• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 89
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 94
  • 94
  • 61
  • 48
  • 28
  • 27
  • 15
  • 15
  • 14
  • 12
  • 12
  • 12
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Diagnóstico energético e gestão da energia em uma planta petroquímica de primeira geração : Energy assessments and energy management in a first generation of petrochemical plant / Energy assessments and energy management in a first generation of petrochemical plant

Mathias, Flávio Roberto de Carvalho, 1962- 03 October 2014 (has links)
Orientador: Sérgio Valdir Bajay / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-24T20:32:50Z (GMT). No. of bitstreams: 1 Mathias_FlavioRobertodeCarvalho_M.pdf: 4818388 bytes, checksum: 36fdbf4b64a7624d168033ba881dc333 (MD5) Previous issue date: 2014 / Resumo: A implantação de um eficiente sistema de gestão da energia é um desafio recente para a maior parte das empresas industriais no Brasil. Neste trabalho, os conceitos de diagnósticos energéticos e sua aplicação em sistemas de gestão de energia na indústria são revisados e se propõe diretrizes para o seu emprego em uma unidade petroquímica de insumos básicos da Braskem, a mais antiga no Brasil. Foi calculado um potencial técnico médio de conservação de energia, no período entre 2009 e 2012, de 36,4% para esta unidade. Indicadores de desempenho energético são discutidos e oportunidades de ganhos de eficiência energética nesta unidade são apresentadas para os seguintes usos finais da energia/equipamentos: calor de processo, aquecimento direto, força motriz, sistemas de bombeamento e sistemas de ar comprimido. Um diagnóstico energético realizado nesta unidade em 2012, com a participação do autor desta dissertação, propiciou a detecção destas oportunidades. As propostas que visam à obtenção de avanços no atual sistema de gestão energética desta unidade da Braskem tem como balizadores o princípio de desenvolvimento empresarial sustentável e a perspectiva de um credenciamento futuro do sistema de gestão da energia pela norma ISO 50.001 / Abstract: Setting-up an efficient energy management system is a recent challenge for most of the industrial companies in Brazil. The concepts of energy assessments and their application in industrial energy management systems are reviewed in this work and directives are proposed for they use in a petrochemical unit of Braskem that produces basic chemicals, the oldest in Brazil. An average technical energy conservation potential of 36.4% during the period between 2009 and 2012 was calculated for this unit. Energy performance indicators are discussed and opportunities for energy efficiency gains in this unit are presented for the following energy end-uses/equipment: process heat, including steam systems and furnaces/chemical reactors, power, pumping systems and compressed air systems. An energy assessment carried out at this plant in 2012, with the participation of this thesis¿ author, provided the chance for detecting these opportunities. The proposals aiming at obtaining advances in the current energy management system at this unit of Braskem are guided by the principle of a sustainable corporate development and by the perspective of a future certification of the plant¿s energy management system by the ISO 50.001 standard / Mestrado / Planejamento de Sistemas Energeticos / Mestre em Planejamento de Sistemas Energéticos
62

Gestão da energia na indústria de laticínios / Energy management in dairy industries

Silva, Paulo César, 1973- 06 May 2014 (has links)
Orientador: Sérgio Valdir Bajay / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-25T18:33:48Z (GMT). No. of bitstreams: 1 Silva_PauloCesar_M.pdf: 13836240 bytes, checksum: d17a0ef5a849b2017ccd2577d7c006b4 (MD5) Previous issue date: 2014 / Resumo: O segmento de alimentos e bebidas é responsável pelo maior consumo energético do setor industrial no Brasil. Este trabalho apresenta um Sistema de Gestão da Energia (SGE) implantado com sucesso em uma fábrica de laticínios. O SGE em questão foi implantado a partir do ano de 2005, na fábrica da Danone, empresa multinacional de origem francesa, localizada na cidade de Poços de Caldas ¿ MG. O SGE aqui descrito passou por várias modificações na busca por melhorias, que proporcionaram uma substancial redução no consumo energético específico da fábrica, acima de 38% entre os anos de 2005 (521 kWh/ton) e 2012 (320 kWh/ton). O autor deste trabalho, que também é funcionário da empresa e atua a nível global como um dos responsáveis pela gestão da energia na Danone, relata várias medidas de eficiência energética usualmente adotadas na indústria de laticínios e descreve as principais medidas implementadas na fábrica da Danone em Poços de Caldas, algumas delas durante a realização do curso de mestrado em Planejamento de Sistemas Energéticos. A dissertação aborda as várias etapas requeridas para se estruturar um SGE e como elas foram implantadas na fábrica em questão. Para melhorar a atual estrutura do SGE da fábrica de Poços de Caldas são propostas, na dissertação, várias novas ações, dentre as quais se destaca a implantação de um sistema automatizado e padronizado pela Companhia a nível global. Como recomendação final é proposta a padronização do SGE dessa fábrica pela norma ISO 50001 / Abstract: The food and beverage segment is responsible for the highest energy consumption in the industrial sector in Brazil. This paper presents an Energy Management System (EMS) successfully implanted in a dairy plant. The EMS in question was implemented from the year 2005, at Danone, a multinational company of French origin, located in Poços de Caldas - MG. The EMS described here has gone through several changes in the search for improvements, which provided a substantial reduction in specific energy consumption of the plant, over 38% between 2005 (521 kWh/ton) and 2012 (320 kWh/ton). The author of this dissertation, which is also an employee of the company and operates globally as one of those responsible for managing energy in Danone Group reports various energy efficiency measures usually adopted in the dairy industry and describes the main measures implemented in the Danone factory in Poços de Caldas, some of them during the master course in Energy Systems Planning. The dissertation discusses the various steps required to design an EMS and how they were implemented in the plant. To improve the current structure of the EMS in Poços de Caldas plant are proposed in the dissertation, several new activities, among which stands out the deployment of an automated and standardized worldwide by Company. One final recommendation proposed is the standardization of this plant by ISO 50001 / Mestrado / Planejamento de Sistemas Energeticos / Mestre em Planejamento de Sistemas Energéticos
63

Uso racional e eficiente de energia elétrica: metodologia para determinação dos potenciais de conservação dos usos finais em instalações de ensino e similares. / Methodology for determining the potential of electric energy conservation of electricity end uses in university buildings.

Alvarez, André Luiz Montero 22 April 1998 (has links)
Este trabalho apresenta uma metodologia para a determinação do potencial de conservação de energia elétrica de usos finais, orientada para a análise de instalações de ensino, aplicável, também, a instalações comerciais em geral. Os usos finais considerados no trabalho são: iluminação, ar condicionado, microcomputadores pessoais e outros equipamentos elétricos. São apresentados procedimentos para o levantamento de dados e para a determinação do potencial de conservação de energia elétrica de cada uso final analisado, além de uma metodologia estatística para a análise de contas de energia elétrica. São definidos, também, indicadores do uso de energia elétrica bastante úteis em diagnósticos energéticos, permitindo estimar o potencial de conservação da instalação a partir da análise comparativa de seus índices com valores típicos obtidos em outros diagnósticos energéticos ou em publicações especializadas. A aplicação prática da metodologia é apresentada na forma de um estudo de caso, realizado em 1996 na Cidade Universitária Armando de Salles Oliveira - CUASO, o maior campus da Universidade de São Paulo – USP e um dos maiores do Brasil, localizado na cidade de São Paulo. Um volume considerável de informações é analisado e discutido em detalhes, fornecendo dados globais e desagregados em usos finais sobre as características de consumo e os potenciais de conservação de energia elétrica do campus. / This work presents a methodology for determining the potential of electric energy conservation of electricity end uses. The methodology is oriented to university premises, but it is also applicable to other types of installations. End uses considered in this work include lighting, air conditioning, personal computers and other electric devices. Procedures for data gathering and determination of conservation potential of each end use are presented. A statistical methodology for analyzing electricity bills is also presented. Furthermore, some useful indicators for energy diagnoses are developed. These indicators allow the estimation of the conservation potential of a given installation through comparison with typical values extracted from the other energy diagnoses or technical literature. The proposed methodology was applied in the main campus of University of São Paulo – USP, one of the largest in Brazil with some 30,000 undergraduate students. A large amount of data is analyzed and discussed, yielding global and specific indicators regarding end use characteristics and conservation potential within the campus.
64

Metodologia para avaliação e otimização de motores elétricos de indução trifásicos visando a conservação de energia em aplicações industriais / Methodology for evaluation and optimization of three-phase induction motors to promote the conservation of energy in industrial applications.

Ramos, Mario Cesar do Espirito Santo 29 October 2009 (has links)
Esta tese apresenta uma metodologia específica para a quantificação das perdas energéticas em motores elétricos de indução trifásicos com rotor em gaiola, por meio da determinação indireta do rendimento nas condições de funcionamento a plena carga. A referida metodologia, denominada MHmit, foi desenvolvida em ambientes industriais, particularmente no segmento alimentício, contando também com a colaboração do Laboratório de Máquinas Elétricas do Instituto de Eletrotécnica e Energia da Universidade de São Paulo no tocante a disponibilização dos ensaios de vários motores de indução trifásicos com rotor em gaiola ao longo de vários anos de prestação de serviços. Esses ensaios foram de extrema importância para a validação da metodologia apresentada. Sendo o motor elétrico um equipamento de uso final de forte presença industrial, é passível de substituição por tecnologias mais eficientes mediante a realização de estudos de eficiência energética. Os diagnósticos energéticos em sistemas motrizes beneficiam as indústrias por meio da diminuição dos custos com energia elétrica, tanto pela redução de demanda, quanto pela redução do consumo. Porém, para o desenvolvimento desta metodologia foi necessária a avaliação de estudos realizados por empresas prestadoras de serviços na área de conservação de energia elétrica. Essas empresas foram selecionadas a partir da averiguação da satisfação do cliente quanto aos serviços prestados e resultados obtidos após a substituição dos motores. Por meio da análise de 266 casos, verificaram-se os problemas encontrados por essas empresas antes, durante e após a substituição dos motores elétricos do tipo padrão por de alto rendimento. Em alguns casos, a substituição de um motor antigo do tipo padrão por um motor novo do tipo alto rendimento resultou num aumento do consumo de energia elétrica, fato este totalmente controverso quando se espera uma economia de 2 a 6% proveniente desta mudança de tecnologias, de acordo com Eletrobrás e NEMA MG 1. A metodologia MHmit desenvolvida neste trabalho contempla esta situação. As principais metodologias atualmente utilizadas na realização de estudos para substituição de motores elétricos dos tipos padrão por alto rendimento foram analisadas e apresentadas neste trabalho. Dentre elas, a metodologia convencional, que utiliza curvas de motores elétricos para a determinação do rendimento, a metodologia que utiliza o programa denominado BD Motor, desenvolvido pelo Centro de Pesquisas em Energia Elétrica da Eletrobrás, a VII metodologia que utiliza o programa Mark IV, desenvolvido por pesquisadores da Universidade Federal de Itajubá, em parceria com o Procel / Eletrobrás e o software Motor Master, desenvolvido pelo Departamento de Energia Norte-Americano (DoE). Todos esses programas estão disponíveis gratuitamente para download no site do Procel Info / Eletrobrás - www.procelinfo.com.br. A metodologia MHmit, desenvolvida neste trabalho, apresentou desvios percentuais satisfatórios (10,12%) entre os valores previstos (durante as simulações com o aplicativo MHmit) e reais (por meio da verificação da real economia de energia elétrica proporcionada após a substituição do novo motor) das metodologias em estudo. Estas, não contemplam dados de parâmetros de motores antigos, dificultando a obtenção de um valor verdadeiro do rendimento do motor em funcionamento, pois muitas vezes este já sofreu reparos, rebobinagens e curtos-circuitos. Os 86 estudos de caso realizados para a validação desta metodologia (motores com potências de 7,5 a 125 cv) mostraram diferenças significativas entre os valores previstos pelas metodologias atuais e a metodologia desenvolvida MHmit. / This thesis presents a specific methodology to quantify the energy loss in three-phase induction electric motors with cage rotor, by indirect determination of efficiency under operation conditions at full load. This methodology, named MHmit, was developed in industrial environments, particularly in textile and food sectors, relying on the collaboration of the machines laboratory of the Institute of Electrotechnics and Energy, University of São Paulo on the availability of tests in several three-phase induction motors with cage rotor over several years under the laboratory service. These essays were extremely important to validate the presented methodology. Once the electric motor is an equipment of final use strongly present in industry, it is subject to replacement by more efficient technologies by carrying out energy efficiency studies. Energy Diagnosis in electric motors aims to provide the client with a decrease in electric energy costs, not only a decrease in demand, but also as a decrease in consumption. However, for the development of this methodology, it was necessary for evaluation, an assessment by companies that provide services in the area of energy conservation. These companies were selected from an investigation of customer satisfaction on services provided and results obtained after replacing the motors. By analyzing 266 cases, the problems found by these companies had been verified before, during and after the substitution of standard electric motors by high-efficiency ones. In some cases, the substitution of an old standard motor by a new high-efficiency one resulted in an increase of consumption of electric energy, and this fact is totally controversial when one expects savings of 2 to 6 % from this change of technologies, according to Eletrobrás and NEMA MG 1. The methodology MHmit developed in this work covers this situation. The main methodologies currently used to carry out studies to replace standard electric motors by high-efficiency ones were analyzed and presented in this work. Amongst them, the conventional methodology, which uses electric motor curves to determine efficiency, and the methodology that uses the program named BD Motor, developed by the Center of Research in Electric Energy of Eletrobrás, the methodology that uses the program Mark IV, developed by researchers from Federal University of Itajubá, in partnership with Procel/Eletrobrás and the IX program named Motor Master, developed by the North American Department of Energy (DoE). All these programs are freely available for download at Procel Info/Eletrobrás website - www.procelinfo.com.br. The MHmit methodology, developed in this work, presented satisfactory percentage values of deviations (10,12%), between the predicted values (during simulations with MHmit application) and real (by checking the real electric energy savings provided after the old standard motor replacement) when compared to the methodologies in study. These, do not include the old motor data parameters, making it difficult to obtain a true value of motor operation efficiency, because it may have gone through repairs, rewinding and short-circuits. The 86 case studies which were carried out for the validation of this methodology (motors with rated power from 7.5 to 125 hp) showed significant differences between the values provided by current methodologies and the methodology developed MHmit.
65

Iluminação natural em projetos de escolas: uma proposta de metodologia para melhorar a qualidade da iluminação e conservar energia / Daylighting in schools projects: a proposition of a methodology to enhance lighting quality and energy savings.

Bertolotti, Dimas 18 April 2007 (has links)
Este trabalho tem como objetivo analisar estratégias de iluminação natural utilizadas nos estágios iniciais do projeto de arquitetura capazes de aumentar a qualidade da iluminação e a conservação de energia nos edifícios escolares. Essas estratégias têm sido aplicadas com sucesso em edifícios escolares em vários países, melhorando o desempenho e o bem-estar dos estudantes e conservando energia. Entre essas estratégias, o autor selecionou um dispositivo zenital para iluminação natural com seleção angular e difusores opacos, realizou um ensaio experimental em um modelo físico reduzido de uma sala de aula padrão, sob condições de céu real e analisou comparativamente os resultados. O estudo mostrou que a adoção de uma metodologia para utilizar estratégias como a analisada neste trabalho pode conseguir um adequado controle da radiação solar para evitar a incidência direta da luz do Sol, evitar o ofuscamento e o aquecimento excessivo de ambientes de salas de aula em climas quentes e, ao mesmo tempo, aproveitar a iluminação natural, tanto difusa quanto direta refletida, para obter maior conforto visual e economizar energia. / This work aims to analyse daylighting strategies applied in early stages of architectural design as to improve lighting quality and energy savings in school buildings. Similar strategies have already been successfully applied in many countries around the world, enhancing student?s performance and well being while helping to save energy. Among the strategies studied, the author describes an experiment under real sky conditions using a physical scale model of a standard classroom equipped with a roof monitor combined with an overhang and interior vertical diffusing baffles as a way to check its influence in interior lighting conditions. The experiment has shown that the use of daylighting strategies can promote an adequate control of solar radiation, avoiding direct sunlight penetration inside the classrooms, limiting glare problems and excessive heat of hot climates. At the same time, such strategies optimise both direct and defuse use of daylight to improve visual comfort and energy savings.
66

Sistema de ar condicionado com insuflamento pelo piso em ambientes de escritórios: avaliação do conforto térmico e condições de operação. / Underfloor air supply system applied to office buildings: thermal comfort and operational conditions evaluation.

Leite, Brenda Chaves Coelho 06 March 2003 (has links)
Desde a introdução do conceito de escritório aberto, o tipo de ocupação e a distribuição das cargas internas têm sofrido grandes mudanças, requerendo maior flexibilidade nos edifícios. Além disto, avaliações de desempenho de edifícios de escritórios da atualidade têm apresentado resultados que são fortes indicadores da necessidade de mudanças de conceitos de projeto, operação e uso de sistemas de condicionamento de ar, devido ao elevado nível de insatisfação dos usuários quanto ao conforto e à qualidade do ar. Para tentar solucionar estes problemas, outro conceito em distribuição de ar, já em uso nos países desenvolvidos, está começando a ser adotado também no Brasil; trata-se de insuflamento pelo piso, com difusores instalados em placas de piso elevado e nas estações de trabalho, que permitem flexibilidade e controle individual de vazão de ar. Neste trabalho foi feita a avaliação de sistema de condicionamento de ar com insuflamento pelo piso em um laboratório com condições controladas. O laboratório em que foram realizados os ensaios foi projetado e instalado com características similares àquelas de ambientes reais de edifícios de escritórios. Este fato, aliado à participação de usuários no processo de avaliação das condições de conforto térmico, tornaram possível a definição de parâmetros para a elaboração de projetos bem como para o estabelecimento de um modo eficaz de operação do sistema. O processo de avaliação das condições de conforto térmico no ambiente envolveu três etapas. Inicialmente, foram feitas medições das variáveis de conforto térmico no ambiente e de variáveis do sistema utilizando simuladores. Posteriormente, foi realizada a avaliação subjetiva do conforto térmico, com a substituição dos simuladores por pessoas no ambiente (usuários), nas mesmas condições da etapa anterior. Finalmente, foram feitas as medições das variáveis de conforto nas zonas de ocupação – micro climas – na condição de condicionamento individualizado, promovido por ajustes de vazão de ar e direcionamento do fluxo pelos usuários. Os resultados da avaliação permitem concluir que o sistema de condicionamento de ar com insuflamento pelo piso atende às expectativas para promover conforto térmico aos usuários de edifícios de escritórios com potencial de conservação de energia. / Since the introduction of the landscape office concept, the layout type and the internal loads distribution have changed significantly, requesting larger flexibility in the buildings. Besides, building performance evaluation applied to contemporary office buildings has shown that for most such buildings thermal comfort and air quality users level satisfaction is low. These facts are indicating that project concepts, operation and use of air conditioning systems need to be changed. In order to solve these problems, underfloor air supply is becoming a common practice also in Brazil. This system with floor and workstation diffusers allows flexibility and an individualized airflow control. In this work the evaluation of the underfloor air conditioning system was carried out in a laboratory facility with controlled conditions. The laboratory was designed and built up with similar characteristics to those of actual office buildings environments. This fact and the participation of users in the process of thermal comfort evaluation, made possible the definition of design parameters as well as the establishment of the system operation conditions in an effective way. The evaluation of the environment thermal comfort conditions was accomplished in three stages. Initially, measurements of thermal comfort and system variables were made using simulators. Later, in the same conditions of the previous stage, users (a sample of people) have evaluated, in a subjective way, the environment thermal comfort. Finally, measurements of the comfort variables were accomplished in the occupation areas - microclimates - in the condition of individualized conditioning, promoted by air flow adjustments and flow direction by the users. The results of the evaluation allow to conclude that the underfloor air conditioning system satisfies to the expectations to promote thermal comfort to the office building users with potential of energy conservation.
67

Sistema de ar condicionado com insuflamento pelo piso em ambientes de escritórios: avaliação do conforto térmico e condições de operação. / Underfloor air supply system applied to office buildings: thermal comfort and operational conditions evaluation.

Brenda Chaves Coelho Leite 06 March 2003 (has links)
Desde a introdução do conceito de escritório aberto, o tipo de ocupação e a distribuição das cargas internas têm sofrido grandes mudanças, requerendo maior flexibilidade nos edifícios. Além disto, avaliações de desempenho de edifícios de escritórios da atualidade têm apresentado resultados que são fortes indicadores da necessidade de mudanças de conceitos de projeto, operação e uso de sistemas de condicionamento de ar, devido ao elevado nível de insatisfação dos usuários quanto ao conforto e à qualidade do ar. Para tentar solucionar estes problemas, outro conceito em distribuição de ar, já em uso nos países desenvolvidos, está começando a ser adotado também no Brasil; trata-se de insuflamento pelo piso, com difusores instalados em placas de piso elevado e nas estações de trabalho, que permitem flexibilidade e controle individual de vazão de ar. Neste trabalho foi feita a avaliação de sistema de condicionamento de ar com insuflamento pelo piso em um laboratório com condições controladas. O laboratório em que foram realizados os ensaios foi projetado e instalado com características similares àquelas de ambientes reais de edifícios de escritórios. Este fato, aliado à participação de usuários no processo de avaliação das condições de conforto térmico, tornaram possível a definição de parâmetros para a elaboração de projetos bem como para o estabelecimento de um modo eficaz de operação do sistema. O processo de avaliação das condições de conforto térmico no ambiente envolveu três etapas. Inicialmente, foram feitas medições das variáveis de conforto térmico no ambiente e de variáveis do sistema utilizando simuladores. Posteriormente, foi realizada a avaliação subjetiva do conforto térmico, com a substituição dos simuladores por pessoas no ambiente (usuários), nas mesmas condições da etapa anterior. Finalmente, foram feitas as medições das variáveis de conforto nas zonas de ocupação – micro climas – na condição de condicionamento individualizado, promovido por ajustes de vazão de ar e direcionamento do fluxo pelos usuários. Os resultados da avaliação permitem concluir que o sistema de condicionamento de ar com insuflamento pelo piso atende às expectativas para promover conforto térmico aos usuários de edifícios de escritórios com potencial de conservação de energia. / Since the introduction of the landscape office concept, the layout type and the internal loads distribution have changed significantly, requesting larger flexibility in the buildings. Besides, building performance evaluation applied to contemporary office buildings has shown that for most such buildings thermal comfort and air quality users level satisfaction is low. These facts are indicating that project concepts, operation and use of air conditioning systems need to be changed. In order to solve these problems, underfloor air supply is becoming a common practice also in Brazil. This system with floor and workstation diffusers allows flexibility and an individualized airflow control. In this work the evaluation of the underfloor air conditioning system was carried out in a laboratory facility with controlled conditions. The laboratory was designed and built up with similar characteristics to those of actual office buildings environments. This fact and the participation of users in the process of thermal comfort evaluation, made possible the definition of design parameters as well as the establishment of the system operation conditions in an effective way. The evaluation of the environment thermal comfort conditions was accomplished in three stages. Initially, measurements of thermal comfort and system variables were made using simulators. Later, in the same conditions of the previous stage, users (a sample of people) have evaluated, in a subjective way, the environment thermal comfort. Finally, measurements of the comfort variables were accomplished in the occupation areas - microclimates - in the condition of individualized conditioning, promoted by air flow adjustments and flow direction by the users. The results of the evaluation allow to conclude that the underfloor air conditioning system satisfies to the expectations to promote thermal comfort to the office building users with potential of energy conservation.
68

Uso racional e eficiente de energia elétrica: metodologia para determinação dos potenciais de conservação dos usos finais em instalações de ensino e similares. / Methodology for determining the potential of electric energy conservation of electricity end uses in university buildings.

André Luiz Montero Alvarez 22 April 1998 (has links)
Este trabalho apresenta uma metodologia para a determinação do potencial de conservação de energia elétrica de usos finais, orientada para a análise de instalações de ensino, aplicável, também, a instalações comerciais em geral. Os usos finais considerados no trabalho são: iluminação, ar condicionado, microcomputadores pessoais e outros equipamentos elétricos. São apresentados procedimentos para o levantamento de dados e para a determinação do potencial de conservação de energia elétrica de cada uso final analisado, além de uma metodologia estatística para a análise de contas de energia elétrica. São definidos, também, indicadores do uso de energia elétrica bastante úteis em diagnósticos energéticos, permitindo estimar o potencial de conservação da instalação a partir da análise comparativa de seus índices com valores típicos obtidos em outros diagnósticos energéticos ou em publicações especializadas. A aplicação prática da metodologia é apresentada na forma de um estudo de caso, realizado em 1996 na Cidade Universitária Armando de Salles Oliveira - CUASO, o maior campus da Universidade de São Paulo – USP e um dos maiores do Brasil, localizado na cidade de São Paulo. Um volume considerável de informações é analisado e discutido em detalhes, fornecendo dados globais e desagregados em usos finais sobre as características de consumo e os potenciais de conservação de energia elétrica do campus. / This work presents a methodology for determining the potential of electric energy conservation of electricity end uses. The methodology is oriented to university premises, but it is also applicable to other types of installations. End uses considered in this work include lighting, air conditioning, personal computers and other electric devices. Procedures for data gathering and determination of conservation potential of each end use are presented. A statistical methodology for analyzing electricity bills is also presented. Furthermore, some useful indicators for energy diagnoses are developed. These indicators allow the estimation of the conservation potential of a given installation through comparison with typical values extracted from the other energy diagnoses or technical literature. The proposed methodology was applied in the main campus of University of São Paulo – USP, one of the largest in Brazil with some 30,000 undergraduate students. A large amount of data is analyzed and discussed, yielding global and specific indicators regarding end use characteristics and conservation potential within the campus.
69

Iluminação natural em projetos de escolas: uma proposta de metodologia para melhorar a qualidade da iluminação e conservar energia / Daylighting in schools projects: a proposition of a methodology to enhance lighting quality and energy savings.

Dimas Bertolotti 18 April 2007 (has links)
Este trabalho tem como objetivo analisar estratégias de iluminação natural utilizadas nos estágios iniciais do projeto de arquitetura capazes de aumentar a qualidade da iluminação e a conservação de energia nos edifícios escolares. Essas estratégias têm sido aplicadas com sucesso em edifícios escolares em vários países, melhorando o desempenho e o bem-estar dos estudantes e conservando energia. Entre essas estratégias, o autor selecionou um dispositivo zenital para iluminação natural com seleção angular e difusores opacos, realizou um ensaio experimental em um modelo físico reduzido de uma sala de aula padrão, sob condições de céu real e analisou comparativamente os resultados. O estudo mostrou que a adoção de uma metodologia para utilizar estratégias como a analisada neste trabalho pode conseguir um adequado controle da radiação solar para evitar a incidência direta da luz do Sol, evitar o ofuscamento e o aquecimento excessivo de ambientes de salas de aula em climas quentes e, ao mesmo tempo, aproveitar a iluminação natural, tanto difusa quanto direta refletida, para obter maior conforto visual e economizar energia. / This work aims to analyse daylighting strategies applied in early stages of architectural design as to improve lighting quality and energy savings in school buildings. Similar strategies have already been successfully applied in many countries around the world, enhancing student?s performance and well being while helping to save energy. Among the strategies studied, the author describes an experiment under real sky conditions using a physical scale model of a standard classroom equipped with a roof monitor combined with an overhang and interior vertical diffusing baffles as a way to check its influence in interior lighting conditions. The experiment has shown that the use of daylighting strategies can promote an adequate control of solar radiation, avoiding direct sunlight penetration inside the classrooms, limiting glare problems and excessive heat of hot climates. At the same time, such strategies optimise both direct and defuse use of daylight to improve visual comfort and energy savings.
70

Abordagem sustentável da luz natural: análise do desenho de vãos e eficiência dos vedos translúcidos e transparentes em edifícios das cidades de São Paulo, Berlim e Frankfurt am Main durante as últimas décadas do século XX e primeira década do século XXI

Figueiredo, Erika Ciconelli de 09 August 2011 (has links)
Made available in DSpace on 2016-03-15T19:21:34Z (GMT). No. of bitstreams: 1 Erika Ciconelli de Figueiredo.pdf: 19944207 bytes, checksum: a41457dbf4fa5d2e118844c77234cf6e (MD5) Previous issue date: 2011-08-09 / Fundação de Amparo a Pesquisa do Estado de São Paulo / This work has as goal to study the resultant daylight from International Style buildings openings in São Paulo, in Avenida Paulista and Berrini axis, analyzing illuminance distribution. The approach was done from the solar geometry and glass types point of view. The use of daylight and natural ventilation in buildings has always been part of architects challenges, nevertheless with the beginning of energetic crises during the 1970s, these issues became more important. However the concern with energy saving and use of natural resources are not usually demonstrated in the finished building. As São Paulo has a subtropical climate, the biggest concern is to avoid buildings inner heat, and the typical solution is the use of solar control glasses to reduce costs with air conditioning. Nevertheless even high performance glasses block a substantial part of daylight, beyond the heat. The compensation for low interior luminousness is done by artificial means, increasing unnecessarily buildings use and maintenance costs. Buildings from São Paulo, Brazil, Berlin and Frankfurt, Germany, were studied with local measurement and with floor modeling in Relux Professional 2010. Daylight distribution characteristics of each building were identified with the purpose of delineating potential projects improvements, focusing São Paulo daylight availability throughout the year The analysis results showed that international style façades have limitations to increase the use of daylight since the whole shell has a single treatment. Both in German and Brazilian buildings the daylight distribution followed a trendline, indicating the need of using other means to obtain illuminance levels with fewer variations between room endings / Este trabalho tem por finalidade estudar a luz natural resultante dos vãos dos edifícios de Estilo Internacional da cidade de São Paulo, nos eixos da Avenida Paulista e Avenida Engenheiro Luís Carlos Berrini, analisando a distribuição da iluminância. A abordagem foi feita do ponto de vista da geometria da insolação e dos tipos de vidros. O uso da iluminação e ventilação natural em edifícios sempre fez parte dos desafios enfrentados por arquitetos; no entanto, com o início da crise energética, na década de 70, essas questões ganharam maior importância. Contudo, a preocupação com a economia de energia e o uso de recursos naturais nem sempre se traduzem na obra finalizada. Como São Paulo é uma cidade de clima subtropical, a preocupação maior acaba sendo evitar o aquecimento interno dos edifícios, e a solução mais comum é o uso de vidros de controle solar para redução de gastos com ar-condicionado. Mesmo em vidros de alto desempenho, há o bloqueio de parte considerável da luz natural, além do calor. A compensação para a baixa luminosidade no interior do edifício se faz por meio da iluminação artificial, o que eleva desnecessariamente o custo do uso e da manutenção do edifício. Foram estudados edifícios de escritórios das cidades de São Paulo, no Brasil, Berlim e Frankfurt am Main, na Alemanha, com medições in loco e por meio da modelagem de pavimentos no programa Relux Professional 2010. As caracterísitcas da distribuição da luz natural de cada edifício foram identificadas com o objetivo de delinear possíveis melhorias projetuais, tendo em vista a disponibilidade de luz natural em São Paulo o ano todo. Os resultados das análises mostraram que as fachadas de modelo internacional apresentam limitações para aumentar o uso da luz natural por terem uma única solução plástica em toda a sua extensão. Tanto nos edifícios brasileiros como nos alemães, a distribuição luminosa acompanhou a mesma linha de tendência, indicando a necessidade de utilizar outros meios para obter níveis de iluminâncias internas com variações menores entre os extremos dos ambientes

Page generated in 0.1119 seconds