Spelling suggestions: "subject:"capacitancevoltage control"" "subject:"capacitancevoltage coontrol""
1 |
Control of Four-Level Hybrid Clamped Converter for Medium-Voltage Variable-Frequency DrivesPan, Jianyu 02 October 2019 (has links)
No description available.
|
2 |
On the Internal Dynamics and AC-Motor Drive Application of Modular Multilevel ConvertersAntonopoulos, Antonios January 2014 (has links)
This thesis is an effort to investigate the operation and the performanceof modular multilevel converters (M2Cs). Proven to be the most promisingtopology in high-voltage high-power applications, it is necessary to put aneffort in understanding the physical laws that govern the internal dynamicsof such converters, in order to design appropriate control methods. AlthoughM2Cs belong to the well-studied family of voltage-source converters (VSCs),and claim a modular structure, their control is significantly more complicatedcompared to two- or three-level VSCs, due to the fact that a much highernumber of switches and capacitors are needed in such a topology. This thesishighlights the important parameters that should be considered when designingthe control for an M2C, through analyzing its internal dynamics, and alsosuggests ways to control such converters ensuring stable operation withoutcompromising the performance of the converter.Special focus is given on ac motor-drive applications as they are very demandingand challenging for the converter performance. Interactions betweenthe internal dynamics and the dynamics of the driven motor are experimentallyinvestigated. The problem of operating the converter when connectedto a motor standing still is visited, even under the condition that a greatamount of torque and current are requested, in order to provide an idea forthe converter requirements under such conditions. Finally, an optimization ofthe converter operation is suggested in order to avoid overrating the convertercomponents in certain operation areas that this is possible.All analytical investigations presented in this thesis are confirmed by experimentalresults on a laboratory prototype converter, which was developedfor the purposes of this project. Experimental verification proves the validityof the theoretical investigations, as well as the correct performance of thecontrol methods developed during this project on a real, physical converter,hoping that the results of this thesis will be useful for large-scale implementations,in the mega- or even giga-watt power range. / Denna avhandling är ett försök att undersöka drift och egenskaper avmodulära multinivåomvandlare (M2C:er). Eftersom denna topologi anses varaden mest lovande inom högspänings-högeffekt-tillämpningar är, och somett underlag för att kunna formulera lämpliga styrmetoder, är det nödvändigtatt lägga kraft i att försöka förståde fysikaliska lagar som styr den inredynamiken i sådana omvandlare. Även om M2C:erna tillhör den välstuderadefamiljen av spänningsstyva omvandlare (VSC:er), och har en modulärstruktur, är deras reglering avsevärt mer komplicerad jämfört med två- ellertre-nivåomvandlare, eftersom ett mycket större antal switchar och kondensatorerär nödvändiga i en sådan topologi. Denna avhandling sätter fingretpå de parametrar som måste beaktas när man konstruerar regleringen för enM2C, genom att analysera den interna dynamiken, samt att föreslå sätt attstyra sådana omvandlare såatt stabil drift kan säkerställas utan att negativtpåverka prestanda.Ett speciellt fokus läggs på växelströmsmotordrifter eftersom de är särskiltutmanande vad gäller prestanda. Växelverkan mellan den interna dynamikenoch motorns dynamik undersöks experimentellt. Problemet att driva motornvid stillestånd behandlas även i fallet med hög ström och högt moment för atterhålla kunskap om kraven påomvandlaren i sådana fall. Slutligen föreslås enoptimering av omvandlarens drifttillstånd för att undvika överdimensioneringav omvandlarens komponenter i de fall detta är möjligt.Alla analytiska undersökningar som läggs fram i denna avhandling är bekräftadegenom experimentella resultat från en laboratorieomvandlare, somutvecklats inom ramen för detta arbete. Den experimentella verifieringen bevisargiltigheten av alla teoretiska undersökningar. Den visar också på demycket goda prestanda som de utvecklade styrmetoderna har vid drift aven verklig fysisk omvandlare. Förhoppningen är att resultaten från detta arbetekan komma till använding i storskaliga implementerinar i mega- ellergiga-wattklassen. / <p>QC 20141201</p>
|
3 |
[pt] CONTROLE DO INVERSOR DE UMA USINA FOTOVOLTAICA PARA MELHORA DA ESTABILIDADE TRANSITÓRIA DE UMA MÁQUINA SÍNCRONA / [en] PROPOSED INVERTER CONTROL OF A PHOTOVOLTAIC GENERATION UNIT FOR THE IMPROVEMENT OF THE TRANSIENT STABILITY OF A SYNCHRONOUS MACHINEOSCAR CUARESMA ZEVALLOS 08 April 2021 (has links)
[pt] O incremento de geração fotovoltaica de grande porte traz consideráveis mudanças nas características operativas e dinâmicas do sistema quando este é submetido a grandes distúrbios. Um dos problemas
técnicos mais relevantes é a estabilidade transitória, já que a geração intermitente ligada ao sistema por conversores eletrônicos não contribui para o aumento da inércia total do sistema. Entretanto, os conversores eletrônicos podem, potencialmente, trazer novas oportunidades de controle rápido para
dar suporte aos geradores síncronos em resposta a um distúrbio severo. No presente trabalho propõe uma estratégia de controle para inversores fotovoltaicos baseado na injeção da corrente com um grande impacto na resposta transitória do ângulo do rotor da máquina síncrona, identificada
através da análise de sensibilidade dos autovalores e dos fatores de participação. Ao fazer isso, é possível aumentar a potência ativa da máquina síncrona próximo do seu valor pré-falta, reduzindo o desequilíbrio entre o torque elétrico e mecânico. A estratégia de controle proposta foi testada experimentalmente, utilizando um inversor e uma montagem máquina síncrona-motor e, através da simulação de um sistema híbrido com um sistema fotovoltaico de grande porte. Os resultados mostram que a estratégia
de controle proposta não está apenas em conformidade com os requisitos dos código da rede para melhorar a estabilidade da tensão durante uma perturbação grave, mas também é capaz de manter a estabilidade transitória da rede provando, assim, ser uma melhor alternativa em relação à capacidade
FRT requerida pelos códigos de rede. / [en] The increase in photovoltaic generation has caused changes in the
power system s operative and dynamic characteristics when subjected to
severe disturbances. One of the most relevant problems associated with this
renewable energy source is the transient stability, as renewable generation
connected to the system by electronic converters does not contrinute to the
increase of the total inertia of the system. However, electronic converters can
potentially bring new opportunities for rapid control to support synchronous
generators in response to severe disturbance. The present work proposes a
control strategy for photovoltaic inverters based on the injection of the
current with a major impact on the transient response of the synchronous
machine rotor angle, identified through the eigenvalue sensitivity analysis
and the participation factors. By doing so, it is possible to increase the
synchronous machine active power output close to its pre-fault value,
reducing the disequilibrium between mechanical and electrical torque. The
proposed control strategy was experimentally tested using an inverter and
a synchronous-motor machine assembly and, by simulating a hybrid system
with a large photovoltaic system. The results show that the proposed control
strategy not only conforms to the grid codes requirements to improve voltage
stability during a severe disturbance, but is also able to maintain transient
stability thus proving to be a better alternative to the FRT capability
required by the grid codes.
|
Page generated in 0.0492 seconds