosphat basierende System hat den Nachteil, dass die Abbindereaktion bei stark sauren pH-Werten abläuft, was negative Auswirkungen auf die gleichzeitige Ausstattung mit sensitiven Wirkstoffen hat. Zur Lösung dieser Problematik wurde ein neues Knochenzementpulver auf Magnesiumphosphatbasis entwickelt, welches unter neutralen pH-Bedingungen mit ammoniumhaltigem Binder zu dem Mineral Struvit abbindet. Das Zementpulver aus Trimagnesiumphosphat wurde bezüglich der pulvertechnologischen Eigenschaften, wie Partikelgröße, Partikelgrößenverteilung, Glättungseigenschaften und Schüttdichte sowie hinsichtlich des Abbindeverhaltens charakterisiert und für den Druckprozess optimiert. Die hohe Strukturgenauigkeit ermöglichte die Darstellung von makroporösen Strukturen mit einem minimalen Porendurchmesser von ca. 200 µm. Gute mechanische Kennwerte der gedruckten Strukturen, sowie eine hohe Umsetzungsrate zur gewünschten Phase Struvit wurden durch eine Nachhärtung in Ammoniumphosphatlösung erhalten. Die Druckfestigkeit betrug > 20 MPa und der Phasenanteil von Struvit konnte auf insgesamt 54 % gesteigert werden. Die Darstellung von wirkstoffmodifizierten Calciumphosphat- und Magnesiumphosphatstrukturen durch Verwendung eines Mehrfarbendruckers wurde beginnend vom Design der Strukturen bis hin zur experimentellen Bestimmung der Korrelation von Farbinformation und Binderapplikation etabliert. Zur Sicherstellung einer hohen Druckqualität und der Ortsständigkeit gedruckter Wirkstoffe erwies sich eine zusätzliche Modifikation des Tricalciumphosphatpulvers mit quellfähigen Polymeren (Hydroxypropylmethyl-cellulose (HPMC) bzw. Chitosan) als erfolgreich. Eine maximale Auflösung von ca. 400 µm konnte für eine HPMC/Chitosan/Calciumphosphat-Variante erreicht werden, während das hochreaktive Magnesiumphosphat/Magnesiumoxid-System eine Auflösung von 480 µm aufwies. Die Ortsständigkeit eingebrachter Lösungen war Voraussetzung für die Steuerung der Freisetzungskinetik. Das Freisetzungsverhalten in vitro wurde in Abhängigkeit von der Wirkstofflokalisation (homogen, Depot, Gradient) innerhalb der Matrix und unter Einbringung zusätzlicher polymerer Diffusionsbarrieren für den Wirkstoff Vancomycin untersucht. Dabei zeigte sich, dass die Modifikation der Matrices mit Polymeren zu einer verzögerten Freisetzung führte. Die lokale Wirkstoffmodifikation der Matrices in Form eines Depots oder Gradienten hatte Einfluss auf die Freisetzungskinetik, wobei eine lineare Freisetzung mit der Zeit (Kinetik 0. Ordnung) erreicht werden konnte. Die applizierten Wirkstoffe umfassten sowohl niedermolekulare Verbindungen, wie etwa das Antibiotikum Vancomycin oder das Polysaccharid Heparin, als auch proteinbasierte Faktoren wie den Knochenwachstumsfaktor rhBMP-2. Beurteilt wurde die pharmakologische Wirksamkeit der Verbindungen nach dem Druck, sowie nach der Freisetzung aus einer Calciumphosphatmatrix für den Wirkstoff Vancomycin. Es konnte belegt werden, dass die biologische Aktivität nach dem Druckprozess zu über 80 % erhalten blieb. Limitierend war der stark saure pH-Wert bei bruschitbasierten Systemen, der zu einer Inaktivierung des Proteins führte. Diesem Problem könnte durch die Nutzung des neutral abbindenden Magnesiumphosphatsystems entgegengewirkt werden. Abschließend erfolgten eine mikrostrukturelle Charakterisierung der Calciumphosphat- und Magnesiumphosphatmatrices mittels µ-CT-Analyse und Heliumpyknometrie, sowie eine quantitative Phasenanalyse nach Rietveld. Experimentell konnte nachgewiesen werden, dass mit Hilfe des 3D-Pulverdruck die Darstellung von Makroporen > 200 µm möglich ist. Die Analyse der Phasenzusammensetzung ergab, dass die Umsetzungsrate von Tricalciumphosphat und Trimagnesiumphosphat zu den gewünschten Phasen Bruschit und Struvit infolge des Nachhärtungsprozesses signifikant gesteigert werden konnte. Im Zuge dessen nahm die Porosität der gedruckten Matrices der Phase Struvit von 58 % auf 26 % und der Phase Bruschit von 47 % auf 38 % ab. / Aim of this study was the room temperature fabrication of individually formed structures via 3D-powder printing based on hydraulic bone cements. In addition to the development of a novel cement formulation composed of magnesium phosphate, the simultaneous modification of matrices during the printing process with temperature sensitive and bioactive drugs was an important part of the work. The drug localization within the matrices is hereby correlated with an analogous colour design of the structures, which is physically reproduced by the multi-colour-printer. The calcium phosphate based system has the disadvantage of a strongly acidic setting reaction, which has negative effects on the simultaneous modification with sensitive bioactive agents. To solve this problem a novel bone cement formulation based on magnesium phosphate was established. This cement reacts with ammonium based binder solution within seconds to form the mineral struvite at neutral pH. The technological properties of the of trimagnesium phosphate cement powder, including particle size, particle size distribution, spreadability, powder density, and the setting behaviour, were characterized and optimized for the printing process. The high structural accuracy enabled the production of macroporous structures with a minimal pore diameter of approximately 200 µm. Proper mechanical characteristics of the printed structures as well as a high degree of conversion to the struvite phase were achieved by post-hardening in ammonium phosphate solution. The compressive strength could be increased to more than 20 MPa and the phase fraction of struvite could be increased to a maximum value of a total of 54 %. The fabrication of drug loaded calcium phosphate and magnesium phosphate scaffolds using a multi-colour-printer was established, beginning with the structure design and following the experimental verification of the correlation between the colour information and the applied binder. To guarantee a high accuracy of printing and the localization of the printed drugs, a supplemental modification of the tricalcium phosphate powder with swellable polymers (hydroxypropylmethylcellulose (HPMC) or chitosan) was successful. A maximum resolution of about 400 µm was achieved by an HPMC/chitosan/calcium phosphate composition, whereas the highly reactive magnesium phosphate/magnesium oxide system showed a resolution of about 480 µm. The localization of the applied solutions was a prerequisite to control the release kinetics of the drugs. The release kinetic of vancomycin was investigated in vitro depending on the drug localization (homogeneous, depot, gradient-like) within the matrix and by adding additional polymeric diffusion barriers. It could be shown that the polymeric modification of the matrices resulted in a delayed drug release. By discrete and depot-like or graded drug distributions within the matrices the release kinetic could be controlled, achieving a linear release with time (zero order release). The administered agents involved both low molecular compounds like the antibiotic vancomycin or the polysaccharide heparin and protein based factors like bone morphogenic factor rhBMP-2. Evaluation of pharmacological activity of the agents after printing as well as after release of vancomycin from a calcium phosphate matrix was determined, indicating that the bulk biological activity of more than 80 % was retained during the printing process. The limiting factor of the brushite based system was the strong acidic pH, which resulted in an inactivation of protein-based bioactives. This problem may be solved by using neutrally setting magnesium phosphate systems. Finally a microstructural characterization of calcium phosphate and magnesium phosphate matrices by µ-CT analysis and helium pycnometry as well as a quantitative phase analysis by Rietveld was performed. It was demonstrated, that 3D-printing allows the manufacturing of macro pores > 200 µm. The analysis of phase composition showed a significant increase of the degree of conversion from tricalcium phosphate or trimagnesium phosphate to the phases brushite or struvite due to the post hardening process. Hence the porosity of the printed matrices decreased from 58 % to 26 % for struvite and from 47 % to 38 % for brushite.
13

Processing of calcium and magnesium phosphate cements for bone substitution / Verarbeitung von Calcium- und Magnesiumphosphatzementen als Knochenersatz

Meininger [geb. Christ], Susanne January 2018 (has links) (PDF)
The main focus of this thesis was the processing of different calcium and magnesium phosphate cements together with an optimization of mechanical and biological properties. Therefore, different manufacturing techniques like 3D powder printing and centrifugally casting were employed for the fabrication of reinforced or biomedically improved implants. One of the main problems during 3D powder printing is the low green strength of many materials, especially when they are only physically bonded and do not undergo a setting reaction. Such materials need post-treatments like sintering to exhibit their full mechanical performance. However, the green bodies have to be removed from the printer requiring a certain stability. With the help of fiber reinforcement, the green strength of printed gypsum samples could be increased by the addition of polymeric and glass fibers within the printing process. The results showed that fiber reinforcement during 3D powder printing is possible and opens up diverse opportunities to enhance the damage tolerance of green bodies as well as directly printed samples. The transfer to biomedically relevant materials like calcium and magnesium phosphate cements and biocompatible fibers would be the next step towards reinforced patient-specific implants. In a second approach, centrifugally casting derived from construction industries was established for the fabrication of hollow bioceramic cylinders. The aim was the replacement of the diaphysis of long bones, which exhibit a tubular structure with a high density of cortical bone on the fringe. By centrifugation, cement slurries with and without additives could be fabricated to tubes. As a first establishment, the processing parameters regarding the material (e.g. cement composition) as well as the set-up (e.g. rotation times) had to be optimized for each system. In respect of mechanics, such tubes can keep up with 3D powder printed tubes, although the mechanical performance of 3D printed tubes is strongly dependent on printing directions. Additionally, some material compositions like dual setting systems cannot be fabricated by 3D powder printing. Therefore, a transfer of such techniques to centrifugally casting enabled the fabrication of tubular structures with an extremely high damage tolerance due to high deformation ability. A similar effect was achieved by fiber (mesh) addition, as already shown for 3D powder printing. Another possibility of centrifugally casting is the combination of different materials resulting in graded structures to adjust implant degradation or bone formation. This became especially apparent for the incorporation of the antibiotic vancomycin, which is used for the treatment of bacterial implant infections. A long-term release could be achieved by the entrapment of the drug between magnesium phosphate cement layers. Therefore, the release of the drug could be regulated by the degradation of the outer shell, which supports the release into an acidic bacterial environment. The centrifugally casting technique exhibited to be a versatile tool for numerous materials and applications including the fabrication of non-centrosymmetric patient-specific implants for the reconstruction of human long bones. The third project aimed to manufacture strontium-substituted magnesium phosphate implants with improved biological behavior by 3D powder printing. As the promoting effect of strontium on bone formation and the inhibitory impact on bone resorption is already well investigated, the incorporation of strontium into a degradable magnesium phosphate cement promised a fast integration and replacement of the implant. Porous structures were obtained with a high pore interconnectivity that is favorable for cell invasion and bone ingrowth. Despite the porosity, the mechanical performance was comparable to pure magnesium phosphate cement with a high reliability of the printed samples as quantitatively determined by Weibull statistics. However, the biological testing was impeded by the high degradation rate and the relating ion release. The high release of phosphate ions into surrounding media and the detachment of cement particles from the surface inhibited osteoblast growth and activity. To distinguish those two effects, a direct and indirect cell seeding is always required for degradable materials. Furthermore, the high phosphate release compared to the strontium release has to be managed during degradation such that the adverse effect of phosphate ions does not overwhelm the bone promoting effect of the strontium ions. The manufacturing techniques presented in this thesis together with the material property improvement offer a diverse tool box for the fabrication of patient-specific implants. This includes not just the individual implant shape but also the application like bone growth promotion, damage tolerance and local drug delivery. Therefore, this can act as the basis for further research on specific medical indications. / Der Fokus dieser Dissertation lag auf der Verarbeitung von Calcium- und Magnesiumphosphatzementen zusammen mit der Optimierung mechanischer und biologischer Eigenschaften. Dazu wurden verschiedene Produktionsverfahren wie beispielsweise der 3D Pulverdruck und der Schleuderguss verwendet, um mechanisch verstärkte oder biomedizinisch verbesserte Implantate herzustellen. Eines der Hauptprobleme des 3D Pulverdrucks ist die geringe Festigkeit des Grünkörpers vieler Materialien, besonders wenn diese lediglich physikalisch gebunden sind und keine Abbindereaktion durchlaufen. Solche Materialien müssen nachbearbeitet werden, beispielsweise durch Sintern, um ihre volle mechanische Leistungsfähigkeit zu entfalten. Die Grünkörper müssen jedoch aus dem 3D Drucker entnommen werden können, was eine gewisse Stabilität erfordert. Mit Hilfe der Faserverstärkung konnte die Festigkeit von gedruckten Grünkörper aus Gips erhöht werden, indem Polymer- und Glasfasern innerhalb des Druckprozesses eingebracht wurden. Die Ergebnisse zeigten, dass Faserverstärkung innerhalb des 3D Pulverdrucks möglich ist und dabei vielfältige Möglichkeiten eröffnet, um die Schadenstoleranz von Grünkörpern wie auch von direkt gedruckten Proben zu verbessern. Der nächste Schritt hin zu verstärkten, patientenspezifischen Implantaten wäre die Übertragung auf biomedizinisch relevante Materialien wie Calcium- und Magnesiumphosphatzemente und biokompatible Fasern. In einem zweiten Ansatz wurde der aus dem Baugewerbe stammende Schleuderguss für die Herstellung hohler Zylinder aus Biokeramik etabliert. Das Ziel war es, die Diaphyse von Röhrenknochen zu ersetzen, die eine tubuläre Struktur mit einer hohen Dichte an kortikalem Knochen am Rand aufweist. Durch Zentrifugieren konnten Zementpasten mit und ohne Additive zu Röhren verarbeitet werden. Zunächst mussten dabei die Prozessparameter bezüglich Material (z.B. Zementzusammensetzung) ebenso wie bezüglich der Einstellungen (z.B. Rotationszeiten) für jedes System optimiert werden. Im Hinblick auf ihre mechanischen Eigenschaften können solche Röhren mit 3D pulvergedruckten Röhren mithalten, obwohl die mechanische Leistungsfähigkeit von 3D gedruckten Röhren stark von der Druckrichtung abhängt. Zusätzlich können einige Materialkombinationen wie dual-abbindende Systeme nicht mit 3D Pulverdruck verarbeitet werden. Daher ermöglicht eine Übertragung solcher Techniken auf den Schleuderguss die Fertigung tubulärer Strukturen mit extrem hoher Schadenstoleranz aufgrund hoher Verformbarkeit. Wie bereits für das 3D Pulverdrucken gezeigt, konnte ein ähnlicher Effekt durch die Zugabe von Fasern (Geweben) erzielt werden. Eine weitere Möglichkeit des Schleudergusses ist die Kombination verschiedener Materialien zu gradientenartigen Strukturen, um den Implantatabbau oder die Knochenbildung anzupassen. Dies war besonders wichtig für die Einbringung des Antibiotikums Vancomycin, das für die Behandlung bakterieller Implantatinfektionen eingesetzt wird. Eine Langzeitfreisetzung konnte durch den Einbau des Arzneistoffs zwischen Magnesiumphosphatschichten erreicht werden. Dadurch konnte die Freisetzung des Wirkstoffs durch den Abbau der äußeren Hülle geregelt werden, was die Freisetzung in das saure Milieu von Bakterien unterstützt. Der Schleuderguss erwies sich als vielseitiges Werkzeug für viele Materialien und Anwendungen, was die Herstellung von nicht-zentrosymmetrischen, patientenspezifischen Implantaten zur Rekonstruktion von menschlichem Röhrenknochen einschließt. Das dritte Projekt zielte auf die Herstellung Strontium-substituierter Magnesiumphosphatimplantaten mittels 3D Pulverdruck mit verbessertem biologischen Verhalten ab. Da die unterstützende Wirkung von Strontium auf die Knochenbildung und die Hemmung des Knochenabbaus bereits eingehend untersucht sind, versprach die Einbringung von Strontium in den abbaubaren Magnesiumphosphatzement eine schnelle Integration und Ersatz des Implantats. Es konnten poröse Strukturen mit einer hohen Poreninterkonnektivität erhalten werden, was förderlich für die Einwanderung von Zellen und das Einwachsen von Knochen ist. Neben der Porosität waren auch die mechanischen Eigenschaften vergleichbar mit reinem Magnesiumphosphatzement mit einer hohen Verlässlichkeit der gedruckten Proben, was quantitativ durch eine Weibullstatistik bestimmt wurde. Die biologische Testung wurde allerdings durch die hohe Degradationsrate und der damit einhergehenden Ionenfreisetzung erschwert. Die hohe Freisetzung von Phosphationen in das umgebende Medium und die Ablösung von Zementpartikeln von der Oberfläche verhinderten das Wachstum und Aktivität der Osteoblasten. Um diese beiden Effekte voneinander unterscheiden zu können, war eine direkte und indirekte Zellbesiedelung der abbaubaren Materialien notwendig. Des Weiteren muss die hohe Phosphatfreisetzung im Vergleich zur Strontiumfreisetzung während des Abbaus derart gesteuert werden, dass die negativen Effekte der Phosphationen nicht die Förderung des Knochenaufbaus durch Strontiumionen überwiegen. Die in dieser Dissertation dargestellten Fertigungstechniken zusammen mit der Verbesserung der Materialeigenschaften bieten eine vielfältige Palette zur Herstellung patientenspezifischer Implantate. Dies beinhaltet nicht nur eine individuelle Implantatgeometrie, sondern auch eine Verbesserung der Schadenstoleranz, die Förderung des Knochenwachstums sowie eine lokale Wirkstofffreisetzung. Daher kann diese Arbeit als Grundlage für weitere Forschung im Bereich spezifischer, medizinischer Indikationen dienen.
14

Mechanische und rheologische Eigenschaften von Calciumphosphat-Zementen / Mechanical and rheological properties of calcium phosphate cements

Spatz, Kerstin January 2013 (has links) (PDF)
Zur Erhöhung der mechanischen Stabilität mineralischer Knochenzemente aus Calciumorthophosphaten (CPC) wurde in einem TTCP/DCPA-System das Zementedukt TTCP mit verschiedenen biokompatiblen Oxiden (SiO2, TiO2, ZrO2) während des Herstellungsprozesses dotiert. Dies führte zur Bildung von Calciummetallaten und einer Herabsetzung der Löslichkeit der TTCP-Komponente des Zements. Gegenüber einem oxidfreien Zement konnte die Druckfestigkeit von 65 MPa auf 80 MPa (SiO2) bzw. 100 MPa (TiO2) gesteigert werden. In einem zweiten Ansatz zur Verbesserung der Injizierbarkeit wurden die Wechselwirkungen der Partikeloberflächen mit der flüssigen Zementphase betrachtet. Durch biokompatible Additive sollte eine repulsive elektrostatische Wechselwirkung eingestellt werden, um Partikelagglomerate effektiv zu dispergieren und eine verflüssigende Wirkung zu erreichen. Die Injizierbarkeit eines TTCP/DCPA-Zements durch eine Kanüle mit 800 µm Durchmesser konnte durch die Verwendung von 500 mM tri-Natriumzitrat-Lösung aufgrund einer deutlichen Herabsetzung der Viskosität der Zementpaste signifikant gesteigert werden (>95%, P/L 3,3/1, Kraftaufwand 20 N). Abschließend wurde der Einfluss der Partikelgrößenverteilung auf die Festigkeit und Injizierbarkeit einer auf monomodaler Partikelgrößenverteilung basierten Zementmatrix untersucht. Hierzu wurden einem mechanisch aktivierten a-TCP-System unreaktive, feinkörnige Füllstoffpopulationen (TiO2, CaHPO4, CaCO3) zugesetzt und systematisch deren Effekt in Verbindung mit einer Partikelaufladung durch tri-Natriumzitrat auf die rheologischen und mechanischen Eigenschaften untersucht. Erst die Kombination einer bimodalen Partikelgrößenverteilung mit tri-Natriumzitrat-Lösung führte zu einer starken Erniedrigung der Viskosität, damit zur nahezu vollständigen Injizierbarkeit der Zemente und einer teilweise signifikanten Steigerung der mechanischen Festigkeiten (z.B. 72 MPa reiner a-TCP-Zement auf 142 MPa mit Zusatz von CaHPO4). / An improvement of the mechanical strength of calcium phosphate bone cements in combination with a lower cement paste viscosity for better injectability was investigated. A first approach to improve the mechanical stability consisted in adding several biocompatible oxides (SiO2, TiO2, ZrO2) during the fabrication process of tetracalcium phosphate (TTCP). The formation of calcium metallates led to a decrease of the solubility of the oxide doped tetracalcium phosphates. The cements based on tetracalcium phosphates mixed with SiO2 and TiO2 exhibit a significant increase of the compressive strengths (65 MPa of pure cement up to 80 MPa (SiO2) and 100 MPa (TiO2)). A second approach to decrease the viscosity of CPC pastes considered the interactions between the particle surfaces and the liquid cement phase. To disperse agglomerates and improve the injection properties of CPC, biocompatible components were added to the liquid phase. As a result the injection properties of the TTCP/DCPA cement improved significantly. The use of 500 mM trisodium citrate solution as liquid phase changed the viscosity of the cement paste to a point, where complete injectability (> 95%) through an 800 mm diameter hypodermic needle could be achieved at low loads (20 N). In order to transfer the results of a multi-constituent cement to a single reactive component cement, different fine-particle-sized fillers were added to mechanically activated, monomodal α-tricalcium phosphate (α-TCP) cement. The inert fillers dicalcium phosphate anhydrous (DCPA), titanium dioxide (TiO2) and calcium carbonate (CC) were added to the α-TCP-matrix in different concentrations. For an effective ionic modification a 500 mM trisodium citrate solution was used as liquid phase as in the aforementioned TTCP/DCPA cement system. Only the combination of a bimodal particle size distribution and trisodium citrate solution led to a nearly complete injectability and a significantly increase of the mechanical stability of CPC.
15

Synthese und Charakterisierung von Knochenmineral-ähnlichen Calciumphosphaten Herstellung eines synthetischen Biomaterials /

Tadic, Dražen. January 2003 (has links) (PDF)
Bochum, Univ., Diss., 2003.
16

Influence of bone cements on bone screw interfaces in the third metacarpal and metatarsal bones of horses

Hirvinen, Laura J.M. 26 August 2009 (has links)
No description available.
17

Bio-inspired structured composites for load-bearing bone graft substitution

Galea, Laetitia 21 May 2015 (has links) (PDF)
Natural composites, in particular nacre, often combine high strength and toughness thanks to highly ordered architectures and controlled geometries of the reinforcement components. However, combining strength, toughness and resorbability in synthetic materials remains a challenge in particular in the field of bone graft substitutes. In the present study, calcium phosphate-(CaP-)based materials with designed architectures inspired from natural composite materials were achieved. CaP platelets obtained by precipitation in organic medium were first aligned in chitosan matrices by solvent casting in ambient conditions. Efficient strengthening was obtained with 15 vol-% ceramic, reaching cortical bone strength (150 MPa) and preserving good ductility (5 % deformation). In a weak magnetic field, high spatial arrangement without percolation was maintained up to 20 vol-%. With directional freezing, good alignment of the platelets could be pushed up to 50 vol-%. In parallel, in situ recrystallization of CaP blocks in hydrothermal conditions led to hierarchical structures. The strength and the work-of-fracture were enhanced (300%) thanks to a change of failure mode.
18

Bio-inspired structured composites for load-bearing bone graft substitution

Galea, Laetitia 03 March 2015 (has links)
Natural composites, in particular nacre, often combine high strength and toughness thanks to highly ordered architectures and controlled geometries of the reinforcement components. However, combining strength, toughness and resorbability in synthetic materials remains a challenge in particular in the field of bone graft substitutes. In the present study, calcium phosphate-(CaP-)based materials with designed architectures inspired from natural composite materials were achieved. CaP platelets obtained by precipitation in organic medium were first aligned in chitosan matrices by solvent casting in ambient conditions. Efficient strengthening was obtained with 15 vol-% ceramic, reaching cortical bone strength (150 MPa) and preserving good ductility (5 % deformation). In a weak magnetic field, high spatial arrangement without percolation was maintained up to 20 vol-%. With directional freezing, good alignment of the platelets could be pushed up to 50 vol-%. In parallel, in situ recrystallization of CaP blocks in hydrothermal conditions led to hierarchical structures. The strength and the work-of-fracture were enhanced (300%) thanks to a change of failure mode.:Acknowledgements v Summary vii Background vii Thesis outline viii Part I: “Brick-and-mortar” structures with discrete reinforcement components ix Part II: “Textured” structures with continuous reinforcement components x Zusammenfassung xi Hintergrund xi Doktorarbeit Gliederung xii Teil I: “Ziegelmauer-Architektur” mit diskreten Verstärkungskomponenten xiii Teil II: “ Texturierte” Strukturen mit kontinuierlichen Verstärkungskomponenten xiv Chapter 1: General introduction 1 Bone grafting 1 CaP ceramics 1 How to improve toughness of CaP ceramics? 2 Importance of structure design: bio-inspiration 2 What mechanical properties should be reached? 5 Specific aims 5 Two general approaches to reach the goal 6 Nacre-inspired “brick-and mortar” structures (Part I) 6 Textured ceramic monoliths (Part II) 6 References 7 Chapter 2: Theoretical calculations 11 Introduction 12 Theoretical tensile strength of β-TCP platelets and critical size for flaw tolerance 13 Optimal aspect ratio 15 Composite strength and stiffness 17 Limitations 19 References 19 PART I: NACRE-INSPIRED “BRICK-AND-MORTAR” STRUCTURES Chapter 3: Synthesis of sub-micrometer calcium phosphate platelets 23 Introduction 24 ii Materials and Methods 25 Precipitation method 25 Reaction parameters 25 Characterization 26 Statistical analysis of results 28 Results 28 Reproducibility of standard experiments 28 Increase of the reagent volume to increase the productivity 30 Increase of the precursors concentration to increase the productivity and modify the particles 30 Increase of titration rate to simplify the process 32 Influence of temperature on the particles 35 Effect of the pH value on the particles 37 Effect of a longer reaction time on the particle stability 40 Study of the influence of variations of the Ca/P molar ratio 42 Discussion 43 Reproducibility 43 Productivity 44 CaP crystal shape 45 Crystal purity 47 Aspect ratio 48 Critical thickness 49 Uniformity of primary particles 50 Non agglomerated 51 General points 52 Conclusions 52 References 53 Chapter 4: Kinetics study of the calcium phosphate platelets growth 57 Introduction 58 Theory 58 Materials and methods 60 Materials and sample preparation 60 Characterization methods 61 Results 62 Visual observations during manipulations 62 SEM observations 62 XRD results 66 Size measurements 68 Kinetics calculations 70 Discussion 74 Nucleation and assembly mechanism 74 Reaction kinetics 76 Control of size and aspect ratio 76 Conclusions 77 References 78 Chapter 5: Structural design of bio-inspired composites by solvent casting 81 Foreword 82 Introduction 82 Experimental section 84 iii Synthesis of resorbable ceramic platelets 84 Solvent casting to prove the reinforcement efficiency of DCP platelets 84 Magnetization of the platelets 85 Maintaining the orientation during drying of an hydrogel matrix 86 Results 87 Synthesis of resorbable ceramic platelets 87 Solvent casting to prove the reinforcement efficiency of CaP platelets 87 Magnetization of the platelets 91 Maintaining the orientation during drying of an hydrogel matrix 93 Discussion 95 Detrimental effect of β-TCP platelets in chitosan 95 Efficient reinforcement with DCP platelets up to a given volume fraction 96 Threshold value for strength improvement 97 Fitting the experimental results with theoretical equations 98 Conclusions 101 References 101 Chapter 6: Biodegradable, strong and tough nacre-inspired structures obtained by freezecasting 105 Introduction 106 Experimental section 108 Synthesis of resorbable ceramic platelets 108 Preliminary freeze-casting tests with β-TCP-based slurries 108 Determination of adequate freeze-casting parameters for hydrogels-CaP slurries 108 Integration of CaP platelets and local planar alignment 109 Attempts to globally align porosity in two directions 109 Densification and consolidation 110 Tensile testing 110 Results 111 Preliminary freeze-casting tests with β-TCP-based slurries 111 Determination of adequate freeze-casting parameters for hydrogels-CaP slurries 112 Integration of CaP platelets and local planar alignment 113 Attempts to globally align porosity in two directions 119 Densification and consolidation 121 Tensile testing 121 Discussion 122 Conclusions 124 References 125 PART II: TEXTURED CERAMIC MONOLITHS Chapter 7: Micro-texturing by recrystallization of calcium phosphate blocks in hydrothermal conditions 127 Introduction 128 Materials and Methods 130 Samples characterization 132 Results 133 Macroscopic observations 133 Microstructural changes (SEM) 133 Crystalline phase conversion (XRD) 139 iv Mechanical properties 142 Fractured surfaces 142 Discussion 145 Conclusions 150 References 150 Chapter 8: Toughening of textured calcium phosphate blocks by polymer impregnation 155 Foreword 156 Introduction 156 Materials and Methods 157 Samples preparation 157 Characterization 158 Results 158 Porosity and microstructure 158 Composition 161 Mechanical properties 161 Discussion 162 Conclusions 164 References 164 Chapter 9: Synthesis and outlook 167 Curriculum Vitae 171

Page generated in 0.051 seconds