Spelling suggestions: "subject:"capillary electrophoresis."" "subject:"papillary electrophoresis.""
221 |
Peroxyoxalate Chemiluminescence for Miniaturized Analytical Flow SystemsJonsson, Tobias January 2003 (has links)
<p>This thesis deals with the peroxyoxalate chemiluminescence (POCL) reaction and its application as a detection technique in flow systems for chemical analysis. Particularly, miniaturized flow systems aimed for separation of molecules. In such systems, a high light intensity and a rapid development of the emission are the desired reaction characteristics, for reasons discussed in this text. The work tries to develop an understanding of the chemical processes involved in POCL, with special emphasis to the species favoring or hindering a rapid light evolution. Hence, is the focus placed on the nature of catalysis and the desired properties of substances acting as catalysts in this reaction. Consequently, the scientific papers on which this work is founded includes both systematic stopped-flow studies of catalyst candidates and of the causes for diminished light emission. In addition, multivariate strategies for reaction optimization in practical analysis situations are treated, and the application of the POCL technique to detection of serum-extracted neuroactive steroids, derivatized with fluorescent moieties, is presented.</p><p>From the experiments in this thesis it is clear nucleophilic catalysts are the most efficient enhancing compounds, which means that they must possess a carefully balanced characteristics of nucleophilicity, leaving group ability, and basicity. The investigations also conclude that the feature of basicity efficiently can be delegated to a non-nucleophilic co-catalyst, which allow the use of nucleophilic catalysts that need to be deprotonated to be active. This thesis also shows the importance of minimizing the amount of competing nucleophiles at the site of reaction to maintain the emission. This implies that also solvents and buffer substances should be carefully chosen not to interfere with the emission process.</p><p>The most promising combination of catalysts found in this work was 4,5- dichloroimidazole together with 1,2,2,6,6-pentamethylpiperidne. This arrangement was capable of speeding the reaction more than tenfold while increasing the maximum emission intensity by about the same factor.</p>
|
222 |
Portable capillary electrophoresis system with LED-absorbance photometric and LED-induced fluorescence detection : Design, characterisation and testingStjernlöf, Anna January 2008 (has links)
<p>Capillary electrophoresis (CE) has a wide range of applications in the field of analytical chemistry. In general the most expensive part in a CE system is the detector due to the fact that the detector must have a high sensitivity for small detection volumes and low concentrations. Building portable instruments is one way to make the instruments cheaper and has the advantage that they can be used virtually everywhere. However, downscaling of CE instruments puts some extra demands on the detector. This report describes the design and building of two homemade light-emitting diode (LED) based detectors; a LEDabsorbance photometric detector (LED-AP) and a LED-induced fluorescence (LED-IF) detector. The main goal was to install them inside a portable CE and make a simple separation. The performance of the two detectors had to be evaluated before the main goal could be achieved. p-Nitrophenol was used to create a sensitivity graph for the LED-AP detector, calculating the upper linearity to 5.6 mM when the sensitivity had dropped 10 % caused by non-linearity. The sensitivity graph also showed that the detector had an effective pathlength of 74.2 µm and a stray light of 4.5 % for a 75 µm i.d fused-silica capillary. The LED-IF detector was evaluated by determining the limit of detection (LOD) for fluorescein, at a signal to noise ratio of 3. The LOD was 0.72 µM ± 0.01 µM when immersion oil was used to limit the light scattering from the optic fibres in to the capillary and 0.58 µM ±0.02 µM when silicone oil was used. Without doing any improvements only the LED-AP detector could be used in the portable CE. As a common application area for portable CE instruments is environmental analysis, indirect detection using p-nitrophenol as a probe for separating anions was done to test the system. All analytes were eluted in less than 4 minutes.</p>
|
223 |
Affinity capillary electrophoresis of Beta-2-glycoprotein I and Anionic phospholipidsOlsson, Ola January 2010 (has links)
No description available.
|
224 |
Determination of self association constant between bovine insulin molecules by capillary zone electrophoresisKhalifeh, Iman January 2005 (has links)
<p>Capillary electrophoresis (CE) is an analytical technique that is very useful for investigating processes that modify the charge and mass of proteins and polypeptide pharmaceuticals. This report explores the ability of CE to determine the aggregation constant between insulin molecules. Bovine insulin is a polypeptide (Mw=5733, pI = 5.3) that has two α-amino groups (Gly and Phe) and one ε–amino group (Lys). Analysis of concentration dependence of electrophoretic mobility of insulin at different conditions yields the association constant for dimerization of insulin. The association constant estimates how tight the peptide molecules are associated. The association constant is a useful factor to evaluate the purity of a peptide or protein sample.</p><p>The association reaction of bovine insulin molecules was found to be favoured by temperature. The association constants were 7200 M -1, 8000 M -1, and 36000 M -1 at 15 oC, 25 oC and 35 oC, respectively. The interactions between the peptide molecules increase at higher temperature, resulting in stronger association. The association constant was estimated to be 3000 M -1in the presence of dioxane (5%, w/v %) at 25 oC. However, the interaction sites remain to be explored.</p>
|
225 |
Signal processing and amplifier design for inexpensive genetic analysis instrumentsChoi, Sheng Heng 11 1900 (has links)
The Applied Miniaturisation Laboratory (AML) has recently built a laser-induced fluorescent capillary electrophoresis (LIF-CE) genetic analysis instrument, called the Tricorder Tool Kit (TTK). By using a photodiode instead of photomultiplier tubes in the optical detection, the AML has lowered the cost and size compared to commercial LIF-CE products. However, maintaining an adequate signal-to-noise (SNR) and limit of detection (LOD) is a challenge.
By implementing a multistage amplifier, we increased the bandwidth and voltage swing while maintaining the transimpedance gain compared to the previous design. We also developed signal processing algorithms for post-experiment processing of CE. Using wavelet transform, iterative polynomial baseline fitting, and Jansson's deconvolution, we improved the SNR, reduced baseline variations, and separated overlapping peaks in CE signals. By improving the electronics and signal processing, we lowered the LOD of the TTK, which is a step towards the realisation of inexpensive point-of-care molecular medical diagnosis instruments. / Computer, Microelectronic Devices, Circuits and Systems
|
226 |
A proteomics investigation of the HIV-1 infection in T-cells /Bonn, Ryan. January 2006 (has links)
Thesis (Ph. D.)--University of Washington, 2006. / Vita. Includes bibliographical references (leaves 106-113).
|
227 |
Synthesis, characterization and capillary electrophoretic use of new, single-isomer hexasulfated alpha-cyclodextrinsLi, Shulan 29 August 2005 (has links)
The first three, pure, single-isomer, 6-O-sulfo a-cyclodextrins, the sodium salts of hexakis(6-O-sulfo)-a-CD (HxS), hexakis(2,3-di-O-methyl-6-O-sulfo)-a-cyclodextrin (HxDMS) and hexakis(2,3-di-O-acetyl-6-O-sulfo)-a-cyclodextrin (HxDAS) have been synthesized, analytically characterized and utilized as chiral resolving agents in capillary electrophoresis. The purity of each synthetic intermediate and of the final product was determined by HPLC-ELSD and indirect UV-detection capillary electrophoresis. The structural identity of each intermediate and final product was verified by 1D and 2D NMR, and mass spectrometry.HxS, HxDMS and HxDAS have been used to separate a series of neutral, basic, ampholytic and acidic enantiomers in pH 2.5 and pH 9.5 aqueous and acidic methanol background electrolytes using capillary electrophoresis. Rapid separations with satisfactory peak resolution values were obtained for most of the analytes, indicating that HxS, HxDAS and HxDMS can serve as chiral resolving agent for a wide range of analytes. The observed separation patterns follow the predictions of the CHArged Resolving agent Migration (CHARM) model. The separation patterns observed with HxS, HxDAS and HxDMS as chiral resolving agent were compared with those of (1) b-cyclodextrin analogues, such as, heptakis(6-O-sulfo)-b-cyclodextrin (HS), heptakis(2,3-di-O-acetyl-6-O-sulfo)-b-cyclodextrin (HDAS) and heptakis(2,3-di-O-methyl-6-O-sulfo)-b-cyclodextrin (HDMS); (2) g-cyclodextrin analogues, such as, octakis(6-O-sulfo)-g-cyclodextrin (OS), octakis(2,3-di-O-acetyl-6-Osulfo)- g-cyclodextrin (ODAS) and octakis(2,3-di-O-methyl-6-O-sulfo)-g-cyclodextrin (ODMS). The effects of the structure of the analytes, and those of the pH and the solvent of the background electrolyte were also studied.
|
228 |
Capillary electrophoresis as a fast and universal tool in soil analysisHowald, Markus, Elsenbeer, Helmut, Laczko, Endre, Schlunegger, Urs Peter January 1995 (has links)
Fast analysis of different species of molecules in soils is investigated by capillary electrophoresis (CE). Several CE techniques for the analysis of inorganic ions and carbohydrates have been tested. With regard to the intents of pedologists and the usually large number of soil analyses a bundle of CE systems is proposed, capable of effecting time-saving soil analyses. Adapted
electrolyte systems recently published and new separation systems are described. Examples of the application of these methods to two different soil samples are presented.
|
229 |
Peroxyoxalate Chemiluminescence for Miniaturized Analytical Flow SystemsJonsson, Tobias January 2003 (has links)
This thesis deals with the peroxyoxalate chemiluminescence (POCL) reaction and its application as a detection technique in flow systems for chemical analysis. Particularly, miniaturized flow systems aimed for separation of molecules. In such systems, a high light intensity and a rapid development of the emission are the desired reaction characteristics, for reasons discussed in this text. The work tries to develop an understanding of the chemical processes involved in POCL, with special emphasis to the species favoring or hindering a rapid light evolution. Hence, is the focus placed on the nature of catalysis and the desired properties of substances acting as catalysts in this reaction. Consequently, the scientific papers on which this work is founded includes both systematic stopped-flow studies of catalyst candidates and of the causes for diminished light emission. In addition, multivariate strategies for reaction optimization in practical analysis situations are treated, and the application of the POCL technique to detection of serum-extracted neuroactive steroids, derivatized with fluorescent moieties, is presented. From the experiments in this thesis it is clear nucleophilic catalysts are the most efficient enhancing compounds, which means that they must possess a carefully balanced characteristics of nucleophilicity, leaving group ability, and basicity. The investigations also conclude that the feature of basicity efficiently can be delegated to a non-nucleophilic co-catalyst, which allow the use of nucleophilic catalysts that need to be deprotonated to be active. This thesis also shows the importance of minimizing the amount of competing nucleophiles at the site of reaction to maintain the emission. This implies that also solvents and buffer substances should be carefully chosen not to interfere with the emission process. The most promising combination of catalysts found in this work was 4,5- dichloroimidazole together with 1,2,2,6,6-pentamethylpiperidne. This arrangement was capable of speeding the reaction more than tenfold while increasing the maximum emission intensity by about the same factor.
|
230 |
Affinity capillary electrophoresis of Beta-2-glycoprotein I and Anionic phospholipidsOlsson, Ola January 2010 (has links)
No description available.
|
Page generated in 0.0992 seconds