• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 173
  • 6
  • 1
  • 1
  • Tagged with
  • 183
  • 110
  • 40
  • 33
  • 32
  • 26
  • 23
  • 17
  • 15
  • 14
  • 13
  • 13
  • 13
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

[en] EMBEDDED OTDR MONITORING SYSTEMS FOR NEXT GENERATION OPTICAL ACCESS NETWORKS / [pt] SISTEMAS INTEGRADOS DE MONITORAMENTO POR OTDR PARA REDES DE ACESSO ÓPTICO DE PRÓXIMA GERAÇÃO

12 December 2017 (has links)
[pt] Para suportar os requisitos das redes móveis de 5a geração (5G), os sistemas de comunicação óptica serão usados nas redes de acesso. Isso ocorre porque a evolução das RAN (Radio Access Networks) incluem a centralização do equipamento mais crítico para implantar pontos de acesso móveis de baixa potência, como DAS (Distributed Antenna Systems) e Small Cells. Os serviços emergentes solicitam a implantação de tecnologias de rádio sobre fibra com ênfase na eficiência de largura de banda, eficiência energética e alta confiabilidade. Neste âmbito, um monitoramento eficiente da camada física é imperativo para a operação dessas redes. O sistema de monitoramento deve fornecer uma localização de falhas em serviço, econômico, centralizado e com impacto mínimo para a transmissão de dados. Esta tese propõe vários sistemas de monitoramento incorporado no transceptor utilizando reflectometria óptica no domínio do tempo. Os sistemas de monitoramento são testados em diferentes sistemas de transmissão de dados e arquiteturas de rede, onde é apresentada uma validação simulada e outras experimentais. / [en] In order to support the requirements for 5th generation mobile networks (5G), optical communication systems will be used in the access part of the network. This is because the evolution of radio access networks includes the centralization of the most critical equipment in order to deploy low power mobile access points, like distributed antenna systems and small cells. The emerging services call for the deployment of radio over fibre technologies with emphasis on bandwidth efficiency, energy efficiency and high reliability. Within this scope, an efficient monitoring of the physical layer would become essential for the operation of these networks. The monitoring system should provide in-service, cost efficient and centralized fault localization with minimum impact on data transmission. This thesis proposes several transceiver-embedded optical time domain reflectometry monitoring systems. The monitoring systems are tested over different data transmission systems and network architectures, where one architecture was simulated and several others experimentally validated.
182

Avaliação sequencial do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina -símile na predição do parto prematuro / Sequential evaluation of the cervix and test for phosphorylated insulin-like growth factor binding protein-1 in the prediction of preterm delivery

Rolnik, Daniel Lorber 06 November 2013 (has links)
INTRODUÇÃO: O antecedente de parto prematuro espontâneo em gestação anterior é considerado o principal e mais importante fator de risco clínico para prematuridade, principal causa de morbidade e mortalidade neonatal. Cerca de 25% das pacientes que tiveram parto prematuro apresentarão recorrência. A prevenção secundária consiste na pesquisa de marcadores de maior risco, com o intuito de instituir medidas terapêuticas apropriadas e de evitar tratamentos desnecessários. A hipótese do presente estudo é a de que existe correlação entre os resultados da avaliação do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina-símile (phIGFBP-1) e que a utilização de ambos em associação possa predizer a ocorrência de parto prematuro com maior sensibilidade. OBJETIVOS: Averiguar a utilidade da medida do comprimento do colo uterino e do teste para phIGFBP-1 na predição do parto prematuro antes de 37 e de 34 semanas, a existência de relação dos testes entre si, o melhor valor de corte da medida do colo em diferentes idades gestacionais e a melhor época de realização de cada um dos exames. MÉTODO: Foram compilados e submetidos a análise secundária os dados de 101 gestantes com antecedente de parto prematuro atendidas no Setor de Baixo Peso Fetal da Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, entre 2003 e 2008. A medida do comprimento cervical e o teste para phIGFBP-1 foram realizados a cada três semanas, entre 24 e 34 semanas de gestação, e comparados com o desfecho de parto prematuro e nascimento com 34 semanas ou menos, e o melhor valor de corte do colo uterino foi estabelecido por meio de curva de características operacionais. RESULTADOS: Das 101 gestações estudadas, 25 (24,8%) terminaram em parto prematuro, das quais 12 (11,9%) ocorreram com 34 semanas ou menos. As idades gestacionais médias de avaliação foram de 24, 27, 30 e 33 semanas, e os valores de corte do colo uterino foram de 22, 21, 20 e 16 mm, respectivamente. A medida do comprimento do colo apresentou maior sensibilidade (cerca de 70%) e foi capaz de predizer o parto prematuro em todas as avaliações. O teste para phIGFBP-1 não foi útil com 24 semanas, porém foi capaz de detectar de forma independente o risco de prematuridade com 27, com 30 e com 33 semanas. Houve associação estatística dos exames entre si, de forma que o comprimento cervical médio foi menor em gestantes com teste positivo para phIGFBP-1. A associação dos exames elevou a sensibilidade e o valor preditivo negativo de forma significativa. CONCLUSÕES: A medida do comprimento do colo pela ultrassonografia transvaginal constitui bom marcador de risco para parto prematuro com 24 semanas, e o teste para phIGFBP-1 é útil após 27 semanas. A associação dos dois exames possui alta sensibilidade e alto valor preditivo negativo em gestantes de alto risco para prematuridade espontânea, e a realização do primeiro com 24 semanas e do segundo com 27 semanas constitui bom modelo preditivo para o parto prematuro / INTRODUCTION: The history of spontaneous preterm birth in a previous pregnancy is considered the main and most important clinical risk factor for preterm birth, the leading cause of neonatal morbidity and mortality. About 25% of these patients will deliver prematurely again. Secondary prevention consists in the search for markers of increased risk, in order to institute appropriate therapeutic actions and to avoid unnecessary treatments. The hypothesis of this study is that there is a correlation between the results of the evaluation of the cervix and the test for phosphorylated insulin-like growth factor binding protein-1 (phIGFBP-1) and that the use of both in combination can predict the occurrence of preterm delivery with higher sensitivity. OBJECTIVES: To investigate the usefulness of the measurement of the cervical length and phIGFBP-1 rapid test in the prediction of preterm birth before 37 and 34 weeks, the existence of a relationship between the tests themselves, the best cutoff value of cervical length measurement at different gestational ages and the best time to carry out each of the exams. METHODS: Data of 101 women with previous preterm birth assisted at the Obstetrical Clinic of the Hospital das Clínicas, Faculty of Medicine, University of São Paulo between 2003 and 2008 were collected and subjected to secondary analysis. The measurement of cervical length and the phIGFBP-1 test were performed every three weeks, between 24 and 34 weeks gestation, and compared with the outcome of premature birth before 37 and 34 weeks, and the best cutoff value of the cervix was determined by receiver operator characteristic curves. RESULTS: Of the 101 pregnancies studied, 25 (24.8%) ended in preterm birth, of which 12 (11.9%) occurred at 34 weeks or less. The mean gestational age in each evaluation was 24, 27, 30 and 33 weeks, and the cutoff of the cervix were 22, 21, 20 and 16 millimeters, respectively. The measurement of cervical length showed the highest sensitivity (approximately 70%) and was able to predict preterm birth in all evaluations. The phIGFBP-1 test was not useful at 24 weeks, but was able to independently detect the risk of prematurity at 27, 30 and 33 weeks. Statistical association between the exams was observed, so that the mean cervical length was lower in pregnant women testing positive for phIGFBP-1. The combination of both tests significantly increased the sensitivity and negative predictive value. CONCLUSIONS: The measurement of cervical length by transvaginal ultrasound is a good marker of risk for preterm delivery at 24 weeks, and the test for phIGFBP-1 is useful after 27 weeks. The association of the two tests is valuable and shows high sensitivity and high negative predictive value in women at high risk for spontaneous preterm birth, when the first is preformed with 24 weeks, and the second with 27 weeks
183

Avaliação sequencial do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina -símile na predição do parto prematuro / Sequential evaluation of the cervix and test for phosphorylated insulin-like growth factor binding protein-1 in the prediction of preterm delivery

Daniel Lorber Rolnik 06 November 2013 (has links)
INTRODUÇÃO: O antecedente de parto prematuro espontâneo em gestação anterior é considerado o principal e mais importante fator de risco clínico para prematuridade, principal causa de morbidade e mortalidade neonatal. Cerca de 25% das pacientes que tiveram parto prematuro apresentarão recorrência. A prevenção secundária consiste na pesquisa de marcadores de maior risco, com o intuito de instituir medidas terapêuticas apropriadas e de evitar tratamentos desnecessários. A hipótese do presente estudo é a de que existe correlação entre os resultados da avaliação do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina-símile (phIGFBP-1) e que a utilização de ambos em associação possa predizer a ocorrência de parto prematuro com maior sensibilidade. OBJETIVOS: Averiguar a utilidade da medida do comprimento do colo uterino e do teste para phIGFBP-1 na predição do parto prematuro antes de 37 e de 34 semanas, a existência de relação dos testes entre si, o melhor valor de corte da medida do colo em diferentes idades gestacionais e a melhor época de realização de cada um dos exames. MÉTODO: Foram compilados e submetidos a análise secundária os dados de 101 gestantes com antecedente de parto prematuro atendidas no Setor de Baixo Peso Fetal da Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, entre 2003 e 2008. A medida do comprimento cervical e o teste para phIGFBP-1 foram realizados a cada três semanas, entre 24 e 34 semanas de gestação, e comparados com o desfecho de parto prematuro e nascimento com 34 semanas ou menos, e o melhor valor de corte do colo uterino foi estabelecido por meio de curva de características operacionais. RESULTADOS: Das 101 gestações estudadas, 25 (24,8%) terminaram em parto prematuro, das quais 12 (11,9%) ocorreram com 34 semanas ou menos. As idades gestacionais médias de avaliação foram de 24, 27, 30 e 33 semanas, e os valores de corte do colo uterino foram de 22, 21, 20 e 16 mm, respectivamente. A medida do comprimento do colo apresentou maior sensibilidade (cerca de 70%) e foi capaz de predizer o parto prematuro em todas as avaliações. O teste para phIGFBP-1 não foi útil com 24 semanas, porém foi capaz de detectar de forma independente o risco de prematuridade com 27, com 30 e com 33 semanas. Houve associação estatística dos exames entre si, de forma que o comprimento cervical médio foi menor em gestantes com teste positivo para phIGFBP-1. A associação dos exames elevou a sensibilidade e o valor preditivo negativo de forma significativa. CONCLUSÕES: A medida do comprimento do colo pela ultrassonografia transvaginal constitui bom marcador de risco para parto prematuro com 24 semanas, e o teste para phIGFBP-1 é útil após 27 semanas. A associação dos dois exames possui alta sensibilidade e alto valor preditivo negativo em gestantes de alto risco para prematuridade espontânea, e a realização do primeiro com 24 semanas e do segundo com 27 semanas constitui bom modelo preditivo para o parto prematuro / INTRODUCTION: The history of spontaneous preterm birth in a previous pregnancy is considered the main and most important clinical risk factor for preterm birth, the leading cause of neonatal morbidity and mortality. About 25% of these patients will deliver prematurely again. Secondary prevention consists in the search for markers of increased risk, in order to institute appropriate therapeutic actions and to avoid unnecessary treatments. The hypothesis of this study is that there is a correlation between the results of the evaluation of the cervix and the test for phosphorylated insulin-like growth factor binding protein-1 (phIGFBP-1) and that the use of both in combination can predict the occurrence of preterm delivery with higher sensitivity. OBJECTIVES: To investigate the usefulness of the measurement of the cervical length and phIGFBP-1 rapid test in the prediction of preterm birth before 37 and 34 weeks, the existence of a relationship between the tests themselves, the best cutoff value of cervical length measurement at different gestational ages and the best time to carry out each of the exams. METHODS: Data of 101 women with previous preterm birth assisted at the Obstetrical Clinic of the Hospital das Clínicas, Faculty of Medicine, University of São Paulo between 2003 and 2008 were collected and subjected to secondary analysis. The measurement of cervical length and the phIGFBP-1 test were performed every three weeks, between 24 and 34 weeks gestation, and compared with the outcome of premature birth before 37 and 34 weeks, and the best cutoff value of the cervix was determined by receiver operator characteristic curves. RESULTS: Of the 101 pregnancies studied, 25 (24.8%) ended in preterm birth, of which 12 (11.9%) occurred at 34 weeks or less. The mean gestational age in each evaluation was 24, 27, 30 and 33 weeks, and the cutoff of the cervix were 22, 21, 20 and 16 millimeters, respectively. The measurement of cervical length showed the highest sensitivity (approximately 70%) and was able to predict preterm birth in all evaluations. The phIGFBP-1 test was not useful at 24 weeks, but was able to independently detect the risk of prematurity at 27, 30 and 33 weeks. Statistical association between the exams was observed, so that the mean cervical length was lower in pregnant women testing positive for phIGFBP-1. The combination of both tests significantly increased the sensitivity and negative predictive value. CONCLUSIONS: The measurement of cervical length by transvaginal ultrasound is a good marker of risk for preterm delivery at 24 weeks, and the test for phIGFBP-1 is useful after 27 weeks. The association of the two tests is valuable and shows high sensitivity and high negative predictive value in women at high risk for spontaneous preterm birth, when the first is preformed with 24 weeks, and the second with 27 weeks

Page generated in 0.0512 seconds