• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 17
  • 17
  • 13
  • 11
  • 7
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da união cerâmica-vítrea/cimento-resinoso usando diferentes soluções contendo silano = Evaluation of glass-ceramic/resin-cement interface using different silane-containing solutions / Evaluation of glass-ceramic/resin-cement interface using different silane-containing solutions

Murillo Gomez, Fabian de Jesus, 1987- 02 October 2015 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T18:55:47Z (GMT). No. of bitstreams: 1 MurilloGomez_FabiandeJesus_M.pdf: 4403834 bytes, checksum: ae72b6fa87d5cdfc548aeb22600fca46 (MD5) Previous issue date: 2015 / Resumo: O objetivo deste estudo foi avaliar a interação de diferentes soluções contendo silano, com cerâmica vítrea e cimentos resinosos por meio da resistência de união por microcisalhamento e avaliação morfológica da fratura. Este estudo foi separado em dois capítulos. No capítulo 1 foi verificada a influência de quatro soluções contendo silano (solução convencional, solução convencional seguida da aplicação de um sistema adesivo convencional, sistema adesivo universal contendo silano e um primer universal para materiais cerâmicos contendo silano) e a influência do uso ou não do condicionamento prévio da cerâmica com ácido fluorídrico na resistência de união entre uma cerâmica vítrea e um cimento resinoso convencional, após 24h. A análise morfológica da fratura foi avaliada com microscópio eletrônico de varredura. Todos os dados foram submetidos à análise de variância a dois fatores e teste de Tukey (?=0.05). Os resultados mostraram que o condicionamento prévio da cerâmica com ácido fluorídrico foi um fator determinante na obtenção de valores estatisticamente significativos na resistência de união entre ela e o cimento resinoso. A solução de silano convencional foi o único tratamento que proporcionou valores significativamente maiores de resistência de união sem a aplicação do condicionamento prévio na cerâmica vítrea. Todas as soluções proporcionaram resistência de união estatisticamente superior quando o ácido fluorídrico foi usado previamente em relação ao grupo de cerâmicas só jateadas com óxido de alumínio. Os valores foram diferentes estatisticamente entre as soluções, sendo a solução convencional de silano a mais efetiva. Padrão de fratura coesiva no cimento foi associado com valores maiores, enquanto que falha adesiva foi associada com menor resistência de união. No capítulo 2, o objetivo foi avaliar a interação das mesmas soluções contendo silano com cinco cimentos resinosos, três convencionais (Rely X Ultimate, Rely X ARC e Variolink II) e dois autoadesivos (Bifix e Rely X Unicem 2). A resistência de união por microcisalhamento e o tipo de fratura foram avaliados. Os valores foram submetidos à análise estatística a dois fatores e ao teste de Tukey (?=0.05). Os resultados mostraram que a resistência de união foi maior quando a cerâmica foi tratada com a solução convencional de silano para todos os cimentos. A maioria dos cimentos apresentou resistência de união sem diferença estatística quando usados junto com o sistema adesivo universal e o primer cerâmico, exceto para o Bifix e Rely X ARC. Nas fotografias em MEV observaram-se áreas de polimerização incompleta nos casos do Bifix e Rely X ARC. Os grupos com melhor resistência de união apresentaram maior prevalência de fratura coesiva no cimento, enquanto que os grupos com menores valores de resistência de união apresentaram maior prevalência de fraturas adesivas e maior variabilidade do tipo de falha no mesmo grupo. Como conclusão observou-se que as soluções que combinam silano com outros componentes podem melhorar a adesão entre a cerâmica vítrea e o cimento resinoso sempre que utilizadas em cerâmicas vítreas previamente condicionadas, mas o seu efeito positivo é menor do que o obtido pela solução convencional de silano. Além disso, a interação dessas soluções não convencionais com os cimentos resinosos é material dependente já que nem todos os cimentos avaliados foram afetados / Abstract: The aim of this study was to evaluate the interaction of different silane-containing solutions, with glass ceramic and resin cements by performing a µSBS and failure evaluation. This investigation was separated in two chapters. Chapter 1 verified the influence of four silane-containing solutions (conventional solution, conventional solution followed by a conventional adhesive system, silane-containing universal adhesive system and a silane-containing universal ceramic primer) and previous hydrofluoric acid etching on µSBS of glass ceramic and one conventional resin cement after 24 hours storage. Morphological failure analysis was assessed with a scanning electron microscope. All data was submitted to two-way ANOVA and Tukey test (p<0.05). Results showed that hydrofluoric acid etching was determining to increase µSBS. The only solution that increased significantly µSBS mean value without previous hydrofluoric acid etching was the sole-silane solution. All tested solutions increased µSBS when ceramic was previously etched but with statistical differences between them, being the most effective the sole-silane solution. Cohesive failure in resin cement was associated with higher µSBS values, while ceramic/cement adhesive failure was correlated to lower mean values. In chapter 2 the purpose was to evaluate the interaction of the same silane solutions with five resin cements, three conventional (Rely X Ultimate, Rely X ARC e Variolink II) and two self-adhesive (Bifix e Rely X Unicem 2). Also µSBS test and failure evaluation were performed and results analyzed by ANOVA two-way and Tukey test (p<0.05). Results showed that µSBS was higher when ceramic was treated with the sole-silane solution for all cements. Most of cements showed statistically similar mean values when treated with the universal adhesive and the universal ceramic primer with the exception of BiFix and RelyX ARC. SEM images revealed some incomplete polymerization areas for those cases. Likewise groups that performed better showed more prevalence of cohesive failure in resin cement while groups that presented lower mean values showed more prevalence of adhesive failure and more failure type variability. As conclusion, it was observed that solutions combining silane with other components could improve adhesion between glass ceramic and resin cement whenever employed on previously conditioned ceramics, but their positive effect is lower than the one produced by the sole-silane solution. Furthermore, interaction of those non-conventional silane-solutions with resin cements may be material dependent as not all cements tested were negatively affected / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
12

Análise da resistência à fratura de dentes caninos de cães (Canis familiaris) submetidos a restaurações biológicas: experimento in vitro / Fracture strength analysis of canine teeth restored biologically: in vitro>/I> study

Corrêa, Herbert Lima 01 July 2003 (has links)
Para avaliação da resistência à fratura de dentes caninos de cães restaurados biologicamente (colagem de fragmento) foram utilizados 50 dentes distribuídos em cinco grupos de dez dentes cada. Com exceção dos dentes do grupo 1, que serviram de controle, os demais foram seccionados e posteriormente restaurados com o próprio fragmento (colagem) através de diferentes protocolos: Grupo 2: pino fundido (Níquel-Cromo) e cimento resinoso; Grupo 3: pino de fibra de vidro e cimento resinoso; Grupo 4: pino de fibra de carbono e cimento resinoso; Grupo 5: não foram utilizados pinos, apenas adesivo e resina composta fotopolimerizável (colagem simples). Os dentes foram, então, submetidos a teste de resistência através da aplicação de uma carga perpendicular ao longo eixo do dente na sua face lingual. Os resultados permitiram concluir que a utilização de pinos intra-radiculares teve influência significativa na resistência à fratura dos dentes colados quando comparada ao grupo de colagem simples, no entanto, foi de 45,4 %, 14,2%, 11,4% (respectivamente para os grupos 2, 3 e 4) da resistência necessária para fraturar os dentes íntegros, enquanto para o grupo 5 foi de 7,0 %. Dessa forma, nas condições deste experimento, os protocolos nos quais se utilizam pinos intra-radiculares parecem ser os mais indicados para colagem de dentes caninos fraturados. / To determine the fracture strength of canine teeth of dogs restored biologically (bondind of tooth fragment), 50 teeth were used and distributed in 5 groups of ten teeth each. The group 1 was the control (intact teeth). In the other groups the teeth were sectioned and bonded under different protocols: Group 2: cast post (Nickel-chromium) and resin luting cement; Group 3: Fiberglass post and resin luting cement; Group 4: Carbon fiber post and resin luting cement; Group 5: no post was used, only dentin adhesive and light-cured composite resin (simple bonding). The teeth were submitted to fracture strength test through the application of a perpendicular load to the tooth long axis in its lingual face. The results showed that the use of post improved significant fracture strength of bonding teeth when compared to the group of simple bonding, however this was 45.4%, 14.2%, 11.4% (respectively for the groups 2, 3 and 4) of the load necessary to fracture the sound teeth, whereas was it 7.0% in group 5. In these experimental conditions, the protocols where posts are used seem to be more indicated to bonding tooth fragment in fractured canine tooth.
13

Avaliação da reação periodontal na técnica de colagem extra-alveolar de fraturas radiculares verticais simuladas : estudo histológico /

González Hernández, Pedro Antonio. January 2005 (has links)
Orientador: José Roberto Cury Saad / Banca: Adair Luiz Stefanello Busato / Banca: Luiz Alberto Plácido Penna / Banca: Maria Salete Machado Cândido / Banca: Welingtom Dinelli / Resumo: Este estudo teve como objetivo verificar a resposta histológica que ocorre no periodonto de inserção após o reimplante de dentes que foram tratados através da técnica de colagem radicular extra-alveolar. Foram selecionados 16 primeiros pré-molares maxilares e mandibulares de cães (s.r.d), divididos em dois grupos de observação: 21 dias e 90 dias. Sob anestesia geral, os dentes foram extraídos utilizando a técnica primeira de exodontia. Com auxílio de um disco de diamante de dupla face foi realizado um corte longitudinal no sentido ápico-cervical e mésio-distal, simulando uma fratura radicular longitudinal. As superfícies dentinárias e cementárias internas foram condicionadas com o primer do cimento de ionômero de vidro modificado por resinas Vitremer (3M-ESPE). A fenda resultante foi preenchida com cimento de ionômero de vidro modificado por resinas Vitremer (3M-ESPE), numa proporção pó/líquido 1:2, após foi polimerizado o material. Um corte cervical transversal foi realizado e o resultante radicular foi reimplantado. Um retalho tipo Novak-Peter garantiu o sepultamento dentário. Após 21 e 90 dias um novo retalho foi realizado para expor a superfície óssea. Realizou-se uma ostectomia com a finalidade de obter um bloco ósseo-dentário. A loja óssea residual foi protegida com o retalho tipo Novak-Peter. A peça anatômica foi processada histotécnicamente para permitir a observação dos resultados em microscopia óptica. Foram consideradas estatisticamente significativas a identificação de áreas de reabsorção radicular externa inflamatória progressiva no terço médio (aos 90 dias estas se mostravam inativas); a observação dos eventos de reabsorção óssea nos terços alveolares médio e apical (ativas aos 21 dias e inativas aos 90 dias) e a capacidade de cicatrização das fibras do ligamento periodontal, evidente aos 90 dias, principalmente nas regiões...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to verify the histological reply that occurred in supporting periodontal after the reimplant of teeth that had been treated using the technique of extra-alveolar root bonding. Sixteen canine maxilar and mandibular first premolars were selected, divided into two groups of observation: 21 and 90 days. Under general anesthetic, the teeth were extracted utilising forceps technique of exodontics. With the help of doublesided diamond disk, apico-cervical and mesio-distal longitudinal-sections were performed, simulating a longitudinal root fracture. The internal dentin and cementum surfaces were treated with a glass ionomer cement primer modified with resins, Vitremer (3M-ESPE). The resultant gap was filled with glass ionomer cement modified with resins, Vitremer (3M-ESPE), in the proportion powder/liquid 1:2, after which the material was polymerize. A cervic-transversal section was made and the resulting root was reimplanted. A Novak-Peter surgical flap ensured the dental buried. After 21 and 90 days, a new flap was made to expose the bone surface. An osteotomy was undertaken with the purpose of obtaining a dental-bone tissue block. The residual bone lodge was protected with a Novak-Peter surgical flap. The specimens were processed by routine histological technique for light microscope study. Were considered statistically significant: the identification of external root progressive inflammatory resorption areas in the middle third (at 90 days these were shown to be inactive); the observation of external root progressive inflammatory resorption events in medium and apical alveolar third (active at 21 days and inactive at 90 days); and the healing capacity of the periodontal ligament fibers (evident at 90 days) principally in the cervical and medium areas...(Complete abstract, click electronic address below). / Doutor
14

Estudo da resistência às forças de cisalhamento de três sistemas condicionantes indicados para a colagem de acessórios ortodônticos

Bertoz, André Pinheiro de Magalhães [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T20:36:31Z : No. of bitstreams: 1 bertoz_apm_me_araca.pdf: 3969582 bytes, checksum: bceb452a18ac260c5d9321687a89fc4b (MD5) / Os recentes materiais de colagem dos acessórios ortodônticos têm visado reduzir o tempo de trabalho do clínico, simplificando o procedimento do condicionamento ácido por meio dos sistemas adesivos autocondicionantes. Todavia, as qualidades adesivas desses materiais ainda demandam ser avaliada. Assim, o presente estudo objetivou avaliar a resistência às forças de compressão de três sistemas adesivos. Cento e oitenta incisivos inferiores bovinos foram seccionados e incluídos em matrizes de resina acrílica, nos quais acessórios ortodônticos foram colados com os sistemas Transbond XT (2 grupos de 30), Transbond XT Plus Self Etching Primer (2 grupos de 30) e Tyrian (2 grupos de 30). Para cada sistema, os testes de resistência foram realizados imediatamente (30 dentes) e 24 horas (30 dentes) após a colagem, em uma máquina de ensaio Versat 2000 (Pantec), utilizando célula de carga de 500 Kgf com uma velocidade de 1mm/minuto, de acordo com a literatura. Os sistemas convencional Transbond XT, Transbond XT Self Etching Primer e Tyrian apresentaram, respectivamente, valor médio de resistência à compressão de 7,43, 7,09 e 3,41 MPa no tempo imediatamente após a colagem, e 7,42, 8,81, 5,35 MPa no tempo 24 horas após a colagem, sendo as diferenças estatísticas significantes ao nível de 5% entre os grupos Tyrian e Transbond para ambos os tempos de estudo. Concluiu-se que o material Tyrian apresentou resistência à compressão significativamente inferior em relação aos grupos Transbond que foram similares. / Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.
15

Colagem de fragmentos em dentes anteriores fraturados : efeito de materiais e tecnicas na resistencia ao impacto / Reattachment of fragments in fractured anterior teeth : effect of materials and techniques on impact strength

Alonso, Renata Camila Bruschi 14 February 2007 (has links)
Orientador: Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T10:12:27Z (GMT). No. of bitstreams: 1 Alonso_RenataCamilaBruschi_M.pdf: 1462277 bytes, checksum: 2005c106fdedd696c9baa0d0a44fc8ca (MD5) Previous issue date: 2007 / Resumo: O objetivo desse estudo foi avaliar in vitro o efeito de diferentes materiais e técnicas de colagem de fragmentos na resistência ao impacto de dentes anteriores, comparando-a com a resistência à fratura dos dentes hígidos. Para isso, foram selecionados 90 incisivos inferiores bovinos recém-extraídos, com dimensões da coroa de aproximadamente 15 mm de largura mésio-distal e 25 mm de comprimento inciso-cervical. Para a obtenção de fragmentos padronizados, foi realizada secção da coroa de 80 dentes a 12 mm da borda incisal com o uso de disco diamantado em cortadeira Isomet 1000. Remanescentes dentais e fragmentos foram submetidos ao ultrassom em banho de água por 2 horas para remoção da smear layer. Em seguida, os dentes foram embutidos em tubos de PVC com resina acrílica, e o ligamento periodontal foi simulado com poliéter (Impregum Soft). Os dentes seccionados foram distribuídos em 8 grupos (n=10), segundo os materiais e a técnica de colagem de fragmento: G1 - Colagem Direta (CD) + Single Bond (SB) + Filtek Z350 Flow (FF); G2 - CD + Clearfil SE Bond (CSE) + FF; G3 - CD + SB + Rely X CRA (RX); G4 - CD + CSE + RX; G5 - Chanfro Circunferencial (CC) + SB + FF; G6 - CC + CSE + FF; G7 - CC + SB + RX; G8 -CC + CSE + RX. O chanfro circunferencial foi confeccionado após o reposicionamento do fragmento utilizando ponta diamantada esférica (#1016) e, em seguida, restaurado com compósito Filtek Z250 (A3). Todos os materiais foram aplicados de acordo com as instruções dos fabricantes. Dez dentes foram mantidos hígidos para compor o grupo controle. Em seguida, as amostras foram armazenadas em água deionizada a 37oC, durante 24h e submetidas a acabamento e polimento utilizando pontas diamantadas (#3195 F/FF) e sistema Sof-Lex. Para análise da resistência ao impacto, as amostras foram posicionadas em uma máquina universal de testes mecânicos (Instron) de modo que uma carga compressiva foi aplicada na face vestibular a 2 mm do bordo incisal com velocidade de 500 mm/min até a fratura da amostra. Os dados obtidos foram submetidos à Análise de Variância e as médias comparadas pelo teste de Ryan-Einot-Gabriel-Welsch a 5% de significância. Os resultados obtidos, em Kgf, foram, em ordem decrescente: G controle - 64,8; G7 - 43,36; G5 - 37,82; G6 - 37,44; G8 - 26,68; G1 - 26,48; G3 - 23,59; G4 - 17,55; G2 -12,42. A técnica de colagem utilizando Chanfro Circunferencial foi significativamente superior à técnica de Colagem Direta. A utilização do sistema adesivo de condicionamento ácido total Single Bond promoveu aumento significativo na resistência ao impacto quando comparado ao sistema autocondicionante Clearfil SE Bond. Não houve diferença significativa entre os agentes cimentantes Rely X e Filtek Z350 Flow. Nenhuma técnica ou material considerado individualmente foi capaz de devolver ao dente restaurado a resistência mecânica do dente hígido. Somente a associação entre técnica de colagem com Chanfro Circunferencial e sistema de união Single Bond foi capaz de devolver ao dente restaurado a resistência mecânica do dente hígido / Abstract: The objective of this in vitro study was to evaluate the effect of different materials and reattachment techniques on the resistance to impact of anterior teeth and also to compare the resistance to fracture shown by both, sound and restored anterior teeth, considering the different reattachment techniques used. Ninety fresh bovine incisors with crown dimensions of approximately 15 mm of mesiodistal width and 25 mm of incisocervical length were selected. In order to obtain standardized fragments, 80 crowns was sectioned 12 mm from the incisal edge buy means of a diamond saw in an ISOMET 1000 machine. Dental remnants and incisal fragments were submitted to ultrasonic bath for 2 hours, so as to remove smear layer. After the teeth were mounted in PVC rings and embedded in acrylic resin, the periodontal tissue was simulated using polyether (Impregum Soft). The sectioned teeth were distributed in 8 groups (n=10) according to material and reattachment technique: G1 - Direct bonding (DB) + Single Bond (SB) + Filtek Z350 Flow (FF); G2 - DB + Clearfil SE Bond (CSE) + FF; G3 - DB + SB + Rely X CRA (RX); G4 - DB + CSE + RX; G5 - Circumferential Chamfer (CC) + SB + FF; G6 - CC + CSE + FF; G7 - CC + SB + RX; G8 - CC + CSE + RX. The circumferential chamfer was prepared after the bonding of the fragment by means of a spherical diamond point (# 1016). The chamfer was filled with the restorative composite Filtek Z250 (A3). All materials were applied according to the manufacturers' instructions. Ten sound teeth were used as control group. The embedded specimens were stored for 24 hours in deionized water at 37oC and then submitted to finishing and polishing procedures using diamond points (#3195F/FF) and the Sof-Lex system. To evaluate their resistance to impact, the specimens were positioned in a universal testing machine (Instron). A compressive load was applied on the buccal surface, 2 mm from the incisal edge and at a crosshead speed of 500 mm/min, until the failure. The resulting data were submitted to ANOVA One Way and Ryan-Einot-Gabriel-Welsch Multiple Range test at 5% significance. The results (Kgf), were, in decreasing order: G control - 64.8; G7 - 43.36; G5 - 37.82; G6 - 37.44; G8 - 26.68; G1 - 26.48; G3 - 23.59; G4 - 17.55; G2 - 12.42. The fragment reattachment using the circumferential chamfer technique showed results which were significantly better than those shown by direct bonding. In addition, the use of the conventional total-etching bonding system Single Bond caused a significant increase in impact resistance when compared to the use of the self-etching bonding system Clearfil SE Bond. There was no significant difference among the luting agents (Rely X and Filtek Z350 Flow). No technique or material, when individually considered, was capable of achieving the mechanical strength of the sound teeth. Only the association of reattachment technique using circumferential chamfer with the bonding system Single Bond was capable of giving back to the restored teeth the resistance to impact shown by the sound teeth / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
16

Análise da resistência à fratura de dentes caninos de cães (Canis familiaris) submetidos a restaurações biológicas: experimento in vitro / Fracture strength analysis of canine teeth restored biologically: in vitro>/I> study

Herbert Lima Corrêa 01 July 2003 (has links)
Para avaliação da resistência à fratura de dentes caninos de cães restaurados biologicamente (colagem de fragmento) foram utilizados 50 dentes distribuídos em cinco grupos de dez dentes cada. Com exceção dos dentes do grupo 1, que serviram de controle, os demais foram seccionados e posteriormente restaurados com o próprio fragmento (colagem) através de diferentes protocolos: Grupo 2: pino fundido (Níquel-Cromo) e cimento resinoso; Grupo 3: pino de fibra de vidro e cimento resinoso; Grupo 4: pino de fibra de carbono e cimento resinoso; Grupo 5: não foram utilizados pinos, apenas adesivo e resina composta fotopolimerizável (colagem simples). Os dentes foram, então, submetidos a teste de resistência através da aplicação de uma carga perpendicular ao longo eixo do dente na sua face lingual. Os resultados permitiram concluir que a utilização de pinos intra-radiculares teve influência significativa na resistência à fratura dos dentes colados quando comparada ao grupo de colagem simples, no entanto, foi de 45,4 %, 14,2%, 11,4% (respectivamente para os grupos 2, 3 e 4) da resistência necessária para fraturar os dentes íntegros, enquanto para o grupo 5 foi de 7,0 %. Dessa forma, nas condições deste experimento, os protocolos nos quais se utilizam pinos intra-radiculares parecem ser os mais indicados para colagem de dentes caninos fraturados. / To determine the fracture strength of canine teeth of dogs restored biologically (bondind of tooth fragment), 50 teeth were used and distributed in 5 groups of ten teeth each. The group 1 was the control (intact teeth). In the other groups the teeth were sectioned and bonded under different protocols: Group 2: cast post (Nickel-chromium) and resin luting cement; Group 3: Fiberglass post and resin luting cement; Group 4: Carbon fiber post and resin luting cement; Group 5: no post was used, only dentin adhesive and light-cured composite resin (simple bonding). The teeth were submitted to fracture strength test through the application of a perpendicular load to the tooth long axis in its lingual face. The results showed that the use of post improved significant fracture strength of bonding teeth when compared to the group of simple bonding, however this was 45.4%, 14.2%, 11.4% (respectively for the groups 2, 3 and 4) of the load necessary to fracture the sound teeth, whereas was it 7.0% in group 5. In these experimental conditions, the protocols where posts are used seem to be more indicated to bonding tooth fragment in fractured canine tooth.
17

Avaliação in vitro da resistencia ao cisalhamento de braquetes metalicos com e sem composito incorporado a base e cimentos de ionomero de vidro com variação da superficie de esmalte

Ramalli, Edvaldo Luiz 02 April 2005 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:57:14Z (GMT). No. of bitstreams: 1 Ramalli_EdvaldoLuiz_D.pdf: 836688 bytes, checksum: 22c18067abe55c01f713fc62bbe6b0a6 (MD5) Previous issue date: 2005 / Resumo: O propósito deste estudo foi avaliar a resistência ao cisalhamento de braquetes metálicos (Victory Series, 3M Unitek, Monrovia, USA) com e sem compósito incorporado à base (APC II e APC Plus) e com os cimentos de ionômero de vidro modificados por resina (Fuji Ortho LC e Fuji Ortho Band), em diferentes condições de superfície de esmalte bovino. Após a remoção dos braquetes foi analisado o índice de remanescente do adesivo (IRA). Duzentos e quarenta incisivos inferiores permanentes bovinos foram incluídos centralizados em tubos de P.V.C. com resina acrílica ativada quimicamente com a face vestibular perpendicular à base do troquel. Na face vestibular dos dentes foram realizadas profilaxia com pedra-pomes e água por dez segundos, lavagem, secagem e os dentes divididos em dezesseis grupos (n=15): Grupo 1 ¿ condicionamento do esmalte com ácido fosfórico à 37%, lavagem e secagem +Transbond XT primer + APC II; Grupo 2 ¿ condicionamento do esmalte com ácido fosfórico à 37%, lavagem e secagem + esmalte umedecido com água destilada + Transbond XT primer + braquetes APC II; Grupo 3 ¿ esmalte seco + Transbond Plus Self-Etching Primer + braquetes APC II; Grupo 4 ¿ esmalte umedecido com água destilada + Transbond Plus Self-Etching Primer + braquetes APC II; Grupos 5 a 8 ¿ tratamento de superfície semelhante aos grupos 1 a 4, porém a colagem dos braquetes realizada com APC Plus; Grupos 9 a 12 - tratamento de superfície semelhante aos grupos 1 a 4, porém braquetes fixados com cimento de ionômero de vidro Fuji Ortho LC; Grupos 13 a 16; tratamento de superfície semelhante aos grupos 1 a 4, porém fixados com cimento de ionômero de vidro Fuji Ortho Band. Após a fixação, os corpos-de-prova foram armazenados em água destilada a 37oC por 24 horas, seguidos de 500 ciclos térmicos de 5oC e 55oC, com duração de 30 segundos em cada banho. Em seguida, os corpos-de-prova foram submetidos ao ensaio de resistência ao cisalhamento em máquina Instron (Modelo 4411) com velocidade de 0,5 mm/min. Os dados foram submetidos à análise de variância e ao teste de Tukey (5%) e mostraram que independente do tratamento superficial do dente, o APC Plus mostrou valores de resistência ao cisalhamento estatisticamente superiores em relação ao Fuji Ortho LC, APC II e Fuji Ortho Band que apresentou o menor valor. Independente do material de colagem, nenhuma diferença estatística foi observada entre os quatro tratamentos de superfície. Com relação ao IRA, para os materiais APC II, APC Plus e Fuji Ortho LC, não houve influência dos diferentes tratamentos superficiais. No entanto, para o material Fuji Ortho Band, o tratamento com o TPSEP em ambiente seco mostrou maior remanescente do adesivo na estrutura dentária, e, para os tratamentos superficial úmido e seco, os materiais APC Plus e Fuji Ortho LC mostraram os mais altos índices de remanescente do adesivo. Com o TPSEP na condição de ambiente seco, não houve diferença estatística significante entre os materiais. Já com o TPSEP na condição úmido, os materiais APC Plus e Fuji Ortho LC mostraram os mais altos índices de IRA / Abstract: The aim of this study was to evaluate the shear bond strength from orthodontic brackets (Victory Series) bonded with composites (APC II and APC Plus) and resin-modified glass ionomer cements (Fuji Ortho LC and Fuji Ortho Band) applied on bovine enamel surface under different enamel conditions (either dry or moisten with distilled water). The adhesive remnant index (ARI) was evaluated after the bracket removal. Two hundred and forty mandibular incisors were included into PVC tubes with chemically activated acrylic resin leaving the vestibular face of perpendicularly to the botton plane of the tube. The vestibular face of all the teeth were cleared with nonfluoridated pumice and water for 10 seconds, washed 10 seconds, dried for the same time and divided into 16 groups (n = 15): Group 1 ¿ enamel etched with 37% phosphoric acid, washed and dried + Transbond XT primer + APC II; Group 2 ¿ enamel etched with 37% phosphoric acid, washed and dried + enamel moistened with distilled water + Transbond XT primer + APC II; Group 3 ¿ dried enamel + Transbond Plus Self Etching Primer + APC II; Group 4 ¿ enamel moistened with distilled water + Transbond Plus Self Etching Primer + APC II; Groups 5 to 8 ¿ enamel surface treatment similar to those from Groups 1 to 4, but brackets bonded with APC Plus; Groups 9 to 12 ¿ enamel surface treatment similar to those from Groups 1 to 4, but brackets bonded with glass ionomer cement (Fuji Ortho LC); Groups 13 to 16 ¿ enamel surface treatment similar to those from Groups 1 to 4, but brackets bonded with glass ionomer cement (Fuji Ortho Band). After the bonding procedures, all samples were stored in distilled water at 37oC for 24 hours, followed by 500 thermocycle between 5 and 55oC, during 30 seconds. The shear bond strength was performed using an Instron universal testing machine (model 4411) at a crosshead speed of 0.5 mm/min. The values were submitted to ANOVA and Tukey¿s test (5%) and showed that, regardless of the enamel surface treatment, the shear bond strength values concerning the APC Plus were statistically greater than those obtained by using Fuji Ortho LC, APC II or Fuji Ortho Band material. Regardless of the bonding material, it was observed no statistical difference between the four enamel surface treatments. In relation to the adhesive remnant index, no influence was observed for the different treatments using APC II, APC Plus or Fuji Ortho LC material. In relation to the Fuji Ortho Band material, however, the conventional treatment using Transbond Plus Self-Etching Primer (TPSEP) showed a better ARI score for the dental structure than the other treatments. In addition, the conventional treatments using APC Plus and Fuji Ortho LC materials for moistened enamel surface showed the highest ARI scores. Regardless of the material used, the Transbond Plus Self- Etching Primer conventionally used showed no difference. On the other hand, the Transbond Plus Self-Etching Primer used under moistened condition showed the highest ARI scores for both APC Plus and Fuji Ortho LC materials / Doutorado / Ortodontia / Doutor em Ortodontia

Page generated in 0.0613 seconds