• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 18
  • 2
  • 1
  • Tagged with
  • 48
  • 48
  • 29
  • 18
  • 17
  • 16
  • 11
  • 10
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Mechanismy adaptace hemodynamiky při uplatnění perkutánní venoarteriální mimotělní podpory oběhu u srdečního selhání / Hemodynamic adaptation mechanisms of heart failure to percutaneous venoarterial extracorporeal circulatory support

Hála, Pavel January 2020 (has links)
Introduction: Venoarterial extracorporeal membrane oxygenation (VA ECMO) is widely used in the treatment of circulatory failure, but repeatedly, its negative effects on the left ventricle (LV) have been observed. The purpose of this study is to assess the influence of ex- tracorporeal blood flow (EBF) on systemic hemodynamic changes and LV performance parameters during VA ECMO therapy of decompensated heart failure. Methods: Porcine models of low-output chronic and acute heart failure were developed by long-term fast cardiac pacing and coronary hypoxemia, respectively. Profound signs of circulatory decompensation were defined by reduced cardiac output and tissue hypoperfusion. Sub- sequently, under total anesthesia and artificial ventilation, VA ECMO was introduced. LV performance and organ specific parameters were recorded at different levels of EBF using an LV pressure-volume loop analysis, arterial flow probes on carotid and subclavian arteries, and transcutaneous probes positioned to measure cerebral and forelimb regional tissue oxygen saturations. Results: Conditions of severely decompensated heart failure led to systemic hypotension, low tissue and mixed venous oxygen saturations, and increase in LV end-diastolic pressure. By increasing the EBF from minimal flow to 5 L/min, we observed a...
32

Qualidade e capacidade diagnóstica da imagem de ressonância magnética cardíaca de 1,5 Tesla em pacientes com cardioversor desfibrilador implantável condicional / Quality and diagnostic capacity of the 1.5 Tesla magnetic resonance imaging in patients with conditional implantable cardioverter defibrillator

Andrade, Veridiana Silva de 28 May 2019 (has links)
Introdução: A realização do exame de ressonância magnética (RM), classicamente contraindicada aos portadores de dispositivo cardíaco eletrônico implantável (DCEI), passou a ser factível com a introdução dos recentes dispositivos condicionais para RM. Estes demonstraram superior grau de segurança na realização da RM, mas pouco se sabe sobre a qualidade e a capacidade diagnóstica das imagens obtidas no exame. Estas podem ser distorcidas pela presença do DCEI, sobretudo no que se refere ao cardioversor desfibrilador implantável (CDI), cuja quantidade de material ferromagnético é relevante. Objetivo: avaliar a qualidade e a capacidade diagnóstica da imagem de da RM cardíaca de 1,5 Tesla em portadores de CDI condicional. Método: Estudo piloto incluindo portadores de CDI condicional submetidos a RMC prévia (RMC1). Todos os pacientes realizaram exame de RMC pós-implante (RMC2), com protocolo específico de sequências de pulso utilizadas para cineressonância, realce tardio, perfusão miocárdica, mapa T1, mapa de fluxo, avaliação anatômica e de edema miocárdico. Todos foram submetidos à avaliação eletrônica do CDI, pré e pós RMC2, que constou de: medida do limiar de estimulação e sensibilidade, da impedância dos cabos-eletrodo e de choque, assim como da carga da bateria. Três especialistas avaliaram a qualidade das imagens de RMC, pré e pós-implante do CDI, que foram pontuadas por Escala de Likert. Esta gradua de 1 a 5 o impacto do artefato de imagem e a capacidade diagnóstica do exame. Para as imagens obtidas por múltiplos cortes a mesma pontuação foi utilizada para cada segmento do VE (segmentação da American Heart Association - AHA). A capacidade diagnóstica foi expressa, em percentual, pela taxa diagnóstica (sendo considerada diagnóstica pontuação maior ou igual a 3). Resultados: Foram estudados 22 pacientes submetidos a implante CDI condicional no período de agosto/2016 a abril/2018. Todas as imagens da RMC1 tiveram alta pontuação (3 a 5, m= 4,7) na escala de Likert. Por outro lado, em todos os exames da RMC2 ocorreram artefatos de suscetibilidade, sendo que as paredes anterior e lateral do VE foram mais afetadas. A pontuação média segmentar e respectivas taxas de imagens diagnósticas foram: 3,1 pontos e 82,32% para CINE SSFP; 1,74 e 27,80% para RT; 2,08 e 30,4% para perfusão miocárdica. As taxas de imagens diagnósticas obtidas nas aquisições por corte único foram: 0% para o mapa T1; 77,3% para avaliação anatômica (double e triple anatômico); 68,2% mapa de fluxo e 9,0% para avaliação do edema. Conclusão: Em portadores de CDI condicional, a qualidade das imagens e a capacidade diagnóstica do exame de RMC estão comprometidas por artefatos de suscetibilidade, presentes, sobretudo, nas paredes anterior e lateral de VE. Em particular a técnica de realce tardio, uma das mais importantes na RMC para diagnóstico de cardiomiopatias, demonstrou reduzida taxa diagnóstica, apontando a necessidade de novas técnicas para a detecção de fibrose/lesão miocárdica pela RMC. De forma geral, esses achados sugerem que é necessário realizar investigações adicionais, visando otimizar qualidade de imagem e capacidade diagnóstica da RMC nos portadores de CDI condicional / Introduction: Magnetic resonance imaging (MRI), which is classically contraindicated in patients with cardiac implantable electronic device (CIED), became feasible with the introduction of the recent MRI conditional devices. These have been proven to be safer, but little is known about the quality and diagnostic capacity of the acquired images, which can be distorted by the presence of CIED, especially with regard to the implantable cardioverter defibrillator (ICD), whose quantity of ferromagnetic material is relevant. Objective: to evaluate the quality and diagnostic value of the images acquired by cardiac MR in patients with conditional ICD. Method: Pilot study of patients with MR conditional ICD who were submitted to previous CMR (CMR1). All patients underwent an another CMR after ICD implantation (CMR2), under specific protocol of pulse sequences used for cine-resonance, late enhancement, myocardial perfusion, T1 mapping, anatomic and myocardial edema evaluation, and flow map. All patients underwent ICD electronic interrogations, immediate pre and post CMR2 measurements of battery voltage, capture thresholds, sensing, lead and shock impedance. Three specialists evaluated the quality of CMR images, pre and post implantation of ICD, which were scored by the Likert Scale. This graded measure from 1 to 5 the impact of the imaging artifact and the diagnostic ability of the examination. For the images acquired by multiple slices the same score was used for each left ventricule (LV) segment (American Heart Association - AHA criteria). Results: We studied 22 patients submitted to MR conditional ICD implantation. CMR1 had a high score (3 to 5, m = 4.7) on the Likert scale. On the other hand, in all CMR2 exams, there were artifacts of susceptibility, and the anterior and lateral LV walls were more affected. The mean segmental score and respective diagnostic image rates were: 3.1 points and 82.32% for Cine SSFP; 1.74 and 27.80% for LGE; 2.08 and 30,4% for myocardial perfusion. The rates of diagnostic images obtained in the single slice acquisition were 0% for T1 mapping; 77.3% for anatomical evaluation (double and triple anatomic); 68.2% for flow map and 9.0% for myocardial edema evaluation. Conclusion: In patients with MR conditional ICD, the quality of the images and the diagnostic capacity of the CMR examination are compromised by susceptibility artifacts, present mainly in the anterior and lateral LV walls. These findings suggest that further research is needed to optimize image quality and diagnostic capacity of CMR in patients with MR conditional ICD
33

Estudo clínico randomizado para profilaxia das complicações tromboembólicas pós-implante transvenoso de dispositivos cardíacos eletrônicos em pacientes de alto risco / Randomized controlled clinical trial for the prevention of thromboembolic complications after transvenous cardiac devices implantation in high risk patients

Silva, Katia Regina da 11 July 2008 (has links)
I ntrodução: A incidência de lesões venosas pós-implante transvenoso de dispositivos cardíacos eletrônicos implantáveis (DCEI) é elevada, sendo a disfunção ventricular e o uso prévio de marcapasso temporário (MPT) ipsilateral ao implante definitivo fatores de risco independentes para sua ocorrência. A utilidade de estratégias terapêuticas profiláticas para a prevenção dessa complicação ainda permanece controversa. O objetivo desse estudo clínico, randomizado e controlado foi avaliar o papel da anticoagulação oral na prevenção das lesões venosas pós-implante transvenoso de DCEI em pacientes de alto risco, analisando a influência na incidência das obstruções venosas, a segurança, a eficácia e as complicações do tratamento. Método: No período de Fevereiro/2004 a Setembro/2007 foram estudados 101 pacientes adultos submetidos ao primeiro implante transvenoso de DCEI, apresentando fração de ejeção do ventrículo esquerdo (FEVE) <=0,40 e/ou presença de MPT ipsilateral ao implante definitivo. Após o procedimento, os pacientes foram randomizados para o uso diário de placebo ou varfarina. Avaliações clínicas e laboratoriais foram realizadas periodicamente. A pesquisa de lesões venosas foi feita pela venografia por subtração digital, seis meses após o implante. A análise dos dados foi realizada segundo o princípio de \"intenção-de-tratar\". Na análise da associação das variáveis demográficas, clínicas e operatórias com a presença de lesões venosas empregou-se os testes Qui-quadrado, Exato de Fisher ou \"t\" de Student e o modelo de regressão logística foi utilizado para a identificação de fatores de risco. Resultados: As características basais foram similares nos dois grupos, não sendo encontradas diferenças significativas entre as variáveis demográficas, clínicas e operatórias. Durante o período de seguimento clínico, ocorreram seis óbitos, quatro relacionados com a progressão da insuficiência cardíaca e duas mortes súbitas. Do total de óbitos, quatro pacientes estavam alocados no Grupo Varfarina e dois no Placebo. Somente um paciente, do Grupo Varfarina, apresentou sangramento gastrintestinal, com necessidade de hospitalização e transfusão de hemoderivados. O valor médio do INR dos pacientes do Grupo Varfarina foi 2,3±0,7 enquanto que no Grupo Placebo foi 1,1±0,3, sendo que esta diferença manteve-se ao longo de todo o período de seguimento. O valor médio da hemoglobina e do hematócrito foi similar em ambos os grupos, sendo 13,9±1,6g/dL e 41,2±4,6%, no Grupo Placebo e 14,0±1,4g/dL e 41,9±3,7%, no Grupo Varfarina. Dos pacientes alocados no Grupo Varfarina, 17 (38,6%) apresentaram obstruções venosas, em comparação a 29 (60,4%) casos do Grupo Placebo, com redução absoluta do risco de 22% (RR= 0,63; IC 95%= 0,013 a 0,42). A comparação das características clínicas dos pacientes que apresentaram lesões venosas com as dos pacientes que não apresentaram mostrou que o uso de varfarina (P=0,037) esteve associado a uma menor incidência de lesões venosas e a presença da doença de Chagas (P= 0,051) esteve associada a uma maior incidência. Somente a ausência de anticoagulação oral foi identificada como fator de risco independente para a ocorrência das lesões venosas (OR= 2,424; IC 95% 1,048 - 5,606; P= 0,038). Conclusão: O uso profilático da anticoagulação mostrou-se seguro e reduziu significativamente a incidência de obstruções venosas pós-implante de DCEI nos pacientes de alto risco. / Introduction: The incidence of venous thrombosis after cardiac devices implantation is high. Ventricular dysfunction and previous transvenous temporary leads ipsilaterally to the permanent implantation are independent risk factors. The effect of prophylactic strategies to prevent these complications remains controversial. The aim of this clinical, randomized and controlled study was to evaluate the role of oral anticoagulant therapy in the prevention of these complications in high risk patients, analyzing the effect on the venous obstructions incidence, the safety, effectiveness and complications of this treatment. Method: Between February 2004 and September 2007, 101 adult patients submitted to first transvenous cardiac devices implantation, with left ventricular ejection fraction <=0.40 and/or previous transvenous temporary leads were evaluated. After device implantation, patients were randomly assigned to receive either placebo or warfarin. Periodical clinical and laboratorial evaluations were performed to anticoagulant management. Following the six-month period, every patient was submitted to a digital subtraction venography. Data analysis was performed according to the \"intention-to-treat\" principle. The association of demographic, clinical and procedure variables with the presence of venous lesions was analyzed by the Chi-square, Fisher\'s exact, or \"t\" Student tests, and logistic regression model was used to identify risk factors. Results: Baseline characteristics were similar in both groups and no significant difference was observed in demographic, clinical and procedure variables. During the follow-up period, six patients died, four related to heart failure progression and two of sudden death. Four of the patients dead were allocated in Warfarin group and two in Placebo group. Only one patient of the Warfarin group presented with gastrointestinal bleeding, requiring hospitalization and blood transfusion. The median INR of patients in the Warfarin group was 2.3 ± 0.7, whereas the median INR in the Placebo group was 1.1 ± 0.3. This difference was maintained throughout the study period. The median hemoglobin and hematocrit values were similar in both groups, with 13.9 ± 1.6g / dL and 41.2 ± 4.6% in the Placebo group and 14.0 ± 1.4g / dL and 41.9 ± 3.7% in the Warfarin group. The frequency of venous obstructions in the Warfarin group was 38.6% compared with 60.4% in the Placebo group (P=0.018), corresponding to an absolute risk reduction of 22% (RR= 0.63, 95% CI= 0.013-0.42). The comparison between obstructed and non-obstructed patients showed that warfarin use was associated with a lower incidence of venous lesions (P= 0.037) and that Chagas\' disease presence was associated with a higher incidence (P= 0.051). Logistic regression analysis showed that only absence of anticoagulant therapy (P=0.038; OR=2.424, 95% CI= 1.048 - 5.606) was a predictor of venous obstruction. Conclusion: The prophylactic use of the anticoagulation therapy has been safe and reduced the frequency of venous thrombosis after transvenous cardiac devices implantation in high risk patients.
34

"Estudo dos efeitos da estimulação atrial temporária na prevenção da fibrilação atrial no pós-operatório de cirurgia de revascularização do miocárdio com circulação extracorpórea" / Study the effect of temporary atrial pacing in prevention of atrial fibrillation after coronary artery bypass graft surgery

Avila Neto, Vicente 12 June 2006 (has links)
Avaliamos os efeitos da estimulação atrial temporária na prevenção da fibrilação atrial no pós-operatório de revascularização do miocárdio com circulação extracorpórea e identificamos os fatores de risco para o aparecimento dessa arritmia. Estudamos 240 pacientes que ao término da cirurgia de revascularização miocárdica submeteram-se ao implante de eletrodos epicárdicos na parede lateral do átrio direito e no teto do átrio esquerdo e foram randomizados em grupo não estimulado, grupo com estímulo atrial direito e grupo com estímulo simultâneo nos átrios direito e esquerdo. Concluímos que a estimulação atrial temporária reduziu a incidência de fibrilação atrial pós-operatória e que a idade avançada e a não estimulação atrial foram fatores preditivos independentes para a ocorrência da arritmia / We studied the effects of temporary atrial pacing to prevent the atrial fibrillation after coronary artery bypass graft surgery and the risk factors to occurrence of this arrhytmia. We followed-up 240 patients after coronary artery bypass graft surgery who suffered temporary pacing atrial implantation at the end of operation. The patients were randomized into three groups according pacing stimulation into right atrial pacing, biatrial pacing and no stimulated patients. We concluded that the temporary atrial pacing reduced the incidence of postoperative atrial fibrillation. In addition older age was also a predictive factor of occurrence of atrial fibrillation
35

Efeitos da terapia de ressincronização cardíaca no remodelamento ventricular reverso de pacientes com cardiopatia dilatada não isquêmica: avaliação pela ecocardiografia tridimensional / Effects of cardiac resynchronization therapy on left ventricular reverse remodeling in patients with non ischemic dilated myocardiopathy: evaluation by three dimensional echocardiography

Hotta, Viviane Tiemi 18 June 2010 (has links)
Introdução: A terapia de ressincronização cardíaca (TRC) tem se mostrado como um tratamento eficaz no tratamento de pacientes com insuficiência cardíaca (IC) grave e distúrbio da condução ventricular. A ecocardiografia tridimensional (Eco 3D) consiste em uma nova modalidade diagnóstica com resultados promissores para a identificação da dissincronia cardíaca e avaliação dos resultados da TRC. Objetivos: Estudar os efeitos da TRC no remodelamento reverso do ventrículo esquerdo (VE), em pacientes com miocardiopatia não isquêmica, insuficiência cardíaca e distúrbio da condução intraventricular, por meio da ecocardiografia tridimensional em tempo real. Métodos: De janeiro de 2007 a junho de 2009, foram avaliados 24 pacientes com miocardiopatia dilatada não isquêmica, IC classe funcional (CF) III ou IV (NYHA), com tratamento medicamentoso otimizado, QRS > 120 ms ao eletrocardiograma, e fração de ejeção do ventrículo esquerdo (FEVE) < 0,35 submetidos à TRC. Os pacientes foram avaliados antes, três e seis meses após TRC pela CF (NYHA), qualidade de vida pelo escore de Minnesota (MLHFQ), eletrocardiograma (intervalo PR e duração do QRS), ecocardiograma bidimensional (volumes diastólico VDVE, e sistólico VSVE, do ventrículo esquerdo, fração de ejeção ventricular esquerda - FEVE), Doppler tecidual (TDI) (avaliação da dissincronia cardíaca) e análise tridimensional (VDVE, VSVE, FEVE e dissincronia pela análise do SDI systolic dyssynchrony index). Foi considerado remodelamento reverso redução > 15% do VSVE após a TRC. As diferenças das médias das variáveis contínuas foram analisadas com o teste T não pareado, entre os grupos respondedor e não respondedor, depois de satisfeita a condição de normalidade. Antes da TRC, foi realizada uma análise univariada das características clínicas, eletrocardiográficas e ecocardiográficas para a construção de um modelo de regressão logística. Resultados: 9/24(38%) dos pacientes analisados apresentaram remodelamento ventricular reverso após TRC. O grupo respondedor apresentou menores volumes ventriculares (VDVE: 230 + 35 ml vs 316 + 10 ml, p = 0,045; VSVE: 178 + 30 ml vs 238 + 10 ml, p = 0,047), avaliados pelo método de Simpson, além de maior dissincronia cardíaca, avaliada pelo Eco 3D (SDI:13 + 3% vs 9 + 3%, p = 0,005) e pelo TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). Após a análise de regressão logística, o SDI (SDI > 11%) foi o único fator independente na predição de remodelamento reverso, seis meses após a TRC (sensibilidade:0,78; especificidade:0,79). Conclusões: O Eco 3D foi eficaz na detecção do remodelamento reverso do VE após a TRC, por meio da detecção da redução dos volumes ventriculares esquerdos (VDVE, VSVE) e da melhora da FEVE. O SDI foi o único preditor independente de remodelamento reverso após a TRC. Apresentaram menor taxa de resposta seis meses após a TRC, os pacientes com maiores volumes ventriculares esquerdos e menor fração de ejeção ventricular esquerda. A TRC melhorou a CF (NYHA) de IC e a qualidade de vida pelo escore de Minnesota / Introduction: Cardiac resynchronization therapy (CRT) consists of an effective treatment for patients with severe heart failure and ventricular conduction disturbance. Three dimensional echocardiography (3D Echo) is a new diagnostic modality with promising results in the identification of cardiac dyssynchrony and for the evaluation of CRT results. Objectives: To evaluate the effects of CRT in the left ventricular (LV) reverse remodeling in patients with non ischemic dilated myocardiopathy, heart failure and intraventricular conduction disturbance by using three dimensional echocardiography. Methods: From January, 2007 to June, 2009, twenty-four consecutive patients with heart failure, sinus rhythm, QRS > 120 ms, and Functional Class III or IV (NYHA), despite optimized medical treatment and left ventricular ejection fraction (LVEF) < 0,35, underwent CRT. All patients were assessed regarding Functional Class (NYHA), and the quality of life was evaluated using the Minnesota Living with Heart Failure Questionnaire (MLHFQ). All patients were submitted to an electrocardiogram, two dimensional echocardiography (2D Echo) including the evaluation of cardiac dyssynchrony by Tissue Doppler Imaging (TDI) and 3D Echo (SDI - systolic dyssynchrony index), before, three and six months after CRT. Left ventricular reverse remodeling was defined as a reduction of at least 15% of the left ventricular systolic volume (LVSV) after CRT. The difference between the mean of the continuous variables were compared by students T test, after being tested for normality. Before CRT, it was performed a univariate analysis of clinical, electrocardiographic and echocardiographic baseline characteristics of the patients for the construction of a logistic regression model. Results: 9/24 (38%) of the patients presented with left ventricular reverse remodeling six months after CRT. Patients who presented LV reverse remodeling had smaller left ventricular volumes estimated by Simpsons rule (LV diastolic volume (LVDV): 230 + 35 ml vs 316 + 10 ml, p = 0,045; LVSV: 178 + 30 ml vs 238 + 10 ml, p = 0,047) and greater cardiac dyssynchrony detected by 3D Echo (SDI: 13 + 3% vs 9 + 3%, p = 0,005) and by TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). After logistic regression analysis, the best predictors of left ventricular reverse remodeling after CRT were the cardiac dyssynchrony indexes evaluated by TDI (twelve segments) and SDI, but SDI (SDI > 11%) was the only independent factor in the prediction of left ventricular reverse remodeling six months after CRT (sensitivity of 0,78 and specificity of 0,79). Conclusions: 3D Echo was effective in the detection of left ventricular reverse remodeling after CRT, by detecting the reduction in left ventricular volumes (LVDV, LVSV) and the increase in LVEF. SDI was the only independent predictor of LV reverse remodeling after CRT. Patients with larger LV volumes, and smaller LVEF were more prone to not respond six months after CRT. CRT improved Functional Class (NYHA) and quality of life evaluated by MLHFQ
36

MRI methods for predicting response to cardiac resynchronization therapy

Suever, Jonathan D. 13 January 2014 (has links)
Cardiac Resynchronization Therapy (CRT) is a treatment option for heart failure patients with ventricular dyssynchrony. CRT corrects for dyssynchrony by electrically stimulating the septal and lateral walls of the left ventricle (LV), forcing synchronous con- traction and improving cardiac output. Current selection criteria for CRT rely upon the QRS duration, measured from a surface electrocardiogram, as a marker of electrical dyssynchrony. Unfortunately, 30-40% of patients undergoing CRT fail to benefit from the treatment. A multitude of studies have shown that presence of mechanical dyssynchrony in the LV is an important factor in determining if a patient will benefit from CRT. Furthermore, recent evidence suggests that patient response can be improved by placing the LV pacing lead in the most dyssynchronous or latest contracting segment. The overall goal of this project was to develop methods that allow for accurate assessment and display of regional mechanical dyssynchrony throughout the LV and at the site of the LV pacing lead. To accomplish this goal, we developed a method for quantifying regional dyssynchrony from standard short-axis cine magnetic resonance (MR) images. To assess the effects of LV lead placement, we developed a registration method that allows us to project the LV lead location from dual-plane fluoroscopy onto MR measurements of cardiac function. By applying these techniques in patients undergoing CRT, we were able to investigate the relationship between regional dyssynchrony, LV pacing lead location, and CRT response.
37

Estudo clínico randomizado para profilaxia das complicações tromboembólicas pós-implante transvenoso de dispositivos cardíacos eletrônicos em pacientes de alto risco / Randomized controlled clinical trial for the prevention of thromboembolic complications after transvenous cardiac devices implantation in high risk patients

Katia Regina da Silva 11 July 2008 (has links)
I ntrodução: A incidência de lesões venosas pós-implante transvenoso de dispositivos cardíacos eletrônicos implantáveis (DCEI) é elevada, sendo a disfunção ventricular e o uso prévio de marcapasso temporário (MPT) ipsilateral ao implante definitivo fatores de risco independentes para sua ocorrência. A utilidade de estratégias terapêuticas profiláticas para a prevenção dessa complicação ainda permanece controversa. O objetivo desse estudo clínico, randomizado e controlado foi avaliar o papel da anticoagulação oral na prevenção das lesões venosas pós-implante transvenoso de DCEI em pacientes de alto risco, analisando a influência na incidência das obstruções venosas, a segurança, a eficácia e as complicações do tratamento. Método: No período de Fevereiro/2004 a Setembro/2007 foram estudados 101 pacientes adultos submetidos ao primeiro implante transvenoso de DCEI, apresentando fração de ejeção do ventrículo esquerdo (FEVE) <=0,40 e/ou presença de MPT ipsilateral ao implante definitivo. Após o procedimento, os pacientes foram randomizados para o uso diário de placebo ou varfarina. Avaliações clínicas e laboratoriais foram realizadas periodicamente. A pesquisa de lesões venosas foi feita pela venografia por subtração digital, seis meses após o implante. A análise dos dados foi realizada segundo o princípio de \"intenção-de-tratar\". Na análise da associação das variáveis demográficas, clínicas e operatórias com a presença de lesões venosas empregou-se os testes Qui-quadrado, Exato de Fisher ou \"t\" de Student e o modelo de regressão logística foi utilizado para a identificação de fatores de risco. Resultados: As características basais foram similares nos dois grupos, não sendo encontradas diferenças significativas entre as variáveis demográficas, clínicas e operatórias. Durante o período de seguimento clínico, ocorreram seis óbitos, quatro relacionados com a progressão da insuficiência cardíaca e duas mortes súbitas. Do total de óbitos, quatro pacientes estavam alocados no Grupo Varfarina e dois no Placebo. Somente um paciente, do Grupo Varfarina, apresentou sangramento gastrintestinal, com necessidade de hospitalização e transfusão de hemoderivados. O valor médio do INR dos pacientes do Grupo Varfarina foi 2,3±0,7 enquanto que no Grupo Placebo foi 1,1±0,3, sendo que esta diferença manteve-se ao longo de todo o período de seguimento. O valor médio da hemoglobina e do hematócrito foi similar em ambos os grupos, sendo 13,9±1,6g/dL e 41,2±4,6%, no Grupo Placebo e 14,0±1,4g/dL e 41,9±3,7%, no Grupo Varfarina. Dos pacientes alocados no Grupo Varfarina, 17 (38,6%) apresentaram obstruções venosas, em comparação a 29 (60,4%) casos do Grupo Placebo, com redução absoluta do risco de 22% (RR= 0,63; IC 95%= 0,013 a 0,42). A comparação das características clínicas dos pacientes que apresentaram lesões venosas com as dos pacientes que não apresentaram mostrou que o uso de varfarina (P=0,037) esteve associado a uma menor incidência de lesões venosas e a presença da doença de Chagas (P= 0,051) esteve associada a uma maior incidência. Somente a ausência de anticoagulação oral foi identificada como fator de risco independente para a ocorrência das lesões venosas (OR= 2,424; IC 95% 1,048 - 5,606; P= 0,038). Conclusão: O uso profilático da anticoagulação mostrou-se seguro e reduziu significativamente a incidência de obstruções venosas pós-implante de DCEI nos pacientes de alto risco. / Introduction: The incidence of venous thrombosis after cardiac devices implantation is high. Ventricular dysfunction and previous transvenous temporary leads ipsilaterally to the permanent implantation are independent risk factors. The effect of prophylactic strategies to prevent these complications remains controversial. The aim of this clinical, randomized and controlled study was to evaluate the role of oral anticoagulant therapy in the prevention of these complications in high risk patients, analyzing the effect on the venous obstructions incidence, the safety, effectiveness and complications of this treatment. Method: Between February 2004 and September 2007, 101 adult patients submitted to first transvenous cardiac devices implantation, with left ventricular ejection fraction <=0.40 and/or previous transvenous temporary leads were evaluated. After device implantation, patients were randomly assigned to receive either placebo or warfarin. Periodical clinical and laboratorial evaluations were performed to anticoagulant management. Following the six-month period, every patient was submitted to a digital subtraction venography. Data analysis was performed according to the \"intention-to-treat\" principle. The association of demographic, clinical and procedure variables with the presence of venous lesions was analyzed by the Chi-square, Fisher\'s exact, or \"t\" Student tests, and logistic regression model was used to identify risk factors. Results: Baseline characteristics were similar in both groups and no significant difference was observed in demographic, clinical and procedure variables. During the follow-up period, six patients died, four related to heart failure progression and two of sudden death. Four of the patients dead were allocated in Warfarin group and two in Placebo group. Only one patient of the Warfarin group presented with gastrointestinal bleeding, requiring hospitalization and blood transfusion. The median INR of patients in the Warfarin group was 2.3 ± 0.7, whereas the median INR in the Placebo group was 1.1 ± 0.3. This difference was maintained throughout the study period. The median hemoglobin and hematocrit values were similar in both groups, with 13.9 ± 1.6g / dL and 41.2 ± 4.6% in the Placebo group and 14.0 ± 1.4g / dL and 41.9 ± 3.7% in the Warfarin group. The frequency of venous obstructions in the Warfarin group was 38.6% compared with 60.4% in the Placebo group (P=0.018), corresponding to an absolute risk reduction of 22% (RR= 0.63, 95% CI= 0.013-0.42). The comparison between obstructed and non-obstructed patients showed that warfarin use was associated with a lower incidence of venous lesions (P= 0.037) and that Chagas\' disease presence was associated with a higher incidence (P= 0.051). Logistic regression analysis showed that only absence of anticoagulant therapy (P=0.038; OR=2.424, 95% CI= 1.048 - 5.606) was a predictor of venous obstruction. Conclusion: The prophylactic use of the anticoagulation therapy has been safe and reduced the frequency of venous thrombosis after transvenous cardiac devices implantation in high risk patients.
38

Efeitos da terapia de ressincronização cardíaca no remodelamento ventricular reverso de pacientes com cardiopatia dilatada não isquêmica: avaliação pela ecocardiografia tridimensional / Effects of cardiac resynchronization therapy on left ventricular reverse remodeling in patients with non ischemic dilated myocardiopathy: evaluation by three dimensional echocardiography

Viviane Tiemi Hotta 18 June 2010 (has links)
Introdução: A terapia de ressincronização cardíaca (TRC) tem se mostrado como um tratamento eficaz no tratamento de pacientes com insuficiência cardíaca (IC) grave e distúrbio da condução ventricular. A ecocardiografia tridimensional (Eco 3D) consiste em uma nova modalidade diagnóstica com resultados promissores para a identificação da dissincronia cardíaca e avaliação dos resultados da TRC. Objetivos: Estudar os efeitos da TRC no remodelamento reverso do ventrículo esquerdo (VE), em pacientes com miocardiopatia não isquêmica, insuficiência cardíaca e distúrbio da condução intraventricular, por meio da ecocardiografia tridimensional em tempo real. Métodos: De janeiro de 2007 a junho de 2009, foram avaliados 24 pacientes com miocardiopatia dilatada não isquêmica, IC classe funcional (CF) III ou IV (NYHA), com tratamento medicamentoso otimizado, QRS > 120 ms ao eletrocardiograma, e fração de ejeção do ventrículo esquerdo (FEVE) < 0,35 submetidos à TRC. Os pacientes foram avaliados antes, três e seis meses após TRC pela CF (NYHA), qualidade de vida pelo escore de Minnesota (MLHFQ), eletrocardiograma (intervalo PR e duração do QRS), ecocardiograma bidimensional (volumes diastólico VDVE, e sistólico VSVE, do ventrículo esquerdo, fração de ejeção ventricular esquerda - FEVE), Doppler tecidual (TDI) (avaliação da dissincronia cardíaca) e análise tridimensional (VDVE, VSVE, FEVE e dissincronia pela análise do SDI systolic dyssynchrony index). Foi considerado remodelamento reverso redução > 15% do VSVE após a TRC. As diferenças das médias das variáveis contínuas foram analisadas com o teste T não pareado, entre os grupos respondedor e não respondedor, depois de satisfeita a condição de normalidade. Antes da TRC, foi realizada uma análise univariada das características clínicas, eletrocardiográficas e ecocardiográficas para a construção de um modelo de regressão logística. Resultados: 9/24(38%) dos pacientes analisados apresentaram remodelamento ventricular reverso após TRC. O grupo respondedor apresentou menores volumes ventriculares (VDVE: 230 + 35 ml vs 316 + 10 ml, p = 0,045; VSVE: 178 + 30 ml vs 238 + 10 ml, p = 0,047), avaliados pelo método de Simpson, além de maior dissincronia cardíaca, avaliada pelo Eco 3D (SDI:13 + 3% vs 9 + 3%, p = 0,005) e pelo TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). Após a análise de regressão logística, o SDI (SDI > 11%) foi o único fator independente na predição de remodelamento reverso, seis meses após a TRC (sensibilidade:0,78; especificidade:0,79). Conclusões: O Eco 3D foi eficaz na detecção do remodelamento reverso do VE após a TRC, por meio da detecção da redução dos volumes ventriculares esquerdos (VDVE, VSVE) e da melhora da FEVE. O SDI foi o único preditor independente de remodelamento reverso após a TRC. Apresentaram menor taxa de resposta seis meses após a TRC, os pacientes com maiores volumes ventriculares esquerdos e menor fração de ejeção ventricular esquerda. A TRC melhorou a CF (NYHA) de IC e a qualidade de vida pelo escore de Minnesota / Introduction: Cardiac resynchronization therapy (CRT) consists of an effective treatment for patients with severe heart failure and ventricular conduction disturbance. Three dimensional echocardiography (3D Echo) is a new diagnostic modality with promising results in the identification of cardiac dyssynchrony and for the evaluation of CRT results. Objectives: To evaluate the effects of CRT in the left ventricular (LV) reverse remodeling in patients with non ischemic dilated myocardiopathy, heart failure and intraventricular conduction disturbance by using three dimensional echocardiography. Methods: From January, 2007 to June, 2009, twenty-four consecutive patients with heart failure, sinus rhythm, QRS > 120 ms, and Functional Class III or IV (NYHA), despite optimized medical treatment and left ventricular ejection fraction (LVEF) < 0,35, underwent CRT. All patients were assessed regarding Functional Class (NYHA), and the quality of life was evaluated using the Minnesota Living with Heart Failure Questionnaire (MLHFQ). All patients were submitted to an electrocardiogram, two dimensional echocardiography (2D Echo) including the evaluation of cardiac dyssynchrony by Tissue Doppler Imaging (TDI) and 3D Echo (SDI - systolic dyssynchrony index), before, three and six months after CRT. Left ventricular reverse remodeling was defined as a reduction of at least 15% of the left ventricular systolic volume (LVSV) after CRT. The difference between the mean of the continuous variables were compared by students T test, after being tested for normality. Before CRT, it was performed a univariate analysis of clinical, electrocardiographic and echocardiographic baseline characteristics of the patients for the construction of a logistic regression model. Results: 9/24 (38%) of the patients presented with left ventricular reverse remodeling six months after CRT. Patients who presented LV reverse remodeling had smaller left ventricular volumes estimated by Simpsons rule (LV diastolic volume (LVDV): 230 + 35 ml vs 316 + 10 ml, p = 0,045; LVSV: 178 + 30 ml vs 238 + 10 ml, p = 0,047) and greater cardiac dyssynchrony detected by 3D Echo (SDI: 13 + 3% vs 9 + 3%, p = 0,005) and by TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). After logistic regression analysis, the best predictors of left ventricular reverse remodeling after CRT were the cardiac dyssynchrony indexes evaluated by TDI (twelve segments) and SDI, but SDI (SDI > 11%) was the only independent factor in the prediction of left ventricular reverse remodeling six months after CRT (sensitivity of 0,78 and specificity of 0,79). Conclusions: 3D Echo was effective in the detection of left ventricular reverse remodeling after CRT, by detecting the reduction in left ventricular volumes (LVDV, LVSV) and the increase in LVEF. SDI was the only independent predictor of LV reverse remodeling after CRT. Patients with larger LV volumes, and smaller LVEF were more prone to not respond six months after CRT. CRT improved Functional Class (NYHA) and quality of life evaluated by MLHFQ
39

Avaliação da qualidade de vida de portadores de marcapasso cardíaco artificial em Goiânia, Goiás / Quality of life of artificial cardiac pacemaker patient in Goiânia, Goiás

ZATTA, Laidilce Teles 14 April 2010 (has links)
Made available in DSpace on 2014-07-29T15:04:27Z (GMT). No. of bitstreams: 1 dissertacao Laidilce T Zatta.pdf: 353033 bytes, checksum: 50158c4aade92a4a9fe7e29429d42d86 (MD5) Previous issue date: 2010-04-14 / Health related quality of life includes social, emotional and physical well-being of individuals, the impact of some treatments used to control health problems and the individual's ability to lead his own life. One of these treatments currently used is a device called artificial pacemaker, and patients have reported changes in daily life after implantation, which may influence the quality of their lives. It is a descriptive exploratory study that aimed to evaluate the quality of life of cardiac pacemakers patients using a generic instrument- SF-36 ® (Medical Outcomes Study 36-Item Short-Form Health Survey) and other specific instrument - AQUAREL (Assessment of Quality of Life and Related Events). We interviewed 84 patients with permanent pacemaker after six or more months of implantation, and used two instruments to assess quality of life: SF-36 and AQUAREL. Respondents had an average age 59.9 years, 58.3% were female, catholic (70.2%), had completed elementary school (81%). They self-reported themselves as white (59.5%), they had a steady partner (69%) and monthly family income below two minimum wages (51.3%). The implantation time varied between one and 28 years (median three years), the principal cause was the Chagas disease (76.2%), 73.8% were with the first generator, the predominant type of stimulation was DDDR (67,9%) and they were functional class I (57.1%). The median scores for SF-36 dimensions were higher in Social Functioning (100.00) and Mental Health (68.00) dimensions; the lowest scores were obtained in Role Limitations Resulting from Physical Health (00.00) and Role Limitations Resulting from Emotional Problems (33.33) dimensions. The median scores of AQUAREL were 81.25 for Chest Discomfort, Arrhythmias (80.00) and 71.43 for Dyspnea. Cronbach's Alpha ranged between 0.916 and 0.688 for SF-36 dimensions and between 0.852 and 0.693 for AQUAREL, indicating good reliability of the instruments. It was observed that the perception of individuals facing the aspects analyzed in each dimension of SF-36 and AQUAREL is not homogeneous, being influenced by religion, gender, age, race, presence of children, work, income level, education, number of implants and the reason of the implant. The lower scores indicate which aspects need attention from the health team to contribute to the quality of life of these patients. / A qualidade de vida relacionada à saúde engloba, além dos aspectos sociais, emocionais e de bem-estar físico dos indivíduos, o impacto de alguns tratamentos empregados para controle de problemas de saúde e a habilidade do indivíduo de conduzir sua própria vida. Um dos tratamentos é o implante de marcapasso cardíaco artificial definitivo, cujos portadores relatam alterações na vida diária após o implante, que podem influenciar na qualidade de suas vidas. Trata-se de estudo descritivo exploratório, que objetivou avaliar a qualidade de vida dos portadores de marcapasso cardíaco artificial por meio de um instrumento genérico - SF-36® (Medical Outcomes Study 36-Item Short-Form Health Survey) e outro específico - AQUAREL (Assessment of Quality of Life and Related Events). Foram entrevistados 84 portadores de marcapasso cardíaco artificial definitivo após seis ou mais meses de implante. Os entrevistados tinham idade média de 59,9 anos, 58,3% eram do sexo feminino, católicos (70,2%), possuíam escolaridade fundamental incompleta (81%). Autodenominaram-se brancos (59,5%), possuíam companheiro fixo (69%) e renda mensal familiar inferior a dois salários mínimos (51,3%). O tempo de implante variou entre um e 28 anos (mediana três anos), a causa base foi a doença de Chagas (76,2%), 73,8% estavam com o 1º gerador, o tipo de estimulação predominante foi DDDR (67,9%) e pertenciam à classe funcional I (57,1%). As medianas dos escores do SF-36 foram maiores nas dimensões Aspectos Sociais (100,00) e Saúde Mental (68,00) e os menores escores foram obtidos em Aspectos Físicos (00,00) e Aspectos Emocionais (33,33). As medianas dos escores do AQUAREL foram 81,25 para Desconforto no Peito, 80,00 para Arritmias e 71,43 para Dispnéia ao Exercício. O alfa de Cronbach variou entre 0,916 e 0,688 para as dimensões do SF-36 e entre 0,852 e 0,693 para o AQUAREL, indicando boa confiabilidade dos instrumentos. Observou-se que a percepção dos indivíduos frente aos aspectos analisados em cada dimensão do SF-36 e AQUAREL não é homogênea, sendo influenciada pela religião, sexo, faixa etária, raça, presença ou não de filhos, trabalho, faixa de renda, escolaridade, número de implante e motivo do implante. Os menores escores indicam quais aspectos precisam de maior atenção por parte da equipe de saúde. Reforça-se a necessidade da atuação qualificada de uma equipe multiprofissional que acompanhe o portador de marcapasso, minimizando os fatores que possam estar interferindo na sua qualidade de vida.
40

"Estudo dos efeitos da estimulação atrial temporária na prevenção da fibrilação atrial no pós-operatório de cirurgia de revascularização do miocárdio com circulação extracorpórea" / Study the effect of temporary atrial pacing in prevention of atrial fibrillation after coronary artery bypass graft surgery

Vicente Avila Neto 12 June 2006 (has links)
Avaliamos os efeitos da estimulação atrial temporária na prevenção da fibrilação atrial no pós-operatório de revascularização do miocárdio com circulação extracorpórea e identificamos os fatores de risco para o aparecimento dessa arritmia. Estudamos 240 pacientes que ao término da cirurgia de revascularização miocárdica submeteram-se ao implante de eletrodos epicárdicos na parede lateral do átrio direito e no teto do átrio esquerdo e foram randomizados em grupo não estimulado, grupo com estímulo atrial direito e grupo com estímulo simultâneo nos átrios direito e esquerdo. Concluímos que a estimulação atrial temporária reduziu a incidência de fibrilação atrial pós-operatória e que a idade avançada e a não estimulação atrial foram fatores preditivos independentes para a ocorrência da arritmia / We studied the effects of temporary atrial pacing to prevent the atrial fibrillation after coronary artery bypass graft surgery and the risk factors to occurrence of this arrhytmia. We followed-up 240 patients after coronary artery bypass graft surgery who suffered temporary pacing atrial implantation at the end of operation. The patients were randomized into three groups according pacing stimulation into right atrial pacing, biatrial pacing and no stimulated patients. We concluded that the temporary atrial pacing reduced the incidence of postoperative atrial fibrillation. In addition older age was also a predictive factor of occurrence of atrial fibrillation

Page generated in 0.079 seconds