• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 51
  • 51
  • 51
  • 45
  • 43
  • 22
  • 21
  • 14
  • 14
  • 11
  • 11
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Aplicação de ondas de ultra-som sobre cimentos de ionômero de vidro : rugosidade superficial e perda de massa após ensaio de escovação /

Coldebella, Cármen Regina. January 2007 (has links)
Orientador: Ângela Cristina Cilense Zuanon / Banca: José Luiz Guimarães Figueiredo / Banca: Lourdes Aparecida Martins dos Santos-Pinto / Resumo: Este trabalho teve como objetivo determinar a influência da excitação ultra-sônica aplicada em dois cimentos de ionômero de vidro nos momentos inicias de sua reação de presa, avaliando a rugosidade superficial e a perda de massa após ensaio de escovação. Os materiais foram o Fuji IX GP (GC Corporation) e Ketac Molar Easymix (3M ESPE), manipulados de acordo com as instruções dos fabricantes e inseridos em matriz confeccionada com dente bovino. Foram confeccionados 16 espécimes de cada material, dos quais a metade recebeu excitação com ondas de ultra-som (PROFI III BIOS - Dabi Atlante) por um período de 30 segundos. Todos os corpos foram pesados diariamente, em balança analítica (Sartoruis), até a estabilização de sua massa, a qual foi alcançada após 20 dias da manipulação. Logo após foi realizada a leitura da rugosidade inicial (rugosímetro Surfcorder SE 1700 - Japão). Em seguida os mesmos foram submetidos ao ensaio de escovação, totalizando 30.000 ciclos. Nova leitura de rugosidade superficial e seqüência de pesagem foram realizadas. Para a análise estatística foram utilizados os testes de Análise de Variância (MANOVA) e t-Student onde a diferença estatística foi determinada por p= 0,05. Observou-se diferença estatística significante na rugosidade superficial antes e após o ensaio de escovação (p= 0,00). Porém não houve diferença estatística na rugosidade quando considerada a aplicação de ondas de ultra-som (p= 0,06). A média de rugosidade após ensaio de escovação para o Fuji IX GP foi de 0,767æm e 0,643æm com e sem a aplicação de ondas de ultra-som respectivamente e para o Ketac Molar Easymix esses valores foram de 0,759æm e 0,757æm para as mesmas condições experimentais. Na interação material, excitação ultra-sônica e ensaio de escovação foi observada diferença... Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this work was to determine the influence of ultrasonic excitation in two glass ionomer cements (GICs) evaluating the superficial roughness and mass loss after toothbrushing test. The GICs tested were Fuji IX GP (GC Corporation) and Ketac Molar Easymix (3M ESPE). The cements were manipulated according to the manufacturesþ instructions and inserted in a bovine tooth matrix. For each material 16 specimens were made. Eight specimens of them were excited with ultrasonic waves (PROFI III BIOS - Dabi Atlante) for 30s. All specimens were weighed daily in an analytical balance (Sartoruis) until their mass stabilization which was reached after twenty days. Next, the initial superficial roughness reading was performed (Surfcorder SE 1700 - Japan). After that, toothbrushing test was performed, and 30.000 cycles were applied. Soon after, a new superficial roughness reading and a sequence of weighing were performed. The statistical analysis was made through MANOVA test and t-Student where p= 0.05 determined a significant statistical difference. A difference on the superficial roughness was observed before and after toothbrushing (p=0.00). However, there was no statistical difference when the ultrasonic waves were used (p=0.06). After toothbrushing test Fuji IX GP roughness average was 0.767æm and 0.643æm with and without the use of ultrasound waves respectively while Ketac Molar Easymix showed 0.759æm and 0.757æm in the same experimental conditions. In the interaction: material, ultrasonic excitation, and toothbrushing test, a significant statistical difference was observed (p=0.004) which was due to the toothbrushing test and not to the use of ultrasonic waves. The mean of weigh loss was 0.45mg for Fuji IX GP with ultrasound excitation, and 0.61mg without this procedure; Ketac Molar Easymix showed 0.27mg and 0.16mg respectively. However, there was no statistica... (Complete abstract, click electronic access below) / Mestre
42

Efeito de diferentes protetores de superfície na resistência à tração diametral e na liberação de flúor nos cimentos ionoméricos tipo II / Effect of different protective coatings on the fluoride release and on the diametral tensile strength of two conventional restorative glass ionomer cements

Thiago Moitrel Pequeno da Silva 10 December 2007 (has links)
Neste estudo avaliou-se o efeito de diferentes protetores de superfície na liberação de flúor (LF) e na resistência à tração diametral (TD) de dois cimentos de ionômero de vidro (CIV) convencionais restauradores, Chemfil e Chemflex (Dentsply). Manipulou-se os cimentos segundo as recomendações do fabricante, os espécimes confeccionados foram divididos em cinco grupos: grupo1 sem protetor (controle); grupo2 vaselina sólida; grupo3 verniz (Cavitine, S.S.White); grupo4 verniz fluoretado (Duraflur, Denstply); grupo5 adesivo (Magic Bond, Vigodent). Confeccionou-se para o teste de LF 40 espécimes para cada CIV, com dimensões de 4 mm de diâmetro por 6 mm de comprimento, divididos aleatoriamente entre os grupos e estocados individualmente em potes plásticos contendo 5 ml de água deionizada. Registrou-se o nível de fluoreto no período de 04 horas, 24 horas, 03 dias, 07 dias e 14 dias após a confecção, em um analisador Expandable Íon Analyser EA 960, sendo os resultados calculados em &#956;gF/ cm2. Confeccionou-se para o ensaio de TD 120 espécimes para cada CIV, com dimensões de 4 mm de diâmetro por 6 mm de comprimento, divididos aleatoriamente entre os grupos. Realizou-se ensaios mecânicos, com 1 dia e 14 dias após a confecção e estocagem individual dos espécimes em potes plásticos contendo 5 ml de água deionizada, em uma máquina universal de ensaios EMIC DL 500 MF, realizou-se um terceiro teste após 14 dias de ciclos de des-remineralização. Tratou-se estatisticamente os dados obtidos por ANOVA e por Student Newman-Keuls (p<0,05). No teste de LF os resultados demonstraram que o Chemfil liberou uma quantidade significantemente maior de flúor do que o Chemflex. Durante o período do teste a vaselina e o verniz tiveram um comportamento semelhante, mostrando uma menor LF do que o grupo controle nas primeiras 4 horas, com uma maior liberação na análise seguinte (24 horas). Os espécimes protegidos com vaselina e verniz, tiveram uma liberação de flúor semelhante ao grupo controle nos períodos de 3, 7 e 14 dias. O verniz fluoretado mostrou uma forte influência nas primeiras 24 horas. A partir da terceira análise observou-se uma maior liberação de flúor para o Chemfil em comparação com o Chemflex. Em relação ao emprego de um protetor superficial resinoso, encontrou-se tanto para Chemfil quanto para o Chemflex uma redução drástica na liberação de fluoreto, em todos os tempos analisados. No ensaio de TD o Chemfil não mostrou diferença estatisticamente significante quando os resultados de TD do seu grupo controle foram avaliados nos diferentes ensaios (24 horas, 14 dias e des-re), o mesmo acontecendo com o Chemflex. Ao se avaliar a influência dos diferentes protetores de superfície nos CIVs utilizados no presente trabalho observou-se que, para o Chemfil os protetores de superfície tiveram pouca influência no comportamento do material, se comportando na maioria das vezes de forma similar ao grupo controle. Em contrapartida, para o material Chemflex a utilização de um protetor de superfície, como o verniz fluoretado e o adesivo, permitiu maiores valores de resistência à TD. Conclui-se que quando se objetiva o uso do CIV por um curto período o Chemfil sem protetor parece ser o mais indicado, porém se o uso do CIV for por um longo período o Chemflex com a proteção do verniz fluoretado é o mais indicado. / This study evaluated the effect of different protective coatings on the fluoride release (FR) and on the diametral tensile strength (DTS) of two conventional restorative glass ionomer cements (GIC), Chemfil e Chemflex (Dentsply). The cements were manipulated according to the manufacturer's recommendation. The especimens were divided into five groups: group 1 uncoated (control group); group 2 petroleum jelly; group 3 dental varnish (Cavitine, S.S.White); group 4 - fluoride varnish (Duraflur, Denstply); group 5 dentin adhesive (Magic Bond, Vigodent). To the FR test were made 40 especimens to each CIV, with dimensions of 4mm in diameter by 6 mm in length divided randomly into the groups and kept individually in plastic containers with 5 mL of deionized water. The fluoride level was registered within 04 hours, 24 hours, 3 days, 7 days and 14 days after the confection in an Expandable Íon Analyser EA 960, and the results were calculated in &#956;gF/ cm2. To the DTS test 120 especimens were made to each GIC, with dimensions of 4mm in diameter by 6mm in length divided randomly into the groups. Mechanical tests were made within 1 day and 14 days after the confection and saving of specimens individually in plastic containers with 5 mL of deionized water, in an universal tests machine EMIC DL 500 MF, and a third test was made after 14 days of des-remineralization cycles. The data was statistically treated by ANOVA and by Student Newman-Keuls (p<0,05). In the FR test the results showed that the Chemfil released a significant bigger amount of fluoride then the Chemflex. During the tests period, the petroleum jelly and the dental varnish had a similar behavior, presenting lower fluoride release then the control group in the first 4 hours, with a greater release in the second analysis (within 24 hours). The especimens protected by petroleum jelly and dental varnish had a fluoride release similar to the control group on the periods of 3, 7 and 14 days. The fluoride varnish showed a great influence in the first 24 hours. From the third analysis on, each ionomer materials characteristics became prominent, and was noticed a bigger fluoride release on the Chemfil in comparison to the Chemflex. In relation to the coated with dentin adhesive, there was a drastic decrease of fluoride release for Chemfil and Chemflex, in all of the analysis periods. In the DTS test Chemfil didnt show statistically significant difference when the diametral tensile strength of the control group was evaluated in the various periods of time (24 hours, 14 days and de-remineralization), which also happened to Chemflex. When evaluating the influence of different surface protectors on the GIC used at this study, it was noticed that for the Chemfil the surface coating had little influence on the materials behavior, having on most of the time, the same behavior as the control group. However, to the Chemflex material, the use of a surface coating such as the fluoride varnish or the dentin adhesive allowed bigger values of diametral tensile strength. The conclusion is that when the use of GIC is wanted for a short period of time the Chemfil uncoated seems the most indicated. However, if the period of use is longer, the Chemflex with the fluoride varnish protection is the most indicated.
43

Avaliação da interface dentina/agentes protetores em restaurações com resina composta, através de microscopia eletrônica de varredura

Peliz Fernandes, Maria Inez Lemos [UNESP] 17 October 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-10-17Bitstream added on 2014-06-13T20:41:43Z : No. of bitstreams: 1 pelizfernandes_mil_dr_arafo.pdf: 974117 bytes, checksum: ac5bfc8ea4cf08f87cfa61b609255346 (MD5) / O objetivo deste estudo foi avaliar a formação de microfendas entre diferentes agentes de proteção do complexo dentina-polpa e a estrutura dental. Cavidades de classe V, com dimensões padronizadas, foram preparadas nas faces V e L de 60 terceiros molares humanos recém-extraídos, divididos em 6 grupos: (1) Single Bond-SB, 3M ESPE; (2) Life-LF, Kerr Co.+ SB; (3) LF+Vitrebond-VT, 3M ESPE +SB; (4) VT+SB; (5) SB+VT; (6) SB+VT+SB; e restauradas com resina composta microhíbrida Filtek Z250 (3M ESPE), segundo as normas estabelecidas pelos fabricantes, exceto para os grupos 5 e 6 onde a dentina foi hibridizada previamente à aplicação do ionômero de vidro modificado por resina. Após ciclagem térmica, um segmento longitudinal de 800 æm de espessura foi obtido da porção central de cada restauração e, em seguida, submetidos às etapas de fixação, desidratação em grau ascendente de etanol e secagem através de HMDS. A adaptação interna dos materiais à parede axial foi analisada através do MEV, com 1000x de magnificação. Os dados obtidos foram analisados através do procedimento estatístico não-paramétrico de Kruskal-Wallis (p<0.05). O cimento de hidróxido de cálcio e ionômero de vidro modificado por resina aplicados sozinhos ou em conjunto (p<0.001), sob restauração de resina composta, resultou em microfendas com amplitude estatisticamente maiores do que quando a dentina foi somente hibridizada previamente a restauração. A hibridização dentinária permitiu selamento superior da interface dentina/restauração do que os demais agentes protetores avaliados. / The objective of this study was to evaluate the microgap with different materials used for pulp protection. The null hypothesis tested in this in vitro study was that the combination among calcium hydroxide, resin-modified glass ionomer and dentin adhesive, used as pulp protection in composite restorations would not result in greater axial gap than that obtained by hybridization only. Standardized class V preparations were performed in buccal and lingual surfaces of sixty caries-free extracted human third molars. The prepared teeth were randomly assessed in 6 groups: (1) Single Bond-SB, 3M ESPE; (2) Life-LF, Kerr Co.+ SB; (3) LF+Vitrebond-VT, 3M ESPE +SB; (4) VT+SB; (5) SB+VT; (6) SB+VT+SB; and restored with a microhybrid composite resin Filtek Z250 (3M ESPE), following the manufacturer's instructions. Except for group 5 and 6, which the ethanol- and water-based adhesive were applied prior the resin-modified glass ionomer. The specimens were then cross-sectioned with a thickness of 800 æm, fixed, dehydrated in ascending ethanol, and dried by means HMDS. The specimens were mounted in stubs, sputter coated and the internal adaptation of the materials to the axial wall analyzed under SEM with 1,000x magnification. The data obtained were analyzed with nonparametric tests (Kruskal-Wallis, p<0.05). The null hypothesis was rejected. Calcium hydroxide and resin-modified glass ionomer applied alone or in conjunction (p<0.001), under composite resin restoration, resulted in statistically wider micro gaps than when the dentin was only hybridized prior the restoration. Dentin hybridization provides superior sealing of the dentin and restoration interface than other pulp protection materials.
44

Avaliação da interface dentina/agentes protetores em restaurações com resina composta, através de microscopia eletrônica de varredura /

Peliz Fernandes, Maria Inez Lemos. January 2003 (has links)
Orientador: Sillas Luiz Lordelo Duarte Júnior / Banca: Welingtom Dinelli / Banca: Marcelo Ferrarezi de Andrade / Banca: José Roberto Cury Saad / Banca: Manio de Carvalho Tibúrcio / Banca: Camilo Anauate Netto / Resumo: O objetivo deste estudo foi avaliar a formação de microfendas entre diferentes agentes de proteção do complexo dentina-polpa e a estrutura dental. Cavidades de classe V, com dimensões padronizadas, foram preparadas nas faces V e L de 60 terceiros molares humanos recém-extraídos, divididos em 6 grupos: (1) Single Bond-SB, 3M ESPE; (2) Life-LF, Kerr Co.+ SB; (3) LF+Vitrebond-VT, 3M ESPE +SB; (4) VT+SB; (5) SB+VT; (6) SB+VT+SB; e restauradas com resina composta microhíbrida Filtek Z250 (3M ESPE), segundo as normas estabelecidas pelos fabricantes, exceto para os grupos 5 e 6 onde a dentina foi hibridizada previamente à aplicação do ionômero de vidro modificado por resina. Após ciclagem térmica, um segmento longitudinal de 800 æm de espessura foi obtido da porção central de cada restauração e, em seguida, submetidos às etapas de fixação, desidratação em grau ascendente de etanol e secagem através de HMDS. A adaptação interna dos materiais à parede axial foi analisada através do MEV, com 1000x de magnificação. Os dados obtidos foram analisados através do procedimento estatístico não-paramétrico de Kruskal-Wallis (p<0.05). O cimento de hidróxido de cálcio e ionômero de vidro modificado por resina aplicados sozinhos ou em conjunto (p<0.001), sob restauração de resina composta, resultou em microfendas com amplitude estatisticamente maiores do que quando a dentina foi somente hibridizada previamente a restauração. A hibridização dentinária permitiu selamento superior da interface dentina/restauração do que os demais agentes protetores avaliados. / Abstract: The objective of this study was to evaluate the microgap with different materials used for pulp protection. The null hypothesis tested in this in vitro study was that the combination among calcium hydroxide, resin-modified glass ionomer and dentin adhesive, used as pulp protection in composite restorations would not result in greater axial gap than that obtained by hybridization only. Standardized class V preparations were performed in buccal and lingual surfaces of sixty caries-free extracted human third molars. The prepared teeth were randomly assessed in 6 groups: (1) Single Bond-SB, 3M ESPE; (2) Life-LF, Kerr Co.+ SB; (3) LF+Vitrebond-VT, 3M ESPE +SB; (4) VT+SB; (5) SB+VT; (6) SB+VT+SB; and restored with a microhybrid composite resin Filtek Z250 (3M ESPE), following the manufacturer's instructions. Except for group 5 and 6, which the ethanol- and water-based adhesive were applied prior the resin-modified glass ionomer. The specimens were then cross-sectioned with a thickness of 800 æm, fixed, dehydrated in ascending ethanol, and dried by means HMDS. The specimens were mounted in stubs, sputter coated and the internal adaptation of the materials to the axial wall analyzed under SEM with 1,000x magnification. The data obtained were analyzed with nonparametric tests (Kruskal-Wallis, p<0.05). The null hypothesis was rejected. Calcium hydroxide and resin-modified glass ionomer applied alone or in conjunction (p<0.001), under composite resin restoration, resulted in statistically wider micro gaps than when the dentin was only hybridized prior the restoration. Dentin hybridization provides superior sealing of the dentin and restoration interface than other pulp protection materials. / Doutor
45

Efeito de diferentes protetores de superfície na resistência à tração diametral e na liberação de flúor nos cimentos ionoméricos tipo II / Effect of different protective coatings on the fluoride release and on the diametral tensile strength of two conventional restorative glass ionomer cements

Thiago Moitrel Pequeno da Silva 10 December 2007 (has links)
Neste estudo avaliou-se o efeito de diferentes protetores de superfície na liberação de flúor (LF) e na resistência à tração diametral (TD) de dois cimentos de ionômero de vidro (CIV) convencionais restauradores, Chemfil e Chemflex (Dentsply). Manipulou-se os cimentos segundo as recomendações do fabricante, os espécimes confeccionados foram divididos em cinco grupos: grupo1 sem protetor (controle); grupo2 vaselina sólida; grupo3 verniz (Cavitine, S.S.White); grupo4 verniz fluoretado (Duraflur, Denstply); grupo5 adesivo (Magic Bond, Vigodent). Confeccionou-se para o teste de LF 40 espécimes para cada CIV, com dimensões de 4 mm de diâmetro por 6 mm de comprimento, divididos aleatoriamente entre os grupos e estocados individualmente em potes plásticos contendo 5 ml de água deionizada. Registrou-se o nível de fluoreto no período de 04 horas, 24 horas, 03 dias, 07 dias e 14 dias após a confecção, em um analisador Expandable Íon Analyser EA 960, sendo os resultados calculados em &#956;gF/ cm2. Confeccionou-se para o ensaio de TD 120 espécimes para cada CIV, com dimensões de 4 mm de diâmetro por 6 mm de comprimento, divididos aleatoriamente entre os grupos. Realizou-se ensaios mecânicos, com 1 dia e 14 dias após a confecção e estocagem individual dos espécimes em potes plásticos contendo 5 ml de água deionizada, em uma máquina universal de ensaios EMIC DL 500 MF, realizou-se um terceiro teste após 14 dias de ciclos de des-remineralização. Tratou-se estatisticamente os dados obtidos por ANOVA e por Student Newman-Keuls (p<0,05). No teste de LF os resultados demonstraram que o Chemfil liberou uma quantidade significantemente maior de flúor do que o Chemflex. Durante o período do teste a vaselina e o verniz tiveram um comportamento semelhante, mostrando uma menor LF do que o grupo controle nas primeiras 4 horas, com uma maior liberação na análise seguinte (24 horas). Os espécimes protegidos com vaselina e verniz, tiveram uma liberação de flúor semelhante ao grupo controle nos períodos de 3, 7 e 14 dias. O verniz fluoretado mostrou uma forte influência nas primeiras 24 horas. A partir da terceira análise observou-se uma maior liberação de flúor para o Chemfil em comparação com o Chemflex. Em relação ao emprego de um protetor superficial resinoso, encontrou-se tanto para Chemfil quanto para o Chemflex uma redução drástica na liberação de fluoreto, em todos os tempos analisados. No ensaio de TD o Chemfil não mostrou diferença estatisticamente significante quando os resultados de TD do seu grupo controle foram avaliados nos diferentes ensaios (24 horas, 14 dias e des-re), o mesmo acontecendo com o Chemflex. Ao se avaliar a influência dos diferentes protetores de superfície nos CIVs utilizados no presente trabalho observou-se que, para o Chemfil os protetores de superfície tiveram pouca influência no comportamento do material, se comportando na maioria das vezes de forma similar ao grupo controle. Em contrapartida, para o material Chemflex a utilização de um protetor de superfície, como o verniz fluoretado e o adesivo, permitiu maiores valores de resistência à TD. Conclui-se que quando se objetiva o uso do CIV por um curto período o Chemfil sem protetor parece ser o mais indicado, porém se o uso do CIV for por um longo período o Chemflex com a proteção do verniz fluoretado é o mais indicado. / This study evaluated the effect of different protective coatings on the fluoride release (FR) and on the diametral tensile strength (DTS) of two conventional restorative glass ionomer cements (GIC), Chemfil e Chemflex (Dentsply). The cements were manipulated according to the manufacturer's recommendation. The especimens were divided into five groups: group 1 uncoated (control group); group 2 petroleum jelly; group 3 dental varnish (Cavitine, S.S.White); group 4 - fluoride varnish (Duraflur, Denstply); group 5 dentin adhesive (Magic Bond, Vigodent). To the FR test were made 40 especimens to each CIV, with dimensions of 4mm in diameter by 6 mm in length divided randomly into the groups and kept individually in plastic containers with 5 mL of deionized water. The fluoride level was registered within 04 hours, 24 hours, 3 days, 7 days and 14 days after the confection in an Expandable Íon Analyser EA 960, and the results were calculated in &#956;gF/ cm2. To the DTS test 120 especimens were made to each GIC, with dimensions of 4mm in diameter by 6mm in length divided randomly into the groups. Mechanical tests were made within 1 day and 14 days after the confection and saving of specimens individually in plastic containers with 5 mL of deionized water, in an universal tests machine EMIC DL 500 MF, and a third test was made after 14 days of des-remineralization cycles. The data was statistically treated by ANOVA and by Student Newman-Keuls (p<0,05). In the FR test the results showed that the Chemfil released a significant bigger amount of fluoride then the Chemflex. During the tests period, the petroleum jelly and the dental varnish had a similar behavior, presenting lower fluoride release then the control group in the first 4 hours, with a greater release in the second analysis (within 24 hours). The especimens protected by petroleum jelly and dental varnish had a fluoride release similar to the control group on the periods of 3, 7 and 14 days. The fluoride varnish showed a great influence in the first 24 hours. From the third analysis on, each ionomer materials characteristics became prominent, and was noticed a bigger fluoride release on the Chemfil in comparison to the Chemflex. In relation to the coated with dentin adhesive, there was a drastic decrease of fluoride release for Chemfil and Chemflex, in all of the analysis periods. In the DTS test Chemfil didnt show statistically significant difference when the diametral tensile strength of the control group was evaluated in the various periods of time (24 hours, 14 days and de-remineralization), which also happened to Chemflex. When evaluating the influence of different surface protectors on the GIC used at this study, it was noticed that for the Chemfil the surface coating had little influence on the materials behavior, having on most of the time, the same behavior as the control group. However, to the Chemflex material, the use of a surface coating such as the fluoride varnish or the dentin adhesive allowed bigger values of diametral tensile strength. The conclusion is that when the use of GIC is wanted for a short period of time the Chemfil uncoated seems the most indicated. However, if the period of use is longer, the Chemflex with the fluoride varnish protection is the most indicated.
46

Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina / Influence of self-etch adhesive on bond strength of resin-modified glass ionomer to dentin

Giovanna Emann Tavares Menegatti 12 May 2016 (has links)
A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs. / This research aims to evaluate the influence of five dentin pretreatments on microshear bond strength of four resin-modified glass ionomer (RMGI). The experiment was performed in vitro, using 200 bovine incisors. From these, there were obtained 200 dentine fragments that were randomly distributed into 20 groups (n = 10) according to the variation factors comprising five dentin treatment (control group, i.e., no treatment; Polyacrylic Acid 20%; Clearfil SE Bond; Single Bond Universal and Vitremer Primer) and four glass ionomer cements (GC Fuji II LC® CAPSULE; GC Fuji LC LINING® (Paste Pak); Vitrebond® and Vitremer). After preparation of the samples and 24h storage at 37 °C, was performed microshear test in a universal testing machine (Instron 5942 - Canton, MA, USA) with speed of 1mm/min, followed by analysis of the pattern fractures in digital microscope. Statistical analysis of the 400 results was performed by ANOVA nonparametric test for two variation factors (cement and treatment) (p <0.05%) and the post-hoc Tukey (p <0.05%). The tests demonstrated there are statistical difference between treatments, cements and between the interaction of both (p <0.0001). The Clearfil SE (X?=18,26 ± 2,78) and SingleBond (X?=17,28 ± 2,49) promoted the highest bond strength values compared to the other treatments, but showing no statistical difference between them, which represented an increase in bond strength of 121% for Clearfil SE and 109.2% for Single Bond Universal compared to control group. The Polyacrylic Acid (X?=9,94 ± 3,55) has reached intermediate values, corresponding to a 20% increase in adhesive strength compared to control group. This treatment differed significantly from the higher values, but showed no difference compared to Primer Vitremer (X?=8,91 ± 2,97). The control group (X?=8,26 ± 4,17) showed the lowest values, statistically differing from the adhesives and polyacrylic acid, but with results that matched to the treatment with Vitremer Primer. When analyzing the interaction between cement and treatment, all cements tested in this study had higher results when one of the adhesive systems was used as dentin treatment, regardless of which adhesive system. Based on these results, it could be concluded that the two adhesive systems were able to significantly improve the adhesive strength of RMGIs.
47

Avaliação da influência do ultra-som em cimentos de ionômero de vidro na adesão à dentina e nas características dentinárias / Evaluation of ultrasound influence on glass ionomer cement (GIC) regarding its adhesion to dentin and the clinical dentin characteristics

Eduardo Bresciani 23 June 2007 (has links)
Avaliou-se diferentes formas de aplicação do ultra-som (US) sobre a microtração de CIVs (Ketac Molar Aplicap, Ketac Molar Easymix e Fui IX GP) à dentina; e o potencial clínico de restaurações de CIV (Ketac Molar) com US remineralizarem a dentina e seu efeito sobre a flora bacteriana por meio PCR em tempo real, após período de três meses. Na parte laboratorial, foram selecionados 45 terceiros molares extraídos e confeccionadas cavidades para acomodar material, que aleatoriamente recebeu US diretamente (US-D), ou indiretamente (US-I) ou ainda não recebeu (S-US). Os espécimes foram reservados por 1 semana, submetidos ao teste de microtração e os dados analisados por ANOVA 2-critérios. Na parte clínica, 32 pacientes (idade média 13,8) receberam 90 restaurações com CIV, CIV com ultra-som e resina composta, aleatoriamente. A dentina afetada foi avaliada de acordo com a cor, umidade e dureza e uma amostra foi colhida para quantificação de bactérias totais e Lactobacilos. Após três meses, as restaurações foram removidas e nova caracterização clínica e amostragem realizadas. Os dados obtidos foram submetidos aos testes de Friedman e Mann-Witney para os critérios clínicos e ao teste de procedimento de medidas repetidas SAS, para o número de bactérias (p<0,05). Os resultados mostraram que o ultra-som influenciou na adesão dos CIVs, sendo US-D<S-US<US-I. Após três meses de estudo clínico, a dentina apresentouse dura e seca com maior freqüência. A coloração não apresentou mudanças significantes. O número de bactérias totais não foi influenciado pelo tipo de tratamento restaurador. Mais da metade das amostras não mostrou níveis detectáveis de Lactobacilos e nenhuma atividade foi observada. Concluiu-se que o método de aplicação indireta do US deve ser o escolhido. O tipo de tratamento restaurador não influenciou na redução de bactérias residuais, nem na atividade metabólica, embora a dentina apresentasse características clínicas compatíveis com paralisação do processo carioso. / The microtensile bond strength of GICs (Ketac Molar Aplicap, Ketac Molar Easymix and Fuji IX GP), receiving different patterns of ultrasound (US), was evaluated. The clinical potential of GIC (Ketac Molar) restorations with US, in remineralizing dentin and their effects on the microflora were also evaluated. Forty-five extracted third molars were selected for the laboratorial study, and cavities were performed for the GIC filling, which received direct US (D-US), indirect US (I-US) or no US excitation (N-US). After one week, the microtensile test was performed. The obtained data was analyzed using 2-way ANOVA test (P<0.05). Thirty-two patients (mean age of 13.8) were selected for the clinical study and 90 restorations were randomly performed with GIC, GIC plus US or composite resin (CR). The affected dentin was assessed by color, humidity and hardness and a dentin sample was obtained for total bacteria and Lactobacilli quantification, using real time PCR. After 3 months, the restorations were removed and new dentin characterization and sampling performed. Clinical data were analyzed by Friedman and Mann-Whitney tests. Bacterial counts were analyzed by Repeated Measurements Procedure (P<0.05 for all tests). Results showed statistical significant influences of the US on the GIC adhesion to dentin, being D-US<N-US<IUS. After three months of clinical trial, the dentin was scored more frequently as hard and dry. Color was not statistical different in both evaluation periods. The number of total bacteria was not influenced by the type of treatment. Lactobacilli were detected in less than 50% of the samples and presenting no metabolic activity. It was conclude that I-US should be the choice protocol to achieve better adhesion. Although the treated lesions presented clinical characteristics of arrested caries, the type of restoration did not influence the residual bacteria, neither their metabolic activity.
48

Avaliação clínica de dois métodos minimamente invasivos: químico-mecânico e mecânico (ART) / Clinical evaluation of two minimal interventional restorative approaches: chemo-mechanical and mechanical (ART)

Barata, Terezinha de Jesus Esteves 21 September 2007 (has links)
Este estudo comparou o desempenho clínico de dois métodos minimamente invasivos: químico-mecânico [Carisolv®-MediTeam (MQ-M)] e mecânico [Tratamento Restaurador Atraumático (MM-ART)] no tratamento restaurador da cárie dentária. Os métodos foram testados, aleatoriamente, em 50 pares de lesões cariosas similares de dentes permanentes, usando o modelo de estudo \"boca-dividida\", em 50 gestantes (2º trimestre). As variáveis operatórias avaliadas foram: eficácia e eficiência do grau de remoção do tecido cariado, aceitabilidade das voluntárias e percepção dos operadores. Todos os preparos cavitários foram restaurados com cimento de ionômero de vidro de alta viscosidade (Ketac Molar/3M ESPE), usando a técnica restauradora do ART. As restaurações foram avaliadas por dois examinadores calibrados e independentes, seguindo os critérios do ART, após 1 e 4 anos, sendo o nível de concordância interexaminadores de 0,97 e 0,89, respectivamente. Os dados foram submetidos aos testes estatísticos: correlação linear de Pearson, qui-quadrado, \'t\' Student, Fischer, Wilcoxon e intervalo de confiança (IC)95% (p<0,05). Para eficácia, eficiência e aceitabilidade ambos os métodos não apresentaram diferença estatisticamente significante entre si. Em relação à percepção dos operadores foi observada diferença estatisticamente significante a favor do MQ-M. O grau de sucesso das restaurações no grupo do MM-ART foi de 97,6% (IC=87,4-99,9%) após o 1º ano de avaliação e de 84,2% (IC=66,5-92,5%) após o 4º ano. No grupo do MQ-M, 100% (IC=91,8-100%) e 87,2% (IC=72,6-95,7%) das restaurações foram consideradas sucesso no 1º e 4º anos de avaliação, respectivamente. Quanto ao grau de sucesso das restaurações, diferença estatisticamente significante não foi observada entre os métodos após 1 ano (p=0,49) e 4 anos (p=0,75). Conclui-se que ambos os métodos apresentaram boa eficácia, eficiência e aceitabilidade para o tratamento de gestantes. Operadores reportaram maior facilidade técnica no MQ-M do que no MM-ART. Os dois métodos minimamente invasivos não influenciaram no desempenho clínico das restaurações ionoméricas realizadas pela técnica restauradora do ART após 1 e 4 anos. / This study compared the clinical performance of two minimally invasive restorative treatment methods: chemo-mechanical [Carisolv(TM)-MediTeam (CM)] and mechanical [Atraumatic Restorative Treatment (ART)] for managing dental caries. Using a split-mouth design, the methods were tested randomly in 50 matched pairs of permanent teeth. A total of 50 pregnant women (2nd trimester of pregnancy) were treated. The outcome variables were: efficacy and efficiency of caries removal, acceptability and perception of the methods by pregnant women and operators. In both methods, the cavities were restored using the ART approach with high-viscous glass ionomer cement (Ketac Molar/3M ESPE). The restorations were evaluated by 2 calibrated independent examiners according to ART criteria, after 1 and 4 years. The inter examiner kappa was 0.97 and 0.89, respectively. Pearson correlation, 95% Confidence Interval and Student\'s, Chi-square, Fischer\'s and Wilcoxon tests were used for data analysis (p<0.05). The results showed there were no significant differences for efficacy and efficiency of carious dentin removal, as well as for patients\' acceptability, using both methods. A statistically significant difference regarding the feasibility of techniques in favour of the CM method was observed. In the ART method, 97.6% (CI=87.4-99.9%) of the restorations were judged to be successful at 1 year and 84.2% (IC=66.5-92.5%) at 4 years. The 1 and 4-year success for CM method was 100% (CI=91.8-100%) and 87.1% (CI=72.6-95.7%), respectively. The success rate for both methods was not statistically significant after 1 (p=0.49) and 4 (p=0.75) years. It is concluded from the results that both methods showed good efficacy, efficiency and acceptability in treating of the pregnant women. Operator\'s data revealed the CM method as being a more feasible approach than ART. The two minimal intervention restorative approaches showed similar performance after 1 and 4 years in pregnant women.
49

Reparabilidadede um cimento ionomérico aderido ao esmalte com sistemas adesivos autocondicionantes

Guimarães, Murilo de Sousa [UNESP] 16 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-16Bitstream added on 2014-06-13T20:24:35Z : No. of bitstreams: 1 guimaraes_ms_dr_arafo.pdf: 1443329 bytes, checksum: 2d3d8b079af9426aadd16dd726576433 (MD5) / O objetivo deste trabalho, dividido em três estudos, foi investigar (1) a reparabilidade de um cimento de ionômero de vidro modificado por resina, (2) o efeito cariostático e (3) a retenção de selantes ionoméricos aderidos ao esmalte não desgastado com sistemas adesivos autocondicionantes simplificados. Materiais e Métodos: Para o estudo 1 foram confeccionados 60 espécimes de cada material, Vitremer (VT) e resina Z250 (RC). Após envelhecimento químico e térmico, eles foram divididos em 3 grupos de acordo com o tratamento mecânico da superfície: ponta diamantada em alta rotação, ponta em ultra-som e sem desgaste. Cada espécime foi reparado com o mesmo material utilizado inicialmente. Aplicou-se na superfície do VT o Vitremer Primer (VP), e para a resina, utilizou-se ácido fosfórico seguido de adesivo Single Bond. Os espécimes foram isolados deixando exposta a interface de união. Após novo envelhecimento, os mesmos foram impregnados por nitrato de prata, seccionados e avaliados quanto à infiltração e formação de fendas. Os dados foram analisados pelos testes de Kruskal-Wallis e Mann-Whitney (α=0,05). No segundo estudo 64 incisivos bovinos foram distribuídos em 4 grupos segundo o tratamento da superfície de esmalte: VP, Prompt L-Pop (Pr), Xeno III (Xe) ou sem tratamento. Um cilindro de VT foi construído em metade dos dentes, enquanto que a RC foi utilizada na outra metade. Os corpos de prova foram 19 submetidos a desafio cariogênico e seccionados, para realização de testes de dureza em três regiões: externa, união e interna, até a profundidade de 300 μm. Os dados transformados em porcentagem de perda mineral foram analisados pelo teste de ANOVA complementado pelo teste de Tukey ao nível de significância de 5%. No terceiro estudo, 20 pares de molares permanentes hígidos foram selecionados de crianças entre 6 e 10 anos. Em um dos dentes foi aplicado... / The purpose of this work, divided into three studies, was to investigate (1) the reparability of a resin-modified glass-ionomer cement, as well as (2) the cariostatic effect and (3) retention of glass-ionomer sealants bonded to enamel with one-step self-etching adhesive systems. Materials and Methods: For the first study, 60 specimens were prepared with Vitremer (VT) and Z250 resin. After chemical and thermal aging, the specimens were divided into 3 groups according to the mechanical treatment of the surface: diamond bur, ultrasound coupled bur or no treatment. Each specimen was repaired with the original restorative material. For VT repairs, Vitremer Primer (VP) was first applied while for composite resin the surface was phosphoric acid etched followed by the application of Single Bond. The specimens were coated with acid resistant varnish except for 1 mm around de interface. After additional aging, the specimens were impregnated by silver nitrate and sectioned medialy for the evaluation of silver infiltration and gap formation in SEM. Data were submitted to Kruskal-Wallis and Mann-Whitney tests (α=0.05). In the second study, 64 bovine teeth were randomly assigned to 4 groups according to the enamel surface treatment: VP, Prompt L-Pop (Pr), Xeno III (Xe) or no treatment. A cylinder of VT was built up in half of the teeth while a composite resin was used in the other half. The teeth were then submitted to a cariogenic challenge after which they 23 were medialy cut. Transversal hardeness evaluation was performed in three regions, external, interface and internal, up to the depth of 300μm. Hardness numbers were converted to percentage of mineral loss and the data were submitted to ANOVA and Tukey tests at the level of significance of 5%. For the third study, 20 pairs of sound permanent molars were selected from children between 6 and 10 years of age. One tooth of the pair received... (Complete abstract click electronic access below)
50

Reparabilidadede um cimento ionomérico aderido ao esmalte com sistemas adesivos autocondicionantes /

Guimarães, Murilo de Sousa. January 2009 (has links)
Orientador: Josimeri Hebling / Banca: Elisa Aparecida Maria Giro / Banca: Angela Cristina Cilense Zuanon / Banca: Célia Regina Moreira Lanza / Banca: Darlon Martins Lima / Resumo: O objetivo deste trabalho, dividido em três estudos, foi investigar (1) a reparabilidade de um cimento de ionômero de vidro modificado por resina, (2) o efeito cariostático e (3) a retenção de selantes ionoméricos aderidos ao esmalte não desgastado com sistemas adesivos autocondicionantes simplificados. Materiais e Métodos: Para o estudo 1 foram confeccionados 60 espécimes de cada material, Vitremer (VT) e resina Z250 (RC). Após envelhecimento químico e térmico, eles foram divididos em 3 grupos de acordo com o tratamento mecânico da superfície: ponta diamantada em alta rotação, ponta em ultra-som e sem desgaste. Cada espécime foi reparado com o mesmo material utilizado inicialmente. Aplicou-se na superfície do VT o Vitremer Primer (VP), e para a resina, utilizou-se ácido fosfórico seguido de adesivo Single Bond. Os espécimes foram isolados deixando exposta a interface de união. Após novo envelhecimento, os mesmos foram impregnados por nitrato de prata, seccionados e avaliados quanto à infiltração e formação de fendas. Os dados foram analisados pelos testes de Kruskal-Wallis e Mann-Whitney (α=0,05). No segundo estudo 64 incisivos bovinos foram distribuídos em 4 grupos segundo o tratamento da superfície de esmalte: VP, Prompt L-Pop (Pr), Xeno III (Xe) ou sem tratamento. Um cilindro de VT foi construído em metade dos dentes, enquanto que a RC foi utilizada na outra metade. Os corpos de prova foram 19 submetidos a desafio cariogênico e seccionados, para realização de testes de dureza em três regiões: externa, união e interna, até a profundidade de 300 μm. Os dados transformados em porcentagem de perda mineral foram analisados pelo teste de ANOVA complementado pelo teste de Tukey ao nível de significância de 5%. No terceiro estudo, 20 pares de molares permanentes hígidos foram selecionados de crianças entre 6 e 10 anos. Em um dos dentes foi aplicado... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this work, divided into three studies, was to investigate (1) the reparability of a resin-modified glass-ionomer cement, as well as (2) the cariostatic effect and (3) retention of glass-ionomer sealants bonded to enamel with one-step self-etching adhesive systems. Materials and Methods: For the first study, 60 specimens were prepared with Vitremer (VT) and Z250 resin. After chemical and thermal aging, the specimens were divided into 3 groups according to the mechanical treatment of the surface: diamond bur, ultrasound coupled bur or no treatment. Each specimen was repaired with the original restorative material. For VT repairs, Vitremer Primer (VP) was first applied while for composite resin the surface was phosphoric acid etched followed by the application of Single Bond. The specimens were coated with acid resistant varnish except for 1 mm around de interface. After additional aging, the specimens were impregnated by silver nitrate and sectioned medialy for the evaluation of silver infiltration and gap formation in SEM. Data were submitted to Kruskal-Wallis and Mann-Whitney tests (α=0.05). In the second study, 64 bovine teeth were randomly assigned to 4 groups according to the enamel surface treatment: VP, Prompt L-Pop (Pr), Xeno III (Xe) or no treatment. A cylinder of VT was built up in half of the teeth while a composite resin was used in the other half. The teeth were then submitted to a cariogenic challenge after which they 23 were medialy cut. Transversal hardeness evaluation was performed in three regions, external, interface and internal, up to the depth of 300μm. Hardness numbers were converted to percentage of mineral loss and the data were submitted to ANOVA and Tukey tests at the level of significance of 5%. For the third study, 20 pairs of sound permanent molars were selected from children between 6 and 10 years of age. One tooth of the pair received... (Complete abstract click electronic access below) / Doutor

Page generated in 0.1507 seconds