The Modeling and Control of a Cascaded-Multilevel Converter-Based STATCOMSirisukprasert, Siriroj 23 April 2004 (has links)
This dissertation is dedicated to a comprehensive study of static synchronous compensator (STATCOM) systems utilizing cascaded-multilevel converters (CMCs). Among flexible AC transmission system (FACTS) controllers, the STATCOM has shown feasibility in terms of cost-effectiveness in a wide range of problem-solving abilities from transmission to distribution levels. Referring to the literature reviews, the CMC with separated DC capacitors is clearly the most feasible topology for use as a power converter in the STATCOM applications. The controls for the CMC-based STATCOM were, however, very complicated. The intricate control design was begun without well-defined system transfer functions. The control compensators were, therefore, randomly selected. The stability of the system was achieved by trial and error processes, which were time-consuming and ineffective. To be able to operate in a high-voltage application, a large number of DC capacitors are utilized in a CMC-based STATCOM. All DC capacitor voltages must be balanced in order to avoid over-voltages on any particular link. Not only do these uneven DC voltages introduce voltage stress on the semiconductor switches, but they also lower the quality of the synthesized output waveforms of the converter. Previous researches into DC capacitor voltage-balancing techniques were very straightforward, in that individual voltage compensators were added into the main control loop. However, the compensator design for these individual loops is very problematic because of the complexity of the voltage-loop transfer functions. Basically, the trial and error technique again provides the simplest way to achieve acceptable compensators. Moreover, the greater number of voltage levels, the more complex the control design, and the main controller must perform all of the feedback control procedures. As a result, this approach potentially reduces the reliability of the controller.
The goal of this dissertation is to achieve high-performance, reliable, flexible, cost-effective power stages and controllers for the CMC-based STATCOM. Major contributions are addressed as follows: 1) optimized design for the CMC-based STATCOM power stages and passive components, 2) accurate models of the CMC for reactive power compensations in both ABC and DQ0 coordinates, 3) an effective decoupling power control technique, 4) DC-link balancing strategies; and 5) improvements in the CMC topology.
To enhance the modularity and output voltage of the CMC, the high-switching-frequency, high-power H-bridge building block (HBBB) and the optimized design for its power stage and snubber circuits are first proposed. The high-switching-frequency feature is achieved by utilizing the Virginia Tech-patented emitter turn-off (ETO) thyristor. Three high-power HBBB prototypes were implemented, and their performance was experimentally verified.
To simplify the control system design, well-defined models of the CMC in both ABC and DQ0 coordinates are proposed. The proposed models are for the CMC with any number of voltage levels. The key system transfer functions are achieved and used in the control design processes. To achieve independent power control capability, the control technique, called the decoupling power control, is proposed. By applying this control technique, real and reactive power components can be controlled separately.
In order to balance the DC capacitor voltages, a new, effective pulse width modulation (PWM) technique, which is suitable for any number of H-bridge converters, is proposed. The proposed cascaded PWM algorithm can be practically realized into the field programmable gate arrays (FPGA), and its complexity is not affected by the number of voltage levels. In addition, the complexity of the main controller, which is essentially based on the digital signal processor (DSP), is no longer a function of the number of the output voltage levels. The basic structure of the cascaded PWM is modular, which, in general, enhances the modularity of the CMC power stages.
With the combination of the decoupling power control and the cascaded PWM, a CMC with any number of voltage levels can be simply modeled as a three-level cascaded converter, which is the simplest topology to deal with. This significantly simplifies and optimizes the control design process. To verify the accuracy of the proposed models and the performance of the control system for the CMC-based STATCOM, a low-power, seven-level cascaded-based STATCOM hardware prototype is implemented. The key control procedures are performed by a main controller, which consists of a DSP and an FPGA. The simulation and experimental results indicate the superior performance of the proposed control system, as well as the precision of the proposed models. / Ph. D.
|
2 |
Modeling and Simulation of a Cascaded Three-Level Converter-Based SSSCHawley, Joshua Christiaan 06 September 2004 (has links)
This thesis is dedicated to a comprehensive study of static series synchronous compensator (SSSC) systems utilizing cascaded-multilevel converters (CMCs). Among flexible AC transmission system (FACTS) controllers, the SSSC has shown feasibility in terms of cost-effectiveness in a wide range of problem-solving abilities from transmission to distribution levels. Referring to the literature reviews, the CMC with separated DC capacitors is clearly the most feasible topology for use as a power converter in the SSSC applications. The control for the CMC-Based SSSC is complicated. The design of the complicated control strategy was begun with well-defined system transfer functions. The stability of the system was achieved by trial and error processes, which were time-consuming and ineffective.
The goal of this thesis is to achieve a reliable controller design for the CMC-based SSSC. Major contributions are addressed as follows: 1) accurate models of the CMC for reactive power compensations in both ABC and DQ0 coordinates, and 2) an effective decoupling power control technique.
To simplify the control system design, well-defined models of the CMC-Based SSSC in both ABC and DQ0 coordinates are proposed. The proposed models are for the CMC-Based SSSC focus on only three voltage levels but can be expanded for any number of voltage levels. The key system transfer functions are derived and used in the controller design process. To achieve independent power control capability, the control technique, called the decoupling power control used in the design for the CMC-Based STATCOM is applied. This control technique allows both the real and reactive power components to be independently controlled.
With the combination of the decoupling power control and the cascaded PWM, a CMC with any number of voltage levels can be simply modeled as a three-level cascaded converter, which is the simplest topology to deal with. This thesis focuses on the detailed design process needed for a CMC-Based SSSC. / Master of Science
|
3 |
Estratégias de modulação para conversores multiníveis em cascata sob faltas / New modulation strategies for cascaded multilevel convertersCarnielutti, Fernanda de Morais 20 January 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Multilevel converters are being increasingly employed nowadays, specially in mediumand
high-voltage industrial applications. Even though these converters are able to
synthesize output line-to-line voltages with a high number of levels, close to a sinusoidal
waveform, their modulation is more complex than the one for two- and three-level
converters. In this context, this dissertation proposes new modulation strategies for
multilevel converters, specifically symmetrical and asymmetrical cascaded multilevel ones,
composed of many full-bridges, or power cells, per phase. If the converter has one
or more faulty cells, they can be bypassed and the converter can continue to feed the
load, increasing the process reliability. However, the converter phase voltages must be
modified so as to keep the output line-to-line voltages balanced. With the objective
of proposing modulation strategies that allow the cascaded multilevel converters to
satisfactorily operate under these conditions, an extensive bibliographical review of the
existing modulation techniques has been carried out. The carrier-based modulation
approaches were studied first. It could be noticed that all these strategies belong to a
larger set of solutions for the obtention of the converter modulating phase voltages. This
set is derived in this work, resulting in a generalized geometrical modulation strategy for
symmetrical and asymmetrical cascaded multilevel converters with any number of levels
and operating under normal or faulty conditions. As the faulty cells are restrictions for
converter operation, for each fault condition the region that contains all the possible
converter common-mode voltages, that compensate for the loss of cells, is derived. The
choice of a common-mode pertaining to this set allows the entire converter synthesis
capability to be explored. The modulating voltages are the sum of the reference and the
common-mode voltages, maximizing the amplitudes of the output line-to-line voltages.
For asymmetrical cascaded multilevel converters, the voltages synthesized by the highervoltage
cells are restrictions for the operation of the lower-voltage ones. Concerning
the Space Vector (SV) modulation, it was derived only for the asymmetrical cascaded
multilevel converter. The higher-voltage and lower-voltage cells switch, respectively, with
low frequency by the choice of the nearest vector to the reference, and with high frequency,
by the choice of the three nearest vectors to the reference, in one switching period. The
voltage synthesized by the higher-voltage cells is subtracted from the reference, resulting
in the new reference for the lower-voltage cells, and so successively, until the cells with the
lowest voltages. A specific switching sequence is defined off-line for each sector of the SV
diagram. The algorithm is carried out in a modified αβo coordinate system, resulting in
switching vector with only integer entries. The choice of the switching vectors considers all
the possible redundancies in abc coordinates. At last, simulation and experimental results
Abstract
that prove the good performance of the proposed modulation strategies are presented. / Conversores multiníveis são cada vez mais empregados, especialmente em aplicações
industriais de média e alta tens~ao. Apesar de serem capazes de sintetizar tensões de linha de saída com um grande número de níveis, se aproximando de uma forma de onda
senoidal, sua modulação é mais complexa, quando comparada com conversores de dois ou
três níveis. Neste contexto, esta dissertação propõe novas estratégias de modulação para conversores multiníveis, especificamente multiníveis em cascata simétricos e assimétricos,
compostos por diversos full-bridges, ou células de potência, por fase. Caso uma ou mais células sofram faltas, estas podem ser retiradas de operação, e o conversor pode continuar
a alimentar a carga, aumentando a confiabilidade do processo. Contudo, as tensõe de fase do conversor devem ser modificadas, a fim de manter as tensões de linha de saída
equilibradas. Com o objetivo de propor estratégias de modulação que permitam aos conversores multiníveis em cascata operar satisfatoriamente nestas condições, foi realizada
uma extensa pesquisa bibliográfica a respeito dos métodos de modulação já existentes
na literatura. Primeiramente, foram estudadas estratégias de modulação baseadas em portadora. Pode-se perceber que estas pertencem a um conjunto maior de possíveis
soluções para a obtenção das tensões modulantes para as fases do conversor. Este conjunto
é derivado neste trabalho, resultando em uma estratégia generalizada de modulação com abordagem geométrica para conversores multiníveis em cascata simétricos e assimétricos
com qualquer número de níveis, em operação normal ou sob faltas. Como as células com falta são restrições para o funcionamento do conversor, para cada condição de falta é
definida a região que contém todas as possíveis tensões de modo comum que podem ser sintetizadas pelo conversor a fim de compensar a perda de células. A escolha de uma tensão
de modo comum pertencente a este conjunto permite explorar toda a capacidade de síntese de tensão do conversor. As tensões modulantes são obtidas como a soma das tensões
de referência de fase e de modo comum, maximizando as amplitudes das componentes fundamentais das tensões de linha de saída. Para os conversores multiníveis em cascata
assimétricos, as tensões sintetizadas pelas células de maior tensão são restrições para a operação das demais. Quanto à modulação Space Vector (SV), optou-se por desenvolvê-la
apenas para conversores multiníveis em cascata assimétricos. As células de alta tensão comutam em baixa frequência pela escolha do vetor mais próximo da referência, e as células de baixa tensão comutam em alta frequência pela escolha dos três vetores mais
próximos da referência, em um período de comutação. A tensão sintetizada pelas células
de alta tensão é subtraída da referência, resultando na nova referência para as próximas
células, e assim sucessivamente até as células de menor tensão. Para cada setor do Resumo diagrama SV é definida off-line uma sequência de comutação específica. O algoritmo implementado realiza todos os cálculos em um sistema de coordenadas αβo modificado,
resultando em vetores de comutação apenas com elementos inteiros. A escolha dos vetores
de comutação a serem implementados considera todas as suas possíveis redundâncias em coordenadas abc. Por fim, são apresentados resultados de simulação e experimentais que
comprovam o ótimo desempenho das estratégias de modulação propostas neste trabalho.
|
4 |
Modulação space vector para conversores multiníveis com células assimétricas em cascata sob condições de faltas / Space vector modulation for cascaded multilevel converters with asymmetric cells under fault conditionsCarnielutti, Fernanda de Morais 09 October 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This Thesis proposes a Space Vector Modulation for cascaded miltilevel converters with
asymmetric cells under normal conditions and with faults in the power cells, avoiding
converter saturation as much as possible. The switching state vectors and the voltage
references are represented in the output line-to-line voltages coordinate system. Under
this representation, the switching state vectors have only integer entries, easing the implementation
of the proposed algorithm. The modulation is developed in a way such as
to guarantee that the higher voltage cells switch at low frequency by the choice of only
one vector per switching period, minimizing the switching losses. For the lower voltage
cells (1pu), that switch with PWM, three algorithms were developed for defining the switching
sequences: (i) offline, (ii) online and (iii) hybrid, where a carrier-based geometrical
modulation and the SV are mixed in a simple and unified approach. The algorithm is
described in a generic way, for converters with any number of levels, and then, simulation
and experimental results are shown for, respectively, cascaded miltilevel converters with
asymmetric cells with DC bus voltages ratio of 1:2:4pu and 1:2pu. The algorithm does
not use conventional separation lines to find where the multiple references for the power
cells are located inside the SV diagram. It also avoids converter saturation and, when it is
unavoidable, detects its occurrence and changes the operation mode to overmodulation.
This one is treated as a modification of the orignal algorithm, allowing the converter to
operate with a wider range of modulation indexes and fault conditions. It is shown that
two overmodulation modes can occur: in the first, there is still an area inside the SV diagram
where overmodulation is avoided, and, in the second, the converter overmodulates
during almost all the time. Modulation strategies are proposed for both cases, including
the insertion of a bandpass filter in the second case, so as to minimize the distortions and
unbalances that arise on the converter output line-to-line voltages during this operation
mode. For the overmodulation, simulation and experimental results are also shown for
cascaded miltilevel converters with asymmetric cells with DC bus voltages ratio of 1:2:4pu
and 1:2pu. Finally, the final conclusions are drawn and future works are proposed. / Esta Tese propõe uma estratégia de modulação Space Vector (SV) para conversores
multiníveis com células assimétricas em cascata durante operação normal e com faltas nas
células de potência, garantindo a não ocorrência de saturação do conversor sempre que esta
não for desejada, especialmente durante faltas. Os vetores de comutação e as referências de
tensão são representados no sistema de coordenadas das tensões de linha de saída. Desta
forma, os vetores de comutação apresentam apenas coordenadas inteiras, facilitando a
implementação do algoritmo proposto. A modulação é desenvolvida de forma a garantir
que as células de maior tensão comutem em baixa frequência, pela escolha de apenas
um vetor por período de comutação, minimizando as perdas de comutação do conversor.
Para as células de menor tensão (1pu), que comutam com PWM, foram desenvolvidos três
algoritmos para definição das sequências de comutação: definição (i) offline, (ii) online e
(iii) híbrida, onde as modulações geométrica com portadora e SV são mescladas em uma
abordagem única e simplificada. O algoritmo SV é descrito de maneira genérica, para
conversores com qualquer número de níveis, e, na sequência, são apresentados resultados
de simulação e experimentais para, respectivamente, conversores multiníveis com células
assimétricas em cascata com razão das tensões dos barramentos CC de 1:2:4pu e 1:2pu.
Este algoritmo não faz uso de retas de separação convencionais para encontrar os domínios
onde as múltiplas referências para as células de potência se encontram dentro do diagrama
SV. Também evita ao máximo a saturação do conversor, e, quando esta é inevitável,
detecta sua ocorrência e muda o modo de operação para sobremodulação. Esta é tratada
por meio de modificações no algoritmo original, permitindo a operação do conversor com
um maior número de índices de modulação e condições de falta. É mostrado que existem
dois casos de sobremodulação durante faltas nas células de potência: no primeiro, ainda há
uma área no interior do diagrama SV onde a sobremodulação é evitada, e, no segundo, o
conversor sobremodula durante praticamente todo o tempo. São propostas estratégias de
modulação para ambos os casos, incluindo a inserção de um filtro passa-faixa no segundo,
para minimizar as distorções e os desequilíbrios que surgem nas tensões de linha de saída
do conversor, quando este se encontra neste modo de operação. Para a sobremodulação,
também são apresentados resultados de simulação e experimentais para os conversores
multiníveis com células assimétricas em cascata com razão das tensões dos barramentos
CC de 1:2:4pu e 1:2pu. Por fim, as conclusões finais são apresentadas e são propostos
trabalhos futuros.
|
Page generated in 0.073 seconds