Corrosion Propagation of Rebar Embedded in High Performance ConcreteUnknown Date (has links)
The FDOT has been using supplementary cementitious materials while constructing steel reinforced concrete marine bridge structures for over 3 decades. Previous findings indicated that such additions in concrete mix makes the concrete more durable. To better understand corrosion propagation of rebar in high performance concrete: mature concrete samples that were made (2008/2009) with Portland cement, a binary mix, a ternary mix and recently prepared (April 2016 with 50% OPC + 50% slag and 80% OPC + 20% Fly ash) concrete samples were considered. None of these concretes had any admixed chloride to start with. An accelerated chloride transport process was used to drive chloride ions into the concrete so that chlorides reach and exceed thechloride threshold at the rebar surface and initiate corrosion. Electrochemical measurements were taken at regular intervals (during and after the electro-migration process) to observe the corrosion propagation in each sample. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2017. / FAU Electronic Theses and Dissertations Collection
|
2 |
Corrosion initiation and propagation on corrosion resistant alloys embedded in concrete by accelerated chloride transportUnknown Date (has links)
Two duplex stainless steels rebars: UNS32304SS and UNS32101SS, were selected to investigate the corrosion initiation and propagation in reinforced concrete specimens. The investigation is divided in two phases with two different methods to accelerate the transport of chlorides through the concrete and initiate corrosion in a short period of time. After corrosion had initiated and propagated for some time; selected specimens were terminated for visual examination. On specimens selected for autopsy, the rebars in the top row showed corrosion to various degrees. Corrosion had propagated to such extent on the terminated specimens that the specimen showed cracks. Stray current might have caused accelerated corrosion on rebars where corrosion had initiated. Based on chloride concentrations measured at the rebar trace, corrosion initiated: on S32101 rebars on average at 7.9 kg/m3, and S32101 rebars on average at 6.0 kg/m3. The findings suggest that S32304 rebars corroded at a slower than S32101. / by Francisco Gutierrez Tellez. / Thesis (M.S.C.S.)--Florida Atlantic University, 2013. / Includes bibliography. / Mode of access: World Wide Web. / System requirements: Adobe Reader.
|
3 |
Centrally prestressed fiber reinforced concrete columnsUnknown Date (has links)
With the need to improve corrosion resistance in columns and piles, the innovative idea of Centrally Prestressed Fiber Reinforced Concrete (CPFRC) columns is a promising solution. The first step is to compare if the compressive strength of any mix is affected by the size, geometry, or even the inclusion of polyolefin fibers in a specimen. The results showed that the cylinder size of 4 in. x 8 in., which is the most common size used by the testing labs, has the highest compressive strength. There was no sign on compressive strength improvement with the use of polyolefin fibers, except for reduction in cracking size and concrete spalling. The second step compared the ultimate strength, ductility characteristics and failure mode of CPFRC columns to conventional columns. CPFRC showed adequate axial and flexural resistance, in addition to ductile behavior similar to regular reinforced concrete columns. / by Daniel A. Grijalba. / Thesis (M.S.C.S.)--Florida Atlantic University, 2011. / Includes bibliography. / Electronic reproduction. Boca Raton, Fla., 2011. Mode of access: World Wide Web.
|
4 |
Chloride penetration into concrete structures exposed to the marine atmosphereUnknown Date (has links)
Chloride ions present in the marine atmosphere contained in marine aerosols is
investigated for a relationship with chloride that accumulated into concrete. Chloride
profiles are conducted on several concrete mixes containing fly ash, silica fume, and slag,
with water to cementitious ratios of 0.35, 0.41, and 0.47. The chloride accumulation in
concrete samples exposed to the environment is investigated with relation to the chloride
deposition from the marine atmosphere measured via the wet candle test. Results indicate
a possible relationship for the total accumulated chloride in the concrete with the
accumulated chloride deposition (wet candle). Over the exposure periods, concrete
specimens with 50% slag addition and 0.47 w/cm had the lowest average rates of chloride
accumulation for deposition under 100 g/m2day. Chloride accumulation was lower in
concrete containing 20% fly ash and 8% silica fume with 0.35 w/cm for chloride deposition
rates over 200 g/m2day. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2014. / FAU Electronic Theses and Dissertations Collection
|
5 |
Initiation and propagation of corrosion in dry-cast reinforced concrete ring specimensUnknown Date (has links)
The corrosion propagation stage of D-CRP (types F and C) was tested under
immersion in water, high humidity, and covered with wet sand. The half-cell potential,
linear polarization test, and electrochemical impedance spectroscopy measurements were
performed. Selected specimens were terminated after 300 days of exposure and visually
inspected. Based on corrosion potential measurements obtained during the corrosion
propagation observation, and calculated corrosion rate based on LPR measurements: all
specimens were actively corroding. Additionally, EIS-Rc values were calculated for FS,
CS and CH specimens. The Rc_EIS were generally greater than Rc_LPR values. EIS
spectra for CI and FI specimens usually included mass transport limitations, as these
specimens were immersed. Both type of specimens immersed in water (FI and CI), appeared to have higher corrosion rate based on LPR-Rc. However, upon autopsy
it was revealed that a more modest amount of corrosion occurred on the reinforcing steel
of FI and CI terminated specimens. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2014. / FAU Electronic Theses and Dissertations Collection
|
6 |
Concrete diffusivity and its correlation with chloride deposition rate on concrete exposed to marine environmentsUnknown Date (has links)
The aim of this study was to investigate the diffusion of chloride ions into concrete samples that were exposed in scenarios that simulate the splash, tidal, atmospheric, and immersed portions of a marine structure. To study the atmospheric deposition, the project also investigated the relationship between chloride ion deposition on the wet candle and its accumulation into concrete samples. Results from the wet candle experiment indicated that between 2% and 45% of the chlorides deposited per square meter of exposed area could be found within the concrete samples. After 6 months, slag G1a blocks showed the most resistance to chloride penetration in the tidal and splash simulations. After 10 months of exposure, fly ash samples had the slowest rates of diffusion in the tidal simulation while the fly ash + silica fume samples and the slag samples measured similar rates of diffusion within the tidal zone. After 90 days of curing, cylinders composed of 20% fly ash & 8% silica fume measured the highest average resistivity values and were found to be less vulnerable to chloride ion penetration than the 20% fly ash and the 50% slag concrete through rapid migration tests. / by Victor Anthony Echevarria. / Thesis (M.S.C.S.)--Florida Atlantic University, 2012. / Includes bibliography. / Mode of access: World Wide Web. / System requirements: Adobe Reader.
|
7 |
Correlation of Chloride Diffusivity and Electrical Resistance for Cracked ConcreteUnknown Date (has links)
The durability of Reinforced Concrete (RC) structures in the Marine environment is
causing serious concern in the structural infrastructure. Reinforced concrete structures,
exposed to aggressive environments, are expected to last with little or no maintenance for
long periods of time. However, one of the most serious environmental exposures that
causes degradation is Chloride Diffusion, due to shrinkage, atmospheric corrosion, and
tide-induced wet and dry conditions at the air-water interfaces of coastal structures.
Therefore, chloride diffusivity, which correlates with the electrical resistivity, has a
significant impact on the durability of concrete. Concrete chloride diffusivity has been
experimented by multiple agencies and researchers on sound concrete, but there is a
considerable need for investigation of the durability of cracked concrete in the marine
environment. The two test methods carried out are presented: Standardized American Society for Testing
and Materials (ASTM) C1202 for Rapid Chloride Permeability (RCP) and ASTM D257
for Surface Resistivity (SR), and Nordtest (NT) Build 492 for Rapid Chloride Migration
(RCM) and Bulk Resistivity (BR) for both sound (uncracked) and cracked (micro and
macro) concrete. The limitations of the ASTM method, due to measurements before the
steady-state migration is reached, does not account for leakage in cracked concrete, and the
heating of the specimen due to higher current that increase the conductivity are indicated.
The Rapid Chloride Migration test provides for the non-steady state of diffusion. Again,
Bulk Resistivity, in contradistinction to Surface Resistivity is more accurate for cracked
concrete. The correlation betweeen RCM-BR are plotted. Chloride Permeability/Migration
is an important parameter that governs the Durability of Concrete.
The principal contribution is the highlighting of the inadequacy of the current widely used
standard ASTM C1202 for diffusivity testing, and the need for revision with further
investigation. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2017. / FAU Electronic Theses and Dissertations Collection
|
8 |
The effect of South African quaternary supplementary cementitious blends on corrosion behaviour of concrete reinforcement in chloride and Sulphate mediaAkinwale, Abiodun Ebebezer 10 1900 (has links)
The aim of this study was to assess the strength, durability properties and corrosion resistance of concrete samples using supplementary cementitious blended materials. In this investigation, three supplementary concrete materials (SCMs) were used together with ordinary Portland Cement (OPC) to form cementitious blends at different proportions. The supplementary materials are silica fume (SF), ground granulated blast furnace slag (GGBS) and fly ash (FA). Sixteen (16) different proportions of the cementitious blends were produced. Tests carried out on concrete samples include slump test, compressive strength, oxygen permeability, sorptivity, porosity, chloride conductivity test, resistance to chloride and sulphate attack. The electrode potentials of tested samples were also observed using electrochemical measurements.
Concrete specimens prepared with 10%, 20%, 30%, 40%, up to 60% of blended cements replacement levels were evaluated for their compressive strength at, 7, 14, 28, 90 and 120 days while the specimens were evaluated for durability tests at 28, and 90 days respectively. The results were compared with ordinary Portland cement concrete without blended cement. Voltage, and temperature measurements were also carried out to understand the quality of concrete. The corrosion performance of steel in reinforced concrete was studied and evaluated by electrochemical half-cell potential technique in both sodium chloride, and magnesium sulphate solutions respectively. The reinforced concrete specimens with centrally embedded 12mm steel bar were exposed to chloride and sulphate solutions with the 0.5 M NaCl and MgSO4 concentrations respectively. An impressed voltage technique was carried out to evaluate the corrosion resistance of the combination of quaternary cementitious blended cement, so as to get the combination with optimum performance. Improvement of strength, durability, and corrosion resistance properties of blended concrete samples are observed at different optimum percentages for binary, ternary and quaternary samples. The effect of cementitious blends is recognized in limiting the corrosion potential of the tested SCM concrete samples. Generally, the cementitious blends with limited quantity of SF to 10% have the potential to produce satisfactory concrete. These should however be used for low cost construction, where high quality concrete is not required. / Civil and Chemical Engineering / M. Tech. (Chemical Engineering)
|