• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Study on complexity reduction of digital predistortion for power amplifier linearization / Etude sur la réduction de complexité de la prédistorsion numérique pour la linéarisation de l'amplificateur de puissance

Wang, Siqi 23 January 2018 (has links)
Ce travail concerne la linéarisation des amplificateurs de haute puissance en utilisant la pré-distorsion numérique. L’amplificateur de haute puissance est un composant non-linéaire. La pré-distorsion numérique adaptative en bande de base est un technique efficace pour linéariser ses non-linéarités et ses effets de mémoire. Les modèles de la pré-distorsion numérique de basse complexité sont étudiés dans cette thèse. Un algorithme est proposé pour déterminer une structure optimale de modèle uni-étage ou multi-étage en prenant compte du compromis entre la précision de modélisation et la complexité. La structure cascadée, qui est avantageuse en complexité comparé avec celle d'uni-étage, est étudiée avec des méthodes d'identifications différentes. En termes d'implémentations expérimentales, l'étude d'impact des choix de gain différents est approfondie dans cette thèse. Toutes les études ont été évaluées par un amplificateur de puissance Doherty / This dissertation contributes to the linearization techniques of high power amplifier using digital predistortion method. High power amplifier is one of the most nonlinear components in radio transmitters. Unfortunately, for most current types of power amplifiers, a good efficiency is obtained at the price of a poor linearity especially with modern communication waveforms. Baseband adaptive digital predistortion is a powerful technique to linearize the power amplifiers and allows to push the power amplifier operation point towards its high efficiency region. Linearization of power amplifiers using digital predistortion with low complexities is the focus of this dissertation. An algorithm is proposed to determine an optimal model structure of single-stage or multi-stage predistorter according to a trade-off between modeling accuracy and model complexity. Multi-stage cascaded digital predistortions are studied with different identification methods, which have advantages on complexity of model identification compared with single-stage structure. The linearization performances are validated by experimental implementations on test bench. In terms of experimental implementations, this dissertation studies the impact of different gain choices on linearized power amplifier. All studies are evaluated with a Doherty power amplifier
2

Beyond Orthographic Segmentation: Neurophysiological Evidence That Pseudo-Derived Word Stems Are Processed Semantically

Herbert, Theresa 13 March 2009 (has links)
Morphological segmentation while reading is essential for new vocabulary learning. The study's aim was to investigate semantic-level morphological segmentation using event-related brain potentials (ERPs) in typical young adult readers. Past research has suggested that, because semantically opaque words prime their stems (e.g., corner/corn) similarly to transparent words (e.g., farmer/farm), readers recognize complex words from their constituent morphemes without regard to semantic information. However, this priming effect may be due to orthographic and phonological overlap between prime and target words. The research presented here addressed this possibility by creating five conditions in which orthographic, phonological, and semantic relationships between prime and target words were manipulated: Condition 1,wherein prime and target shared no relationship (e.g., inn/brother), served as Control. In Condition 2, prime and target were the same (e.g., brother/brother). In Condition 3, prime was the stem of target (e.g., broth/brother). Condition 4, our critical experimental condition, used primes semantically related to the stem of the target word (e.g., soup/brother). Finally, in Condition 5, prime was semantically related to the whole target word (e.g., sibling/brother). Semantically priming the stem (Condition 4) did not modulate the amplitude of the standard N400 ERP component (as did Conditions 2, 3, and 5), but did affect an early N400-like ERP component peaking in amplitude at ~262 ms after target. Other ERPs were observed that responded uniquely to shared orthography (Conditions 2, 3). Results set the stage for investigating morphological processing in adult reading impairments to evaluate whether, and to what extent, these readers semantically process morphological stems during text comprehension.
3

Contribution des technologies CPL et sans fil à la supervision des réseaux de distribution d'électricité / Contribution of PLC and wireless technologies to supervision of electric distribution networks

Lefort, Romain 03 February 2015 (has links)
Le déploiement d'une infrastructure de supervision permet une gestion plus intelligente des réseaux de distribution d'électricité comparé à un renforcement traditionnel pour répondre aux nouveaux enjeux de la maitrise de l'énergie (Consommations, EnR, VE, ...). Pour acheminer les données, les Courants Porteurs en Ligne (CPL) possèdent un atout majeur. En effet, cette technologie permet de superposer un signal de plus haute fréquence au signal électrique 50/60 Hz. Toutefois, le support de transmission est difficile et non maîtrisable. Ces travaux de recherche ont pour objectif d'apporter une contribution à cette problématique par l'élaboration d'une plateforme de simulation des réseaux pour des fréquences allant jusqu'à 1 MHz dans un but de transmission de données. Des éléments clés des réseaux sont traités de façon séparés puis assemblés pour estimer les performances des CPL « Outdoor » actuels. La variation du comportement des réseaux en fonction du temps et de la fréquence, en particulier des perturbations en tête d'installation clients sur 24h est étudiée. Les transformateurs entre les réseaux HTA et BT sont modélisés sous la forme d'un « modèle à constantes localisées » et d'un « modèle boite noire ». Les deux modèles sont appliqués sur un transformateur H61 100 kVA. Par la suite, une modélisation des câbles de distribution est proposée sous forme d'un « modèle cascadé ». Celle-ci est appliquée sur un câble souterrain BT. Chaque modèle est obtenu à l'aide de mesures d'impédances, et validé par des mesures de transmissions. Pour compléter, une étude préliminaire sur les communications radio mobile est réalisée pour la supervision des réseaux de distribution. / Establishing a supervisory infrastructure allows a better smart management than an expensive strengthening of distribution network to respond to new constraints at the energies control (Consumption, REN, EV ...). To transmit data, Power Line Communication (PLC) technologies present an advantage in this context. In fact, it enables a superposition of High Frequency (HF) signals on electrical signal 50/60 Hz. However, electric networks have not been developed to this application because of difficult propagation conditions. This research work makes a contribution to develop a simulation platform in objective to transmit data to 1 MHz. In first time, each network element is studied singly and in second time, together, to estimate "Outdoor PLC" transmission performance. The first element studied is the networks variation in function of frequency and time. Several 24h disturbance measurements on LV customers are presented. The second element is the transformers which established connection between Medium Voltage (MV) and Low Voltage (LV). The proposed modeling method is based on a "lumped model" and a "black box model". These models are applied to a 100 kVA H61 transformer most commonly used by French distribution system operator in rural and suburban networks. The third element is the power line used in MV and LV networks. The proposed modeling method is based on a "cascaded model" from the theory of transmission line. This model is applied to one power line used in LV underground network. Each model is obtained from various impedance measurements. To complete, an introductory study on mobile radio communication is performed to remote network distribution.

Page generated in 0.0626 seconds