• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 231
  • 10
  • 10
  • 10
  • 10
  • 10
  • 1
  • Tagged with
  • 233
  • 233
  • 166
  • 92
  • 89
  • 88
  • 76
  • 76
  • 65
  • 50
  • 48
  • 37
  • 36
  • 35
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação in vitro da microdureza superficial do esmalte bovino exposto a soluções ácidas, após receber ou não, clareamento com peróxido de hidrogênio a 35%

Zanet, Caio Gorgulho [UNESP] 09 April 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-04-09Bitstream added on 2014-06-13T20:22:07Z : No. of bitstreams: 1 zanet_cg_dr_sjc.pdf: 1385810 bytes, checksum: 116232ec5fb14d4d25cddd152219e177 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Erosão é a perda superficial do esmalte dentário causada por processos químicos que não envolvem bactérias. Alguns fatores intrínsecos e extrínsecos como a presença de substâncias ácidas na cavidade bucal, promovem uma redução do pH do meio, aumentando a erosão ácida. Assim, o objetivo deste estudo foi avaliar a microdureza do esmalte de dentes bovinos clareados e não clareados com peróxido de hidrogênio a 35 %, após a ação de: refrigerante a base de cola, suco artificial em pó contendo citrato de sódio e ácido clorídrico. Os corpos de prova foram divididos em dois grupos, onde 45 amostras de um dos grupos receberam a ação do agente clareador uma vez por semana durante duas semanas. Após este período, as amostras de cada grupo inicial foi dividido em 3 grupos com 15 amostras cada, as quais foram imersas nas soluções ácidas diariamente por 5 minutos e permanecendo 23 horas e 55 minutos em saliva artificial. O experimento foi realizado por 21 dias e as leituras de microdureza de cada corpo de prova foi realizada semanalmente. Os dados obtidos segundo as variáveis: tempo, substância ácida e condição do substrato (esmalte clareado ou não) foram submetidos aos testes estatísticos: Anova e Tukey. Concluiuse que todas as soluções ácidas testadas interferiram com a microdureza do esmalte. Dentes clareados foram os mais susceptíveis aos efeitos erosivos das soluções ácidas. O ácido clorídrico causou o maior dano ao esmalte dentário e o tempo de exposição do esmalte às soluções ácidas influiu diretamente na quantidade de desmineralização. / Acid erosion is the loss of enamel surface caused by chemical processes that do not involve bacteria. Some intrinsic and extrinsic factors, as the presence of acid substances in the oral cavity, promote a pH reduction, increasing acid erosion. Thus, the aim of this study was to evaluate the microhardness of bleaching and not bleaching bovine enamel after the effect of a cola drink, an artificial powder juice and hydrochloric acid. The data obtained by the variables: time, acid solution and condition of substrate (enamel whitening or not whitening) were subjected to statistical tests: ANOVA and Tukey. It was concluded that all acid solutions tested interfered with the enamel microhardness. Hydrochloric acid caused the biggest damage to enamel and the time of enamel exposure to acid solutions directly influenced the demineralization amount. Whitened enamel was more affected by acid erosion. -
52

Influência de diferentes procedimentos restauradores na resistência á fratura de dentes com cavidade classe IV submetidos ao clareamento dental interno

Roberto, Andiara Ribeiro [UNESP] 30 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-30Bitstream added on 2014-06-13T20:41:42Z : No. of bitstreams: 1 roberto_ar_dr_arafo.pdf: 452023 bytes, checksum: 43fcf27450c655f9ab84cfbe7a78de11 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve o objetivo de investigar a influência de diferentes procedimentos restauradores diretos com resina composta e pinos de fibra de vidro, na resistência à fratura de dentes com cavidades Classe IV, tratados endodonticamente e submetidos ao clareamento interno. Quarenta (n=40) incisivos laterais superiores humanos hígidos foram utilizados. Todos os dentes, com exceção do Grupo controle, foram submetidos ao tratamento endodôntico e então divididos em 5 Grupos (n=8): GI: Dentes hígidos; GII: Dentes tratados endodonticamente + resina composta (RC); GIII: Dentes tratados endodonticamente + clareamento com peróxido de hidrogênio (PH) a 35% + RC; GIV: Dentes tratados endodonticamente + Clareamento com PH a 35% + pino de fibra de vidro (Everstick/StichTeck) + RC; GV: Dentes tratados endodonticamente + Clareamento PH a 35% + RC e pino de fibra de vidro (Fibrekor Post; Jeneric Pentron Inc., Wallingford, CT, USA);. Os dentes tratados endodônticamente receberam cortes na coroa simulando uma classe IV e posteriormente restaurações de resina composta. O sistema LED-LASER Whitening Lase Light Plus (DMC Equipamentos Ltda, São Carlos, SP, Brasil) foi utilizado para ativação do agente clareador. Após o processo de clareamento, a restauração provisória e o tampão cervical dos dentes submetidos ao clareamento foram removidos para que cada Grupo fosse submetido ao procedimento restaurador. Após a confecção das restaurações as mesmas foram submetidas ao teste de resistência a fratura, em máquina de ensaios (EMIC). A Análise de Variância apontou efeito significativo de Grupos sobre a resistência (p=0,041). O teste de Tukey foi aplicado nas comparações múltiplas das médias de resistência, identificando somente a média de GIII (dentes tratados endodonticamente +clareamento com PH... / This study aimed to investigate the influence of restorative procedures on fracture resistance of teeth with Class IV cavities endodontically treated and submitted to internal bleaching with light source acceleration using LED-LASER system. Forty (n = 40) lateral incisors and healthy humans were used. All teeth, except for the control Group, were submitted to endodontic treatment and then divided into 5 Groups (n = 8): GI: healthy teeth, GII: endodontically treated teeth + composite, GIII: Teeth whitening endodontically treated with PH 35% + composite, GIV: Teeth whitening endodontically treated with PH 35% glass fiber post (Everstick / StichTeck) + composite, GV: Teeth whitening endodontically treated PH 35% + composite fiber and glass post (Fibrekor Post; Jeneric Pentron Inc., Wallingford, CT, USA). The crow of endodontically treated tooth was cut simulating a Class IV. The system LED LASER-Light Plus Whitening Lase (DMC Equipment Ltda, São Carlos, SP, Brazil) was used to activate the bleaching agent. After the whitening process, the buffer cervical and the temporary restoration of teeth submitted to bleaching have been removed so that each Group was subjected to the restorative procedure. After restorations the specimens were subjected to the same fracture toughness test, in a testing machine (EMIC). Analysis of Variance (ANOVA) showed significant effect on the resistance Group (p = 0.041). The Tukey test was applied in multiple comparisons for resistance means values, identifying only the mean of GIII (endodontically treated teeth bleaching with PH 35% + composite) significantly lower than GI (healthy teeth) (p = .026). It was concluded that teeth endodonticamentes treated with cavity class IV, subjected to internal dental bleaching with PH 35% and only restored with RC, have lower fracture toughness when compared to... (Complete abstract click electronic access below)
53

Avaliação in vitro da eficácia da fotoativação no clareamento dental utilizando a técnica em consultório

Araújo, Rodrigo Maximo de [UNESP] 12 June 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-06-12Bitstream added on 2014-06-13T21:05:37Z : No. of bitstreams: 1 araujo_rm_dr_sjc.pdf: 355643 bytes, checksum: bf7137e386ce1c8e17589f337e9e1a65 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar se fontes de luz aumentam a eficácia do peróxido de hidrogênio na técnica de clareamento profissional. Para tal, 60 dentes incisivos bovinos foram extraídos e limpos com lâminas de bisturi. As dimensões coronárias e radiculares foram padronizadas a partir do limite amelo-cementário, procedendo-se os devidos cortes perpendiculares na região incisal e apical. A porção lingual foi removida por corte longitudinal, recebendo a superfície vestibular uma profilaxia com jato de bicarbonato de sódio, sendo a porção dentinária exposta, condicionada com H3PO4 a 38% por 15s. Os corpos-de-prova foram levados a um banho de água em ultra-som por 20 min e a seguir imersos em solução de café solúvel a 25%, por duas semanas. A seguir, a porção dentinária foi impermeabilizada com esmalte para unhas incolor e a face vestibular polida com pasta de óxido de alumínio e disco de feltro. Os corpo-de-prova foram divididos aleatoriamente em 5 grupos, sendo a cor inicial mensurada através do espectrofotômetro-EasyShade (VITA-Zahnfabrik, Bad Sackingen, Alemanha ). Todos os corpos-de-prova receberam três aplicações por 15 min do gel clareador Opalescence Xtra-Boost (Ultradent South Jordan, UT, USA). O grupo 1 não recebeu fotoativação, sendo considerado controle, grupo 2 foi ativado com um fotopolimerizador de luz halôgena, grupo 3 ativado com aparelho híbrido de LED azul /LASER, grupo 4 ativado com aparelho de LED verde /LASER e grupo 5 ativação com LED vermelho. Após o clareamento foi novamente mensurada a cor. Os dados de variação de cor ΔE, Δa*, Δb*e ΔL* e os referentes a escala de cor Vita Clássico, foram submetidos a análise de variância e teste de Tukey e Dunn ( p = 5%). Concluimos que: o desempenho do peróxido de hidrogênio a 38 %, teve seu efeito intensificado conforme a fonte de luz utilizada;a diferença... / The aim of this in vitro study was to evaluate of the Light Activations of in office bleaching agent technique increase the effectiveness of the procedure, measured by the change of teeth’s color. In this study, 60 bovine incisor teeth were extracted, specimen’s size was standardized and dentin portion was exposed by carburundum disks. All the surfaces received a sodium bicarbonate prophylaxis and then conditioned by 38% phosphoric acid during 15s. The samples were then brought to a water bath in ultrasound for 20 min and immersed in a 25% soluble coffee solution for two weeks period. Then, the portion dentin was polished with felt’s disk and aluminium oxide paste, and finally sealed with colorless ink nail. The specimens were randomly divided into 5 groups, and the original color measured by spectrophotometer - EasyShade (VITA-Zahnfabrik, Bad Sackingen, Germany). All specimens received three applications of bleaching agent Opalescence Xtra-Boost (Ultradent South Jordan, UT, USA) during a period of 15 min each. Group 1 did not receive light activation and was considered as a Control Group, Group 2 was activated with a Halogen light (15 min), Group 3 was activated with hybrid of blue LED / Laser (15 min), Group 4 was activate with green LED / Laser (15min) and Group 5 activated with red Laser (15 min). The color was measured again after bleaching in all specimens. The data of changing color variation ΔE, Δa*, Δb* and ΔL* and those references on Vita Classic, were subjected to ANOVA, Tukey's test and Dunn (p = 5%). The performance of hydrogen peroxide 38% was affected by the source of light used. Significantly differences in reduction of color were observed with all light activators employed and particularly with the blue LED light and Halogen. Quantitative... (Complete abstract click electronic access below)
54

Efeito citotóxico trans-amelodentinário de um gel clareador com 35% de peróxido de hidrogênio aplicado sobre dentes restaurados ou não com resina composta

Sacono, Nancy Tomoko [UNESP] 10 January 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-01-10Bitstream added on 2014-06-13T19:43:58Z : No. of bitstreams: 1 sacono_nt_dr_arafo.pdf: 695189 bytes, checksum: 66481f0fa19f637e17a35d32612d52da (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi avaliar a citotoxicidade trans-amelodentinária de um gel clareador com 35% de H2O2 aplicado sobre dentes com ou sem restauração de resina composta e submetidos ou não a procedimento de envelhecimento. Cavidades preparadas em discos de esmalte/dentina obtidos de dentes bovinos íntegros foram restauradas com sistema adesivo autocondicionante e resina composta. Os discos foram armazenados em solução aquosa por 24 horas ou 6 meses e o procedimento de termociclagem foi realizado somente nos grupos armazenados por 6 meses. Os discos foram posicionados em câmaras pulpares artificiais e distribuídos em grupos: Íntegros 24 horas; Íntegros 24 horas clareados; Íntegros 6 meses; Íntegros 6 meses clareados; Restaurados 24 horas; Restaurados 24 horas clareados; Restaurados 6 meses; e Restaurados 6 meses clareados. O gel clareador foi aplicado sobre os discos por 15 minutos (1 aplicação) ou por 45 minutos (3 aplicações consecutivas de 15 minutos cada), sendo que os extratos (meio de cultura em contato com a dentina + componentes dos gel clareador que se difundiram através dos discos) foram recolhidos e aplicados por 1 hora sobre células odontoblastóides MDPC-23 em cultura (12.500 células/cm2). Para o experimento no qual o gel clareador foi aplicado somente uma vez, observouse redução significativa do metabolismo celular apenas para o grupo de dentes restaurados quando comparado ao controle (íntegros 24 horas não clareados) e ao grupo restaurado não clareado, independente do tempo de armazenamento (Tukey, p<0,05). Quando o gel clareador foi aplicado por três vezes consecutivas, houve diminuição do metabolismo celular estatisticamente significante em todos os grupos clareados (Mann-Whitney, p<0,05), sendo observadas intensas alterações morfológicas das células MDPC-23. Entretanto, não houve diferença com relação a presença de restauração e o tempo... / The aim of this in vitro study was to evaluate the trans-enamel and transdentinal cytotoxic effects of a 35% hydrogen peroxide (H2O2) bleaching gel applied on non-restored or restored teeth, submitted or not to aging by water storage and thermocycling. Enamel/dentin discs were obtained from bovine central incisors and restored or not with self-etching adhesive system and composite resin. These discs were storage in water for 24 hours or 6 months (aging). Thus, the discs were adapted individually in artificial pulp chambers and distributed according to the following treatments: non-restored teeth stored for 24 hours submitted or not to bleaching procedures; non-restored teeth stored for 6 months submitted or not to bleaching procedures; restored teeth stored for 24 hours submitted or not to bleaching procedures; and restored teeth stored for 6 months submitted or not to bleaching procedures. The bleaching gel was left in contact with the enamel surface for 15 minutes (1 application) or for 45 minutes (3 applications of 15 minutes each). The extracts (culture medium in contact to the dentin surface of the discs + bleaching agents components that diffused across the discs) were collected and applied on previously cultured MDPC-23 cells (12.500 cells/cm2) for 1 hour. Cell metabolism was evaluated by the MTT assay and cell morphology by scanning electron microscopy. One application of bleaching gel in the enamel surface of the discs caused a significant decrease in cell metabolism only in the restored discs in comparison with control discs (unbleached and non-restored discs stored for 24 hours) and unbleached restored discs, regardlles of the storage time (Tukey, p<0.05). On the other hand, bleaching agent applied for three consecutive times on enamel caused a significant decreased in cell metabolism in all bleached discs (Mann- Whitney, p<0.05). However, there were no differences between... (Complete abstract click electronic access below)
55

Eficácia e sensibilidade dental resultante do clareamento dental de consultório com 6¢ H2O2/TiO_N. Estudo clínico randomizado controlado

Bortolatto, Janaína Freitas [UNESP] 19 September 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-09-19. Added 1 bitstream(s) on 2015-06-18T12:48:53Z : No. of bitstreams: 1 000830322.pdf: 1234837 bytes, checksum: 097154e03c13f16cbff4c473650d4b60 (MD5) / Coordenação de Pessoal de Nível Supwerior (Capes) / Este trabalho comparou aeficácia e a sensibilidade dental resultante do uso de um agente clareador composto por 6% peróxido de hidrogênio contendo nanopartículas de dióxido de titânio dopado por nitrogênio (PH6) com um clareador tradicional composto por 35% peróxido de hidrogênio (PH35); ambos fotocatalisados por luz híbrida composta de LED/Laser. Participaram deste estudo clínico controlado, randomizado, com triplo cegamento e amostras pareadas, 48 voluntários, maiores de 18 e menores de 28 anos, distribuídos aleatoriamente em 2 grupos experimentais: PH6 (teste) e PH35 (controle). Foram realizadas 2 sessões clínicas de clareamento com intervalo de 7 dias entre elas. Em cada sessão foram realizadas 2 aplicações consecutivas do clareador. Em cada uma delas, o gel clareador foi aplicado por 12 minutos, sendo fotocatalisado de forma intermitente por metade deste tempo. A eficácia (E) foi determinada pela variação de cor (ΔE), registrada por espectroscopia de refletância avaliada nos tempos T0 (baseline), após a 1ª. sessão de clareamento (T1) e após a 2ª. sessão (T2). A sensibilidade dental (S) foi caracterizada segundo Ocorrência (OS), Intensidade (IS), Tipo (TS) e Duração (DS). A eficácia foi analisada por ANOVA de medidas repetidas e teste post hoc de Bonferroni e a sensibilidade dental foi analisada de forma descritiva e 20 inferencial por meio do teste de Qui-Quadrado (α=0,05). Os testes apontaram valores de ΔE significativamente maiores para PH35 no T2. Para PH6, o clareamento foi o mesmo nos dois momentos. PH35 apresentou maior ocorrência de sensibilidade que PH6. Intensidade e duração da sensibilidade foram maiores para o grupo PH35. O tipo de sensibilidade mais citado pelos voluntários foi em choque. Em pacientes com idade entre 18 e 28 anos de idade, PH35 promoveu maior clareamento e maior sensibilidade dental que PH6. PH6 deve ser a opção de escolha para clareamento dental de consultório. / This study compared the efficacy and tooth sensitivity resulting from use of a bleaching agent composed of 6% hydrogen peroxide containing nanoparticles of nitrogen-doped titanium dioxide (PH6) with a traditional bleaching agent containing 35% hydrogen peroxide (PH35); both agents were activated by a hybrid LED/Laser light. 48 volunteers between 18 and 28 years of age participated in this randomized, controlled, triple-blinded clinical study with paired samples. They were randomly divided in 2 groups: PH6 (test) and PH35 (control). Two clinical sessions were performed with an interval of 7 days between them. In each session, two consecutive applications of the bleaching agent were performed. In each of them, the bleaching agent was applied for 12 minutes, activated intermittently for half of the duration. Efficacy (E) was determined by color alteration (ΔE), recorded with reflectance spectroscopy. It was assessed at T0 (baseline), after the 1st. bleaching session (T1) and after the 2nd. session (T2). Tooth sensitivity (S) was characterized according to Occurrence (OS), Intensity (IS), Type (TS) and Duration (DS). Efficacy was analyzed by repeated measures ANOVA and post hoc Bonferroni test and tooth sensitivity was analyzed descriptively and inferentially by means of chi-squared test (α=0.05). 23 The tests showed significantly higher values of ΔE for PH35 in T2. For PH6, bleaching was the same in both sessions. PH35 showed a higher occurrence of sensitivity than PH6. Intensity and duration of sensitivity were greater for the PH35 group. The majority of volunteers classified the type of pain experienced in their sensitivity in the form of a shock. For patients aged between 18 and 28 years old, PH35 promoted higher tooth bleaching and greater sensitivity than PH6. PH6 should be the option of choice for dental office bleaching.
56

Resistência á fratura e avaliação da microdureza dentinária de coroas dentais submetidas a diferentes protocolos de clareamento intracoronário

Galoza, Marina Oliveira Gonçalves [UNESP] 17 March 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-17Bitstream added on 2015-01-26T13:30:34Z : No. of bitstreams: 1 000805735_20170502.pdf: 449818 bytes, checksum: f8743f496c4b3be23f5e43a799d440bb (MD5) Bitstreams deleted on 2017-05-05T11:53:11Z: 000805735_20170502.pdf,. Added 1 bitstream(s) on 2017-05-05T11:53:57Z : No. of bitstreams: 1 000805735.pdf: 630418 bytes, checksum: ee891f94b41453c2d4b1dd82b2f97612 (MD5) / The purpose of this study was to evaluate the effect of the hydrogen peroxide and the carmine red pigment (CR) at 3:1 and 1:1 ratio, on the fracture resistance and dentin microhardness of bovine teeth submitted to tooth bleaching. Forty endodontically treated incisors were subjected to bleaching and divided into: G1(WHP3): 35% HP with CR (Whiteness HP) at 3:1 ratio; G2(WHP1) : 35% HP (Whiteness HP) with CR at 1:1 ratio ; G3(OPA): 38% HP (Opalescence Boost) e G4(CT): control group. Three bleaching sessions were performed with an interval of 7 days between them; the bleaching gel was applied to the buccal surface and placed inside the pulp chamber. 7 days after from the last bleaching session, the teeth were submitted to the fracture resistance test at the testing machine. Similar bleaching protocols were used in other identical groups to assess the reduction of dentin microhardness. The microhardness was measured, using knoop microhardness, before and after 4 sessions of bleaching protocols. G2 presented lower fracture resistance than G4 (p <0.05), but similar to G1 and G3 (P> 0.05).The dentin microhardness reduction was similar among the groups. Hydrogen peroxide and pigment at 1:1 ratio caused fracture resistance reduction, when compared to control group, but did not influence on dentin microhardness.
57

Ação do fluor na microdureza do esmalte humano submetido a dois tipos de agentes clareadores

Cunha, Lia Alves da [UNESP] 13 May 2005 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-05-13Bitstream added on 2015-01-26T13:30:28Z : No. of bitstreams: 1 000321042.pdf: 4778583 bytes, checksum: c36db84ae025a0bd3413bbc08735c08f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a capacidade do flúor de induzir a remineralização do esmalte humano submetido às técnicas de clareamento caseiro e profissional. Sessenta dentes foram divididos em cinco grupos: G1 - controle; G2- peróxido de carbamida a 10%; G3 - peróxido de carbamida a 10% e flúor a 0,05%; G4 - peróxido de hidrogênio a 35%; G5 - peróxido de hidrogênio a 35% e flúor a 0,05%. A microdureza Vickers de todos os corpos-de-prova foi mensurada antes e após o tratamento. Posteriormente foram realizadas análises em Espectrômetro de Absorção Atômica (EAA) e em Microscopia Eletrônica de Varredura (MEV). Os dados foram submetidos à análise estatística de variância e testes de Dunnett e Tukey. Os resultados evidenciaram redução significante da microdureza do esmalte clareado e o peróxido de carbamida promoveu redução significativamente maior do que o peróxido de hidrogênio. Dentes expostos ao flúor apresentaram menor redução da microdureza, sendo que essa diferença não foi significante nos dentes clareados com peróxido de carbamida e significante nos dentes clareados com peróxido de hidrogênio. Por meio da análise em EAA, observou-se que os grupos que não foram expostos ao flúor perderam mais cálcio do que os seus correspondentes que foram remineralizados. Ao MEV apresentaram-se alterações na morfologia da supertfcie do esmalte nos dentes clareados, sendo que estas não estavam distribuídas uniformemente em toda a superfície. Concluiu-se que a fluorterapia é um método adequado para minimizar a redução da microdureza após o clareamento caseiro ou de consultório / The aim of this study was to evaluate the ability of fluoride to induce remineralizatian of the human dental enamel subjected to nightguard vital bleaching and professional bleaching. Sixty teeth were divided into five groups: control; 10% peroxide carbamide; 10% peroxide carbamide and 0.05% fluoride; 35% hydrogen peroxide; 35% hydrogen peroxide and 0.05% fluoride. The Vickers microhardness of all specimens was measured before and after treatment. Complementary analysis comprised Atomic Absorption Spectrometry (AAE) and Scanning Electron Microscopy (SEM). Data were subjected to statistical analysis of variance (ANOVA), Dunnett's and Tukey's tests. The results revealed that there is significant reduction of enamel microhardness when subjected to the bleaching agents, compared to the control group. Carbamide peroxide promoted reduction of microhardness statistically bigger than hydrogen peroxide. The specimens that were exposed to fluoride showed a statistically significant smaller reduction of microhardness, compared with those not treated with fluoride. This difference was non-significant in teeth treated with carbamide peroxide and significant in teeth treated with hydrogen peroxide. Analysis by AAE .displayed that the groups not exposed to fluoride lost more calcium than their correspondents with remineralization. The SEM findings revealed morphologic changes in the enamel surface of bleached teeth, though these were not uniform through the entire surface. It was concluded that fluortherapy is an adequate method to minimize reduction of microhardness after nightguard or in-office vital bleaching
58

Novos parâmetros para o clareamento dental: avaliação da eficácia, citotoxicidade e efeitos moleculares

Soares, Diana Gabriela de Sousa [UNESP] 28 March 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-28Bitstream added on 2015-01-26T13:30:19Z : No. of bitstreams: 1 000806001_20170328.pdf: 531116 bytes, checksum: 4bcef8dc36e6fadb7f840876180a7545 (MD5) Bitstreams deleted on 2017-03-31T12:19:25Z: 000806001_20170328.pdf,. Added 1 bitstream(s) on 2017-03-31T12:20:23Z : No. of bitstreams: 1 000806001.pdf: 3239201 bytes, checksum: 56301903e59b57f9f74a836016abf9ac (MD5) / Nesta pesquisa, foram analisadas a eficácia clareadora, citotoxicidade e características fenotípicas de células pulpares expostas a protocolos de clareamento de consultório experimentais. No primeiro estudo, discos de esmalte/dentina foram submetidos a 6 sessões clareadoras, caracterizadas por 1 ou 3 aplicações de peróxido de hidrogênio (H2O2) a 35% ou 17,5%, por 5 ou 15 min, ou de peróxido de carbamida (PC) a 37%, por 10 ou 20 min. A alteração de cor (E) e quantificação da difusão de H2O2 (violeta leuco-cristal/peroxidase) foram avaliadas. Todos os protocolos testados promoveram alteração significativa de cor associados a redução na difusão de H2O2; no entanto, o gel com PC apresentou os piores resultados (Traço de Pilai; Bonferroni/p<0,05). Apenas os protocolos 35% H2O2/ 1x 15 e 3x 5 min, 17,5% H2O2/ 3x 15 min e 37% PC/ 3x 20 min apresentaram valores de E similares ao protocolo tradicional (35%/ 3x 15 min) em até 6 sessões de clareamento (ANOVA; SNK e Tamhane/p>0.05). No segundo estudo, foi avaliada a citotoxicidade trans-amelodentinária causada pela aplicação de protocolos experimentais usando 35% H2O2/ 1x 15 e 1x 5 min e 17,5% H2O2/ 3x 15, 1x 15 e 1x 5 min. O protocolo 35% H2O2/ 3x 15 min foi empregado como controle positivo. Os discos de esmalte/dentina foram adaptados em dispositivos trans-well, os quais foram posicionados sobre células odontoblastóides (MDPC-23) e cultura primária de células pulpares humanas (HDPCs) previamente semeadas. A viabilidade (MTT) e morfologia celular (MEV) foram avaliadas imediatamente e 72 h pós-clareamento, bem como o estresse oxidativo e lesão à membrana celular (microscopia de fluorescência). Todos os protocolos experimentais avaliados reduziram significativamente o dano celular quando comparados ao controle positivo (Kruskal-Wallis; Mann-Whitney/p<0,05). Esta redução foi tempo/concentração dependente. As células expostas aos protocolos com o gel contendo 17,5% de... / In this study, the bleaching effectiveness, cytotoxicity and phenotypic characteristic of dental pulp cells exposed to experimental in-office bleaching protocols were analyzed. In the first study, enamel/dentin discs were subjected to 6 bleaching sessions, composed by 1 or 3 applications of a 35%- or 17.5%-H2O2 (hydrogen peroxide) gel, during 5 or 15 minutes, or by a 37%-CP (carbamide peroxide) gel, applied for 10 or 20 minutes. Color change (E) and H2O2 diffusion (leucocrystal violet/ peroxidase) were analyzed. All the tested protocols promoted significant color alteration and reduction of H2O2 diffusion; however, the CP gel presented the worst results (Pillai’s trace/ Bonferroni test; p<0.05). Only the protocols 35%-H2O2/ 1x 15, 35%-H2O2/ 3x 5 min, 17.5%-H2O2/ 3x 15 min and 37%-CP 3x 20 min presented similar E values than traditional protocol (35%-H2O2/ 3x 15 min) up to 6 sessions (ANOVA; SNK and Tamhane tests/p>0.05). In the second study, the trans-enamel and trans-dentinal cytotoxicity on dental pulp cells of selected experimental bleaching protocols (35%-H2O2/ 1x 15 and 1x 5 min; 17.5%-H2O2/ 3x 15, 1x 15 and 1x 5 min) were tested. The protocol 35%-H2O2/ 3x 15 min was considered as the positive control group. The enamel/dentin discs were adapted to trans-wells devices, which were positioned over odontoblast-like cells (MDPC-23) and primary culture of human dental pulp cells (HDPCs) previously seeded on culture plates. The cell viability (MTT) and morphology (SEM) were evaluated immediately and 72 h post-bleaching, as well as oxidative stress and cell membrane damage (fluorescence microscopy). The experimental protocols promoted significant minimization of cell damage, for all evaluated parameters, when compared to positive control, in a time/concentration fashion (Kruskal-Wallis; Mann-Whitney/ p<0.05). Cells exposed to protocols with the 17.5%-H2O2 gel presented cell recovery capability in around 50% three days after bleaching...
59

Efeito de diferentes fontes luminosas e pré-condicionamento do esmalte na alteração de cor, penetração de H2O2 e citotoxicidade em dentes clareados

Gonçalves, Rafael Simões [UNESP] 20 March 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-20Bitstream added on 2015-03-03T12:07:21Z : No. of bitstreams: 1 000799564.pdf: 1833747 bytes, checksum: bc2c015d22702f8198465027540e0a6a (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito do condicionamento ácido do esmalte dental e do uso de diferentes fontes luminosas (luz halógena, LED e, LED/LASER) com um produto clareador na alteração de cor, penetração do peróxido de hidrogênio e citotoxicidade ao longo do tempo. A alteração de cor (?E) e a quantificação do peróxido permeado foram realizadas em espectrofotômetro. O metabolismo celular foi avaliado pelo teste do MTT e a morfologia por MEV. Os resultados mostraram uma alteração progressiva nos valores de ?E em todos os tratamentos realizados, no entanto, não houve diferença nos valores de ?E e na permeação de peróxido de hidrogênio entre as condições experimentais. Verificou-se no teste MTT que o clareamento dentário produziu uma redução significativa no metabolismo celular, independentemente do uso ou não das fontes luminosas. O pré-condicionamento do esmalte dentário não influenciou no metabolismo celular em nenhum grupo. Conclui-se que a associação do produto clareador com diferentes fontes luminosas e/ou com o pré-condicionamento ácido do esmalte são poucos significativos na alteração de cor, penetração trans-amelodentinária de peróxido de hidrogênio, citotoxicidade e morfologia celular / This study evaluated the effect of acid etching of the enamel and the combination of different light sources (halogen light, LED and LED/LASER) with bleaching product on the color change, penetration of hydrogen peroxide and cytotoxicity during the time. The color change (?E) and the measurement of peroxide that permeated the tooth tissue were analyzed by spectrophotometer. Cell metabolism was evaluated by MTT assay and the morphology by SEM. The results showed no difference in the values of ?E and in the permeation of hydrogen peroxide in all experimental conditions. It was found that tooth whitening produced a significant reduction in cell metabolism, regardless of the use or not the light source. The preconditioning of the enamel did not influence the cellular metabolism in either group. It was concluded that the association of the bleaching product with different light sources and/or the preconditioning of the enamel are few significant in color change, trans-enamel and trans-dentinal penetration of hydrogen peroxide, cytotoxicity and cell morphology / FAPESP: 12/06066-0
60

Eficácia de agentes clareadores de venda livre associados ou não ao clareamento com Peróxido de Carbamida a 10 por cento /

Jurema, Ana Luiza Barbosa. January 2016 (has links)
Orientador: Taciana Marco Ferraz Caneppele / Banca: Eduardo Bresciani / Banca: Michele Baffi Diniz / Resumo: O objetivo deste estudo foi avaliar a cor, fluorescência, e microdureza de agentes clareadores de venda livre associados ou não ao clareamento com Peróxido de Carbamida a 10% (PC10%) e comparar sua eficácia ao do clareamento caseiro com gel de PC10%. Duzentos e dez espécimes de esmalte e dentina foram obtidos a partir de incisivos bovinos e manchados em caldo de manchamento durante 14 dias. Foram randomizados em dois grupos, um deles foi clareado previamente com Peróxido de Carbamida a 10% (PC) e o outro não. Cada grupo foi subdividido em 7 subgrupos de acordo com o produto (n = 15): PC-Lis e Lis- enxaguatório clareador (Listerine Whitening); PC-AG e AG - água deionizada; PC-E e E- escovação mecânica. PC-EConv e EConv - creme dental convencional (Colgate Total Clean Mint); PC-EPerox e EPerox (Colgate Luminous White Advanced); PC-EAbras e EAbras (Oral-B 3D White Luxe); e PC-EOpt e EOpt (Close Up Diamond Attraction) - dentifrícios clareadores. O grupo clareado com PC10% foi submetido a 14 dias de ciclos diários de clareamento caseiro associado aos tratamentos com agentes de venda livre. Após isso, todos os subgrupos passaram por ciclos de escovação ou enxágue durante 12 semanas. As medidas de cor, fluorescência e microdureza foram realizadas após o manchamento, após o clareamento com PC10% e após as 12 semanas dos tratamentos com os agentes clareadores de venda livre. Os dados de cor foram analisados pelo teste de análise de variância (ANOVA) e teste de Tukey de comparações múl... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract : the aim of this study was to evaluate color change, fluorescence and microhardness of different over-the-counter (OTC) whitening products, and to compare them with 10% carbamide peroxide (10%CP) gel. Two hundreds and ten enamel-dentin specimens were obtained from bovine incisors and stained in staining broth for 14 days, then randomly divided into 2 groups, one of them was bleached with 10%CP and the other was not bleached. Each group was divided into 7 subgroups according to type of product (n = 15): PC-Lis and Lis- whitening mouth rinse (Listerine Whitening); PC-AG and AG - deionized water; PC-E and E- mechanical brushing. PC-EConv and EConv - conventional dentifrice (Colgate Total Clean Mint); PCEPerox and EPerox (Colgate Luminous White Advanced); PC-EAbras and Eabras (Oral-B 3D White Luxe); and PC-EOpt and EOpt (Close Up Diamond Attraction) - whitening dentifrices. Bleached groups were submitted to daily cycles of at-home bleaching associated with OTC whitening products. Then, all subgroups were submitted to cycles of whitening of OTC whitening products. Color, fluorescence and microhardness were measured after staining and after bleaching with 10%CP and after 12 weeks of whitening treatment with OTC products. Color data was submitted for analysis of variance and Tukey's test for multiple comparisons, for microhardness and fluorescence, Tukey's test was used for bleached groups and paired t-test was used for non-bleached group. In comparison of OTC whitening agents with 10%CP bleaching was used Dunnet's test. Results for bleached group: ∆Eab* and ∆b* values was similar after 10%CP bleaching; after 12 weeks PC-Lis e PC-AG presented lower values of ∆Eab* and PC-Lis, PC-AG and PC-E presented lower values of ∆b*; fluorescence increased for all groups after 10%CP treatment and after 12 weeks, decreased significantly for PC-AG and PC-E. For microhardness there were not ....(Resumo completo, clicar acesso eletrônico abaixo) / Mestre

Page generated in 0.4594 seconds