• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mechanismy adaptace hemodynamiky při uplatnění perkutánní venoarteriální mimotělní podpory oběhu u srdečního selhání / Hemodynamic adaptation mechanisms of heart failure to percutaneous venoarterial extracorporeal circulatory support

Hála, Pavel January 2020 (has links)
Introduction: Venoarterial extracorporeal membrane oxygenation (VA ECMO) is widely used in the treatment of circulatory failure, but repeatedly, its negative effects on the left ventricle (LV) have been observed. The purpose of this study is to assess the influence of ex- tracorporeal blood flow (EBF) on systemic hemodynamic changes and LV performance parameters during VA ECMO therapy of decompensated heart failure. Methods: Porcine models of low-output chronic and acute heart failure were developed by long-term fast cardiac pacing and coronary hypoxemia, respectively. Profound signs of circulatory decompensation were defined by reduced cardiac output and tissue hypoperfusion. Sub- sequently, under total anesthesia and artificial ventilation, VA ECMO was introduced. LV performance and organ specific parameters were recorded at different levels of EBF using an LV pressure-volume loop analysis, arterial flow probes on carotid and subclavian arteries, and transcutaneous probes positioned to measure cerebral and forelimb regional tissue oxygen saturations. Results: Conditions of severely decompensated heart failure led to systemic hypotension, low tissue and mixed venous oxygen saturations, and increase in LV end-diastolic pressure. By increasing the EBF from minimal flow to 5 L/min, we observed a...
2

Avaliação da qualidade de vida de portadores de marcapasso cardíaco artificial em Goiânia, Goiás / Quality of life of artificial cardiac pacemaker patient in Goiânia, Goiás

ZATTA, Laidilce Teles 14 April 2010 (has links)
Made available in DSpace on 2014-07-29T15:04:27Z (GMT). No. of bitstreams: 1 dissertacao Laidilce T Zatta.pdf: 353033 bytes, checksum: 50158c4aade92a4a9fe7e29429d42d86 (MD5) Previous issue date: 2010-04-14 / Health related quality of life includes social, emotional and physical well-being of individuals, the impact of some treatments used to control health problems and the individual's ability to lead his own life. One of these treatments currently used is a device called artificial pacemaker, and patients have reported changes in daily life after implantation, which may influence the quality of their lives. It is a descriptive exploratory study that aimed to evaluate the quality of life of cardiac pacemakers patients using a generic instrument- SF-36 ® (Medical Outcomes Study 36-Item Short-Form Health Survey) and other specific instrument - AQUAREL (Assessment of Quality of Life and Related Events). We interviewed 84 patients with permanent pacemaker after six or more months of implantation, and used two instruments to assess quality of life: SF-36 and AQUAREL. Respondents had an average age 59.9 years, 58.3% were female, catholic (70.2%), had completed elementary school (81%). They self-reported themselves as white (59.5%), they had a steady partner (69%) and monthly family income below two minimum wages (51.3%). The implantation time varied between one and 28 years (median three years), the principal cause was the Chagas disease (76.2%), 73.8% were with the first generator, the predominant type of stimulation was DDDR (67,9%) and they were functional class I (57.1%). The median scores for SF-36 dimensions were higher in Social Functioning (100.00) and Mental Health (68.00) dimensions; the lowest scores were obtained in Role Limitations Resulting from Physical Health (00.00) and Role Limitations Resulting from Emotional Problems (33.33) dimensions. The median scores of AQUAREL were 81.25 for Chest Discomfort, Arrhythmias (80.00) and 71.43 for Dyspnea. Cronbach's Alpha ranged between 0.916 and 0.688 for SF-36 dimensions and between 0.852 and 0.693 for AQUAREL, indicating good reliability of the instruments. It was observed that the perception of individuals facing the aspects analyzed in each dimension of SF-36 and AQUAREL is not homogeneous, being influenced by religion, gender, age, race, presence of children, work, income level, education, number of implants and the reason of the implant. The lower scores indicate which aspects need attention from the health team to contribute to the quality of life of these patients. / A qualidade de vida relacionada à saúde engloba, além dos aspectos sociais, emocionais e de bem-estar físico dos indivíduos, o impacto de alguns tratamentos empregados para controle de problemas de saúde e a habilidade do indivíduo de conduzir sua própria vida. Um dos tratamentos é o implante de marcapasso cardíaco artificial definitivo, cujos portadores relatam alterações na vida diária após o implante, que podem influenciar na qualidade de suas vidas. Trata-se de estudo descritivo exploratório, que objetivou avaliar a qualidade de vida dos portadores de marcapasso cardíaco artificial por meio de um instrumento genérico - SF-36® (Medical Outcomes Study 36-Item Short-Form Health Survey) e outro específico - AQUAREL (Assessment of Quality of Life and Related Events). Foram entrevistados 84 portadores de marcapasso cardíaco artificial definitivo após seis ou mais meses de implante. Os entrevistados tinham idade média de 59,9 anos, 58,3% eram do sexo feminino, católicos (70,2%), possuíam escolaridade fundamental incompleta (81%). Autodenominaram-se brancos (59,5%), possuíam companheiro fixo (69%) e renda mensal familiar inferior a dois salários mínimos (51,3%). O tempo de implante variou entre um e 28 anos (mediana três anos), a causa base foi a doença de Chagas (76,2%), 73,8% estavam com o 1º gerador, o tipo de estimulação predominante foi DDDR (67,9%) e pertenciam à classe funcional I (57,1%). As medianas dos escores do SF-36 foram maiores nas dimensões Aspectos Sociais (100,00) e Saúde Mental (68,00) e os menores escores foram obtidos em Aspectos Físicos (00,00) e Aspectos Emocionais (33,33). As medianas dos escores do AQUAREL foram 81,25 para Desconforto no Peito, 80,00 para Arritmias e 71,43 para Dispnéia ao Exercício. O alfa de Cronbach variou entre 0,916 e 0,688 para as dimensões do SF-36 e entre 0,852 e 0,693 para o AQUAREL, indicando boa confiabilidade dos instrumentos. Observou-se que a percepção dos indivíduos frente aos aspectos analisados em cada dimensão do SF-36 e AQUAREL não é homogênea, sendo influenciada pela religião, sexo, faixa etária, raça, presença ou não de filhos, trabalho, faixa de renda, escolaridade, número de implante e motivo do implante. Os menores escores indicam quais aspectos precisam de maior atenção por parte da equipe de saúde. Reforça-se a necessidade da atuação qualificada de uma equipe multiprofissional que acompanhe o portador de marcapasso, minimizando os fatores que possam estar interferindo na sua qualidade de vida.
3

Avaliação da estimulação ventricular direita crônica em crianças e adultos jovens com bloqueio atrioventricular congênito isolado / Evaluation of chronic right ventricular pacing in children and young adults with isolated congenital complete atrioventricular block

Oliveira Júnior, Roberto Marcio de 24 April 2014 (has links)
Introdução: O bloqueio atrioventricular congênito isolado (BAVCi) é raro e tem múltiplas apresentações clínicas. O implante de marca-passo cardíaco permanente (MP) é o tratamento de escolha, resultando em evolução clínica satisfatória para a maioria dos casos, porém, aproximadamente 10% deles apresentam remodelamento ventricular e insuficiência cardíaca grave. Objetivos: Estudar a evolução tardia de crianças e adultos jovens com BAVCi e estimulação crônica do ventrículo direito (VD), visando determinar: a prevalência de sinais clínicos e laboratoriais de insuficiência cardíaca e de remodelamento ventricular; a capacidade funcional; a qualidade de vida e fatores preditores de alterações clínicas, funcionais ou ecocardiográficas. Métodos: Estudo transversal realizado em coorte de portadores de BAVCi e MP implantado antes de 21 anos de idade com estimulação no VD há mais de um ano. Todos os indivíduos foram submetidos a avaliação clínica e laboratorial, da capacidade funcional, da qualidade de vida e a ecocardiograma. Mães e sujeitos da pesquisa foram investigados para doenças reumatológicas. Os dados foram armazenados no sistema REDCap (Research Electronic Data Capture) e analisados pelos programas SAS (Statistical Analysis System), SPSS (Statistical Package for the Social Sciences) e R Studio. A análise dos dados incluiu: análise univariada para pesquisa de associações entre variáveis preditoras e desfechos, coeficiente de correlação de Pearson e modelo de regressão linear multivariado. Resultados: De março/2010 a dezembro/2013, foram avaliados 63 indivíduos, 68% do sexo feminino, com idade de 1 a 40 anos, com MP por 13,4 ± 6,5 anos e estimulação do VD por 10,0 ± 5,4 anos. O modo de estimulação era atrioventricular em 55,6%, o percentual de estimulação de VD de 97,9 ± 4,2% e a duração do complexo QRS estimulado de 152,4 ± 20,1 ms. A maioria (88,9%) era assintomática e não utilizava medicamentos de ação cardiovascular. Maior tempo de MP (P= 0,013), maior tempo de estimulação do VD (P= 0,005), maior idade na inclusão no estudo (P= 0,032) ou menor fração de ejeção do ventrículo (FEVE) (P= 0,013) associaram-se com a presença de classe funcional II (NYHA) e/ou uso medicamentos. Os valores do peptídeo natriurético tipo B foram normais em todos os exames laboratoriais, mas houve alteração da proteína C reativa ultrassensível, fator de necrose tumoral alfa e interleucina-6 em 66%, 34% e 13% exames, respectivamente. A distância média percorrida no teste de caminha de seis minutos foi de 546,9 ± 76,2 metros (91,0 ± 12,5% do valor predito). Os escores médios da qualidade de vida foram 78,1 ± 17,7 para o \"Sumário Físico\" e 76,6 ± 17,1 para o \"Sumário Mental\" do questionário Short Form 36 (SF-36) e de 77,4 ± 18,5, para o \"Sumário Físico\" e de 77,7 ± 21,6 para o \"Sumário Psicossocial\", do Child Health Questionnaire - Parent Form 50 (CHQ-PF50). Diminuição da FEVE foi detectada em 39,7% e aumento do diâmetro diastólico do ventrículo esquerdo (DDVE) em 22,2% dos indivíduos. A idade mais avançada no primeiro implante de MP se correlacionou negativamente com menor FEVE (r= -0,302; P= 0,016); a duração do complexo QRS estimulado (r= 0,447; P= 0,002) e maior tempo sob estimulação do VD (r= 0,416; P= 0,007) se correlacionaram positivamente ao aumento do DDVE. Foi detectada dissincronia ventricular em 60,3% dos indivíduos. O retardo da ativação eletromecânica intraventricular esquerda foi de 86,5 ± 56,9 ms e interventricular, de 141,9 ± 88 ms. Contudo, não houve correlação com os fatores estudados. Autoanticorpos anti-Ro/SSA foram detectados em 18 (32,1%) mães, com associação entre idade no momento do implante do MP (P= 0,032) e uso de MP ventricular no momento do estudo (P= 0,022). A regressão linear multivariada confirmou a correlação entre a idade no momento do implante do MP com a FEVE (P= 0,016), da duração do complexo QRS estimulado (P= 0,004) e do tempo sob estimulação do VD (P= 0,014) com o DDVE. Conclusões: A prevalência de manifestações clínicas e laboratoriais de insuficiência cardíaca foi baixa; por outro lado, a de remodelamento ventricular esquerdo foi elevada. A capacidade funcional foi satisfatória, assim como a qualidade de vida, nos aspectos físicos e emocionais. Idade mais avançada no primeiro implante de MP, maior tempo sob estimulação cardíaca e complexo QRS estimulado mais alargado foram fatores independentes de remodelamento ventricular e/ou de manifestação de insuficiência cardíaca / Introduction: Isolated congenital atrioventricular block (iCAVB) is a rare condition with multiple clinical presentations. Permanent cardiac pacing is the most effective therapy for this population resulting in satisfactory long-term outcomes. However, approximately 10% of patients may have ventricular remodeling and severe heart failure. Objectives: To study the long-term effects of chronic right ventricular (RV) pacing in children and young adults with iCAVB in order to determine: prevalence of clinical and laboratory signs of heart failure and ventricular remodeling, functional capacity, quality of life and predictors of clinical, functional or echocardiographic abnormalities. Methods: Cross-sectional study of a cohort of iCAVB patients with <= 21 years old at initial pacemaker (PM) implantation and single or dual-chamber pacing in a unique RV site for a minimum of one year. All subjects underwent clinical and laboratory assessment, functional capacity, quality of life and echocardiogram. Mothers and research subjects were investigated for rheumatic diseases. Data were stored in REDCap (Research Electronic Data Capture) system and analyzed by SAS (Statistical Analysis System), SPSS (Statistical Package for the Social Sciences) and R Studio programs. Data analysis included: univariate analysis for associations between predictor variables and outcomes, Pearson correlation coefficient and linear regression multivariate model. Results: Between March/2010 and December/2013, we evaluated 63 subjects aged 1-40 years old, 68% female, under PM for 13.4 ± 6.5 years and under RV pacing for 10.0 ± 5.4 years. Pacing mode was atrioventricular in 55.6%, percentage of RV pacing was 97.9 ± 4.2% and paced QRS duration was 152.4 ± 20.1 ms. Overall, the majority (88.9%) were asymptomatic and did not use cardiovascular drugs. Longer time under PM (P= 0.013), or even under RV pacing (P= 0.005), higher age at study inclusion (P= 0.032) and lower left ventricular ejection fraction (LVEF) (P= 0.013) were associated with functional class II (NYHA) and / or drug use. B-natriuretic peptide values were normal in all tests. C reactive protein ultrasensitive, tumor necrosis factor alfa and interleukin-6 were increased in 66%, 34% and 13% tests, respectively. The mean walked distance in the sex minute walk test was 546.9 ± 76.2 meters (91.0 ± 12.5% of the predicted value). Mean scores of quality of life were 78.1 ± 17.7 for \"Physical Summary\" and 76.6 ± 17.1 for \"Mental Summary\" in the Short Form 36 (SF-36) and 77.4 ± 18.5 for \"Physical Summary\" and 77.7 ± 21.6 for \"Psychosocial Summary\", of Child Health Questionnaire - Parent Form 50 (CHQ-PF50). Decreased LVEF was detected in 39.7% and increased left ventricular end-diastolic diameter (LVDD) in 22.2% of subjects. Higher age at the first PM implant was negatively correlated with lower LVEF (r= -0.302; P= 0.016); paced QRS duration (r= 0.447; P= 0.002) and time under RV pacing (r= 0.416; P= 0.007) were positively correlated with LVDD. Ventricular dyssynchrony was detected in 60.3 % of individuals. Intra-left ventricular electromechanical delay was 86.5 ± 56.9 ms and interventricular was 141.9 ± 88 ms. However, ventricular dyssynchrony was not correlated with the studied variables. Autoantibodies anti-SSA/Ro were detected in 18 (32.1%) mothers. There was association between age at PM implant (P= 0.032) and use of ventricular PM at the time of the study (P= 0.022) and presence of anti-SSA/Ro. Multivariate linear regression showed significant correlation between age at PM implant with LVEF (P= 0.016); and paced QRS duration (P= 0.005) and time under RV pacing (P= 0.014) with LVDD. Conclusions: Clinical and laboratorial manifestations of heart failure presented low prevalence in this population. On the other hand, the prevalence of left ventricular remodeling was high. Functional capacity was adequate, as well as quality of life, in both physical and emotional aspects. Higher age at first PM implant, longer time under pacing and wider paced QRS duration were independent factors of ventricular remodeling and/or manifestation of heart failure
4

Avaliação da estimulação ventricular direita crônica em crianças e adultos jovens com bloqueio atrioventricular congênito isolado / Evaluation of chronic right ventricular pacing in children and young adults with isolated congenital complete atrioventricular block

Roberto Marcio de Oliveira Júnior 24 April 2014 (has links)
Introdução: O bloqueio atrioventricular congênito isolado (BAVCi) é raro e tem múltiplas apresentações clínicas. O implante de marca-passo cardíaco permanente (MP) é o tratamento de escolha, resultando em evolução clínica satisfatória para a maioria dos casos, porém, aproximadamente 10% deles apresentam remodelamento ventricular e insuficiência cardíaca grave. Objetivos: Estudar a evolução tardia de crianças e adultos jovens com BAVCi e estimulação crônica do ventrículo direito (VD), visando determinar: a prevalência de sinais clínicos e laboratoriais de insuficiência cardíaca e de remodelamento ventricular; a capacidade funcional; a qualidade de vida e fatores preditores de alterações clínicas, funcionais ou ecocardiográficas. Métodos: Estudo transversal realizado em coorte de portadores de BAVCi e MP implantado antes de 21 anos de idade com estimulação no VD há mais de um ano. Todos os indivíduos foram submetidos a avaliação clínica e laboratorial, da capacidade funcional, da qualidade de vida e a ecocardiograma. Mães e sujeitos da pesquisa foram investigados para doenças reumatológicas. Os dados foram armazenados no sistema REDCap (Research Electronic Data Capture) e analisados pelos programas SAS (Statistical Analysis System), SPSS (Statistical Package for the Social Sciences) e R Studio. A análise dos dados incluiu: análise univariada para pesquisa de associações entre variáveis preditoras e desfechos, coeficiente de correlação de Pearson e modelo de regressão linear multivariado. Resultados: De março/2010 a dezembro/2013, foram avaliados 63 indivíduos, 68% do sexo feminino, com idade de 1 a 40 anos, com MP por 13,4 ± 6,5 anos e estimulação do VD por 10,0 ± 5,4 anos. O modo de estimulação era atrioventricular em 55,6%, o percentual de estimulação de VD de 97,9 ± 4,2% e a duração do complexo QRS estimulado de 152,4 ± 20,1 ms. A maioria (88,9%) era assintomática e não utilizava medicamentos de ação cardiovascular. Maior tempo de MP (P= 0,013), maior tempo de estimulação do VD (P= 0,005), maior idade na inclusão no estudo (P= 0,032) ou menor fração de ejeção do ventrículo (FEVE) (P= 0,013) associaram-se com a presença de classe funcional II (NYHA) e/ou uso medicamentos. Os valores do peptídeo natriurético tipo B foram normais em todos os exames laboratoriais, mas houve alteração da proteína C reativa ultrassensível, fator de necrose tumoral alfa e interleucina-6 em 66%, 34% e 13% exames, respectivamente. A distância média percorrida no teste de caminha de seis minutos foi de 546,9 ± 76,2 metros (91,0 ± 12,5% do valor predito). Os escores médios da qualidade de vida foram 78,1 ± 17,7 para o \"Sumário Físico\" e 76,6 ± 17,1 para o \"Sumário Mental\" do questionário Short Form 36 (SF-36) e de 77,4 ± 18,5, para o \"Sumário Físico\" e de 77,7 ± 21,6 para o \"Sumário Psicossocial\", do Child Health Questionnaire - Parent Form 50 (CHQ-PF50). Diminuição da FEVE foi detectada em 39,7% e aumento do diâmetro diastólico do ventrículo esquerdo (DDVE) em 22,2% dos indivíduos. A idade mais avançada no primeiro implante de MP se correlacionou negativamente com menor FEVE (r= -0,302; P= 0,016); a duração do complexo QRS estimulado (r= 0,447; P= 0,002) e maior tempo sob estimulação do VD (r= 0,416; P= 0,007) se correlacionaram positivamente ao aumento do DDVE. Foi detectada dissincronia ventricular em 60,3% dos indivíduos. O retardo da ativação eletromecânica intraventricular esquerda foi de 86,5 ± 56,9 ms e interventricular, de 141,9 ± 88 ms. Contudo, não houve correlação com os fatores estudados. Autoanticorpos anti-Ro/SSA foram detectados em 18 (32,1%) mães, com associação entre idade no momento do implante do MP (P= 0,032) e uso de MP ventricular no momento do estudo (P= 0,022). A regressão linear multivariada confirmou a correlação entre a idade no momento do implante do MP com a FEVE (P= 0,016), da duração do complexo QRS estimulado (P= 0,004) e do tempo sob estimulação do VD (P= 0,014) com o DDVE. Conclusões: A prevalência de manifestações clínicas e laboratoriais de insuficiência cardíaca foi baixa; por outro lado, a de remodelamento ventricular esquerdo foi elevada. A capacidade funcional foi satisfatória, assim como a qualidade de vida, nos aspectos físicos e emocionais. Idade mais avançada no primeiro implante de MP, maior tempo sob estimulação cardíaca e complexo QRS estimulado mais alargado foram fatores independentes de remodelamento ventricular e/ou de manifestação de insuficiência cardíaca / Introduction: Isolated congenital atrioventricular block (iCAVB) is a rare condition with multiple clinical presentations. Permanent cardiac pacing is the most effective therapy for this population resulting in satisfactory long-term outcomes. However, approximately 10% of patients may have ventricular remodeling and severe heart failure. Objectives: To study the long-term effects of chronic right ventricular (RV) pacing in children and young adults with iCAVB in order to determine: prevalence of clinical and laboratory signs of heart failure and ventricular remodeling, functional capacity, quality of life and predictors of clinical, functional or echocardiographic abnormalities. Methods: Cross-sectional study of a cohort of iCAVB patients with <= 21 years old at initial pacemaker (PM) implantation and single or dual-chamber pacing in a unique RV site for a minimum of one year. All subjects underwent clinical and laboratory assessment, functional capacity, quality of life and echocardiogram. Mothers and research subjects were investigated for rheumatic diseases. Data were stored in REDCap (Research Electronic Data Capture) system and analyzed by SAS (Statistical Analysis System), SPSS (Statistical Package for the Social Sciences) and R Studio programs. Data analysis included: univariate analysis for associations between predictor variables and outcomes, Pearson correlation coefficient and linear regression multivariate model. Results: Between March/2010 and December/2013, we evaluated 63 subjects aged 1-40 years old, 68% female, under PM for 13.4 ± 6.5 years and under RV pacing for 10.0 ± 5.4 years. Pacing mode was atrioventricular in 55.6%, percentage of RV pacing was 97.9 ± 4.2% and paced QRS duration was 152.4 ± 20.1 ms. Overall, the majority (88.9%) were asymptomatic and did not use cardiovascular drugs. Longer time under PM (P= 0.013), or even under RV pacing (P= 0.005), higher age at study inclusion (P= 0.032) and lower left ventricular ejection fraction (LVEF) (P= 0.013) were associated with functional class II (NYHA) and / or drug use. B-natriuretic peptide values were normal in all tests. C reactive protein ultrasensitive, tumor necrosis factor alfa and interleukin-6 were increased in 66%, 34% and 13% tests, respectively. The mean walked distance in the sex minute walk test was 546.9 ± 76.2 meters (91.0 ± 12.5% of the predicted value). Mean scores of quality of life were 78.1 ± 17.7 for \"Physical Summary\" and 76.6 ± 17.1 for \"Mental Summary\" in the Short Form 36 (SF-36) and 77.4 ± 18.5 for \"Physical Summary\" and 77.7 ± 21.6 for \"Psychosocial Summary\", of Child Health Questionnaire - Parent Form 50 (CHQ-PF50). Decreased LVEF was detected in 39.7% and increased left ventricular end-diastolic diameter (LVDD) in 22.2% of subjects. Higher age at the first PM implant was negatively correlated with lower LVEF (r= -0.302; P= 0.016); paced QRS duration (r= 0.447; P= 0.002) and time under RV pacing (r= 0.416; P= 0.007) were positively correlated with LVDD. Ventricular dyssynchrony was detected in 60.3 % of individuals. Intra-left ventricular electromechanical delay was 86.5 ± 56.9 ms and interventricular was 141.9 ± 88 ms. However, ventricular dyssynchrony was not correlated with the studied variables. Autoantibodies anti-SSA/Ro were detected in 18 (32.1%) mothers. There was association between age at PM implant (P= 0.032) and use of ventricular PM at the time of the study (P= 0.022) and presence of anti-SSA/Ro. Multivariate linear regression showed significant correlation between age at PM implant with LVEF (P= 0.016); and paced QRS duration (P= 0.005) and time under RV pacing (P= 0.014) with LVDD. Conclusions: Clinical and laboratorial manifestations of heart failure presented low prevalence in this population. On the other hand, the prevalence of left ventricular remodeling was high. Functional capacity was adequate, as well as quality of life, in both physical and emotional aspects. Higher age at first PM implant, longer time under pacing and wider paced QRS duration were independent factors of ventricular remodeling and/or manifestation of heart failure

Page generated in 0.0616 seconds