• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise paramétrica do comportamento de condutos enterrados flexíveis e de grande diâmetro

Silveira, Kênia Damasceno 19 December 2001 (has links)
Neste trabalho apresenta-se uma análise paramétrica de um sistema composto por cinco condutos flexíveis enterrados, paralelos e de grande diâmetro. Analisou-se o comportamento dessas estruturas em relação à altura de cobertura do aterro, à posição de atuação de cargas externas, ao espaçamento horizontal entre condutos e aos parâmetros geotécnicos do solo, tais como, módulo de elasticidade, ângulo de atrito, coesão e grau de compactação. Para a realização das análise utilizou-se o programa SSCOMPPC (BOULANGER et al, 1991) baseado no método dos elementos finitos (MEF). Implementou-se em Visual Basic um pré/pós-processador com o intuito de facilitar a entrada de dados, a geração da malha, bem como, a visualização dos deslocamentos e dos esforços finais no conduto. Os resultados obtidos revelam que os momentos fletores atuantes são mais críticos no topo e nos ombros das estruturas quando estas estão sujeitas a cargas de tráfego. O deslocamento crítico ocorre no topo das estruturas de maiores vãos. Quanto à atuação das tensões verticais, devido ao peso próprio do aterro e às cargas de tráfego, estas são totalmente dissipadas no solo para alturas de cobertura de aterro superiores a 3,0m. Além disto, a estabilidade dos condutos instalados é proporcional ao grau de compactação e ao módulo de elasticidade do solo. A variação dos parâmetros de resistência do solo apontou a coesão como um fator muito significativo no comportamento das estruturas
2

Identificação de instabilidades hidráulicas em sistema de drenagem urbana : investigação experimental do conduto forçado Álvaro Chaves

Silva, Juliana Kaiber da January 2015 (has links)
O Conduto Forçado Álvaro Chaves (CFAC), grande obra de drenagem urbana realizada na cidade de Porto Alegre (Brasil) e implantado entre 2005 e 2008, para amenizar alagamentos em ruas e avenidas de uma região altamente populosa, com cerca de 2,8km2. A concepção e dimensionamento do CFAC chamam atenção por alguns aspectos pouco usuais: um reservatório de detenção e um conduto forçado combinados na mesma estrutura e seção transversal retangular, diminuindo de montante para jusante. Além disso, também apresenta contrações verticais e horizontais sem concordâncias apropriadas, desnível geométrico abrupto e mudança de direção em ângulos vivos com diminuição da seção transversal. Esse sistema de drenagem deságua no Rio Guaíba. Em fevereiro de 2013, o CFAC ganhou notoriedade, devido ao colapso de parte de sua estrutura durante um forte evento chuvoso. A cobertura de concreto armado do CFAC foi deslocada e o solo removido, causando o afundamento do pavimento. Para investigar o CFAC, um modelo de detalhe em escala reduzida foi construído no Pavilhão Fluvial do Instituto de Pesquisas Hidráulicas da Universidade Federal do Rio Grande do Sul. A escala de redução geométrica adotada é de 1:15, resultando em um modelo de 30 m de comprimento, com alturas (16 – 42 cm) e larguras variáveis (20 – 50 cm). O modelo reproduz o reservatório de detenção, suas duas entradas e parte do conduto forçado à jusante do reservatório de detenção. O procedimento experimental baseia-se na propagação de um hidrograma no interior do conduto. As variáveis experimentais são a vazão afluente inicial, a configuração de abertura dos registros de jusante (essas duas variáveis condicionam o nível d’água inicial) e o tempo de abertura dos registros de montante. Os principais dados, gerados nos ensaios, são imagens obtidas em vídeo (câmeras normais e câmera rápida) e registros de vazão. A minuciosa análise das imagens permitiu o estabelecimento de três padrões de enchimento do conduto, apresentados a seguir. Padrão A – Enchimento do conduto sem aprisionamento de bolsões de ar e pressurização quasi-steady: observado em ensaios em que as condições de drenagem são mais favoráveis, resultando nos menores níveis iniciais de água no interior do conduto, dada uma vazão afluente. Esse padrão representa situações em que o nível do Rio Guaíba está mais baixo, permitindo maior capacidade de drenagem do sistema. Padrão B – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização quasi-steady: estabelece-se, mediante condições de drenagem um pouco mais restritivas do que no Padrão A, resultando em maiores níveis iniciais para as mesmas vazões afluentes. Situações em que o nível do Rio Guaíba encontra-se mais elevado podem ser associadas a esse padrão. Padrão C – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização unsteady: as condições de drenagem mais adversas condicionam o estabelecimento do Padrão C e resultam em altos níveis iniciais, mesmo para vazões iniciais bastante baixas. Esse padrão representa as condições mais extremas ensaiadas, seja em relação aos níveis do Rio Guaíba associados, seja em relação à severidade das consequências observadas. Além disso, inúmeros fenômenos e instabilidades hidráulicas foram observados: transição entre o escoamento à superfície livre e pressurizado, ressaltos hidráulicos móveis, aprisionamento e movimentação de bolsões de ar, ondas oscilatórias e ondas de translação. De uma maneira geral, o modelo do CFAC permite o estudo do escoamento, em regime não permanente, em um sistema de drenagem urbana que apresenta diversas singularidades, como curvas, contrações horizontais e verticais sem concordância e mudanças de direção com redução da seção transversal em ângulos vivos. / The Álvaro Chaves Penstock System (ACP) is the greater storm sewer device of Porto Alegre (Brazil), it was built between 2005 and 2008 and aims to overcome recurrent floods in main avenues located in a highly populated region of 2,8km2. The conception and design of ACP highlight some unusual aspects: the combination of an on-line detention reservoir and a penstock and the reduction of its rectangular cross-sectional area to downstream direction. Moreover, there are abrupt sharp edges contractions (horizontal and vertical), 90° bend with a reduction of rectangular cross-sectional and abrupt geometrical drop. In February 2013, the ACP became notorious because of its structural collapse during a rainstorm event. The precast concrete cover was displaced, soil was removed and the pavement descended. In order to investigate the ACP system, a partial physical model was built in the Instituto de Pesquisas Hidráulicas of the Universidade Federal do Rio Grande do Sul. The geometric scale factor is 1:15, resulting in a 30 m length, variable height (16cm - 42cm) and width (20cm - 50cm). The model reproduces the detention reservoir, its entrances and the short portion of the penstock located downstream of the detention reservoir. The experimental procedure is based is on the propagation of a hydrograph in the conduit. The experimental variables are affluent initial discharge, the overture settings of the downstream discharge valves (both variables affect initial water level in the conduct) and the opening periods of the upstream valves. The data generated during the tests are video images (general camera and high-speed camera) and discharge records. A comprehensive analysis of the images led the identification of tree basic patterns of pipe filling. Pattern A – Filling without air entrapment in quasi-steady state: observed during tests with most favorable drainage conditions, resulting in lower initial water levels in the conduct, given an initial discharge. This pattern represents situations where the Guaíba River level is lower, allowing better drainage capacity. Pattern B – Filling with air entrapment in quasi-steady state: established considering drainage conditions a little bit more restrictives than in Pattern A, resulting in higher initial levels in the conduct for the same affluent discharges. Situations of higher levels in the Guaiba River may be associated with this pattern. Pattern C – Filling with air entrapment in unsteady state: established under the most adverse drainage conditions, resulting in higher initial water level even for very low initial affluent discharges. This pattern represents the most extreme conditions tested, whether in relation to the associated levels of the Guaiba River and in relation to the severity of the observed effects. Furthermore, numerous phenomena and hydraulic instabilities were observed: transition between free surface and pressurized flow, moving hydraulic jumps, entrapment of air pockets, oscillatory waves and translational waves. In general, the ACP model allows the study of the flow in a storm sewer system under unsteady state, considering its singularities: bends, horizontal and vertical contraction without alignment and direction changes with reduction of the cross section sharp angles.
3

Identificação de instabilidades hidráulicas em sistema de drenagem urbana : investigação experimental do conduto forçado Álvaro Chaves

Silva, Juliana Kaiber da January 2015 (has links)
O Conduto Forçado Álvaro Chaves (CFAC), grande obra de drenagem urbana realizada na cidade de Porto Alegre (Brasil) e implantado entre 2005 e 2008, para amenizar alagamentos em ruas e avenidas de uma região altamente populosa, com cerca de 2,8km2. A concepção e dimensionamento do CFAC chamam atenção por alguns aspectos pouco usuais: um reservatório de detenção e um conduto forçado combinados na mesma estrutura e seção transversal retangular, diminuindo de montante para jusante. Além disso, também apresenta contrações verticais e horizontais sem concordâncias apropriadas, desnível geométrico abrupto e mudança de direção em ângulos vivos com diminuição da seção transversal. Esse sistema de drenagem deságua no Rio Guaíba. Em fevereiro de 2013, o CFAC ganhou notoriedade, devido ao colapso de parte de sua estrutura durante um forte evento chuvoso. A cobertura de concreto armado do CFAC foi deslocada e o solo removido, causando o afundamento do pavimento. Para investigar o CFAC, um modelo de detalhe em escala reduzida foi construído no Pavilhão Fluvial do Instituto de Pesquisas Hidráulicas da Universidade Federal do Rio Grande do Sul. A escala de redução geométrica adotada é de 1:15, resultando em um modelo de 30 m de comprimento, com alturas (16 – 42 cm) e larguras variáveis (20 – 50 cm). O modelo reproduz o reservatório de detenção, suas duas entradas e parte do conduto forçado à jusante do reservatório de detenção. O procedimento experimental baseia-se na propagação de um hidrograma no interior do conduto. As variáveis experimentais são a vazão afluente inicial, a configuração de abertura dos registros de jusante (essas duas variáveis condicionam o nível d’água inicial) e o tempo de abertura dos registros de montante. Os principais dados, gerados nos ensaios, são imagens obtidas em vídeo (câmeras normais e câmera rápida) e registros de vazão. A minuciosa análise das imagens permitiu o estabelecimento de três padrões de enchimento do conduto, apresentados a seguir. Padrão A – Enchimento do conduto sem aprisionamento de bolsões de ar e pressurização quasi-steady: observado em ensaios em que as condições de drenagem são mais favoráveis, resultando nos menores níveis iniciais de água no interior do conduto, dada uma vazão afluente. Esse padrão representa situações em que o nível do Rio Guaíba está mais baixo, permitindo maior capacidade de drenagem do sistema. Padrão B – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização quasi-steady: estabelece-se, mediante condições de drenagem um pouco mais restritivas do que no Padrão A, resultando em maiores níveis iniciais para as mesmas vazões afluentes. Situações em que o nível do Rio Guaíba encontra-se mais elevado podem ser associadas a esse padrão. Padrão C – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização unsteady: as condições de drenagem mais adversas condicionam o estabelecimento do Padrão C e resultam em altos níveis iniciais, mesmo para vazões iniciais bastante baixas. Esse padrão representa as condições mais extremas ensaiadas, seja em relação aos níveis do Rio Guaíba associados, seja em relação à severidade das consequências observadas. Além disso, inúmeros fenômenos e instabilidades hidráulicas foram observados: transição entre o escoamento à superfície livre e pressurizado, ressaltos hidráulicos móveis, aprisionamento e movimentação de bolsões de ar, ondas oscilatórias e ondas de translação. De uma maneira geral, o modelo do CFAC permite o estudo do escoamento, em regime não permanente, em um sistema de drenagem urbana que apresenta diversas singularidades, como curvas, contrações horizontais e verticais sem concordância e mudanças de direção com redução da seção transversal em ângulos vivos. / The Álvaro Chaves Penstock System (ACP) is the greater storm sewer device of Porto Alegre (Brazil), it was built between 2005 and 2008 and aims to overcome recurrent floods in main avenues located in a highly populated region of 2,8km2. The conception and design of ACP highlight some unusual aspects: the combination of an on-line detention reservoir and a penstock and the reduction of its rectangular cross-sectional area to downstream direction. Moreover, there are abrupt sharp edges contractions (horizontal and vertical), 90° bend with a reduction of rectangular cross-sectional and abrupt geometrical drop. In February 2013, the ACP became notorious because of its structural collapse during a rainstorm event. The precast concrete cover was displaced, soil was removed and the pavement descended. In order to investigate the ACP system, a partial physical model was built in the Instituto de Pesquisas Hidráulicas of the Universidade Federal do Rio Grande do Sul. The geometric scale factor is 1:15, resulting in a 30 m length, variable height (16cm - 42cm) and width (20cm - 50cm). The model reproduces the detention reservoir, its entrances and the short portion of the penstock located downstream of the detention reservoir. The experimental procedure is based is on the propagation of a hydrograph in the conduit. The experimental variables are affluent initial discharge, the overture settings of the downstream discharge valves (both variables affect initial water level in the conduct) and the opening periods of the upstream valves. The data generated during the tests are video images (general camera and high-speed camera) and discharge records. A comprehensive analysis of the images led the identification of tree basic patterns of pipe filling. Pattern A – Filling without air entrapment in quasi-steady state: observed during tests with most favorable drainage conditions, resulting in lower initial water levels in the conduct, given an initial discharge. This pattern represents situations where the Guaíba River level is lower, allowing better drainage capacity. Pattern B – Filling with air entrapment in quasi-steady state: established considering drainage conditions a little bit more restrictives than in Pattern A, resulting in higher initial levels in the conduct for the same affluent discharges. Situations of higher levels in the Guaiba River may be associated with this pattern. Pattern C – Filling with air entrapment in unsteady state: established under the most adverse drainage conditions, resulting in higher initial water level even for very low initial affluent discharges. This pattern represents the most extreme conditions tested, whether in relation to the associated levels of the Guaiba River and in relation to the severity of the observed effects. Furthermore, numerous phenomena and hydraulic instabilities were observed: transition between free surface and pressurized flow, moving hydraulic jumps, entrapment of air pockets, oscillatory waves and translational waves. In general, the ACP model allows the study of the flow in a storm sewer system under unsteady state, considering its singularities: bends, horizontal and vertical contraction without alignment and direction changes with reduction of the cross section sharp angles.
4

Identificação de instabilidades hidráulicas em sistema de drenagem urbana : investigação experimental do conduto forçado Álvaro Chaves

Silva, Juliana Kaiber da January 2015 (has links)
O Conduto Forçado Álvaro Chaves (CFAC), grande obra de drenagem urbana realizada na cidade de Porto Alegre (Brasil) e implantado entre 2005 e 2008, para amenizar alagamentos em ruas e avenidas de uma região altamente populosa, com cerca de 2,8km2. A concepção e dimensionamento do CFAC chamam atenção por alguns aspectos pouco usuais: um reservatório de detenção e um conduto forçado combinados na mesma estrutura e seção transversal retangular, diminuindo de montante para jusante. Além disso, também apresenta contrações verticais e horizontais sem concordâncias apropriadas, desnível geométrico abrupto e mudança de direção em ângulos vivos com diminuição da seção transversal. Esse sistema de drenagem deságua no Rio Guaíba. Em fevereiro de 2013, o CFAC ganhou notoriedade, devido ao colapso de parte de sua estrutura durante um forte evento chuvoso. A cobertura de concreto armado do CFAC foi deslocada e o solo removido, causando o afundamento do pavimento. Para investigar o CFAC, um modelo de detalhe em escala reduzida foi construído no Pavilhão Fluvial do Instituto de Pesquisas Hidráulicas da Universidade Federal do Rio Grande do Sul. A escala de redução geométrica adotada é de 1:15, resultando em um modelo de 30 m de comprimento, com alturas (16 – 42 cm) e larguras variáveis (20 – 50 cm). O modelo reproduz o reservatório de detenção, suas duas entradas e parte do conduto forçado à jusante do reservatório de detenção. O procedimento experimental baseia-se na propagação de um hidrograma no interior do conduto. As variáveis experimentais são a vazão afluente inicial, a configuração de abertura dos registros de jusante (essas duas variáveis condicionam o nível d’água inicial) e o tempo de abertura dos registros de montante. Os principais dados, gerados nos ensaios, são imagens obtidas em vídeo (câmeras normais e câmera rápida) e registros de vazão. A minuciosa análise das imagens permitiu o estabelecimento de três padrões de enchimento do conduto, apresentados a seguir. Padrão A – Enchimento do conduto sem aprisionamento de bolsões de ar e pressurização quasi-steady: observado em ensaios em que as condições de drenagem são mais favoráveis, resultando nos menores níveis iniciais de água no interior do conduto, dada uma vazão afluente. Esse padrão representa situações em que o nível do Rio Guaíba está mais baixo, permitindo maior capacidade de drenagem do sistema. Padrão B – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização quasi-steady: estabelece-se, mediante condições de drenagem um pouco mais restritivas do que no Padrão A, resultando em maiores níveis iniciais para as mesmas vazões afluentes. Situações em que o nível do Rio Guaíba encontra-se mais elevado podem ser associadas a esse padrão. Padrão C – Enchimento do conduto com aprisionamento de bolsões de ar e pressurização unsteady: as condições de drenagem mais adversas condicionam o estabelecimento do Padrão C e resultam em altos níveis iniciais, mesmo para vazões iniciais bastante baixas. Esse padrão representa as condições mais extremas ensaiadas, seja em relação aos níveis do Rio Guaíba associados, seja em relação à severidade das consequências observadas. Além disso, inúmeros fenômenos e instabilidades hidráulicas foram observados: transição entre o escoamento à superfície livre e pressurizado, ressaltos hidráulicos móveis, aprisionamento e movimentação de bolsões de ar, ondas oscilatórias e ondas de translação. De uma maneira geral, o modelo do CFAC permite o estudo do escoamento, em regime não permanente, em um sistema de drenagem urbana que apresenta diversas singularidades, como curvas, contrações horizontais e verticais sem concordância e mudanças de direção com redução da seção transversal em ângulos vivos. / The Álvaro Chaves Penstock System (ACP) is the greater storm sewer device of Porto Alegre (Brazil), it was built between 2005 and 2008 and aims to overcome recurrent floods in main avenues located in a highly populated region of 2,8km2. The conception and design of ACP highlight some unusual aspects: the combination of an on-line detention reservoir and a penstock and the reduction of its rectangular cross-sectional area to downstream direction. Moreover, there are abrupt sharp edges contractions (horizontal and vertical), 90° bend with a reduction of rectangular cross-sectional and abrupt geometrical drop. In February 2013, the ACP became notorious because of its structural collapse during a rainstorm event. The precast concrete cover was displaced, soil was removed and the pavement descended. In order to investigate the ACP system, a partial physical model was built in the Instituto de Pesquisas Hidráulicas of the Universidade Federal do Rio Grande do Sul. The geometric scale factor is 1:15, resulting in a 30 m length, variable height (16cm - 42cm) and width (20cm - 50cm). The model reproduces the detention reservoir, its entrances and the short portion of the penstock located downstream of the detention reservoir. The experimental procedure is based is on the propagation of a hydrograph in the conduit. The experimental variables are affluent initial discharge, the overture settings of the downstream discharge valves (both variables affect initial water level in the conduct) and the opening periods of the upstream valves. The data generated during the tests are video images (general camera and high-speed camera) and discharge records. A comprehensive analysis of the images led the identification of tree basic patterns of pipe filling. Pattern A – Filling without air entrapment in quasi-steady state: observed during tests with most favorable drainage conditions, resulting in lower initial water levels in the conduct, given an initial discharge. This pattern represents situations where the Guaíba River level is lower, allowing better drainage capacity. Pattern B – Filling with air entrapment in quasi-steady state: established considering drainage conditions a little bit more restrictives than in Pattern A, resulting in higher initial levels in the conduct for the same affluent discharges. Situations of higher levels in the Guaiba River may be associated with this pattern. Pattern C – Filling with air entrapment in unsteady state: established under the most adverse drainage conditions, resulting in higher initial water level even for very low initial affluent discharges. This pattern represents the most extreme conditions tested, whether in relation to the associated levels of the Guaiba River and in relation to the severity of the observed effects. Furthermore, numerous phenomena and hydraulic instabilities were observed: transition between free surface and pressurized flow, moving hydraulic jumps, entrapment of air pockets, oscillatory waves and translational waves. In general, the ACP model allows the study of the flow in a storm sewer system under unsteady state, considering its singularities: bends, horizontal and vertical contraction without alignment and direction changes with reduction of the cross section sharp angles.
5

Análise paramétrica do comportamento de condutos enterrados flexíveis e de grande diâmetro

Kênia Damasceno Silveira 19 December 2001 (has links)
Neste trabalho apresenta-se uma análise paramétrica de um sistema composto por cinco condutos flexíveis enterrados, paralelos e de grande diâmetro. Analisou-se o comportamento dessas estruturas em relação à altura de cobertura do aterro, à posição de atuação de cargas externas, ao espaçamento horizontal entre condutos e aos parâmetros geotécnicos do solo, tais como, módulo de elasticidade, ângulo de atrito, coesão e grau de compactação. Para a realização das análise utilizou-se o programa SSCOMPPC (BOULANGER et al, 1991) baseado no método dos elementos finitos (MEF). Implementou-se em Visual Basic um pré/pós-processador com o intuito de facilitar a entrada de dados, a geração da malha, bem como, a visualização dos deslocamentos e dos esforços finais no conduto. Os resultados obtidos revelam que os momentos fletores atuantes são mais críticos no topo e nos ombros das estruturas quando estas estão sujeitas a cargas de tráfego. O deslocamento crítico ocorre no topo das estruturas de maiores vãos. Quanto à atuação das tensões verticais, devido ao peso próprio do aterro e às cargas de tráfego, estas são totalmente dissipadas no solo para alturas de cobertura de aterro superiores a 3,0m. Além disto, a estabilidade dos condutos instalados é proporcional ao grau de compactação e ao módulo de elasticidade do solo. A variação dos parâmetros de resistência do solo apontou a coesão como um fator muito significativo no comportamento das estruturas
6

Modelo computacional para análise de transiente hidráulico em canais / Computational model for the study unsteady open-channel flows

Venâncio, Stênio de Sousa 03 July 2003 (has links)
Este trabalho representa a continuidade de estudos envolvendo a problemática dos escoamentos com superfície livre, contemplando a análise do fenômeno transiente em canais, a partir do modelo matemático unidimensional de Saint-Venant. Para tanto, é desenvolvido um modelo computacional em linguagem FORTRAN, capaz de avaliar o comportamento do escoamento não permanente. As equações hidrodinâmicas completas são discretizadas por um esquema completamente implícito de diferenças finitas e aplicadas no modelo computacional para a avaliação de dois casos. O modelo é previamente testado para um caso simples, cujos resultados são analisados viabilizando o modelo. No primeiro caso, o modelo é aplicado ao canal de alimentação da Usina Hidrelétrica Monjolinho em São Carlos-SP, para avaliar a necessidade de vertedouro quando se dá o fechamento brusco da turbina, e a ocorrência da entrada de ar na mesma quando da sua abertura repentina. No segundo caso, procurou-se avaliar o desenvolvimento do escoamento no Canal do Trabalhador, responsável pelo abastecimento da cidade de Fortaleza-CE. Com manobras de enchimento e esvaziamento do sistema, é possível determinar o tempo de antecedência de liga-desliga do sistema de recalque a partir das alturas dágua e velocidades de ocorrência, permitindo também a automação para as operações de controle. Em ambos os casos o modelo reproduziu resultados que ilustram com coerência os conceitos pré-estabelecidos, constituindo numa ferramenta útil para análise do fenômeno transiente nos escoamentos em condutos livres. / This work presents a computational model developed in FORTRAN language for the study of unsteady open-channel flows with the use of Saint-Venant one-dimensional equation. The discretization of hydrodynamic equations are presented in a completely implicit method of finite differences and applied in the model for the investigation of two cases, besides the one used previously to test the model. In the first case, the model is applied for a channel that supplies the Monjolinho hydroelectric plant in Sao Carlos SP, aiming to evaluate the need of a spillway when the turbine is closed and the flow abruptly stopped, as well as the occurrence of air entering the turbine when it is opened instantaneously. In the second case, the model simulates the development of the flow in the Trabalhador channel, responsible for the water supply in the city of Fortaleza - CE, in order to make possible the automation of operational control, based on data of flow velocity and water level. In both cases the model is presented as a useful tool for the analysis of unsteady open-channel flows, showing results and coherency with theory.
7

CARACTERÍSTICAS AUDIOLÓGICAS DE INDIVÍDUOS NORMO-OUVINTES COM QUEIXAS DE ZUMBIDO E HIPERACUSIA / AUDIOLOGICAL CHARACTERISTICS IN NORMAL HEARING SUBJECTS WITH COMPLAINTS OF TINNITUS AND HYPERACUSIS

Urnau, Daila 02 March 2011 (has links)
OBJECTIVES: to verify the occurrence and the effect of transient otoacoustic emissions (TEOAE), existence of association between: tinnitus degrees and hyperacusis degrees, TEOAE suppressive effect and laterality, tinnitus and hyperacusis degrees, and verify the characteristics of normal hearing individuals with complaints of tinnitus and hyperacusis. MATERIALS AND METHODS: The study included 25 normal hearing subjects having complaints of tinnitus and hyperacusis, with 16 female and nine male. About tinnitus, the subjects were asked about the location and tinnitus type and they completed the Tinnitus Handicap Inventory (THI), used for the classification of tinnitus degrees. A developed hyperacusis questionnaire and the questionnaire on handedness The assessment and analysis of handedness: The Edinburgh Inventor were completed too. They were tested about the research of Loudness Discomfort Level (degrees of hyperacusis), Acuphenometry and the suppression effect of otoacoustic emissions (TEOAE) in the frequencies of 1, 1.5, 2, 3 and 4 KHz. We used descriptive and statistical analysis of the data (Fisher exact test, Kruskal Wallis and Mann Whitney U and Spearman correlation). RESULTS: The occurrence of TEOAE ranged from 33 to 88%. We observed the presence of TEOAE suppression effect on 63.7% in the right ear and 81.7% in the left ear. There was no association between tinnitus degrees and hyperacusis degrees, and between the TEOAE suppression effect and laterality, degrees of tinnitus and hyperacusis degrees. About tinnitus, the most subjects reported acute pitch, in anamnesis and in Acuphenometry, bilateral location and mild degree. Women had degree of tinnitus statistically superior than men. The sounds considered uncomfortable were the high intensity ones and the reaction to the sounds most often cited were irritation, anxiety and need to depart from the sound. The difficulty in speech understanding at noise was mentioned. CONCLUSION: We conclude that the occurrence of TEOAE in these subjects was lower than that found in normal hearing subjects. A higher percentage of presence of TEOAE suppression effect has been found in both ears. Degrees of tinnitus and hyperacusis degrees were not correlated in normal-hearing individuals with complaints of tinnitus and hyperacusis, and there was no association between the TEOAE suppression effect and laterality and degrees of tinnitus and hyperacusis. The sample presented acute pitch, bilateral location and mild bilateral tinnitus.High intensity sounds were reported as uncomfortable and irritation was the most cited reaction of the sound. / OBJETIVO: verificar a ocorrência e o efeito de supressão das emissões otoacústicas transientes (EOAT), a existência de associação entre: graus de zumbido e de hiperacusia, efeito supressor das EOAT e lateralidade, graus de zumbido e graus de hiperacusia, e analisar as características audiológicas de indivíduos normo-ouvintes com queixas de zumbido e hiperacusia. MATERIAIS E MÉTODOS: A amostra foi composta por 25 indivíduos normo-ouvintes, com queixas de zumbido e hiperacusia, sendo 16 do gênero feminino e nove do masculino. Em relação ao zumbido, os indivíduos foram questionados sobre o pitch e localização e preencheram o Tinnitus Handicap Inventory brasileiro (THI), utilizado para avaliar o grau de zumbido. O questionário de hiperacusia e o questionário sobre lateralidade manual The assessment and analysis of handedness: The Edinburgh Inventory também foram preenchidos. Os indivíduos foram submetidos a pesquisa do Loudness Discomfort Level (grau de hiperacusia), a acufenometria e a pesquisa e do efeito de supressão das emissões otoacústicas transientes (EOATs) nas frequências de 1, 1,5, 2, 3 e 4 KHz. Utilizou-se análise descritiva e estatística dos dados (testes exato de Fisher, Kruskal Wallis, U de Man Whitney e correlação de Spearman). RESULTADOS: A ocorrência das EOAT variou de 33 a 88%. Houve 63,7% de presença de efeito de supressão na orelha direita e 81,7% na orelha esquerda. Não ocorreu associação significativa entre os graus de zumbido e os graus de hiperacusia, e entre o efeito supressor das EOAT e lateralidade, graus de zumbido e graus de hiperacusia. Em relação ao zumbido, a maioria dos indivíduos apresentou pitch agudo, tanto na anamnese quanto na acufenometria, localização bilateral e grau leve no THI. As mulheres apresentaram grau de zumbido estatisticamente superior ao dos homens. Os sons considerados desconfortáveis foram os de alta intensidade e as reações aos sons mais citadas foram a irritação, ansiedade e necessidade de afastar-se do som. A dificuldade de compreensão de fala na presença de ruído foi referida pela maioria dos indivíduos.CONCLUSÃO: Conclui-se que a ocorrência de EOAT foi inferior a encontrada em sujeitos normo-ouvintes sem esses sintomas. Obteve-se maior percentual de presença do efeito de supressão das EOATs em ambas as orelhas analisadas. Os graus de zumbido e os graus de hiperacusia não apresentaram correlação em indivíduos normo-ouvintes com queixas de zumbido e hiperacusia, bem como não ocorreu associação entre o efeito de supressão das EOAT e lateralidade, graus de zumbido e de hiperacusia. A amostra estudada apresentou predomínio de zumbido de pitch agudo, localização bilateral e grau leve. Os sons considerados desconfortáveis foram os de alta intensidade e a reação de irritação aos sons foi a mais citada.
8

Modelo computacional para análise de transiente hidráulico em canais / Computational model for the study unsteady open-channel flows

Stênio de Sousa Venâncio 03 July 2003 (has links)
Este trabalho representa a continuidade de estudos envolvendo a problemática dos escoamentos com superfície livre, contemplando a análise do fenômeno transiente em canais, a partir do modelo matemático unidimensional de Saint-Venant. Para tanto, é desenvolvido um modelo computacional em linguagem FORTRAN, capaz de avaliar o comportamento do escoamento não permanente. As equações hidrodinâmicas completas são discretizadas por um esquema completamente implícito de diferenças finitas e aplicadas no modelo computacional para a avaliação de dois casos. O modelo é previamente testado para um caso simples, cujos resultados são analisados viabilizando o modelo. No primeiro caso, o modelo é aplicado ao canal de alimentação da Usina Hidrelétrica Monjolinho em São Carlos-SP, para avaliar a necessidade de vertedouro quando se dá o fechamento brusco da turbina, e a ocorrência da entrada de ar na mesma quando da sua abertura repentina. No segundo caso, procurou-se avaliar o desenvolvimento do escoamento no Canal do Trabalhador, responsável pelo abastecimento da cidade de Fortaleza-CE. Com manobras de enchimento e esvaziamento do sistema, é possível determinar o tempo de antecedência de liga-desliga do sistema de recalque a partir das alturas dágua e velocidades de ocorrência, permitindo também a automação para as operações de controle. Em ambos os casos o modelo reproduziu resultados que ilustram com coerência os conceitos pré-estabelecidos, constituindo numa ferramenta útil para análise do fenômeno transiente nos escoamentos em condutos livres. / This work presents a computational model developed in FORTRAN language for the study of unsteady open-channel flows with the use of Saint-Venant one-dimensional equation. The discretization of hydrodynamic equations are presented in a completely implicit method of finite differences and applied in the model for the investigation of two cases, besides the one used previously to test the model. In the first case, the model is applied for a channel that supplies the Monjolinho hydroelectric plant in Sao Carlos SP, aiming to evaluate the need of a spillway when the turbine is closed and the flow abruptly stopped, as well as the occurrence of air entering the turbine when it is opened instantaneously. In the second case, the model simulates the development of the flow in the Trabalhador channel, responsible for the water supply in the city of Fortaleza - CE, in order to make possible the automation of operational control, based on data of flow velocity and water level. In both cases the model is presented as a useful tool for the analysis of unsteady open-channel flows, showing results and coherency with theory.
9

"Estudo das vias auditivas eferentes em indivíduos com zumbido" / Study of efferent auditory pathways in subjects with tinnitus

Favero, Mariana Lopes 30 March 2004 (has links)
Uma ativação do trato olivococlear medial reduz a amplitude das emissões otoacústicas de forma lateralizada, com um predomínio à direita. Pessoas com zumbido teriam uma disfunção do reflexo eferente, mas esses resultados não foram comprovados em todas as pesquisas. Curiosamente, estas pesquisas não valorizam a lateralidade eferente. Comparamos a supressão na orelha direita de pessoas com e sem zumbido e a lateralidade do sistema eferente pela análise da supressão à direita e à esquerda no grupo sem zumbido. Concluímos que há relação entre zumbido e não supressão e que à direita, a supressão é maior / An activation of the medial olivocochlear tract reduces the amplitude of otoacoustic emissions with predominance of the right side. Subjects with tinnitus would have an abnormality of the suppressing reflex, but such results have not been confirmed yet in any study. Curiously, such studies did not value the functional laterality. We compared right ear suppression of people with and without tinnitus, and the suppression on the right and on the left in the group without tinnitus. We concluded that there was a relation between tinnitus and absent suppression of otoacoustic emissions and right ear suppression was more marked.
10

Tubulações enterradas: \"o uso da trincheira induzida\" / Buried pipes: \"the use of induced trench\"

Melotti, Orlando Kannebley 09 August 2002 (has links)
Atualmente a otimização e redução de custos verificados na fabricação de tubulações está caminhando para um limite. Toda e qualquer modificação no processo produtivo exige grandes investimentos com retorno a prazos cada vez maiores. Assim, a possibilidade de poder contar com técnicas que permitam a redução de esforços sobre tubulações enterradas traz sem dúvida uma importante contribuição. Este trabalho estuda o uso da trincheira como forma de reduzir os esforços que atuam sobre condutos enterrados, utilizando duas séries de ensaios denominados \"A\" e \"B\". Cada série é composta basicamente de quatro combinações diferentes, com variações geométricas da relação de altura relativa (h/B) e largura relativa (b/B). A série B teve a posição relativa (H/B) da camada flexível modificada em relação à série A. Os ensaios realizados no Departamento de Geotecnia da Escola de Engenharia de São Carlos apresentam como resultado uma redução dos esforços da ordem de 44% a 86% em relação ao ensaio de referência montado sem o uso da camada indutora. / Nowadays the optimization and the reduction of costs verified in the pipes production are walking for a limit. All and whatever modification on the productive process demands great investments with larger time return. Thus, the possibility of taking account with techniques that allows reduction efforts on buried pipes bring without any doubt, an important contribution. This work studies the induced trench to reduce the efforts that act over buried conduits, using two series, \"A\" and \"B\", with four treatments each one. The A series is composed with four different combinations. These combinations have geometric variation between relative height (h/B) and relative width (b/B) of flexible layers, were built directly over the trap door. The \"B\" series is composed with the same geometric flexible layer used in series \"A\", and they have their relative position (H/B) modified. The treatments were conducted at the \"Departamento de Geotecnia\" da \"Escola de Engenharia de São Carlos\". The results obtained were a reduction of the 44 to 86% on the efforts in relation to the reference treatment built without the use of an induced layer.

Page generated in 0.0438 seconds