• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 1
  • Tagged with
  • 18
  • 18
  • 15
  • 15
  • 9
  • 8
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do peróxido de hidrogênio sobre a resistência de união de restaurações de resina composta, com margens em esmalte e dentina, confeccionadas com sistema adesivo multimodo

Gomes, Lívia Roberta Malpeli January 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-04-26T17:15:10Z No. of bitstreams: 1 2015_LíviaRobertaMalpeliGomes.pdf: 2467337 bytes, checksum: f63d02386d1ad471fbdd0accb660fd26 (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2016-05-04T14:37:52Z (GMT) No. of bitstreams: 1 2015_LíviaRobertaMalpeliGomes.pdf: 2467337 bytes, checksum: f63d02386d1ad471fbdd0accb660fd26 (MD5) / Made available in DSpace on 2016-05-04T14:37:52Z (GMT). No. of bitstreams: 1 2015_LíviaRobertaMalpeliGomes.pdf: 2467337 bytes, checksum: f63d02386d1ad471fbdd0accb660fd26 (MD5) / Restaurações adesivas e outros procedimentos estéticos, tais como clareamento dentário, são alvos da procura de pacientes que buscam melhorar o sorriso. No entanto, pouco se sabe sobre a interação entre esses dois procedimentos, uma vez que o mecanismo de ação do peróxido de hidrogênio se baseia na quebra de ligação das moléculas orgânicas, tais como as presentes na interface adesiva. Desta forma, o objetivo do presente estudo foi avaliar o efeito do peróxido de hidrogênio sobre a resistência de união de restaurações de resina composta envelhecidas no período de 12 meses, confeccionadas com um sistema adesivo multimodo, nas formas autocondicionante e convencional, apresentando margens em esmalte e dentina. Metodologia: O sistema adesivo Scotchbond Universal foi utilizado para a confecção de restaurações de resina composta em 48 dentes bovinos, com margens em esmalte e dentina, formando os seguintes grupos: G1 (Scotchbond Universal utilizado de modo convencional controle), G2 (Scotchbond Universal utilizado de modo convencional e clareado), G3 (Scotchbond Universal utilizado de modo autocondicionante controle) e G4 (Scotchbond Universal utilizado de modo autocondicionante e clareado). Os grupos foram armazenados por períodos de 24horas e 12 meses e em seguida submetidos à termociclagem e clareados. As restaurações foram seccionadas em forma de palitos e submetidas ao teste de microtração. O conjunto de dados de resistência de união (MPa) foi submetido à análise de variância de dois critérios fixos (“tratamento” e “tempo”), a qual foi complementada pelo teste de Tukey para comparação múltipla aos pares. O nível de significância adotado foi de 1% para as inferências estatísticas. Resultados: para as restaurações com margem em esmalte, observou-se diferença estatisticamente significativa entre G3 e os demais grupos no período de 24 horas. Para o período de 12 meses, foi observada diferença estatisticamente significativa entre G4 e os demais grupos. Quando comparado o mesmo grupo nos diferentes tempos, o grupo G3 e G4 apresentaram os menores valores de resistência de união nos períodos de 24 horas e 12 meses respectivamente. Para as restaurações com margem em dentina, não foi observado diferença estatísticas significativas entre os grupos no período de 24 horas. Entretanto, no período de 12 meses, G3 apresentou os maiores valores de resistência de união à dentina, sendo superior a G1 e G2. Quando comparou o mesmo tratamento nos diferentes períodos, o G2 apresentou maior valor de resistência de união à dentina no período de 12 meses. Conclusão: De acordo com os resultados obtidos, é possível observar uma tendência na redução dos valores de resistência de união na presença do peróxido de hidrogênio em restaurações envelhecidas com margem em esmalte, confeccionadas com o sistema Scotchbond Universal no modo autocondicionante. Para margens em dentina, o sistema adesivo quando utilizado no modo autocondicionante, observamos os maiores valores de resistência de união, sendo isso reduzido na presença do peróxido de hidrogênio. / Adhesive restorations and other cosmetic procedures, such as tooth whitening, are mostly required by patients in order to improve their smile. However, there is no much information about the interaction of these two procedures, once the mechanism of action of hydrogen peroxide is based on breaking organic molecules, such as the ones present in the adhesive interface. Therefore, the purpose of this study was to evaluate the effect of hydrogen peroxide on the bonding strength of 12 months aged composed resin restorations, made with a universal multimode adhesive system in self-etching and conventional forms, with margins in enamel and dentin. Methodology: Scotchbond Universal adhesive system were used to make composed resin restorations in 48 bovine teeth,with margins in enamel and dentin, and formed the following groups: G1 (Scotchbond Universal using in Etch-and-Rinse mode control), G2 (Scotchbond Universal using Etch-and-Rinse and cleared), G3 (Scotchbond Universal using Self-Etch control mode) and G4 (Scotchbond Universal using Self-Etch mode and cleared).The groups were stored for a period of 24 hours or 12 months, being submitted to thermal cycling and whitening after that. The restorations were sectioned into sticks and submitted to micro tensile test. The bonding strength data (MPa) set was analyzed with two-way ANOVA ("treatment" and "time"), which was complemented by the Tukey test for multiple pair comparisons. The significance level was 1% for statistical inferences. Results: For restorations with margins in enamel, a statistically significant difference was observed between G3 and the other groups in the 24-hour period. For the 12-month period, there was a statistically significant difference between G4 and the other groups. When comparing the same group at different times, G3 and G4 showed the lowest bonding strength values for periods of 24 hours and 12 months, respectively. For restorations with margins in dentin, there was no statistically significant difference between groups in 24-hour period. However, for 12-month period, G3 showed the highest bonding strength to dentin values, even higher than G1 and G2. When comparing the same treatment in different periods, G3 showed higher bonding strength to dentin value over the 12 months. Conclusion: According to the results, there was a tendency to reduce the bond strength values within the presence of hydrogen peroxide for aged restorations with margins in enamel, when the Scotchbond Universal system was used as Self-Etch. For the restorations with dentin margins, when the adhesive system is used in self-etch mode, we observed the highest bonding strength values that was reduced in the presence of hydrogen peroxide.
2

Avaliação da clorexidina na qualidade da camada híbrida de dentes decíduos

Azevedo, Tatiana Degani Paes Leme January 2006 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2006. / Submitted by wesley oliveira leite (leite.wesley@yahoo.com.br) on 2009-11-21T17:49:13Z No. of bitstreams: 1 Tatiana Degani Paes Leme Azevedo.pdf: 5766524 bytes, checksum: 8bbff4bb88fa7e7bd52a526d5c4f808b (MD5) / Approved for entry into archive by Joanita Pereira(joanita) on 2010-01-14T18:25:46Z (GMT) No. of bitstreams: 1 Tatiana Degani Paes Leme Azevedo.pdf: 5766524 bytes, checksum: 8bbff4bb88fa7e7bd52a526d5c4f808b (MD5) / Made available in DSpace on 2010-01-14T18:25:46Z (GMT). No. of bitstreams: 1 Tatiana Degani Paes Leme Azevedo.pdf: 5766524 bytes, checksum: 8bbff4bb88fa7e7bd52a526d5c4f808b (MD5) Previous issue date: 2006 / Recentemente, tem sido observado que a clorexidina apresenta capacidade inibidora das metaloproteinases da matriz dentinária. Estas enzimas são responsáveis pela degradação das fibrilas colágenas. Desta forma, o objetivo deste estudo foi avaliar o uso da clorexidina na qualidade da camada híbrida de dentes decíduos hígidos. A superfície dentinária média de dentes decíduos foi preparada com auxílio de broca carbide no. 330 e alta rotação. No grupo teste, os dentes sofreram condicionamento ácido, aplicação de clorexidina, inserção de adesivo Single Bond e restauração com resina composta Z250. O grupo controle sofreu os mesmos procedimentos com exceção da aplicação do agente antimicrobiano. Vinte e cinco regiões, em cada grupo, foram examinadas por meio de microscopia eletrônica de varredura por examinadores cegos. Foram avaliadas a profundidade das fendas, a condição dos túbulos dentinários, bem como a espessura da camada híbrida. Os dados foram analisados estatisticamente por meio do teste qui-quadrado e t-student a um nível de significância de 5%. Os dois grupos avaliados apresentaram poucas fendas interfaciais sem diferença estatisticamente significante. O grupo teste apresentou um número maior de áreas com camada híbrida visível (68%) quando comparado ao controle (52%). A espessura desta camada foi de 3,28 micrômetros para o grupo controle e 3,33 micrômetros para o grupo teste (p=0,94). Os resultados demonstraram que o uso do protocolo clínico-restaurador com aplicação da clorexidina não interfere na qualidade da camada híbrida, podendo ser indicado para aumentar a sobrevida das restaurações por meio da inibição das metaloproteinases da matriz pela clorexidina. __________________________________________________________________________________________ ABSTRACT / It has recently been observed tha chlorhexidine presents the capacity inhibit the matrix metalloproteinase. They were responsible for the collagen fibrils degradation. Therefore, the object of this study was to assess the use of chlorhexidine on the quality of the hybrid layer of healthy primary teeth. The mean dentinal surface of primary teeth was prepared with the aid of a carbide burr No. 330 and high speed. In the test group, the teeth were subjected to acid etching, chlorhexidine application; Single Bond adhesive insertion and restoration with resin composite Z250. The control group underwent the same procedures, except for the application of the antimicrobial agent. Twenty-five regions were examined by scanning electronic microscopy by blind examiners. Measures of gap and hybrid layer were taken and the dentin tubules conditions were analyzed. The data obtained were statistically analyzed by the chi-square and t-student tests at a 5% level of significance. The groups assessed presented few interfacial gaps without statistically significant difference. The test group presented a larger number of areas with visible hybrid layer (68%) when compared with the control group (52%). The thickness of this layer was 3.28 micrometers for the control group and 3.33 micrometers for the test group (p=0,.4). In this study, the results demonstrated that the use of the clinical-restorative protocol with the application of chlorhexidine does not interfere significantly in the morphological characteristics of the hybrid layer, and it should be indicated to increase the survival of restorations, by means of inhibiting the matrix metalloproteinase by chlorhexidine.
3

Resistência de união e análise quantitativa da camada híbrida através de espectroscopia micro-Raman de quatro sistemas adesivos / Bond Strength and quantitative analysis of the hybrid layer by micro-Raman spectroscopy of four adhesive systems

Hori, Frederico Seidi 11 December 2012 (has links)
Adesivos de frasco único, tanto auto-condicionantes como condicione-e-lave, são misturas complexas de monômeros resinosos hidrofílicos e hidrofóbicos dissolvidos em combinações de água/solvente.Embora a inclusão de monômeros hidrofílicos tenha conseguido altas forças de adesão imediata, estudos têm mostrado que a interface resina-dentina têm se tornado muito mais fraca através do tempo. Nesse estudo através da microtração, avaliamos a resistência adesiva de 4 sistemas adesivos e através da espectroscopia micro-Raman analisamos quantitativamente a camada híbrida formada por esses adesivos. Para a microtração, os fatores de variação foram 2: o tipo de adesivo (AdperScotchbondMulti-Purpose, AdperSingle Bond 2, Adper SE Plus, AdperEasyOne), e o período de armazenamento, em 3 níveis (1 dia, 30 dias, 180 dias), totalizando 12 níveis de variação. As unidades experimentais foram confeccionadas sobre 120 superfícies de dentina de terceiros molares humanos hígidos e não irrompidos (n= 10).Para análise estatística foi utilizado o teste paramétrico de análise de variância ANOVA e o teste de múltipla comparação de Games Howell.Para a espectroscopia micro-Raman foram utilizados 3 dentes para cada sistema adesivo, totalizando 12 dentes (n=3).Os espectros Raman dos espécimes foram registrados num espectrômetro Micro-Raman RENISHAW InVia com excitação em 785 nm (laser de diodo, RENISHAW) acoplado a um microscópio LEICA DM2500M, com estágio motorizado (x;y;z)RENISHAW MS 20 EncodedStage com resoluções lateral e axial de 100 nm e 1 m. Os adesivos condicione-e-lave ScotchbondMulti-Purpose e SingleBonddesse estudo apresentaram os maiores valores de resistência adesiva, apresentando valores dentro de uma faixa de 44,36 a 50,66 MPa, enquanto que os adesivos AdperSE e Easy One apresentaram valores de 17,97 a 24,60 MPa. O adesivo que apresentou os maiores valores de resistência adesiva foi o ScotchbondMulti-Purpose e o que teve o pior desempenho foi o adesivo Easy One. Todos os adesivos apresentaram queda significativa de resistência de união após 30 e 180 dias. Na análise micro- Raman, o adesivo ScotchbondMulti-Purpose mostrou-se mais homogêneo e com valores de penetração do adesivo semelhantes aos do Single Bond e do Easy One. O adesivo SE Plus apresentou a menor penetração do adesivo e a camada híbrida mais fina. Concluímos neste trabalho que avaliando 4 diferentes tipos de adesivos de uma mesma marca, existe uma relação negativa entre as estratégias de adesão (diminuição do número de passos e frascos) e a resistência de união e a qualidade da camada híbrida. / One-bottle adhesives, both self-etching as etch-and-rinse, are complex mixtures of hydrophilic and hydrophobic monomers resin combinations dissolved in water / solvent. Although the inclusion of hydrophilic monomers has achieved high immediate adhesion forces, studies have shown that dentin-resin interface have become much weaker over time. In this study, bond strength of four adhesive systems was evaluated bymicrotensile test and quantitative analyze ofthe hybrid layer was obtained by micro-Raman spectroscopy. For microtensile test, the factors of variation were 2: the type of adhesive (AdperScotchbondMulti-Purpose, AdperSingle Bond 2, Adper SE Plus, AdperEasy One), and the period of storage at 3 levels (1 day, 30 days, 180 days), totaling 12 levels of variation. The experimental units were made on 120 dentin surfaces of intact humanunerupted third molars (n = 10). The parametric analysis of variance ANOVA and multiple comparison Games Howell was used for statistical analysis. For micro-Raman spectroscopy were used three teeth for each adhesive system, with a total of 12 teeth (n = 3). Raman spectra of the samples were recorded on a Micro-Raman spectrometer RENISHAW invia with 785 nm excitation (laser diode, RENISHAW) coupled to a microscope LEICA DM2500M with motorized stage (x, y, z) RENISHAW MS 20 EncodedStage with lateral and axial resolutionof 100 nm and 1 microns. Etch-and-rinse adhesives ScotchbondMulti-Purposeand SingleBond of this study showed the highest bond strength values, with values within a range from 44.36 to 50.66 MPa, whereas the self-etch adhesives SE Plusand Easy One had values of 17.97 to 24.60 MPa. The adhesive that showed the highest bond strength was ScotchbondMulti-Purpose and the worst performance was fromEasy One.All adhesives showed a significant decrease in bond strength after 30 and 180 days. In micro-Raman analysis, the ScotchbondMulti-Purpose was more homogeneous and had penetration values similar to those of the adhesive Single Bond and Easy One. The SE Plus had the lowest penetration of the adhesive and the thinner hybrid layer. We conclude that evaluating 4 different types of adhesives of the same brand, there is a negative relationship between the strategies of adhesion (decreasing the number of steps and bottles) and bond strength and quality of the hybrid layer.
4

Resistência de união e análise quantitativa da camada híbrida através de espectroscopia micro-Raman de quatro sistemas adesivos / Bond Strength and quantitative analysis of the hybrid layer by micro-Raman spectroscopy of four adhesive systems

Frederico Seidi Hori 11 December 2012 (has links)
Adesivos de frasco único, tanto auto-condicionantes como condicione-e-lave, são misturas complexas de monômeros resinosos hidrofílicos e hidrofóbicos dissolvidos em combinações de água/solvente.Embora a inclusão de monômeros hidrofílicos tenha conseguido altas forças de adesão imediata, estudos têm mostrado que a interface resina-dentina têm se tornado muito mais fraca através do tempo. Nesse estudo através da microtração, avaliamos a resistência adesiva de 4 sistemas adesivos e através da espectroscopia micro-Raman analisamos quantitativamente a camada híbrida formada por esses adesivos. Para a microtração, os fatores de variação foram 2: o tipo de adesivo (AdperScotchbondMulti-Purpose, AdperSingle Bond 2, Adper SE Plus, AdperEasyOne), e o período de armazenamento, em 3 níveis (1 dia, 30 dias, 180 dias), totalizando 12 níveis de variação. As unidades experimentais foram confeccionadas sobre 120 superfícies de dentina de terceiros molares humanos hígidos e não irrompidos (n= 10).Para análise estatística foi utilizado o teste paramétrico de análise de variância ANOVA e o teste de múltipla comparação de Games Howell.Para a espectroscopia micro-Raman foram utilizados 3 dentes para cada sistema adesivo, totalizando 12 dentes (n=3).Os espectros Raman dos espécimes foram registrados num espectrômetro Micro-Raman RENISHAW InVia com excitação em 785 nm (laser de diodo, RENISHAW) acoplado a um microscópio LEICA DM2500M, com estágio motorizado (x;y;z)RENISHAW MS 20 EncodedStage com resoluções lateral e axial de 100 nm e 1 m. Os adesivos condicione-e-lave ScotchbondMulti-Purpose e SingleBonddesse estudo apresentaram os maiores valores de resistência adesiva, apresentando valores dentro de uma faixa de 44,36 a 50,66 MPa, enquanto que os adesivos AdperSE e Easy One apresentaram valores de 17,97 a 24,60 MPa. O adesivo que apresentou os maiores valores de resistência adesiva foi o ScotchbondMulti-Purpose e o que teve o pior desempenho foi o adesivo Easy One. Todos os adesivos apresentaram queda significativa de resistência de união após 30 e 180 dias. Na análise micro- Raman, o adesivo ScotchbondMulti-Purpose mostrou-se mais homogêneo e com valores de penetração do adesivo semelhantes aos do Single Bond e do Easy One. O adesivo SE Plus apresentou a menor penetração do adesivo e a camada híbrida mais fina. Concluímos neste trabalho que avaliando 4 diferentes tipos de adesivos de uma mesma marca, existe uma relação negativa entre as estratégias de adesão (diminuição do número de passos e frascos) e a resistência de união e a qualidade da camada híbrida. / One-bottle adhesives, both self-etching as etch-and-rinse, are complex mixtures of hydrophilic and hydrophobic monomers resin combinations dissolved in water / solvent. Although the inclusion of hydrophilic monomers has achieved high immediate adhesion forces, studies have shown that dentin-resin interface have become much weaker over time. In this study, bond strength of four adhesive systems was evaluated bymicrotensile test and quantitative analyze ofthe hybrid layer was obtained by micro-Raman spectroscopy. For microtensile test, the factors of variation were 2: the type of adhesive (AdperScotchbondMulti-Purpose, AdperSingle Bond 2, Adper SE Plus, AdperEasy One), and the period of storage at 3 levels (1 day, 30 days, 180 days), totaling 12 levels of variation. The experimental units were made on 120 dentin surfaces of intact humanunerupted third molars (n = 10). The parametric analysis of variance ANOVA and multiple comparison Games Howell was used for statistical analysis. For micro-Raman spectroscopy were used three teeth for each adhesive system, with a total of 12 teeth (n = 3). Raman spectra of the samples were recorded on a Micro-Raman spectrometer RENISHAW invia with 785 nm excitation (laser diode, RENISHAW) coupled to a microscope LEICA DM2500M with motorized stage (x, y, z) RENISHAW MS 20 EncodedStage with lateral and axial resolutionof 100 nm and 1 microns. Etch-and-rinse adhesives ScotchbondMulti-Purposeand SingleBond of this study showed the highest bond strength values, with values within a range from 44.36 to 50.66 MPa, whereas the self-etch adhesives SE Plusand Easy One had values of 17.97 to 24.60 MPa. The adhesive that showed the highest bond strength was ScotchbondMulti-Purpose and the worst performance was fromEasy One.All adhesives showed a significant decrease in bond strength after 30 and 180 days. In micro-Raman analysis, the ScotchbondMulti-Purpose was more homogeneous and had penetration values similar to those of the adhesive Single Bond and Easy One. The SE Plus had the lowest penetration of the adhesive and the thinner hybrid layer. We conclude that evaluating 4 different types of adhesives of the same brand, there is a negative relationship between the strategies of adhesion (decreasing the number of steps and bottles) and bond strength and quality of the hybrid layer.
5

Resistência de união de uma resina composta à dentina normal e erodida: o papel da aplicação de soluções de clorexidina em diferentes concentrações após seis meses e um ano de envelhecimento / Bond strength of a composite resin to normal and eroded dentin: the role of the application of chlorhexidine solutions in different concentrations after sixmonths and one-year of aging

Francisconi, Luciana Fávaro 10 August 2012 (has links)
A aplicação de soluções de digluconato de clorexidina (CHX), em diferentes concentrações, tem demonstrado potencial em prevenir a progressão da erosão dentinária in situ e a diminuição, com o passar do tempo, dos valores de resistência de união (RU) de resinas compostas (RC) à dentina normal ou afetada por cárie. Entretanto, seu papel na adesão à dentina já erodida é desconhecido. Este estudo se propôs, portanto, a avaliar o efeito da aplicação de soluções de CHX em diferentes concentrações na RU de uma RC à dentina normal (parâmetro para comparações) e à dentina erodida, ao longo do tempo. Terceiros molares humanos hígidos extraídos (n=48) tiveram seu terço oclusal seccionado e as superfícies dentinárias expostas foram somente submetidas à ação de uma lixa de carbeto de silício de granulação 600/1 min (dentina normal-N, n=24), ou subsequentemente erodidas por um refrigerante a base de cola (imersões de 5 min, 3x/dia, 5 dias; dentina erodida-E, n=24). Foram, então, condicionadas (H3PO4 a 37%; 15 s), lavadas, secas e reidratadas com 1,5 L, respectivamente, de água deionizada (controle-NC, n=8 / EC, n=8), de CHX a 0,004% (N0,004%, n=8 / E0,004%, n=8) ou de CHX a 2% (N2%, n=8 / E2%, n=8). O sistema adesivo AdperTMSingle Bond 2® foi aplicado em todos os espécimes e a porção coronária foi incrementalmente reconstruída com a RC FiltekTMZ350®. Depois de armazenados em água deionizada (24 h, 37oC), os espécimes foram seccionados em palitos (secção transversal 0,81 mm2), que foram testados, sob força de tração (EMIC; célula de carga de 50 kgf; 0,5 mm/minuto), imediatamente ou depois de 6 meses ou 1 ano de envelhecimento. As falhas foram analisadas e classificadas em adesivas, mistas, coesivas em dentina ou em resina. Paralelamente, avaliou-se a qualidade da hibridização para cada grupo experimental, por meio da obtenção de imagens em microscopia confocal de varredura a laser de um espécime por grupo, hibridizado pelo mesmo adesivo, mas marcado pela adição de rodamina B, e seccionado apenas no sentido mésio-distal. Os dados obtidos da microtração foram analisados por meio dos testes de ANOVA a três critérios e de Tukey (p<0,05). Os valores médios de RU (MPa±dp; imediatamente / 6 meses / 1 ano) foram: NC (34,74±9,79 / 20,77±14,35 / 7,58±4,94); N0,004% (35,69±9,85 / 23,10±8,13 / 13,82±10,12); N2% (41,22±5,38 / 34,64±6,62 / 13,25±4,83); EC (20,94±5,37 / 7,87±8,81 / 5,43±4,99); E0,004% (22,12±7,44 / 3,47±6,25 / 4,97±3,11); E2% (15,97±5,17 / 22,23±9,12 / 5,41±5,47). Falhas adesivas e/ou mistas consistiram-se nas preponderantemente observadas. Os valores de RU da RC à dentina erodida foram sempre inferiores àqueles da RC à dentina normal. Tais valores, para ambas as condições de dentina, experimentaram redução significante com o passar do tempo, mas a aplicação da solução de CHX a 2% foi capaz de mantê-los estáveis até os 6 meses de envelhecimento dos espécimes. Portanto, a aplicação de soluções de CHX, a 2%, apresenta-se como uma estratégia promissora para conservar a RU de resinas compostas tanto à dentina normal quanto à dentina erodida. Com o tempo, no entanto, seu efeito pode tornar-se reduzido ou irrelevante. / The application of chlorhexidine digluconate (CHX) solutions, in different concentrations, has shown potential in preventing the progression of dentin erosion in situ and the decline, in the course of time, of the bond strength (BS) values of composite resins (CR) to normal or caries-affected dentin. However, its role on adhesion to already eroded dentin is unknown. This study aimed, therefore, to evaluate the effect of the application of CHX solutions in different concentrations on BS of a CR to normal (parameter for comparisons) and to eroded dentin over time. Extracted sound human third molars (n=48) had their occlusal thirds sectioned and exposed flat dentin was only submitted to a 600-grit SiC paper/1min (normal dentin- N, n=24), or subsequently eroded by a regular-cola soft-drink (5-min immersions, 3x/day, 5 days; eroded dentin-E, n=24). They were, then, acid-etched (37% H3PO4; 15 s), washed, vigorously dried, and rehydrated with 1.5 L, respectively, of deionized water (control-NC, n=8 / EC, n=8); of 0.004% CHX (N0.004%, n=8 / E0.004%, n=8); or of 2% CHX (N2%, n=8 / E2%, n=8). AdperTMSingle Bond 2® was applied in all specimens and composite core buildups were incrementally constructed with FiltekTMZ350®. After storage in deionized water (24 h, 37°C), specimens were sectioned in beams (cross-section 0.81 mm2), which were tested, under tensile (EMIC; 50 kgf load cell; 0.5 mm/minute), immediately or after 6 months or 1 year of aging. Failures were analyzed and classified in adhesive, mixed, cohesive in dentin or in resin. In parallel, the quality of the hybridization for each experimental group was evaluated, by means of the obtainment of laser scanning confocal microscopy images from one specimen per group, hybridized with the same adhesive, but marked by the addition of rhodamine B and sectioned only mesiodistally. Microtensile data were analyzed by three-way ANOVA and Tukey tests (<0.05). Mean TBS values (MPa±sd; immediately / 6 months / 1 year) were: NC (34,74±9,79 / 20,77±14,35 / 7,58±4,94); N0,004% (35,69±9,85 / 23,10±8,13 / 13,82±10,12); N2% (41,22±5,38 / 34,64±6,62 / 13,25±4,83); EC (20,94±5,37 / 7,87±8,81 / 5,43±4,99); E0,004% (22,12±7,44 / 3,47±6,25 / 4,97±3,11); E2% (15,97±5,17 / 22,23±9,12 / 5,41±5,47). Adhesive and/or mixed failures consisted in the mainly observed ones. BS values of the CR to the eroded dentin were always lower than that of the CR to the normal dentin. These values, to both dentin conditions, experienced a significant reduction in the course of time, but application of the 2% CHX solution was able to keep them stable until 6-months aging of the specimens. Therefore, the application of CHX solutions, at 2%, is presented as a promising strategy to conserve BS both to normal and to eroded dentin. Over time, however, its effect may become reduced or irrelevant.
6

Análise do efeito de substâncias liberadas por adesivos dentinários sobre a atividade e a expressão gênica de proteases da matriz extracelular (MMPs e CTs) em células-tronco da polpa dentária humana / Analysis of the effects of substances leached from adhesive systems on the activity and gene expression of extracellular matrix proteases (MMPs e CTs) in human dental pulp stem cells

Souza-Rodrigues, Renata Duarte de 05 December 2014 (has links)
Adesivos dentinários aplicados diretamente sobre dentina aumentam a atividade de enzimas endógenas deste tecido que degradam colágeno, colocando em risco a integridade da camada híbrida de restaurações estéticas. Estes adesivos podem também alcançar a polpa dentária indiretamente através do fluído dos túbulos dentinários por substâncias liberadas pelos mesmos. Desta forma, a polpa dentária poderia responder a estas substâncias por meio de síntese e/ou aumento da atividade de colagenases, o que poderia colaborar na degradação da camada híbrida. Sendo assim, o objetivo desse trabalho foi avaliar o efeito das substâncias liberadas por sistemas adesivos dos tipos autocondicionante e condicione e lave sobre a atividade e a expressão gênica de metaloproteinases (MMPs) e cisteíno-catepsinas (CTs) em células-tronco da polpa dentária humana. Foram aplicados meios de cultura condicionados por adesivos do tipo autocondicionante e condicione e lave polimerizados e não polimerizados sobre culturas celulares por 24 horas. O meio de cultivo fresco foi usado como controle. Depois de 24, 48, 72 e 96 horas, as atividades gelatinolíticas de MMP-2 e de MMP-9 foram avaliadas por meio da técnica de zimografia em gel de gelatina. Nos mesmos tempos experimentais, a modulação da expressão gênica das MMPs (1, 2, 3, 7, 9, 13 e 14) e das CTs (B e K) foi analisada por meio de reação de transcriptase reversa quantitativa em tempo real (qRT-PCR). Os resultados obtidos dos dois experimentos foram avaliados por meio do teste estatístico ANOVA, complementado pelo teste de Tukey (p<0.05). Todos os grupos mostraram atividade gelatinolítica aumentada de MMP-2 e MMP-9. Até 72 horas, as atividades foram similares em todos os grupos experimentais. Diferenças significativas apareceram somente em 96 horas. De forma geral, as maiores atividades de MMPs foram observadas nas culturas celulares tratadas com o adesivo autocondicionante. Para a MMP-2, o grupo do adesivo autocondicionante polimerizado mostrou atividade intermediária, enquanto o grupo não polimerizado mostrou a maior atividade. Os dois grupos do adesivo condicione e lave polimerizado e não polimerizado mostraram atividade de MMP-9 intermediária, enquanto o grupo autocondicionante polimerizado mostrou maior atividade que o grupo controle. O qRT-PCR revelou que a maioria das MMPs e CTs analisadas tiveram a expressão gênica positivamente modulada em 24 e 48 horas. MMP-7 e MMP-9 não foram expressos em nenhum grupo experimental. Baseados nas limitações deste estudo in vitro, concluímos que substâncias liberadas por sistemas adesivos são capazes de influenciar células-tronco de polpa dentária humana levando ao aumento da atividade de MMP-2 e MMP-9 e também à modulação positiva de genes das MMPs e CTS estudadas. / Adhesive systems directly applied to dentin increase the activity of endogenous collagen degrading proteinases of the dentin, which jeopardizes the integrity of the hybrid layer of aesthetic restorations. These adhesives can also reach the dental pulp through the dentinal fluid indirectly by substances leached from them. Then, the dental pulp tissue could respond by synthetizing and/or increasing the activity of collagen proteases, which in turn could collaborate to the hybrid layer degradation. Then, the aim of this study was to evaluate the effect of substances leached from self-etch and etch-and-rinse adhesive systems on the expression and activities of matrix metalloproteinases (MMPs) and cysteine cathepsins (CT-B and CT-K) in human dental pulp stem cells. Culture media conditioned by polymerized or non-polymerized self-etch and etch-and-rinse adhesive systems were applied to the cultures for 24 hours. Fresh medium was used as control. After 24, 48, 72 and 96 hours, the gelatinolytic activities of MMP-2 and MMP-9 were assessed by zymography technique. At the same experimental time gene expression of MMPs (1, 2, 3, 7, 9, 13 e 14) and CTs (B e K) were analyzed with quantitative reverse transcription polymerase chain reaction (qRT-PCR). Data was compared by ANOVA complemented by the Tukey´s test (p<0.05). All experimental groups showed increased gelatinolytic activity for MMP-2 and MMP-9. Until 72 hours, the activities were similar regardless the group. Significant differences appeared only after 96 hours. Overall, the highest activities of MMPs were observed in the cultures treated with the self-etch adhesive. For MMP-2, the group of polymerized self-etch adhesive showed intermediary activity, while the group of non-polymerized adhesive showed the highest activity. Both polymerized and non-polymerized etch-and-rinse adhesive groups showed intermediary MMP-9 activity, while the group of polymerized self-etch adhesive showed higher activity than control. The qRT-PCR revealed that most of MMPs and CTs analyzed presented the gene expression positively modulated at 24 and 48 hours. MMP-7 and MMP-9 were not expressed in any experimental group.Based on the limitations of this in vitro study, it was concluded that substances leached from adhesive systems are able to influence human dental pulp stem cells leading to the increase of the activity of MMP-2 and MMP-9 along with positive modulation of MMPs and CTS studied genes.
7

Interaction between dentin bonding agents and dentin: from in situ proteolytic activity to mechanical test / A interação de agentes adesivos à dentina: da ação proteolítica in situ aos testes mecânicos de adesão

Giacomini, Marina Ciccone 22 March 2019 (has links)
The use of the versatile universal adhesive systems aims to improve adhesion to dentin and simplify the bonding procedure. The association between functional monomer as 10-methacryloyloxydecyl-dihydrogen phosphate (10-MDP) and proteolytic inhibitors seems to be a promising strategy to improve the longevity of hybrid layer. Therefore, this study aimed to evaluate the performance of Adper Single Bond Universal (SU) combined with proteolytic inhibitors, especially chlorhexidine (CHX), in different dentin substrates overtime. In article 1, the interaction between CHX and E-64 with SU (in etch-and-rinse mode) was investigated in sound, artificial carious and eroded dentin over 18 months aging. It was found that carious substrate was the most affected and none of the inhibitors tested were able to maintain stability over 18 months. Furthermore, it was observed that CHX negatively impacted regardless of the substrate, leading to the hypothesis of possible competition between CHX and 10-MDP, since both involve calcium ions in their mechanism of action. For a better comprehension, article 2 purposed the evaluation of proteolytic activity and bonding to dentin tests, focusing on the performance of SU in both modes (etch-and-rinse and self-etching) compared to a conventional MDP-free 2- step adhesive system (Adper Single Bond 2), associated with CHX over 6 months aging. It was observed that proteolytic activity was evidenced when all dentin bonding systems (DBS) was used. SU in self-etching mode showed the highest values of microtensile bond strength. CHX was able to reduce proteolytic activity, regardless of DBS even in 6 months aging. Moreover, CHX did not affect negatively mechanical properties. In conclusion, CHX is capable of reduce proteolytic activity, however it did not provide long lasting up to 18 months. / A utilização dos versáteis sistemas adesivos universais tem por objetivo melhorar à adesão à dentina e simplificar o procedimento adesivo. A associação entre monômeros funcionais como o 10-Metacriloiloxidecil dihidrogênio fosfato (10-MDP) e inibidores proteolíticos tende a ser uma estratégia promissora para melhorar a longevidade da camada hibrida. Desta forma, este trabalho tem por objetivo avaliar o desempenho do Adper Single Bond Universal (SU) combinado com inibidores proteolíticos, especialmente a clorexidina (CHX), em diferentes substratos dentinários ao longo do tempo. No artigo 1, a interação entre CHX e E-64 com SU (modo convencional) foi investigada em dentina sadia, artificialmente cariada e erodida em 18 meses de envelhecimento. Foi encontrado que o substrato cariado foi o mais afetado e nenhum dos inibidores testados foram capazes de manter a estabilidade ao longo de 18 meses. Além do mais, observou-se que a CHX impactou de forma negativa independente do substrato avaliado, levando a hipótese de uma possível competição entre ela e o 10-MDP, visto que ambos envolvem íons Ca em seus mecanismos de ação. Para uma melhor compreensão, no artigo 2 foi proposto testes para avaliação de atividade proteolítica e resistência de união à dentina, com foco no desempenho do SU nos dois modos (convencional e autocondicionantes) comparado a um convencional de 2 passos livre de MDP (Adper Single Bond 2), associados com CHX em 6 meses de envelhecimento. Foi observado que a atividade proteolítica foi evidente em todos os sistemas adesivos (SA). O SU no modo autocondicionantes apresentou os maiores valores de resistência de união. A CHX foi capaz de reduzir a atividade proteolítica, independente dos SA mesmo em 6 meses de envelhecimento. Além disso, a CHX não afetou negativamente as propriedades mecânicas. A CHX é capaz de reduzir a atividade proteolítica, no entanto não perdura até 18 meses.
8

EFEITO DA CLOREXEDINA ÁCIDA NA RESISTÊNCIA DE UNIÃO IMEDIATA E EM LONGO PRAZO DE SISTEMAS ADESIVOS ATUAIS

Müller, Clecila 28 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As metaloproteinases de matriz (MMPs) têm sido extensivamente estudadas, e inibidores de MMP têm sido utilizados como agentes de pré-tratamento dental previamente procedimentos adesivos em dentina porque reduzem a degradação do colagénio e melhoraram a resistência de união, sendo o inibidor mais utilizado a clorexidina (CHX). O objetivo deste estudo foi analisar o efeito de diferentes valores de pH da CHX na resistência de união de um adesivo universal e um adesivo autocondicionante, imediatamente e após 12 meses de envelhecimen-to. Métodos: superfícies planas de dentina de setenta e dois molares humanos devidamente preparados para o estudo foram divididos aleatoriamente em 12 grupos de acordo com super-fícies pré-tratados com CHX com diferentes valores de pH (CHX 5.8 ou CHX 2,9) aplicadas durante 60 s, antes do antes da aplicação doadesivo e abordagem de união (Scotchbond Uni-versal: nas estratégias autocondicionante e condicionamento ácido total) ou um adesivo auto-condicionante (Clearfil SE bond). Restaurações de resina composta foram construídas incre-mentalmente. Os grupos foram examinados no imediatamente e após 12 meses de armazena-mento de água, palitos com área de secção transversal de 0,8 mm² foram testados para resis-tência de união (μTBS). Dois palitos de cada dente foram selecionados a fim de avaliação em MEV. As médias de μTBS foram analisadas separadamente para cada sistema adesivo usando one-way ANOVA e teste de Tukey (α = 0,05). Resultados: Os dados mostraram que CHX 5,8 e 2,9 CHX não têm diferenças estatísticas cedo, enquanto CHX 2.9 na longo prazo, preserva a resistência de união. O substrato tratado com CHX 2,9 preservada a resistência de ligação em todos os sistemas adesivos em contraste com os grupos de auto-adesivas etch tratados com CHX 5,8 a longo prazo. Conclusões: O tratamento com clorexidina baixo pH preservar a re-sistência de união de restaurações adesivas no longo prazo em todos adesivo significado stra-tegies.Clinical: O estudo pode ajudar a prever o desempenho clínico de sistemas adesivos de forma mais eficaz no longo prazo reduzindo o pH do pré-tratamento solução de CHX.
9

Análise do efeito de substâncias liberadas por adesivos dentinários sobre a atividade e a expressão gênica de proteases da matriz extracelular (MMPs e CTs) em células-tronco da polpa dentária humana / Analysis of the effects of substances leached from adhesive systems on the activity and gene expression of extracellular matrix proteases (MMPs e CTs) in human dental pulp stem cells

Renata Duarte de Souza-Rodrigues 05 December 2014 (has links)
Adesivos dentinários aplicados diretamente sobre dentina aumentam a atividade de enzimas endógenas deste tecido que degradam colágeno, colocando em risco a integridade da camada híbrida de restaurações estéticas. Estes adesivos podem também alcançar a polpa dentária indiretamente através do fluído dos túbulos dentinários por substâncias liberadas pelos mesmos. Desta forma, a polpa dentária poderia responder a estas substâncias por meio de síntese e/ou aumento da atividade de colagenases, o que poderia colaborar na degradação da camada híbrida. Sendo assim, o objetivo desse trabalho foi avaliar o efeito das substâncias liberadas por sistemas adesivos dos tipos autocondicionante e condicione e lave sobre a atividade e a expressão gênica de metaloproteinases (MMPs) e cisteíno-catepsinas (CTs) em células-tronco da polpa dentária humana. Foram aplicados meios de cultura condicionados por adesivos do tipo autocondicionante e condicione e lave polimerizados e não polimerizados sobre culturas celulares por 24 horas. O meio de cultivo fresco foi usado como controle. Depois de 24, 48, 72 e 96 horas, as atividades gelatinolíticas de MMP-2 e de MMP-9 foram avaliadas por meio da técnica de zimografia em gel de gelatina. Nos mesmos tempos experimentais, a modulação da expressão gênica das MMPs (1, 2, 3, 7, 9, 13 e 14) e das CTs (B e K) foi analisada por meio de reação de transcriptase reversa quantitativa em tempo real (qRT-PCR). Os resultados obtidos dos dois experimentos foram avaliados por meio do teste estatístico ANOVA, complementado pelo teste de Tukey (p<0.05). Todos os grupos mostraram atividade gelatinolítica aumentada de MMP-2 e MMP-9. Até 72 horas, as atividades foram similares em todos os grupos experimentais. Diferenças significativas apareceram somente em 96 horas. De forma geral, as maiores atividades de MMPs foram observadas nas culturas celulares tratadas com o adesivo autocondicionante. Para a MMP-2, o grupo do adesivo autocondicionante polimerizado mostrou atividade intermediária, enquanto o grupo não polimerizado mostrou a maior atividade. Os dois grupos do adesivo condicione e lave polimerizado e não polimerizado mostraram atividade de MMP-9 intermediária, enquanto o grupo autocondicionante polimerizado mostrou maior atividade que o grupo controle. O qRT-PCR revelou que a maioria das MMPs e CTs analisadas tiveram a expressão gênica positivamente modulada em 24 e 48 horas. MMP-7 e MMP-9 não foram expressos em nenhum grupo experimental. Baseados nas limitações deste estudo in vitro, concluímos que substâncias liberadas por sistemas adesivos são capazes de influenciar células-tronco de polpa dentária humana levando ao aumento da atividade de MMP-2 e MMP-9 e também à modulação positiva de genes das MMPs e CTS estudadas. / Adhesive systems directly applied to dentin increase the activity of endogenous collagen degrading proteinases of the dentin, which jeopardizes the integrity of the hybrid layer of aesthetic restorations. These adhesives can also reach the dental pulp through the dentinal fluid indirectly by substances leached from them. Then, the dental pulp tissue could respond by synthetizing and/or increasing the activity of collagen proteases, which in turn could collaborate to the hybrid layer degradation. Then, the aim of this study was to evaluate the effect of substances leached from self-etch and etch-and-rinse adhesive systems on the expression and activities of matrix metalloproteinases (MMPs) and cysteine cathepsins (CT-B and CT-K) in human dental pulp stem cells. Culture media conditioned by polymerized or non-polymerized self-etch and etch-and-rinse adhesive systems were applied to the cultures for 24 hours. Fresh medium was used as control. After 24, 48, 72 and 96 hours, the gelatinolytic activities of MMP-2 and MMP-9 were assessed by zymography technique. At the same experimental time gene expression of MMPs (1, 2, 3, 7, 9, 13 e 14) and CTs (B e K) were analyzed with quantitative reverse transcription polymerase chain reaction (qRT-PCR). Data was compared by ANOVA complemented by the Tukey´s test (p<0.05). All experimental groups showed increased gelatinolytic activity for MMP-2 and MMP-9. Until 72 hours, the activities were similar regardless the group. Significant differences appeared only after 96 hours. Overall, the highest activities of MMPs were observed in the cultures treated with the self-etch adhesive. For MMP-2, the group of polymerized self-etch adhesive showed intermediary activity, while the group of non-polymerized adhesive showed the highest activity. Both polymerized and non-polymerized etch-and-rinse adhesive groups showed intermediary MMP-9 activity, while the group of polymerized self-etch adhesive showed higher activity than control. The qRT-PCR revealed that most of MMPs and CTs analyzed presented the gene expression positively modulated at 24 and 48 hours. MMP-7 and MMP-9 were not expressed in any experimental group.Based on the limitations of this in vitro study, it was concluded that substances leached from adhesive systems are able to influence human dental pulp stem cells leading to the increase of the activity of MMP-2 and MMP-9 along with positive modulation of MMPs and CTS studied genes.
10

Resistência de união de uma resina composta à dentina normal e erodida: o papel da aplicação de soluções de clorexidina em diferentes concentrações após seis meses e um ano de envelhecimento / Bond strength of a composite resin to normal and eroded dentin: the role of the application of chlorhexidine solutions in different concentrations after sixmonths and one-year of aging

Luciana Fávaro Francisconi 10 August 2012 (has links)
A aplicação de soluções de digluconato de clorexidina (CHX), em diferentes concentrações, tem demonstrado potencial em prevenir a progressão da erosão dentinária in situ e a diminuição, com o passar do tempo, dos valores de resistência de união (RU) de resinas compostas (RC) à dentina normal ou afetada por cárie. Entretanto, seu papel na adesão à dentina já erodida é desconhecido. Este estudo se propôs, portanto, a avaliar o efeito da aplicação de soluções de CHX em diferentes concentrações na RU de uma RC à dentina normal (parâmetro para comparações) e à dentina erodida, ao longo do tempo. Terceiros molares humanos hígidos extraídos (n=48) tiveram seu terço oclusal seccionado e as superfícies dentinárias expostas foram somente submetidas à ação de uma lixa de carbeto de silício de granulação 600/1 min (dentina normal-N, n=24), ou subsequentemente erodidas por um refrigerante a base de cola (imersões de 5 min, 3x/dia, 5 dias; dentina erodida-E, n=24). Foram, então, condicionadas (H3PO4 a 37%; 15 s), lavadas, secas e reidratadas com 1,5 L, respectivamente, de água deionizada (controle-NC, n=8 / EC, n=8), de CHX a 0,004% (N0,004%, n=8 / E0,004%, n=8) ou de CHX a 2% (N2%, n=8 / E2%, n=8). O sistema adesivo AdperTMSingle Bond 2® foi aplicado em todos os espécimes e a porção coronária foi incrementalmente reconstruída com a RC FiltekTMZ350®. Depois de armazenados em água deionizada (24 h, 37oC), os espécimes foram seccionados em palitos (secção transversal 0,81 mm2), que foram testados, sob força de tração (EMIC; célula de carga de 50 kgf; 0,5 mm/minuto), imediatamente ou depois de 6 meses ou 1 ano de envelhecimento. As falhas foram analisadas e classificadas em adesivas, mistas, coesivas em dentina ou em resina. Paralelamente, avaliou-se a qualidade da hibridização para cada grupo experimental, por meio da obtenção de imagens em microscopia confocal de varredura a laser de um espécime por grupo, hibridizado pelo mesmo adesivo, mas marcado pela adição de rodamina B, e seccionado apenas no sentido mésio-distal. Os dados obtidos da microtração foram analisados por meio dos testes de ANOVA a três critérios e de Tukey (p<0,05). Os valores médios de RU (MPa±dp; imediatamente / 6 meses / 1 ano) foram: NC (34,74±9,79 / 20,77±14,35 / 7,58±4,94); N0,004% (35,69±9,85 / 23,10±8,13 / 13,82±10,12); N2% (41,22±5,38 / 34,64±6,62 / 13,25±4,83); EC (20,94±5,37 / 7,87±8,81 / 5,43±4,99); E0,004% (22,12±7,44 / 3,47±6,25 / 4,97±3,11); E2% (15,97±5,17 / 22,23±9,12 / 5,41±5,47). Falhas adesivas e/ou mistas consistiram-se nas preponderantemente observadas. Os valores de RU da RC à dentina erodida foram sempre inferiores àqueles da RC à dentina normal. Tais valores, para ambas as condições de dentina, experimentaram redução significante com o passar do tempo, mas a aplicação da solução de CHX a 2% foi capaz de mantê-los estáveis até os 6 meses de envelhecimento dos espécimes. Portanto, a aplicação de soluções de CHX, a 2%, apresenta-se como uma estratégia promissora para conservar a RU de resinas compostas tanto à dentina normal quanto à dentina erodida. Com o tempo, no entanto, seu efeito pode tornar-se reduzido ou irrelevante. / The application of chlorhexidine digluconate (CHX) solutions, in different concentrations, has shown potential in preventing the progression of dentin erosion in situ and the decline, in the course of time, of the bond strength (BS) values of composite resins (CR) to normal or caries-affected dentin. However, its role on adhesion to already eroded dentin is unknown. This study aimed, therefore, to evaluate the effect of the application of CHX solutions in different concentrations on BS of a CR to normal (parameter for comparisons) and to eroded dentin over time. Extracted sound human third molars (n=48) had their occlusal thirds sectioned and exposed flat dentin was only submitted to a 600-grit SiC paper/1min (normal dentin- N, n=24), or subsequently eroded by a regular-cola soft-drink (5-min immersions, 3x/day, 5 days; eroded dentin-E, n=24). They were, then, acid-etched (37% H3PO4; 15 s), washed, vigorously dried, and rehydrated with 1.5 L, respectively, of deionized water (control-NC, n=8 / EC, n=8); of 0.004% CHX (N0.004%, n=8 / E0.004%, n=8); or of 2% CHX (N2%, n=8 / E2%, n=8). AdperTMSingle Bond 2® was applied in all specimens and composite core buildups were incrementally constructed with FiltekTMZ350®. After storage in deionized water (24 h, 37°C), specimens were sectioned in beams (cross-section 0.81 mm2), which were tested, under tensile (EMIC; 50 kgf load cell; 0.5 mm/minute), immediately or after 6 months or 1 year of aging. Failures were analyzed and classified in adhesive, mixed, cohesive in dentin or in resin. In parallel, the quality of the hybridization for each experimental group was evaluated, by means of the obtainment of laser scanning confocal microscopy images from one specimen per group, hybridized with the same adhesive, but marked by the addition of rhodamine B and sectioned only mesiodistally. Microtensile data were analyzed by three-way ANOVA and Tukey tests (<0.05). Mean TBS values (MPa±sd; immediately / 6 months / 1 year) were: NC (34,74±9,79 / 20,77±14,35 / 7,58±4,94); N0,004% (35,69±9,85 / 23,10±8,13 / 13,82±10,12); N2% (41,22±5,38 / 34,64±6,62 / 13,25±4,83); EC (20,94±5,37 / 7,87±8,81 / 5,43±4,99); E0,004% (22,12±7,44 / 3,47±6,25 / 4,97±3,11); E2% (15,97±5,17 / 22,23±9,12 / 5,41±5,47). Adhesive and/or mixed failures consisted in the mainly observed ones. BS values of the CR to the eroded dentin were always lower than that of the CR to the normal dentin. These values, to both dentin conditions, experienced a significant reduction in the course of time, but application of the 2% CHX solution was able to keep them stable until 6-months aging of the specimens. Therefore, the application of CHX solutions, at 2%, is presented as a promising strategy to conserve BS both to normal and to eroded dentin. Over time, however, its effect may become reduced or irrelevant.

Page generated in 0.4298 seconds