• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 18
  • 2
  • 1
  • Tagged with
  • 48
  • 48
  • 29
  • 18
  • 17
  • 16
  • 11
  • 10
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

The pace of innovation : patterns of innovation in the cardiac pacemaker industry /

Hidefjäll, Patrik, January 1900 (has links)
Diss. Linköping : Univ.
22

Cardiac memory studies in two human models /

Wecke, Liliane, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2006. / Härtill 5 uppsatser.
23

New methods for quantifying the synchrony of contraction and relaxation in the heart

Fornwalt, Brandon Kenneth. January 2008 (has links)
Thesis (Ph.D.)--Biomedical Engineering, Georgia Institute of Technology, 2008. / Committee Chair: Oshinski, John N.; Committee Member: Fyfe, Derek A.; Committee Member: León, Angel R.; Committee Member: Skrinjar, Oskar; Committee Member: Taylor, W. Robert.
24

Avaliação ecocardiografica da terapia de ressincronização cardiaca : dois anos de seguimento / Echocardiographic assessment of the cardiac resynchronization therapy : two years of follow-up

Veiga, Viviane Cordeiro, 1976- 12 August 2018 (has links)
Orientador: Salomon Soriano Ordinola Rojas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-12T15:05:14Z (GMT). No. of bitstreams: 1 Veiga_VivianeCordeiro_M.pdf: 4383215 bytes, checksum: 4ac235c87c9173ad91395fd7c6466208 (MD5) Previous issue date: 2008 / Resumo: Introdução A terapia de ressincronização cardíaca é uma opção efetiva nos pacientes com insuficiência cardíaca avançada. No entanto, 20 a 30% dos pacientes não apresentam benefícios à esta terapêutica. Critérios clínicos, eletrocardiográficos e ecocardiográficos têm sido estudados na tentativa de selecionar os pacientes que serão beneficiados com a ressincronização cardíaca, sendo o ecocardiograma um método utilizado tanto na seleção, quanto na avaliação e otimização desta terapêutica. Objetivo: O objetivo deste trabalho é analisar a utilização do ecocardiograma na avaliação da terapia de ressincronização cardíaca em pacientes portadores de insuficiência cardíaca refratária, no seguimento a curto prazo (dez dias) e após dois anos de evolução. Casuística e Método: Foram avaliados 20 pacientes com indicação de implante de marcapasso biventricular para terapia de ressincronização cardíaca no período de dois anos, sendo 16 (80%) do sexo masculino, com idade variando de 27 a 80 anos (59,70 ± 12,59 anos). A etiologia da cardiomiopatia era isquêmica em 10 pacientes (50%), chagásica em seis (30%) e idiopática em 4 (20%). Quinze pacientes encontravam-se em classe funcional III (New York Heart Association) e cinco em classe funcional IV no momento do implante do marcapasso. Foi aplicado o Questionário de Qualidade de Vida de Minnesota e realizado o teste de caminhada de seis minutos para avaliação das condições clínicas dos pacientes. Realizado ecodopplercardiograma bidimensional para avaliação da função ventricular, diâmetros cavitários, índice de performance miocárdica, estudo da dissincronia interventricular (avaliação do atraso eletromecânico entre os ventrículos esquerdo e direito) e intraventricular (análise pelo modo unidimensional e Doppler tecidual), da função diastólica e do grau da regurgitação mitral. Dez dias após o implante do marcapasso biventricular, foi repetida toda a avaliação inicial e, novamente, após dois anos. Resultados: Em dois anos, cinco pacientes (25%) foram à óbito, sendo que destes, quatro apresentavam etiologia chagásica. A duração média do complexo QRS era de 154,5±18,48 x 129,0±22,91 x 134,0±24,14 ms, respectivamente nos períodos pré-operatório, dez dias e dois anos de pós-operatório. Não houve alteração estatisticamente significante da fração de ejeção entre os períodos pré-operatório e dez dias, mas houve alteração significante entre os períodos pré-operatório e dois anos e dez dias e dois anos. No seguimento de dez dias, houve piora da dissincronia intraventricular avaliada pelo Doppler tecidual, assim como a pontuação no escore de qualidade de vida foi maior, no grupo óbito. Conclusão: A ecocardiografia é uma tecnologia em evolução e dos parâmetros avaliados, somente a avaliação da dissincronia intraventricular pelo Doppler tecidual após o procedimento, foi capaz de predizer a eficácia da terapia de ressincronização cardíaca, em relação à mortalidade. Não houve correlação entre os parâmetros ecocardiográficos e a melhora clínica de alguns pacientes. / Abstract: Introduction In the cardiac resynchronization therapy is an effective option for patients with advanced heart failure. However, 20 to 30% of patients did not show benefits to this therapy. Clinical criteria, electrocardiography and the echocardiography have been studied in an attempt to select the patients who will benefit from the cardiac resynchronization, and the echocardiogram is a method used in both the selection, as in the evaluation and optimization of this therapy. Objective: The objective of this study is to evaluate the use of echocardiography in the evaluation of patients undergoing cardiac resynchronization therapy for a period of two years. Patients and Methods: We evaluated 20 patients with the implantation of biventricular pacemaker for cardiac resynchronization therapy for over two years, and 16 (80%) males, ranging in age from 27 to 80 years (59.70±12.59 years). The etiology of cardiomyopathy was ischemic in 10 patients (50%), Chagas disease in six (30%) and idiophatic in 4 (20%). Fifteen patients were in functional class III (New York Heart Association) and five in functional class IV at the time of implantation of the pacemaker. We applied the Quality of Life Questionnaire of Minnesota and conducted the test of a six-minute walk to evaluate the clinical conditions of patients. Directed two-dimensional Doppler echocardiography for evaluation of ventricular function, cavity diameters, myocardial performance index, study of interventricular dyssynchrony (eletromechanical delay left ventricle - the right ventricle) and intraventricular (by way dimensional analysis and tissue Doppler), the diastolic function and degree of mitral regurgitation. Ten days after implantation of biventricular pacemaker, was repeated throughout the initial assessment and again after two years. Results: In two years, five patients (25%) were to death, and that these, four had Chagas disease. The average duration of the QRS complex was 154.5±18.48 x 129.0±22.91 x 134.0±24.14 ms, respectively in preoperative, ten days and two years after surgery. There was no statistically significant change in the ejection fraction between preoperative and ten days but there was significant change between periods preoperative and 2 years and 10 days and 2 years. Following ten days, the evaluation of intraventricular dyssynchrony by tissue Doppler and quality of life scores were significantly higher in the group died. Conclusion: The echocardiography is an evolving technology and the parameters evaluated, only the assessment of intraventricular dyssynchrony by Doppler tissue after the procedure was able to predict the effectiveness of the cardiac resynchronization therapy, in relation to mortality. There was no correlation between echocardiographic parameters and clinical improvement in some patients. / Mestrado / Mestre em Cirurgia
25

Dorsal Spinal Cord Stimulation Obtunds the Capacity of Intrathoracic Extracardiac Neurons to Transduce Myocardial Ischemia

Ardell, Jeffrey L., Cardinal, René, Vermeulen, Michel, Armour, J. A. 01 August 2009 (has links)
Populations of intrathoracic extracardiac neurons transduce myocardial ischemia, thereby contributing to sympathetic control of regional cardiac indices during such pathology. Our objective was to determine whether electrical neuromodulation using spinal cord stimulation (SCS) modulates such local reflex control. In 10 anesthetized canines, middle cervical ganglion neurons were identified that transduce the ventricular milieu. Their capacity to transduce a global (rapid ventricular pacing) vs. regional (transient regional ischemia) ventricular stress was tested before and during SCS (50 Hz, 0.2 ms duration at 90% MT) applied to the dorsal aspect of the T1 to T4 spinal cord. Rapid ventricular pacing and transient myocardial ischemia both activated cardiac-related middle cervical ganglion neurons. SCS obtunded their capacity to reflexly respond to the regional ventricular ischemia, but not rapid ventricular pacing. In conclusion, spinal cord inputs to the intrathoracic extracardiac nervous system obtund the latter's capacity to transduce regional ventricular ischemia, but not global cardiac stress. Given the substantial body of literature indicating the adverse consequences of excessive adrenergic neuronal excitation on cardiac function, these data delineate the intrathoracic extracardiac nervous system as a potential target for neuromodulation therapy in minimizing such effects.
26

Device, Method, and Algorithm to Assess Changes in Cardiac Output via Intracardiac Impedance Monitoring

Schau, Geoffrey Fredrick 12 June 2015 (has links)
Cardiac output, the volume of blood pumped by the heart over time, is a powerful clinical metric used by physicians to assess overall cardiac health and patient well-being. However, current cardiac output estimation methods are typically invasive, time-consuming, expensive, or some combination of all three. Patients that receive artificial cardiac pacemaker devices are particularly susceptible to cardiac dysfunction and often require long-term cardiac monitoring support. This thesis proposes a novel cardiac output monitoring solution which leverages an implantable intracardiac medical device. The principles of traditional impedance cardiography, an established cardiac output monitoring technique in practice for over fifty years, have been adapted to incorporate a leadless artificial cardiac pacemaker, an implantable medical device contained entirely within the heart. This novel method, colloquially referred to as Z-Cardio, monitors time-varying intracardiac impedance modulation to assess changes in cardiac output. In this study, technologies both old and new are synthesized to produce a novel and effective method of monitoring a critical metric of cardiac health.
27

Avaliação de dessincronia atrioventricular em portadores de marca-passo bicameral devido à doença do nó sinusal e bloqueio atrioventricular de primeiro grau / Evaluation of atrioventricular dyssynchrony in patients with dual-chamber pacemaker implanted due to sinus node disease and first degree atrioventricular block

Ferrari, Andres Di Leoni 18 May 2017 (has links)
INTRODUÇÃO: O intervalo PR longo, em conjunto com a duração e a morfologia do QRS gerado pela estimulação cardíaca artificial, associam-se com dessincronia e disfunção cardíaca em diferentes níveis. Na doença do nó sinusal, durante a programação do marca-passo, podemos optar por duas estratégias: PR longo com QRS estreito (quando se busca evitar a ativação ventricular em detrimento do sincronismo atrioventricular) ou PR otimizado e QRS largo estimulado pelo marca-passo (quando se busca corrigir o intervalo atrioventricular em detrimento da sincronia ventricular). Neste estudo, buscamos comparar a evolução clínica e estrutural cardíaca destas estratégias. MÉTODOS: Acompanhou-se por 1 ano uma coorte com doença do nó sinusal, bloqueio atrioventricular de 1º grau (doença binodal) e marca-passo DDD. Através da ecocardiografia Doppler de fluxo transmitral avaliou-se a duração do enchimento diastólico ventricular e sincronia atrioventricular (? ondas E+A>=40% do ciclo cardíaco). Os pacientes dessincrônicos (DAV) tiveram o intervalo atrioventricular otimizado (intervenção) ao melhor rendimento hemodinâmico, porém com QRS estimulado. Estes retornavam ao PR basal após 6 meses (cross-over). Os sincrônicos (SAV) foram mantidos sob PR longo e QRS intrínseco durante todo o seguimento (controles). RESULTADOS: Quarenta e três pacientes foram incluídos e 41 completaram o estudo (idade média= 71,5 anos). Confirmou-se a existência dos 2 grupos (p= <0.001): os SAV (n=19), distintos daqueles com dessincronia atrioventricular (DAV, n=24). PR>=263ms mostrou especificidade de 78,9% para diagnóstico de dessincronia AV, e a maior duração do PR mostrou relação direta com pior função sistólica ventricular basal. Os DAV eram predominantemente homens, tinham PR mais longos (média= 283,5ms) e menor duração da diástole (p= 0.032). Um subgrupo dos DAV com PR >300ms mostrou pior qualidade de vida, maior duração do QRS quando estimulado, e dessincronia não corrigível por otimização. De modo notável, em 6 meses, o grupo DAV mostrou tendência a melhora da FEVE apesar do QRS alargado, e decréscimo ao retornar ao basal. O grupo SAV apresentava PR longo antifisiológico e evolutivamente piora da regurgitação mitral (p= 0.008) e também registros de fibrilação atrial de aparição mais precoce. Foram preditores independentes de dessincronia atrioventricular o PR >263ms (RR= 1,84; p= 0.024) e a duração da diástole inferior a 40% do ciclo cardíaco (RR= 0,99; p<0.001). CONCLUSÕES: Em pacientes com doença binodal e marca-passo DDD, a mera intenção de evitar o QRS largo da estimulação ventricular artificial não resolve todos os problemas. Intervalos PR longos (>263ms) associados ao decréscimo do enchimento diastólico ventricular caracterizariam outro prejuízo eletromecânico cardíaco: a dessincronia atrioventricular, disfunção que tem repercussão hemodinâmica, clínica e estrutural. / BACKGROUND: Long PR interval and wide QRS duration duo to ectopic morphology generated by artificial cardiac pacing are associated with cardiac dysfunction and dyssynchrony at different levels. When programming a permanent pacemaker in sinus node disease, two strategies can be considered: long PR with narrow QRS (avoiding ventricular pacing despite the risk of losing atrioventricular syncrony) or optimized PR interval with pacemaker-induced wide QRS (aiming to correct the atrioventricular delay despite loss of the ventricular synchrony). In this study, we aimed to compare the clinical and cardiac structural outcomes of these two strategies. METHODS: Sudy a cohort of patients with sinus node disease, first-degree AV block (binodal disease) and DDD pacemaker was followed for 1 year follow-up. atrioventrucular synchrony (AVS) was assessed echocardiographically by the ventricular diastolic filling time on Doppler transmitral flow: sum of the duration of E and A waves >=40% of the cardiac cycle. Patients with AV dyssynchrony (AVD) had the AV delay optimized (intervention group) for the best hemodynamic performance, but under wide artificially paced QRS. These returned to baseline PR interval after 6 months (cross-over). Those with AVS were kept under intrinsic QRS throughout the follow-up period despiste long PR interval (control group). RESULTS: Forty-three patients were included (mean age = 71.5 years), and 41 completed the 1-year follow-up. The existence of the 2 groups was confirmed (p<=0.001): patients with AVS (n=19), differed from those with AVD (n=24). Within a homogeneous sample (mean age= 71.5 years), PR >=263 ms had a specificity of 78.9% for the diagnosis of AVD, and longer PR intervals were associated with worse baseline ventricular systolic function. Most patients with AVD were men, had longer PR intervals (mean= 283.5 ms), and had significantly lower diastole duration (p= 0.032). A subgroup of AVD patients with PR >300 ms had poorer quality of life, significantly greater use of ?-blockers (p= 0.011), longer paced QRS width, and AV dyssynchrony that is non-correctable by optimization. Notably, at 6 months, the AVD group lean towards to have better LVEF values despite the wide QRS and a decrease when returning to baseline. Patients with AVS also had PR intervals different from the physiological condition (157.9 to 330 ms) and, over time, had worsening of mitral regurgitation (p=0.008) and earlier atrial fibrillation. PR>263 ms (RR= 1.84; p= 0.024) and diastole duration <40% of the cardiac cycle (RR= 0.99; p<0.001) were independent predictors of AVD. CONCLUSIONS: For patients with binodal disease and DDD pacemaker, the strategy of avoiding the wide QRS, usually applied by modern algorithms for minimizing ventricular pacing, is not enough to solve all problems. Long PR intervals (>=263 ms) may be associated with decreased ventricular diastolic filling time and characterize another cardiac electromechanical impairment: AV dyssynchrony, with hemodynamic, clinical and structural repercussions by itself.
28

Estimulação multidirecional de celulas cardiacas : instrumentação e experimentação / Multidirectional stimulation of cardiac cells : instrumentation and experimentation

Fonseca, Alexandra Valenzuela Santelices da 12 March 2009 (has links)
Orientadores: Jose Wilson Magalhaes Bassani, Rosana Almada Bassani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-15T01:38:31Z (GMT). No. of bitstreams: 1 Fonseca_AlexandraValenzuelaSantelicesda_M.pdf: 1311974 bytes, checksum: ab061a6f8d63a1175d6a3c9281e0704e (MD5) Previous issue date: 2009 / Resumo: O procedimento mais efetivo para reverter arritmias cardíacas consiste na aplicação de choques elétricos de alta intensidade, como e o caso da desfibrilação. Estimulação com campos elétricos (E) elevados, entretanto, exerce efeitos deletérios sobre o músculo cardíaco, podendo causar disfunções elétrica e contrátil e até a morte celular. Privilegiar a estimulação na direção longitudinal, para qual o limiar de excitação das células cardíacas e menor, seria uma forma de se reduzir a amplitude do estimulo sem perder a efetividade da estimulação. Para isto, foi desenvolvido e testado, em miócitos ventriculares orientados de maneira aleatória, um sistema de estimulação multidirecional automática que permite o chaveamento controlado de estímulos sequênciais para três diferentes pares de eletrodos (cada um correspondendo a uma direção) em um intervalo de tempo inferior a duração do potencial de ação (período em que a célula se encontra eletricamente refrataria). A estimulação multidirecional com uma intensidade de E 20% acima do limiar estimulatório (1,2× ETM) dobrou o recrutamento (excitação) de células (80 vs. 40% com estimulação unidirecional, p<0,001). Adicionalmente, o recrutamento com a estimulação multidirecional automática foi maior (p< 0,001) do que a soma dos recrutamentos obtidos com a estimulação em cada direção individualmente (sem intersecção), o que sugere que a estimulação sublimiar durante o procedimento automático pode aumentar a excitabilidade celular. Foi observado também que, para uma dada amplitude do estimulo, o uso da forma de onda bipolar (para a qual o valor de ETM foi menor que para pulsos monopolares: 3,2 ± 0,1 vs. 3,9 ± 0,1 V/cm; p< 0,001) promoveu um recrutamento maior do que com o pulso monopolar (recrutamento de 50% das células foi obtido com 2,97 ± 0,04 e 4,18 ± 0,05 V/cm para pulsos bipolares e monopolares, respectivamente; p< 0,05). A combinação da estimulação multidirecional automática com o uso da forma de onda bipolar permitiu, portanto, uma redução de cerca de 50% no valor do E absoluto (3,8 vs. 7,8 V/cm com estimulação unidirecional e pulso monopolar) para um recrutamento de ~80% das células. A aplicação destes procedimentos na estimulação cardíaca (marcapasso e desfibrilação) pode otimizar o processo, levando a uma melhor eficiência e uma menor incidência de lesão. / Abstract: The most effective procedure to revert cardiac arrhythmias consists in the application of high intensity electric discharge, such as in cardiac defibrillation. Nevertheless, stimulation using high electric fields (E) may cause injury to the cardiac muscle, generating electric and contractile dysfunctions and even cell death. A possible way to reduce the stimulus intensity while maintaining the stimulation effectiveness would be stimulate cardiac cells with E applied parallel to the cell major axis, in which case the stimulation threshold is lower. To test this possibility, a multidirectional stimulation system was developed and tested on randomly-oriented rat ventricular myocytes. The system allows the controlled switching of sequential stimuli delivered to three different pairs of electrodes (each one corresponding to one direction), in a period shorter than the action potential duration (when cell is electrically refractory). The multidirectional stimulation with E intensity 20% above the stimulation threshold (1.2× ETM) doubled the percentage of recruited (excited) cells (~80 vs. ~40 % with unidirectional stimulation, p<0.001). Additionally, recruitment with automatic multidirectional stimulation was greater (p< 0.001) than the sum of recruitments obtained from stimulation of each direction individually (without intersection), which is suggestive that subthreshold stimulation during the automatic procedure might enhance cell excitability. Moreover, it was observed that for a given absolute stimulus amplitude, the use of biphasic waveforms (for which ETM was lower than for monophasic pulses: 3.2 ± 0.1 vs. 3.9 ± 0.1 V/cm; p< 0.001) promoted higher recruitment than monophasic stimuli (50% recruitment was attained with 2.97 ± 0.04 and 4.18 ± 0.05 V/cm with biphasic and monophasic pulses, respectively; p< 0.05). Thus, the association of automatic multidirectional stimulation and biphasic waveform enabled a 50% reduction of the absolute E value (3.8 vs. 7.8 V/cm with unidirectional stimulation and monopolar pulse) to evoke excitation in ~80% of the cells. The application of these procedures to cardiac stimulation (pacemaker and defibrillation) might optimize the process, leading to greater efficiency and lower injury incidence. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
29

Avaliação de dessincronia atrioventricular em portadores de marca-passo bicameral devido à doença do nó sinusal e bloqueio atrioventricular de primeiro grau / Evaluation of atrioventricular dyssynchrony in patients with dual-chamber pacemaker implanted due to sinus node disease and first degree atrioventricular block

Andres Di Leoni Ferrari 18 May 2017 (has links)
INTRODUÇÃO: O intervalo PR longo, em conjunto com a duração e a morfologia do QRS gerado pela estimulação cardíaca artificial, associam-se com dessincronia e disfunção cardíaca em diferentes níveis. Na doença do nó sinusal, durante a programação do marca-passo, podemos optar por duas estratégias: PR longo com QRS estreito (quando se busca evitar a ativação ventricular em detrimento do sincronismo atrioventricular) ou PR otimizado e QRS largo estimulado pelo marca-passo (quando se busca corrigir o intervalo atrioventricular em detrimento da sincronia ventricular). Neste estudo, buscamos comparar a evolução clínica e estrutural cardíaca destas estratégias. MÉTODOS: Acompanhou-se por 1 ano uma coorte com doença do nó sinusal, bloqueio atrioventricular de 1º grau (doença binodal) e marca-passo DDD. Através da ecocardiografia Doppler de fluxo transmitral avaliou-se a duração do enchimento diastólico ventricular e sincronia atrioventricular (? ondas E+A>=40% do ciclo cardíaco). Os pacientes dessincrônicos (DAV) tiveram o intervalo atrioventricular otimizado (intervenção) ao melhor rendimento hemodinâmico, porém com QRS estimulado. Estes retornavam ao PR basal após 6 meses (cross-over). Os sincrônicos (SAV) foram mantidos sob PR longo e QRS intrínseco durante todo o seguimento (controles). RESULTADOS: Quarenta e três pacientes foram incluídos e 41 completaram o estudo (idade média= 71,5 anos). Confirmou-se a existência dos 2 grupos (p= <0.001): os SAV (n=19), distintos daqueles com dessincronia atrioventricular (DAV, n=24). PR>=263ms mostrou especificidade de 78,9% para diagnóstico de dessincronia AV, e a maior duração do PR mostrou relação direta com pior função sistólica ventricular basal. Os DAV eram predominantemente homens, tinham PR mais longos (média= 283,5ms) e menor duração da diástole (p= 0.032). Um subgrupo dos DAV com PR >300ms mostrou pior qualidade de vida, maior duração do QRS quando estimulado, e dessincronia não corrigível por otimização. De modo notável, em 6 meses, o grupo DAV mostrou tendência a melhora da FEVE apesar do QRS alargado, e decréscimo ao retornar ao basal. O grupo SAV apresentava PR longo antifisiológico e evolutivamente piora da regurgitação mitral (p= 0.008) e também registros de fibrilação atrial de aparição mais precoce. Foram preditores independentes de dessincronia atrioventricular o PR >263ms (RR= 1,84; p= 0.024) e a duração da diástole inferior a 40% do ciclo cardíaco (RR= 0,99; p<0.001). CONCLUSÕES: Em pacientes com doença binodal e marca-passo DDD, a mera intenção de evitar o QRS largo da estimulação ventricular artificial não resolve todos os problemas. Intervalos PR longos (>263ms) associados ao decréscimo do enchimento diastólico ventricular caracterizariam outro prejuízo eletromecânico cardíaco: a dessincronia atrioventricular, disfunção que tem repercussão hemodinâmica, clínica e estrutural. / BACKGROUND: Long PR interval and wide QRS duration duo to ectopic morphology generated by artificial cardiac pacing are associated with cardiac dysfunction and dyssynchrony at different levels. When programming a permanent pacemaker in sinus node disease, two strategies can be considered: long PR with narrow QRS (avoiding ventricular pacing despite the risk of losing atrioventricular syncrony) or optimized PR interval with pacemaker-induced wide QRS (aiming to correct the atrioventricular delay despite loss of the ventricular synchrony). In this study, we aimed to compare the clinical and cardiac structural outcomes of these two strategies. METHODS: Sudy a cohort of patients with sinus node disease, first-degree AV block (binodal disease) and DDD pacemaker was followed for 1 year follow-up. atrioventrucular synchrony (AVS) was assessed echocardiographically by the ventricular diastolic filling time on Doppler transmitral flow: sum of the duration of E and A waves >=40% of the cardiac cycle. Patients with AV dyssynchrony (AVD) had the AV delay optimized (intervention group) for the best hemodynamic performance, but under wide artificially paced QRS. These returned to baseline PR interval after 6 months (cross-over). Those with AVS were kept under intrinsic QRS throughout the follow-up period despiste long PR interval (control group). RESULTS: Forty-three patients were included (mean age = 71.5 years), and 41 completed the 1-year follow-up. The existence of the 2 groups was confirmed (p<=0.001): patients with AVS (n=19), differed from those with AVD (n=24). Within a homogeneous sample (mean age= 71.5 years), PR >=263 ms had a specificity of 78.9% for the diagnosis of AVD, and longer PR intervals were associated with worse baseline ventricular systolic function. Most patients with AVD were men, had longer PR intervals (mean= 283.5 ms), and had significantly lower diastole duration (p= 0.032). A subgroup of AVD patients with PR >300 ms had poorer quality of life, significantly greater use of ?-blockers (p= 0.011), longer paced QRS width, and AV dyssynchrony that is non-correctable by optimization. Notably, at 6 months, the AVD group lean towards to have better LVEF values despite the wide QRS and a decrease when returning to baseline. Patients with AVS also had PR intervals different from the physiological condition (157.9 to 330 ms) and, over time, had worsening of mitral regurgitation (p=0.008) and earlier atrial fibrillation. PR>263 ms (RR= 1.84; p= 0.024) and diastole duration <40% of the cardiac cycle (RR= 0.99; p<0.001) were independent predictors of AVD. CONCLUSIONS: For patients with binodal disease and DDD pacemaker, the strategy of avoiding the wide QRS, usually applied by modern algorithms for minimizing ventricular pacing, is not enough to solve all problems. Long PR intervals (>=263 ms) may be associated with decreased ventricular diastolic filling time and characterize another cardiac electromechanical impairment: AV dyssynchrony, with hemodynamic, clinical and structural repercussions by itself.
30

The Effects of Spatial and Temporal Properties on a Viscoelastic Model of the Dyssynchronous Canine Heart

Satterlee, Cody Michael January 2011 (has links)
In this study, lumped parameter cardiovascular modeling has been used to understand the influence of muscle properties on mechanical dyssynchrony (MD) as well as general muscle dynamics. Incorporating viscous influence into the model allowed for an expanded view when analyzing muscle parameter response to MD. A unique method of ventricle segmentation was introduced that allowed fast analysis of regional and global ventricular properties. This segmentation process produced a ventricle with four identical sections each consisting of separately tunable muscle properties in the form of minimum and maximum elastance, elastance waveform delay, and myocardial viscous friction, yet these regional sections remained globally dependent. Elastance waveform delay proved to be the most influential property on MD as measured by internal flow fraction (IFF), followed by regional elastance magnitude, and finally regional viscosity influence. Due to the unique segmentation of this model, two metrics for IFF were derived: (1) the "true" IFF (IFF-4seg) and (2) the IFF as would be measured by an ideal conductance catheter (IFF-CC). The results of IFF-CC versus IFF-4seg show that conductance catheters are not capable of measuring IFF during a side-to-side volume transfer within the stacked cylinder under measurement. Finally, unique energetic situations were observed with this model that point to likely myocardium remodeling situations.

Page generated in 0.0877 seconds