• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Clonagem de imagens via absorção induzida eletromagneticamente / Imaging cloning by electromagnetically induced absorption

Fernandez Apolinario, Ulices, 1988- 12 October 2015 (has links)
Orientador: Luís Eduardo Evangelista de Araujo / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-29T14:34:13Z (GMT). No. of bitstreams: 1 FernandezApolinario_Ulices_D.pdf: 32632596 bytes, checksum: 913293ad92a80bba8b449b4814411610 (MD5) Previous issue date: 2015 / Resumo: Nesta tese, propomos, descrevemos e desenvolvemos um novo mecanismo de clonagem de imagens ópticas baseado no efeito atômico coerente da absorção induzida eletromagneticamente ("EIA"). Estudamos experimentalmente a transferência de uma imagem impressa em um feixe forte de acoplamento para um feixe fraco de prova ressonante em um sistema atômico de rubídio de quatro níveis do tipo N degenerado. Nos experimentos, uma imagem bidimensional correspondente a um padrão de linhas horizontais é aplicada ao feixe de acoplamento e transferida para um feixe de prova, de mesma frequência mas polarização ortogonal ao laser de acoplamento. A clonagem de imagem é estudada em função da potência, dessintonia e grau de coerência espacial do feixe de acoplamento. Nós mostramos experimentalmente que o feixe de prova clonado que carrega a imagem é transmitido sem a difração usual. Apresentamos um modelo teórico, para o caso de um feixe de acoplamento espacialmente coerente, que prevê que as características transversais do feixe de acoplamento são transferidas para o feixe de prova de maneira eficiente, apesar da imagem de controle sofrer distorções devido a difração durante a propagação. De fato, as imagens clonadas podem ser muito melhores do que as imagens de acoplamento originais, com estruturas reduzidas em tamanho por aproximadamente um fator de 2. Experimentalmente, verificamos que quanto menor o grau de coerência da luz, melhor é a imagem clonada quando comparada com a imagem de acoplamento a uma mesma distância de propagação. Uma comparação com outras técnicas de clonagem estudadas na literatura, com luz espacialmente coerente, mostra que o nosso mecanismo apresenta um desempenho similar a elas, com uma transmissão máxima da imagem clonada pelo vapor atômico de aproximadamente 10% / Abstract: In this thesis, we propose, describe and develop a new optical imaging cloning mechanism based on the coherent atomic effect of electromagnetically induced absorption ("EIA"). We experimentally study the transfer of an image imprinted onto a strong coupling beam to a resonant weak probe beam in a rubidium atomic system in a degenerate four-level N configuration. In the experiments, a two-dimensional image corresponding to a pattern of horizontal lines is imprinted onto the coupling beam and transferred to a probe beam of the same frequency, but with orthogonal polarization to the coupling laser. Image cloning is studied as a function of power, detuning and the degree of spatial coherence of the coupling beam. We show experimentally that the cloned probe beam carrying the image is transmitted without the usual diffraction. We present a theoretical model, for the case of a fully spatially-coherent coupling beam, that predicts that the transverse characteristics of the coupling beam are efficiently transferred to the probe beam, in spite of distortions of the control image due to diffraction during propagation. Indeed, the cloned images can be much better than the original images of the coupling beam, with structures reduced in size by approximately a factor of 2. Experimentally, we found that the lower the degree of coherence of the coupling light, the better the cloned image compared to the coupling image for the same propagation distance. A comparison with other cloning techniques studied in the literature, with spatally coherent light, shows that our mechanism has a similar performance, with a maximum cloned image transmission by the atomic vapor of approximately 10% / Doutorado / Física / Doutor em Ciências / 153079/2010 / 0554/15 / CNPQ / Funcamp
2

Avaliação in vitro do efeito do clareamento dental prévio a cimentação de restaurações indiretas / In vitro evaluation of the effect of dental bleaching prior to cementation of indirect restorations

Fogli, Silvia Stuber 05 June 2017 (has links)
O presente trabalho experimental, tem como objetivo avaliar \"in vitro\" possíveis falhas na cimentação de fragmentos cerâmicos sobre substrato de esmalte dentário previamente submetido ao clareamento dental e analisados pelo sistema de tomografia por coerência ótica. O ensaio experimental foi realizado in vitro, fazendo uso de trinta pré-molares superiores humanos. Cada elemento dental teve sua porção de esmalte vestibular aplainada por meio de disco de sílica na granulação 120, foram cimentados fragmentos cerâmicos retangulares de 1.5mm de espessura. Os dentes foram distribuídos aleatoriamente em 3 grupos de 10 dentes cada (n=10), Grupo 1: Fragmentos cimentados sem serem submetidos ao tratamento clareador; Grupo 2: Fragmentos cimentados 24 hrs. Após serem submetidos ao clareamento dental; Grupo 3: Fragmentos cimentados 7 dias após serem submetidos ao clareamento dental. Os espécimes foram transferidos para o sistema de tomografia por coerência óptica para seus respectivos monitoramentos após exposição ao agente clareador e cimentação da restauração indireta e ao final dos ensaios de envelhecimento artificial por termociclagem. A variável de resposta, falhas na interface esmalte e cimento resinoso, foi avaliada por escores (0,1 e 2) que representam em ordem crescente as falhas entre o substrato dental e a restauração indireta. Os valores obtidos foram analisados por meio de testes não paramétricos (Kruskal-Wallis e Wilcoxon). Os resultados constituíram de 60 escores de fendas referentes aos 3 grupos (G1;G2;G3) analisados imediatamente após a cimentação e após a termociclagem. A comparação entre os 3 grupos após termociclagem demonstrou haver diferença estatisticamente significante (p<0,0001) pela comparação dois a dois pelo teste complementar de Dunn e detectou-se que o G2 cimentado após 24 horas do clareamento apresentou mais fendas que G1 e G3. Com base nestes resultados e na metodologia utilizada pode-se concluir que, dentes submetidos ao tratamento clareador, o protocolo clinico de cimentação de restaurações cerâmicas indiretas, quando realizado 7 dias após o clareamento gerou menor quantidade de fendas na interface, propondo assim melhor qualidade na adaptação dente/restauração. / The present experimental study has the objective of evaluating in vitro possible failures in the cementation of ceramic fragments over dental enamel substrate previously submitted to dental bleaching and analyzed by optical coherence tomography system. The experimental trial was performed in vitro using thirty human maxillary premolars. Each dental element had have it\'s portion of vestibular enamel planed by a silic disk in granulation 120, ceramic fragments with a diameter of 1.5mm thickness were cemented. The teeth were randomly distributed in 3 groups of 10 teeth each (n = 10), Group 1: Bonded Veneer without being subjected to bleaching treatment Group 2: Bonded Veneer 24 hours after being submitted to dental bleaching Group 3: Bonded Veneer 7 days after being submitted to dental bleaching. The specimens were transferred to the optical coherence tomography system for their respective monitoring after being exposured to the whitening agent and cementation of the indirect restoration and at the end of the artificial aging tests by thermocycling. The variable of response, at faults in the interface enamel and resin cement, was evaluated by scores (0,1 and 2) that represent in increasing order the failures between dental substrate and indirect restoration. The values obtained were analyzed by non-parametric tests (Kruskal-Wallis and Wilcoxon). The results consisted of 60 gaps scores for the three groups (G1, G2, G3) analyzed immediately after bonding and after thermocycling. The comparison between the 3 groups after thermocycling, showed a statistically significant difference (p <0.0001) by the two-to-two comparison by Dunn\'s complementary test and it was detected that G2 after 24 hours of bleaching, showed more gaps than G1 and G3. Based on these results and the methodology used, it was concluded that, when teeth were submitted to the bleaching treatment, the clinical cementation protocol of indirect ceramic restorations, when performed 7 days after bleaching, generated fewer gaps at the interface, thus proposing a better quality in the relation Tooth / restoration.
3

Avaliação in vitro do efeito do clareamento dental prévio a cimentação de restaurações indiretas / In vitro evaluation of the effect of dental bleaching prior to cementation of indirect restorations

Silvia Stuber Fogli 05 June 2017 (has links)
O presente trabalho experimental, tem como objetivo avaliar \"in vitro\" possíveis falhas na cimentação de fragmentos cerâmicos sobre substrato de esmalte dentário previamente submetido ao clareamento dental e analisados pelo sistema de tomografia por coerência ótica. O ensaio experimental foi realizado in vitro, fazendo uso de trinta pré-molares superiores humanos. Cada elemento dental teve sua porção de esmalte vestibular aplainada por meio de disco de sílica na granulação 120, foram cimentados fragmentos cerâmicos retangulares de 1.5mm de espessura. Os dentes foram distribuídos aleatoriamente em 3 grupos de 10 dentes cada (n=10), Grupo 1: Fragmentos cimentados sem serem submetidos ao tratamento clareador; Grupo 2: Fragmentos cimentados 24 hrs. Após serem submetidos ao clareamento dental; Grupo 3: Fragmentos cimentados 7 dias após serem submetidos ao clareamento dental. Os espécimes foram transferidos para o sistema de tomografia por coerência óptica para seus respectivos monitoramentos após exposição ao agente clareador e cimentação da restauração indireta e ao final dos ensaios de envelhecimento artificial por termociclagem. A variável de resposta, falhas na interface esmalte e cimento resinoso, foi avaliada por escores (0,1 e 2) que representam em ordem crescente as falhas entre o substrato dental e a restauração indireta. Os valores obtidos foram analisados por meio de testes não paramétricos (Kruskal-Wallis e Wilcoxon). Os resultados constituíram de 60 escores de fendas referentes aos 3 grupos (G1;G2;G3) analisados imediatamente após a cimentação e após a termociclagem. A comparação entre os 3 grupos após termociclagem demonstrou haver diferença estatisticamente significante (p<0,0001) pela comparação dois a dois pelo teste complementar de Dunn e detectou-se que o G2 cimentado após 24 horas do clareamento apresentou mais fendas que G1 e G3. Com base nestes resultados e na metodologia utilizada pode-se concluir que, dentes submetidos ao tratamento clareador, o protocolo clinico de cimentação de restaurações cerâmicas indiretas, quando realizado 7 dias após o clareamento gerou menor quantidade de fendas na interface, propondo assim melhor qualidade na adaptação dente/restauração. / The present experimental study has the objective of evaluating in vitro possible failures in the cementation of ceramic fragments over dental enamel substrate previously submitted to dental bleaching and analyzed by optical coherence tomography system. The experimental trial was performed in vitro using thirty human maxillary premolars. Each dental element had have it\'s portion of vestibular enamel planed by a silic disk in granulation 120, ceramic fragments with a diameter of 1.5mm thickness were cemented. The teeth were randomly distributed in 3 groups of 10 teeth each (n = 10), Group 1: Bonded Veneer without being subjected to bleaching treatment Group 2: Bonded Veneer 24 hours after being submitted to dental bleaching Group 3: Bonded Veneer 7 days after being submitted to dental bleaching. The specimens were transferred to the optical coherence tomography system for their respective monitoring after being exposured to the whitening agent and cementation of the indirect restoration and at the end of the artificial aging tests by thermocycling. The variable of response, at faults in the interface enamel and resin cement, was evaluated by scores (0,1 and 2) that represent in increasing order the failures between dental substrate and indirect restoration. The values obtained were analyzed by non-parametric tests (Kruskal-Wallis and Wilcoxon). The results consisted of 60 gaps scores for the three groups (G1, G2, G3) analyzed immediately after bonding and after thermocycling. The comparison between the 3 groups after thermocycling, showed a statistically significant difference (p <0.0001) by the two-to-two comparison by Dunn\'s complementary test and it was detected that G2 after 24 hours of bleaching, showed more gaps than G1 and G3. Based on these results and the methodology used, it was concluded that, when teeth were submitted to the bleaching treatment, the clinical cementation protocol of indirect ceramic restorations, when performed 7 days after bleaching, generated fewer gaps at the interface, thus proposing a better quality in the relation Tooth / restoration.

Page generated in 0.0626 seconds