• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 322
  • 46
  • 46
  • 46
  • 45
  • 35
  • 7
  • 7
  • 7
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 327
  • 327
  • 143
  • 131
  • 109
  • 79
  • 58
  • 57
  • 53
  • 40
  • 40
  • 34
  • 30
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Influência do tratamento de superfície e do tipo de cimento na retenção de coroas YTZP /

Rippe, Marília Pivetta. January 2013 (has links)
Orientador: Marco Antonio Bottino / Co-orientador: Luiz Felipe Valandro / Banca: Paulo Francisco César / Banca: Estevam Augusto Bonfante / Banca: Renata Marques de Melo Marinho / Banca: Alexandre Luiz Souto Borges / Resumo: Comparar a retenção de coroas de zircônia YTZP em função do protocolo de cimentação. Foram preparados para coroa total 108 molares extraídos (n = 12). Pinos de fibra de vidro foram cimentados e núcleos de resina composta construídos. Infraestruturas de zircônia YTZP foram fresadas e 72 espécimes foram alocados em 6 grupos conforme os fatores: cimento - Multilink (Mult) e Relyx ARC (Rel); e tratamento de superfície da zircônia - álcool (controle) (C), silicatização (S) e vitrificação (V). Os outros 36 espécimes foram divididos em 3 grupos cimentados com Relyx Luting (Ion), Relyx U100 (Self) e fosfato de zinco (Zinc) sem tratamento da zircônia. Todos os espécimes foram termociclados (5 - 55 ºC, 6000 ciclos) e os dados do teste de tração foram analisados pelo teste de Kruskal Wallis e Dunn. Os valores da mediana e distância interquartil foram os seguintes: MultC: 20,0 (± 5,5); MultS: 28,5 (± 22,0); MultV: 32,5 (± 28,5); RelC: 21,5 (± 8,5); RelS: 22,0 (± 10,0); RelV: 24,0 (± 7,3); Ion: 5,1 (± 6,4); Self: 3,5 (± 5,2); Zinc: 7,7 (± 14,2). O tipo de cimento resinoso (a base de Bis-GMA e HEMA) não afetaram os valores de retenção das coroas. O tratamento de superfície da cerâmica vitrificação somente foi capaz de melhorar os valores de retenção para o cimento a base de HEMA. Para superfícies cerâmicas não tratadas, os cimentos resinosos mostraram significantemente maiores valores de retenção do que aqueles obtidos para os cimentos auto-adesivo, de inonômero de vidro e de fosfato de zinco / Abstract: To compare the retention of YTZP zirconia crowns cemented to different cementation protocols. 108 extracted molars were prepared for full crown (n = 12); and the core was reconstructed with glass fiber post and composite resin core. YTZP zirconia copings were milled and 72 specimens were divided into 6 groups according to the factors: cements- Multilink (Mult) and Relyx ARC (Rel); and zirconia surface treatments- alcohol (control) (C), silica coating (S) and vitrification (V). The remaining 36 specimens were divided into 3 groups cemented with Relyx Luting (Ion), Relyx U100 (Self) and Zinc phosphate (Zinc) on untreated zirconia. The specimens were thermally cycled (5 - 55 °C, 6000 cycles) and data from the tensile test were analyzed by Kruskal Wallis and Dunn test. The median and interquartil range were: MultC: 20.0 (± 5.5); MultS: 28.5 (± 22.0); MultV: 32.5 (± 28.5); RelC: 21.5 (± 8.5); RelS: 22.0 (± 10.0); RelV: 24.0 (± 7.3); Ion: 5.1 (± 6.4); Self: 3.5 (± 5.2); Zinc: 7.7 (± 14.2). The type of resin cement (BIS-GMA- or HEMA- based) did not affect the crown retention values. The treatment involving vitrification of the cementation surface was only capable to improve the retention force for the HEMA based-cement. For untreated intaglio surfaces of YTZP crowns, resin cements showed significantly higher retention than those obtained for self-adhesive, glass ionomer and zinc phosphate cements / Doutor
72

Avaliação da biocompatibilidade e do processo de reparo dos cimentos endodônticos : MTA Fillapex, Endo-CPM-Sealer e Sealapex /

Watanabe, Simone. January 2012 (has links)
Orientador: João Eduardo Gomes Filho / Banca: Eloi Dezan Júnior / Banca: Luciano Tavares Ângelo Cintra / Banca: Mário Tanomaru Filho / Banca: Marco Antônio Hungaro Duarte / Resumo: O objetivo deste estudo foi avaliar a resposta tecidual frente ao implante de tubos de polietileno preenchidos pelos cimentos Sealapex®, Endo-CPM-Sealer® e MTA Fillapex® em tecido subcutâneo de ratos, bem como avaliar o processo de reparo de dentes de cães com lesão periapical, obtida experimentalmente, obturados com os mesmos cimentos. Para o teste de biocompatibilidade foram utilizados 30 ratos, os quais receberam individualmente três implantes de tubos de polietileno contendo os cimentos a serem testados e mais um tubo vazio como controle. Os períodos de avaliação foram de 7, 15, 30, 60 e 90 dias. Os espécimes foram processados laboratorialmente e analisados nas colorações de Hematoxilina e Eosina, Von Kossa e sem coloração para análise sob luz polarizada. Foram atribuídos escores e os dados obtidos foram analisados pelo teste Kruskal Wallis. Todos os materiais causaram reações moderadas no tempo experimental de 7 dias. A resposta foi moderada e similar para o grupo controle no 15° dia com Sealapex® e Endo-CPM-Sealer®. O grupo MTA Fillapex® apresentou reações leves a partir do 15° dia. Mineralizações e granulações brirrefringentes à luz polarizada foram observadas com todos os materiais. Foi possível concluir que todos os materiais testados apresentaram resultados similares, sendo considerados biocompatíveis e estimulantes de mineralização. Para a avaliação do processo de reparo de dentes de cães com lesão periapical, obtida experimentalmente, foram empregados 62 canais radiculares de 2 cães machos da raça Beagle. Os animais foram anestesiados, as polpas foram extirpadas e os canais ficaram expostos ao meio oral para o desenvolvimento de lesões periapicais. Após 6 meses os dentes foram tratados endodonticamente e foram divididos em 5 grupos experimentais... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the tissue response to implanted polyethylene tubes filled with Sealapex®, Endo-CPM-Sealer® and MTA Fillapex® in rat subcutaneous tissue, and to evaluate the healing process of dogs' teeth with experimental periapical lesions filled with the same sealers. For the biocompatibility test, it were used thirty rats, which received three individual implants of polyethylene tubes containing the sealers to be tested and an empty tube as control. Evaluations periods were on 7, 15, 30, 60 and 90 days. The specimens were laboratory processed and analyzed in Hematoxylin and Eosin, Von Kossa and without staining for polarized light. Scores were assigned and data were analyzed by Kruskal Wallis test. Both materials caused mild to moderate reactions on 7 days. The response was moderate and similar to the control at the 15th day with Sealapex® and Endo-CPM-Sealer®. MTA Fillapex® evoked mild reactions from the 15th day on. Mineralization and granulations birefringent to the polarized light were observed with all materials. It was possible to conclude that all materials tested showed similar results and they are considered biocompatible and stimulating mineralization. For the evaluation of the healing process of dogs' teeth with periapical lesions, sixty-two roots canals of two male beagle dogs were used. The animals were anesthetized, pulpectomy were performed and the canals remained open and exposed to the oral environment to induce a periapical lesion. After 6 months the teeth were endodontically treated and divided into 5 experimental groups, according to the filling material: Group I Sealapex®; Group II - Endo-CPM-Sealer®; Group III - MTA Fillapex®; Group IV - positive control; Group V - negative control. After 180 days, the animals were killed, the specimens were removed... (Complete abstract click electronic access below) / Doutor
73

Resistência de união de cimentos resinosos em superfície de cerâmica de Y-TZP após aplicação de filme vitrocerâmico /

Antunes, Débora Pinto. January 2014 (has links)
Orientador: Clovis Pagani / Co-orientador: Gildo Coelho Santos Júnior / Banca: Eduardo Bresciani / Banca: Taciana Marco Ferraz Caneppele / Banca: Luzia da Glória Corrêa Coelho / Banca: Rafael Barroso Pazinatto / Resumo: Comparou-se a resistência de união (RU) dos cimentos resinosos Panavia F (P) (Kuraray) e RelyX U200 (R) (3M ESPE) à cerâmica zircônia através de três diferentes métodos de tratamento da superfície: 1- silicatização triboquímica (ST) (Rocatec Soft - 3M ESPE); 2- glaze (G) (Akyzent glaze spray- VITA); 3- aplicação de vidro bioativo (VBA). Blocos pré-sinterizados do sistema Zirkonzahn (Zirkonzahn) foram seccionados de modo a produzir 90 blocos menores (5 x 4 x 3 mm). Os blocos foram polidos em Politriz com lixas d'água de granulação fina 1000 e 1200 (3M ESPE) e limpos em banho ultrassônico contendo álcool isopropílico a 96% durante 5 min. Após a sinterização dos blocos cerâmicos, foi realizada a aplicação do tratamento de superfície. O Rocatec Soft foi jateado com 2,8 bar, ângulo de incidência perpendicular e distância padrão de 10 mm por 25 s em movimentos circulares. O Akyzent Glaze Spray foi pulverizado por 2 s e em seguida sinterizado em forno Vacumat (Vita) de acordo com recomendações do fabricante. Após a aplicação de 1 gota do vidro bioativo, procedeu-se a secagem e sinterização a 1200 ºC deste material. Em todos os grupos aplicou-se agente de união silano Monobond-S (Ivoclar Vivadent). Nos grupos 3, 4, 5 e 6 a superfície foi primeiramente condicionada com ácido hidrofluorídrico (HF) a 5% durante 2 min, lavada e depois silanizada. A cimentação foi realizada com um dispositivo (Ultradent), produzindo cilindros de cimento resinoso com 2 x 1mm.! Após 24 h os espécimes foram envelhecidos em termocicladora com 5.000 ciclos com banhos de temperatura entre 5 e 55 ºC e submetidos ao ensaio de cisalhamento na Shear Bond Tester (Bisco). O VBA foi analisado qualitativamente por meio de análise térmica diferencial (DTA), através de difração de raios-x (DRX)(Panalytical) e espectroscopia de energia dispersiva de raio-x (EDS) (Oxford Instruments)... / Abstract: The bond strength of resin cements Panavia F (P) (Kuraray) and RelyX U200 (R) (3M ESPE) to zirconia using three different surface treatments: 1 - triboquemical silicatization (ST); 2 - glaze (G) 3 - bioactive glass (VBA) was compared. Blocks of Zirkonzahn system were cut producing 90 smaller blocks (5 x 4 x 3 mm). The blocks were polished with water finegrained 1000 and 1200 sandpaper in Politriz and cleaned with 96% isopropyl alcohol for 5 min. The Rocatec Soft was etched with 2.8 bar, in a perpendicular way and a distance of 10 mm for 25 s in a circular motion. The Akyzent Glaze Spray was sprayed by 2s and then sintered in oven Vacumat (Vita) according to manufacturer's recommendations. After application of 1 drop of bioactive glass, the material was dried and sintered at 1200 °C. In all groups was applied silane coupling agent Monobond- S (Ivoclar Vivadent). In groups 3, 4, 5 and 6 the surface was first etched with 5% hydrofluoric acid (HF) and then silanized. The cementing was carried out with a device (Ultradent), producing cured cement cylinders of 2 x 1mm. After 24 h the specimens were aged in thermocycler with 5,000 cycles at a temperature of 5 and 55 ºC and subjected to microshear test on Shear Bond Tester (Bisco). VBA was analyzed by means of DTA, XRD and EDS. Optical profilometry (PO) was performed to obtain roughness. After fracture the samples were analyzed through SEM. It was found that XRD revealed the formation of a glass ceramic film. DTA shows that the temperature of 1200 °C is the most suitable for sintering. DRX showed the formation of a glass ceramic film. According to ANOVA, the interaction effect was significant (p = 0.003 < 0.05). The test for multiple comparison of means, Tukey (5%) showed that the TBS (MPa) for VBA were significantly higher than the other groups (with 26.94 ± 3.50 to P and 28.36 ± 3.32 to R), regardless cement kind used. The lowest result... / Doutor
74

Análise de propriedades biológicas de materiais de interesse na Odontologia /

Camargo, Samira Esteves Afonso. January 2016 (has links)
Banca: Marcia Carneiro Valera / Banca: Luciane Dias de Oliveira / Banca: Brenda Paula Figueiredo de Almeida Gomes / Banca: Rodrigo Cardoso de Oliveira / Banca: Daniela Rios / Resumo: O objetivo desta tese foi reunir os resultados de estudos in vitro e in vivo que avaliaram as propriedade biológicas de materiais de interesse na Odontologia. Foram avaliados a biocompatibilidade de materiais para capeamento pulpar (1 estudo in vivo e 1 estudo in vitro), cimentos endodônticos (3 estudos in vitro) e dentifrícios (2 estudos in vitro). Dentre os materiais de capeamento pulpar, o polímero da mamona (COB) induziu in vivo menor inflamação subcutânea em ratos e apresentou in vitro alta viabilidade celular sobre células pulpares. O mineral trióxido agregado (MTA) branco mostrou proliferação celular em linhagens de V79 e em células pulpares. Os cimentos endodônticos apresentaram respostas biológicas diferentes dependendo de sua composição. O cimento a base de resina epóxi (AH Plus) e o cimento MTA Fillapex apresentaram moderada citotoxicidade e produziram baixa formação de micronúcleos. Os cimentos fitoterápicos a base de polímero da mamona (COP) e da Copaíba apresentaram alta viabilidade celular e não induziram nenhuma formação de micronúcleos, não sendo considerados citotóxicos e nem genotóxicos. Todos os dentifrícos com efeito clareador foram citotóxicos e o Oral B Whitening foi também genotóxico para fibroblastos. Dentre os dentifrícios dessensibilizantes foi verificado que o Colgate Sensitive foi o dentifrício menos citotóxico. Já, Oral B Sensitive e Sensodyne foram bastantes citotóxicos para os fibroblastos gengivais. Quanto à genotoxicidade, nenhum dentifrício dessensibilizante proporcionou formação de micronúcleos em fibroblastos. os dentifrícios dessensibilizantes apresentaram moderada atividade antimicrobiana para C. albicans, S. mutans e S. aureus. Como conclusão geral, os estudos mostraram que: a) os materiais fitoterápicos, como o COB e o COP apresentam boa biocompatibilidade in vivo e in vitro; b) o MTA branco induziu proliferação celular in vitro; c) os cimentos endodônticos.. / Abstract: The aim of this thesis was to assemble the results of in vitro and in vivo studies investigating the biological properties of materials of interest in dentistry. It was evaluated the biocompatibility of pulp capping materials (1 in vivo study and 1 in vitro study), sealers (3 in vitro studies) and toothpastes (2 in vitro studies). Among the pulp capping material, the castor oil bean (COB) induced in vivo subcutaneous less inflammation in rats and in vitro showed high cell viability of pulp cells. White mineral trioxide aggregate (MTA) showed cell proliferation in V79 cells and human pulp cells. The sealers showed different biological responses depending on their composition. The cement based on epoxy resin (AH Plus) and the MTA Fillapex cement showed moderate cytotoxicity and induced low formation of micronuclei. Phytotherapy sealers based on castor oil polymer (COP) and Copaifera showed high cell viability and did not induce any formation of micronuclei, not considered cytotoxic nor genotoxic. All whitening toothpastes were cytotoxic and Oral B Whitening was also genotoxic to gingival fibroblasts. Colgate Sensitive was the least cytotoxic among the desensitizing toothpastes. However, Oral B Sensitive and Sensodyne were quite cytotoxic to gingival fibroblasts. For genotoxicity, all desensitizing toothpastes provided no micronucleus formation in fibroblasts. These toothpastes showed moderate antimicrobial activity against C. albicans, S. mutans and S. aureus. As a general conclusion, the studies showed that: a) phytotherapy materials such as COB and COP exhibit good biocompatibility in vivo and in vitro; b) white MTA induced cell proliferation in vitro; c) the sealers have high to moderate cytotoxicity and genotoxicity depending on their composition; d) whitening toothpastes were cytotoxic and Oral B Whitening was also genotoxic; e) Colgate Sensitive was not cytotoxic and genotoxic and showed moderate antimicrobial activity
75

Adaptação marginal e remoção por tração de infraestruturas para metalocerâmica em função de diferentes términos cervicais, expulsividades e agentes cimentantes / Influence of finish line design, axial wall inclination angle and cement type on marginal fit and tensile strength of copings for metal ceramic restorations

Almeida, Juliana Gomes dos Santos Paes de 22 November 2010 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2010. / Submitted by Elna Araújo (elna@bce.unb.br) on 2011-05-10T21:30:43Z No. of bitstreams: 1 2010_JulianaGomesdosSantosPaesdeAlmeida.pdf: 1211245 bytes, checksum: 5c967c1cf42c5283407f96431f0f5713 (MD5) / Approved for entry into archive by Raquel Viana(tempestade_b@hotmail.com) on 2011-05-16T19:24:57Z (GMT) No. of bitstreams: 1 2010_JulianaGomesdosSantosPaesdeAlmeida.pdf: 1211245 bytes, checksum: 5c967c1cf42c5283407f96431f0f5713 (MD5) / Made available in DSpace on 2011-05-16T19:24:57Z (GMT). No. of bitstreams: 1 2010_JulianaGomesdosSantosPaesdeAlmeida.pdf: 1211245 bytes, checksum: 5c967c1cf42c5283407f96431f0f5713 (MD5) Previous issue date: 2010 / Não existe na literatura um consenso sobre a melhor técnica de preparo e o melhor agente cimentante para as próteses fixas metalocerâmicas, fatores estes que estão diretamente relacionados ao sucesso das mesmas. Levando-se em consideração a ampla utilização desse tipo de restauração na odontologia, este estudo avaliou a adaptação marginal e a remoção por tração de infraestruturas para metalocerâmica em função de diferentes términos cervicais, graus de expulsividade das paredes axiais e agentes cimentantes. Para isto, foram confeccionados troquéis em metal (NiCr) simulando preparos dentários de molares com diferentes términos cervicais (ombro e plano inclinado em 135°) e diferentes graus de expulsividade das paredes axiais (6° e 20°). Sobre esses troquéis foi posicionada uma matriz metálica que permitiu o enceramento de infraestruturas padronizadas, as quais foram fundidas em NiCr Dan Ceramalloy. Para a análise da adaptação marginal, leituras em estereomicroscópio (32X) foram realizadas em dois momentos: antes da cimentação (L0) e após a cimentação (L1) com diferentes agentes cimentantes: Fosfato de Zinco (S.S.White), RelyX U100 (3M-ESPE) e Panavia F (Kuraray). Os corpos de prova foram termociclados (5.000 ciclos: 5°C e 55°C), armazenados a seco em estufa a 37°C por 24 horas e, então, submetidos ao ensaio de remoção por tração realizado em máquina universal de ensaios mecânicos EMIC DL2000 (São José dos Pinhais, Paraná, Brasil), com célula de carga de 5 kN e velocidade do atuador de 0,5 mm/minuto. Considerando-se os dados da adaptação marginal, foram realizadas as seguintes análises comparativas: 1) entre os tipos de preparo (ANOVA-1 fator e Tukey); 2) entre antes e após a cimentação, realizado individualmente para cada tipo de preparo (teste t de Student); 3) entre os cimentos em função do tipo de preparo (Kruskal-Wallis e Dann) e 4) entre as doze combinações existentes (ANOVA-1 fator e Tukey). Antes da cimentação, os preparos ombro 6º (117,1), ombro 20º (126,05) e plano inclinado 6º (131,51) apresentaram as melhores médias de adaptação (μm). Para cada tipo de biomecânica testada, a adaptação marginal sempre apresentou maiores valores após a cimentação. Para os diferentes cimentos avaliados, apenas os preparos com o término plano inclinado apresentaram pior adaptação marginal quando o Panavia F foi utilizado. As melhores médias de adaptação após a cimentação foram apresentadas por todos os preparos do tipo ombro, pelo preparo plano inclinado 6º/Rely X U100 e Fosfato de Zinco e pelo preparo plano inclinado 20º/Rely X U100. Quanto à resistência à remoção por tração (MPa), os testes ANOVA-1 fator e Scheffe indicaram resistência significativamente maior em todos os tipos de preparo associados ao cimento Panavia F (15,08; 11,33; 10,90 e 10,16) e no plano inclinado 20º/Rely X U100 (9,99). Conclui-se que o tipo de término cervical, a expulsividade das paredes axiais do preparo e o agente de cimentação selecionado influenciam na adaptação marginal e na resistência à remoção por tração de infraestruturas em NiCr para metalocerâmica. ________________________________________________________________________________ ABSTRACT / There is no consensus in the literature about the best preparation technique and the best cementing agent for fixed metal ceramic dentures, these being factors directly related to their successful outcomes. Taking into consideration the extensive use of this type of restoration in dentistry, this study evaluated the influence of finish line design, axial-wall inclination angle and cement type on marginal fit and tensile strength for metal ceramic copings. For this purpose metal dies were fabricated (NiCr) simulating dental preparations in molars, with different cervical terminations (shoulder and sloping shoulder 135º) and different axial wall degrees (6° and 20°). A metal matrix was placed on these dies, to allow the waxing of standardized copings, which were cast in NiCr Dan Ceramalloy. For marginal fit analysis, readouts were made with a stereo microscope (32X) at two time intervals: before cementation (L0) and after cementation (L1) with different cementing agents: Zinc Phosphate (S.S.White), RelyX U100 (3M-ESPE) and Panavia F (Kuraray). The test specimens were thermal cycled (5,000 cycles: 5°C and 55°C), stored dry in an oven at 37°C for 24 hours, and then submitted to the test of tensile strength in a universal mechanical test machine EMIC DL2000 (São José dos Pinhais, Paraná, Brazil), with a load cell of 5 kN and crosshead speed of 0.5 mm/minute. Considering the marginal fit data, the following comparative analyses were performed: 1) between the types of preparation (ANOVA-1 factor and Tukey); 2) between the intervals before and after cementation, performed individually for each type of preparation (Student’s-t test); 3) among the cements as a function of the preparation form (Kruskal-Wallis and Dann) and 4) among the twelve existent combinations (ANOVA-1 factor and Tukey). Before cementation, the 6º shoulder (117.1), 20º shoulder (126.05) and sloping shoulder at 6º (131.51) preparations presented the best fit means (μm). For each biomechanical type tested, the marginal fit always presented higher values after cementation. For the different cements evaluated, only the preparations with sloping shoulder terminations presented worse marginal fit when Panavia F was used. The best fit means after cementation were presented by all preparations of the shoulder type; preparations with sloping shoulder at 6º /RelyX U100 and Zinc Phosphate, and sloping shoulder at 20º/RelyX U100. As regards to the tensile force (MPa), the ANOVA-1 factor and Scheffe tests indicated significantly higher resistance in all types of preparation associated with Panavia F cement (15.08; 11.33; 10.90 and 10.16) and in the sloping shoulder at 20º/RelyX U100 (9.99). It was concluded that the type of cervical termination, axial wall inclination and the cementing agent selected influenced the marginal fit and the tensile strength of NiCr copings for metal ceramic restorations.
76

Análise da limpeza dos túbulos dentinários após a desobturação do canal radicular / Analysis of the cleanness of the dentinal tubules after the clear of the root canal

Sarmento, Naelka 16 August 2018 (has links)
Orientador: Alexandre Augusto Zaia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T14:55:33Z (GMT). No. of bitstreams: 1 Sarmento_Naelka_M.pdf: 4681309 bytes, checksum: 93b3b378f28c8753a75a32deec716bcd (MD5) Previous issue date: 2010 / Resumo: O objetivo desse trabalho foi analisar a limpeza de túbulos dentinários após a desobturação do canal radicular com ou sem o uso de eucaliptol, através de microscopia eletrônica de varredura. Foram empregados neste estudo 100 raízes de primeiros molares superiores e inferiores. Como critério de inclusão as raízes selecionados deveriam apresentar-se retilínea, sem cáries, fissuras ou fraturas radiculares. O preparo químico-mecânico foi realizado com solução de hipoclorito de sódio 5% e EDTA 17% ou clorexidina gel 2% e EDTA 17%. As 100 raízes foram divididas em 5 grupos (Grupo A, B, C, D e E) aleatoriamente, as quais foram obturadas com cimentos endodônticos Endométhasone-N, Sealapex, AH Plus e Epiphany. Decorrido o tempo de pressa conforme recomendação do fabricante foi realizada a desobturação com eucaliptol para os subgrupos A1, B1, C1, D1 e E1; e sem o uso de eucaliptol, usando somente água destilada para os subgrupos A2, B2, C2, D2 e E2. As raízes foram fraturadas no eixo longitudinal e analisadas em microscópio eletrônico de varredura (SEM). Quando se fez uso de solvente os cimentos resinosos apresentaram melhor limpeza nas regiões cervical e média. Os cimentos a base de óxido de zinco e eugenol apresentaram limpeza precária nos terços médio e apical quando desobturados com água. O terço apical mostrou maior quantidade de detritos independente do cimento utilizados, fazendo-se ou não o uso de solventes / Abstract: The aim of this study was to analyze the cleanliness of the dentinal tubules after root canal removal procedure with or without the use of eucalyptol, by scanning electron microscopy (SEM). Used in this study were 100 roots of the first upper and lower molars. The inclusion criterion roots selected should present itself straight, no cavities, cracks or root fractures. The chemo-mechanical preparation was accomplished with a solution of sodium hypochlorite 5% and EDTA 17% or chlorhexidine gel 2% and 17% EDTA. The 100 roots were divided into five groups (Group A, B, C, D and E) randomly, which were sealed with sealers Endométhasone-N, Sealapex, AH Plus and Epiphany. Elapsed time to setting as recommended by the manufacturer was performed with the removal procedure eucalyptol for subgroups A1, B1, C1, D1, E1, and without the use of eucalyptol, using only distilled water for subgroups A2, B2, C2, D2 and E2. The roots were fractured in the longitudinal axis and analyzed by scanning electron microscopy (SEM). When use was made of solvent resin sealer showed better cleaning in the cervical and middle. The sealer of zinc oxide and eugenol showed poor cleaning in the middle and apical thirds when unstop with water. The apical third showed a larger amount of debris regardless of the cement used, making it or not the use of solvents / Mestrado / Endodontia / Mestre em Clínica Odontológica
77

Efeito do método de ativação na resistência à flexão e no módulo de elasticidade de cimentos resinosos duais / Effect of activation mode on flexural strength and modulus of elasticity of resin luting cements

Guimarães, Isadora Rabêlo, 1985- 18 August 2018 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:45:07Z (GMT). No. of bitstreams: 1 Guimaraes_IsadoraRabelo_M.pdf: 3888113 bytes, checksum: 25237d2005928cbeda35da2ee6ff2357 (MD5) Previous issue date: 2011 / Resumo: Este estudo avaliou o efeito do método de ativação na resistência à flexão e módulo de elasticidade de quatro cimentos de dupla cura à base de metacrilato. Dois cimentos resinosos auto-adesivos (Clearfil SA Cement (CSA) e RelyX U100 (U)) e dois cimentos convencionais (Clearfil Esthetic Cement (CE) e RelyX ARC (ARC)) foram usados para produzir um total de 45 amostras em forma de barra (7 mm de comprimento x 2 mm de largura x 2 mm de espessura) usando três diferentes modos de ativação (n = 15): fotoativação direta (D), fotoativação indireta com anteparo de resina composta 2 mm (I) e polimerização química (Q). O teste dos três pontos foi realizado após 24 horas de armazenamento em água deionizada a 37°C utilizando uma máquina universal de ensaio (Instron) a uma velocidade transversal de 0,5 mm / min até a fratura. Os valores de resistência à flexão (MPa) e módulo de elasticidade (GPa) foram submetidos aos testes ANOVA e Tukey ('alfa' =. 05). Os dados revelaram que os grupos ativados pela luz apresentaram valores estatisticamente maiores de resistência à flexão (CSA / D = 113,6 ± 19,6; CSA / I = 80,6 ± 23,7; U / D = 101,3 ± 9,8; U / I = 94,9 ± 36,9; CE / D = 219,0 ± 39,9; CE / I = 226,4 ± 34,5, ARC / D = 150,0 ± 26,1, ARC / I = 111,7 ± 14,2) e módulo de elasticidade (CSA / D = 2,9 ± 0,6; CSA / I = 1,5 ± 0,4; U / D = 2,9 ± 0,5; U / I = 2,6 ± 1,4; CE / D = 6,5 ± 1,3; CE / I = 5,8 ± 1,0; ARC / D = 4,2 ± 0,9; ARC / I = 2,5 ± 0,5) comparado aos grupos de polimerização química (CSA / Q = 65,8 ± 21,8; U / Q = 53,6 ± 28,7; CE / Q = 129,0 ± 51,6, ARC / Q = 77,9 ± 19,6) (CSA / Q = 1,4 ± 0,5; U / Q = 1,2 ± 0,7; CE / Q = 2,2 ± 1,5; ARC / Q = 1,0 ± 0,5). O uso do anteparo de resina composta atenuou a transmissão de luz para o ARC e CSA. Os cimentos resinosos convencionais apresentaram maiores valores de resistência à flexão em relação aos cimentos auto-adesivos. CE apresentou os maiores valores em relação a todos os outros cimentos analisados. Não houve diferença estatística entre os cimentos auto-adesivos. A fotoativação dos cimentos resinosos aumentou a resistência à flexão de todos os materiais avaliados. Comportamento mecânico semelhante foi observado entre os cimentos auto-adesivos / Abstract: Aim: This study evaluated the effect of the activation mode on flexural strength of four dual cure resin-based cements. Method: Two self-adhesive resin cements (Clearfil SA Cement (CSA) and RelyX U100 (U)) and two conventional resin cements (Clearfil Esthetic Cement (CE) and RelyX ARC (ARC)) were used to produce a total of 45 bar specimens (7x2x2 mm) using three different activation modes (n=15): Direct light-cure (D), Indirect light-cure using a 2mm composite resin barrier (I) and Self-cure (S). Three-point bending tests were performed after 24 hours of storage at 37° C using a universal testing machine (Instron) at a cross-speed of 0.5 mm/min until fracture. Flexural strength (MPa) and modulus of elasticity (GPa) values were subjected to ANOVA and Tukey's Test ('alfa'=.05). Results: Data revealed that groups activated by light presented statistically higher values for flexural strength (CSA/D=113.6 ± 19.6; CSA/I=80.6 ± 23.7; U/D=101.3 ± 9.8; U/I=94.9 ± 36.9; CE/D=219.0 ± 39.9; CE/I=226.4 ± 34.5; R/D=150.0 ± 26.1; R/I=111.7 ± 14.2) and modulus of elasticity (CSA/D = 2.9 ± 0.6; CSA/I = 1.5 ± 0.4; U/D = 2.9 ± 0.5; U/I = 2.6 ± 1.4; CE/D = 6.5 ± 1.3; CE/I = 5.8 ± 1.0; ARC/D = 4.2 ± 0.9; ARC/I = 2.5 ± 0.5) compared to self-cure groups (CSA/S=65.8 ± 21.8; U/S=53.6 ± 28.7; CE/S=129.0 ± 51.6; R/S=77.9 ±19.6) (CSA/Q = 1.4 ± 0.5; U/Q = 1.2 ± 0.7; CE/Q = 2.2 ± 1.5; ARC/Q = 1.0 ± 0.5). The use of a composite resin barrier affected light transmission for R and CSA. Conventional resin luting cements presented the highest values for flexural strength compared to self-adhesive cements. CE presented the highest values compared to all other tested cements. No statistical difference was observed between self-adhesive cements. Conclusion: Light-curing of resin luting cements increased flexural strength for all tested materials. Similar mechanical behavior was observed for the tested self-adhesive cements / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
78

Avaliação de deposição superficial de corante em ionomeros de vidro modificados por resina submetidos a tratamentos superficiais

Liporoni, Priscila Christiane Suzy 26 September 1997 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T19:00:05Z (GMT). No. of bitstreams: 1 Liporoni_PriscilaChristianeSuzy_M.pdf: 2141251 bytes, checksum: a3ac5173dc3d07b4b25bd1c21f88f27b (MD5) Previous issue date: 1997 / Resumo: O acabamento e polimento de restaurações diretas são essenciais para se obter uma lisura superficial adequada. O propósito deste estudo foi avaliar "in vitro" a deposição superficial de corante em ionômeros de vidro modificados por resina quando submetidos a diferentes tratamentos superficiais de acabamento e polimento. Os materiais foram manipulados de acordo com as instruções dos fabricantes, inseridos em uma matriz de acrílico, cobertos com uma tira de poliéster e fotopolimerizados. Vinte e quatro amostras de cada material, Photac-Fil ( Espe ) e Fuji II LC ( GC Corporation ) foram divididas em três grupos: Tira matriz ( GC ); Pontas Enhance ( GI ); Discos Sof-Iex fino e extra-fino ( Gil ). Todas as amostras foram submetidas ao teste de manchamento através do corante azul de metileno e quantificados num espectrofotômetro. Foi feita a Análise de Variância para comparação entre as médias e então aplicado o Teste de Tukey ( a = 0,05% ). As médias (Jlg/ rnl) para cada material foram: Photac-Fil, GC = 0,999; GI = 1,175; Gil = 1,157 e Fuji II LC, GC = 0,0~01; GI = 0,547; GIl = 0,0001. Concluiu-se que a melhor superfície foi obtida quando os materiais polimerizaram junto à tira matriz. Entre os materiais utilizados no acabamento e polimento, os discos Sof-Iex apresentaram melhores resultados para o híbrido Fuji II LC / Abstract: Finishing is essential to obtain appropriate smooth surfaces of direct restorations increasing the longevity of them. The purpose of this study was to evaluate "in vitro" superficial dye deposition on resin modified glass-ionomer submitted to different surface finishing treatments. The materiaIs were mixed following the manufactures directions, inserted into split molds, covered with a matrix strip and polymerized. Twenty-four samples of the each material, Photac-fil ( Espe ) and Fuji 11 LC ( GC Corporation ) were divided into three finishing groups: (I) Mylar matrix ( control); (11) disks Sof-Iex ( fine and ultra-fine); (111) Enhance system. AlI samples were submitted to staining test by dye uptake and were quantified by spectrophotometry. The results were analysed by ANOV A and Tukey's test. The means Ü.lg! rnl) for each material were: Photac-Fil, GC = 0,999; GI = 1,175; GIl = 1,157 and Fuji 11 LC, GC = 0,0001; GI = 0,547; GIl = 0,0001. It was concluded that the best surface was obtained when the materiaIs were cured in contact with the Mylar matrix strip. Among the materials used for surface finishing Sof-Iex presented the best results to Fuji 11 LC / Mestrado / Dentística / Mestre em Clínica Odontológica
79

Resistencia a tração da porcelana sob influencia de materiais cimentantes

Carvalho, Christiane Martins de Lanna Salles 08 September 1997 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T21:31:33Z (GMT). No. of bitstreams: 1 Carvalho_ChristianeMartinsdeLannaSalles_M.pdf: 3513862 bytes, checksum: bd92d1818f3145a39d79f448b471a2d5 (MD5) Previous issue date: 1997 / Resumo: A resistência à tração da porcelana sob influência de materiais cimentantes foi avaliada em 48 discos cerâmicos (Ouceram Oegussa) de 20,75 mm de diâmetro por 1,28 mm de espessura. As amostras foram divididas em 6 grupos: A - Amostras sem tratamento de superfície ou aplicação de material cimentante; B- A superfície não glazeada da amostra foi condicionada com ácido fluorídrico a 10% por 4 minutos; C - Procedimento similar ao do grupo B, seguido da aplicação do silano, adesivo e de cimento resinoso Choice Porcelain (Bisco); O - Procedimento similar ao grupo C, e aplicação do cimento resinoso (Resin Cement-3M); E Superfície não condicionada e utilização de cimento de fosfato de zinco(S.S.White); F- Superfície não condicionada e aplicação do Vitremer para cimentação (3M). Os corpos de prova foram armazenados por 24 horas a 37° C e 100% de umidade relativa. A seguir, foram posicionados na máquina MTS para a realização do ensaio de flexão através do teste biaxial, à velocidade de 2mm/min. Os valores obtidos foram submetidos à Distribuição de Weibull. Os valores médios de resistência à fratura foram: Grupo A=13,20 MPa; B=10,19 MPa; C=178,26 MPa; 0=154,96 MPa; E=125,59 MPa; F=128; 13 MPa. A resistência à tração da porcelana variou de acordo com o material cimentante e foi maior quando utilizada a associação condicionamento áciao/sistema adesivo/cimento resinoso / Abstract: The tensile strength of porcelain under the influence of luting cement was verified in forty-eight ceramic discs measuring 20.77 mm in diameter and 1.28 mm in thick, using Ouceram porcelain (Oegussa). The specimens were randomly divided into six groups: A - The specimens did not receive any treatment or IltIting cemen~; 8 The non glazed surface of the specimen was etched with a hidrofluoridric acid àt 10% for 4 minutes; C - Sil1i1ilar procedure of group 8, followed by the coating of silane/adhesive/resin cement (Choice Porcelain - 8isco); O - Similar pliocedure of group C, except that the ceramic surface was coated with Resin Cement (3M); E The ceramic surface was not etched and it was coated with zinc phosphate (S.S.White); F - The ceramic surface was not etched and it was coated with Vitremer Cement (3M). The specimens were stored. at 37°C and 100% relative humidity for 24 hours. Then, the biaxial test was carried by submiting the specimens to compressive stress on the MTS machine at crosshead of 2mm/min.The original' values were submited to the Weibull Oistribution. The mean values were: Group A=13.20 MPa; Group 8=10.19 MPa, Group C=178.63 MPa;Group 0=154.96 MPa; Group E=125.59 MPa; Group F=128.13 MPa. The porcelain tensi'le strength varied according with the luting cement and it was higher when the association acid etching/adhesive system/ luting resin cement was used. / Mestrado / Materiais Dentarios / Mestre em Ciências
80

Avaliação clinica de materiais hibridos de ionomero de vidro resina composta utilizados como selantes de fossulas e fissuras

Luca Fraga, Luciola Rangel de 21 October 1997 (has links)
Orientador: Luiz Andre Freire Pimenta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontlogia de Piracicaba / Made available in DSpace on 2018-07-22T22:10:08Z (GMT). No. of bitstreams: 1 LucaFraga_LuciolaRangelde_M.pdf: 2708746 bytes, checksum: 263e8cde6b81530b4f48917819c3f732 (MD5) Previous issue date: 1997 / Resumo: O objetivo deste estudo foi avaliar clinicamente os materiais híbridos de ionômero de vidro/resina composta, Vitremer (3M) e Dyract (Dentsply), quando utilizados como sei antes de fóssulas e fissuras. Para tanto, foram utilizados os primeiros molares permanentes inferiores de cem crianças na faixa etária de sete e oito anos, sendo um dos materiais utilizado no elemento esquerdo e o outro no direito, alternadamente. Decorridos seis e doze meses do selamento, foi efetuada a avaliação clínica e a análise comparativa dos materiais, quanto à retenção e à capacidade de prevenção de cárie em relação a um grupo controle não selado. Os resultados da análise estatística demonstraram a semelhança de desempenho entre os materiais no período de seis meses.. quanto à retenção. Aos doze meses as avaliações clínicas demonstraram índices de 95,9% e 85,7% de retenção para o Dyract e o Vitremer respectivamente, implicando em uma diferença estatisticamente significativa entre os materiais (OR > 1). Os materiais híbridos demonstraram efeito protetor contra a cárie estatisticamente significante em relação ao grupo controle, aos seis e doze meses (OR < 1) / Abstract:The aim of this study was to evaluate the clinical performance of two glass ionomer/resin composite hybrid materiais, when applied as pits and fissures sealants. The mandibular first permanent molars on one side of dental arch in 100 children were sealed with Vitremer (3M), and the same teeth on the other side were sealed with Dyract (Dentsply). Six and twelve months after placement, examiners documented sealant retention and caries prevention in relation to an unsealed contrai group. The results, supported by statistical analysis, showed similarity betwen the material's perfomance afier six months. At one year, the retention of the Vitremer (3M) Was significantly less (OR) than the Dyract (Dentsply), the rates of complete retention were 95.9% and 85.7% fqr Dyract and Vitremer respectively. The caries preventive effect of hybrid materiais in sealed group was significantly different (OR<1) in comparison with the unsealed group, at six and twelve months / Mestrado / Dentística / Mestre em Clínica Odontológica

Page generated in 0.2182 seconds