Spelling suggestions: "subject:"concrete floor"" "subject:"aconcrete floor""
1 |
Robustness of steel framed buildings with pre-cast concrete floor slabsMiratashi Yazdi, Seyed Mansoor January 2014 (has links)
Following some incidents in high-rise buildings, such as Ronan Point London 1968, in which collapse of a limited number of structural elements progressed to a failure disproportionate to the initial cause, consideration of robustness was introduced in British Standard. The main method of preventing progressive collapse for providing robustness to steel framed buildings with precast concrete floor slabs focuses on the allowable tying forces that the reinforcement in between the slabs and in hollowcores should carry. However there are uncertainties about the basis of the practical rules associated with this method. This thesis presents the results of numerical and analytical studies of tie connection behaviour between precast concrete floor slabs (PCFS). It is shown that under current design regulations the tie connection is not able to resist the accidental load limit applied on the damaged floor slabs. By establishing the capability of a finite element model to depict and predict the behaviour of concrete members in situations such as arching and catenary action against several experimental tests, an extensive set of parametric studies was conducted in order to identify the effective parameters in enhancing the resistance of the tie connection between PCFSs. These parameters include: tie bar diameter, position, length, yield stress and ultimate strain; the slab’s height, length; and the compressive strength of the grouting concrete in between the slabs that encases the tie bar. Recommendations are made based on the findings of this parametric study in order to increase the resistance of the tie connection. Based on the identified effective parameters in the parametric study a predictive analytical relationship is derived which is capable of determining the maximum vertical displacement and load that the tie connection is able to undergo. This relationship can be used to enable the connection to capture the accidental limit load on a damaged slab. The identified parameters are examined in a three dimensional finite element model to assess their effect when columns of the structure are lost in different locations such as an edge, corner or internal column. Based on the findings of this study methods for improving the connections performance are presented. Also the effect of alternative transverse tying method is evaluated and it is concluded that although this kind of tie increases the load carrying capacity of the connection, its effect on the catenary action is not significant.
|
2 |
Knihovna / LibraryBošková, Katarína January 2020 (has links)
This diploma thesis is processed in the form of design documentation for implementation of building. Solved building is a library in Veselí nad Moravou, cadastre unit Veselí-Předměstí. Building includes three above-ground floors and one underground floor. Floor plan is in shape of rectangular. Beside regular departments of library, study rooms, conference room and office parts, there is also a cafe and a bookstore. The structural system of a building is designed from cast-in-place concrete frame with filling from ceramic blocks Porotherm 30 Profi. Horizontal structural system is from cast-in-place reinforced concrete point-supported slabs. Part of facade is from glass and part is with contact thermal insulation system with mineral wool insulation. Roof construction is designed as flat green roof.
|
3 |
Influência do consumo de água, do teor de adição de microfibras de polipropileno, e do tipo de cimento no fenômeno da retração por secagem em concretos empregados em pisos / Influence of water consumption, the addition content of polypropylene staple fibers and the kind of cement in the volumetric changes of concretes used in floorsSenisse, Juliana Alves de Lima January 2010 (has links)
Mudanças volumétricas presentes na matriz cimentícia, oriundas dos processos de hidratação e de secagem do compósito cimentício, geram uma tendência de fissuração no material. Em pisos de concreto, a presença de tal manifestação patológica, decorrente do fenômeno da retração por secagem, é extremamente preocupante. Desta forma, a realização de esforços visando avaliar a influência de materiais constituintes do traço do concreto e seus proporcionamentos, com o intuito de reduzir a tendência de fissuração do material, gerada pelo fenômeno da retração por secagem, é extremamente válida. Para isto, foram avaliados fatores controláveis como o consumo de água (175l/m³; 190l/m³; 205l/m³), o teor de adição de microfibras de polipropileno (0g/m³; 300g/m³; 600g/m³; 900g/m³), o tipo de cimento (CP IV; CP V-ARI) e a idade, variável para cada ensaio realizado. Os ensaios empregados para esta avaliação foram o de resistência à compressão uniaxial, resistência à tração na flexão, retração por secagem livre e retração por secagem restringida. Os resultados dos ensaios mecânicos demonstraram a influência significativa do tipo de cimento e da idade avaliada na resistência do concreto. O teor de adição de microfibras de polipropileno exerceu uma pequena influência, porém significativa, com incrementos de 5% nos resultados mecânicos do ensaio de resistência à compressão uniaxial para os traços com teores de adição de 300g/m³ e 600g/m³. No entanto para o ensaio de resistência à tração na flexão, tal variável não se demonstrou significativa. O fator consumo de água não influenciou significativamente nos resultados correspondentes aos ensaios mecânicos, uma vez que a relação a/c manteve-se constante para todos os concretos estudados. No ensaio de retração por secagem livre, o tipo de cimento não demonstrou significância relevante para os resultados obtidos. Comportamento este, também observado para o teor de adição de microfibras de polipropileno, o qual não reduziu a magnitude da retração por secagem livre. Diferentemente do observado para a variável consumo de água, a qual influenciou significativamente nos dados obtidos, demonstrando a existência de uma relação direta entre a mesma e o fenômeno estudado. No ensaio de retração por secagem restringida, a tendência de fissuração dos concretos estudados foi influenciada significativamente pelo consumo de água presente na mistura. Conjuntamente, os resultados obtidos neste ensaio demonstraram que o teor de adição de microfibras de polipropileno é uma variável que deve ser proporcionada como os demais materiais constituintes do traço do concreto, ou seja, a quantidade incorporada no compósito cimentício não pode ser um valor determinado, semelhante para qualquer tipo de concreto. / Volumetric changes present in the cement paste matrix, coming from the processes of hydration and drying of cementitious composites, generate a cracking tendency in the material. In the concrete floor, this cracking tendency is extremely worrying. In this sense, efforts to evaluate the influence of important parameters in the mixture proportions of concrete, for decrease the cracking tendency due to drying shrinkage, it’s extremely valid. So, parameters were assessed like the consumption of water (175l/m³; 190l/m³; 205l/m³), the addition content of polypropylene staple fiber (0g/m³; 300g/m³; 600g/m³; 900g/m³), the type of cement (CP IV; CP V-ARI) and age, different for each test performed. The tests performed for this assessment were the compressive strength, flexural tensile strength, unrestrained drying shrinkage and restrained drying shrinkage. The results of mechanical tests shown the significant influence of the kind of cement and age assessed in the strength of concrete. The addition content of polypropylene staple fiber exerted little influence on the results of mechanical tests, but it was significant, with increases of 5% in the results of compressive strength for the mixtures with addition levels of 300g/m³ e 600g/m³. However for the flexural tensile strength, this parameter didn’t show significant. The water consumption didn’t influence significantly the results of mechanical tests, since the ratio a/c was constant for all concretes studied. In the unrestrained drying shrinkage, the kind of cement didn’t show importance for the results. This behavior also observed for the addition content of polypropylene staple fiber, which didn’t reduce the magnitude of free drying shrinkage. However, the water consumption influenced significantly in the results, demonstrating the existence of a direct relationship between it and the phenomenon studied. In the restrained drying shrinkage, the cracking tendency of the concrete studied was significantly affected by the consumption of water present in the mixture. Together, the results of this test showed that the addition content of polypropylene staple fiber is a parameter that should be provided as the others materials of the concrete mixture, i.e., the amount of polypropylene staple fiber incorporated into the cementitious composite can’t be a value fixed, similar to any type of concrete mixture.
|
4 |
Influência do consumo de água, do teor de adição de microfibras de polipropileno, e do tipo de cimento no fenômeno da retração por secagem em concretos empregados em pisos / Influence of water consumption, the addition content of polypropylene staple fibers and the kind of cement in the volumetric changes of concretes used in floorsSenisse, Juliana Alves de Lima January 2010 (has links)
Mudanças volumétricas presentes na matriz cimentícia, oriundas dos processos de hidratação e de secagem do compósito cimentício, geram uma tendência de fissuração no material. Em pisos de concreto, a presença de tal manifestação patológica, decorrente do fenômeno da retração por secagem, é extremamente preocupante. Desta forma, a realização de esforços visando avaliar a influência de materiais constituintes do traço do concreto e seus proporcionamentos, com o intuito de reduzir a tendência de fissuração do material, gerada pelo fenômeno da retração por secagem, é extremamente válida. Para isto, foram avaliados fatores controláveis como o consumo de água (175l/m³; 190l/m³; 205l/m³), o teor de adição de microfibras de polipropileno (0g/m³; 300g/m³; 600g/m³; 900g/m³), o tipo de cimento (CP IV; CP V-ARI) e a idade, variável para cada ensaio realizado. Os ensaios empregados para esta avaliação foram o de resistência à compressão uniaxial, resistência à tração na flexão, retração por secagem livre e retração por secagem restringida. Os resultados dos ensaios mecânicos demonstraram a influência significativa do tipo de cimento e da idade avaliada na resistência do concreto. O teor de adição de microfibras de polipropileno exerceu uma pequena influência, porém significativa, com incrementos de 5% nos resultados mecânicos do ensaio de resistência à compressão uniaxial para os traços com teores de adição de 300g/m³ e 600g/m³. No entanto para o ensaio de resistência à tração na flexão, tal variável não se demonstrou significativa. O fator consumo de água não influenciou significativamente nos resultados correspondentes aos ensaios mecânicos, uma vez que a relação a/c manteve-se constante para todos os concretos estudados. No ensaio de retração por secagem livre, o tipo de cimento não demonstrou significância relevante para os resultados obtidos. Comportamento este, também observado para o teor de adição de microfibras de polipropileno, o qual não reduziu a magnitude da retração por secagem livre. Diferentemente do observado para a variável consumo de água, a qual influenciou significativamente nos dados obtidos, demonstrando a existência de uma relação direta entre a mesma e o fenômeno estudado. No ensaio de retração por secagem restringida, a tendência de fissuração dos concretos estudados foi influenciada significativamente pelo consumo de água presente na mistura. Conjuntamente, os resultados obtidos neste ensaio demonstraram que o teor de adição de microfibras de polipropileno é uma variável que deve ser proporcionada como os demais materiais constituintes do traço do concreto, ou seja, a quantidade incorporada no compósito cimentício não pode ser um valor determinado, semelhante para qualquer tipo de concreto. / Volumetric changes present in the cement paste matrix, coming from the processes of hydration and drying of cementitious composites, generate a cracking tendency in the material. In the concrete floor, this cracking tendency is extremely worrying. In this sense, efforts to evaluate the influence of important parameters in the mixture proportions of concrete, for decrease the cracking tendency due to drying shrinkage, it’s extremely valid. So, parameters were assessed like the consumption of water (175l/m³; 190l/m³; 205l/m³), the addition content of polypropylene staple fiber (0g/m³; 300g/m³; 600g/m³; 900g/m³), the type of cement (CP IV; CP V-ARI) and age, different for each test performed. The tests performed for this assessment were the compressive strength, flexural tensile strength, unrestrained drying shrinkage and restrained drying shrinkage. The results of mechanical tests shown the significant influence of the kind of cement and age assessed in the strength of concrete. The addition content of polypropylene staple fiber exerted little influence on the results of mechanical tests, but it was significant, with increases of 5% in the results of compressive strength for the mixtures with addition levels of 300g/m³ e 600g/m³. However for the flexural tensile strength, this parameter didn’t show significant. The water consumption didn’t influence significantly the results of mechanical tests, since the ratio a/c was constant for all concretes studied. In the unrestrained drying shrinkage, the kind of cement didn’t show importance for the results. This behavior also observed for the addition content of polypropylene staple fiber, which didn’t reduce the magnitude of free drying shrinkage. However, the water consumption influenced significantly in the results, demonstrating the existence of a direct relationship between it and the phenomenon studied. In the restrained drying shrinkage, the cracking tendency of the concrete studied was significantly affected by the consumption of water present in the mixture. Together, the results of this test showed that the addition content of polypropylene staple fiber is a parameter that should be provided as the others materials of the concrete mixture, i.e., the amount of polypropylene staple fiber incorporated into the cementitious composite can’t be a value fixed, similar to any type of concrete mixture.
|
5 |
Influência do consumo de água, do teor de adição de microfibras de polipropileno, e do tipo de cimento no fenômeno da retração por secagem em concretos empregados em pisos / Influence of water consumption, the addition content of polypropylene staple fibers and the kind of cement in the volumetric changes of concretes used in floorsSenisse, Juliana Alves de Lima January 2010 (has links)
Mudanças volumétricas presentes na matriz cimentícia, oriundas dos processos de hidratação e de secagem do compósito cimentício, geram uma tendência de fissuração no material. Em pisos de concreto, a presença de tal manifestação patológica, decorrente do fenômeno da retração por secagem, é extremamente preocupante. Desta forma, a realização de esforços visando avaliar a influência de materiais constituintes do traço do concreto e seus proporcionamentos, com o intuito de reduzir a tendência de fissuração do material, gerada pelo fenômeno da retração por secagem, é extremamente válida. Para isto, foram avaliados fatores controláveis como o consumo de água (175l/m³; 190l/m³; 205l/m³), o teor de adição de microfibras de polipropileno (0g/m³; 300g/m³; 600g/m³; 900g/m³), o tipo de cimento (CP IV; CP V-ARI) e a idade, variável para cada ensaio realizado. Os ensaios empregados para esta avaliação foram o de resistência à compressão uniaxial, resistência à tração na flexão, retração por secagem livre e retração por secagem restringida. Os resultados dos ensaios mecânicos demonstraram a influência significativa do tipo de cimento e da idade avaliada na resistência do concreto. O teor de adição de microfibras de polipropileno exerceu uma pequena influência, porém significativa, com incrementos de 5% nos resultados mecânicos do ensaio de resistência à compressão uniaxial para os traços com teores de adição de 300g/m³ e 600g/m³. No entanto para o ensaio de resistência à tração na flexão, tal variável não se demonstrou significativa. O fator consumo de água não influenciou significativamente nos resultados correspondentes aos ensaios mecânicos, uma vez que a relação a/c manteve-se constante para todos os concretos estudados. No ensaio de retração por secagem livre, o tipo de cimento não demonstrou significância relevante para os resultados obtidos. Comportamento este, também observado para o teor de adição de microfibras de polipropileno, o qual não reduziu a magnitude da retração por secagem livre. Diferentemente do observado para a variável consumo de água, a qual influenciou significativamente nos dados obtidos, demonstrando a existência de uma relação direta entre a mesma e o fenômeno estudado. No ensaio de retração por secagem restringida, a tendência de fissuração dos concretos estudados foi influenciada significativamente pelo consumo de água presente na mistura. Conjuntamente, os resultados obtidos neste ensaio demonstraram que o teor de adição de microfibras de polipropileno é uma variável que deve ser proporcionada como os demais materiais constituintes do traço do concreto, ou seja, a quantidade incorporada no compósito cimentício não pode ser um valor determinado, semelhante para qualquer tipo de concreto. / Volumetric changes present in the cement paste matrix, coming from the processes of hydration and drying of cementitious composites, generate a cracking tendency in the material. In the concrete floor, this cracking tendency is extremely worrying. In this sense, efforts to evaluate the influence of important parameters in the mixture proportions of concrete, for decrease the cracking tendency due to drying shrinkage, it’s extremely valid. So, parameters were assessed like the consumption of water (175l/m³; 190l/m³; 205l/m³), the addition content of polypropylene staple fiber (0g/m³; 300g/m³; 600g/m³; 900g/m³), the type of cement (CP IV; CP V-ARI) and age, different for each test performed. The tests performed for this assessment were the compressive strength, flexural tensile strength, unrestrained drying shrinkage and restrained drying shrinkage. The results of mechanical tests shown the significant influence of the kind of cement and age assessed in the strength of concrete. The addition content of polypropylene staple fiber exerted little influence on the results of mechanical tests, but it was significant, with increases of 5% in the results of compressive strength for the mixtures with addition levels of 300g/m³ e 600g/m³. However for the flexural tensile strength, this parameter didn’t show significant. The water consumption didn’t influence significantly the results of mechanical tests, since the ratio a/c was constant for all concretes studied. In the unrestrained drying shrinkage, the kind of cement didn’t show importance for the results. This behavior also observed for the addition content of polypropylene staple fiber, which didn’t reduce the magnitude of free drying shrinkage. However, the water consumption influenced significantly in the results, demonstrating the existence of a direct relationship between it and the phenomenon studied. In the restrained drying shrinkage, the cracking tendency of the concrete studied was significantly affected by the consumption of water present in the mixture. Together, the results of this test showed that the addition content of polypropylene staple fiber is a parameter that should be provided as the others materials of the concrete mixture, i.e., the amount of polypropylene staple fiber incorporated into the cementitious composite can’t be a value fixed, similar to any type of concrete mixture.
|
6 |
Knihovna / LibraryDlouhá, Jana January 2020 (has links)
This diploma thesis deals with design and elaboration of project documentation of library. The building is located on plot No. 6167/2 in Žďár nad Sázavou, number of cadastre unit 795232. The library have three above-ground floor and basement. Irregularly-shaped floor plan of the library is in the shape of the letter "K". In addition to the individual departments of the library, there are study rooms, a multifunctional hall, an information center and a café. Structural system is designed as a cast-in-place concrete frame with a ceramic blocks infill. Horizontal structures are made of cast-in-place reinforced slab. Building has ventilated facade with mineral wool insulation. Roofs constructions are designed as flat green roofs.
|
7 |
Hasičská stanice / Fire stationHorváthová, Radka January 2022 (has links)
The topic of the diploma thesis is the elaboration of project documentation for the construction of a fire station with almost zero energy consumption. The building will serve as a fire station type P4 with the scope of the JPO I unit - a unit of the fire department with a territorial scope, usually within 20 minutes drive from the place of deployment. The designed building is a detached object with two above-ground and one underground floor. The building is designed as a reinforced concrete skeleton. It consists of two operating units. The administrative and operational part has three floors. In this part, the main entrance to the building is on the 1st floor, oriented on the south side. The technical rooms of the fire department are located on the first floor and are functionally connected to the administrative part. Exit garages, a car wash and a dryer are also attached to it. Prior to the elaboration of the project, a visit to the regional fire station in Trnava and a consultation with the director of this station took place regarding the needs and requirements of the fire department.
|
8 |
Ubytovací zařízení / AccommodationGrbálová, Lucia January 2022 (has links)
The subject of the master’s thesis is elaboration of the complete project design documentation of accommodation. The object is designed as a double-star boarding house with stables and a caretaker's flat. It is situated in the village Pružina-Chmelisko, on recreation grounds. The object of the boarding house is divided into three above-ground floors and one underground floor. The roof structure is designed as a gable roof. The stables are single-storey buildings with partially used attic above the caretaker’s flat. The roof structure is gabbled. The carrier system of the boarding house consists of clay blocks and a monolithic, reinforced concrete floor slab. The stables’ carrier system is designed as a wooden joist floor, ceramic fittings are slated for filling. Within specialization is the solution of fire safety assessment of both buildings, thermal technical assessment, assessment of acoustics and lighting of the boarding house.
|
9 |
Penzion / Boarding HouseBalážová, Pavla January 2019 (has links)
The subject of this diploma thesis is a project for design documentation of boarding house which is oriented at south Moravia in the village Pavlov. The object is solved as four-storey with a partial recession of the first floor into the terrain. Boarding house will serve for the accommodation of 52 people. In the first floor, there is an entrance hall with reception, relaxing area and technical equipment of the building. In the second floor, there is a restaurant with a terrace and all necessary facilities for guests and restaurant staff. Two second highest floors are determined for guest accommodation. The construction of foundation is made from strip foundation. The structure is from bricks with monolith reinforced concrete frame in the first floor. It is a longitudinal wall system transversally reinforced by staircases. The perimeter walls will be insulated with ETICS system. The ceiling will be created from the prestressed reinforced concrete panels. Construction of roof is made from truss girders saddle type.
|
10 |
Penzion / Boarding housePálka, Tomáš January 2020 (has links)
The subject of the thesis is a project for the implementation of the construction of the Pension with restaurant and wellness, located in South Moravia in the village Zaječí. The building is designed as a two-storey basement with partial embedding of the first underground floor into the ground. The guesthouse will be used for temporary accommodation of 24 persons. On the first floor there is an entrance hall with reception, facilities for staff and accommodation rooms. The other rooms are located on the second floor. In the basement is a restaurant and wellness, as well as technical facilities. The building is based on the foundation passports. Constructionally o brick building from ceramic blocks. It is a longitudinal wall system transverse stiffened by walls. External walls will be insulated by contact insulation system ETICS. Ceilings will be created from prestressed ceiling panels. The roofing is designed using a saddle roof truss.
|
Page generated in 0.0594 seconds