• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 322
  • 46
  • 46
  • 46
  • 45
  • 35
  • 7
  • 7
  • 7
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 327
  • 327
  • 143
  • 131
  • 109
  • 79
  • 58
  • 57
  • 53
  • 40
  • 40
  • 34
  • 30
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Grau de conversão e nanodureza de um cimento resinoso dual fotoativado através de diferentes espessuras de uma resina nanocerâmica CAD/CAM

Chraim, Gustavo Georges de Mattos January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:26:14Z (GMT). No. of bitstreams: 1 341092.pdf: 7453597 bytes, checksum: 8acacedccc72534f3475caa2270543b6 (MD5) Previous issue date: 2016 / Este estudo avaliou o grau de conversão (DC) pela técnica FTIR-ATR e a nanodureza pela técnica de Oliver e Phar de um cimento resinoso de cura dual (RelyX Ultimate, 3M ESPE) fotoativado através de diferentes espessuras da resina nanocerâmica (NCR) LAVA Ultimate (3M ESPE) (0mm, 1mm, 2mm e 5mm), com diferentes tempos de fotoativação (20s e 40s) à uma irradiação constante de 1100mW/cm², imediatamente após a fotoativação e após 24 horas. Os dados coletados foram analisados por uma análise de variância de 3 fatores para medidas repetidas e os efeitos das interações foram analisados pelo teste de Sidak. Para o DC, os resultados mostraram que todos os fatores influenciam significativamente (p<0,001), sendo os maiores graus de conversão são obtidos após 24 horas (p<0,001), com a menor espessura de NCR (p<0,001) e fotoativação por 40s (p<0,001). Também ficou constatada a interação dupla entre todos estes fatores (p<0,001), mas o resultado da interação tripla foi não significativo (p=0,104). Quanto à nanodureza, todos os fatores estudados influenciaram a nanodureza (p<0,001), assim como a interação dupla entre eles (p<0,001) e a interação tripla entre os fatores (p<0,001).<br> / Abstract : This study evaluated the degree of conversion (DC) by FTIR-ATR technique and nanohardness by Oliver and Phar technique of a dual cured resin cement (RelyX Ultimate, 3M ESPE) photoactivated through different thicknesses of nanoceramic resin (NCR) LAVA Ultimate (3M ESPE) (0 mm, 1 mm, 2 mm and 5 mm) with different curing times (20s and 40s) at a constant irradiation 1100mW / cm², immediately after curing and after 24 hours. The collected data was analyzed by 3-way ANOVA repeated measures and the effects of the interactions were analyzed by Sidak test. DC results were significant to all factors (p <0.001), and the highest degrees of conversion are obtained after 24 hours (p <0.001), low thickness NCR (p <0.001) and 40 seconds light cure (p <0.001). It was also found double interaction between all of these factors (p <0.001), but the result of the triple interaction was not significant (p = 0.104). Nanohardness was influenced by all these factors (p <0.001), as well as double interaction between them (p <0.001) and triple interaction between factors (p <0.001).
32

Cimento de silicato : contribuição ao estudo de uma de suas propriedades opticas : reflexão

Stolf, Wolney Luiz, 1937- 18 July 2018 (has links)
Orientador: Luiz Antonio Ruhnke / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-18T00:51:15Z (GMT). No. of bitstreams: 1 Stolf_WolneyLuiz_D.pdf: 4873821 bytes, checksum: 42f912ddfb66772fb04139e3d2c02052 (MD5) Previous issue date: 1967 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Materiais Dentarios / Doutor em Ciências
33

Influência da superfície dentinária bovina na resistência de união de sistemas adesivos /

Lara, Rafael Alves de. January 2014 (has links)
Orientador: Rubens Nisie Tango / Banca: Alessandra Buhler Borges / Banca: Maria Cristina Rosifini Alves-Rezende / Resumo: O objetivo deste estudo foi avaliar o efeito da superfície dentinária bovina na resistência de união (RU) de dois sistemas adesivos. Em dois grupos (n = 5) o esmalte vestibular de incisivos bovinos foi removido até a exposição da camada intermediária de dentina. Nos outros dois grupos os dentes bovinos foram desgastados a partir da face lingual ultrapassando os limites da câmara pulpar expondo dessa forma a parede vestibular da câmara pulpar. Os dentes foram planificados e polidos em lixadeira rotatória com lixas nas granulações sequenciais e crescente de 120 até 600 a fim de padronizar a formação da smear layer. Os adesivos utilizados foram o Single Bond 2 (3M - ESPE) (SB2) e o ClearFill (Kuraray) (CF). Os dentes dos grupos tratados com SB2 e os tratados com CF tiveram um bloco de resina composta (TPH 3, Dentsply) construído sobre cada superfície tratada. Após armazenagem por 24 h em estufa 37 ºC, cada conjunto dente/restauração foi seccionado nos eixos X e Y (ISOMET 1000, Buehler) para obter espécimes em forma de palito, contendo 1 mm² de área de secção transversal. A RU foi obtida em teste de microtração em máquina de ensaio universal (EMIC DL-1000) utilizando-se o dispositivo de Geraldeli, a uma velocidade de 0,5 mm/min. As fraturas foram analisadas em estereomicroscópio e classificadas em duas categorias: Tipo I - fratura adesiva, Tipo II - fratura mista.Os valores de resistência de união (MPa) foram submetidos a análise de variância de 2 fatores e ao teste de Tukey para comparação entre os grupos, ambos com α = 0,05. Foram obtidos os seguintes valores: G1 (normal/convencional) = 43,9 ± 4,8 MPa; G2 (invertido/convencional) = 29,2 ± 5,4 MPa; G3 (normal/autocondicionante) = 13,9 ± 2,1 MPa e G4 (invertido/autocondicionante) = 12,7 ± 3,4 MPa, com significância para direção da dentina,para os sistemas adesivos bem como para a interação dos fatores. Limitado pela metodologia do estudo pode se... / Abstract: The aim of this study was to evaluate the influence of bovine dentin surface on the bond strength (BS) of two adhesive systems. In two groups (n = 5) buccal enamel of bovine incisors was removed by exposing the middle dentin. In the other two groups bovine teeth were ground from the lingual surface exposing the buccal wall of the pulp chamber. The teeth were ground flat and polished on sequentially with # 120 to 600 sandpapers in order to standardize the smear layer. The adhesives were Single Bond 2 (3M - ESPE) (SB2) and ClearFill (Kuraray) (CF). A block of composite resin (TPH 3, Dentsply) was constructed on the adhesive treated surface. After storage for 24 hours at 37 °C, each set was sectioned in X and Y (ISOMET 1000, Buehler) axes to obtain i-shaped specimens, with 1 mm² cross sectional area. The BS was obtained by mechanical microtensile testing in a universal testing (EMIC DL - 1000) using the Geraldeli's device at cross head speed of 0.5 mm/min. The fractures were examined under a stereomicroscope and classified into two categories: Type I - adhesive fracture, type II - mixed fracture. Data of bond strength (MPa) were submitted to 2-way ANOVA and Tukey's test for comparison between groups, both with α = 0.05. With the average values for the groups tested as follows: G1 (normal/Conventional) = 43,9 ± 4,8 MPa, G2 (invert/conventional) = 29,2 ± 5,4 MPa; G3 (normal/self-etching) = 13,9 ± 2,1 MPa and G4 (invert/self-etching) = 12,7 ± 3,4 MPa with significance for the direction of the dentin for adhesive systems as well as for the interaction of factors. Limited by the methodology of the study it can be concluded that the direction of bonding influences on the bond strength primarily in self-etching adhesives / Mestre
34

Influência da aplicação de um adesivo na durabilidade de união entre uma cerâmica feldspática e um cimento resinoso /

Passos, Sheila Pestana. January 2007 (has links)
Orientador: Estevão Tomomitsu Kimpara / Banca: Luciano de Castellucci Barbosa / Banca: Marco Antonio Bottino / Resumo: O objetivo deste trabalho foi avaliar o efeito da aplicacao do adesivo e da ciclagem termica / armazenagem na adesao entre um cimento resinoso, de polimerizacao dual, e uma ceramica feldspatica. As hipoteses sao: (1) a aplicacao do adesivo na ceramica condicionada pode aumentar a resistencia adesiva; (2) a armazenagem e a termociclagem podem diminuir a resistencia adesiva. Vinte blocos (6 x 6 x 4 mm) de ceramica feldspatica microparticulada (Vita VM7) foram confeccionados de acordo com as instrucoes do fabricante. A superficie ceramica foi tratada com acido fluoridrico 10% por 60 segundos, lavada com agua, colocada em agua no ultrassom, seca e silanizada (Porcelain Primer, Bisco). Em seguida, o adesivo foi aplicado em dez blocos (Scotchbond Multi-Purpose Plus Adhesive, 3M ESPE) e fotopolimerizado por 20 segundos. Todos os blocos foram reposicionados em moldes de silicone individuais e o cimento resinoso dual (Variolink base + catalizador, Ivoclar Vivadent) foi aplicado sobre a superficie tratada.Os espécimes foram armazenados em água destilada (37°C) por 24 h e seccionados nos eixos x e y, obtendo-se espécimes com aproximadamente 1 mm'POT.2'de área adesiva. Os 12 corpos de prova (cp)obtidos foram divididos aleatoriamente em 2 condições de armazenamento :seco - ensaio imediato;TC - armazenagem (50 dias) + termociclagem (12.000x, 5°C-55°C). Considerando os 2 fatores do estudo (adesivo e armazenagem), foram constituídos 4 grupos(n=50): Gr1 - sem adesivo + seco; Gr2 - com adesivo + seco; Gr3- sem adesivo + TC; Gr4 - com adesivo + TC. O teste de microtração foi realizado numa máquina de ensaio universal(1 mm/min). A aplicação do adesivo afetou significamente...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study assessed the effect of the adhesive resin application and the aging on the resin cement to feldspathic ceramic. The hypotheses were: (1) the adhesive application on the conditioned ceramic may increase the bond strength; (2) the storage and thermocycling may decrease the bond strength. Twenty blocks (6 x 6 x 4 mm) of feldspathic ceramic (Vita VM7) were produced according to the manufacturer's instructions. One ceramic surface of each block was conditioned with 10% hydrofluoric acid for 60s, washed with water, ultrasonically cleaned into the water, dried, and silanizated (Porcelain Primer, Bisco). Afterwards, only 10 blocks got resin adhesive layer (Scotchbond Multi-Purpose Plus Adhesive, 3M ESPE), which was cured for 20 s. All the blocks were placed in the custom silicone mold and the dual-cured resin cement (Variolink base + catalyst, Ivoclar Vivadent) was applied on the ceramic surface. The specimens were stored in distilled water at 37°C for 24 h and then sectioned in the x and y axis, to produce non-trimmed bar samples with approximately 1 mm'POT.2'of bonding area. The 12 sp obtained from each block were random divided into 2 storage conditions : Dry- microtensile test after cutting; TC -storage (50 days)and thermo-cycling (x12,000, 5°C-55°). Considering the 2 factors of the study (adesive and storage), ...(Complete abstract, click electronic access below) / Mestre
35

Influência de diferentes tratamentos de superfície em uma cerâmica policristalina de zircônia tetragonal (ytzp), na resistência de união com cimento resinoso /

Silva, Alecsandro de Moura. January 2012 (has links)
Orientador: Lafayette Nogueira Júnior / Coorientador: Marcos Massi / Banca: Eduardo Shigueyuki Uemura / Banca: Rubens Guimarães Filho / Resumo: Este estudo avaliou, in vitro, a influência de diferentes tratamentos de superfície na resistência de união ao cisalhamento entre uma cerâmica de zircônia tetragonal policristalina estabilizada com ítria (Y-TZP) e um cimento resinoso. Amostras com tamanho mínimo de (1,5 X 1,5cm) uma cerâmica de Y-TZP foram confeccionados e sintetizados, de acordo com as recomendações do fabricante, e limpos sonicamente em água destilada por 10 min. De acordo com os fatores "tratamento de superfície" e "presença de filme à base de Si", os blocos foram aleatoriamente divididos em 6 grupos: G1) polido; G2) polido revestido com filme; G3) jateamento com partículas (110μm) de alumina revestida por sílica; G4) jateamento com partículas (110 μm) de alumina revestida por sílica revestido com filme; G5) jateamento com partículas (100μm) de alumina; G6) jateamento com partículas de alumina. Os filmes foram crescidos sobre a superfície cerâmica pelo método químico de deposição a plasma utilizando o hexamethylsiloxano em forma de vapor. Cilíndros (cilíndros Ø: 2,4 mm; 4 mm altura) de um cimento resinoso (Rely X U100/3M ESPE) foram confeccionados sobre a superfície da cerâmica após o tratamento de superfície (n=10). As amostras foram submetidas ao ensaio de resistência ao cisalhamento em máquina de ensaio Universal (EMIC) a velocidade de 1 mm/min. utilizando célula de carga de 50Kgf. Os dados obtidos foram submetidos ao teste ANOVA dois fatores e ao teste Tukey com variância aceitável de 0,05%. Resultados: O estudo revelou que o filme interferiu negativamente nos resultados de resistência adesiva para a superfície jateada com óxido de alumínio e não interferiu nos resultados dos demais tratamentos de superfície Conclusão: O tratamento de superfície, com filme de plasma contendo hexamethilsiloxano em forma de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This in vitro study evaluated the influence of different surface treatments on shear bond strength between a polycrystalline ceramic tetragonal zirconia stabilized with yttria (Y-TZP) and a resin cement. Minimum number of blocks (1.5 X 1.5 cm) of a ceramic Y-TZP were prepared and synthesized according to the manufacturer's recommendations, and sonically cleaned in distilled water for 10 min. According to the factors "surface treatment" and "presence of Si-based film", the blocks were randomly divided into six groups: G1) polished; G2) polished film-coated, G3) blasting particles (110μm) of alumina coated silica; G4) blasting particles (110 mM) of alumina-coated silica-coated film; G5) blasting particles (100μm) of alumina and G6) sandblasting with alumina particles. The films were grown on the ceramic surface by chemical method using plasma deposition hexamethylsiloxane in vapor form. Cylinders (2.4 mm x Ø 4 mm thick) of a cement (ESPE U100/3M Rely X) were prepared on the ceramic surface after the surface treatment (n = 10). The samples were submitted to shear bond strength in an universal testing machine (EMIC) at a speed of 1 mm / min. using a 50kgf load cell. The data were subjected to two-factor ANOVA and Tukey test with acceptable variance of 0.05%. Results: The study revealed that the film had a negative influence on bond strength to the surface blasted with aluminum oxide and did not interfere with the results of other surface treatments. Conclusion: The surface treatment with plasma containing hexamethylsiloxane film in vapor form (HMDSO) did not produce better bond strength values by the method of shear type knife when compared to gold standard system blasting Rocatec (3M/ESPE). The thermal cycling... (Complete abstract click electronic access below) / Mestre
36

Avaliação da biocompatibilidade de quatro agentes para cimentação através do estudo das reações teciduais em conjuntivo da ratos /

Nogueira Junior, Lafayette. January 2001 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Eduardo Piza Pellizi / Banca: Humberto Gennari Filho / Banca: Marcos Yasunóri Maekawa / Banca: Clovis Pagani / Resumo: A biocompatibilidade de quatro agentes para cimentação de peças protéticas foi avaliada por meio de implantes em tecido conjuntivo subcutâneo de ratos. Neste trabalho foram avaliados um cimento de fosfato de zinco (Lee Smith - Vigodent), um cimento de ionômero de vidro (Ketac-Cem - ESPE) e dois cimentos resinosos (Panavia Ex 21 - Kuraray Co.; Enforce- Dentsply). Após a manipulação dos cimentos, os implantes foram realizados, utilizando-se tubos de polietileno preenchidos com os agentes cimentantes e inseridos em lojas cirúrgicas preparadas no dorso dos animais, os quais foram sacrificados nos períodos de observação de 14, 30, 60 e 84 dias. Os tecidos circunjacentes aos implantes foram removidos, incluídos em parafina e corados com hematoxilina e eosina para análise em microscopia óptica. Os resultados mostraram que todos os agentes de cimentação causaram uma resposta tecidual nos períodos avaliados; o cimento de fosfato de zinco apresentou um menor grau de reação tecidual nos períodos de 14, 30 e 60 dias; o cimento de ionômero de vidro apresentou as piores características de biocompatibilidade quando em contata com o tecido conjuntivo de ratos / Abstract: The biocompatibility of four luting agents was evaluated in rats subcutaneous connective tissue implants. Polyethylene lubes filled with the luting agents were surgically implanted into the dorsal subcutaneous tissue of rats. The tube was left implanted for periods of 14, 30, 60 and 84 days, following wich the animals were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microspic . The results showed that all the luting caused an tissue answer in the appraised periods; the phosphate of zinc cement presented a smaller degree of tissue reaction in the periods of 14, 30 and days; the of glass ionomer cement presented the worst characteristics of biocompatibility when in contact with the conjunctive tissue in rats / Doutor
37

Avaliação da microinfiltração marginal em restaurações de resina composta, quando o colágeno dentinário é mantido ou eliminado após o condicionamento ácido, alterando-se o período de armazenamento e a termociclagem /

Torres, Carlos Rocha Gomes. January 2002 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Luiz André Freire Pimenta / Banca: Michel Nicolau Youssef / Banca: Rebeca Di Nicoló / Banca: Regina Celia Santos Pinto Silva / Resumo: Resumo: O objetivo deste estudo foi avaliar o grau de microinfiltração marginal em restaurações de resina composta, diante das variáveis remoção ou não do colágeno dentinário após o condicionamento ácido, e utilização ou não de uma camada de resina composta fluida sobre a dentina desproteinizada, alterando-se os seguintes fatores: a)tempo de armazenagem (0, 6 e 12 meses): b) ciclagem térmica (500, 1.500 e 2.500 ciclos). Para tal, 180 dentes bovinos receberam preparos classe V ao nível da junção amelocementária. Eles foram divididos em três grupos: grupo C - foi aplicado o sistema adesivo Single Bond (3M), segundo as recomendações do fabricante, e a seguir procedida a restauração com a resina composta Z250 (3M); grupo H - após o condicionamento ácido foi aplicada uma solução aquosa de NaOCI a 10% por 1 min, e então aplicado o adesivo Single Bond e a resina composta Z250; grupo HF- semelhante ao grupo H, exceto que após a polimerização do adesivo, uma fina camada de resina composta fluída Natural Flow (DFL) foi aplicada e polimerizada, antes da inserção da resina Z250. Todos os espécimes sofreram 500 ciclos ténnicos (5 ±5°C a 55 ±5°C). Os espécimes em cada grupo foram divididos ao acaso em três subgrupos. No primeiro, a microinfiltração marginal foi avaliada após 24h. No segundo, os espécimes permaneceram imersos em água destilada contendo 0,4% de azida sódica em estufa a 37°C por seis meses, sendo que após este período sofreram mais 1.000 ciclos térmicos. No terceiro, os espécimes permaneceram imersos por 12 meses, e receberam mais 1.000 ciclos térmicos a cada 6 meses, totalizando 2.500 ciclos. Após os respectivos períodos de armazenagem, a microinfiltração marginal foi avaliada pelo método do nitrato de prata seguido pela diafanização. Os espécimes foram analisados em estereomicroscópio e receberam escores de 0 a 4. Os dados... / Abstract: The aim of this study was to evaluate the marginal microleakage in composite resin restorations. under the variables removal or not of the dentin collagen after the acid conditioning, and utilization or not of a flowable composite resin layer on deproteinized dentin, changing the factors: a) storage time (0, 6 and 12 months); b) thermal cycling (500, 1.500 and 2.500 cycles). For this, 180 bovine teeth received class V cavit preparation at cementun-enamel junction. They were assigned to three groups: group C - was applied the Single Bond adhesive system (3M), according to manufacturer instructions, and restored with Z250 composite resin (3M); group H - after the acid conditioning was applied a 10% NaOCI aqueous solution for 1min, and then applied the adhesive and restored with Z250; group HF - like the group H, except that after the adhesive polymerization. a thin layer of a flowable composite resin Natural Flow (DFL) was applied and polimerized, before the placement of Z250. AIl specimens received 500 thermal cycles (5±5'C to 55±5-'C). The specimens in each group were randomly assigned to three subgroups. In the first, the microleakage was evaluated after 24h. In second, the specimens were stored in distillate water containing 0,4% of sodium azide in stove at 37'C, for 6 months, and after this time received more 1.000 thermal cycles. In the third, the specimens were stored for 12 months, and they received more 1.000 thermal cycles for each 6 months. At the end of each storage time, the microleakage was evaluated by the silver nitrate method, followed by cleaning technique. The specimens were analyzed in stereomicroscope and received scores of 0 to 4. The data were submitted to statistical analysis, using the Kruskal Wallis's and Multiple Comparisons tests. After 6 months of storage, the groups H and HF showed falls in microleakage, while the group C didn't showed significant differences / Doutor
38

Influência e caracterização dos efeitos do 10-MDP na adesâo zircônia e cálcio / Influence and characterization of 10-MDP effects on zirconia and calcium adhesion

Paula, Diego Martins de 03 February 2017 (has links)
PAULA, D. M. Influência e caracterização dos efeitos do 10-MDP na adesâo zircônia e cálcio. 2017. 52 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2017. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-02-24T13:54:58Z No. of bitstreams: 1 2017_dis_dmpaula.pdf: 1263587 bytes, checksum: 5b65695a4c5007d12a2b14b88f45e408 (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-02-24T13:55:05Z (GMT) No. of bitstreams: 1 2017_dis_dmpaula.pdf: 1263587 bytes, checksum: 5b65695a4c5007d12a2b14b88f45e408 (MD5) / Made available in DSpace on 2017-02-24T13:55:05Z (GMT). No. of bitstreams: 1 2017_dis_dmpaula.pdf: 1263587 bytes, checksum: 5b65695a4c5007d12a2b14b88f45e408 (MD5) Previous issue date: 2017-02-03 / The replacement of metallic infrastructure by dental ceramics brings good aesthetics and greater biocompatibility of fixed prostheses. The material of choice is zirconia (ZrO2) because of its excellent mechanicals properties. Conventional cementing techniques are not effective for this type of infrastructure, and 10-methacryloyloxy-decyl-dihydrogenphosphate (10-MDP) should be used as a bonding agent. The present study aims to characterize 10-MDP with zirconia using micro-Raman spectroscopy. For this, (1) micro-Raman spectroscopy was used to find the vibrational peak of ZrO2 binding with 10-MDP and calcium, not yet demonstrated in the literature. (2) The micro-shear bond strength of the dual resin zirconia cement with the presence of 10-MDP in the composition of the primer and the self-adhesive resin cement. (3) If the presence of 10-MDP without ceramic primer changes the degree of conversion of the conventional dual resin cement to a zirconia. In this study the 1545cm-1 and 1562cm-1 peaks were found to refer to zirconia binding with 10-MDP and the 3391cm-1 and 3442cm-1 peaks relative to the 10-MDP calcium binding. The presence of 10-MDP in both the ceramic primer and the self-adhesive resin cement improved a micro-shear bond strength of the resin cement. The high concentration of 10-MDP was not buffered by ZrO2 and reduced the degree of conversion of the resin cement to the experimental primers, but not with the low concentration of 10-MDP. We can conclude that the non-destructive method of micro-Raman spectroscopy was able to characterize a chemical union of 10-MDP with a zirconia, and that such monomer should be used in low concentrations in primers for zirconia to avoid reducing the polymerization of the cement residue. / A substituição da infraestrutura metálica pela cerâmica odontológica traz boa estética e maior biocompatibilidade às próteses fixas. Suas excelentes propriedades mecânicas têm levado a zircônia (ZrO2) ser o material de escolha. Técnicas convencionais de cimentação não se mostram efetivas para esse tipo de infraestrutura, devendo-se lançar mão do 10-MDP (10-metacriloiloxi-decil-di-hidrogenofosfato) como constituinte do agente de união. O presente estudo tem o objetivo de caracterizar união do 10-MDP com a zircônia e com o cálcio utilizando a espectroscopia micro-Raman. Para isso, foi utilizado a (1) espectroscopia micro-Raman para encontrar o pico vibracional das ligações do ZrO2 com o 10-MDP e cálcio, ainda não demonstrado na literatura. (2) A resistência de união ao micro-cisalhamento do cimento resinoso dual à zircônia com a presença do 10-MDP na composição do primer cerâmico e do cimento resinoso autoadesivo. (3) Se a presença do 10-MDP no primer cerâmico altera o grau de conversão do cimento resinoso dual convencional sobre a zircônia. Nesse estudo foi descoberto os picos 1545cm-1 e 1562cm-1 referentes a ligação da zircônia com o 10-MDP e os picos 3391cm-1 e 3442cm-1 referentes a ligação do 10-MDP ao cálcio. A presença do 10-MDP tanto no primer cerâmico como no cimento resinoso autoadesivo melhoraram a resistência de união ao micro-cisalhamento do cimento resinoso. A concentração de 40% do 10-MDP não foi tamponada pelo ZrO2 e reduziu o grau de conversão do cimento resinoso com os primers experimentais, mas não com o comercial contendo menor concentração de 10-MDP. Podemos concluir que método não destrutivo da espectroscopia micro-Raman foi capaz de caracterizar a união química do 10-MDP com a zircônia, e que tal monômero deve ser usado em baixa concentração em primers para zircônia para evitar reduzir a polimerização do cimento resinoso.
39

Desenvolvimento e avaliação de um novo adesivo odontológico para remineralização biomimética de interfaces adesivas / Development and evaluation of a new dental adhesive for biomimetic remineralization of adhesive interfaces

Moura, Maria Elisa Martins 16 February 2017 (has links)
MOURA, MA E. M. Desenvolvimento e avaliação de um novo adesivo odontológico para remineralização biomimética de interfaces adesivas. 2017. 52 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2017. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-03-31T12:44:20Z No. of bitstreams: 1 2017_dis_memmoura.pdf: 1610795 bytes, checksum: 7b94000a4c370241e6010bdbc2ddf84f (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-03-31T12:44:27Z (GMT) No. of bitstreams: 1 2017_dis_memmoura.pdf: 1610795 bytes, checksum: 7b94000a4c370241e6010bdbc2ddf84f (MD5) / Made available in DSpace on 2017-03-31T12:44:27Z (GMT). No. of bitstreams: 1 2017_dis_memmoura.pdf: 1610795 bytes, checksum: 7b94000a4c370241e6010bdbc2ddf84f (MD5) Previous issue date: 2017-02-16 / A recent alternative to promote restorative durability is biomimetic remineralization. It uses two phosphoprotein analogs from dentinogenesis and could be performed using a two-step self-etching adhesive containing bioactive calcium phosphates in the adhesive and a new biomimetic analogue (EDTF, ethylene diamine tetramethylene phosphonate) in the primer, acting as the two different types of analogues Already known. Thus, an experimental adhesive was prepared and pre-mixed with mono-calcium phosphate monohydrate and beta-phosphate tri-calcium in the bond. In addition, primers were developed according to the experimental design. A primer with no analogs and no particles in the bond (one negative control, CN), one containing the most used analogues in the literature trimetaphosphate (TMP) of sodium and polyacrylic acid (APA) (TMP / APA - positive control, CP), and others containing EDTF / TMP, EDTF / APA or EDTF alone were prepared. A group with only particles in the bond and without the analogs in the primer was also used. These adhesive systems were applied in artificially simulated carious dentin (DAC) and in healthy dentin of extracted human molars. After periods of 24h and 6 months of storage, they were evaluated by microtraining, nanoinfiltration and Micro-Raman spectroscopy of the interface (hybrid layer) and the underlying dentin. Microtraction data were analyzed statistically with two-way ANOVA and Tukey's test (α = 5%). In the microtraction of the hybrids, there was only statistical difference (p <0.05) in the EDTF / TMP groups, showing an increase in union strength after 6 months and in the EDTF / APA group, which had a decline. In DAC, there was a decrease in CN, EDTF / TMP and EDTF / APA groups (p <0.05). In the analysis of nanoinfiltration in DAC, the CN revealed the presence of cracks and degradation in the immediate dentin region, and in the adhesive layer after aging, which was not observed in the other groups. In Micro-Raman spectroscopy it was possible to observe the presence of more marked mineralization in the CP, EDTF, EDTF / TMP and only particles groups, but this was not observed in the CN and EDTF / APA groups. It is concluded that the best results for adhesion and remineralization of dentin affected by caries are obtained with the use of traditional analogues (TMP / APA) or with EDTF alone and associated with TMP, without affecting the adhesion to the healthy dentin. / Uma recente alternativa para promover uma maior durabilidade às restaurações é a remineralização biomimética. Ela utiliza dois análogos de fosfoproteínas da dentinogênese e poderia ser realizada utilizando um adesivo autocondicionante de dois passos contendo fosfatos de cálcio bioativos no adesivo e um novo análogo biomimético (EDTF, etilenodiamino tetrametileno-fosfonato) no primer, agindo como os dois diferentes tipos de análogos já conhecidos. Assim, um adesivo experimental foi preparado e aplicado com mistura prévia com fosfato de mono-cálcio mono-hidratado e beta fosfato tri-cálcio no bond. Além disso, foram desenvolvidos primers de acordo com o delineamento experimental. Um primer sem análogos e sem partículas no bond (controle negativo, CN), um contendo os análogos mais utilizados na literatura trimetafosfato (TMP) de sódio e ácido poliacrílico (APA) (TMP/APA - controle positivo, CP), e outros contendo EDTF/TMP, EDTF/APA ou somente EDTF foram preparados. Um grupo somente com partículas no bond e sem os análogos no primer também foi usado. Estes sistemas adesivos foram aplicados em dentina afetada por cárie (DAC) simulada artificialmente e em dentina hígida de molares humanos extraídos. Após períodos de 24h e 6 meses de armazenamento, eles foram avaliados por teste de microtração, nanoinfiltração e espectroscopia Micro-Raman da interface (camada híbrida) e da dentina subjacente. Os dados de microtração foram analisados estatisticamente com ANOVA dois fatores e Teste de Tukey (α=5%). Na microtração dos hígidos só houve diferença estatística (p<0,05) nos grupos EDTF/TMP apresentando um aumento na resistência de união após 6 meses e no grupo EDTF/APA que teve um declínio. Em DAC, houve uma queda nos grupos CN, EDTF/TMP e EDTF/APA (p<0,05). Na análise de nanoinfiltração em DAC, o CN revelou a presença de fendas e degradação na região de dentina subjacente de forma imediata, e na camada de adesivo após o envelhecimento, o que não foi observado nos demais grupos. Na espectroscopia Micro-Raman foi possível observar a presença de mineralização mais acentuada nos grupos CP, EDTF, EDTF/TMP e somente partículas, porém isso não foi observado nos grupos CN e EDTF/APA. Conclui-se que os melhores resultados para a adesão e a remineralização da dentina afetada por cárie são obtidos com o uso dos análogos tradicionais (TMP/APA) ou com EDTF sozinho e associado ao TMP, não afetando a adesão à dentina hígida.
40

Comportamento de implantes de cimento portland em fase sólida : análise dimensional e histomorfométrica / Fernando Luiz Zanferrari ; orientador, Wilson Denis Martins

Zanferrari, Fernando Luiz January 2011 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Bibliografia: f. 69-73 / Objetivos: O objetivo deste trabalho foram avaliar a estabilidade dimensional do cimento Portland branco quanto ao seu volume e área superficial, mensurar a quantidade de tecido ósseo neoformado por meio de histomorfometria após implantação subperióstea d / Objectives: The aim of this study was to evaluate the dimensional stability of white Portland cement as its volume and surface area, measure the amount of new bone by histomorphometry after subperiosteal implantation of samples of Portland cement in the f

Page generated in 0.096 seconds