• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 204
  • 6
  • 3
  • Tagged with
  • 213
  • 213
  • 103
  • 84
  • 34
  • 33
  • 29
  • 27
  • 26
  • 26
  • 26
  • 25
  • 25
  • 25
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Uma abordagem bayesiana para estudo estatístico e geoestatístico de estimativas de salindade do solo utilizando sensor de indução eletromagnética / A boarding bayesiana for statistical study and geoestaistic of estimates of salinity of the ground using sensory of electromagnetic induction

PESSOA, Antônio Lopes 24 February 2006 (has links)
Submitted by (ana.araujo@ufrpe.br) on 2016-05-20T15:59:30Z No. of bitstreams: 1 Antonio Lopes Pesoa.pdf: 686455 bytes, checksum: 89c64469a23f829cb322108723a916c9 (MD5) / Made available in DSpace on 2016-05-20T15:59:30Z (GMT). No. of bitstreams: 1 Antonio Lopes Pesoa.pdf: 686455 bytes, checksum: 89c64469a23f829cb322108723a916c9 (MD5) Previous issue date: 2006-02-24 / This study analyzed the existing relationship among measurements of soil apparent electrical conductivity in an alluvial valley in the Agreste region of Pernambuco State and its spatial variability in the subsurface. The soil apparent electric conductivity was investigated through an electromagnetic induction EM 38 equipment. The readings have been carried out both in the vertical and horizontal modes. The measurements have been analyzed through the classic descriptive statistics as well as geostatistics and bayesian approach. The statistical analyses had shown that the data of apparent electric conductivity had adjusted to a normal distribution, presenting a high space variability for the horizontal mode and an average space variability for the way of vertical operation. In order to allow the use of the geostatistical methodology, the experimental semivariogram was constructed, and fitted to a theoretical model. Considering the spatial dependence mapping of the salinized areas have been performed. The best theoretical models for the vertical mode and for the horizontal operation were the gaussian model and the exponential model, through the crossed validation and using the Akaike’s Information Criterion .The bayesian approach focused the spatial predictionrelating the method of the maximum likelihood with the functions of prioris distributions for each parameter, considering the uncertainty associated to each one of these distributions. It was verified that the adjusted semivariograms had not presented significant differences in the validation of the geostatistics methodology and in the bayesian approach. / Esta dissertação analisou a relação existente entre medidas de condutividade elétrica aparente de um solo aluvial da região Agreste do Estado de Pernambuco,e a sua variabilidade espacial na camada subsuperficial. A condutividade elétrica aparente do solo foi investigada através de equipamento de indução eletromagnética EM 38. As leituras efetuadas com o EM 38 foram tanto no modo vertical como no modo horizontal. As medidas obtidas em campo foram analisadas através da estatística descritiva clássica, bem como através das metodologias geoestatística e abordagem bayesiana. As análises estatísticas mostraram que os dados de condutividade elétrica aparente se ajustaram a uma distribuição normal a apresentaram uma alta variabilidade espacial para o modo de operação horizontal e uma média variabilidade espacial para o modo de operação vertical. Através da metodologia geoestatística foi construído o semivariograma experimental que, posteriormente, foi ajustado a um modelo teórico. O melhor ajuste de modelo teórico foi obtido, tanto para o modo de operação vertical como para o modo de operação horizontal, para o modelo gaussiano e para o modelo exponencial, efetuada através da validação cruzada edo Critério de Informação de Akaike. A partir da dependência espacial, foi elaborado o mapeamento das áreas salinizadas. A abordagem bayesiana focalizou a predição espacial, relacionando o método da máxima verossimilhança com as funções de distribuições prioris de cada parâmetro, considerando o grau de incerteza associado a cada uma dessas distribuições. Verificou-se que os semivariogramas ajustados não apresentaram diferenças significativas na validação da metodologia geoestatística e na abordagem bayesiana.
192

Influência da condutividade e permissividade do solo em função da frequência no cálculo da impedância longitudinal e admitância transversal de linhas aéreas de transmissão / Influence of earth's conductivity and permittivity frequency dependence on longitudinal impedance and transversal admittance transmission line's parameters calculation

Gertrudes, João Bosco 16 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-16T03:57:35Z (GMT). No. of bitstreams: 1 Gertrudes_JoaoBosco_D.pdf: 5500576 bytes, checksum: ef85206048f845d1bff89f7c8948d288 (MD5) Previous issue date: 2010 / Resumo: Esta tese tem como objetivo o desenvolvimento de modelos mais precisos para o cálculo de parâmetros elétricos de linhas aéreas de transmissão para estudos de transitórios na faixa de frequência 0 a 2 MHz. Esta faixa de frequência cobre a maioria das perturbações eletromagnéticas nos sistemas elétricos: energização, faltas simétricas e assimétricas, rejeições de carga, descargas atmosféricas, perturbações harmônicas, etc. Na faixa de frequência citada, em consequência da dependência dos parâmetros do solo com a frequência, a condutividade elétrica do solo (sg) tem a mesma ordem de grandeza que o produto entre a frequência angular do sinal incidente no solo (w) e a permissividade elétrica do solo (eg). Portanto, as suposições de baixa frequência tradicionalmente adotadas - sg constante e weg desprezível (sg >> weg) - podem levar a modelos que não representam de forma adequada a resposta da linha no caso de transitórios rápidos (com espectro de frequência acima de 1 kHz). O objetivo central desta tese é verificar a influência da dependência dos parâmetros do solo no cálculo da impedância longitudinal e admitância transversal por unidade de comprimento em comparação com os modelos tradicionais de cálculo. As análises são feitas inicialmente para o caso de um único condutor acima do solo e posteriormente através de um estudo para uma linha de transmissão trifásica, 440 kV, em operação no sistema elétrico brasileiro. As impedâncias longitudinais e as admitâncias transversais de retorno pelo solo são avaliadas através de métodos tradicionais de cálculo e através de integração numérica das formulações de Carson modificadas para inclusão do modelo de solo que considera a depêndencia de sg e weg em função da frequência / Abstract: This thesis aims to propose more accurate models for calculating the electrical parameters of overhead power transmission lines. The influence of earth's conductivity and permittivity frequency dependence is evaluated when calculating transversal and longitudinal transmission lines' parameters in the frequency range 0 to 2 MHz. This frequency range covers the majority of the electromagnetic transients in electrical systems (switching transients, faults' transients, load rejections, harmonic disturbances, etc). Between 1 kHz to 2 MHz, the product of the signal angular frequency (w) by the dielectric constant (eg) of the soil may have the same order of magnitude as the conductivity (sg), due to the variation of these parameters with frequency. Therefore, the assumptions of low frequency traditionally used - the soil conductivity (sg) considered as constant and weg that can be negligible (sg >> weg) - can lead to incorrect models that do not adequately represent the transmission line's response, in cases of fast transients phenomena (with frequency spectrum above 1 kHz). The importance of properly considering the frequency dependent soil model is presented for the one-conductor case and for a single three-phase transmission line (440 kV, considered ideally transposed). The aim is to compare the transmission line parameters calculated considering the conductivity and weg frequency dependence ground model in relation to the common ground representation, with constant conductivity and weg that may be neglected. It is also compared the results obtained from the complex plane method with those obtained from the Carson's modified expressions for longitudinal parameters and between Carson's modified potential-coefficient correction factors and from the most common approximated methods for transversal admittance parameters / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
193

Estudo das propriedades elétricas de compósitos carbono-argila obtidos a partir da borra de petróleo pelo método de quatro pontas / STUDY OF ELECTRICAL PROPERTIES OF CARBON-CLAY COMPOSITES OBTAINED FROM THE METHOD OIL SLUDGE FOUR TIPS

Sousa, Makcydra Amisterdania Costa Ferreira 05 March 2010 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / The petroleum industry produces significant amounts of residues in several of its processes, from the perforation of wells, production, storage, transport and refining, to the distribution of its derivatives. The wastewater generated in the oil extraction step is known as produced water and, when stored in flotation tanks, if generates a residue called oily sludge . In a previous report, carbon-clay composites were obtained from this oily sludge and it was found this the material shows semiconductor properties. Thus, here we aimed to further evaluate the electrical properties of the carbon-clay composites using a home-made four probe apparatus. The carbon-clay composites have been prepared using the pyrolysis conditions reported in the previous study, changing here the precursor granulometry then afterwards characterizing the samples by FTIR, XRD, Raman and SEM. The presence of clays-mineral phases as well as carbon rich phases was evidenced from FTIR spectroscopy. Raman spectra revealed the presence of graphitic crystallites in addition to a disordered carbon matrix. XRD data allowed us to properly identify the mineral phases. SEM images have shown a clear effect of the precursor granulometry on the microstructure of the final pellets. Compact pellets can be expected when using a precursor with smaller particle size. The electrical measurements were accomplished using both a current source especially built for this and alternatively a Keithey 237 electrometer coupled to the four-probe apparatus. Satisfactory current values in terms of stability and reproducibility were obtained with both sources in the range of 640 μA (minimum potential) 37 mA (maximum potential). Applying current values in this range for the carbon-clay composite samples it was possible to confirm their semiconductive properties, since conductivities were found to lie in the range ≈10-4 (Ω*cm)-1. Finally the sample compactness was found to play a significant role in the electrical conductivity since the higher conductivity values were found for more compact samples. / A indústria petrolífera produz quantidades significativas de resíduos em vários dos seus processos, desde a perfuração de poços até a distribuição de seus derivados. Nesse ambiente industrial surge a chamada água produzida, que ao ficar em tanques de flotação, gera um resíduo chamado de borra de petróleo . A partir de uma observação preliminar, realizada por Andrade et al, do compósito carbono-argila, utilizando a espectroscopia de impedância eletroquímica, foi possível identificar que o material em estudo é um semicondutor. Desta maneira, surgiu o interesse de estudar com mais profundidade as características elétricas do mesmo. O objetivo deste trabalho é realizar um estudo das propriedades elétricas do compósito, destacando seus parâmetros principais como condutividade e resistividade elétricas, pelo método de quatro pontas e caracterizar a borra de petróleo gerada no tratamento de água produzida. A borra de petróleo foi seca inicialmente por 48 horas a 110ºC, foram feitas pastilhas com material peneirado a granulometrias diferentes e depois sinterizadas sob atmosfera inerte de nitrogênio, até 800ºC com isoterma de 2h. Em seguida, foi realizada a montagem do aparato de quatro terminais utilizando eletrodos de latão e de platina, para medição de resistividade elétrica do material e a montagem de uma fonte de corrente constante. Através do espectro FTIR, observou-se banda referentes aos estiramento O-H de argilominerais; bandas de resíduos orgânicos; e banda dos componentes minerais. As análises de DRX apresentaram como constituintes a montmorilonita, quartzo, calcita e barita, bem como a cristobalita, ghelenita, anortita e magnetita. O Raman apresentou banda devido à presença de carbono grafite e banda devido à desordem na estrutura do carbono grafite. A análise por MEV apresentou em algumas amostras superfície mais compactada com a presença de grãos e aglomerados. Tanto com a fonte construída, quanto com um eletrômetro obteve-se uma estabilidade de corrente na faixa de 640μA a 37mA. Foi possível comprovar com ambas as medidas que o material em estudo é um material que apresentou um valor de condutividade na faixa da semicondução (≈10-4 Ω.cm)-1.
194

Metodologia para correlacionar a umidade, compactação e a condutividade elétrica aparente do solo / Methodology to correlate the humidity, compaction and soil apparent electrical conductivity

Silva Filho, Antônio Marcelino da 19 December 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-11-30T09:09:36Z No. of bitstreams: 2 Dissertação - Antônio Marcelino da Silva Filho - 2015.pdf: 2204549 bytes, checksum: 2f0941c7970eff84c86b64f4fd261cb6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-11-30T09:11:40Z (GMT) No. of bitstreams: 2 Dissertação - Antônio Marcelino da Silva Filho - 2015.pdf: 2204549 bytes, checksum: 2f0941c7970eff84c86b64f4fd261cb6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-11-30T09:11:40Z (GMT). No. of bitstreams: 2 Dissertação - Antônio Marcelino da Silva Filho - 2015.pdf: 2204549 bytes, checksum: 2f0941c7970eff84c86b64f4fd261cb6 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-12-19 / This work presents the study of the relationship between soil apparent electrical resistivity ρa and the moisture content, clay content and soil compaction, for use of the ρa as a mapping tool of spatial soil variability. The values of apparent electrical resistivity are obtained by geoelectrical prospecting methods that detect the effects produced by the flow of electrical current in the soil. It is used the Wenner array and the technique of Lateral Profiling for data collection. It was held measures of ρa in different soil types, varying moisture content gradually while maintaining a constant compaction, and then varying the compaction and relating it to a constant humidity. To the study of spatial variability, it was chose two areas that would enable the change of moisture and compaction content, in order to verify the measurement capacity of ρa as methodology of identification of change in soil dynamics. The results obtained are presented and discussed. / Este trabalho apresenta o estudo das rela¸c˜oes entre a resistividade el´etrica aparente do solo ρa e o teor de umidade, teor de argila e compacta¸c˜ao do solo, para utiliza¸c˜ao de ρa como ferramenta de mapeamento da variabilidade espacial do solo. Os valores da resistividade el´etrica aparente s˜ao obtidos atrav´es de m´etodos de prospec¸c˜ao geoel´etricos que detectam os efeitos produzidos pelo fluxo de corrente el´etrica no solo. Utilizam-se o arranjo de Wenner e a t´ecnica do Caminhamento El´etrico para coleta dos dados. Realizaram-se medidas de ρa em diferentes tipos de solo, variando-se gradualmente o teor de umidade, mantendo-se constante a compacta¸c˜ao, e posteriormente variando a compacta¸c˜ao em fun¸c˜ao de valor constante de umidade. Para o estudo da variabilidade espacial, escolheram-se duas ´areas que possibilitassem a altera¸c˜ao dos teores de umidade e compacta¸c˜ao, a fim de verificar a capacidade da medi¸c˜ao de ρa como metodologia de identifica¸c˜ao de altera¸c˜oes na dinˆamica do solo. Os resultados obtidos s˜ao apresentados e discutidos.
195

Processamento, microestrutura e propriedades de compósitos à base de cobre reforçados com alumina e céria / Processing, microstructure and properties of the copper-based composites reinforced with alumina and ceria

Daniela Passarelo Moura da Fonseca 31 August 2018 (has links)
Compósitos de matriz metálica combinam diferentes classes de materiais a fim de obter novas propriedades, superiores às dos materiais originais. A adição de partículas cerâmicas (reforço) em ligas de cobre pode melhorar suas propriedades mecânicas sem gerar grande perda na condutividade elétrica. Este trabalho teve como objetivo processar e estudar a microestrutura e propriedades (condutividade elétrica, dureza e fratura) de compósitos à base de cobre reforçados com alumina e céria. As amostras foram processadas pela técnica de metalurgia do pó: pesagem, mistura (sem bolas por 30min a 46 rpm), compactação (uniaxial à frio com pressão de 1080 Mpa por 10s) e sinterização (800°C por 6h sob vácuo de 10-5 torr). As análises de MO, MEV, EDS e DRX (com refinamento Rietveld) indicaram boa coalescência das partículas, formando superfície continua e com baixa porosidade. A alumina formou regiões aglomeradas da ordem de 20 μm, a céria ficou finamente dispersa nos contornos de grão do cobre com algumas regiões aglomeradas, o cromo formou regiões de cerca de 100 μm e não teve distribuição completamente uniforme ao longo da matriz, a prata formou solução sólida com o cobre e, durante o resfriamento lento, formou precipitados menores do que 5 μm uniformemente dispersos no interior dos grãos de cobre. Os compósitos apresentaram condutividade elétrica entre 15 e 40 %IACS, dureza entre 62 e 88 HV5 e as fractografias apresentaram fratura mista e regiões indicando boa adesão matriz-reforço. Em relação ao cobre puro, foi observado efetivo aumento na dureza (cerca de 2x), porém, em todos os compósitos, o acréscimo da fase cerâmica acarretou na diminuição da condutividade elétrica. Os compósitos de Cu-8%(Al2O3, CeO2) foram os que apresentaram melhor equilíbrio entre essas duas propriedades, com condutividade de 40 e 38 %IACS e dureza de 63 e 69 HV5. / Metal matrix composites combine different classes of materials to obtain new properties, superior to those of the original materials. The addition of ceramic particles (reinforcement) in copper alloys could improve their mechanical properties without generating great loss in electrical conductivity. The aim of this work was to process and study the microstructure and properties (electrical conductivity, hardness and fracture) of copper-based composites reinforced with alumina and ceria. The samples were processed by the powder metallurgy technique: weighing, blending (no balls for 30 min at 46 rpm), compaction (cold uniaxial at 1080 MPa for 10s) and sintering (800°C for 6 h under vacuum of 10-5 torr). Analysis of OM, SEM, EDS and XRD (with Rietveld refinement) indicated good coalescence of the particles, forming continuous surface with low porosity. The alumina formed agglomerated regions with approximately 20 μm, the ceria was finely dispersed in the grain boundary of the copper with some agglomerated regions, the chromium formed regions of about 100 μm and have a non-uniform distribution throughout the matrix, the silver formed solid solution with copper and, during slow cooling, formed precipitates smaller than 5 μm, uniformly dispersed inside the copper grains. The composites presented electrical conductivity between 15 and 40 %IACS, hardness between 62 and 88 HV5 and the fractographs presented mixed fracture and regions indicating good matrix-reinforcement adhesion. In relation to pure copper, it was observed an increase in hardness (about 2x), however, in all the composites, the increase of the ceramic content led to a decrease in the electrical conductivity. The Cu-8%(Al2O3, CeO2) composites showed the best balance between these two properties, with conductivity of 40 and 38 %IACS and hardness of 63 and 69 HV5.
196

Contribuição ao estudo de distúrbios ionosféricos utilizando a técnica de VLF

Cruz, Edith Liliana Macotela 09 March 2015 (has links)
Made available in DSpace on 2016-03-15T19:35:50Z (GMT). No. of bitstreams: 1 EDITH LILIANA MACOTELA.pdf: 4190613 bytes, checksum: 95f5d6f4988fd94b74e81390b34799d8 (MD5) Previous issue date: 2015-03-09 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / The Earth-Low ionosphere system behaves as a waveguide for the propagation of radio waves of very low frequency (VLF). If in this system the electrical conductivity of its boundaries is perturbed, the propagation of the VLF waves will also be perturbed. There is a diversity of transient physical phenomena that are able to alter significantly the electrical conductivity of the lower ionosphere. The disturbance in this region is able to produce phase and amplitude variations with respect to a quiescent level of these waves. The aim of the present work is to study the response of the lower ionosphere to phenomena originated in the Earth, our solar system or even much farther away. For this purpose, VLF data obtained by SAVNET (South American VLF Network) during the solar cycle 24 was used. It was found that the correction by both the length of the path illuminated by the flare and the reference height coefficient allows normalizing the effect of ionospheric disturbances observed in the VLF phase signals that propagated along trajectories with a north-south or west-east direction, separately. The lower limit of detection for disturbances caused by the X-ray radiation excess is 1.8×10−9 Jm-2 and 2.6×10−7 Jm-2 for the nighttime and daytime lower ionosphere, respectively. Changes in the periodicities of the VLF signal, in the infrasonic band, were observed between 6 and 14 days prior to the seismic events, of magnitude 7, occurred in Haiti in 2010 and in Peru in 2011. Increases in the periodicities of the order of few minutes were observed when the shadow of the total solar eclipse of 2010 was moving on the Earth. Due to the solar eclipse the ionospheric reference height increased in ~3 km and the electron density decreased in 60 % of its quiescent level. Finally, it was found that the effective recombination coefficient, for 80 km height, was 1.1×10−5 cm-3s-1 during the time of the eclipse, which is an intermediate value between the diurnal and nocturnal conditions. / O sistema Terra-baixa ionosfera se comporta como um guia de onda para a propagação de ondas de rádio de frequências muito baixa (VLF). Se neste sistema a condutividade elétrica das fronteiras é perturbada, a propagação da onda é também perturbada. Existe uma variedade de fenômenos físicos transientes que alteram significativamente a condutividade elétrica da baixa ionosfera. Essas alterações são observadas como variações da fase e/ou amplitude com respeito ao nível quiescente. O presente trabalho tem como finalidade estudar a resposta da baixa ionosfera a fenômenos que produzidos na Terra, no sistema solar e até aqueles produzidos muito além do sistema solar. Com esse fim foram utilizados dados de VLF de fase e de amplitude fornecidos pela rede SAVNET (South America VLF NETwork) para o ciclo solar 24. Foi encontrado que a correção pelo fator de distância iluminada e o coeficiente de altura de referência permitem normalizar o efeito do distúrbio ionosférico a partir do sinal de VLF propagado em trajetos com direção de propagação norte-sul ou oeste-leste. O limiar de detecção das perturbações causadas pelo excesso na incidência dos raios-X é 1,8×10−9 Jm-2 para a ionosfera noturna e 2,6×10−7 Jm-2 para a ionosfera diurna. Perturbações ionosféricas observadas como alterações nos períodos do sinal de VLF, na faixa de infrassom, foram observadas entre 6 e 14 dias antes dos eventos sísmicos de magnitude 7 acontecidos no Haiti no ano 2010 e no Peru no ano 2011. Alterações nas periodicidades, da ordem de dezenas de minutos, foram observadas quando a sombra do eclipse solar total de 2010 se deslocava sobre a Terra. Devido ao eclipse, a altura de referência da ionosfera aumentou em ~3 km e a densidade eletrônica diminuiu em 60% com respeito do nível quiescente. Finalmente, foi encontrado que o coeficiente de recombinação efetiva, para o tempo do eclipse e para uma altura de 80 km, foi de 1,1×10−5 cm-3s-1, que é um valor intermediário entre as condições diurnas e noturnas.
197

Síntese de ligas à base de Cu-Ni-Ag de alta condutividade elétrica

Luongo, Leilah Delaretti 22 May 2015 (has links)
Made available in DSpace on 2016-03-15T19:36:50Z (GMT). No. of bitstreams: 1 Leilah Delaretti Luongo.pdf: 2162579 bytes, checksum: 76c30f5d2ee2f42b33cf84bd04999ac2 (MD5) Previous issue date: 2015-05-22 / In this work, samples of copper-silver and silver-copper-nickel alloys were synthesized by powder metallurgy. The alloys have received sintering and all of them were characterized metallographically. Different and significant effects were observed in the microstructure and conductivity of the samples studied. The influence of silver on the conductivity of the samples with nickel resulted to be lower than the alloy with chromium and nickel, studied in previous work of the research group, where the same procedures were applied to the same precursors. An interesting result is that the larger crystallite size favored the high electrical conductivity, which is presented in the samples without nickel. The presence of nickel helped to inhibit oxidation and the difference in the amount of nickel influenced the alloys behavior, however, it did not guarantee high conductivity observed in the aforementioned alloys copper-nickel-chromium. The structure of the samples was studied by the Rietveld Method, using data from x-ray diffraction. The differences in microstructure were investigated by comparing the parameters of the pure copper used as a precursor profile. / Neste trabalho foram sintetizadas amostras de ligas metálicas de cobre-prata e cobre-níquel-prata obtidas por metalurgia do pó. As ligas receberam tratamentos térmicos de sinterização e foram caracterizadas metalograficamente. Foram observados efeitos diferentes e significativos na microestrutura e na condutividade das amostras estudadas. A influência da prata na condutividade das amostras com níquel resultou ser inferior à de ligas com cromo e níquel, estudadas em trabalhos precedentes do grupo de pesquisa, onde se aplicaram os mesmos procedimentos aos mesmos precursores. Um resultado interessante é que o maior tamanho de cristalito favoreceu a condutividade elétrica, o qual se apresentou nas amostras sem níquel. A presença do níquel ajudou a inibir a oxidação e a diferença na quantidade de níquel se mostrou importante no comportamento das ligas, porém, não garantiu a alta condutividade verificada nas mencionadas ligas de cobre- níquel-cromo. A estrutura das amostras foi estudada pelo Método de Rietveld, usando dados de difração de raios x. As diferenças na microestrutura foram estudadas através da comparação com os parâmetros de perfil do cobre puro usado como precursor.
198

Comportamento fisiológico e bioquímico de sementes e grãos de feijão durante o armazenamento.

Cassol, Flavia Danieli Rech 07 February 2013 (has links)
Made available in DSpace on 2017-07-10T19:23:36Z (GMT). No. of bitstreams: 1 Flavia.pdf: 1168497 bytes, checksum: f97523b328660e75a0d87b8afe672f21 (MD5) Previous issue date: 2013-02-07 / Beans are one of the foods used to supply the energy needs of the Brazilian diet, so it is necessary that farmers use high seed physiological potential, capable of increasing crop productivity. Thus, the aim of this study was to evaluate the physiological and biochemical changes occurring in beans stored for 360 days. Analyses were performed at 0, 30, 90, 180, 270, and 360 days after receiving the seeds (S1 and S2) and grains (G1 and G2) of BRS Radiance, coming from two producers. Tests of germination, accelerated aging, cold, and index of germination speed (IVG), average length of shoot (CMPA) and of root (CMR), electrical conductivity and the electrical conductivity of the leachate were quantified in levels of sugars and amino acids, in addition to Ca, K, Mg, Mn, Fe, and Zn. The experimental design was completely randomized split-plot in time and the means were compared by the Tukey test at 5% probability. Seed germination was not affected in S2, while S1 and G1 showed a significant fall. The grains from field 1 had a greater influence on heat, stress, and cold, with its vigor decreasing from 91 to 50% and from 93 to 76%, respectively, after 360 days. The IVG tests presented decreased during the experiment. The CMPA and CMR samples showed variations during the experiment, and G1 had the lowest means. In electrical conductivity greater loss of solutes occurred at 90 days of evaluation. Up to 180 days of storage, G1 presented higher amount of amino acids and at 360 days the greatest value S1. Larger amount of soluble sugars were found in samples from field 1. The amount of calcium ions, manganese, iron, and zinc found in the samples were very small. The amounts of potassium decreased until 360 days of storage, and G1 showed the highest value. After 90 days the amounts of magnesium of the samples increased considerably. The grains from field 1 had lower physiological quality. The tests of accelerated aging, cold, and IVG showed a drop in vigor of the Splendor BRS, whereas the electrical conductivity test was not sensitive enough to detect this decrease. This test did not present association with the quantification of the ions investigated. The amount and behavior of amino acids, sugars the ions studied in this work, failed to relate these variables to the decrease in vigor of the bean samples. The storage period influenced the physiological quality of the beans tested. / O feijão é um dos alimentos mais utilizados para suprir as necessidades energéticas da dieta dos brasileiros. Assim, é necessário que os agricultores utilizem sementes de alto potencial fisiológico, capazes de aumentar a produtividade da cultura. Desta forma, o objetivo deste trabalho foi avaliar a qualidade fisiológica e as mudanças bioquímicas ocorridas em feijões armazenados por 360 dias. As análises foram realizadas nos tempos 0, 30, 90, 180, 270 e 360 dias após o recebimento dos lotes de sementes (S1 e S2) e dos grãos (G1 e G2) da cultivar BRS Esplendor vindas de dois produtores. Foram realizados os teste de germinação, de envelhecimento acelerado, de frio, além de índice de velocidade de germinação (IVG), comprimento médio da parte aérea (CMPA) e da raiz (CMR), condutividade elétrica e do lixiviado da condutividade elétrica foram quantificados os teores de açúcares e aminoácidos, além dos íons Ca, K, Mg, Mn, Fe e Zn. O delineamento foi inteiramente casualizado em esquema de parcelas subdivididas no tempo e as médias comparadas pelo teste de Tukey, ao nível de 5% de probabilidade. A porcentagem de germinação não foi afetada para S2, enquanto que nas S1 e G1 a queda foi significativa. Os grãos do campo 1 sofreram maior influência sobre estresse de calor e frio, tendo seu vigor diminuído de 91 para 50% e de 93 para 76%, respectivamente, após 360 dias. O IVG dos testes realizados apresentaram queda durante o experimento. O CMPA e o CMR das amostras apresentaram variações ao longo do experimento, sendo que G1 apresentou as menores médias. No teste de condutividade elétrica maior perda de solutos ocorreu aos 90 dias de avaliação. Até os 180 dias de armazenamento, G1 apresentou maior quantidade de aminoácidos e aos 360 dias S1, o maior valor. Maiores quantidade de açúcares solúveis foram evidenciadas nas amostras do campo 1. A quantidade dos íons cálcio, manganês, ferro e zinco encontrados nas amostras foram muito pequenas. As quantidades de potássio diminuíram até os 360 dias de armazenamento, quando G1 apresentou o maior valor. Após 90 dias, as quantidades de magnésio das amostras aumentaram consideravelmente. Os grãos do campo 1 apresentaram menor qualidade fisiológica. Os testes de envelhecimento acelerado, frio e IVG evidenciaram a queda do vigor da cultivar BRS Esplendor, enquanto que o teste de condutividade elétrica não foi sensível para detectar esta diminuição. Este teste não apresentou relação com a quantificação dos íons investigados. A quantidade e o comportamento dos aminoácidos, açúcares e dos íons estudados não permitiram relacionar estas variáveis com a queda do vigor das amostras de feijão. O período de armazenamento influenciou a qualidade fisiológica dos feijões testados.
199

Avaliação de uma sonda TDR helicoidal para a estimativa do teor de umidade de solos em campo e laboratório / Evaluation of a helicoidal TDR probe to estimate the soil water content in laboratory and in situ

Cleber Decarli de Assis 09 May 2008 (has links)
Este trabalho de pesquisa apresenta a avaliação de uma sonda TDR helicoidal para estimar o teor de umidade dos solos, em diferentes profundidades, através da técnica da reflectometria no domínio do tempo (TDR). Essa sonda, desenvolvida especificamente para esse fim, foi devidamente calibrada em laboratório para diferentes tipos de solo. O processo de calibração consistiu na determinação da constante dielétrica aparente (Ka) e condutividade elétrica volumétrica (ECb) de um mesmo solo com diferentes teores de umidade. Posteriormente foram buscadas correlações entre Ka e o teor de umidade gravimétrico (w), obtido em estufa. São propostas correlações entre w e Ka, entre w e \'KA POT. 1/2\' e entre teor de umidade volumétrico (\'teta\') e Ka. Também foram consideradas as correlações propostas por Yu e Drnevich (2004), visando estimar também a massa específica seca dos solos. Foram realizados ensaios de campo para a validação das equações de calibração. Os valores dos teores de umidade estimados através da técnica da reflectometria no domínio do tempo, tanto em laboratório como em campo, foram comparados com os valores de teor de umidade obtidos com o método da estufa. Com base nos resultados foram determinados os erros referentes às calibrações. Nos ensaios de campo, os teores de umidade obtidos através da correlação entre w e \'KA POT. 1/2\' apresentaram melhores resultados, quando comparados com aqueles estimados com as outras correlações. Pelos resultados obtidos conclui-se que a técnica TDR é uma alternativa viável para a estimativa em campo do teor de umidade em grandes profundidades. / In this work is presented the evaluation of a recently developed helicoidal probe used for estimating the soil water content through the time domain technology (TDR). This probe has been calibrated in laboratory for different types of soils. The calibration process consisted in assessing the values of the apparent dielectric constant (Ka) and the bulk electric conductivity (ECb) of a specific soil at different levels of water content (w). Subsequently, correlations between the apparent dielectric constant and the water content have been established. The same has done with the bulk electric conductivity. Correlations between Ka and w, \'KA POT. 1/2\' and w, \'teta\' (volumetric water content) and Ka have been proposed. Also, the correlations proposed by Yu and Drnevich (2004) have been considered. To validate the proposed correlations, tests using the helicoidal probe were performed in the field. Estimated values of field water content, using the TDR technology have been compared to the correspondent oven water content values. Based on these comparisons, errors regarding the calibrations have been calculated. In the field tests, the correlations between \'KA POT. 1/2\' and w have presented more accurate results than those obtained with the other correlations. Experimental results have shown that the TDR technology for estimating water content at different depths in the field is feasible and expedite.
200

Pré-hidratação de sementes de ervilha e sua interferência na avaliação do potencial fisiológico / Pea seed pre hydration and its interference with the evaluation of the physiological potential

Costa, Caroline Jácome 22 February 2007 (has links)
Made available in DSpace on 2014-08-20T13:44:37Z (GMT). No. of bitstreams: 1 tese_caroline_costa.pdf: 410037 bytes, checksum: 70221bc02297589fd9d80d107be7a2aa (MD5) Previous issue date: 2007-02-22 / The present work had the objective of to study biochemical and physiological alterations in function of pea seed pre hydration with e phasis in the electrolyte leakage and in the expression of different isoenzymatic systems,trying to contribute for the i provement of the pre hydration methods of seeds to be submitted to tests for evaluation of its physiological potential.Seeds lots of cvs.Axé and Maria, characterized for the water content,germination,first ger mination counting,accelerated aging,electrical conductivity and seedling emergence in the field,were used.The seeds of each lot were pre hydrated in saturated atmosphere and hum idified substratu until they reach 10,12 and 14%of water content.After the pre hydration,the seeds were submitted to the tests of electrical conductivity,accelerated aging and leakage of calcium ,potassium and magnesium and characterized for the expression pattern of the isoenzymatic systems Malate Dehydrogenase,Acid Phosphatase,Glutamate Dehydrogenase and Glutamate Oxalacetate Transaminase.The pre hydration of the seeds using saturated atmosphere or humidified substratum see s to affect the process of restructuring the seed cellular e branes system differently,being reflected in alterations in the pattern of electrolyte leakage and Acid Phosphatase isoenzymatic expression.Discrepancies take place a ong results obtained by the test of electrical conductivity for evaluation of the physiological potential of pea seeds,depending on the proceeding adopted to pre hydrate the seeds. / O presente trabalho teve o objetivo de estudar alterações bioquímicas e fisiológicas decorrentes da pré hidratação de sementes de ervilha,com ênfase na lixiviação de eletrólitos e na expressão de diferentes sistemas isoenzim áticos,procurando contribuir para o aperfeiçoamento dos métodos de pré hidratação de sementes a serem submetidas a testes para avaliação do seu potencial fisiológico.Foram utilizados lotes de sementes de ervilha das cultivares Axé e Maria,caracterizados quanto ao teor de água,germinação, primeira contagem de germinação,envelhecimento acelerado,condutividade elétrica e emergência de plântulas e campo.As sementes de cada lote fora pré hidratadas e pregando atmosfera saturada e substrato umedecido,até atingirem teores de água de 10, 12 e 14%.Após a pré hidratação,as sementes foram avaliadas pelos testes de condutividade elétrica,envelhecimento acelerado,lixiviação de cálcio,potássio e magnésio e caracterizadas quanto ao padrão de expressão dos sistemas isoenzimáticos Malato Desidrogenase,Fosfatase Ácida,Glutamato Desidrogenase e Glutamato Oxalacetato Transaminase.A pré hidratação de sementes de ervilha e pregando atmosfera saturada ou substrato umedecido afeta diferentemente o processo de reestruturação do sistema de e branas celulares das sem entes,refletindo se e alterações no padrão de lixiviação de eletrólitos e na expressão do sistema isoezimático Fosfatase Ácida.Ocorre discrepâncias entre resultados obtidos pelo teste de condutividade elétrica para avaliação do potencial fisiológico de sementes de ervilha,dependendo do procedim ento adotado para a pré hidratação das sementes.

Page generated in 0.0914 seconds