• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 6
  • 6
  • 6
  • 6
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 45
  • 22
  • 18
  • 14
  • 13
  • 10
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise teórico-experimental de condensadores arame sobre tubo sob convecção forçada para refrigeradores domésticos

Sigwalt, Rodrigo Alexandre 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T07:49:09Z (GMT). No. of bitstreams: 1 277405.pdf: 2309735 bytes, checksum: e0d4ecbb633fc80b58eaa7e4ab08f15c (MD5) / O desenvolvimento de trocadores de calor compactos para aplicações em refrigeração doméstica tem sido o foco de diversos estudos, isso devido ao seu impacto na redução de custos e de consumo de energia, além de um melhor aproveitamento do espaço ocupado pelos componentes dos sistemas de refrigeração. Este espaço deve ser reduzido ao máximo para permitir um aumento do volume útil de armazenamento do refrigerador sem alterar as dimensões externas do produto. Devido ao seu baixo custo de manufatura, condensadores arame sobre tubo continuam como a opção mais vantajosa para a refrigeração doméstica. Tradicionalmente, tais trocadores de calor são projetados para operar sob convecção natural. No entanto, para altas capacidades de refrigeração, os benefícios da maior compacidade dos condensadores de convecção forçada acabam por superar o ônus do bombeamento do ar externo pelo trocador. Realizou-se inicialmente neste trabalho uma busca na literatura por configurações compactas de trocadores arame sobre tubo para posterior avaliação de seu desempenho termo-hidráulico. A configuração escolhida para análise (Ohgaki, 2002) foi aquela dotada da maior área de troca térmica por unidade de volume ocupado. Nela foram identificadas as principais características geométricas (número de passes de tubo e espaçamentos radial, entre arames e longitudinal), cujo efeito sobre o desempenho termo-hidráulico foi avaliado por meio da construção e teste de dezesseis protótipos. Um calorímetro de túnel de vento de circuito aberto foi projetado e construído, e medições de condutância térmica e de queda de pressão no lado do ar foram realizadas para valores típicos de vazão de ar encontrados em condensadores de convecção forçada. Os dados foram correlacionados em função de parâmetros adimensionais, como o fator j de Colburn e o fator de atrito de Fanning. Os coeficientes das correlações foram regredidos a partir das características geométricas com base no método proposto por Montgomery (2001). A regressão mostrou uma boa concordância com os dados experimentais, com erros máximos de 9,4% para a transferência de calor e 14,2% para a queda de pressão. Finalmente, uma análise quantitativa para a seleção da configuração mais viável do ponto de vista da aplicação é discutida. / The development of compact heat exchangers for domestic refrigeration applications has been the focus of several studies thanks to its impact in reducing material costs and energy consumption. It also allows for a more effective usage of the space occupied by the cooling system components, which increases the net storage volume of the refrigerator without changing the external dimensions of the product. Due to its low manufacturing cost, wire-on-tube heat exchangers are still the most advantageous condenser type for household refrigeration applications where, traditionally, natural convection is the dominant heat transfer mode. However, for high cooling capacity applications, the potential benefits of more compact forced convection wire-on-tube condensers illustrated above seem to overcome the costs and energy consumption involved in pumping the external air through the condenser. The starting point of the present work was a literature search for compact wire-on-tube heat exchanger configurations which would be subsequently evaluated on the basis of its thermal-hydraulic performance. The configuration chosen for a more in-depth analysis (Ohgaki, 2002) was the one with the largest heat transfer area per unit volume. The main geometric parameters were identified, namely, the number of tube passes, the radial, longitudinal and wire spacings, and their effect on the thermal-hydraulic performance has been assessed by means of the construction and testing of sixteen prototypes. An open-loop wind-tunnel calorimeter was designed and built, and measurements of thermal conductance and pressure drop on the air side were carried ou for values of air flow rate typical of those found in forced convection condensers. The data were correlated in terms of dimensionless parameters like the Colburn j-factor and the Fanning friction factor. The coefficients of the correlations were regressed based on the geometric parameters using the method proposed by Montgomery (2001). The agreement with the experimental data presented maximum errors of 9.4% for the heat transfer and 14.2% for the pressure drop. Finally, a quantitative analysis to provide the most viable configuration from the point of view of the application is discussed.
2

Síntese e caracterização de pseudocapacitores de aerogéis de Ni(OH)2 incorporados com polipirrol

Scarabelot, Letícia Toreti January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T05:04:49Z (GMT). No. of bitstreams: 1 340512.pdf: 1963134 bytes, checksum: 89f8b5b2f65809faa859a02a247a8308 (MD5) Previous issue date: 2016 / O desenvolvimento de dispositivos de armazenamento de energia proporciona muitas vantagens para aplicações portáteis. Resistentes e estáveis, os supercapacitores são de suma importância para a tecnologia pois agregam características de alta densidade de potência e energia, vindas dos capacitores convencionais e das baterias, respectivamente. Neste trabalho foram desenvolvidos pseudocapacitores com eletrodos baseados em aerogéis de hidróxido de níquel (Ni(OH)2) e como polímero condutor, polipirrol (PPy). Utilizando eletrólito gel de PVA/H3PO4, sendo materiais de fácil síntese e maior disponibilidade que apresentam efeito de pseudocapacitância. As propriedades físico-químicas e estruturais dos aerogéis foram analisadas através das técnicas de difração de raios X (DRX), espectroscopia de Raman, microscopia eletrônica de transmissão (TEM), termograviometria (TGA), área superficial (BET), volume e tamanho de poro (BJH), espectroscopia de absorção (UV-VIS) e condutividade elétrica.O dispositivo foi montado formando um sanduíche. O aerogel em forma de pó foi depositado em ambos os lados de um filme de PVA/H3PO4 (eletrólito/separador) e fecharam-se os contatos com cobre, obtendo-se um dispositivo completo com dois eletrodos, separador e eletrólito. Por meio da voltametria cíclica e carga/descarga, o desempenho dos pseudocapacitores foi avaliado, onde a capacitância específica, densidades de energia, densidade de potência e resistência em série foram determinadas.A capacitância específica apresentou aumento de 43 %, com a incorporação de PPy (276 F/g) e a resistência em série obtida apresentou a diminuição de 79 % (23,25 O/cm²). Resultados esses que refletem o melhor desempenho e melhores propriedades eletroquímicas dos dispositivos de aerogéis de Ni(OH)2 incorporados com PPy.<br> / Abstract: The development of energy storage devices provides many advantages for portable applications. Rugged and stable, supercapacitors are of utmost importance for that technology, for aggregating high power and energy density characteristics, coming from conventional capacitors and batteries, respectively.In this work, were developed pseudocapacitors with nickel hydroxide (Ni(OH)2) aerogel-based electrodes and a conductive polymer, polypyrrole (PPy). Using gel PVA/H3PO4 electrolyte, , which are easily synthesizable materials with greater availability, and exhibit pseudocapacitance effect. The structural and physical-chemical properties of the aerogels were analyzed through X-ray diffraction (DRX), Raman spectroscopy, transmission electronic microscopy (TEM), thermograviometry (TGA), specific surface area (BET), pore size and volume (BJH), absorption spectroscopy (UV-VIS) and electrical conductivity.The device was assembled a sandwich geometry. Powdered aerogel was deposited onto both sides of a PVA/H3PO4 film (electrolyte/separator) and the contacts were closed with copper, resulting on a complete device with two electrodes, separator and electrolyte. Through cyclic voltammetry and charge/discharge curves, the performance of the supercapacitors was devaluated, where the specific capacitance, power and energy densities and series resistance were determined.The specific capacitance was increased by 43% with the incorporation of the PPy (276 F/g) and the series resistance obtained decreased by 79% (23,25 O/cm²) which reflects the highest performance and the best electrochemical properties of Ni(OH)2 aerogels based devices incorporated with PPy.
3

Fonte de alta tensão para carga de capacidade

Soares, David Mendez, 1952- 15 July 2018 (has links)
Orientador: Arysio N. Santos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-15T13:46:58Z (GMT). No. of bitstreams: 1 Soares_DavidMendez_M.pdf: 1188689 bytes, checksum: b9798d70a6e6c593a9d08798f0c209cd (MD5) Previous issue date: 1979 / Resumo: O objetivo deste trabalho é a construção de uma fonte de alimentação para lasers pulsados de alta pressão, os quais requerem alta tensão e alta potência. É constituido de um circuito de carga para um banco de condensadores. A carga é feita através de um circuito duplicador Cockroft-Walton operando como limitador de corrente. A tensão sobre o banco de condensadores, sobe em degraus, sendo a voltagem de disparo desejada, controlada por uma chave no primário do transformador de alta tensão. As vantagens apresentadas por este sistema são: alta eficiência, possibilidade de suportar cargas de curto circuito, facilidade de construção e compacticidade. / Abstract: The purpose of this work is the construction of high pressure pulsed lasers power supply, which requires high voltage and high power. It is forrned by a charging circuit for a capacitor bank. The charging is done by a one-stage Cockroft-Walton circuit, operating as a current limiter. The voltage at the capacitor bank rises by steps. The desired voltage at firing is controlled by a switch at the primary of the high voltage transformer. The advantages of this set up are: high efficiency, possibility of standing short-circuits loads, easy construction and compacteness. / Mestrado / Mestre em Ciências
4

Analise dinamica de um volante supercritico para armazenamento de energia

Silva, Virgilio Mendonça da Costa e 17 February 1984 (has links)
Orientadores: Hans Ingo Weber, Jose Roberto de França Arruda / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-15T17:27:02Z (GMT). No. of bitstreams: 1 Silva_VirgilioMendoncadaCostae_M.pdf: 3704362 bytes, checksum: 57373d223113186f640285fe3c0b1395 (MD5) Previous issue date: 1984 / Resumo: Analisa-se dinamicamente um volante supercrítico para armazenamento de energia. Apresenta-se um modelo matemático do volante em sua estrutura de suporte, e analisa-se os movimentos 'whirling' livre e forçado, onde determina-se as velocidades críticas e amplitudes de vibração do volante. O volante tem formato anular preso por faixas a um cubo central. Desenvolveu-se também uma análise de estabilidade do sistema levando-se em consideração o amortecimento interno do material do eixo e das faixas do volante , e estuda-se a influência de um amortecimento esterno ao sistema, com a finalidade de aumentar suas regiões de estabilidade / Abstract: A supercritical flywheel for energy storage is analysed and its dynamiçal hehavior obtained. The mathematical model of an elastically supported flywheel is presented and free and forced whirling is investigated, to obtain critical velocities and amplitudes of vibration. The flywheel consists of a ring supported by spokes from the hub. A stability analysis is performed considering internal dlmping in the shaft and in the spokes and the stabilizing action for an external damper is investigated / Mestrado / Mestre em Engenharia Mecânica
5

Estudos de sinterização, oxidação anódica e desenvolvimento de um novo tipo de capacitor eletrolítico de NbTa

Gomes, Uilame Umbelino 31 July 1987 (has links)
Orientador: Daltro Garcia Pinatti / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-16T15:39:34Z (GMT). No. of bitstreams: 1 Gomes_UilameUmbelino_D.pdf: 7641002 bytes, checksum: f0f57d67ba34839df6264103adb3fe8f (MD5) Previous issue date: 1987 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Física / Doutor em Ciências
6

Análise experimental do desempenho termo-hidráulico de condensadores do tipo tubo-aletado

Weber, Gustavo Cardoso January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica. / Made available in DSpace on 2012-10-23T13:29:25Z (GMT). No. of bitstreams: 1 246748.pdf: 3135585 bytes, checksum: d35f0f43ee3b60b59492a549209f3a77 (MD5) / O objetivo deste trabalho é avaliar a performance termo-hidráulica de condensadores do tipo tubo-aletado. Para atingir tal objetivo uma bancada experimental foi construída e um código computacional foi desenvolvido. A bancada experimental consiste basicamente de dois circuitos: o de ar e o de fluido refrigerante, ambos permitindo a medição da taxa de calor dissipado pelo condensador. No circuito de ar mede-se a vazão de ar através de bocais convergentes, e a diferença de temperatura através de termopares diferenciais. No circuito de refrigerante mede-se a vazão de R134a através de um sensor tipo Coriolis e, calcula-se o diferencial de entalpia a partir de medições absolutas de pressão e temperatura. A partir dos dados experimentais de transferência de calor e de perda de carga do lado do ar calculam-se os parâmetros adimensionais j e f. Efeitos do processo de fabricação, espaçamento entre aletas, tipo de aleta, presença do louver, e tipo de borda foram explorados experimentalmente. Comparações com correlações disponíveis na literatura são apresentadas e discutidas. O código computacional desenvolvido pode ser utilizado tanto para calcular os valores de j e f com base nos dados experimentais, quanto para simular a taxa de dissipação de calor e a perda de carga a partir de correlações empíricas de j e f. O código computacional desenvolvido foi acoplado ao software de otimização MODEFRONTIER#, com o intuito de otimizar o espaçamento entre aletas de um condensador específico. The objective of this work is to evaluate the thermohydraulic performance of finned tube condensers. In order to accomplish this objective, a test bench was built and a computational code was developed. The test bench has two circuits: one for air flow and another for refrigerant flow. The condenser heat released rate can be measured in both circuits. In the air circuit, the air flow is measured by nozzles and the temperature difference by differential thermocouples. In the refrigerant circuit, the mass flow rate is measured by a Coriolis type mass flow meter and the enthalpy differential is calculated from the absolute temperature and pressure measurements. The j and the f dimensionless parameters are calculated from the experimental data. The effect of fin geometry, fin pitch, louver, and fin edge corrugation were all explored experimentally. Comparisons with correlations available in the open literature are presented and discussed. The computational code can be used either to calculate the j and the f parameters from heat transfer and air pressure drop data, or to simulate the heat transfer and the air pressure drop from j and f empirical correlations. The developed computational code was coupled to the MODEFRONTIER# optimization software in an attempt to optimize the fin pitch for a specific condenser.
7

Análise experimental do desempenho de condensadores do tipo arame-sobre-tubo

Arsego, Cleber January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica. / Made available in DSpace on 2012-10-21T01:46:25Z (GMT). No. of bitstreams: 0 / O desempenho global de um refrigerador doméstico depende do desempenho individual de cada um dos seus componentes. O condensador, responsável pela dissipação de calor para o meio ambiente, será o foco do presente trabalho. Mais especificamente, a atenção estará voltada para condensadores do tipo arame-sobre-tubo e com movimentação natural de ar, de larga aplicação no mercado brasileiro. Esse componente é geralmente tratado através de correlações empíricas, oriundas de trabalhos experimentais que empregam secções de testes que não refletem as suas reais condições de operação, tanto em termos da diferença de temperatura entre a sua superfície e o ar ambiente como em termos de confinamento. Nesse trabalho desenvolveu-se uma bancada experimental que possibilita a realização de testes com diferentes geometrias de condensadores e numa ampla faixa de condições de funcionamento. A bancada é composta por duas partes. Com a primeira controla-se e mede-se a vazão de água em circulação e a diferença da temperatura da água entre a entrada e saída do condensador. Com a segunda controla-se e mede-se a temperatura do ar em torno do trocador de calor. Uma seção de testes foi também especialmente desenvolvida. Essa seção reproduz fielmente as condições de realização de testes normalizados de refrigeradores e permite a variação da posição dos anteparos laterais, do trocador de calor e do refrigerador, com o intuito de identificar o impacto desses parâmetros sobre a taxa de dissipação de calor no condensador. Os resultados de testes, realizados com vários trocadores de calor submetidos a distintas condições de operação, foram correlacionados como função da geometria e da diferença de temperatura. Comparações com a correlação proposta por Tagliafico e Tanda (1997), obtidas com trocadores de calor não confinados, são também apresentadas e discutidas.
8

Condensação convectiva no interior de um perfil de alumínio tipo MPE contendo oito microcanais paralelos

Zanette, Guilherme Piazza January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2015 / Made available in DSpace on 2016-10-19T12:38:03Z (GMT). No. of bitstreams: 1 336490.pdf: 3989004 bytes, checksum: b86d0757001297a96642cc4ec5b0a4f3 (MD5) Previous issue date: 2015 / A condensação convectiva no interior de oito microcanais, com diâmetro hidráulico de 1,24 mm, contidos em um perfil comercial do tipo MPE (Multi Port Extruded) de alumínio foi estudada nesta dissertação. O fluido de trabalho empregado foi o R134a, e o modo de resfriamento foi obtido por meio de um sumidouro de calor constituído de um fluxo forçado de mistura de água e etileno glicol a temperaturas entre -6 e -12ºC. Um aspecto inovador neste aparato experimental foi a medição do fluxo de calor utilizando transdutores de fluxo de calor. Foram realizados testes monofásicos para a queda de pressão e transferência de calor a fim de validar o aparato experimental mediante a comparação dos resultados com os calculados com as correlações da literatura. Testes em condensação foram feitos com fluxos mássicos variando entre 154 e 308 kg/m²s, títulos variando entre 0,97 e 1, fluxos de calor entre 8,1 e 12,2 kW/m² e pressões entre 6,8 e 9,6 bar. De acordo com o mapa de padrões de Coleman e Garimella os pontos de operação testados indicaram os padrões anular-misto e anular. Os resultados experimentais comparados às correlações de Cavallini (2006) forneceram os menores desvios médios absolutos: 16,7% para a queda de pressão e 77,5% para o coeficiente de transferência de calor. <br> / Abstract : The convective condensation inside eight microchannels, with hydraulic diameter equal to 1,24 mm, contained in a profile type MPE (Multi Port Extruded) of aluminum was studied in this work. The working fluid used is R134a, and its cooling was made by a heat sink constituted by a water ethylenglicol mixture forced flow at temperatures between -6 and -12ºC. An innovative aspect in this experimental apparatus was the measurement of the heat flux using heat flux transducers. Single-phase tests for pressure drop and heat transfer were made in order to validate the experimental apparatus comparimg the data to the results from the classic literature correlations for single-phase flow. Tests on condensation were made with mass flows ranging from 154 to 308 kg / m²s , quality ranging from 0,97 to 1, heat flows between 8,1 to 12,2 kW / m² and pressures between 6,8 to 9,6 bar. Acording to the flow pattern map of Coleman and Garimella, the data points tested show annular-mist and annular flow patterns. The experimental results comparing with the correlations of Cavallini (2006) provided the least average deviations: 16.7% for the pressure drop and 77.5% for the heat transfer coeficient.
9

Análise do ruído de um refrigerador excitado pelo condensador

Hense, Andrey January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-graduação em Engenharia Mecânica, Florianópolis, 2015. / Made available in DSpace on 2016-10-19T12:41:35Z (GMT). No. of bitstreams: 1 338919.pdf: 1081536 bytes, checksum: a338313a8e9ba627dfd1328f08274973 (MD5) Previous issue date: 2015 / Em sistemas domésticos de refrigeração, o compressor é uma das principais fontes de excitação dinâmica. O condensador é um importante caminho de transmissão da energia vibratória para o gabinete do refrigerador. A vibração do compressor e a oscilação de pressão do fluido refrigerante são os dois tipos de excitação do condensador. Esta dissertação analisa a contribuição do condensador e de cada tipo de excitação para o ruído global de um refrigerador doméstico típico. Para tal, um modelo numérico vibroacústico do condensador foi desenvolvido. Esse modelo inclui o fluido refrigerante e a estrutura do condensador. Propriedades acústicas equivalentes do escoamento bifásico foram determinadas experimentalmente. Esse modelo estima o comportamento dinâmico do condensador e os esforços transmitidos para o gabinete para cada tipo de excitação. Resultados experimentais e analíticos mostram que o condensador possui baixa eficiência de radiação, indicando que a principal contribuição do condensador está na transmissão de energia vibratória ao gabinete. Medindo a vibração do gabinete com o condensador acoplado e desacoplado, foi possível observar que o condensador tem uma contribuição significativa para a vibração do gabinete nas faixas de frequência de 1000 a 1300 Hz e de 2200 e 2500 Hz. Para calcular a radiação sonora do gabinete devido às forças transmitidas pelo condensador, um modelo numérico vibroacústico do gabinete foi desenvolvido utilizando o método de elementos finitos e o método de elementos de contorno. Os modelos foram comparados com dados experimentais indicando uma concordância satisfatória. As simulações do nível de potência sonora do gabinete excitado pelo condensador indicam uma contribuição crítica do condensador nas bandas de 1000 e 1250 Hz, sendo a pulsação a excitação dominante nessa faixa.<br> / Abstract : In domestic refrigeration systems, the compressor is one of the main sources of dynamic excitation. An important vibration energy transmission path to the cabinet is the condenser. The compressor?s vibration and the refrigerant fluid pressure oscillation excite the condenser. This work analyzes the contribution of the condenser and the two types of excitation to the overall noise of a typical household refrigerator. Therefore a vibroacoustic numerical model of the condenser was developed. This model includes the refrigerant and the condenser structural component. Equivalent acoustic properties of the two-phase flow were determined experimentally. The model can estimate the condenser dynamic behavior and the forces transmitted to the cabinet for the two excitement types. Experimental and analytical results showed that the condenser has low radiation efficiency, indicating that the transmission of vibratory energy to the cabinet is the main contribution of the condenser. Measuring the cabinet's vibration response with the condenser coupled and uncoupled, it was observed that the condenser has a significant contribution to the cabinet's vibration in the frequency bands of 1000 to 1300 Hz and 2200 to 2500 Hz. In order to calculate the cabinet sound radiation due to the forces transmitted by the condenser, a vibroacústic numerical model of the cabinet was developed using the Finite Element Method and the Boundary Element Method. The numerical models results were compared with experimental data showing a satisfactory agreement. The simulations of the cabinet sound power level indicated a critical contribution of the condenser in the one-third octave frequencies bands of 1000 and 1250 Hz, where the fluid excitation is dominant.
10

Avaliação dos mecanismos de degradação do filme de polipropileno isotático empregado em capacitores de potência

Teixeira, Mateus Duarte January 2016 (has links)
Orientador: Prof. Dr. Vitoldo Swinka Filho / Coorientador: Drª. Marilda Munaro / Tese (doutorado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Engenharia e Ciência dos Materiais - PIPE. Defesa: Curitiba, 21/03/2016 / Inclui referências : f. 133-140 / Área de concentração: Engenharia e ciência de materiais / Resumo: Capacitores de potência são amplamente utilizados por concessionárias de energia em sistemas elétricos para melhorar a qualidade de energia para seus consumidores. No entanto, problemas com à instalação física, temperatura ambiente e distúrbios elétricos podem causar alterações dos materiais alterando seu desempenho em campo. Como o filme de polipropileno isotático (iPP) é o principal material dielétrico de um capacitor, é importante conhecer como a temperatura e distorções harmônicas do campo elétrico aplicado afetam as propriedades do mesmo. Para isso, amostras de iPP usadas em capacitores de potência foram submetidas a ensaios de envelhecimento acelerado térmico e elétrico em laboratório durante diferentes períodos de tempo e condições de temperatura, atmosfera e campo elétrico. Após cada período de envelhecimento, as amostras foram levadas a ensaios de caracterização óticos, mecânicos, térmicos e elétricos, tais como: microscopia ótica por transmissão; espectroscopia de infravermelho (FTIR), resistência à tração; calorimetria diferencial de varredura (DSC), difração de raios-X (DRX), rigidez dielétrica e espectroscopia de impedância. Os resultados dos ensaios mostraram que a elevação da temperatura do filme iPP gera um aumento da cristalinidade devido ao aumento na dimensão das esferulitas do material polimérico. Adicionalmente, foi verificado que as amostras envelhecidas termicamente em óleo apresentam maior cristalinidade, devido ao efeito plastificante deste. Também foi observado que o aumento da componente harmônica do campo elétrico causa também aumento da cristalinidade e dimensão das esferulitas, mesmo em temperatura ambiente. Por fim, foi verificado que amostras com maior grau de cristalinidade apresentam maior probabilidade de falha elétrica, fato que está associado ao aumento das regiões interfaciais entre as fases no interior do material. Palavras Chaves: Capacitores, Filme de Polipropileno, Alteração Morfológica, Envelhecimento Térmico, Distorção Harmônica, Ruptura Dielétrica. / Abstract: Power capacitors are commonly used by utility companies to improve the quality of the electricity delivered to their consumers. However, problems with physical installation, ambient temperature and electric disturbances may modify the physicchemical properties of its dielectric material, causing changes in capacitor performance. Because a polypropylene (PP) film is the main dielectric component of a capacitor, it is important to know how temperature and harmonic distortion of electric field affects its properties. For this purpose, iPP samples used in power capacitors were aged thermally and electrically in the laboratory for different times, temperature conditions, atmosphere and electric field. After each aging time, samples were taken to optical, mechanical, thermal and electrical characterization tests, such as transmission optical microscopy; tensile strength; differential scanning calorimetry (DSC), X-ray diffraction (XRD), electrical breakdown and impedance spectroscopy. The test results showed that the elevation of iPP film temperature and electrical disturbances produces an increase in crystallinity due to increase the size of the spherulites in the polymer chain. Additionally, it was found that the samples thermally aged in oil have higher crystallinity due to the plasticizing effect. It was also observed that increasing the harmonic frequency of the electric field also causes increase in crystallinity and spherulites size, even at room temperature. Finally, it was observed that samples with a higher degree of crystallinity have an increase of the probability of electrical failure. This fact was associated with increased at interfacial areas between the phases inside the material caused by the increase in crystallinity and spherulites size. Keywords: Capacitors: Capacitor, Polypropylene Film, Morphology Changes, Thermal Aging, Harmonic Distortion And Dielectric Breakdown.

Page generated in 0.0749 seconds