• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 6
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[pt] ESTUDO EXPERIMENTAL DA INFLUÊNCIA DO COBRIMENTO NA INTERAÇÃO AÇO-CONCRETO EM ELEMENTOS SUJEITOS À COMPRESSÃO / [en] EXPERIMENTAL STUDY ON THE INFLUENCE OF CONCRETE COVER ON THE INTERACTION BETWEEN STEEL BARS AND CONCRETE IN ELEMENTS SUBJECTED TO COMPRESSION

WALTER EDGLEY DE OLIVEIRA 02 March 2009 (has links)
[pt] O presente trabalho trata da influência do cobrimento da armadura longitudinal sobre a resistência de aderência em regiões de emenda por traspasse de elementos de concreto armado comprimidos. Neste estudo foram ensaiados dezoito pilares de concreto armado com seção transversal de 200 mm x 150 mm e comprimento de 1100 mm, com armadura longitudinal composta de barras de aço CA-50 com diâmetro nominal de 12,5 mm e estribos de 5 mm. O arranjo da armadura longitudinal definiu três séries de pilares, sendo a Série 1 composta por seis pilares com a armadura longitudinal contínua, e as Séries 2 e 3 cada uma composta por seis pilares com a armadura longitudinal, tendo uma emenda por traspasse localizada na região da metade da altura do pilar de 470 cm e 235 mm de comprimento, respectivamente. Os ensaios consistiram na aplicação de uma força de compressão com uma excentricidade de 20 mm, sendo tal excentricidade aplicada apenas na direção da menor dimensão da seção transversal. Para os seis pilares de cada série o cobrimento da armadura longitudinal variou de 25 mm até que a metade do diâmetro da barra longitudinal ficasse exposta. Os resultados obtidos indicam que a influência do cobrimento sobre a capacidade do pilar resistir às solicitações torna-se visível quando a relação da espessura do cobrimento c e do diâmetro da barra fi é inferior a 0,4. Para pilares com barras emendadas por traspasse e com armadura exposta até a metade de seu diâmetro, a aderência na zona da emenda foi substancialmente afetada, provocando a ruptura do pilar sob forças inferiores às alcançadas em pilares com cobrimento adequado. / [en] The present work describes the influence of the concrete cover of the longitudinal reinforcement on the bond strength along the overlapping splice zones of compressed elements. Tests have been carried out on eighteen reinforced concrete columns, with cross section of 200 mm x 150 mm and 1100 mm of length. The longitudinal reinforcement consisted of CA-50 steel bars with nominal diameter of 12,5 mm and stirrups of 5 mm. Three series of columns (Serie 1, Serie 2 and Serie 3) were defined according to the arrangements of the longitudinal reinforcement: Series 1 composed by six columns with continuous longitudinal reinforcement; Series 2 and 3 composed by six columns each, presenting an overlapping splice of 470 mm and 235 mm of lenght, respectively. The columns were submited to a load apllied with an eccentricity of 20 mm in the direction of the smallest dimension of the cross section. In each series, the concrete cover varied from 25 mm to a value corresponding to the situation in which half of the diameter of the longitudinal bar was exposed. The results showed that the influence of the concrete cover on the column strength becomes relevant when the ratio c/ Ø of the cover thickness c to the bar diameter Ø is less than 0,4. For columns with overlapping splice and reinforcement exposed up to the half of diameter, the bond along the overlapping zone has been substancially affected, resulting in the column failure at lower loads when compared to columns with proper value of concrete cover.
2

Ação da carbonatação em vigas de concreto armado em serviço, construídas em escala natural e reduzida / Carbonation action in reinforced concrete beams under stress regime carried out on full and small scales

Silva, Valdirene Maria 30 January 2007 (has links)
Este trabalho apresenta uma análise do comportamento da frente de carbonatação em vigas de concreto armado sob tensão, em escala natural e reduzida, com a máxima condição de subarmação. As vigas foram construídas com e sem adição da sílica da casca de arroz e sílica de ferro silício ou silício metálico. Para cada viga em escala natural (agregado graúdo com D máx. = 19 mm) foi moldada uma em escala reduzida com o mesmo traço de concreto para estabelecer os mesmos parâmetros de comparação. As vigas foram curadas durante 7 dias e posteriormente submetidas à flexão, com o carregamento aplicado nos terços (L/3 da viga). Realizou-se o pré-condicionamento para a estabilização da umidade interna das vigas que foram expostas durante 28 dias em um ambiente com concentração de 50% de dióxido de carbono, umidade relativa de 65 \'+ OU -\' 5% e temperatura ambiente. Foram determinados: resistências à compressão simples axial, resistência à tração por compressão diametral, módulos de elasticidade e profundidade da frente de carbonatação em corpos-de-prova cilíndricos. A profundidade da frente de carbonatação em corpos-de-prova foi determinada para diferentes concentrações de dióxido de carbono. Também foi verificada a carbonatação ao longo das vigas em escala natural e reduzida e nas posições das fissuras. Para a previsão da profundidade da frente de carbonatação nas vigas, foram ajustadas equações para a representação da carbonatação na região das fissuras. Os resultados obtidos mostraram a eficiência da espessura do cobrimento, a eficácia dos modelos físicos reduzidos para realizar estudos de carbonatação e a tendência da carbonatação em elementos estruturais na condição de serviço. A frente de carbonatação difere na posição das fissuras, evidenciando um comportamento diferente quando comparado com corpos-de-prova. A análise microestrutural ilustrou o comportamento da frente de carbonatação em vigas de concreto armado, complementando o estudo experimental. Com base nos resultados obtidos pode-se afirmar que a simples adoção de concretos de alto desempenho para construção de elementos estruturais não é suficiente nas peças que contenham fissuras e que sejam submetidas a atmosferas ambientais agressivas. / This work reports on the behavior of carbonation in reinforced concrete beams under stress regime on full and small scales having the lowest possible frame. The beams were made with and without adding silica from rice husk and silica fume (Fe-Si). For each beam on a full scale (coarse aggregate with D máx. = 19 mm) another beam on a small scale was made with the same mix of concrete to maintain the same comparison parameter. The beams were cured for 7 days and subsequently submitted to flexure by applying a two-point loading (L/3 of beam). Humidity stabilization to stabilize internal humidity of beams exposed for 28 days in an environment with a concentration of 50% carbon dioxide, 65 \'+ OR -\' 5% of relative humidity and room temperature was carried out. The following was determined: axial compression strength, tensile splitting strength, young\'s modulus and carbonation depth in cylindrical specimens. The carbonation depth was determined in specimens with unlike carbon dioxide concentration. Moreover, carbonation along beams on full and small scales and in cracks was observed. To estimate the carbonation depth of the beams, equations were adjusted to represent the carbonation in cracks. The results show the efficiency in the thickness of the cover, efficiency of small-scale models for studies concerning carbonation and behavior of carbonation in the serviceability of structural elements. The carbonation depth differs in the position of cracks, showing behavior which is unlike the one compared to specimens. The microstructure analyses show the behavior of carbonation depth in reinforced concrete beams complementing the experimental study. The results show that it is not sufficient to use high performance concretes in structural elements for elements with cracks and in aggressive atmospheres.
3

ESTUDO DA CARBONATAÇÃO DA CAMADA DE COBRIMENTO DE PROTÓTIPOS DE CONCRETO COM ALTOS TEORES DE ADIÇÕES MINERAIS E CAL HIDRATADA / STUDY OF CARBONATION OF THE COVERCRETE LAYER OF PROTOTYPES OF CONCRETE WITH HIGH ADDITIONS CONTENTS AND LIME HYDRATED

Cadore, William Widmar 01 February 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this study deals the covercrete structural concrete layer with the use of hydrated lime in substitution in mass of the sand in ternary mixture of 70% of blast-furnace slag, 20%-fly ash and 10% of cement CPV-ARI (EVC) in comparison to reference with 100% CPV-ARI (R) and other ternary mixture of 70%-ground granulated blast-furnace slag, 20%-fly ash and 10%-cement CPV-ARI without addition of the hydrated lime (EV). Beams prototypes were molded, exposed in environmental curing for the study of the structural concrete covercre layer. The carbonation analysis was made in extracted testimonies at 91st and the 300th days. The depth of the testimonies was the following: layer 1 - 0 to 10 mm, layer 2 - 20 to 30 mm and layer 3 - 45 to 55 mm. The accelerated carbonation tests were accomplished in atmosphere with 5% of CO2 content, following RILEM CPC-18, after pre-conditioning. The analysis of the test results were in comparison of the mixtures with hydrated lime in relation to the mixtures without hydrated lime and the reference mixtures. It was observed that the addition of hydrated lime in the mixtures reduced the carbonated depths and consequently the carbonation coefficients. The presented results indicate that the hydrated lime addition reached the purpose restoring the alkaline reserve, reducing the carbonated dephts so much by the chemical as physical actions. In a general way, R and EV presented tendency of larger coefficients in the most internal layer (C1 < C3) and EVC contrary behavior (C1>C3). It was observed a paradox in resistance equality on concrete types with hydrated lime, with reduction of the coefficients to the 300th days compared to the 91st days. This behavior can be explained by the most compacts and homogeneous structure, since there was connection pores reduction of 50% up to 25nm and C-S-H increases with the age. However, the relationship among the accelerated and natural tests indicate that to the 300th days the accelerated effects process tend to be between 1,5 and 3,5 larger times than the natural tests. / Neste estudo foi verificado a camada de cobrimento estrutural do concreto com o uso da cal hidratada em substituição em massa da areia em mistura ternária de 70% de escória de alto forno, 20% cinza volante e 10% de cimento CPV-ARI (EVC) em comparação a traços de referência com 100% CPV-ARI (R) e outra mistura ternária de 70% de escória de alto forno, 20% cinza volante e 10% de cimento CPV-ARI sem adição da cal hidratada (EV). Para o estudo da camada de cobrimento do concreto estrutural foram moldados protótipos de vigas, expostos em cura ambiental, com extração de testemunhos aos 91 e aos 300 dias. A profundidade dos testemunhos foram as seguintes: camada 1 0 a 10mm, camada 2 20 a 30mm e camada 3 45 a 55mm. O ensaio de carbonatação acelerada foi realizado em atmosfera com teor de 5% de CO2, seguindo a RILEM CPC - 18, após précondicionamento. Foram adotadas 4, 8 e 12 semanas de exposição na câmara climatizada para traços de referência e 3, 6 e 9 para as misturas com adições minerais com e sem cal hidratada. Além dos ensaios acelerados, foram realizados ensaios de carbonatação natural bem como análise do pH e do CH. Os resultados apresentados indicam que a adição da cal hidratada atingiu sua finalidade repondo a reserva alcalina, reduzindo as profundidades carbonatadas tanto pela ação química como física. De uma maneira geral, R e EV apresentaram tendência de maiores coeficientes na camada mais interna (C1<C3) e EVC comportamento contrário (C1>C3). Em igualdade de resistência foi observado um paradoxo nas misturas com adição de cal, com redução dos coeficientes aos 300 comparados aos 91. Este comportamento pode ser explicado pela estrutura mais homogênea e compacta, já que houve redução de 50% da interconctividade dos poros até 25mm com a idade e aumento do C-S-H com a idade. Contudo, a relação entre os ensaios acelerados e naturais indicam que aos 300 dias os efeitos do processo acelerado tendem a ser entre 1,5 e 3,5 vezes maiores do que os ensaios naturais.
4

Ação da carbonatação em vigas de concreto armado em serviço, construídas em escala natural e reduzida / Carbonation action in reinforced concrete beams under stress regime carried out on full and small scales

Valdirene Maria Silva 30 January 2007 (has links)
Este trabalho apresenta uma análise do comportamento da frente de carbonatação em vigas de concreto armado sob tensão, em escala natural e reduzida, com a máxima condição de subarmação. As vigas foram construídas com e sem adição da sílica da casca de arroz e sílica de ferro silício ou silício metálico. Para cada viga em escala natural (agregado graúdo com D máx. = 19 mm) foi moldada uma em escala reduzida com o mesmo traço de concreto para estabelecer os mesmos parâmetros de comparação. As vigas foram curadas durante 7 dias e posteriormente submetidas à flexão, com o carregamento aplicado nos terços (L/3 da viga). Realizou-se o pré-condicionamento para a estabilização da umidade interna das vigas que foram expostas durante 28 dias em um ambiente com concentração de 50% de dióxido de carbono, umidade relativa de 65 \'+ OU -\' 5% e temperatura ambiente. Foram determinados: resistências à compressão simples axial, resistência à tração por compressão diametral, módulos de elasticidade e profundidade da frente de carbonatação em corpos-de-prova cilíndricos. A profundidade da frente de carbonatação em corpos-de-prova foi determinada para diferentes concentrações de dióxido de carbono. Também foi verificada a carbonatação ao longo das vigas em escala natural e reduzida e nas posições das fissuras. Para a previsão da profundidade da frente de carbonatação nas vigas, foram ajustadas equações para a representação da carbonatação na região das fissuras. Os resultados obtidos mostraram a eficiência da espessura do cobrimento, a eficácia dos modelos físicos reduzidos para realizar estudos de carbonatação e a tendência da carbonatação em elementos estruturais na condição de serviço. A frente de carbonatação difere na posição das fissuras, evidenciando um comportamento diferente quando comparado com corpos-de-prova. A análise microestrutural ilustrou o comportamento da frente de carbonatação em vigas de concreto armado, complementando o estudo experimental. Com base nos resultados obtidos pode-se afirmar que a simples adoção de concretos de alto desempenho para construção de elementos estruturais não é suficiente nas peças que contenham fissuras e que sejam submetidas a atmosferas ambientais agressivas. / This work reports on the behavior of carbonation in reinforced concrete beams under stress regime on full and small scales having the lowest possible frame. The beams were made with and without adding silica from rice husk and silica fume (Fe-Si). For each beam on a full scale (coarse aggregate with D máx. = 19 mm) another beam on a small scale was made with the same mix of concrete to maintain the same comparison parameter. The beams were cured for 7 days and subsequently submitted to flexure by applying a two-point loading (L/3 of beam). Humidity stabilization to stabilize internal humidity of beams exposed for 28 days in an environment with a concentration of 50% carbon dioxide, 65 \'+ OR -\' 5% of relative humidity and room temperature was carried out. The following was determined: axial compression strength, tensile splitting strength, young\'s modulus and carbonation depth in cylindrical specimens. The carbonation depth was determined in specimens with unlike carbon dioxide concentration. Moreover, carbonation along beams on full and small scales and in cracks was observed. To estimate the carbonation depth of the beams, equations were adjusted to represent the carbonation in cracks. The results show the efficiency in the thickness of the cover, efficiency of small-scale models for studies concerning carbonation and behavior of carbonation in the serviceability of structural elements. The carbonation depth differs in the position of cracks, showing behavior which is unlike the one compared to specimens. The microstructure analyses show the behavior of carbonation depth in reinforced concrete beams complementing the experimental study. The results show that it is not sufficient to use high performance concretes in structural elements for elements with cracks and in aggressive atmospheres.
5

[en] INFLUENCE OF TRANSVERSE REINFORCEMENT AND OF CONCRETE COVER OF LONGITUDINAL REINFORCEMENT ON THE ULTIMATE STRENGTH OF CONCRETE COLUMNS / [pt] INFLUÊNCIA DA ARMADURA TRANSVERSAL E DO COBRIMENTO DA ARMADURA LONGITUDINAL NA RESISTÊNCIA DE PILARES DE CONCRETO

CONSUELO BELLO QUINTANA 24 March 2006 (has links)
[pt] Neste trabalho é feito o estudo da influência do cobrimento da armadura longitudinal e dos grampos suplementares na resistência de pilares de concreto submetidos à compressão excêntrica. Para este fim foram ensaiados pilares curtos, com armadura longitudinal contínua e pilares com emenda na armadura. Foi elaborado um modelo para o cálculo da distribuição da tensão normal e da tensão de aderência nas barras de emendas comprimidas que reproduziu bem o verificado experimentalmente. Mostra-se a importância da tensão de ponta na transmissão de forças na emenda. Se alerta sobre como a técnica normalmente empregada no reparo dos pilares onde as armaduras apresentam corrosão, que consiste na retirada parcial ou total do que restou do cobrimento para o tratamento e/ou substituição da armadura, e posterior reposição da camada de cobrimento, pode levar a ruptura do elemento por perda de aderência. Mostra-se como não colocar os grampos suplementares pode levar a perda da estabilidade do elemento. / [en] In this work, the influence of the longitudinal reinforcement cover and supplementary transversal reinforcement on the ultimate strength of the concrete columns under eccentric compression is studied. For this purpose, tests on short columns with continuum and lapped spliced bars were carried out. A theoretical model for the calculation of the stress and bond distributions on the splice length is proposed and tested with the experimental data of this work, showing a good agreement. The relevance of the end bearing effect on the transmission of the forces in the splice is shown. An alert again the usual technique used to repair the corroded bars inside the column, i.e., to remove partially or totally the remaining concrete cover to treat or substitute the damaged reinforcement bars, and lately to put back the concrete cover. This technique may provide the element failure by the lost of bond between the remaining concrete surface and reinforcement bars. It is shown how the absence of supplementary transversal reinforcement can lead to the instability of column.
6

Investigação da relação entre os parâmetros de projeto das estruturas de concreto armado visando à durabilidade

Pacheco, Fernanda 11 April 2016 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2016-06-13T17:14:24Z No. of bitstreams: 1 Fernanda Pacheco_.pdf: 2975053 bytes, checksum: ee3a33ed030278d4b1f1df978656449b (MD5) / Made available in DSpace on 2016-06-13T17:14:24Z (GMT). No. of bitstreams: 1 Fernanda Pacheco_.pdf: 2975053 bytes, checksum: ee3a33ed030278d4b1f1df978656449b (MD5) Previous issue date: 2016-04-11 / Nenhuma / Cresce o interesse pelo estudo da durabilidade das estruturas de concreto, devido à norma de desempenho e seus critérios de vida útil das edificações, somado à percepção da perda precoce de vida útil das construções. Há definições em normas técnicas e na literatura científica sobre os parâmetros de projeto das estruturas de concreto armado, como a relação água/cimento, consumo de cimento, resistência mecânica à compressão e cobrimento das armaduras. Porém, até o presente momento no Brasil, não estão estabelecidas as relações entre estas características para proporcionar maior flexibilidade ao profissional na especificação dos parâmetros das estruturas visando à durabilidade. Soma-se a esta lacuna a necessidade de consideração das classes de agressividade, definidas em virtude dos agentes deletérios às estruturas. Neste contexto, o objetivo deste trabalho é a definição da relação entre os parâmetros dos concretos e como estes variam em função das classes de agressividade ambiental, focando no cobrimento necessário para garantia da durabilidade das estruturas. Dessa forma, propôs-se o estudo com concretos, em concordância com as especificações de normas, verificando a frente de ataque das estruturas por modelos teóricos de previsão de vida útil, somados à realização dos ensaios acelerados de deterioração de carbonatação acelerada e névoa salina. Foram definidos períodos de realização do ensaio que representam cada uma das classes de agressividade da ABNT NBR 6118:2014, norteados pelos modelos teóricos de deterioração das estruturas. Após, cada um dos quatro traços de concreto foi submetido a diferentes agressividades. Diante disto, determinou-se o impacto no cobrimento das armaduras para cada classe de agressividade, mais amena ou mais severa. Cada um destes traços foi avaliado quanto às características físicas e mecânicas. Verificou-se que o cobrimento necessário às armaduras varia de maneira linear com a resistência à compressão dos traços, denotando a possibilidade de considerar mais de uma classe de resistência de concreto e o cobrimento nas diferentes classes de agressividade, como ocorre em algumas normas técnicas internacionais de dimensionamento de estruturas. Destaca-se que a diferença do cobrimento necessário em relação às classes de agressividade se torna mais acentuada quando utilizados concretos de resistência superior a 30MPa. Ainda, percebeu-se que o ataque por íons cloreto é mais severo que a carbonatação, tendo determinado, na maioria das verificações, a espessura mínima de concreto para garantir a durabilidade almejada. Por fim, a análise estatística apontou influência significativa do traço na frente de carbonatação e apenas entre os traços 1 e 4 em relação à resistência frente a névoa salina. / The amount of studies that focus on concrete structures durability has been increasing because of the new Brazilian Standard regarding to Performance and its life cycle criteria for buildings, added to the perception of early lifespan loss of buildings. There are definitions in technical standards and scientific literature about project parameters of concrete structures, as water/cement, cement consumption, compressive strength and concrete covering. However, up to this date in Brazil, no relations have been established between these characteristics in a way to grant more flexibility for the professionals when specifying parameters of structures focusing on durability. Besides this gap, there is a necessity to consider the aggressiveness classes established by agents which are deleterious to structures. Within this context, this study aims to define the relations between the parameters of different concretes compositions and how they differentiate due to the environmental aggressiveness classes, focusing on the necessary covering to ensure durability. Thus, the study of concretes according to Standard specifications was proposed, besides checking the attack front of structures through theoretical life cycle prediction models, and the conduction of accelerated tests of carbonation and salt spray. The test periods that were defined represent each one of the aggressiveness classes of ABNT NBR 6118, guided by the theoretical models of deterioration of structures. After this, each of the four concrete mixes was submitted to different aggressiveness. Thereby, it was possible to determine the impact in the coating of the reinforcement for each aggressiveness class, whether milder or more severe. Each mix was evaluated for physical and mechanical characteristics. It was found out that the concrete cover necessary for the steel bars varies linearly with the compressive strength resistance of the mixes, indicating the possibility to consider more than one resistance class of concrete and coating within different aggressiveness classes, as occurs in some international technical standards of dimensioning of structures. It is noteworthy that the difference of concrete cover necessary in relation to aggressiveness classes becomes rougher when concretes with compressive strength higher than 30 MPa are used. Another observation is that that the attack for chloride ions is more severe than carbonation, determining, in most verifications, the minimum thickness to ensure the expected durability. Lastly, the statistical analysis pointed out a significant influence of the mix in the carbonation front and between the mixes 1 and 4 for salt spray.
7

MICROESTRUTURA DO COBRIMENTO DE CONCRETOS COM ALTOS TEORES DE ESCÓRIA E CINZA VOLANTE ATIVADAS POR CIMENTO PORTLAND E CAL HIDRATADA / MICROSTRUCTURE OF COVERCRETE CONCRETES WITH HIGH CONTENTS OF SLAG AND FLY ASH ACTIVATED BY PORTLAND CEMENTE AND HYDRATED LIME

Brizola, Rodrigo Matzenbacher 08 March 2007 (has links)
In the history of the concrete structures there was a time in which the mechanical resistance was the most important property for the designers. However due to amount of pathologies in the concrete structures and your respective worn-out amounts in recovery, other feature is being prioritized: the durability. And for environmental reasons as global heating, pollution and the raw materials decrease, the sustentability is prioritized. Aiming at collaborate to these factors these paper has as objective analyzes the microstructure of the covercrete with substitution in mass of 90% of cement for mineral additions. Were researched three types of concretes reference concrete (100%CPV-ARI), concrete with 70%Slag+20%FlyAsh and other similar mixture with addition of 20% of hydrated lime with the intention of partially restoring the hydroxide of calcium consumed by the pozzolanics reactions - named respectively of R, EV and EVC. Aims at, more specifically, to establish the differences microstructures of the covercrete of the prototypes(beams-70x20x15cm), through the tests of combined water, x-ray diffraction and scanning electron microscopy. For comparison effect, compressive strength test were also accomplished in molded cylinders(10x20cm) and cured in humid camera and in the cylinders(10x20cm) extracted of the cured prototypes in environmental conditions after 7 days of humid cure. Were studied three relationships a/ag: 0.40, 0.60 and 0.80 for the concrete R and 0.30, 0.40 and 0.50 for the concretes with additions, obtaining resistance between 20 and 70MPa. The tests of the microstructure were accomplished in the 91 and 300 days, with samples starting from the surface of the prototypes, in layers, in the depths of: 0-1.0cm(C1), 2.0-3.0cm(C2) and 4.5-5.5cm(C3). Evolution of the strength was accompanied in the ages of 28, 91, 182 and 300 days. Results were analyzed in equality of a/ag and compressive strength. For a/ag 0.40 and 0.50, to 28 days of age, in relation to reference concrete, the strength of the concrete EV was 54.0% on average of this, and the concrete EVC it was 68.5%. In the final age of 300 days, the percentile are of 72.5% and 76%. In both tests ages, with the increase of the depth of the layer occurs: decrease in the intruded volume total mercury, decrease in the tenor of combined water for the reference concrete and increment in the concretes with additions, decrease in the intensity of pick of the hydroxide of calcium in the three mixtures, decrease in the intensity of pick of the hydrated silicate for the reference concrete and increment in the concretes with mineral additions. Analysis on scanning electron microscopy showed refinement in the size of the grains, larger compact and uniformity in the mixtures with additions / Na história das estruturas de concreto houve período no qual a resistência mecânica foi a propriedade mais importante para os projetistas. Porém, devido ao surgimento de manifestações patológicas nas estruturas de concreto e seus respectivos montantes gastos em recuperação, outro aspecto também está sendo considerado: a durabilidade. Por motivos ambientais como aquecimento global, poluição e diminuição das matérias-primas, prioriza-se também a sustentabilidade. Visando colaborar com estes fatores o presente trabalho tem como objetivo analisar a microestrutura da camada de cobrimento de concretos com substituição em massa de 90% de cimento Portland por adições minerais. Foram pesquisadas três misturas: concreto de referência (100%CPV-ARI), concreto com 70%Escória+20%CinzaVolante e outra mistura similar com adição de 20% de cal hidratada com o intuito de repor parcialmente o hidróxido de cálcio consumido pelas reações pozolânicas as quais foram nomeadas respectivamente de R, EV e EVC. Objetiva, mais especificamente, estabelecer as diferenças microestruturais da camada de cobrimento de protótipos (vigas 70x20x15cm), através dos ensaios de porosimetria por intrusão de mercúrio, água combinada, difração de raios-X e microscopia eletrônica de varredura. Para efeito de comparação, também foram realizados ensaios de resistência à compressão em corpos-de-prova (10x20cm) moldados e curados em câmara úmida e em testemunhos (10x20cm) extraídos dos protótipos curados em condições ambientais após 7 dias de cura úmida. Foram estudadas três relações a/ag: 0.40, 0.60 e 0.80 para o concreto R e 0.30, 0.40 e 0.50 para os concretos com adições, obtendo resistências entre 20 e 70MPa. Os ensaios da microestrutura foram realizados aos 91 e 300 dias, com amostras a partir da face dos protótipos, em três camadas, nas profundidades: 0-1cm(C1), 2- 3cm(C2) e 4.5-5.5cm(C3). A evolução da resistência foi acompanhada nas idades de 28, 91, 182 e 300 dias. Os resultados foram analisados em igualdade de relação a/ag e resistência à compressão. Para as relações a/ag 0.40 e 0.50, aos 28 dias de idade, em relação ao concreto de referência, a resistência do concreto EV foi em média 54.0% deste, e o concreto EVC foi 68.5%. E na idade final de 300 dias, os percentuais são de 72.5% e 76%. Em ambas as idades de ensaio, com o aumento da profundidade da camada ocorreu: decréscimo no volume total intrudido de mercúrio, decréscimo no teor de água combinada para o concreto de referência e acréscimo nos concretos com adições, decréscimo na intensidade de pico do hidróxido de cálcio nas três misturas, decréscimo na intensidade de pico do silicato de cálcio hidratado para o concreto de referência e acréscimo nos concretos com adições minerais. A análise das micrografias mostrou refinamento no tamanho dos grãos, maior densificação e uniformidade nas misturas com adições

Page generated in 0.054 seconds