Spelling suggestions: "subject:"valor transmissão"" "subject:"calor transmissão""
71 |
Recobrimento de comprimidos em leito de jorro bi-dimensional : analise do crescimento e transferencia de calor gas-particulaAyub, Gamel Said Eduardo 22 July 1993 (has links)
Orientador: Sandra Cristina dos Santos Rocha / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-18T22:04:25Z (GMT). No. of bitstreams: 1
Ayub_GamelSaidEduardo_M.pdf: 4503932 bytes, checksum: cc6bce105e881876cf5ad34785074d7d (MD5)
Previous issue date: 1993 / Resumo: Neste trabalho objetivou-se o estudo da transferência de calor fluido-partícula, da taxa de crescimento da partícula, kl, e eficiência do processo, ?, no recobrimento de comprimidos em um leito de jorro bi-dimensional. As partículas utilizadas foram placebos no formato lenticular, de comprimidos reais, com dp = 7,2117 X 10-3 m e dp = 7,8039 X 10-3 m e esferidades de 0,9510 e 0,9673, respectivamente. Como solução de recobrimento foi utilizada uma solução aquosa polimérica a 50°C. O leito de jorro utilizado foi construído em acrílico e com a possibilidade de variação do ângulo da base inclinada. Os experimentos foram realizados com ângulos de base 30, 45 e 60°, na faixa de temperatura de 70°C a 85°C e vazões de solução de recobrimento na faixa de 7,0 ml/min a 13,0 ml/min. Um atomizador de duplo fluido com mistura externa foi instalado no topo do leito, e a solução de recobrimento foi alimentada em contra-corrente com o ar de jorro. Determinou-se o coeficiente médio de transferência de calor, que foi expresso através do número de Nusselt, Nu, verificando-se que Nu aumenta quando Re e Ws/Wg aumentam e quando Ho/?dp e tg(?/2) diminuem. Foi efetuada uma análise dimensional do processo e os dados experimentais foram ajustados, através dos métodos dos mínimos quadrados, obtendo-se a seguinte correlação: Nu=0,9892.Pr1/3.Re1,6421.(Ws/Wg)¿1,0,7808.(Ho/?dp)¿1,3363.[tg(?/2)]0,1806
O sistema experimental, a formulação da solução e as temperaturas utilizadas no processo mostraram-se adequadas à verificação da variação da massa dos comprimidos com o tempo do processo de recobrimento. Verificou-se uma relação linear do crescimento da partícula com o tempo, sendo esse crescimento função de Ws/Wg. Nas condições estudadas, a temperatura não apresentou influência significativa na taxa de crescimento, kl, e nem na eficiência do processo, ?. Os valores obtidos para eficiência foram considerados satisfatórios, variando entre 57% e 81% para a inclinação de 45°. O melhor ângulo de trabalho foi o de 45°, apresentando boa circulação dos comprimidos levando assim a um recobrimento uniforme e altas taxas de crescimento e eficiência do recobrimento. O recobrimento foi considerado satifatório por observação visual, com boa adesão e não ocorrendo o fenômeno de "peeling", nem penetração da solução / Abstract: The study of fluid-particle heat transfer, particle growth rate, kl, and process efficiency, ?, applied to the coating of tablets on a two-dimensional spouted bed, was the objectives of this work. The used particles were placebos in lenticular shapes of real tablets, with dp = 7,2117 X 10-3 m and dp = 7,8039 X 10-3 m and sphericity equal to 0,9510 and 0,9673 respectively. As for the coating solution, it was used an aqueous polimeric solution at about 50°C. The spouted bed used was built in plexiglass with the likeliness of slant angle variation. The experiments were carried out with three different slant anglesj 30°, 45°, 60°, in a temperature range of 70°C - 85°C and solution flow rate in the range of 7,0 - 13,0 ml/min. A spraying nozzle of double fluid with externa I mixture was installed on the bed top, and the coating solution was fed counter-current to the spout flow. The medium head transfer coeficient was determined, and it was expressed by the non-dimensional Nusselt number, Nu, verifying that Nu increases when Re and Ws/Wg increase and when Ho/?dp and tg(?/2) decrease. It was carried out a dimensional analysis of the process and the experimental data were fit through a least square method, obtaining the following relation: Nu=0,9892.Pr1/3.Re1,6421.(Ws/Wg)¿1,0,7808.(Ho/?dp)¿1,3363.[tg(?/2)]0,1806 The experimental system, the coating solution formulation and the temperature used in the process showed up to be adequa te to the ver if ication of tablets mass var iation concerning the time of coating. A linear relationship between the particle growth and time was verified, and this growth being function of Ws/Wg. As for the temperature, it didn't present any significant influence either upon the growth rate, kl,or on the process efficiency, ?, in the studied conditions. The obtained values for efficiency were considered satisfactory, bearing a variation between 57% and 81% for 45° of falanted angle. The best work angle was 45°, showing high growth rates and coating efficiency. The coating was considered satisfactory on eye observation, with good adhesion with no peeling and no solution penetration either / Mestrado / Engenharia de Processos / Mestre em Engenharia Química
|
72 |
A method for measuring contact angle and influence of surface fluid parameters on the boiling heat transfer performance /Cunha, Alex Pereira da. January 2019 (has links)
Orientador: Elaine Maria Cardoso / Resumo: O avanço de novas tecnologias, associado à minimização dos custos de fabricação e instala-ção, constitui um grande desafio para a área de refrigeração, uma vez que a geração de calor tem aumentado gradativamente nos últimos anos. Assim, a busca de novos fluidos com pro-priedades térmicas superiores aos comumente usados tornou-se indispensável para melhorar a eficiência energética. Nas últimas décadas os nanofluidos - dispersões de partículas de escala nanométrica (1 a 100nm) em um fluido-base - têm atraído especial interesse não somente da comunidade acadêmica, mas também da indústria em áreas como: a microeletrônica, microflu-ídica, transporte, manufatura, assistência médica, entre outras. O melhor desempenho térmico e a vasta gama de aplicações fazem dos nanofluidos potenciais substitutos dos refrigerantes utilizados em diversos segmentos da engenharia. Dentro desse contexto, o presente trabalho teve como objetivos: o estudo teórico e experimental da influência das propriedades termofísi-cas e concentração de nanofluidos, bem como, das características geométricas da superfície aquecedora sobre o ângulo de contato e a molhabilidade. Também, atenção foi dada à prepa-ração e caracterização dos nanofluidos (Al2O3-água e Fe2O3-água), por meio da análise expe-rimental da condutividade térmica e da viscosidade dinâmica para diferentes concentrações; uma bancada experimental, para aquisição de imagens de gota séssil, foi construída a fim de viabilizar as análises de ângulo de conta... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The advance of new technologies, associated to the minimization of manufacturing and installation costs, presents a great challenge for the refrigeration area, since the heat generation has increased in recent years. Thus, the search for new fluids with thermal properties higher than those commonly used has become indispensable to improve energy efficiency. In recent decades, nanofluids-dispersions of nanometer-scale particles (1 to 100 nm) in a base fluid - have attracted special interest not only from the academic community but also from industry in areas such as microelectronics, microfluidics, transport, manufacturing, medical assistance, among others. In this context, the present work had the following goals: the theoretical and experimental study of the influence of thermophysical properties and nanofluid concentration, as well as the geometric characteristics of the heating surface on the contact angle and wetta-bility. Attention was also given to the preparation and characterization of nanofluids (Al2O3-water and Fe2O3-water) by the experimental analysis of thermal conductivity and dynamic viscosity for different concentrations; an experimental apparatus for the acquisition of sessile droplet images was designed in order to analyze the contact angle and wettability; and a computational routine was developed to obtain the drop profile and the surface-fluid interaction for the different nanofluids and surfaces used. Based on database, it was possible to evaluate the pre... (Complete abstract click electronic access below) / Doutor
|
73 |
Convecção mista em painéis fotovoltaicosOliveira, João Gabriel Gomes de 27 August 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2018. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) e Fundação de Apoio a Pesquisa do Distrito Federal (FAPDF). / Um estudo numérico da transferência térmica por convecção natural, forçada e mista em um painel fotovoltaico inclinado, em regime laminar e turbulento, foi realizado. Este painel é formado por um conjunto de 16 módulos solares de 1 m (comprimento) x 0,5 m (largura). As equações do modelo matemático foram resolvidas numericamente pelo Método dos Volumes Finitos, utilizando ferramentas CFD. A metodologia RANS foi aplicada para realizar as simulações numéricas do escoamento em regime turbulento, utilizando o modelo de turbulência SST. O modelo numérico foi validado por meio de ensaios experimentais e correlações empíricas presentes na literatura que estimam a transferência térmica em placas planas inclinadas. Os resultados numéricos da transferência térmica por convecção natural, forçada e mista nas superfícies (superior e inferior) do painel fotovoltaico são apresentados relacionando o número de Nusselt com os números de Rayleigh, Reynolds e de Richardson, respectivamente. Foi observado que as correlações empíricas de placa plana vertical em regime de convecção natural (condições de vento nulo) e escoamento laminar podem ser utilizadas para uma placa inclinada até 80° com relação a vertical se a componente da gravidade paralela à placa for usada no cálculo do número de Rayleigh. Entretanto, para escoamento turbulento apresentam incerteza de até 25% devido à amplificação de instabilidades térmicas e fluidodinâmicas na superfície superior do painel que não são previstas por tais correlações. Também foi verificado que, para placa plana inclinada, os efeitos da convecção mista devem ser considerados para 1 ≲ Ri ≲ 60. Correlações numéricas para estimar a transferência térmica por convecção forçada e mista são propostas para escoamentos com características típicas encontradas em aplicações de painéis fotovoltaicos. / A numerical study of heat transfer by natural, forced and mixed convection in an inclined photovoltaic panel was accomplished for laminar and turbulent flows. This panel consists of 16 solar modules of 1 m (length) x 0,5 m (width). The mathematical model equations were numerically solved by the Finite Volume Method using CFD tools. The RANS methodology was applied to perform numerical simulations of turbulent flow with the SST turbulence model. The numerical model was validated through experimental assays and comparison with available empirical correlations in the literature that estimate heat transfer in inclined plates. The numerical results of the heat transfer by natural, forced and mixed convection from the upper and bottom surfaces of the photovoltaic panel are presented by relating the Nusselt number to the Rayleigh, Reynolds and Richardson numbers, respectively. It was observed that the empirical correlations of a vertical flat plate in natural convection (zero wind conditions) and laminar flow may be used for a plate inclined up to at least 80° from the vertical position if the component of gravity parallel to the plate is used in the Rayleigh number. However, these empirical correlations might reach up to 25% of uncertainty for turbulent flows due to the amplification of thermal and fluid dynamic instabilities in the upper surface of the panel that are not predicted by such correlations. Furthermore, it was verified for the inclined flat plate that the effects of mixed convection shall be considered for 1 ≲ Ri ≲ 60. Numerical correlations for estimating forced and mixed convection heat transfers are suggested for the flows with typical characteristics encountered in photovoltaic panel applications.
|
74 |
Convecção natural em cavidades triangulares /Aquino, Felipe Rinaldo Queiroz de. January 2001 (has links)
Orientador: Maurício Araújo Zanardi / Resumo: Neste trabalho estuda-se a convecção natural laminar em regimes permanente e transiente em cavidades triangulares isósceles. Para a determinação das distribuições de velocidades e temperaturas são utilizadas as equações de conservação da massa, quantidade de movimento e de energia, com a aproximação de Boussinesq. A solução do sistema de equações diferenciais é feita através de um método de volumes finitos utilizando o esquema de discretização "Power-Law" proposto por Patankar e o procedimento SIMPLE é empregado para obtenção de equações de correção de pressões. Os sistemas de equações algébricas encontrados são solucionados numericamente por um algoritmo "line-by-line", que é uma combinação de um método direto TDMA para problemas unidimensionais com o método iterativo de Gauss-Siedel. Foram obtidas soluções para diversas combinações de condições de contorno de temperaturas conhecidas e paredes adiabáticas e as comparações com os resultados existentes na literatura comprovam a confiabilidade do modelo e do código computacional desenvolvidos. São apresentadas ainda soluções quando se consideram fluxos de calor constantes e variáveis com o tempo em uma das superfícies da cavidade. A influência do valor do número de Grashof e da razão de aspecto da cavidade é também discutida. / Abstract: In this work the laminar natural convection in enclosures of isosceles triangular shape is studied. Both the steady state and the transient regimes are included. The mass conservation, momentum and energy equations are used for the velocity and temperature profiles determination. The Boussinesq approach is also considered. The solution of the differential equation set is performed by using a finite volume method. The discretization scheme chosen was the Patankar's Power-Law Scheme and the SIMPLE algorithm is adopted to get a pressure correction equation. The resultant algebraic equations are solved by a line-by-line procedure that is a combination of a direct method (TDMA) and an iterative Gauss-Siedel method. The solution for some different boundary condition, involving prescribed temperatures and adiabatic walls, were obtained and were compared with the literature results. The good agreement between them validates the developed mathematical model and computational code. Here it is also presented solutions for the case of a constant or time dependent heat flux imposed over one of the sides of the enclosure. The influence of the Grashof number and the enclosure aspect ratio is discussed. / Doutor
|
75 |
Estudo numérico e experimental do resfriamento convectivo de vegetais cilíndricos /Massoni, Paulo Rogério. January 2002 (has links)
Orientador: Jorge Roberto Pimentel / Banca: Marcos Antonio Sanches Vieira / Banca: Ricardo Egydio de Carvalho / Resumo: O resfriamento de produtos agrícolas, em ambientes com atmosfera controlada, é uma das técnicas que tem sido utilizada por produtores e indústrias do setor, sendo importante se ter informações sobre a influência de parâmetros que atuam durante o processo. Neste trabalho, foi desenvolvido um modelo numérico unidimensional usando-se um método explícito de aproximação das derivadas de equações diferenciais por diferenças finitas, para solucionar a equação da condução de calor em sólidos com alto teor de água e de formato cilíndrico, que estejam submetidos a um fluxo de ar resfriado. Utilizando o modelo, simulou-se a influência de variáveis físicas e geométricas na distribuição das temperaturas radiais em cilindros hipotéticos, obtendo-se resultados coerentes com o comportamento previsto para tal situação. Foram feitas medidas experimentais das temperaturas em diferentes localizações radiais em alguns vegetais com formato aproximadamente cilíndrico e, os resultados dessas medidas, comparados com as previsões numéricas, revelando boa concordância dentro da faixa do erro experimental. / Abstract: Cooling in atmosphere controlled environment is one of the methods used in the food preservation and processing industry. For best process improvement information, for example, concerning the influence of different parameters on the internal temperature values are of interest. The present work deals with a simple numeric model developed using a explicit finite-differences scheme for solve the one-dimensional cylindrical transient heat equation. The equation is solved with a field temperature inicial condition, simetry center boundary condition and a pure convection surface boundary condition after normalizing the equation system. A FORTRAN program was develop to solve the resulting matricial system to obtain the transient radial temperature distribution as a function of convective heat coefficient, Fourier number, thermal diffusivity and Biot number. The experimental setup consisted of a retangular duct througt witch cooled air circulated by a blower. Inside the duct fresh approximated cylindrical shapped samples of food products have they radial temperature measured in four different location using iron-constantan thermocouples. The results show that there is a good a agreement between the experimentally measured temperature values and that computed using numeric model. / Mestre
|
76 |
Uso de analogias como recurso didático na disciplina de transmissão de calor /Matelli, José Alexandre. January 2018 (has links)
Banca: Álvaro de Souza Dutra / Banca: Messias Borges da Silva / Banca: Estaner Claro Romão / Banca: Carlos Alberto Moreira dos Santos / Bancs: Durval Rodrigues Junior / Resumo: Disserta-se nessa tese sobre o uso de analogias como recurso didático na disciplina de transmissão de calor. A aplicação de analogias no ensino é revisada na literatura, de modo que se estabeleça um referencial teórico que justifique este uso. Assim, propõe-se que a analogia possa ser interpretada como um mediador simbólico de Vigotski. Usos de analogias adaptadas ou desenvolvidas em sala de aula pelo autor da presente tese são apresentados. As impressões do autor acerca da receptividade dos alunos ao recurso são discutidas, bem como alguns casos de interação com os alunos são apresentados / Abstract: The use of analogies as a didactic resource in the discipline of heat transfer is discussed in this thesis. The application of analogies in teaching is reviewed in the literature, so that a theoretical framework that justifies the use of analogies can be established. Thus, it is proposed that the analogy can be interpreted as a Vigotski's symbolic mediation. Uses of analogies either adapted or developed in the classroom by the author of this thesis are presented. The impressions of the author about the students' receptivity to the resource are discussed, as well as some cases of interaction with the students are presented
|
77 |
Modelagem do escoamento e da transferência de calor ao longo de tubos capilares não adiabáticosSilva, Marcelo Camargo da [UNESP] 23 April 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-04-23Bitstream added on 2014-06-13T19:29:57Z : No. of bitstreams: 1
silva_mc_me_ilha.pdf: 749066 bytes, checksum: 898e72bcde1702f0b46c2b4a5c84198f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Neste trabalho, apresenta-se um modelo numérico do escoamento e da transferência de calor, no regime transiente, de fluidos refrigerantes no interior de tubos capilares, largamente usados como dispositivos de expansão em sistemas de refrigeração e condicionamento de ar de pequeno porte. Os tubos capilares aqui analisados formam, em parte de suas extensões, um trocador de calor em contracorrente com a linha de sucção do compressor, conhecido como trocador de calor tubo capilar-linha de sucção. A análise do comportamento dinâmico do escoamento é de fundamental importância, pois os tubos capilares são usados em sistemas de refrigeração, que geralmente são controlados pelo método liga-desliga. Tal escoamento é assumido unidimensional e, dependendo da condição no tempo, é dividido em uma região onde o fluido refrigerante encontra-se no estado de líquido sub-resfriado, outra de escoamento bifásico líquido-vapor e outra de vapor superaquecido. O tubo capilar é considerado reto, horizontal, com diâmetro constante e o fenômeno de metaestabilidade do escoamento é desconsiderado. Implementa-se no modelo o procedimento para a simulação de transientes de partida do sistema. A solução do sistema de equações diferenciais, usando o método de Volumes Finitos, é obtida ao longo do tubo até que a condição de bloqueio seja alcançada, ou até que a pressão de evaporação seja atingida, caso o escoamento não esteja bloqueado. Os resultados obtidos são comparados com os dados experimentais disponíveis na literatura e obtidos a partir de outros modelos / This work presents a numerical model to simulate unsteady flow and heat transfer along nonadiabatic capillary tubes, commonly used as expansion devices in small refrigeration and air conditioning systems. These capillary tubes form with the suction line of the compressor, in part of their extension, a counter flow heat exchanger. Such device is called capillary tubesuction line heat exchanger. Analysis of the flow dynamic behavior is very important, since the capillary tubes are used in refrigeration systems generally controlled by on-off method. The flow along the straight and horizontal capillary tube, with constant inner diameter, is divided, depending of time condition, into three regions: a single-phase flow of subcooled liquid, a two-phase flow region and a single phase of flow superheat. The flow is taken as one-dimensional and the metastable flow phenomenon is neglected. The procedure for simulation of the start-up transient period of the system is implemented in the model. The solution of the governing equations is obtained using the Finite Volume method, along the tube until the blocking condition is reached, or until the evaporation pressure is reached, if the flow is not blocked. The numerical results obtained are compared with the experimental date from the literature and with results obtained from other models
|
78 |
Análise térmica do processo de retificação plana sob diferentes condições de lubrificação utilizando técnicas de transferência de calor reversa /Gallo, Rubens. January 2014 (has links)
Orientador: Eduardo Carlos Bianchi / Co-orientador: Santiago del Rio Oliveira / Banca: Sandro Donnini Mancini / Banca: Manoel Cleber de Sampaio Alves / Banca: Alessandro Roger Rodrigues / Banca: Leonardo Roberto da Silva / O Programa de Pós Graduação em Ciência e Tecnologia de Materiais, PosMat, tem carater institucional e integra as atividades de pesquisa em materiais de diversos campi / Resumo: As técnicas de lubri-refrigeração, Convencional e Mínima Quantidade de Lubrificante - MQL, foram analisadas e o particionamento de energia na região de contato foram determinadas para o processo de retificação plana de uma peça de aço ABNT 1020 com um rebolo convencional de Óxido de Alumínio (Al2O3), para diferentes profundidades de retificação. Para isso foi desenvolvido um modelo térmico obtido pela equação da difusão de calor bidimensional transiente com as suas condições de contorno, a equação resultante foi dicretizada pelo método dos Volumes Finitos, com formulação, implícita no tempo devido ao fato desta técnica não apresentar limitação quanto à escolha do intervalo de tempo. O sistema de equação resultante foi resolvido pelo método das Relaxações Sucessivas (Sucessives Over Relaxation). A técnica de transferência de calor reversa da Seção Àurea foi aplicada para estimar o fluxo de calor que entra na peça pela interface peça/rebolo. As temperaturas geradas pelo modelo térmico foram comparadas com as temperaturas experimentais medidas por um termoar tipo K localizado a uma determinada distância da superfície de retificação. As técnicas de lubri-refrigeração foram comparadas mostrando que para o método de lubri-refrigeração MQL em relação ao Convencional , o fluxo de calor que entra na peça foi 43% maior para a profundidade de retificação de 30um, 137% para 45um e 184% para 60um, enquanto que o calor removido pelo fluido de corte na lubri-refrigeração MQL representa 2,62% para 30um, 4,35 para 45um e 5,21% para 60um em relação ao Convencional / Abstract: Techniques for lubrification and cooling. Conventional and Minimum Quantify Lubrificant - MQL, were determined for the process of grinding a plane workpiece of steel SAE 1020 with a conventional grinding Aluminum Oxide (Al2O3), for different depths of rectification. For that obtained by a thermal model of transient two-dimensional heat diffusion with its boundary conditions, the equation resulting equation was discretized by the Finite Volume Method with implicit formulation in time was developed due to the fact that this techique does not introduce restriction on the choise time interval. The resulting system of equations was solved by the method of SOR (Successives Over Relaxation). The technique of reverse transfer of heat from the Golden Section was applied to estimate the flow of theat that enters the part number for the workpiece/wheel interface. The temperature generated by the thermal model were compared with measurements by a K-type thermocouple located at a given distance from the surface grinding experimental temperatures. The lubrification and cooling techniques were compared showing that for the method of lubrification and cooling compared to conventional MQL, the heat flux entering the number was 43% higher for the grinding depth of30um, 137% to 45um and to 184% for 60um, while the heat removed by the cutting fluid in the lubrification and cooling MQL is 2.62% to 30um, 45um 4.35% to 5.21% for 60 um of the Conventional / Doutor
|
79 |
Transferência tridimensional acoplada de calor e de umidade em solos sob edificações / Gerson Henrique dos Santos ; [orientado por Nathan Mendes]Santos, Gerson Henrique dos January 2003 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2003 / Inclui bibliografias / Após a crise mundial de energia na década de 70 e o crescente interesse em reduzir o consumo de energia de forma racional, vários programas computacionais foram desenvolvidos para simular o comportamento termoenergético de edificações. No entanto, estes c / After the wide world crisis of energy in the 70#s and the interest in energy consumption reduction, some computational programs had been developed to simulate the building energy performance. However, these codes present some simplifications on their calc
|
80 |
Análise numérica do escoamento e da transferência de calor no interior de refrigeradores domésticos / Michel Vinícius Werkhäuser ; orientadores, Nathan Mendes e Álvaro Toubes PrataWerkhäuser, Michel Vinícius January 2004 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2004 / Inclui bibliografia / Estuda-se trabalho os padrões de escoamento e fluxo de calor dentro de um refrigerador domético submetido a várias condições de contorno de forma a identificar a formação de regiões onde o ar está quente ou excessivamente frio devido a sua estratificação. / The main goal of this work is to investigate the flow patterns and the heat transfer inside a domestic refrigerator submitted to several boundary conditions so that the formation of regions where the air is either warm of excessively cold due to air beddi
|
Page generated in 0.0638 seconds