• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 13
  • 13
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Vers l’étalonnage interne de caméra à haute précision / Towards high precision internal camera calibration

Rudakova, Victoria 21 January 2014 (has links)
Cette thèse se concentre sur le sujet de la calibration de la camera interne et, en particulier, sur les aspects de haute précision. On suit et examine deux fils principaux: la correction d'une aberration chromatique de lentille et l'estimation des paramètres intrinsèques de la caméra. Pour la problème de l'aberration chromatique, on suit un chemin de post-traitement numérique de l'image, afin de se débarrasser des artefacts de couleur provoqués par le phénomène de dispersion du système d'objectif de la caméra, ce qui produit une désalignement perceptible des canaux couleur. Dans ce contexte, l'idée principale est de trouver un modèle de correction plus général pour réaligner les canaux de couleur que ce qui est couramment utilisé - différentes variantes du polynôme radial. Celui-ci ne peut pas être suffisamment général pour assurer la correction précise pour tous les types de caméras. En combinaison avec une détection précise des points clés, la correction la plus précise de l'aberration chromatique est obtenue en utilisant un modèle polynomial qui est capable de capter la nature physique du décalage des canaux couleur. Notre détection de points clés donne une précision allant jusqu'à 0,05 pixels, et nos expériences montrent sa grande résistance au bruit et au flou. Notre méthode de correction de l’aberration, par opposition aux logiciels existants, montre une géométrique résiduelle inférieure à 0,1 pixels, ce qui est la limite de la perception de la vision humaine. En ce qui concerne l'estimation des paramètres intrinsèques de la caméra, la question est de savoir comment éviter la compensation d'erreur résiduelle qui est inhérent aux méthodes globales d'étalonnage, dont le principe fondamental consiste à estimer tous les paramètres de la caméra ensemble - l'ajustement de faisceaux. Détacher les estimations de la distorsion de la caméra et des paramètres intrinsèques devient possible lorsque la distorsion est compensée séparément. Cela peut se faire au moyen de la harpe d'étalonnage, récemment développée, qui calcule le champ de distorsion en utilisant la mesure de la rectitude de cordes tendues dans différentes orientations. Une autre difficulté, étant donnée une image déjà corrigée de la distorsion, est de savoir comment éliminer un biais perspectif. Ce biais dû à la perspective est présent quand on utilise les centres de cibles circulaires comme points clés, et il s'amplifie avec l'augmentation de l'angle de vue. Afin d'éviter la modélisation de chaque cercle par une fonction conique, nous intégrons plutôt fonction de transformation affine conique dans la procédure de minimisation pour l'estimation de l'homographie. Nos expériences montrent que l'élimination séparée de la distorsion et la correction du biais perspectif sont efficaces et plus stables pour l'estimation des paramètres intrinsèques de la caméra que la méthode d'étalonnage globale / This dissertation focuses on internal camera calibration and, especially, on its high-precision aspects. Two main threads are followed and examined: lens chromatic aberration correction and estimation of camera intrinsic parameters. For the chromatic aberration problem, we follow a path of digital post-processing of the image in order to get rid from the color artefacts caused by dispersion phenomena of the camera lens system, leading to a noticeable color channels misalignment. In this context, the main idea is to search for a more general correction model to realign color channels than what is commonly used - different variations of radial polynomial. The latter may not be general enough to ensure stable correction for all types of cameras. Combined with an accurate detection of pattern keypoints, the most precise chromatic aberration correction is achieved by using a polynomial model, which is able to capture physical nature of color channels misalignment. Our keypoint detection yields an accuracy up to 0.05 pixels, and our experiments show its high resistance to noise and blur. Our aberration correction method, as opposed to existing software, demonstrates a final geometrical residual of less than 0.1 pixels, which is at the limit of perception by human vision. When referring to camera intrinsics calculation, the question is how to avoid residual error compensation which is inherent for global calibration methods, the main principle of which is to estimate all camera parameters simultaneously - the bundle adjustment. Detachment of the lens distortion from camera intrinsics becomes possible when the former is compensated separately, in advance. This can be done by means of the recently developed calibration harp, which captures distortion field by using the straightness measure of tightened strings in different orientations. Another difficulty, given a distortion-compensated calibration image, is how to eliminate a perspective bias. The perspective bias occurs when using centers of circular targets as keypoints, and it gets more amplified with increase of view angle. In order to avoid modelling each circle by a conic function, we rather incorporate conic affine transformation function into the minimization procedure for homography estimation. Our experiments show that separate elimination of distortion and perspective bias is effective and more stable for camera's intrinsics estimation than global calibration method
12

Conception, réalisation et évaluation d'un implant diffractif bifocal intracornéen pour la correction de la presbytie / Design, elaboration and implementation of a diffractive bifocal intracorneal implant to correct presbyopia

Castignoles, Fannie 25 November 2011 (has links)
Actuellement, la presbytie peut être corrigée chirurgicalement à l’aide d’implants intraoculaires réfractifs ou diffractifs multifocaux (chirurgie endoculaire invasive et irréversible) ou en intracornéen avec une correction multifocale réfractive (correction laser irréversible, ou insertion d’un implant dans le stroma). L’objectif de ce travail est de développer un nouvel implant permettant de corriger la presbytie, qui allie l’innocuité et la réversibilité d’une correction intracornéenne, à l’efficacité du diffractif. Le design des profils optiques bifocaux a été permis grâce au développement d’outils de simulation optique. Les efficacités de diffraction sont calculées à partir de la propagation du champ électrique par spectre angulaire. La qualité optique est déterminée d’après les simulations de Fonction de Transfert de Modulation obtenues sous Zemax. Des simulations de rendu d’images permettent de visualiser les effets de différents profils envisagés. Les paramètres critiques du design optique sont déterminés. Le choix du matériau dépend des contraintes de biocompatibilité de l’implant et des techniques de fabrication. La solution retenue est un hydrogel à forte teneur en eau, couplé à une nouvelle architecture de l’implant. L’hydrogel est obtenu par polymérisation radicalaire de macromonomères difonctionnels de poly(éthylène glycol) de masses molaires de l’ordre de 8000 g.mol‐1 qui conduisent à des propriétés mécaniques et une perméabilité aux nutriments compatibles avec l’application. La réalisation, la stérilisation et la caractérisation optique de prototypes ont abouti à la preuve du concept d’un implant bifocal diffractif intracornéen / Presbyopia can be corrected with surgery by means of refractive or diffractive multifocal intraocular lenses (which imply an irreversible and invasive endocular surgery) or by intracorneal multifocal refractive correction (irreversible laser correction, or insertion of an intrastromal implant). This work aims at developing a new implant to correct presbyopia, which takes advantage of both the harmlessness and the reversibility of an intracorneal correction, and the efficiency of diffractive optics. The design of the bifocal optical profiles was based on the development of optical simulation tools. The diffractive efficiencies are calculated from the distribution of the electric field with the method of angular spectrum. The optical quality is determined according to the simulations of Modulation Transfer Function obtained with Zemax. Images simulations show the effects of the different profiles studied. The critical parameters of the optical design are also determined. The choice of the material depends on several constraints such as biocompatibility and techniques of manufacturing. The adopted solution relies on the used of an hydrogel with high water content and the design of a new implant architecture. The hydrogel is obtained by radical polymerization of difunctional macromonomers of poly(ethylene glycol) with molar masses around 8000 g.mol‐1, allowing mechanical properties and permeability to nutriments compatible with the application. The realization, the sterilization and the characterization of prototypes showed the proof of the concept of a diffractive bifocal intracorneal implant
13

Aberration Corrector for an Exclusively Low-Voltage Electron Microscopy / Aberration Corrector for an Exclusively Low-Voltage Electron Microscopy

Bačovský, Jaromír January 2021 (has links)
Současný vývoj v oblasti nízkovoltové elektronové mikrokospie vede ke zlepšování prostorového rozlišení cestou korekce elektronově-optických vad. V posledních letech se implementace korektorů u konvenčních elektronových mikroskopů (50-200 kV) stává standardem. Nicméně zabudování korektoru do malého stolního prozařovacího mikroskopu pracujícího s nízkým urychlovacím napětím je stále výzva. Velmi vhodným řešením korekce otvorové vady u takovýchto přístrojů se zdá být koncept hexapólového korektoru založeného na bázi permantních magnetů umožňující zachovat minimální rozměry stolního transmisního mikroskopu. Přednosti a potenciál Roseho hexapólového korektoru vzhledem k použití v nízkovoltových systémech jsou předmětem kritické analýzy obsažené v této práci, včetně zásadního příspěvku tohoto korektoru k celkové chromatické vadě přístroje. Chromatická vada zůstává, navzdory veškeré snaze o její minimalizaci, zcela zásadním aspektem při návrhu korektoru. Koncept představený v rámci této dizertační práce je určen především pro skenovací prozařovací transmisní mód z důvodu omezení nárůstu chromatické vady způsobeného průchodem elektronového svazku preparátem. V práci lze také nalézt podrobný popis navržených kompenzačních systémů korektoru určených k precisnímu seřízení optické soustavy.

Page generated in 0.1343 seconds